HZY12-44 HZY12-44 Valve Regulated Lead Acid battery. 12 year design life for stand by power applications. 12 Volts 44 Ah (C20) § Fully tank formed plates § Analytical Grade electrolyte § Spill proof / leak proof § Valve regulated Max internal pressure 2.5 psi § Multi-position usage § ABS Case and cover - V0 on request § Low self discharge § FAA and IATA approved as non-hazardous § Built to comply with IEC 8962, DIN 43534, BS 6290 Pt4, Eurobat. Specifications Nominal Voltage Nominal Capacity Design Life Operating Temperature Grid alloy Plates Separator Active material Case and cover Charge Voltage Electrolyte Venting Valve RE LE AD Terminal TU RN RUBBISH BIN RECYCLE Pb 12 Volts 44Ah (C20 @ 20 oC) 12 Years -20 °C to 50 °C Calcium / Tin lead alloy Flat Pasted Microporous polymer Very high purity lead ABS (VO on request) Float 2.25 - 2.30 VPC @25 °C Cycliing 2.35 @25 °C Max. 2.4 VPC Max ripple 0.05C (A) Gelled Sulphuric acid Analytical grade purity EPDM Rubber 1.5 to 2 psi (10.5 - 14 KPa) release pressure. Resealing at 1 psi (7 KPa) Epoxy sealed by extended mechanical paths Haze Battery Company keenly encourages environmental awareness; PLEASE follow guidelines for the recycling /disposal of lead. Website: www.hazebattery.com E mail : [email protected] PRODUCT SHEET HZY12-44 Completely maintenance free, sealed construction eliminates the need for watering Sealed Lead Acid 12 Volt Bloc § GEL Range Innovative Features 12V Gel inches inches inches inches lbs 3 R10 6 6.69 n/a 7.76 6.50 30.94 A-A mm mm mm mm Kg A 12V 44 Ah 170 197 165 14 61 Nominal Voltage Nominal Capacity Total Height (Inc. terminals) Length Dimensions Width Weight R3 Specifications Characteristics Self-Discharge 20 oC (68 oF) Short Circuit Current 20 oC (68 oF) 12 20 A 25 197 Capacity correction for Temperature Variations (C20) Ah Ah Ah Ah Ah mOhms S 102% 100% 85% 65% 98% 94% 86% 25 Capacity 20 oC (68 oF) To 1.7 volts 39.7 35.5 31.3 26.0 18.7 7.5 To Terminal 168 20 hour rate 10 hour rate 5 hour rate 1 hour rate 15 min rate Internal Resistance Impedance 40 oC (104 oF) 20 oC (68 oF) 0 oC (32 oF) -15 oC (5 oF) Capacity after 1 months storage Capacity after 3 months storage Capacity after 6 months storage Terminal Standard Optional 14mm Insert M6 thread Cu Flag Charging (Constant Voltage) Cyclic Float 2.35 - 2.40 VPC (20-25 oC) 2.27 - 2.30 VPC (15-25 oC) 165 1400 Battery 170 o Constant Power Discharge - Watts per Cell @20 C End V per Cell 1.85 1.80 1.75 1.70 1.65 1.60 5M 10M 15M 20M 25M 30M 35M 40M 45M 60M 90M 2 hr 3 hr 4 hr 177 189 197 203 207 213 145 158 166 169 171 173 26.3 27.1 27.2 27.5 - 18.2 18.6 18.8 19.1 - 13.9 14.4 14.5 14.7 - 5M 10M 15M 20M 25M 30M 35M 40M 45M 60M 90M 2 hr 3 hr 4 hr 94.9 103 109 113 116 120 77.5 85.9 91.0 93.6 95 97 119 128 134 136 138 140 100 107 109 111 112 113 86.8 92.0 93.8 94.4 95 96 76.7 80.6 82.3 82.6 83.1 84.0 69.4 72.5 73.2 73.4 73.9 74.5 63.1 65.4 65.9 66.1 66.8 67.7 58.2 59.8 60.1 60.9 61.4 61.8 47.1 48.3 48.3 49.2 49.5 49.8 33.6 34.4 34.5 35.0 35.3 35.6 Constant Amps Discharge - Amps @20 oC End V per Cell 1.85 1.80 1.75 1.70 1.65 1.60 63.2 69.5 73.1 74.7 76.1 77.5 53.2 57.4 59.1 60.7 61.2 61.8 46.0 49.3 50.6 51.3 51.8 52.4 40.5 43.0 44.2 44.6 45.0 45.6 36.6 38.6 39.1 39.5 39.8 40.2 33.2 34.6 35.0 35.4 35.8 36.4 30.5 31.6 31.9 32.5 32.8 33.1 24.6 25.3 25.5 26.0 26.2 26.4 17.4 17.9 18.0 18.3 18.6 18.7 5 hr 8 hr 10 hr 12 hr 20 hr 13.6 9.32 7.10 5.85 3.96 14.0 9.6 7.36 6.06 4.10 14.1 9.7 7.45 6.12 4.15 14.4 9.9 7.59 6.26 4.26 - - - - - 3.32 3.41 3.45 3.55 2.84 2.93 2.96 3.04 1.85 1.92 1.93 1.99 - - - Ampere Hour @20 oC End V per Cell 1.85 1.80 1.75 1.70 2 hr 3 hr 4 hr 5 hr 8 hr 10 hr 12 hr 20 hr 27.1 28.1 28.3 28.7 28.0 28.7 29.1 29.7 28.4 29.4 29.8 30.4 29.2 30.3 30.6 31.3 31.7 32.8 33.2 34.0 33.2 34.1 34.5 35.5 34.1 35.2 35.5 36.5 37.0 38.3 38.6 39.7 R UL Recognised Component MH28512 EMC Germany tested