Preview only show first 10 pages with watermark. For full document please download

Hybrid Ups - Sanyo Denki Europe S.a.

   EMBED


Share

Transcript

HYBRID UPS E11A AC 230 V Model Hybrid UPS Saves Energy and Achieves High Reliability SANUPS E11A HYBRID UPS Input Output AC 230 V AC 230 V single-phase 2-wire single-phase 2-wire 19 NETWORK MONITORING inch rack Mountable EIA Output capacity 1 kVA (0.7 kW) 2 kVA (1.4 kW) 3 kVA (2.1 kW) The advancement of technology has increased the demand for quality power. In a perfect world, commercial power would always be stable and normal, however, we live in a world in which electricity from local utilities typically experiences anomalies such as spikes, surges, electrical noise, load fluctuations, and outages. To protect your investments in technology equipment from these problems, informed users rely on SANYO DENKI SANUPS E11A products to resolve these power issues and provide continuous, clean power to connected equipment. Not only does the SANYO DENKI SANUPS E11A create continuous and clean power, it is an intelligent device in which power is consumed only when power conditions are unfavorable, making the unit highly efficient. The SANYO DENKI SANUPS E11A Hybrid UPS provides highly efficient power protection to everything from heavy machinery and manufacturing devices to complex server systems and sensitive communication equipment (Voice and Data). With over 40 years of UPS experience, SANYO DENKI ensures the superior quality of the SANUPS E11A Hybrid UPS and provides the product equipped with extra long life batteries. The SANUPS E11A Hybrid UPS - a product truly in a class of its own. 1 Hybrid UPS-Energy conservation 2 Self battery check feature 3 UPS Management options Mounted in a 19-inch rack ● Includes metal brackets for 19 inch rack installation. ● Rack support rail is optional. 2 Vertical Installation Includes vertical stand for upright support. ● 1 Hybrid UPS-Energy conservation ■ Conversion efficiency has reached 95%. This represents a 4% improvement over previous products (comparison performed at 1kVA / Economy mode.). Conversion Efficiency 95% Commercial Power Load Device SANUPS E11A ■ The Hybrid type SANUPS E11A automatically selects the most efficient mode of operation for any given power condition. *The mode can be fixed manually. However, the ACTIVE FILTER mode cannot be fixed. Under good power condition ECONOMY mode Hybrid Method SANUPS E11A ACTIVE FILTER mode Under unfavorable power factor Harmonic noise Suppresses high frequencies generated by load and improves power factor. DOUBLE CONVERSION mode Under unfavorable power condition Momentary blackout Voltage fluctuation Frequency fluctuation Harmonic noise 3 2 Self battery check feature ■ The SANUPS E11A automatically performs regular battery tests for operation during a power outage, and maintains peak battery conditions for reliable operation during an actual power outage. *The frequency of the battery test is open to configuration. (Test frequency choices are 1, 3 and 6 months; the factory setting is 6 months.) *Sudden stoppage does not occur during battery operation test, no matter what the power supply mode. *A LAN interface card (optional) is necessary to transmit the battery test results to the user’s PC. Begin Testing Battery Test Normal Operation Commercial Power Rectifier Load Device Inverter Periodic Check Commercial Power Rectifier Battery Inverter Battery Return to Normal Operations * If a decline in the battery function is detected during test mode, normal operation will resume. 3 UPS Management options ■ To increase user control over equipment protection, our stand-alone windows compatible UPS Management Software “SANUPS SOFTWARE STANDALONE” is provided as a standard accessory. Use it to improve the utility of the UPS, through useful functions such as monitoring UPS performance over a network connection and configuring shutdown settings. PC SANUPS SOFTWARE STANDALONE RS-232C SANUPS E11A Compatible operating systems Windows NT4.0 Windows 2000 Windows XP Windows Server 2003 Windows Server 2008 Windows Vista Windows 7 Windows 8 Windows Server 2012 Network support options ■ LAN interface card ■ SANUPS SOFTWARE Installing a LAN interface card in the option The SANUPS SOFTWARE UPS Power card slot at the back of the unit allows for Management Software increases the continuous monitoring and reporting of power reliability and manageability of the entire conditions, and quick response during power system, including the network and the failures. Power problems can also be reported server. It provides UPS information to the to the System Manager via e-mail. system manager, and a variety of settings for handling power-related problems. Model : PRLANIF003-US PRLANIF005-US ■ Dry contact signal interface card When a Dry contact signal interface card is installed in the option card slot at the back of the unit, the external transmission signal can be output as a no-voltage contact signal to indicate the status of the UPS. Model: PRCONIF001-US(Terminal block output) PRCONIF003-US(D-Sub connector output) 4 PMS40H00E (without cable) Windows Multiple OS* PMS41H00E (without cable) *For Windows, Unix and Linux Load Device Front Battery Power Low LED Alarm LED Inverter Switch Battery Test Switch Clear Switch Input LED Output LED Supply Mode LED Load Level Display Back (1kVA) Option Card Slot EPO, Systematic Control Contact Point Output Plug / Connection (IEC60320-C13) PC Interface (RS-232C) Option Card Interface Input Cable (1.8m) Input Plug / Connection External Battery Connection Port Remote Interface Power Switch (ON/OFF) Interface & INPUT/OUTPUT Connection Chart Output (kVA) CE Model No. PC (RS-232C) Remote EPO ※ Systematic control contact point INPUT Plug/Connection OUTPUT Plug/Connection 1 E11A102BDE12 IEC60320-C14 to CEE7 line cord option included. IEC60320-C13×4 2 E11A202BDE12 IEC60320-C20 to CEE7 line cord option included. IEC60320-C19×3 3 E11A302BDE12 ※ EPO = Emergency Power Off 5 Specifications E11A Item Remarks Economy mode* Active filter mode* Output power 1 kVA (0.7kW) / 2kVA (1.4 kW) / 3 kVA (2.1 kW) System Topology Hybrid Cooling Forced Air IEC Classification VFD-SS-311 AC Input Single-phase / 2 wire AC Output Number of phases / wires VFI-SS-111 Nominal voltage 230V Voltage range ±8% Max. Frequency 50 Hz Frequency range ± 1%, 3%, 5% Max. Power factor 0.7 Number of phases / wires Single-phase / 2 wire User selectable +5% Max. -20% to +15% 0.85 Min. 0.95 Min. Auto selected mode 5% Max. ±8% Max. < 1% Input voltage distortion Power factor 0.7 (lag)  Fluctuation tolerance: 0.7(lag) to 1.0 Nominal voltage 230V User selectable Voltage regulation -10% to +8% (Auto selected mode -7% to 5%) Nennfrequenz 50 Hz Frequency range Voltage distortion Transient voltage regulation -7% to 5% ±2% Max. In terms of domain of load and input Same as input frequency On Normal Operation ±1, 3, 5% Max. ±1% Max. On Battery Operation ― ±0.5% Max. User selectable ― 3% Max. During rated operations Non-linear load ― 7% Max. During rated operations / 100% rectifier load Input Voltage ― step ±5% Max. Power failure: feedback or supply fluctuation Linear load 100% step load ― Overcurrent capacity Overcurrent protection Battery Double Conversion mode ±5% Max. 0% : at the time of 100% sudden fluctuation Greater than 200% (30 second interval) 105% (200ms) Rated load power factor / at rated input Greater than 800% (2 cycle) ― Breaker Protection Bypass Non-Hit Change (Auto Return) Auto-return can be disabled Type Maintenance Free Sealed Lead-Acid Battery (small) Backup time 5minutes Ambient Temp. of 25°C , under rated load 1 kVA : 40 dB MAX. 2 kVA, 3 kVA : 45 dB MAX. Double conversion mode 1 kVA : 125W, 2 kVA : 270W, 3 kVA : 460W At 1m (40in) from the front of unit , At Economy mode Acoustic noise Nominal heat dissipation Environment Operating temperature Relative humidity Standard of safety EMC standard 0 to 40°C 20 to 90% Non-condensing CE: IEC62040-1:2008 Emission EN62040-2 C2:2006, EN55022:2006 Class-A (FCC Part15 Sub partB Class-A, CISPR 22 Class A) Immunitiy EN62040-2:2006, EN55024:1998/A1:2001/A2:2003 *A momentary power interruption lasting less than 5 ms occurs when switching from Economy Mode or Active Filter Mode to battery power. The unit can also be fixed to the Double Conversion Mode for applications that require zero transfer time from utility power to battery power. Dimensions Dimensions (mm) W Width (W) H D Paint color: Black (Munsell N1.5) 6 1 kVA 2 kVA 3 kVA Depth (D) 408 440 565 750 Mass (kg) Height (H) 17 86 29 39 Run-time chart Model No. E11A102BDE12 E11A202BDE12 E11A302BDE12 Max. Output (VA) 1000 2000 3000 Max. Output (W) 700 1400 2100 VA W Run-time (Min) 100 70 87 150 240 200 140 48 87 150 300 210 30 61 87 400 280 20 48 71 500 350 15 37 54 600 420 12 30 48 700 490 9 25 40 800 560 7 20 34 900 630 6 18 31 1000 700 5 15 28 1200 840 12 20 1400 980 9 17 1500 1050 8 16 1600 1120 7 14 1800 1260 6 12 2000 1400 5 10 2200 1540 9 2400 1680 8 2600 1820 7 2800 1960 6 3000 2100 5 *The above run-time value assumes a load power factor = 0.7. *Figures should be used for reference only. Actual backup times depend on charging conditions, ambient temperature, years in use, etc. Option Item Model No. Rack support rail RM030-US Used for mounting the UPS onto a 19 inch rack. Supports depth of 555mm to 913mm. ■ External battery Dimensions (mm) Width(W) Model No. BCE11A102A01US for 1kVA BCE11A202A01US for 2kVA BCE11A302A01US for 3kVA Depth(D) Height(H) 408 440 565 86 750 Mass(kg) Run-time (Min.) 20 40 60 20 1 unit 2 unit 3 unit 34 1 unit 2 unit 3 unit 52 1 unit 2 unit 3 unit ■ Rack support rail (RM030-US) External demensions External demensions W Effective dimensions (when fully retracted) B A B C 86.6mm 555mm 913mm D A Paint color: Black (Munsell N1.5) Effective dimensions (when fully extended) A H C ■ Battery module can be replaced by removing the front panel, while the power is turned on. 7 Eco Products Sanyo Denki’s ECO PRODUCTS are designed with the concept of lessening impact on the environment in the process from product development to waste.The product units and packaging materials are designed for reduced environmental impact.We have established our own assessment criteria on the environmental impacts applicable to all processes,ranging from design to manufacture.Those products that satisfy the criteria are accredited as ECO PRODUCTS. Notes when investigating use of this product in your applications Before starting installation, assembling and use, read the “Operation Manual” carefully and use the product correctly in your applications. When you are going to use this product in the following application, the special considerations are required for operation, running, maintenance and control. Be sure to consult with our company as a part of your investigations. (a) Medical equipment and other equipment that are related directly to human life. (b) Train or elevator that can give injury to human body. (c) Socially and publicly important computer systems. (d) And other equipment that are related to safety of human life and that can affect severe effects on maintenance of public functions. For the applications that undergo vibration such as vehicles, ships and transportation facilities, please consult with our company. Never modify this product or give additional processing to this product. For the installation andmaintenance work, please consult with our company or with specialized company. http://www.sanyodenki.com 3-33-1, Minami-Otsuka, Toshima-ku, Tokyo, 170-8451, Japan P.A. Paris Nord Ⅱ, 48 Allée des Erables-VILLEPINTE, BP.57286, F-95958 ROISSY CDG Cedex, France Phone: +81 3 5927 1020 http://www.sanyodenki.eu Phone: +33 1 48 63 26 61 The names of companies and/or their products specified in this catalog are the trade names, and/or trademarks and/or registered trademarks of such respective companies. *Specifications are subject to change without notice. CATALOG No.P0884B005’14.4