Preview only show first 10 pages with watermark. For full document please download

I 15 14 12 10 9 6 3 2 1 C

   EMBED


Share

Transcript

3 2 460-60-3 1 L1 Red/White 460V Phase Monitor Green Yellow T3 L2 T2 T2 L1 T1 T1 Terminal Block #4 L2 1 2 3 4 5 Indoor Blower Motor 3 460 T. Block #2 R 59 Comp. Contactor LO 70 41 Yel/Blk L1 L2 L3 68 26 30 R B L2 RV Y L CC L1 C C COM Defrost Control 51 SEN JMP SENSOR Red 57 Red Yellow Terminal Block #3 10 Terminal Block #7 73 S C Compressor Low Pressure Switch Defrost Sensor Reversing Valve 460 Transformer #2 230 Red High Press. Switch A T2 3 Term. Block #3 CC Compressor Term. Contactor Term. Defrost Control Block Block #5 #5 Y RV B RV W2 6 7 9 4 Electric Heat Relay (Opt.) Electric Heat Relay T. Block #2 Reversing Valve C Low Ambient Bypass Heater Contactor #2 Heater Contactor #1 C C D T. Block #1 O1 7 Y F 5 1 Plug #2 A A L. A. Control (Opt.) L. A. Bypass (Opt.) T. Block #2 3 T1 COM L D O. Motor Controller 1 W2 2 10 H LO T. Block #2 Pressure Lockout Indicator 11 Grn Black Gnd L2 Defrost Sensor NC 3 Red Red Tan Purple/White Blue L1 B2 Red 12 Black 12 R Outdoor Fan Motor Controller B1 C RV TWV Black 12 Black Low Ambient Control (Opt.) S SENSOR L2 B 6 79 Terminal Block #6 Black H 7 S 76 Black Blk L0 39 Blue Brown Yellow T1 T2 L1 Black Black/White Tan LC Blue Black 5 42 Black/White T2 35 Terminal Block #5 11 42 Blue 4 Yellow 6 Red Black 2 T3 44 46 Blue T1 Red/Black Terminal 9 Block #4 28 Red Low Ambient Bypass (Opt.) Blue 1 Black 3 45 Blue/Black 47 Black/White Blue Ground 69 Red COM Blue/Red C Yo C 9 1 2 3 83 Fuse Block R C T. Block #2 67 Red/White Y 8 64 SENSOR L1 Low Pressure Term. Block Control #5 L 27 37 29 TERM SPEED TEMP UP 30 60 90 Black 40 LC Phase Monitor 2 1 Black 460V 32 R W2 NC Black R Black 66 Yellow 27 Yo Y C Transformer 60 36 Red Red/White Phase Monitor 72 58 Blk/Whte Blk/Whte Yellow Black/White 27 Y1 L0 Upper Control Panel T3 38 Yellow L1 Yellow/Red R. Vent Opt. Only T2 Term. Block High Pressure #5 Control T. Block #1 Lower Control Panel 48 T1 L3 Red 49 L2 Plug #1 C Y 56 Black Yellow/Red Pink L1 78 80 R TWV 12 50 1 Transformer 24VAC I 77 Yellow/Red Pink 2 COM Term. Block #5 63 L Yellow C Condenser Section Blk/Whte R Brown Blue W2 Blk/Whte Brown B 43 F Pressure Lockout Indicator 61 Red/Whte Blue Yellow Y G2 4 T1 L1 L1 L2 L3 10 33 G T2 Outdoor Fan Motor Controller 31 11 Terminal Block #2 T3 T3 Term. Block #7 Yellow Red Black 3 Red 2 L3 Transformer Black 1 Black/White L3 Orange Orange Red/Yellow Blk/Whte Brown Brown Blk/Whte Blue Black 25 Plug #3 Brown/White 3 4 5 6 7 8 9 10 11 12 L2 L1 Compressor Compressor Contactor L3 240V 6 L2 Orange Pink 15 14 12 10 9 Blk/Whte 1 2 Red/Whte Brn/Whte 24 Plug #2 Indoor Blower Motor 23 Purple I O1 Y Y1 C Red/Whte Terminal Block #1 ("A" Ctrl. Opt. Only) 1 2 3 B C T. Block #2 D Labeled wires connect if no options used. Factory Low Voltage G G2 Indoor Blower Motor Plug #3 Install jumper for hi speed blower oper. on F models 36, 42, 48, and 60. Remove jumper when Low Amb. Bypass is H installed. High Voltage T. Block #2 1 3 2 9 6 14 12 10 15 Field Optional I Remove jumper when CS2000 Energy Monitor is installed. ! WARNING USE COPPER CONDUCTORS ONLY SUITABLE FOR AT LEAST 75° C. ! DANGER *ELECTRICAL SHOCK HAZARD *DISCONNECT POWER BEFORE SERVICING. Bard Mfg. Co. Bryan, Ohio 4100-318 A