Preview only show first 10 pages with watermark. For full document please download

Ibanet750-bm - Iba Lat Brasil

   EMBED


Share

Transcript

Hardware Software Training Applications ibaNet750-BM In brief ■■ Decentralized input and output system ■■ Bus connection for WAGO-I/O-System 750 ■■ 32 analog inputs and outputs per station ■■ 32 digital inputs and outputs per station ■■ Line topology for input and output functions ■■ Ring topologies for input and output processes ■■ Stand-alone mode ■■ Interface control ■■ Robust plastic enclosure ■■ Assembly on the mounting rail Characteristics ibaNet750-BM is a device designed to extend the iba I/O functionality range using the I/O modules series 750 produced by WAGO/Beckhoff. The device acts as a gateway between the serial KBUS and the deterministic fiber optic ibaNet network. The device is mostly used in ibaLogic Soft-PLC applications. ibaNet750-BM is the ideal supplement for the range of the peripheral devices. Incremental encoders, SSI-inputs, RTDs, thermocouples and measuring bridges can be integrated into these processes. Different actuator outputs are available. Realization of a variety of applications Characteristics of fiber optical interface ■■ I/O-expansion for VMEbus systems with ibaLink-SM128V-i-2o master interfaces (ring or star) ■■ Performs input and output functionality at the same time ■■ Star- and ring topology, can also be used to replace bundles of copper wiring without a PC involved (ring) ■■ Process data acquisition in star-shaped topology with daisy-chain of devices (like ibaPADU-8) ■■ I/O system for ibaLogic Soft-PLC (ring) ■■ I/O-expansion of Siemens Simatic S5 115U, 135U, 155U and 150U with ibaLink-SM-64-io as master interface (needs only 1 slot within the rack) ■■ I/O-expansion of Siemens Simicro MMC216 with ibaLink-SM-64-io ■■ Replacement for copper wires (up to 8 x 136 binary signals in each direction) with only 2 optical fibers over up to 1.28 mls (2 km) distance between single devices ■■ 32 + 32 analog inputs/outputs plus 32 + 32 binary inputs/ outputs per device ibaNet750-BM devices are usually connected to ibaFOB-4i resp. ibaFOB-4o cards which are installed in a PC. These intelligent fiber optic interface cards provide the process image in a dual-ported ram. The software (e. g. ibaPDA) may read and write the data in its own scan cycle down to 1 ms. ■■ Or up to 512 + 32 binary inputs plus 512 + 32 binary outputs The following devices exist within the large I/O product family of iba ■■ Or 8 complex terminals, e.g. SSI or incremental encoders + 32 binary inputs plus 8 binary outputs ■■ ibaPADU-8 (±10 V inputs) ■■ Integrated power supply for I/O-modules (max. 1.5 A internal load) ■■ ibaPADU-8-I (±20 mA inputs) ■■ Up to 1.28 mls (2 km) distance between devices ■■ Up to 8 device addresses per ring or star; fiber optic compatible to ibaPADU-8 and ibaPADU-8-O ■■ There are restrictions in combination with ibaPDA concerning the sampling time of the terminals. Due to the internal serial bus of the device (KBUS) no simultaneous process image can be guaranteed below 10 ms sampling time (ibaPADU-8 guarantees 1 ms) ■■ Device can be used as copper wire replacement without a PC involved ■■ All devices on the ibaNet bus will be updated in exact 1 ms cycles ■■ ibaPADU-8-HI (±10 V, 500 Ω) ■■ ibaPADU-16 (16A & 16D) ■■ ibaPADU-32 (32A & 32D, table version) ■■ ibaPADU-32-R (19”rackmount version) ■■ ibaPADU-8-O (output device for open and closed loop control applications) ■■ ibaBM-FOX-i-3o splits 1 optical input to 3 optical outputs, signal regenerations for distances greater than 1.28 mls (2 km) ■■ ibaBM-SLM (SIMOLINK monitor) ■■ ibaBM-DDCSM (ABB DDCS bus monitor) ■■ ibaLink-SM-64-io (SIMATIK S5 (all), MMC216 and ibaLink-SM-128V-i-2o (VME buses) www.iba-ag.com Technical data Description ibaNet750-BM, Coupling system for WAGO I/O-System 750 Order number 15.140000 Dimensions 1.97 inch x 3.94  inch x 3.15 inch (50 mm x 100 mm x 80 mm) Weight (incl. packaging) 0.3 kg Power supply DC +24 V (±10 %), 24 V load power supply external Current consumption – integrated 24 V supply 80 mA ±20 % operating, cold start consumption up to 4 times higher (without load power supply and without terminals) Temperature conditions 32 °F to 122 °F (0 °C to 50 °C) (In use)/-13 °F to 149 °F ( -25 °C to 70 °C) (Storage) I/O-modules Binary inputs (BI) Typ. 32 BI Maximum: 32 + up to 512 BI Max. by replacing 32 analog inputs (1 AI = 16 BI, interpretation with ibaLogic only) Order number Module type Short description 15.144000 ibaNet750-BM 2-Chan DI 3 ms 2-Channel Digital Input 24 V, 3 ms input filter 15.144010 ibaNet750-BM 2-Chan DI 0.2 ms 2-Channel Digital Input 24 V, 0.2 ms input filter 15.144020 ibaNet750-BM 4-Chan DI 3 ms 4 Channel Digital Input 24 V, 3 ms input filter 15.144030 ibaNet750-BM 4-Chan DI 0.2 ms 4 Channel Digital Input 24 V , 0.2 ms input filter Analog Inputs (AI) Maximum 32 AI Each unused analog input can be replaced by 16 digital inputs 15.144560 ibaNet750-BM 2-Chan AI 2-Channel analog input; ±10 V differential input 15.144610 ibaNet750-BM 2-Chan PT100 2-Channel analog input RTD (all types) 15.144620 ibaNet750-BM 2-Chan Thermo couple 2-Channel thermo couple inputs (all types) Binary Outputs (BO) Typical 32 BO Maximum: 32 + up to 512 BO Max. by replacing 32 analog inputs (1 AO = 16 BO, interpretation with ibaLogic only) 15.145010 ibaNet750-BM 2-Chan DO 0.5 A 2-Channel digital output 0.5 A/24 V 15.145020 ibaNet750-BM 2-Chan DO 2 A 2-Channel digital output 2 A/24 V 15.145040 ibaNet750-BM 4-Chan DO 0.5 A 4-Channel digital output 0.5 A/24 V Analog Outputs (AO) Maximal 32 AO 15.145560 ibaNet750-BM 2-Chan AO Analog output ±10 V Complex Terminals Maximum 8 A complex terminal replaces 4 analog inputs (= 2 modules) 15.146300 ibaNet750-BM SSI Input SSI input module 1 channel 15.146310 ibaNet750-BM Incr. Encoder Incremental encoder 0 degrees/90 degrees, 1 channel 15.146000 ibaNet750-BM End-Terminal End-terminal for ibaNet750-BM, always needed 15.146120 ibaNet750-BM Power Supply Supply terminal 230 V/24 V 15.146140 ibaNet750-BM Power Distr. Mod Power supply distribution module ibaLink-SM-64-io ibaLink-SM-128V-i-2o Diverse terminals Front view and connectors S1: Device address (1..B), S2: Device mode, (0 = Run; 1 = Ring master; F = Ring slave) Fiber optic connectors 2 connectors ST-type Transmitter and receiver Power supply DC 24 V, 6 to 9 V Aux.-power (optical ring buffering) 2 pole jack (Phoenix) Status displays LEDs: Run (Green) Link (Yellow) Error (Red) (for ibaNet bus side) IO Error (Red) and IO Run (Green) (for module bus side (KBUS)) Data transmission Transmission speed 3.3 Mbit/s Net data per block Max. 64 analog plus 64 binary signals per link Update rate 1 ms (64 + 64 signals/ms) ibaFOB-4o Note: The range of available module types is beeing extended continuously! iba AG Koenigswarterstr. 44 • 90762 Fuerth • Germany • Phone: +49 911 97282 0 • Fax: +49 911 97282 33 • E-Mail: [email protected] • www.iba-ag.com Messtechnik- und Automatisierungssysteme Measurement and Automation Systems Flyer_ibaNet750-BM_v1.4_en 02/2013 Technical changes reserved Decade switches