Preview only show first 10 pages with watermark. For full document please download

Ht Caltek Asia Limited

   EMBED


Share

Transcript

HT CALTEK ASIA LIMITED HT26 Multipurpose 3 3/4 Digits Digital Multimeter HT26 is a general purpose DMM, thanks its wide range of functions it is suitable for both electrical and electronics fields. Fountains Accessories • • • • • • • • • • • Test lead • Instruction manual • Battery • Carrying case AC Voltage DC Voltage AC Current up to 10A DC Current up to 10A Resistance Capacitance Frequency Duty Cycle Diode test Continuity buzzer Standards EN 61010-1 Due to our policy of continual product development we reserve the right to amend the specifications of all mentioned products without notice. HT26_PS_v01 Created on 12/2/2005 2:35:30 PM Prepared by Fung Page 1 of 4 HT CALTEK ASIA LIMITED 1. TECHNICAL SPECIFICATIONS The accuracy is indicated as [% of reading + number of digits]. It is referred to the following environmental conditions: temperature 23°C ± 5°C, relative humidity < 75%. DC VOLTAGE MEASUREMENT Range Resolution Accuracy 400mV 4V 40V 400V 600V 0.1mV 0.001V 0.01V 0.1V 1V ±(0.8%rdg + 2dgt) Input Impedance Protection Against Overload 10MΩ 600V DC/AC rms ±(0.8%rdg + 3dgt) AC Voltage Measurement Range Resolution Accuracy Frequency Range Input Impedance Protection Against Overload 4V 40V 400V 600V 0.001V 0.01V 0.1V 1V ±(1.2%rdg + 3dgt) 40~400Hz 10MΩ 600V DC/AC rms Accuracy (*) ±(1.2%rdg + 5dgt) Voltage drop 200mV DC Current Measurement Range Resolution 10A 0.01A Protection Against Overload Fuse 10A/600V (*) Accuracy is guaranteed for current up to: 6A continuous measurement, 7A 3 minutes uninterrupted measurement, up to 10A 2 minutes uninterrupted measurement. AC Current Measurement (*) Range Resolution Accuracy (**) 10A 0.01A ±(2.0%rdg + 5dgt) Voltage Drop 200mV Frequency Range 40 - 400 Hz. Protection Against Overload Fuse 10A/600V (**) Accuracy is guaranteed for current up to: 6A continuous measurement, 7A 3 minutes uninterrupted measurement, up to 10A 2 minutes uninterrupted measurement. Resistance Measurement Range Resolution 400Ω 0.1Ω 4kΩ 0.001kΩ 40kΩ 0.01kΩ 400kΩ 0.1kΩ 4MΩ 0.001MΩ 40MΩ 0.01MΩ Accuracy ±(1.0%rdg + 2dgt) Max Open Circuit Voltage Protection Against Overload <700mV 600VDC/ACrms<30sec ±(2.0%rdg + 2dgt) Due to our policy of continual product development we reserve the right to amend the specifications of all mentioned products without notice. HT26_PS_v01 Created on 12/2/2005 2:35:30 PM Prepared by Fung Page 2 of 4 HT CALTEK ASIA LIMITED Diode Test Forward voltage drop 0 – 1.000V Range Test Current Max Open Circuit Voltage Protection Against Overload Approx. 0.6mA 1.5V 600V DC/ACrms <30sec Continuity Test Range Sound level Test Current ≤50Ω Approx. 1mA Frequency Measurement Range Resolution 9.999Hz 0.001Hz 99.99Hz 0.01Hz 999.9Hz 0.1Hz 9.999kHz 1Hz 99.99kHz 10Hz Max Open Circuit Voltage Approx. 0.5V Protection Against Overload 600V DC/ACrms <30sec Accuracy Protection Against Overload ±(1.5%Reading + 5dgt) 600V DC/ACrms <30sec Accuracy ±(3.5%Reading + 5dgt) Protection Against Overload 600V DC/ACrms <30sec Note: Never exceed voltage limits listed below. Duty Cycle Measurement Range Resolution 20 - 80% 0.1% Note: Never exceed voltage limits listed below. Frequency and Duty Cycle measurements’ voltage limits Working voltage VMIN ≥ 1.5Vp-p VMAX ≤ 400Vrms VMIN ≥ 1.5Vp-p VMAX ≤ 10Vp-p VMIN ≥ 3.0Vp-p VMAX ≤ 10Vp-p Capacitance Measurement Range Resolution 5nF 0.001nF 50nF 0.01nF 500nF 0.1nF 5uF 0.001uF 50uF 0.01uF 100uF 0.1uF(30sec) Accuracy ±(8.0%rdg + 25dgt) ± (4.0%Read. + 5dgt) Frequency 0 – 400Hz 400 – 900Hz 900Hz – 10kHz Protection Against Overload 600V DC/ACrms <30sec Due to our policy of continual product development we reserve the right to amend the specifications of all mentioned products without notice. HT26_PS_v01 Created on 12/2/2005 2:35:30 PM Prepared by Fung Page 3 of 4 HT CALTEK ASIA LIMITED 2. GENERAL SPECIFICATIONS SAFETY The instrument complies with: EN 61010-1 Insulation: Class 2, Double insulation Pollution degree: 2 Over voltage category: CAT III 600V For inside use, max height: 2000m GENERAL DATA Mechanical characteristics Dimensions: 70(L) x 144(W) x 40(H) mm Weight (including batteries): Approximate 280g POWER SUPPLY Batteries type: 2 batteries x 1.5V AAA UM4 Indication of low batteries: The symbol " " is displayed when batteries voltage are too low. Batteries life: Approx. 170 hours. DISPLAY Specifications: 3 ¾ LCD with max. reading 3999 counts + symbol and decimal point. ENVIRONMENT Environmental conditions Reference temperature: 23° ± 5°C Working temperature: -5 - 40 °C Relative humidity: <70% Storage temperature: -10 ~ 60 °C Storage humidity: <70% EMC and LVD This instrument is designed and tested complies with the requirements of the European EMC Directive 89/336/EEC and in accordance with Low Voltage Directive 73/23/EEC, EN publication 61010-1, pollution degree 2 and installation category (over voltage category) III 600V. HT CALTEK ASIA LIMITED Address : Flat E , 12/F , Effort Industrial Building 2-8 Kung Yip Street, Kwai Chung, N.T. , Hong Kong Tel : 852 – 2401 1222 Fax : 852-2420 3472 Email : [email protected] http://www.htcaltek.com/ Due to our policy of continual product development we reserve the right to amend the specifications of all mentioned products without notice. HT26_PS_v01 Created on 12/2/2005 2:35:30 PM Prepared by Fung Page 4 of 4