Transcript
HZB6-110 HZB6-110 Valve Regulated Lead Acid battery. 12 year design life for stand by power applications. 6 Volts 110 Ah
§
Fully tank formed plates
§
Analytical Grade electrolyte
§
Spill proof / leak proof
§
Valve regulated Max internal pressure 2.5 psi
§
Multi-position usage
§
ABS Case and cover - V0 on request
§
Low self discharge
§
FAA and IATA approved as non-hazardous
§
Built to comply with IEC 8962, DIN 43534, BS 6290 Pt4, Eurobat.
Specifications Nominal Voltage Nominal Capacity Design Life Operating Temperature Grid alloy Plates Separator Active material Case and cover Charge Voltage Electrolyte Venting Valve
RE
LE
AD
Terminal Torque setting Cables
TU RN
RUBBISH BIN
RECYCLE
Pb
6 Volts 110Ah (C20 @ 20 oC) 12 Years -20 °C to 50 °C Calcium / Tin lead alloy Flat Pasted Absorbant Glass Mat Very high purity lead ABS (VO on request) Float 2.25 - 2.30 VPC @25 °C Cycliing 2.35 @25 °C Max. 2.4 VPC Max ripple 0.05C (A) Sulphuric acid Analytical grade purity EPDM Rubber 1.5 to 2 psi (10.5 - 14 KPa) release pressure. Resealing at 1 psi (7 KPa) Insert 12mm Dia M5 thread. Epoxy sealed by extended mechanical paths The recommended torque value for all types is 5-7 Nm Connectors, cables, terminal covers on request.
Haze Battery Company keenly encourages environmental awareness; PLEASE follow guidelines for the recycling /disposal of lead.
Website: www.hazebattery.com E mail :
[email protected]
PRODUCT SHEET HZB6-110
Completely maintenance free, sealed construction eliminates the need for watering
Sealed Lead Acid 12 Volt Bloc
§
AGM Range
Innovative Features
6V AGM
Specifications 6V 110 Ah 205 n/a 193 168 16
To Terminal 207
mm mm mm mm Kg
8.07 n/a 7.60 6.61 35.36
inches inches inches inches lbs
162.0
Nominal Voltage Nominal Capacity Total Height (Inc. terminals) Dimensions Length Width Weight
Characteristics
20 To
12.0
33.0
146
A-A
Short Circuit Current 20 oC (68 oF)
34.0
20
A
Self-Discharge o C (68 oF)
20
16
Capacity correction for Temperature Variations (C20)
12.0
20 hour rate 112.0 Ah 10 hour rate 98.3 Ah 5 hour rate 87.5 Ah 1 hour rate 71.2 Ah 15 min rate 52.6 Ah Internal Resistance 4 mOhms Impedance S 40 oC (104 oF) 102% 20 oC (68 oF) 100% 0 oC (32 oF) 85% -15 oC (5 oF) 65% Capacity after 1 months storage 98% Capacity after 3 months storage 94% Capacity after 6 months storage 86%
192.0
Capacity o C (68 oF) 1.7 volts
Battery 204
3200
Float
2.27 - 2.30 VPC (15-25 oC)
R10
2.35 - 2.40 VPC (20-25 oC)
R3
Cyclic
Charging (Constant Voltage)
A
14mm Insert M6 thread Cu/Lead Flag - J Type - Auto
3
Standard Optional
10
Terminal
Constant Power Discharge - Watts per Cell @20 oC End V per Cell
5M
10M
15M
20M
25M
30M
35M
40M
45M
60M
90M
2 hr
3 hr
4 hr
1.85 1.80 1.75 1.70 1.65 1.60
470 581 594 616 647 674
384 454 481 484 492 507
317 359 378 382 387 399
273 298 314 319 322 326
239 261 269 273 276 277
216 230 233 236 239 242
193 202 206 209 211 213
174 184 187 188 191 193
158 168 170 171 173 174
126 133 134 135 136 137
93.4 94.9 95.4 96.9 97.9 99.2
73.3 74.4 74.9 76.3 76.6 77.0
51.0 51.7 51.7 53.2 53.3 53.6
39.2 39.9 40.0 41.2 -
Constant Amps Discharge - Amps @20 oC End V per Cell
5M
10M
15M
20M
25M
30M
35M
40M
45M
60M
90M
2 hr
3 hr
4 hr
5 hr
8 hr 10 hr 12 hr 20 hr
1.85 1.80 1.75 1.70 1.65 1.60
252 317 328 342 362 378
205 247 264 268 273 283
169 194 206 210 213 220
145 161 170 174 176 179
127 140 145 148 150 151
114 123 125 127 129 131
101 108 110 112 114 115
91.7 97.3 99.3 101 102 104
82.9 88.6 90.0 91.1 92.6 93.2
65.9 69.6 70.4 71.2 71.9 72.4
48.4 49.5 49.9 50.9 51.5 52.2
37.8 38.6 39.0 39.8 40.0 40.3
26.1 26.6 26.8 27.6 27.7 27.8
20.0 20.5 20.6 21.3
16.3 16.9 17.0 17.5
11.2 11.5 11.6 11.9
9.18 9.49 9.55 9.83
7.85 8.12 8.17 8.41
5.22 5.42 5.44 5.60
-
-
-
-
-
-
o
Ampere Hour @20 C End V per Cell 1.85 1.80 1.75 1.70 1.65 1.60
2 hr
3 hr
4 hr
5 hr
8 hr 10 hr 12 hr 20 hr
75.6 77.2 77.9 79.6 80.1 80.6
78.3 79.9 80.3 82.7 83.0 83.5
80.0 81.8 82.4 85.1 -
81.7 84.5 84.9 87.5 -
89.8 92.1 92.9 95.6 -
91.8 94.9 95.5 98.3 -
94.2 97.4 98.0 101 -
104 108 109 112 -
R
UL Recognised Component MH28512
EMC Germany
tested