Transcript
HV reed relays K-551H, K-552H K-553H, K-554H, K-555H form A contact (normally open)
PIT-RADWAR S.A. WROCLAW DIVISION
for PCBs
50-425 Wrocław, ul. Krakowska 64, Poland tel. (+48) 71/342-65-54, fax (+48) 71/342-58-59 e-mail:
[email protected] www.dolam.pl
This product is in accordance with RoHs TYPE
PARAMETERS
Unit
K-551H
K-552H
K-553H
K-554H
K-555H
1.CONTACT PARAMETERS Switching power
max
W, VA
Breakdown voltage Switching voltage (DC or AC PEAK)
min max
kV D C kV
Switching current
max
A
Initial contact resistance
max
m
Life expectancy Load 1 5 kVD C, Load 2 7,5 kVD C , Load 3 10 kV DC ,
50 7 5
10
10 7,5
14 10
17
18 12
2
1 150 operations
0,5x10 6
1 mA 1 mA 1 mA
0,5x106 0,5x106
0,5x106
2. COIL PARAMETERS Nominal voltage
VD C
5/6/12/24
Pull-in voltage
max
VD C
4/4,5/9/18
Drop-out voltage
min
VD C
0,5/0,6/1/2
Coil resistance
±10%
45/45/180/650
Insulation resistance (at 1000VD C )
min
Operate time including bounces
max
ms
3,6
Release time
max
ms
0,5
Breakdown voltage coil-contact
min
kV D C
3. RELAY PARAMETERS 101 0 (at 70°C)
101 2 (at 20°C)
15
30
Environment category acc. to IEC 68-2-1÷3
40/85/21
4. DIMENSIONS AND TERMINAL ARRANGEMENTS all dimensions in mm 63.5
4x 1.6 12.7
4
1 3
4 2
2
100 min
~5 17.4 max
No 6/02.2017
58
19.5 max
4.0 max
1 min
70.8 max
2x 1 12.7
4.5
1
3
0,5x106
HV reed relays K-555S form A contact (normally open) PIT-RADWAR S.A.
for PCBs
WROCLAW DIVISION 50-425 Wrocław, ul. Krakowska 64, Poland tel. (+48) 71/342-65-54, fax (+48) 71/342-58-59 e-mail:
[email protected] www.dolam.pl
This product is in accordance with RoHs
TYPE
PARAMETERS
Unit
K-556S
1.CONTACT PARAMETERS Switching power
max
W, VA
10
Breakdown voltage
min
kV D C
19
Switching voltage (DC or AC PEAK)
max
kV
12
Switching current
max
A
1
Initial contact resistance
max
m
150
Life expectancy Load 3
operations 10 kV DC ,
6
1 mA
0,5x10
2. COIL PARAMETERS Nominal voltage
VD C
24
Pull-in voltage
max
VD C
18
Drop-out voltage
min
VD C
2
Coil resistance
±10%
400
Ins ulation resistance (at 1000VD C )
min
Operate time including bounces
max
ms
3,6
Release time
max
ms
0,5
Breakdown voltage coil-contact
min
kV D C
30
3. RELAY PARAMETERS 101 0 (at 70°C)
Environment category acc. to IEC 68-2-1÷3
101 2 (at 20°C)
40/85/21
4. DIMENSIONS AND TERMINAL ARRANGEMENTS all dimensions in mm 63.5
4x 1.6 12.7
4
1 3
4 2
2
100 min
~5 17.4 max
No 1/03.2011
58
19.5 max
4.0 max
1 min
70.8 max
2x 1 12.7
4.5
1
3
HV reed relays K-561H, K-562H form A contact (normally open) for PCBs
PIT-RADWAR S.A. WROCLAW DIVISION 50-425 Wrocław, ul. Krakowska 64, Poland tel. (+48) 71/342-65-54, fax (+48) 71/342-58-59 e-mail:
[email protected] www.dolam.pl
This product is in accordance with RoHs TYPE
PARAMETERS
Unit
K-561H
K-562H
1.CONTACT PARAMETERS Switching power
max
W, VA
50
Breakdown voltage
min
kVDC
7
10
Switching voltage (DC or AC PEAK)
max
kV
5
7,5
Switching current
max
A
2
Initial contact resistance
max
m
150
Life expectancy
operations 6
Load 1
5 kVDC,
1 mA
0,5x10
Load 2
7,5 kVDC,
1 mA
0,5x10
6
2. COIL PARAMETERS Nominal voltage
VDC
5
6
12
24
5
6
12
24
Pull-in voltage
max
VDC
4
4,5
9
18
4
4,5
9
18
Drop-out voltage
min
VDC
0,5
0,6
1
2
0,5
0,6
1
2
Coil resistance
±10%
45
45
180
650
45
45
180
650
Insulation resistance (at 1000VDC)
min
Operate time including bounces
max
ms
3,6
Release time
max
ms
0,5
Breakdown voltage coil-contact
min
kVDC
15
3. RELAY PARAMETERS 10
12
10 (at 70°C)
Environment category acc. to IEC 68-2-1÷3
10 (at 20°C)
40/85/21
4. DIMENSIONS AND TERMINAL ARRANGEMENTS all dimensions in mm
1
3
4
12.7
63.5 1 3
2
4 2
53.3
70.8 max
No 7/01.2007
4x 1 58
12.7
4.5
1min
19.5 max
17.4 max
HV red relays R-561,R-562 form A contact (normally open) for PCBs
PIT-RADWAR S.A. WROCLAW DIVISION 50-425 Wrocław, ul. Krakowska 64, Poland tel. (+48) 71/342-65-54, fax (+48) 71/342-58-59 e-mail:
[email protected] www.dolam.pl
PARAMETERS
This product is in accordance with RoHs
TYPE
Unit
R-561
R-562
1. CONTACT PARAMETERS Switching power
max
W,VA
50
Breakdown voltage
min
kVDC
7
10
Switching voltage (DC or AC PEAK)
max
kV
5
7,5
Switching current
max
A
2
Initial contact resistance
max
m
150 operations
Life expectancy 6
0,5x10
Load 1 5 kVDC, 1 mA Load 2 7,5 kVDC, 1 mA
6
0,5x10
2. COIL PARAMETERS Nominal voltage
VDC
5
6
12
24
5
6
12
24
Pull-in voltage
max
VDC
4
4,5
9
18
4
4,5
9
18
Drop-out voltage
min
VDC
0,5
0,6
1
2
0,5
0,6
1
2
Coil resistance
±10%
45
45
180
650
45
45
180
650
Insulation resistance (at 1000VDC)
min
o
10 (at 20 C)
Operate time including bounces
max
ms
3,6
Release time
max
ms
0,5
Breakdown voltage coil-contact
min
kVDC
15
3. RELAY PARAMETERS 10
12
10 (at 70 C)
Environment category acc. to IEC 68-2-1÷3
o
40/85/21
4. DIMENSIONS AND TERMINAL ARRANGEMENTS 53.3
all dimensions in mm 1
3
1
3
4
4 2
2
17 max
17,8 max
65 max
12,7 No 5/04.2009
4.5
4x1
HV reed relays K-561B, K-562B form B contact (normally closed) for PCBs
PIT-RADWAR S.A. WROCLAW DIVISION 50-425 Wrocław, ul. Krakowska 64, Poland tel. (+48) 71/342-65-54, fax (+48) 71/342-58-59 e-mail:
[email protected] www.dolam.pl
This product is in accordance with RoHs TYPE
PARAMETERS
Unit
K-561B
K-562B
1.CONTACT PARAMETERS Switching power
max
W, VA
50
Breakdown voltage
min
kVDC
7
10
Switching voltage (DC or AC PEAK)
max
kV
5
7,5
Switching current
max
A
2
Initial contact resistance
max
m
150
Life expectancy
operations
Load 1
5 kVDC,
1 mA
Load 2
7,5 kVDC,
1 mA
6
0,5x10
6
0,5x10
2. COIL PARAMETERS Min
Nom
Max
12/24
16/30
Coil voltage*
VDC
Pull-in voltage
VDC
2/4
9/18
Drop-out voltage
VDC
1,9/3,9
8,9/17,9
±10%
225/900
Insulation resistance (at 1000VDC)
min
10
Operate time
max
ms
2,6
Release time including bounces
max
ms
3,6
Breakdown voltage coil-contact
min
kVDC
Coil resistance
250/1000
3. RELAY PARAMETERS 11
15
Environment category acc. to IEC 68-2-1÷3
40/85/21
4. DIMENSIONS AND TERMINAL ARRANGEMENTS all dimensions in mm
53.3 2
2
2
3
3
4 1
4 1
+12V/24V
63 max
19 max
24,5 max
17.8
*Coil polarity must be observed. See drawing for the positive pin. Relays are susceptible to magnetic interaction due to bias internal magnet. No 5/08.2006
4.5
4x 1
275/1100
HV reed relays K-551B, K-552B form B contact (normally closed) PIT-RADWAR S.A.
for PCBs
WROCLAW DIVISION 50-425 Wrocław, ul. Krakowska 64, Poland tel. (+48) 71/342-65-54, fax (+48) 71/342-58-59 e-mail:
[email protected] www.dolam.pl
This product is in accordance with RoHs
TYPE
PARAMETERS
Unit
K-551B
K-552B
1.CONTACT PARAMETERS Switching power
max
W, VA
50
Breakdown voltage
min
kVDC
7
10
Switching voltage (DC or AC PEAK)
max
kV
5
7,5
Switching current
max
A
2
Initial contact resistance
max
m
150
Life expectancy
operations
Load 1 Load 2
5 kVD C, 7,5 kV DC,
6
1 mA 1 mA
0,5x10
0,5x10
6
2. COIL PARAMETERS Min
Nom
Max
12/24
16/30
Coil voltage*
VDC
Pull-in voltage
VDC
Drop-out voltage
VDC
1,9/3,9
10%
225/900
Insulation resistance (at 1000V DC)
min
10
Operate time
max
ms
2,6
Release time including bounces
max
ms
3,6
Breakdown voltage coil-contact
min
kVDC
15
Coil resistance
2/4
9/18 8,9/17,9 250/1000
275/1100
3. RELAY PARAMETERS 11
Environment category acc. to IEC 68-2-1÷3
40/85/21
4. DIMENSIONS AND TERMINAL ARRANGEMENTS all dimensions in mm 2 2 3
1
100 min
4 1
+12V/24V
63 max
24,5 max
2x 1
*Coil polarity must be observed. See drawing for the positive pin. Relays are susceptible to magnetic interaction due to bias internal magnet. No 6/09.2010
17.8
4,5
4.0 max
19 max
~5