Preview only show first 10 pages with watermark. For full document please download

Ibm Hardware Neuigkeiten Storage

   EMBED


Share

Transcript

Business Breakfast mit IBM IBM Hardware Neuigkeiten Storage ©2013 IBM Corporation The Storwize Family SAN Volume Controller Manuel Schweiger – IT Specialist [email protected] Flex System V7000 Storwize V7000 Unified Storwize V7000 Storwize V3700 Business Breakfast mit IBM ©2013 IBM Corporation Meet The Storwize Family One code base on all platforms One set of functions (selectively licensed) One user interface One CLI  SAN Volume Controller Flex System V7000 Storwize V7000 Unified Storwize V7000 Storwize V3700 Business Breakfast mit IBM 3 ©2013 IBM Corporation 3 Storwize V7000 Overview  Enclosures contain up to twelve 3.5” or twenty-four 2.5” drives in just 2U Modular Hardware Building Blocks in 2U  Control enclosure: dual active-active controllers and drives; Expansion enclosure: drives only  Up to nine expansion enclosures attach to one control enclosure 2U  Mix drive sizes and HDD/SSD in enclosure  Eight 8Gbps FC ports plus four 1Gbps iSCSI ports per controller pair; 16GB cache per controller pair Software inherited from prior offerings plus enhancements New advanced software functions Proven IBM software functionalities  New GUI (easy-to-use, web based)  Easy Tier (dynamic HDD/SSD management)  RAS services and diagnostics  RAID 0, 1, 5, 6, 10  Additional host, controller and ISV interoperability  Storage virtualization (internal and external disks)  Integration with IBM Systems Director  Non-disruptive data migration  Enhancements to TPC, FCM and TSM support  Global & Metro Mirror  FlashCopy up to 256 copies of each volume 4 Business Breakfast mit IBM  Thin provisioning ©2013 IBM Corporation 4 Start Small and Grow Easily Scale Up Easily add up to 9 expansion enclosures Drive choices  2.5-inch (SFF) 146GB 15K RPM SAS 300GB 15K RPM SAS 600GB 10K RPM SAS 900GB 10K RPM SAS 1TB 7.2K RPM NL-SAS  3.5-inch (LFF) – 3TB 7,200 RPM NL-SAS  Solid-State (SFF) – 200GB SAS – 400GB SAS Expand capacity up to 240TB Grow Big – – – – – Drive sizes can be intermixed in an enclosure 12- and 24-bay expansion enclosures can be intermixed in a system 20 U = 1 M Start small One 24-bay control enclosure Availability: Cluster 4 Systems for up to 960 discs Business Breakfast mit IBM 5 ©2013 IBM Corporation 5 Scale the Storwize V7000 Multiple Ways Storwize V7000 One I/O Group System Control Enclosure Control Enclosure Expand Cluster Expand Control Enclosure Storwize V7000 2-4 I/O Groups Clustered System No interconnection of SAS chains between control enclosures as control enclosures communicate via FC and must use all 8 FC ports on enclosures Expansion Enclosures Expansion Enclosures Expansion Enclosures  An I/O Group is a control enclosure and its associated SAS attached expansion enclosures  Clustered system can consist of 2-4 I/O Groups  Scale capacity/throughput 4x – Up to 1.4PB raw capacity or 960 drives in two 42U racks  Non-disruptive upgrades – From smallest to largest configurations – Purchase hardware only when you need it Cluster • No extra feature to order and no extra charge for a clustered system • Configure one system using USB stick and then add second using GUI An I/O Group is a control enclosure and its associated SAS connected expansion enclosures Business Breakfast mit IBM  Virtualize storage arrays behind Storwize V7000 for even greater capacity and throughput ©2013 IBM Corporation 6 Fresh New User Interface Based on the well-received XIV interface System recommendations Visual task flow guidance Integrated video instruction Link to more information if needed 7 Business Breakfast mit IBM System status always available ©2013 IBM Corporation 7 V7000 Unified - Upgrade • 6 up to 24 RU solution – When clustering multiple Storwize V7000 storage modules via a redundant SAN fabric (via FCP or FCoE), we are be able to scale up to 84 RU (+ SAN connectivity) • • • File modules are provided in a pair (cluster) Same code as SONAS Each file module has all functions – Management node  a node is active while the other is standby – Interface node  both nodes are active – Storage node  both nodes are active and directly attached to Storwize V7000 • • Direct redundant LAN connectivity between both file modules All NAS functions are included with the hardware upgrade – no single protocol charges are necessary. – Includes: CIFS, NFS, FTP, HTTP, SCP, Async Replication, ACE Business Breakfast mit IBM ©2013 IBM Corporation 8 Real-time Compression – Basics • Compression is an alternative to Thin Provisioning – They both allow you to use less physical space on disk than is presented to the host • A Compressed Volume is “a kind of” Thin Provisioning – Only uses physical storage to store compressed data – Volume can be built from a pool using internal or external MDisks • Compression requires the I/O group hardware be one of the following platforms – SVC Model 2145-CF8/CG8 Nodes – Storwize V7000 Model 2076-1xx/3xx Control Enclosure • Can use Volume mirroring to convert to a Compressed Volume Business Breakfast mit IBM ©2013 IBM Corporation 9 Real-time Compression – Basics • All copy services will interoperate with compressed Volumes Clients – All copy services will be working with uncompressed data Front End • No real changes in sizing and planning for FlashCopy or replication Remote Copy – Bandwidth sizing for replication same for compressed/non-compressed Volumes – Compression engine resources allocated per I/O group need considered in sizing Cache Flash Copy Mirroring Thin Provisioning Virtualization Random Access Compression Engine™ • All Thin Provisioning properties apply to compressed Volumes – Virtual capacity, real capacity, used capacity, etc. Back End • New property introduced Storage SVC S/W Component – Uncompressed capacity • Provides an indication of how much uncompressed data has been written RACE S/W Component ©2013 IBM Corporation 10 Business Breakfast mit IBM to the Volume What compression ratio will I achieve? • If you do not have a V7000 (new customer) – Then you can use the “Comprestimator” Tool if you use RHEL5, ESX5, Windows 2003+ or AIX 6.1+ hosts. 1.Download Comprestimator from IBM website 2.Upload Comprestimator to Server – e.g. “scp Comprestimator root@IP_of_ESXServer:/ 3.Change file to executable – “chmod +x Comprestimator” 4.Identify Volumes 5.Run Comprestimator Business Breakfast mit IBM ©2013 IBM Corporation 11 Storwize V7000 Advanced Functions • • • • • • Thin Provisioning – Included – Allows for storage optimization by consuming real capacity only when data is written FlashCopy – Included – Allows use of FlashCopy function with internal Storwize V7000 volumes as well as external storage under Storwize V7000 management – Up sell opportunity: FlashCopy Manager Easy Tier – Included – Allows for management of hotspots automatically by migrating extents from spinning drives to solid state drives as needed for higher performance – Up sell opportunity: TPC for Disk Midrange Edition Metro and/or Global Mirror – Optional – Allows you to replicate data synchronously or asynchronously between Storwize V7000 systems – Up sell opportunity: TPC for Replication Compression – Optional External Virtualization – Optional – Allows you to bring external fibre channel disk systems under Storwize V7000 control providing access to all the functions of the V7000 virtualization software ©2013 IBM Corporation 12 Business Breakfast mit IBM Storwize V3700 Leveraging the best of IBM storage technologies in an entry disk system Innovative GUI Space-efficient copies Easy Tier SAN Thin provisioning Space Efficient Data Protection Ease of Use Improves Productivity Business Breakfast mit IBM RAID Easy Tier Improves Response Time ©2013 IBM Corporation 13 Efficient Entry Storwize System  Enclosures contain up to twelve LFF (3.5”) or twenty-four SFF (2.5”) drives in just 2U  Control enclosure dual active-active controllers and drives   8GB Cache (4GB per controller) standard;  1Gb iSCSI host ports standard Expansion enclosure  Up to four expansion enclosures attach to one control enclosure  Up to 120 SFF or 60 LFF drives for up to 180TB raw capacity  Mix drive sizes and HDD/SSD in enclosure  Dual-active expansion canisters  RAID levels 0, 1, 5, 6, and 10  Redundant, hot-swappable components  Optional Software from Q2 2013: Easy Tier, Remote Mirroring, FlashCopy upgrade (2040 targets) Business Breakfast mit IBM ©2013 IBM Corporation 14 Storwize V3700: Graphical User Interface Business Breakfast mit IBM ©2013 IBM Corporation 15 Software & Features - Comparison Matrix Feature Storwize V3700 Storwize V7000 Internal Virtualisation Yes Migration only1 External Online Volume Migration Flex System V7000 SVC Yes Between Storage Pools Between I/O groups Yes Yes N/A Yes Thin Provisioning Yes Real Time Compression No Yes Easy Tier Future Yes Volume Copy – Virtual Disk Mirroring Yes Stretched cluster Host Access No FlashCopy3 Limit of 64 Remote Copy4 Future Layer Change5 No Yes Yes (sync. & async.) Yes Yes FCoE Yes iSCSI Yes Future Direct Attach No No Yes N/A Management plug-in Yes VAAI Yes SRM Microsoft Yes FCP SAS VMware Yes No Yes VSS Hardware Provider Yes SCOM Yes Business Breakfast mit IBM No Available natively with base license Available natively with additional 16 license ©2013 IBM Corporation Available with external tools Not Available Questions? Thank You Business Breakfast mit IBM ©2013 IBM Corporation 17