HEX390 HEX390 Domestic Ventilation System with Heat Exchanger Balanced Pressure Ventilation
Supply Air Return Air
Exhaust Air Outside Air
HEX390 Heat Exchange unit
HEX390 Warranty 5 years manufacturing warranty from date of first retail purchase. This HEX product, when delivered to you in new condition from a HEX authorized dealer and used in normal conditions, will be free from any defects in manufacturing, materials and workmanship for the periods set out above (“Warranty Period”): Any faulty goods will be repaired or replaced via the HEX dealer. This warranty is for the manufactured product, it does not include installation or removal. HEX390 Hybrid Controller user manual 2017
v3.1.762
by
1
Hybrid Controller - User Operating Instructions Hybrid Manual Digital Display Controller with Programmable Timer & Thermometer - Manually change the fan speed of the unit to high, medium and low. - Or set a schedule to automatically change the fan speed during the day, to meet the changes in demand of household activities. 1
2
3
14
4
13
5
12
6
11
7
Capacitive buttons:
On/Off Menu
Up
10
Down
Return
9
8
1. Time Clock Setting mode 2. Filter Warning 3. Room Temperature 4. Real Time Clock Display 5. Key Pad Lock 6. Next Step In Schedule Setting 7. Exit Schedule Setting 8. Bypass Setting 9. Fan Speed 10. Air Quality Bar (not available) 11. System Off Indicator 12. Schedule Setting and Indicator 13. Installer Test 14. Installer Setup menu
Power on or off Press On/Off button to power on or off the unit. The indoor temperature will be displayed whether unit is on or off. icon will display when off.
Clock setting screen, use arrows to set clock, enter/return to exit
Fan setting From the home screen, press the up or down arrows to increase or decrease the fan speed (can only be changed if fan scheduler is disabled). Bypass setting (optional extra) If core bypass is installed, bypass can be activated or deactivated by pressing the Return button from the home screen. This function can be used during summer months when cooling of indoor environment is required. Keypad lock See p16 for Keypad lock functions. Schedular See over page to scheduler setting
HEX390 Hybrid Controller user manual 2017
Home screen
Flashing
Clock setting After powering on (or after pressing menu button), the system enters the clock setting mode, and display will show a flashing time. Press up or down arrows to set clock, press Return button to confirm and exit.
2
Hybrid - manual controller with digital display
by
Timer schedule setting - Scheduler is used to change the fan speed or turn unit on or off during specified periods of the day to suit household activities eg cooking etc. Scheduler on
To turn Scheduler on or off: Press the Menu button once to set time clock, press again to enter Schedule Setting mode. Up or down buttons can turn schedule function on or off, selected option will be flashing. Press Return button to confirm.
Scheduler off
Time slot
Start time
To programme scheduler function: With Scheduler on, follow and repeat the steps below to programme up to 8 time slots: 1. Select time slot: press the up or down arrow to select the time slot (1-8), press Return to confirm which slot & move to next step. 2. Select time: Press up or down arrow to select time for this slot, press Return to confirm & move to next step.
Selected fan speed for this time slot
3. Select fan speed: Press up or down arrow to select fan speed for this slot, press Return to confirm & move to next step.
Next time slot
4. Select next time slot or exit: Press up or down arrow to select next time slot (horizontal arrow icon) or Exit door icon to exit scheduler. Press Return to confirm selection.
Save and exit Time slot is disabled
Press Menu button to disable/enable the shedular function. The scheduler function is based on a 24hr time slot and repeats daily. Example schedule below: 24 hr cycle Time slot:
1
2
3
4
5
6
7
8
Start time:
3.00
7.30
9.30
16.00
18:00
19.30
21.00
23.59
Fan Speed:
Low
Medium
High
Medium
Low
Medium
Low
Off
Example of schedule with high air exchange during the day. Generally larger houses need higher fan speeds to provide optimal air changes.
Troubleshooting Tips If...
Then...
Missing one or more fan speed
Check the wiring of terminals FH, FM and FL is correct. Check system type and fan control type in ths Installer Set Up table is correct (index 1 & index 5)
Bypass function doesn't work
Check the HEX system has a bypass function. Check wiring of terminal BOP is correct. Check Bypass is enabled in index 2)
Filter warning icon is flashing
Inspect the filters and clean or replace if necessary. (We recommend every 5-8 months). The counter can be reset by pressing and holding both the menu and enter/return buttons simultaneously
A button doesn't work
Check system configuration for keypad lock (p16 index 10).
Air Quality bar flashing
Check index 1 - should be set to 0 - without sensor.
HEX390 Hybrid Controller user manual 2017
by
3
Maintenance Filters The unit is supplied with two G3 pre filters. If required, an F7 filter (FBP200+FBPF7) can be installed in the supply side for extra filtration. Alternatively a standard EU2 filter can be used (FBP200+FBPF2). Cleaning the filters The internal filters are designed as secondary filters (there should be extended surface filters cleaning the air before reaching the unit). However, when unit filters are heavily soiled, wash or replace the filter material with "HexFilter" (234x380mm) or "HexFilter 222" (222x380mm) for 2015 and earlier models. To wash: use vacuum cleaner to remove excess dust, then wash in warm detergent treated water, keep filters flat or leave in frame to wash.
Return Air filter Supply Air
Return Air
Outside Air
Exhaust Air
HEX body
Fresh Air filter
Manual Controller - User Operating Instructions Manual Controller This unit has High / Medium / Low speeds which the homeowner can use to regulate the fresh air amount to suit the load. The 3 speed switch has four settings: Typically: 3 - High - where a number of people are living in the house and/or outside temperatures are moderate 2 - Medium - less people in the house and/or colder outside temperatures 1 - Low - mainly to keep air fresh in the home during extremely cold conditions. 0 - Off 3 speed switch