Preview only show first 10 pages with watermark. For full document please download

Hv Reed Relays K-551h, K-552h K-553h, K-554h, K

   EMBED


Share

Transcript

HV reed relays K-551H, K-552H K-553H, K-554H, K-555H form A contact (normally open) PIT-RADWAR S.A. WROCLAW DIVISION for PCBs 50-425 Wrocław, ul. Krakowska 64, Poland tel. (+48) 71/342-65-54, fax (+48) 71/342-58-59 e-mail: [email protected] www.dolam.pl This product is in accordance with RoHs TYPE PARAMETERS Unit K-551H K-552H K-553H K-554H K-555H 1.CONTACT PARAMETERS Switching power max W, VA Breakdown voltage Switching voltage (DC or AC PEAK) min max kV D C kV Switching current max A Initial contact resistance max m Life expectancy Load 1 5 kVD C, Load 2 7,5 kVD C , Load 3 10 kV DC , 50 7 5 10 10 7,5 14 10 17 18 12 2 1 150 operations 0,5x10 6 1 mA 1 mA 1 mA 0,5x106 0,5x106 0,5x106 2. COIL PARAMETERS Nominal voltage VD C 5/6/12/24 Pull-in voltage max VD C 4/4,5/9/18 Drop-out voltage min VD C 0,5/0,6/1/2 Coil resistance ±10%  45/45/180/650 Insulation resistance (at 1000VD C ) min  Operate time including bounces max ms 3,6 Release time max ms 0,5 Breakdown voltage coil-contact min kV D C 3. RELAY PARAMETERS 101 0 (at 70°C) 101 2 (at 20°C) 15 30 Environment category acc. to IEC 68-2-1÷3 40/85/21 4. DIMENSIONS AND TERMINAL ARRANGEMENTS all dimensions in mm 63.5 4x 1.6 12.7 4 1 3 4 2 2 100 min ~5 17.4 max No 6/02.2017 58 19.5 max  4.0 max 1 min 70.8 max 2x  1 12.7 4.5 1 3 0,5x106 HV reed relays K-555S form A contact (normally open) PIT-RADWAR S.A. for PCBs WROCLAW DIVISION 50-425 Wrocław, ul. Krakowska 64, Poland tel. (+48) 71/342-65-54, fax (+48) 71/342-58-59 e-mail: [email protected] www.dolam.pl This product is in accordance with RoHs TYPE PARAMETERS Unit K-556S 1.CONTACT PARAMETERS Switching power max W, VA 10 Breakdown voltage min kV D C 19 Switching voltage (DC or AC PEAK) max kV 12 Switching current max A 1 Initial contact resistance max m 150 Life expectancy Load 3 operations 10 kV DC , 6 1 mA 0,5x10 2. COIL PARAMETERS Nominal voltage VD C 24 Pull-in voltage max VD C 18 Drop-out voltage min VD C 2 Coil resistance ±10%  400 Ins ulation resistance (at 1000VD C ) min  Operate time including bounces max ms 3,6 Release time max ms 0,5 Breakdown voltage coil-contact min kV D C 30 3. RELAY PARAMETERS 101 0 (at 70°C) Environment category acc. to IEC 68-2-1÷3 101 2 (at 20°C) 40/85/21 4. DIMENSIONS AND TERMINAL ARRANGEMENTS all dimensions in mm 63.5 4x 1.6 12.7 4 1 3 4 2 2 100 min ~5 17.4 max No 1/03.2011 58 19.5 max  4.0 max 1 min 70.8 max 2x  1 12.7 4.5 1 3 HV reed relays K-561H, K-562H form A contact (normally open) for PCBs PIT-RADWAR S.A. WROCLAW DIVISION 50-425 Wrocław, ul. Krakowska 64, Poland tel. (+48) 71/342-65-54, fax (+48) 71/342-58-59 e-mail: [email protected] www.dolam.pl This product is in accordance with RoHs TYPE PARAMETERS Unit K-561H K-562H 1.CONTACT PARAMETERS Switching power max W, VA 50 Breakdown voltage min kVDC 7 10 Switching voltage (DC or AC PEAK) max kV 5 7,5 Switching current max A 2 Initial contact resistance max m 150 Life expectancy operations 6 Load 1 5 kVDC, 1 mA 0,5x10 Load 2 7,5 kVDC, 1 mA 0,5x10 6 2. COIL PARAMETERS Nominal voltage VDC 5 6 12 24 5 6 12 24 Pull-in voltage max VDC 4 4,5 9 18 4 4,5 9 18 Drop-out voltage min VDC 0,5 0,6 1 2 0,5 0,6 1 2 Coil resistance ±10%  45 45 180 650 45 45 180 650 Insulation resistance (at 1000VDC) min  Operate time including bounces max ms 3,6 Release time max ms 0,5 Breakdown voltage coil-contact min kVDC 15 3. RELAY PARAMETERS 10 12 10 (at 70°C) Environment category acc. to IEC 68-2-1÷3 10 (at 20°C) 40/85/21 4. DIMENSIONS AND TERMINAL ARRANGEMENTS all dimensions in mm 1 3 4 12.7 63.5 1 3 2 4 2 53.3 70.8 max No 7/01.2007 4x  1 58 12.7 4.5 1min 19.5 max 17.4 max HV red relays R-561,R-562 form A contact (normally open) for PCBs PIT-RADWAR S.A. WROCLAW DIVISION 50-425 Wrocław, ul. Krakowska 64, Poland tel. (+48) 71/342-65-54, fax (+48) 71/342-58-59 e-mail: [email protected] www.dolam.pl PARAMETERS This product is in accordance with RoHs TYPE Unit R-561 R-562 1. CONTACT PARAMETERS Switching power max W,VA 50 Breakdown voltage min kVDC 7 10 Switching voltage (DC or AC PEAK) max kV 5 7,5 Switching current max A 2 Initial contact resistance max m 150 operations Life expectancy 6 0,5x10 Load 1 5 kVDC, 1 mA Load 2 7,5 kVDC, 1 mA 6 0,5x10 2. COIL PARAMETERS Nominal voltage VDC 5 6 12 24 5 6 12 24 Pull-in voltage max VDC 4 4,5 9 18 4 4,5 9 18 Drop-out voltage min VDC 0,5 0,6 1 2 0,5 0,6 1 2 Coil resistance ±10%  45 45 180 650 45 45 180 650 Insulation resistance (at 1000VDC) min  o 10 (at 20 C) Operate time including bounces max ms 3,6 Release time max ms 0,5 Breakdown voltage coil-contact min kVDC 15 3. RELAY PARAMETERS 10 12 10 (at 70 C) Environment category acc. to IEC 68-2-1÷3 o 40/85/21 4. DIMENSIONS AND TERMINAL ARRANGEMENTS 53.3 all dimensions in mm 1 3 1 3 4 4 2 2 17 max 17,8 max 65 max 12,7 No 5/04.2009 4.5 4x1 HV reed relays K-561B, K-562B form B contact (normally closed) for PCBs PIT-RADWAR S.A. WROCLAW DIVISION 50-425 Wrocław, ul. Krakowska 64, Poland tel. (+48) 71/342-65-54, fax (+48) 71/342-58-59 e-mail: [email protected] www.dolam.pl This product is in accordance with RoHs TYPE PARAMETERS Unit K-561B K-562B 1.CONTACT PARAMETERS Switching power max W, VA 50 Breakdown voltage min kVDC 7 10 Switching voltage (DC or AC PEAK) max kV 5 7,5 Switching current max A 2 Initial contact resistance max m 150 Life expectancy operations Load 1 5 kVDC, 1 mA Load 2 7,5 kVDC, 1 mA 6 0,5x10 6 0,5x10 2. COIL PARAMETERS Min Nom Max 12/24 16/30 Coil voltage* VDC Pull-in voltage VDC 2/4 9/18 Drop-out voltage VDC 1,9/3,9 8,9/17,9 ±10%  225/900 Insulation resistance (at 1000VDC) min  10 Operate time max ms 2,6 Release time including bounces max ms 3,6 Breakdown voltage coil-contact min kVDC Coil resistance 250/1000 3. RELAY PARAMETERS 11 15 Environment category acc. to IEC 68-2-1÷3 40/85/21 4. DIMENSIONS AND TERMINAL ARRANGEMENTS all dimensions in mm 53.3 2 2 2 3 3 4 1 4 1 +12V/24V 63 max 19 max 24,5 max 17.8 *Coil polarity must be observed. See drawing for the positive pin. Relays are susceptible to magnetic interaction due to bias internal magnet. No 5/08.2006 4.5 4x  1 275/1100 HV reed relays K-551B, K-552B form B contact (normally closed) PIT-RADWAR S.A. for PCBs WROCLAW DIVISION 50-425 Wrocław, ul. Krakowska 64, Poland tel. (+48) 71/342-65-54, fax (+48) 71/342-58-59 e-mail: [email protected] www.dolam.pl This product is in accordance with RoHs TYPE PARAMETERS Unit K-551B K-552B 1.CONTACT PARAMETERS Switching power max W, VA 50 Breakdown voltage min kVDC 7 10 Switching voltage (DC or AC PEAK) max kV 5 7,5 Switching current max A 2 Initial contact resistance max m 150 Life expectancy operations Load 1 Load 2 5 kVD C, 7,5 kV DC, 6 1 mA 1 mA 0,5x10 0,5x10 6 2. COIL PARAMETERS Min Nom Max 12/24 16/30 Coil voltage* VDC Pull-in voltage VDC Drop-out voltage VDC 1,9/3,9 10%  225/900 Insulation resistance (at 1000V DC) min  10 Operate time max ms 2,6 Release time including bounces max ms 3,6 Breakdown voltage coil-contact min kVDC 15 Coil resistance 2/4 9/18 8,9/17,9 250/1000 275/1100 3. RELAY PARAMETERS 11 Environment category acc. to IEC 68-2-1÷3 40/85/21 4. DIMENSIONS AND TERMINAL ARRANGEMENTS all dimensions in mm 2 2 3 1 100 min 4 1 +12V/24V 63 max 24,5 max 2x  1 *Coil polarity must be observed. See drawing for the positive pin. Relays are susceptible to magnetic interaction due to bias internal magnet. No 6/09.2010 17.8 4,5  4.0 max 19 max ~5