Overview
KEY BENEFITS
The HyperGrid all-flash HyperConverged Appliance (HCA) combines compute, storage area network, and storage into a single 2U system, reducing the data center footprint by 75%. Compared to other HCI solutions, as well as converged and traditional infrastructure, HyperGrid HCI: ™
●●
●●
●●
Performs 6-10 times faster than traditional infrastructure, due to all-flash storage and inline erasure coding Costs 50-66% less than the leading HCI vendor, with independent compute and storage scaling (no dedicated CPU/ memory allocation required by other HCI solutions) Supports a higher density of virtual machines (VM) for the highest price/ performance ratio in the industry
Architecture
HyperGrid is the only HCI with a parallel all-flash architecture with in-kernel processing for easy deployment and cost-effective scaling. Instead of replicating the full infrastructure stack three times like other HCI platforms, HyperGrid uses erasure coding that offers the same fault tolerance and usable capacity but uses 50% less storage and system load. HyperGrid HCI can be tailored per workload/environment as follows:
A four-node HyperGrid HCA can have: ●●
All-Flash HyperConverged Nodes (FCNs)
●●
All-Flash Storage-only Nodes (FSNs)
●●
A mixture of FCNs and FSNs
●●
Up to six drives per node
A two-node HyperGrid HCA for high performance graphics processing can have: ●●
All-Flash Graphics Nodes (FGNs)
●●
A mixture of FGNs, FCNs, and FSNs
●●
Up to 12 drives per node
●●
●●
●● ●●
●●
●●
Use Cases
HyperGrid HCI simplifies the data center and moves business to the Digital Enterprise. It is purpose-built for the Microsoft ecosystem, allowing even greater savings with support for Microsoft data services and Azure integration. It is the fastest HCI with the greatest scalability for the following use cases across all industries: ●●
Virtual Desktop Infrastructure (VDI)
●●
Private Cloud-in-a-box
●●
SQL Server Consolidation
●●
Remote Office/Branch Office
●●
VMware to Hyper-V Migration
Independent scaling of compute and storage Predictable, controllable high performance Easy deployment 50% lower total cost of ownership (TCO) than converged infrastructure 75% smaller footprint with higher VM density than converged infrastructure High-performance, all-flash graphics for VDI
“HyperGrid’s all-flash solution erased all of our issues and beat the competition on performance, fault tolerance, and prices. As far as I’m concerned, HyperGrid’s HCA is perfect for everybody.” — Chad Dixson, IT Manager Yavapai-Prescott Indian Tribe
HyperGrid HyperConverged Appliance
HyperConverged Appliance Specifications All-Flash Compute/Storage Node
All-Flash Compute/Storage Node
All-Flash Compute/Storage Node
All-Flash Storage-Only Node
GS-3000-FCN-90-2-v4
GS-3000-FCN-40-2-v4
GS-3000-FCN-20-2-v4
GS-3000-FSN-20-2-v4
Compute/Storage Nodes
Compute/Storage Nodes
Compute/Storage Nodes
Storage-Only Nodes
Dual Intel Xeon E5-2690 v4 (28 cores, HT, 70MB cache)
Dual Intel Xeon E5-2640 v4 (20 cores, HT, 50MB cache)
Dual Intel Xeon E5-2620 v4 (16 cores, HT, 40MB cache)
Dual Intel Xeon E5-2620 v4 (16 cores, HT, 40MB cache)
From 32GB to 1TB DRAM 16 total slots using 8, 16, 32 or 64GB DRAM
From 32GB to 1TB DRAM 16 total slots using 8, 16, 32 or 64GB DRAM
From 32GB to 1TB DRAM 16 total slots using 8, 16, 32 or 64GB DRAM
32GB DDR4 DRAM
Per Node Hot-Swap Node Type Drive Capacity Processor Memory
960GB or 1,920GB or 3,840GB (SSDs) / 960GB (SED)
NICS
2 x 10GbE RJ45 (on-board)
Hot-Swap Drives Included Software1
Yes
WS 2012 R2 Data Center + HyperGrid Controller Software
Optional Network Cards Optional GPU
WS 2012 R2 Data Center + HyperGrid Controller Software
WS 2012 R2 Data Center + HyperGrid Controller Software
Windows Embedded 7 + HyperGrid Controller Software
2-port 10GbE or 4-port 1GbE RJ45 or 2 port 10GbE SFP+ or 4-port 10GbE SFP+ See FGN data sheet
See FGN data sheet
See FGN data sheet
NA
2U Enclosure with up to 4 Nodes (FCN and/or FSN, FGN not supported) Capacity
Up to 6 SSDs per Node: Up to 5.76TB, 11.52TB, or 23.04TB per node; or 23.04TB, 46.08TB, or 92.16TB per enclosure2
Chassis Dimensions
3.47" H x 17.25" W x 28.5" D; 88 mm H x 438 mm W x 724 mm D
Maximum Weight
90.3 lbs (41.0 kg)
Power
2 Redundant PSUs
Power Consumption**
1,800 Watts maximum; 500 Watts idle
Operating Temperature
10°C to 35°C (50°F to 95°F)
Non-Oper Temperature
-40°C to 65°C (-40°F to 149°F)
2U Enclosure with up to 2 Nodes (FCN, FSN or the HyperGrid Graphics Node FGN, see data sheet for product information) Capacity
Up to 12 SSDs per Node: Up to 11.52TB, 23.04TB, or 46.08TB per node; or 23.04TB, 46.08TB, or 92.16TB per enclosure2
Chassis Dimensions
3.47” H x 17.25” W x 28.5” D; 88 mm H x 438 mm W x 724 mm D
Maximum Weight
85 lbs (38.5 kg)
Power
2 Redundant PSUs
Power Consumption3
1,500 Watts maximum; 500 Watts idle
Operating Temperature
10°C to 35°C (50°F to 95°F)
Non-Oper Temperature
-40°C to 65°C (-40°F to 149°F)
1. On FCN, customer can either deploy their Windows Server 2012 R2 Datacenter License, or have HyperGrid license it at an additional cost. On FSN, Windows Embedded 7 comes licensed. 2. 960Gb self-encrypting drive (SED) is also available 3. Typical power consumption during spin-up / idle under normal operating conditions.
Warranty and Support HyperGrid hardware products come with a 3-year limited hardware warranty. HyperGrid may offer different delivery methods for warranty service, including but not limited to parts and product dispatches and mail-in service. Base-level warranty service is mail-in, which can be changed based on support
and service contracts purchased by the customer. HyperGrid offers a variety of support options, including 24x7x365 worldwide suppor. Visit www.hypergrid.cloud/support for details.
US 855.786.7065 | 650.316.5515 UK +44(0)20 3553 3662
[email protected] | www.hypergrid.com
FOLLOW US © 2016 HyperGrid. All rights reserved. HyperGrid and the HyperGrid logo are trademarks of HyperGrid in the U.S. and other countries. All other trademarks are the property of their respective owners. Information regarding products, services and offerings are subject to change without notice. For the latest information, please visit www.hypergrid.com. 071716