Preview only show first 10 pages with watermark. For full document please download

H.v. Test (pty) Ltd

   EMBED


Share

Transcript

H.V. TEST (PTY) LTD 3 Gaiety Ave, Robindale, Randburg, South Africa, 2010 Tel: +27(11) 782 1010 Fax: +27(11) 782 2770 P.O. Box 651287, Benmore, 2010 Email: [email protected] Website: www.hvtest.co.za Resistor Type Transducer Input Channel One optional resistor type input channel is also available with the CT-7000. This input channel allows the CT-7000 to interface directly with resistive type transducers (optional). The transducer resistance ranges from 200 ohm to 10K Ohm. Timing Record Storage Capabilities The CT-7000 uses Flash Electrically Erasable PROMs (EEPROMs) to store timingrecord data. Unlike other storage media, EEPROMs are immune to shock, temperature, and humidity. Stored timing records can be recalled by users to re-analyze test data, to print copies, or to transfer data to an IBM-compatible PC for record keeping. Up to 100 timing records can be stored in EEPROMs. Breaker Test Plan CT-7000 The Model CT-7000 Series 2 is a third generation, stand-alone, microcomputerdriven EHV Circuit-Breaker Analyzer. It is inexpensive and easy to use. The CT7000 is available in models with 3 dry contacts (CT7000-3), 6 dry contacts (CT7000-6), or 12 dry-contact inputs (CT-7000-12). The CT-7000 fully analyzes circuit-breaker performance: contact time, stroke, velocity, over-travel, and contact wipe. Contact-motion analysis includes: Open, Close, Open-Close, Close-Open, and Open-Close-Open. The CT-7000 timing window is selectable: 1-second, 10second, or 20-second periods. The 10-second and 20-second timing windows allow timing of long duration events (Circuit-Switcher contacts). Contact Timing Inputs Breaker contact timing uses dry-contact input channels. Each contact-input channel can detect main contact and insertion-resistor contact times (displays milliseconds and cycles). Voltage Monitoring Inputs One analog voltage input channel is dedicated to monitoring circuit-breaker dc power supply or coil voltages 0 to 300 volts, dc or peak ac. One digital voltage input channel allows users to monitor voltage on/off status of an A/B switch. Trip/Close Current Monitoring A built-in Hall-effect current sensor records Trip/Close current level and duration. The breaker’s operate-coil current waveform duration (effectively, a performance "fingerprint" or "current profile") can be used as a diagnostic tool for analysis of a breaker’s performance. Breaker Stroke and Velocity Three travel transducer digital channels let the CT-7000 measure stroke, over-travel, and bounce-back. Unlike other types of transducers, the digital transducer requires neither calibration nor setup. A breaker contact-velocity calculation is based on a contact’s travel distance over a period of time, which is defined by the breaker manufacturer’s specifications. A special feature lets users "slow-close" a breaker and produce a test result report. Up to 99 circuit-breaker test plans can be stored in the CT-7000. Test plans comprise all circuit-breaker performance specifications (stroke, velocity, contact time). By recalling a test plan, the user can immediately test a breaker and view a pass/fail report (made by comparing actual performance with the specifications listed in the stored test plan). A user does not need to look-up the breaker specifications to compare with the test results to determine if the breaker passed the performance tests. Test plans can be downloaded to the CT-7000 via a USB or RS-232C port. Breaker Initiate Features A built-in solid-state initiate device lets users operate the breaker from the CT7000. The operational modes include: Open, Close, Open-Close, Close-Open, and Open-Close-Open. Multiple operations (e.g., Open-Close, Open-CloseOpen) can be initiated by using programmable delay time or by sensing the breaker’s contact condition. Diagnostic Capabilities The CT-7000 can perform diagnostics on its internal electronics. Self testing of transducer and contact-test cables lets users check out the Timer whenever verification is required. Computer Interface The CT-7000 can be used in the stand-alone mode or computer controlled mode. USB and RS-232C Ports allow an IBM-PC compatible computer to control the CT-7000. From the PC, circuit breakers can be timed and users can retrieve timing shots saved in the CT-7000 flash EEPROM. A Windows® XP-based Breaker-Analysis software lets users time circuit breakers, retrieve test-shot data stored in the computer’s hard-drive, re-analyze the stored data, and generate reports in the office. Test reports can be exported to Excel, allowing the user to generate customized test-result reports. Users may also create a circuitbreaker database library. Additionally, users can create circuit-breaker test plans to be downloaded to the CT-7000. User Interface An alpha-numeric keypad lets users enter breaker ID and control functions. A 4line by 20-character LCD readout displays user messages. The LCD is back lighted so messages can be viewed in low light levels. A display contrast control is located on the front panel. Built-in Thermal Printer A built-in thermal printer prints the breaker contact analysis results in both tabular and graphic formats on 4.5-inch-wide thermal paper. Digital Circuit Breaker Analyzer H.V. TEST (PTY) LTD 3 Gaiety Ave, Robindale, Randburg, South Africa, 2010 Tel: +27(11) 782 1010 Fax: +27(11) 782 2770 P.O. Box 651287, Benmore, 2010 Email: [email protected] Website: www.hvtest.co.za alyze Contact Timing Channel Voltage Input Channels RS-232C Port Trigger Input Connector Linear Transducer Resistor Type Transducer Connector USB Port Digital Transducer Connector Thermal Printer Breaker Initiate Output 4x20 Backlit LCD Display 16-Key Membrane Keyboard Breaker Initiate Arm Switch H.V. TEST (PTY) LTD 3 Gaiety Ave, Robindale, Randburg, South Africa, 2010 Tel: +27(11) 782 1010 Fax: +27(11) 782 2770 P.O. Box 651287, Benmore, 2010 Email: [email protected] Website: www.hvtest.co.za Graphic and Tabulated Printouts CT-7000 S2 Digital Circuit Breaker Analyzer ▼ EEPROM Stored Test Parameters ▼ Built-in Thermal Printer Output ▼ PC Printer Output H.V. TEST (PTY) LTD 3 Gaiety Ave, Robindale, Randburg, South Africa, 2010 Tel: +27(11) 782 1010 Fax: +27(11) 782 2770 P.O. Box 651287, Benmore, 2010 Email: [email protected] Website: www.hvtest.co.za FEATURES • Full Breaker Tabulated & Graphic Data Printout • Built-in Thermal Printer • Initiate Breaker Operation • Digital Travel Transducer; No Setup or Calibration Required • Detect Main Contact and Insertion Resistor Contact on the Same Input Channel • On-Board Flash EEPROM Shot Storage • Diagnostic Capabilities • On-Board Flash EEPROM Test Plan Storage • Computer Interface SPECIFICATIONS TYPE PHYSICAL SPECIFICATIONS INPUT POWER DRY-CONTACT INPUTS TIMING WINDOWS TIMING RESOLUTION TIMING ACCURACY DRY CONTACT CHANNEL PROTECTION DRY CONTACT DETECTION RANGE RESISTOR DETECTION RANGE TRIGGER INPUT VOLTAGE VOLTAGE SENSING INPUT RANGE BREAKER OPERATION BREAKER INITIATE CAPACITY INITIATE CURRENT READING RANGE DIGITAL TRAVEL TRANSDUCER INPUT RESISTOR TYPE TRANSDUCER INPUT CONTACT TRAVEL POINT DIFFERENCE DISPLAY PRINTOUT TEST RECORD STORAGE COMPUTE INTERFACE PC SOFTWARE SAFETY ENVIRONMENT OPTIONS WARRANTY Special purpose test equipment, portable circuit breaker analyzer 16” W by 11” H by 14” D (40.6 cm x 29.9 cm x 35.6 cm); Weight, less than 25 lbs (11.3 kg) 90-130 Vac or 200-240 Vac (selectable), 50/60Hz 3, 6 or 12 dry-input channels. Each channel detects Main and Insertion-Resistor Contacts Selectable: 1-second, 10-seconds, 20-seconds ±50 microseconds at 1-second duration, ±500 microseconds at 10-second duration, ±1.0 milliseconds at 20-second duration 0.05% of reading, ±0.05 ms at 1-second duration Fuses protect all isolated power supplies. All contact inputs are grounded until test. TVS and Zenerdiode protected. Closed: <20 ohm, Open:> 5,000 ohm 50 to 5,000 Ohm Open/Close: 30-300V dc or peak ac V1: analog input; 0-255V dc or peak ac, Sensitivity ±1V; V2: voltage detector (present/absent) input; 30-300V cd or peak ac Initiate Open, Close, Open-Close, Close-Open, Open-Close-Open 30A/250V ac/dc max One, Non-contact, Hall-Effect sensor, 0-20A, dc to 5Khz 3 digital travel transducer channel; Linear range, 0.0-60.0 in (±0.01 in); Rotary range 0-360° (±0.36°) 200 Ohms to 10K Ohms (optional) Measures “Slow-Close” contact-point distances (hard copy) 4 lines by 20 character back-lit LCD, sunlight viewable Both graphic contact and travel waveforms & tabulated results are printed on 4.5-inch thermal printer Store up to 100 timing records and 99 test plans USB and RS-232C port Furnished Circuit breaker analysis software running under Windows XP; features graphic display, numerical reports, and data base utility for use at shop or office. Designed to meet UL 6101A-1 Certification and CAN/CSA C22.2 No 1010.1-92 Operating: -10°C to 50°C (+15°F to +122°F); Storage: -30°C to70°C (-22°F to +158°F) Hard case for shipping; available for both Travel Transducers and CT-7000 One-year warranty on parts and labor Note: The above specifications are valid at nominal voltage and ambient temperature of +25°C (+77°F). Specifications are subject to change without notice. H.V. TEST (PTY) LTD 3 Gaiety Ave, Robindale, Randburg, South Africa, 2010 Tel: +27(11) 782 1010 Fax: +27(11) 782 2770 P.O. Box 651287, Benmore, 2010 Email: [email protected] Website: www.hvtest.co.za