Transcript
Hardware Announcement June 22, 1999
IBM Netfinity ServeRAID-3HB Ultra2 SCSI Adapter — Advanced Performance and Functionality Overview The Netfinity ServeRAID -3HB Ultra2 SCSI Adapter lets you apply industry-leading performance and manageability to mission-critical enterprise storage applications. This second generation of the popular ServeRAID-3H adapter offers: • • •
Improved installation, configuration, and monitoring utilities Increased RAID and backup function support Enhanced setup and support for Microsoft Cluster Server
Powered to Perform and Scaled for Growth
The Netfinity ServeRAID-3HB Ultra2 SCSI Adapter is a high-technology, Low Voltage Differential SCSI (LVDS) PCI adapter for advanced-performance, mission-critical network server applications. Features include: • • • • • • •
Hot-swap, 64-bit PCI adapter Three channels — support up to 45 disk drives Wide Ultra2 SCSI — up to 80 MB/s data transfers and cable lengths up to 25 m 32 MB of mirrored battery-backup cache — improves overall performance RAID 5E boosts performance up to 20% in small RAID 5 configurations Adaptive caching — increases cache hits and reduces disk access time Significant performance tuning improvements — optimal performance out-of-the box
At Your Control
confidence. Additional enhancements to manageability and control include: •
• •
ServeRAID Manager — an easy-to-use Java -based utility for managing ServeRAID configurations across the enterprise FlashCopy — application for tape backup, software application test, or image rollout Elimination of the SCSI “heartbeat” cable — facilitates cluster installations
At a Glance The Netfinity ServeRAID-3HB Ultra2 SCSI Adapter delivers higher levels of performance, control, and manageability over current ServeRAID adapters. Features include: Industry-Leading Performance
• • •
LVDS Wide Ultra2 SCSI support 32 MB EDO cache memory Supports 64- or 32-bit PCI data paths Performance enhancements − RAID 5E and 1E support − 32 MB battery backup standard − Adaptive caching − Performance tuned out-of-the box
At Your Service
•
Netfinity ServeRAID-3HB Ultra2 SCSI Adapter and Netfinity servers are supported directly by the HelpCenter and through IBM-trained Business Partners. Help is always nearby and augmented by the following programs:
Control and Manageability
•
•
•
• •
ServeRAID ROM Update Program enabling simplified installation and automated maintenance of firmware Your existing Netfinity ServeRAID-3H and -3L adapters can be upgraded with these new firmware and utility updates through our Web site Remote Connect, MoST Connect, Update Connector, and Web support 1 Three-year, limited warranty 2
• • •
Logical Drive Migration interfacing with Netfinity Manager Auto Synchronization Hot-plug PCI support Latest enhancements − FlashCopy − ServeRAID Manager − ServeRAID ROM Update Program − Improved clustering installation
Footnotes: Refer to the Reference Information section for details.
Key Prerequisites A supported Netfinity or PC Server with two or more disk drives for data storage Planned Availability Date
The Netfinity ServeRAID-3HB Ultra2 SCSI Adapter contains the logical drive migration (LDM) and Auto Synchronization features that with administrative GUI utilities let you manage your disk array with
July 30, 1999
This announcement is provided for your information only. For additional information, contact your IBM representative, call 800-IBM-4YOU, or visit the IBM home page at: http://www.ibm.com. IBM United States
IBM is a registered trademark of International Business Machines Corporation.
199-152
Description The Netfinity ServeRAID-3HB Ultra2 SCSI Adapter is a second generation of the Netfinity ServeRAID-3H adapter. It offers significantly improved RAID performance, exceptional useability and control, plus the scalability you need to confidently build a reliable foundation for your networked business system.
New Features ┌─────────┬─────────────────────────┬───────────────────────────┐ │ Feature │ Description │ Benefit │ ├─────────┼─────────────────────────┼───────────────────────────┤ │ServeRAID│Java─based interface for │Provides better system │ │ Manager │all Netfinity ServeRAID │administration and reduced │ │ │products │TCO │ │ │ │ │ │ │Enterprise Monitoring ── │Provides best of breed user│ │ │central monitoring of all│interface for managing RAID│ │ │RAID configurations in │configurations │ │ │the network │ │ │ │ │Provides improved │ │ │Enhanced reporting of │serviceability │ │ │code revision levels │ │ │ │ │Runs native in │ │ │Identifies disk drives │Windows NT(R) and UnixWare │ │ │by flashing LEDs on │ │ ├─────────┼─────────────────────────┼───────────────────────────┤ │RAID 5E │Hot─spare drive │Puts hot─spare to work to │ │ │distributes data across │improve performance │ │ │all drives instead of │ │ │ │leaving drives dormant │Provides up to 20% │ │ │ │performance boost in small │ │ │IBM exclusivity │RAID 5 configurations │ │ │ │ │ ├─────────┼─────────────────────────┼───────────────────────────┤ │RAID 1E │Mirroring of an │Allows more efficient │ │ │odd number of disk drives│utilization of disk drives │ │ │ │ │ │ │ │Improves performance due to│ │ │ │additional spindles │ ├─────────┼─────────────────────────┼───────────────────────────┤ │FlashCopy│Backup Option ── provides│Allows system administrator│ │ │copy of logical volume │to make large non─ │ │ │can be backed to tape │disruptive backups to tape │ │ │ │while user applications are│ │ │Snapshot option── creates│running │ │ │copy of a logical volume │ │ │ │that can be modified │Lets system administrator │ │ │while maintaining the │test software enhancements │ │ │integrity of the original│and upgrades then revert │ │ │copy │back to the previous │ │ │ │version in the event a │ │ │ │problem occurs │ ├─────────┼─────────────────────────┼───────────────────────────┤ │Perfor─ │Multiple performance │Provides significantly │ │ mance │enhancements │improved out─of─the box │ │ Tuning │ │performance │ │ │ │ │ │ │ │Reduces installation │ │ │ │complexity ── tuning │ │ │ │intervention unnecessary │ ├─────────┼─────────────────────────┼───────────────────────────┤ │Adaptive │Firmware that dynamically│Provides major performance │ │Caching │adjusts to access │boost as data is more often│ │ │patterns in data reads │available to the CPU │ │ │and predictively reads │without read/write delays │ │ │data into cache │ │ │ │ │ │ │ │Increased cache hits and │ │ │ │reduced disk access time │ │ │ │ │ │ │ │Disk overhead minimized │ │ │ │as firmware combines many│ │ │ │small writes into larger │ │ │ │disk writes │ │ └─────────┴─────────────────────────┴───────────────────────────┘
┌─────────┬─────────────────────────┬───────────────────────────┐ │ Feature │ Description │ Benefit │ ├─────────┼─────────────────────────┼───────────────────────────┤ │32 MB │32 MB mirrored cache ── │Protects data and config─ │ │Battery │allows fast write─back │uration information in the │ │Backup │cache method to be │event of adapter failure │ │ │enabled right from the │ │ │ │factory │Provides performance │ │ │ │improvements │ │ │ │ │ │ │ │Provides │ │ │ │performance improvement in │ │ │ │ServerGuide installations │ │ │ │ │ │ │ │Eliminates need to order │ │ │ │and install option │ ├─────────┼─────────────────────────┼───────────────────────────┤ │ServeRAID│GUI interface that allows│Simplifies installations │ │ROM │ROM (firmware) to be at │ │ │Update │the latest levels │Automated maintenance │ │Program │ │ │ ├─────────┼─────────────────────────┼───────────────────────────┤ │Elimina─ │Improved architecture │Simplifies cluster setup │ │tion of │that eliminates need for │and requires fewer cables │ │SCSI │MSCS configurations with │ │ │Heartbeat│shared ServeRAID disk │Provides ability to attach │ │Connec─ │disk arrays to use a SCSI│internal or external disks │ │tion │Heartbeat Connection │to the first ServeRAID │ │ │ │channel │ └─────────┴─────────────────────────┴───────────────────────────┘
Investment Protection Owners of the Netfinity ServeRAID-3H and -3L Ultra2 SCSI Adapters can obtain the following new features incorporated into Netfinity ServeRAID-3HB Ultra2 SCSI Adapter from the Web without charge: • • • • • • •
RAID 5E Performance tuning improvements FlashCopy ServeRAID Manager Elimination of heartbeat cable for ServeRAID-3H ServeRAID ROM Update Program Adaptive Caching
Effective today, these updates can be downloaded from our Web site at: http://www.pc.ibm.com/support
Legacy Features The Netfinity ServeRAID-3HB Ultra2 SCSI Adapter delivers excellent performance and scalability to database and application server environments found in enterprise network computing. Features include: •
Full-length, three-channel PCI RAID adapter supporting up to 45 hard disk drives with RAID levels 0, 1, and 5
•
32 MB of cache
•
Support for both SCSI-2 (20 MB/sec), Wide Ultra SCSI modes (40 MB/sec), and Ultra2 (80 MB/sec)
•
Data transfer capability of up to 264 MB/second over the PCI bus when installed in servers supporting 64-bit PCI slots such as the Netfinity 7000 M10
•
Contains two industry standard .8-mm VHDCI connectors for attachment of external SCSI enclosures such as Netfinity EXP storage expansion units. By using the Third Channel Cable included with the adapter, the third channel can support an additional data storage unit if not used for internal drive support.
Excellent useability features are provided by the Netfinity ServeRAID-3HB Ultra2 SCSI Adapter for setting up, monitoring, and modifying the disk array. Logical Drive Migration (LDM) is an industry-leading function included
199-152
-2-
with IBM ServeRAID adapters that allows various complex RAID setup and maintenance operations to be administered in a simple straight-forward manner. These functions include: •
•
The Netfinity ServeRAID-3HB Ultra2 SCSI Adapter will replace the current Netfinity ServeRAID-3H adapter.
Changing from RAID level 0 to RAID level 5, or vice versa, without requiring the data to be restored from a backup source
Reference Information
Expanding the array by adding up to three physical drives at a time − −
•
Product Transition
1 2
Logical drive size can be increased or left unchanged If left unchanged, additional logical drives can be defined
For information on IBM′s Statement of Limited Warranty, call 800-772-2227 or contact your IBM representative or reseller. Copies are available upon request.
Changing the RAID level on-the-fly from RAID 0 to RAID 5 by adding a drive, or RAID 5 to RAID 0 by removing a drive
•
Changing a two disk drive RAID 1 to RAID 5, on-the-fly, by adding one physical drive
•
Concurrent I/O support allowing logical drives to be accessed by users during LDM
•
Degraded mode support allowing a logical drive in critical mode not to affect LDM if already in progress, or preventing LDM start if the drive is in critical mode prior to start of LDM
•
Power failure recovery allowing LDM activity recovery even after a power disruption
•
Hot-Swap Rebuild — automatically starts rebuilding a replaced disk drive without operator intervention
•
Data scrubbing — periodically scans disk services and automatically repairs bad sectors on the disk array to enhance data integrity
•
One-step array initialization and synchronization — reduces the time to prepare a new RAID 5 array to accept data
•
Auto synchronization — automatically initializes drives without user intervention
•
Supporting popular network operating systems, such as Windows NT, OS/2 , NetWare, and SCO
Some programs may not be available in all countries. Limited warranty includes Warranty Service in those countries where this product is sold by IBM or IBM Business Partners (registration required).
Trademarks ServeRAID and Netfinity Manager are trademarks of International Business Machines Corporation in the United States or other countries or both. Netfinity, HelpCenter, and OS/2 are registered trademarks of International Business Machines Corporation in the United States or other countries or both. Microsoft is a trademark of Microsoft Corporation. Windows NT is a registered trademark of Microsoft Corporation. Java is a trademark of Sun Microsystems, Inc. Other company, product, and service names may be trademarks or service marks of others.
Year 2000 This product does not have date dependencies and is therefore Year 2000 Ready.
Product Positioning Due to its superior performance and functionality, the Netfinity ServeRAID-3HB Ultra2 SCSI Adapter is positioned above the current Netfinity ServeRAID-3H and -3L Ultra2 SCSI Adapters. This new adapter provides the highest performance RAID functions and distances for SCSI application environments. While Netfinity Fibre Channel products are positioned above Netfinity ServeRAID-3HB Ultra2 SCSI Adapter due to greater performance, distance, and scalability, they are significantly more expensive to purchase and install. The Netfinity ServeRAID-3HB Ultra2 SCSI Adapter is designed for an advanced, mission-critical, enterprise application where performance and massive data storage capability are a must.
-3-
199-152
IBM US Announcement Supplemental Information June 22, 1999
Netfinity ServeRAID -3HB Ultra2 SCSI Adapter (37L6086) Technical Information Physical Specifications
• • • • • •
Full-length PCI adapter card Two VHDCI .8-mm external connectors One internal, industry standard, 68-pin connector Three RAID channels Supports Ultra2 SCSI modes of 80 MB/sec, Wide Ultra SCSI modes of 40 MB/sec, and SCSI-2 Fast/Wide modes of 20 MB/sec SPCI connector for 32 MB Battery-Backup Cache
Operating Environment
•
Temperature: − −
•
10° to 35°C (50° to 95°F) at 0 to 914 m (0 to 3,000 ft) 10° to 32°C (50° to 90°F) at 914 to 2,133 m (3,000 to 7,000 ft)
Relative humidity: 8% to 80%
Agency Approvals
• • • • • •
Verified to comply with Part 15 of the FCC Rules for a Class A digital device CE Mark (EN 55022 Class A) CISPR 22, Class A IEC VCCI-A C-Tick (AS/NZS 3548:1995)
ENERGY STAR-Compliant: No Note: The ENERGY STAR emblem does not represent EPA endorsement of any product or service.
Hardware Requirements: The Netfinity ServeRAID-3HB Ultra2 SCSI Adapter is supported in the following servers: Description
Machine Type
PC Server 325
8639
PC Server 330 Netfinity 3000 Netfinity 3500 Netfinity 5000 Netfinity 5500 Netfinity 5500 M10 Netfinity 5500 M20 Netfinity 7000 Netfinity 7000 M10
8640 8476 8644 8659 8660 8661 8661 8651 8680
1 2
Models
-EJ0, -ES0, -ESV, -RS0 -PT0, -PTW, -PB0, -RB0 All 1 All 2 All All All All All All
Requires an Internal DASD Status Cable (76H5399) for internal RAID configurations using hot-swap bays. Supports a single Netfinity ServeRAID-3HB Ultra2 SCSI adapter. Must be installed in slot number 3.
Software Requirements: The Netfinity ServeRAID-3HB Ultra2 SCSI Adapter supports the following network operating systems:
• • • • • •
OS/2 Warp Server Advanced, V4.0 SMP Feature IntranetWare 1.0 NetWare 4.2 Microsoft Windows NT 4.0 Server SCO Open Server 5.0.4 SCO Unixware 7.0
Compatibility: Netfinity ServeRAID-3HB Ultra2 SCSI Adapter is compatible with the following devices: Description
Part Number
Hard Disk Drives (HDDs)
Netfinity 9.1 GB 10K-3 Wide Ultra SCSI Hot-Swap SL HDD Netfinity 18.2 GB 10K-3 Wide Ultra SCSI Hot-Swap SL HDD Netfinity 36.4 GB 10K-3 Wide Ultra SCSI Hot-Swap SL HDD Netfinity EXP 9.1 GB 10K-3 Wide Ultra SCSI Hot-Swap SL HDD Netfinity EXP 18.2 GB 10K-3 Wide Ultra SCSI Hot-Swap SL HDD Netfinity EXP 36.4 GB 10K-3 Wide Ultra SCSI Hot-Swap HDD Netfinity 9.1 GB 10K-3 Wide Ultra2 SCSI Hot-Swap SL HDD Netfinity 18.2 GB 10K-3 Wide Ultra2 SCSI Hot-Swap SL HDD Netfinity 36.4 GB 10K-3 Wide Ultra2 SCSI Hot-Swap HDD Netfinity 9.1 GB Wide Ultra2 SCSI Hot-Swap SL HDD Netfinity 18.2 GB Wide Ultra2 SCSI Hot-Swap SL HDD Netfinity 36.4 GB Wide Ultra2 SCSI Hot-Swap HDD Netfinity 9.1 GB 10K Wide Ultra SCSI SCA-2 SL HDD Netfinity EXP10 9.1 GB 10K Wide Ultra SCSI SCA-2 SL HDD Netfinity 18.2 GB 10K Wide Ultra SCSI SCA-2 SL HDD Netfinity EXP10 18.1 GB 10K Wide Ultra SCSI SCA-2 SL HDD Netfinity 4.51 GB 10K Wide Ultra SCSI SCA-2 HDD Netfinity 9.1 GB 10K Wide Ultra SCSI SCA-2 HDD Netfinity EXP10 9.1 GB 10K Wide Ultra SCSI SCA-2 HDD Netfinity 9.1 GB Wide Ultra SCSI SCA-2 SL HDD IBM 9.1 GB Wide Ultra SCSI SL Hot-Swap HDD
36L9806 36L9807 36L9808 36L9809 36L9810 36L9811 36L9748 36L9749 36L9750 36L9744 36L9745 36L9746 01K8054 01K8499 01K8503 01K8500 01K8009 01K8010 01K7968 01K8053 02K0477
This announcement is provided for your information only. For additional information, contact your IBM representative, call 800-IBM-4YOU, or visit the IBM home page at: http://www.ibm.com. IBM United States
IBM is a registered trademark of International Business Machines Corporation.
199-152
Installation Time: Approximately one hour
Part Number
Description
Packaging: One box per option
Netfinity 18.2 GB Wide Ultra SCSI SCA-2 HDD Netfinity 18.2 GB Wide Ultra SCSI Hot-Swap SL HDD Netfinity 36.4 GB Wide Ultra SCSI Hot-Swap HDD Netfinity EXP10 18.2 GB Wide Ultra SCSI SCA-2 HDD Netfinity EXP 36.4 GB Wide Ultra SCSI Hot-Swap HDD Netfinity EXP10 4.51GB 10K Wide Ultra SCSI SCA-2 HDD PC Server 704 2.14GB Wide Ultra SCSI Hot-Swap HDD PC Server 704 4.51GB Wide Ultra SCSI Hot-Swap HDD PC Server 704 9.1GB Wide Ultra SCSI Hot-Swap HDD PC Server 4.51GB Wide Ultra SCSI Hot-Swap HDD PC Server 9.1GB Wide Ultra SCSI Hot-Swap HDD PC Server 4.51GB F/W SCSI-2 Hot-Swap SL HDD PC Server 9.1GB F/W SCSI-2 Hot-Swap SL HDD IBM 18.2 GB Wide Ultra SCSI Hot-Swap HDD IBM 18.2 GB Wide Ultra SCSI Hot-Swap SL HDD
01K8055 Shipment Group: Adapter
02K0440
• • • •
02K0441 01K8501
ServeRAID adapter card with 32 MB battery backup Third Channel Cable assembly RAID utilities and driver CD-ROM Installation instructions
02K0442
Security, Auditability, and Control 01K7960 94G7519
These products use the security and auditability features of the Netfinity or PC Server in which they are installed.
94G7098
Terms and Conditions
94G7099
Field-Installable Customer Setup Warranty Period Service Type Maintenance Agreement Optional Upgrade Central Facility Maintenance Service (CFMS) Option Licensed Programs
94G7491 94G7492 36L9802 36L9803 02K0478
Yes Yes 3 Years CCE No No No Yes
Note: IBM programs are licensed under the terms and conditions of the IBM License Agreements that ship with the product. Non-IBM programs are available from IBM as distributed by the program supplier.
02K0439
Storage Units
Help and Service Information
Netfinity EXP10 Netfinity EXP15 PC Server 3519 Rack Storage Expansion Enclosure PC Server 3518 Enterprise Expansion Tower
35201RU 35202RU 3519R01
During the warranty period, call 800-772-2227 for technical support 24 hours a day, 7 days a week, to answer any questions regarding your new IBM option. Response time will vary depending on the number and nature of calls received. If you need warranty service, return or exchange is available. Additionally, if your IBM option is installed in an IBM computer, you may be entitled to service at your location. Your technical support representative can help you determine the best alternative.
3518001
Cables
IBM 1 M External .8-mm SCSI Cable IBM 2 M External .8-mm SCSI Cable IBM 3 M External .8-mm SCSI Cable IBM 4.3 M External .8-mm SCSI Cable IBM Third Channel Cable IBM DASD Status Cable IBM .8-mm to 68-pin SCSI Adapter Netfinity EXP10 3 M External Auto-Sensing Cable Netfinity 2 M Ultra2 SCSI Cable Netfinity 4.2 M Ultra2 SCSI Cable Netfinity 12 M Ultra2 SCSI Cable
76H3589 01K8027 01K8028 01K8029 76H5400 76H5399 01K8017 03K9352
Charges Description ServeRAID-3HB Ultra SCSI Adapter
03K9310 03K9311 03K9312
3
Limitations
Part Number
ERP3
37L6086
$1,899
Estimated reseller price to end user. Actual reseller price may vary.
Trademarks
•
Splitting a SCSI RAID channel between external and internal devices is not supported with the Netfinity ServeRAID-3HB Ultra2 SCSI Adapter.
•
The Netfinity 3000 can support a single Netfinity ServeRAID-3HB Ultra2 SCSI Adapter. The RAID adapter must be installed in PCI slot number 3.
ServeRAID is a trademark of International Business Machines Corporation in the United States or other countries or both. Netfinity and OS/2 are registered trademarks of International Business Machines Corporation in the United States or other countries or both. Microsoft is a trademark of Microsoft Corporation. Windows NT is a registered trademark of Microsoft Corporation. Other company, product, and service names may be trademarks or service marks of others.
Planning Information Cable Orders Required: External cables are required when attaching external SCSI storage enclosures. Refer to this announcement for supported SCSI cables.
199-152
Netfinity ServeRAID-3HB Ultra2 SCSI
-2-