Huawei Data Center NetHos Cabinet
HUAWEI TECHNOLOGIES CO., LTD.
For nearly 20 years, based on a deep understanding of cabinets, Huawei launched NetHos Cabinets, providing a necessary foundation for physical data center, and a suitable environment for the equipment, with features of efficient cooling,perfect cabling management, flexible, simple installation, compatibility, high reliability, high security and so on, which are widely used in various types of data centers.
New NetHos Cabinets
Safe & Reliable Cabinets comply with IEC 60297-2 standard. The distance between the front and the rear mounting bars is adjustable, providing a reasonable installation layout of various types of system equipment.
Stable Structure Design Static load is no less than 1200kg, to ensure stability of cabinets.
Leading heat dissipation Super mesh door, ventilation rate is no less than 70 %, to ensure the smooth flow of hot and cold air.
Good compatibility Standardized design, compatible with 19-inch rack equipment from different mainstream manufacturers.
simply Expansion Using a dedicated Cabinets connections,which support with side panels and without side panels mounted side by side.
Professional distribution solutions Professional cabinet-level power system, providing various types of power distribution solutions.
Perfect cable management Trough at the top of the innovation, supporting top and bottom outlet, facilitate field wiring.
1
New NetHos Cabinets
Safe and reliable structural design, to meet a variety of IT applications • Using steel design, to meet a variety of high-density server deployments, provide reliable load. • Micro- environmental management,providing equipment with a comfortable operating environment with temperature control design.
Unified architecture platform to facilitate installation and maintenance • unified Server and cabling cabinets, distribution cabinets, air condition structure architecture, engineering interface for easy installation and maintenance. • Without Tools design, without too much space installation requirements, easy deployment and installation. • Compatible with other mainstream manufacturers standard equipment, high-density server rack deployment.
Rich and optional cabinet accessories, to ensure cabinet convenient to use • Professional cabinet-level power system to provide various types of power distribution solutions. • Cable and hardware installation accessories, used on demand to facilitate the management and operation. • A variety of wind components to ensure smooth flow of hot and cold air.
Cabinet - level access control to ensure high security • Support electronic door locks (induction credit card), while supporting the mechanical emergency unlocking. • Support centralized monitoring and off-line run independently, to realize intelligent monitoring.
2
Technical Specification
Item
Technical parameters
model
FR42612
FR47612
FR42611
FR42812
dimension (W*D*H)
600*1200*2000
600*1200*2200
600*1100*2000
800*1200*2000
installation space per cabinet
42U
47U
42U
42U
Roller
Y
N
Y
Y
Air
Front and rear air duct structure, door ventilation rate is 70%.
door structure
Front single door and rear double doors
surface
Surface powder thickness should be no less than 60 μm, meeting the requirements of Class A environment.
material
Made of high-intensity class A carbon cold rolled steel sheet and zinc-coated steel sheet with thickness of 1mm~2mm
Protection Level
IP20
Environmental standards
Meet the ROHS standards
Front and rear door opening angle
120º
Note: can be customized according to the specific needs of the customer.
3
Cabinet PDU
From the performance: Basic PDU&monitoring PDU
type
4
model
Voltage
Electric current (A)
Capacity (KVA)
Configuration
Mounting direction
Basic
PDU16-1PH-9/0-B
220V Single-phase
16
3.5
9 C13 socket, without open space
1U
Basic
PDU16-1PH-7-B
220V Single-phase
16
3.5
7 international socket, 7 * 6A fuse protection
1U
Basic
PDU16-3PH-24/6-B
380V Three-phase
16
11
3×(8 C13+2 C19), without open space
0U
Basic
PDU16-1PH-5-B
220V Single-phase
16
3.5
5 C13, 5*10A fuse protection
1U
Basic
PDU30-3PH-18/3-B
208V Three-phase
30
9
3×(6 C13+1 C19), 3*16A/2P open space
0U
Basic
PDU32-1PH-20/4-B
220V Single-phase
32
7.3
2×(10 C13+2 C19), 2*16A/1Popen space
0U
Basic
PDU16-3PH-24/6-B
380V Three-phase
16
11
3×(8 C13+2 C19), without open space
0U
Basic
PDU63-1PH-16/9-B
220V Single-phase
63
12.6
2×(4 C13+2 C19) +2×(3 C13+3 C19), 4*16A/1P open space
0U
Cabinet PDU
From the installation: full height PDU & half height PDU & in-cabinet PDU
type
Basic
model
PDU32-1PH-9/4-B
Voltage
220V Single-phase
Electric current (A)
32
Electric current (A)
Capacity (KVA)
7.3
Capacity (KVA)
Configuration
2×(5个C13+2个C19), 2*16A/1Popen space
Configuration
Mounting direction
half height
Mounting direction
type
model
Voltage
monitoring
PDU32-1PH-20/4-M
220V Single-phase
32
7.3
2×(10 C13+2 C19), 2*16A/1Popen space
0U
monitoring
PDU16-3PH-24/6-M
380V Three-phase
16
11
3×(8 C13+2 C19), without open space
0U
monitoring
PDU32-3PH-6/12-M
380V Three-phase
32
22
6×(1 C13+2 C19), 6*16A/1P Magnetic open space
0U
5
Cabinet Rack
Front door
NO.1
2m / 2.2m Mesh door
Applies to forward wind, after the wind air scenes, to meet cabinet with high ventilation rate.
Type
NO.2
Dimensions (W*D*H/mm)
Weight (kg)
Color
2m Mesh door
594*22*1927
8.2
black
2.2m Mesh door
594*22*2177
8.6
black
2m / 2.2m Access control door
Access control doors have electric locks with the access control function.
Type
6
Dimensions (W*D*H/mm)
Weight (kg)
Color
2m Access control door
594*22*1927
8.5
black
2.2m Access control door
594*22*2177
9.1
black
Cabinet Rack
Front door
NO.3
2.2m Glass door
Glass doors have high sealing performance and can meet requirements of underfloor air supply scenarios.
Type
2.2m Glass door
Dimensions (W*D*H/mm)
594*22*2177
Weight (kg)
20
Color
black
Side Panel Side panels are installed inside the cabinet to seal cabinet sides and prevent dust. Side panels can be configured based on requirements.
Type
Dimensions (W*H/mm)
Weight (kg)
Color
2m side panel
1110*800
7.5
black
2.2m side panel
1110*920
8.4
black
7
Cabinet Rack
Bottom Plate There are two types of bottom plates: Front air supply bottom plate and Underfloor air supply bottom plate.
NO.1
Front air supply bottom plate
It applies to front air supply scenarios. It ensures the sealing between the mounting bars in the front and the foreside of the cabinet for air flow isolation.
Dimensions (W*D*H/mm)
567*235* 9
NO.2
Applicable cabinet Model (W*D*H) 600*1200*2000 600*1200*2200
Weight (kg)
1.22
Underfloor air supply bottom plate
It uses a removable structure and applies to common precision air supply, and full enclosure scenarios.
Dimensions (W*D*H/mm)
600*1100*30
NO.3
Applicable cabinet Model (W*D*H) 600*1200*2000 600*1200*2200
Weight (kg)
8.4
Intelligent precision air supply bottom plate
Intelligent precision air supply bottom plate is mainly used for under floor air scene, used with air deflector, air damper.
Dimensions (W*D*H/mm)
600*1100*30
8
Applicable cabinet Model (W*D*H) 600*1200*2000 600*1200*2200
Weight (kg)
7.0
Hardware Installation
Tray Cabinet tray is mainly used to load equipment, divided into fixed tray and adjustable tray.
NO.1
fixed tray
A fixed try is used to facilitate device installation and placement. It supports standard devices, can bear a weight of 100 kg.
Dimensions (W*D*H/mm)
Weight (kg)
483*622*62
NO.2
Load capacity (kg)
3.37
100
adjustable tray
Adjustable tray used to load equipment, according to the square hole depth adjustment.
Dimensions (W*D*H/mm)
481*870*43.6
Weight (kg)
5.6
Load capacity (kg)
100
Depth range (mm)
570~870
Rail L - shaped guide rail for both sides of the cabinet, a standard design, can withstand the fixed guide mobile device or equipment. Dimensions (W*D*H/mm)
42*622*37
Weight (kg)
0.72
Load capacity (kg)
50
Depth range (mm)
645~720
9
Hardware Installation
PDU Mounting Plate The PDU mounting plate support PDU installation. The cabinet supports PDU screw installation and without-tool mounting. PDU mounting plate including full-height and half-height PDU mounting plate.
NO.1
full-height PDU mounting plate
It is used for the installation of full height PDUs. Full height PDUs are clamped onto the mounting plates or secured to the plates by using screws, making the installation simple and easy. Both 2 m and 2.2 m full height PDU mounting plates use a segmental structure.
Type
Dimensions (W*H/mm)
Structure Model
Weight (kg)
Upper segment / Lower segment: 125*200
Upper-lower twosegment
0.537
Upper segment / Lower segment: 125*50
Upper-lower twosegment
1.09
Full height PDU mounting plate
NO.2
half-height PDU mounting plate
It is used for the installation of half height PDUs. Half height PDUs are clamped onto the mounting plates or secured to the plates by using screws. 2.0 m mounting plates use a unitary design and support the installation of vertical cabling modules. 2.2 m mounting plates use a three-segment design.
Type 2.0 m half height PDU mounting plate
Type
2.2 m half height PDU mounting plate
10
Dimensions (W*H/mm)
125*1900
Dimensions (W*H/mm) Upper segment: 125*350 Middle segment: 125*450 Lower segment: 125*300
Structure Model
Unitary
Weight (kg)
2.89
Structure Model
Upper-middle-lower three-segment
Weight (kg)
1.5
Cable Management
Cabling Unit Cabinet horizontal cabling management, and a decorative tool.
Dimensions (W*D*H/mm)
482.6 *91 *43.6
Weight (kg)
0.56
Trace amount
48 *6 square thread
Space Occupied
1U
Cable Ring A cable fastener is installed on a vertical column in the cabinet for vertical-cable management.
Dimensions (W*D*H/mm)
48 *188.6 *50
Weight (kg)
0.163
11
Cable Management
Depth-directed Cable Manager A depth-directed cable manager is used for depth-directed cabling. Its drawer design supports various mounting bar distances.
Dimensions (W*H)
50*36
Weight (kg)
0.537
Depth range (mm)
442.5~742.5
Cabling Tray A cabling tray is used for forward and backward cabling. It uses unique mounting ears to facilitate device installation.
Dimensions (W*D*H)
482.6*250*43.6
12
Weight (kg)
1.89
Space Occupied
1U
Airflow Management
Dummy Panel If certain space in the cabinet is not occupied, install filler panels in that position to prevent wind and beautify the cabinet.
NO.1
1U dummy panel
1 U dummy panel occupied by 1U space.
Type
1U dummy Panel
NO.1
Dimensions (W*D*H)
482.6*25*44
Weight(kg)
0.12
2U dummy panel
2 U dummy panel occupied by 2U space.
Type
2U dummy Panel
Dimensions (W*D*H)
482.6*25*88.5
Weight (kg)
0.216
"L" Airtight Bar “L” Airtight Bar is used for sealing.
Type
“L”Airtight Bar
Dimensions (W*D*H)
598.5 *10*72.5
Weight (kg)
0.656
13
Airflow Management
Air Deflector Air deflectors apply to underfloor air supply scenarios. Cabinet air deflectors are classified into the following two types based on air supply modes: Common precision air supply air deflector & Intelligent precision air supply air deflector.
NO.1
Common precision air supply air deflector
It applies to common precision air supply scenarios and used with an underfloor air supply bottom plate.
Dimensions (W*D*H)
482.6*332*138
NO.2
Weight (kg)
2.4
Space Occupied
3U
Intelligent precision air supply air deflector
It applies to intelligent precision air supply scenarios and used with an air valve and an underfloor air supply bottom plate.
Dimensions (W*D*H)
442*709.5*130.6
NO.3
Weight (kg)
4.26
Space Occupied
3U
Air damper
Air damper used with intelligent precision air supply air deflector, realize intelligent precision air supply.
Dimensions (W*D*H/mm)
442*650*86
14
Input Voltage (V DC)
24
Operating Temperature (ºC)
5~40
Other Unit
Cabinet Bracket Cabinets supporting bracket for the booster and the supporting cabinet.
width (mm)
600
Applicable anti-static floor height (mm)
depth (mm)
1200
600
Copper Ground Bar A copper ground bar is used for the grounding of devices inside the cabinet. There are M6 and M8 terminals on a copper bar. M6 terminal ports are used for device grounding, and M8 for leading out ground cables. Insulators can be used to isolate the copper bar from the cabinet to ensure high grounding reliability. Users can configure insulators as required. Dimensions (W*D*H)
Installation Mode
It can be horizontally installed on mounting bars.
490*3*30
Number of Terminals
19*M6+2*M8
Door Status Sensor A door status sensor can be installed on the front door or rear door of the cabinet. It generates an alarm when detecting abnormal cabinet door status. Door status sensors can be configured based on customers' requirements. Rated current (mA)
Rated power (W)
500
10
Securing mode
Screw
Switch form
Normally open
color
White acrylonitrile butadiene styrene (ABS) engineering plastic
15
Other Unit
Lighting System Fittings Lighting System Fitting achieves cabinet lighting. Light system fittings include a daylight lamp and a touch switch.
NO.1 Daylight Lamp LED lamps are used for lighting in the cabinet. Each server is configured with two LED lamps on the top at the two ends of the cabinet.
Installation mode
Securing mode
Roof-mounted or wallmounted
With buckles (delivered with the lamp)
Power (W)
2~6
Service life (h)
≥10000
NO.2 Touch Switch A touch switch automatically turns on the daylight lamp when detecting that cabinet doors are open and turns it off when the doors are closed. It uses advanced NC contacts with high sensitivity.
Rated working voltage (V)
220
16
Rated working current (A)
10
Installation mode
Mechanical screw installation, such as surface mounting technology (SMT) and add-in)
Service life (times)
100000
Applications
CMCC Southern Base IDC
Venezuela CANTV Data Center
Shanghai Telecom Data Center
17
About Network Energy of Huawei Based on the deep understanding about telecommunication in a long term of 20 years, and the construction and maintenance experience of more than 1.5 million global telecommunication sites, Huawei network energy product line adheres the ‘4S’ concepts of ‘Simple, Scalable, Smart, Saving’, and commits to providing customers the world's leading network energy solutions. The network energy product line has two main businesses of site energy and data center energy. We are making stable, green energy and infrastructure for customers in ICT field, building a solid foundation for excellence networks, protecting customers’ long term investment on energy and infrastructure.
About Huawei Huawei is a leading global ICT solutions provider. Through our dedication to customer-centric innovation and strong partnerships, we have established end-to-end capabilities and strengths across the carrier networks, enterprise, consumer, and cloud computing fields. We are committed to creating maximum value for telecom carriers, enterprises and consumers by providing competitive ICT solutions and services. Our products and solutions have been deployed in over 140 countries, serving more than one third of the world's population.
Copyright © Huawei Technologies Co., Ltd. 2013. All rights reserved. General Disclaimer The information in this document may contain predictive statements including, without limitation, statements regarding the future financial and operating results, future product portfolio, new technology, etc. There are a number of factors that could cause actual results and developments to differ materially from those expressed or implied in the predictive statements. Therefore, such information is provided for reference purpose only and constitutes neither an offer nor an acceptance. Huawei may change the information at any time without notice.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Industrial Base Bantian Longgang Shenzhen 518129, P.R. China Tel: +86-755-28780808 Version No.: M3-035748-20130530-C-2.0 www.huawei.com