   EMBED


Share

Transcript

HZB12-120 HZB12-120 Valve Regulated Lead Acid battery. 12 year design life for stand by power applications. 12 Volts 120 Ah § Special formation process § Analytical Grade electrolyte § Spill proof / leak proof § Valve regulated Max internal pressure 2.5 psi § Multi-position usage § ABS Case and cover - V0 on request § Low self discharge § FAA and IATA approved as non-hazardous § Built to comply with IEC 8962, DIN 43534, BS 6290 Pt4, Eurobat. Specifications Nominal Voltage Nominal Capacity Design Life Operating Temperature Grid alloy Plates Separator Active material Case and cover Charge Voltage Electrolyte Venting Valve RE LE AD Terminal Torque setting Cables TU RN RUBBISH BIN RECYCLE Pb 12 Volts 120Ah (C20 @ 20 oC) 12 Years -20 °C to 50 °C Calcium / Tin lead alloy Flat Pasted Absorbant Glass Mat Very high purity lead ABS (VO on request) Float 2.25 - 2.30 VPC @25 °C Cycliing 2.35 @25 °C Max. 2.4 VPC Max ripple 0.05C (A) Sulphuric acid Analytical grade purity EPDM Rubber 1.5 to 2 psi (10.5 - 14 KPa) release pressure. Resealing at 1 psi (7 KPa) Insert 16mm Dia M6 thread. Epoxy sealed by extended mechanical paths The recommended torque value for all types is 5-7 Nm Connectors, cables, terminal covers on request. Haze Battery Company keenly encourages environmental awareness; PLEASE follow guidelines for the recycling /disposal of lead. Website: www.hazebattery.com E mail : [email protected] PRODUCT SHEET HZB12-120 Completely maintenance free, sealed construction eliminates the need for watering Sealed Lead Acid 12 Volt Bloc § AGM Range Innovative Features 12V AGM 3 A R10 10 R3 Specifications 227 mm 8.94 inches (Inc. terminals) n/a mm n/a inches Length 408 mm 16.06 inches Width 176 mm Weight 37 Kg 6.93 inches 16 Dimensions 122 120 Ah A-A 12V Nominal Voltage Nominal Capacity Total Height 81.77 lbs A Characteristics 20 112.2 Ah 5 hour rate 97.7 Ah 1 hour rate 77.6 Ah 15 min rate 52.2 Ah 3 mOhms Internal Resistance 1250 S Impedance 40 oC (104 oF) o Self-Discharge 20 oC (68 oF) 102% o 20 C (68 F) 100% 0 oC (32 oF) 85% -15 oC (5 oF) 65% Capacity after 1 months storage 98% Capacity after 3 months storage 94% Capacity after 6 months storage 86% Short Circuit Current 20 oC (68 oF) 408 Capacity correct ion for Temperature Variations (C20) 25 Capacity 20-25 oC (68-77 oF) To 1.7 volts 176 122.5 Ah 10 hour rate To Terminal 206 20 hour rate Standard Optional 16mm Insert M6 t hread Cu/Lead Flag - J Type - Auto Cyclic 2.35 - 2.40 VPC (20-25 C) o 48.5 Charging (Constant Voltage) o 2.27 - 2.30 VPC (15-25 C) Float Battery 227 Terminal 48.5 3300 Constant Power Discharge - Watts per Cell @ 20-25 °C End V per Cell 5M 10M 15M 20M 25M 30M 35M 40M 45M 60M 90M 2 hr 3 hr 4 hr 5 hr 6 hr 7 hr 8 hr 10 hr 12 hr 20 hr 1.85 473 386 327 284 250 223 201 183 169 136 99 77.5 54.1 41.4 34.6 29.6 26.2 23.4 19.5 16.7 11.0 1.80 546 424 353 301 262 233 209 190 175 141 101 78.9 54.8 42.0 35.2 30.2 26.6 23.8 19.8 17.0 11.2 1.75 589 443 366 310 269 239 213 194 178 143 103 79.9 55.5 42.4 35.6 30.6 26.9 24.1 20.0 17.2 11.4 1.70 615 459 374 314 272 242 217 196 180 145 104 80.5 55.9 42.9 35.8 31.0 27.2 24.4 20.2 17.4 11.6 1.67 629 466 378 317 274 243 218 197 181 145 104 80.9 56.1 42.9 - - - - - - - 1.65 642 474 381 319 275 244 219 199 182 146 105 81.2 56.2 43.0 - - - - - - - 1.60 673 486 389 325 279 247 222 201 184 147 105 81.6 56.5 43.2 - - - - - - - Constant Amps Discharge - Amps @ 20-25 °C End V per Cell 5M 10M 15M 20M 25M 30M 35M 40M 45M 60M 90M 2 hr 3 hr 4 hr 5 hr 6 hr 7 hr 8 hr 10 hr 12 hr 20 hr 1.85 259 213 180 156 135 120 108 98.6 90.3 72.8 52.1 40.7 28.7 22.6 18.6 16.0 14.1 12.7 10.6 9.12 5.73 1.80 309 240 196 165 143 126 112 102 93.6 74.8 53.3 41.6 29.2 22.9 18.9 16.3 14.4 13.0 10.9 9.35 5.90 1.75 332 255 203 170 147 129 115 105 95.6 76.3 54.4 42.3 29.6 23.2 19.2 16.6 14.7 13.2 11.1 9.49 5.97 1.70 349 265 209 174 150 132 117 106 97.2 77.6 55.0 42.8 30.0 23.6 19.5 16.8 14.9 13.4 11.2 9.66 6.13 1.67 358 268 212 176 151 133 118 107 97.7 78.0 55.2 42.9 30.1 23.6 - - - - - - - 1.65 366 270 214 177 152 133 119 107 98.1 78.4 55.5 43.1 30.2 23.7 - - - - - - - 1.60 385 279 218 180 154 135 120 108 99.2 78.9 56.0 43.4 30.4 23.8 - - - - - - - Ampere Hour @ 20-25 °C End V per Cell 2 hr 3 hr 4 hr 5 hr 6 hr 7 hr 8 hr 10 hr 12 hr 20 hr 1.85 78.2 81.4 86.2 89.6 93.1 96.2 98.5 1.80 1.75 1.70 83.2 84.7 85.6 87.5 88.9 90.1 90.9 92.2 93.6 94.6 96.1 97.7 97.7 100.7 103.8 99.4 102.6 106 101.0 104 107 1.67 85.9 90.3 93.8 - - - 1.65 86.2 90.6 94.1 - - 1.60 86.8 91.2 94.7 - - 101.5 106 109 109 111 112 112 114 116 118 119 123 - - - - - - - - - - - - - - R UL Recognised Component MH28512 EMC Germany tested 220311