Transcript
4
3
2
1
Rev
D
D
Coax Out
Coax Out Mounting Flanges
12VDC INPUT Use included Power Supply In: 120VAC/1.2A: 240VAC/.6A Out: 12VDC, 60W, 5.0A
12VDC INPUT Use included Power Supply In: 120VAC/1.2A: 240VAC/.6A Out: 12VDC, 60W, 5.0A C
MPCW-6 (1st & 2nd Gen) with coax daisy chain output to next device Option: Series 7 Receiver can be added to this config
MPCX with coax daisy chain output to next device option: Series 7 Receiver can be added to this config
Coax Out
B
B
Remove screws from face of lid and attach MPCX2 receiver using same screws
Series 7 Receiver with coax daisy chain output to next device Option: Coax Input
Please Note: -Systems w/ multiple signal inputs will use whichever signal is present 1st. The 1st signal must be turned off for the equipment to start using 2nd signal. -To maintain reliable wireless connection there must be clear line of sight between the transmitter and all receivers in the system. 4
C
12VDC INPUT Use included Power Supply In: 120VAC/1.2A: 240VAC/.6A Out: 12VDC, 60W, 5.0A
12VDC INPUT Use included Power Supply In: 120VAC/1.2A: 240VAC/.6A Out: 12VDC, 60W, 5.0A
A
A
3
Coax input with coax daisy chain output to next device
IAD-2 Indoor Accessory Driver Signal Input/Output Configurations Drawn 2
KAB
Date
3/28/2016
A
Nevco, Inc. Greenville, Illinois 62246 Drawing No. Sheet
of
1
275-0803 2 1
4
3
2
1
Rev
A
SSC-T5/T9 D
D
SSC
9715 #8
9715 #7
9715 #6
9715 #5 C
9715 #4 9715 #3 9715 #2 9715 #1 Use standard 8 conductor, 24 gauge Straight-Thru "Patch"
B
10ft Cable
style Ethernet cables to connect 9715 clocks together. Max Chain Length for number of clocks = 325'(1), 275'(2),225'(3),175'(4) DO NOT USE CROSSOVER CABLES DO NOT CONNECT IAD or 9715 TO COMPUTER NETWORK Ethernet (patch cables) extensions available. -25ft Nevco Part #603-2689 -50ft Nevco Part #603-4970 -100ft Nevco Part #603-4971 -150ft Nevco Part #603-4972 1. Orange Stripe / White -200ft Nevco Part #603-4973 2. 3. 4. 5. 6. 7. 8.
Bottom of RJ-45 crimp on connector
Orange Solid Green Stripe / White Blue Solid Blue Strip / White Green Solid Brown Strip / White Brown Solid
Patch Cable pinout (TIA T568B Standard) Both ends of Ethernet cable should match each other * IAD max. input current at 120VAC is 0.5Amps IAD output power limit 5.0 Amps @ 12vDC Device Description
A
10ft Cable
C
12vDC Amps Max Devices Total Amps # Outputs per Device per output per output 1.2 2 0.3 4 Locker Room Clocks (SSC) Slim Shot Clocks 0.4 4 1 1.6 (SSC-T5) Shot Clocks 2.8 0.7 4 1 (SSC-T9) Shot Clocks 1.0 4 4.0 1 Horns 2 0.6 1 0.6 1.2 1.2 EOPs 1 1 4
3
EOP #1
25ft Cable
Horn #1
Combine 10ft & 25ft cables to connect IAD to EOP. 14 gauge extensions available. -25 foot Nevco Part #603-2372 -50 foot Nevco Part #603-3032 -100 foot Nevco Part #603-3033 -150 foot Nevco Part #603-3034 -200 foot Nevco Part #603-3035
B
Horns mounted in Horn #2 external box
IAD-2 Indoor Accessory Driver Accessory Output Configurations Drawn
KAB
2
Date
3/28/2016
A
Nevco, Inc. Greenville, Illinois 62246 Drawing No. Sheet
2
of
275-0803 2 1