Preview only show first 10 pages with watermark. For full document please download

Ibm Storage News - Neues Aus Der Storwize Familie

   EMBED


Share

Transcript

IBM Storage News Neues aus der Storwize Familie Manuel Schweiger Master Certified IT Specialist © 2014 IBM Corporation Meet The Storwize Family A comprehensive range of fully virtualized storage systems! !  !  !  !  One code base on all platforms! One set of functions (selectively licensed)! One user interface! One CLI! SAN Volume Controller Flex System V7000 Storwize V7000 Unified Storwize V7000 GEN2 Storwize V5000 Storwize V3700 © 2014 IBM Corporation SVC Supported Environments (sample view*) – applies to Storwize IBM z/VSE z/VM z/Linux Novell NetWare VMware vSphere OES2 Microsoft Windows Hyper-V HP-UX 11i IBM Power Tru64 IBM AIX Solaris OpenVMS IBM I iSCSI or FCOE Point-in-time Copy 1Gb or 10Gb Full volume, Copy on write 256 targets, Incremental, Cascaded, Reverse, Snapshots, FlashCopy Mgr Thin Provisioning Compellent Fluid Data IBM DS Easy Tier IBM XIV DS3000, DS4000 DS5000, DS6000 DS8000 Violin Hitachi N series Lightning Thunder FlashSystem Storwize Family TagmaStore AMS, WMS, USP, USP-V VSP MA, EMA MSA, EVA, XP, P9500, 3Par EMC IBM TS7650G IBM BladeCenter Flex System PureFlex Continuous Copy Multiple Cluster Mirror Metro/Global Mirror Stretched Cluster Real-time Compression HP Citrix Xen Server Apple ProtecTIER Mac OSGateway SGI IRIX 8Gbps SAN fabric Virtual Disk Mirroring IBM Linux (Intel/Power/z) RHEL 4/5/6 SUSE 9/10/11 Sun CLARiiON StorageTek CX4, StorEdge Symmetrix, DMX, VMAX, VNX, VNXe 1024 Hosts SAN Internal SSD NetApp NEC Fujitsu TMS Eternus RamSAN XioTech Bull NexSAN Pillar FAS Emprise iStorage Storeway SATABeast Axiom * Confirm all supported configurations at ibm.com/storage/support/2145 and click on Support 3 © 2014 IBM Corporation What have we announced? "  New SVC engine "  New Storwize V7000 – Including new 600GB 15K RPM HDD "  Statements of Direction "  Storwize Family Software V7.3 – Easy Tier 3 – Storage Pool Balancing – Simplified licensing "  Storwize V7000 Unified File Module Software V1.5 – NFS v4, SMB2.1 – Multi-tenancy – ACE multi-writer – Automated ID mapping "  Increased expansion for Storwize V3700 and Storwize V5000 4 © 2014 IBM Corporation SVC DH8 – Front View Boot drives 2 – 300GB 10K SAS 5 System indicators Battery 1 Battery 2 © 2014 IBM Corporation SVC DH8 – Internal View PCIe Riser cards PSUs DIMMs CPU Fans Boot drives Batteries 6 © 2014 IBM Corporation SVC DH8 – Hardware Overview " 8-core CPU with 32GB memory for SVC "  Minimum 1 HIC for I/O "  Can add a 2nd I/O HIC, and SAS HIC on this CPU "  2nd CPU is optional "  "  "  "  7 Comes with extra 32GB memory Required to access 3rd I/O HIC Required for RTC At least 1 Compression Accelerator card required for RTC system battery CPU1 Boot / dump drives QPI CPU2 SVC RTC PCIe Gen3 PCIe Gen3 © 2014 IBM Corporation SVC DH8 – Rear View PCIe expansion slots Mgmt ports Slot 1 Slot 2 Slot 3 1 Gb iSCSI ports 8 750W PSUs Slot 4 Slot 5 Slot 6 Technician Port © 2014 IBM Corporation More I/O ports "  Prior to v7.2, we only supported 6 FC ports for backend storage virtualisation "  In 7.2.0, we extended the max local port count for backend storage virtualisation to 8 – 2nd 4 port HBA or FCoE (2 port 10Gb card) "  Because we support up to 3 I/O cards in the SVC DH8, the maximum local I/O port count for backend storage virtualisation is extended to 12 – maximum local I/O ports is also 12 on SVC DH8 "  Check backend controller spec for how many initiator ports from one host a storage controller can handle – Some of the older controller may have a limit for this. •  Use zoning to limit the initiator ports according to the limit of the backend controller – Should be able to set up a host group or multiple hosts in the backend controller to work around this 9 © 2014 IBM Corporation 10Gb Ethernet Card (FCoE and iSCSI) " The new 4x port 10GbE card will only be supported in the new SVC DH8 and in the Storwize V7000 2076 -524 " The card is delivered with the SFPs fitted, unless it is a FRU. " In SVC 7.3.0 we will only support 1 x 10GbE adapter in each of the platforms (see above) " Only IBM supported 10Gb SFPs should be used " Each adapter port has amber and green coloured LED to indicate port status – fault LED is not used in 7.3.0. 10 Green LED Meaning On Link established Off No link © 2014 IBM Corporation Compression accelerator adapter "  Up to a total of 2 compression accelerator adapters can be installed, each additional adapter installed will improve I/O performance when using compressed volumes –  Intel QuickAssist technology is used. IBM is the first in the industry to integrate this technology into our products •  second generation Intel Communications Chipset 89xx Series (Coleto Creek) nd –  2 CPU and extra 32 GB of memory are mandatory with the compression accelerator adapter "  The use of compression accelerator adapters is mandatory (at least one) if users wish to use compression on SVC DH8. –  For an I/O group containing a SVC DH8 with no compression accelerator, an attempt to create first compressed volume will fail. –  The addnode command will also fail, if trying to add a SVC DH8 without a compression accelerator, to an I/O group which has compressed volumes 11 © 2014 IBM Corporation SVC DH8 – Expansion Enclosure 2145 24F "  With Release 1 and 7.30 Code – support 2 expansion enclosures per I/O Group "  Ports 1 and 3 of the 12 Gb SAS card can be used to attach 2U24 Expansion enclosures of flash drives "  Expansion enclosures are physically identical to the V7000 Gen2 expansion enclosures, but will have a different product ID – SVC DH8 cannot use the V7000 Gen2 expansion enclosures, V7000 Gen2 cannot use the SVC DH8 expansion enclosure 12 © 2014 IBM Corporation SVC CG8 vs DH8 13 Attribute (per node) SVC CG8 SVC DH8 R1 CPU 2X 6 cores Westmere 2x 8- cores Ivy Bridge Controller memory 24GB to 48GB 32GB to 64GB Host I/O 2x 1GbE 4x to 8x - 8Gb FC 2x 10GbE (2 card max) 3x 1GbE 0 to 12x - 8Gb FC 0 to 4x – 10GbE (3 I/O card max) Compression resources 8 cores (with 2nd CPU fitted) 8 cores (with 2nd CPU fitted) 1 or 2 Compression Accelerator Card Drive expansion 4 flash drive local to node (RAID 0,1,10 only) 48 flash drives shared by 2 nodes (RAID 0,1,5,6,10) SAS fabric 6Gb SAS 12Gb SAS © 2014 IBM Corporation SVC Investment Protection " New SVC engines may be added to existing SVC systems without disruption " New SVC engines may replace existing engines in SVC systems without disruption " All engines in an SVC system may access flash expansion capacity " SVC system must be running Version 7.3 software 14 © 2014 IBM Corporation Storwize V7000 Hardware Refresh: 2076-524 Control Enclosure "  Control enclosure is 2U, same physical size as previous model "  Front view looks identical to V5000 and only comes in 24 drive SFF configuration for the control enclosure and both SFF and LFF configurations for expansion enclosures "  Back layout is very different to make room for the more powerful canisters PSU 1 15 Canister 1 Canister 2 PSU 2 © 2014 IBM Corporation New Storwize V7000 Control Enclosure "  Available only in 2.5-inch drive model – 2076-524 Slot Supported cards 1 "  Three expansion slots numbered 1-3 left to right when viewed from the rear Compression pass-through Compression Acceleration card 2 None, 8Gb FC*, 10GbE** 3 None, 8Gb FC*, 10GbE** "  Ports on a card are numbered top to bottom starting with 1 "  Supported expansion cards – 4x 8Gb FC – 4x 10GbE iSCSI / FCoE – Compression pass-through comes standard with system to enable on-board compression engine – Compression Acceleration card "  Technician IP port replaces USB key configuration "  Same funcionality as on SVC DH8 * Statement of Direction for 16Gb FC announced ** Only one 10GbE card supported per node canister 4x 1GbE ports SAS expansion ports Compression Host interface slots accelerator slot PSU Technician IP port PSU Dual controller canisters 16 © 2014 IBM Corporation Storwize V7000 Hardware Refresh: 2076-24/12F Expansion Enclosure "  Available in 2.5- and 3.5-inch drive models –  2076 Models 24F and 12F respectively "  Attach to new control enclosure using 12Gbps SAS "  Mix drive classes within enclosure including different drive SAS interface speeds "  Mix new enclosure models in a system even on same SAS chain "  All drives dual ported and hot swappable 2.5-inch Flash Drives 200GB, 400GB, 800GB Flash 12Gbps 2.5-inch High Performance Drives 300GB, 600GB SAS, 15K RPM 12Gbps 600GB, 900GB, 1.2TB SAS, 10K RPM 6Gbps 1TB NL-SAS, 7.2K RPM 6Gbps 3.5-inch High Capacity Drives 2TB, 3TB, 4TB 17 NL-SAS, 7.2K RPM 6Gbps © 2014 IBM Corporation Storwize V7000 Hardware Refresh: Expansion Enclosure Cabling 18 © 2014 IBM Corporation Storwize V7000 Hardware Refresh: SAS Chain Layout "  Each control enclosure supports two expansion chains and each can connect up to 10 enclosures – Max. 1056 drives allowed ‘SAS port 0’ Chain 0 "  SSDs can also go in other enclosures if more then 24 required for capacity reasons "  HDDs can go in control enclosure if desired – Mix of SSDs and HDDs is fine too 19 Internal SAS links SAS Adapter Control "  Internal double-width high-speed link to the control enclosure –  SSDs should be installed in control enclosure –  Same SAS bandwidth in control enclosure dedicated to these 24 slots as there is to other two chains combined Node Canister SAS port 1 Chain 1 SAS port 2 Chain 2 Expansion Expansion Expansion Expansion 8 more 8 more © 2014 IBM Corporation V7000 Gen 1 vs. Gen 2 Storwize V7000 GEN1 V7000 GEN2 CPU Intel Jasper Forest 4-core Intel Ivy Bridge 8-core Controller memory (per node) 8GB 16GB-64GB configurable Host I/O (per node) 2x 1GbE 4x 8Gb FC 2x 10GbE (some models) 3x 1GbE Mix of: 4 or 8 ports 8GGb FC 4 or 8 ports 10GbE Compression resources (per node) 3 CPU cores On-board Compression Assist Engine Optional second Compression Assist Engine Drive expansion Up to 9 expansions (240 drives per controller) Up to 20 expansions (504 drives per controller) Drive fabric 6Gb SAS 12Gb SAS 20 © 2014 IBM Corporation New Storwize V7000 Migration and Investment Protection "  Build Storwize V7000 Unified systems using new Storwize V7000 and Storwize V7000 File Modules (2073-720) – Requires File Module software V1.5 "  Can mix new and existing Storwize V7000 systems in a cluster "  Provides complete protection for existing Storwize V7000 investments – All existing and new storage can be accessed by all systems "  Migration from existing system with no downtime at all – For systems that support nondisruptive volume move – No competitive system can make similar claim "  SVC and new Storwize V7000 can virtualize existing Storwize V7000 or any other installed disk system – Provides conventional Storwize family migration using virtualization Cluster Existing V7000 21 New V7000 System Existing Virtualize Existing Replicate V7000 V7000 © 2014 IBM Corporation Easy Tier Evolution "  Easy Tier 1 (DS8700 R5.1 and Storwize Family) –  Automated cross-tier performance management for SSD/HDD hybrid pools –  Manual mode management support for dynamic extent pool merge and dynamic volume relocation "  Easy Tier 2 (DS8700/DS8800 R6.1) –  Automated cross-tier performance or storage economics management for hybrid pools with any 2 tiers (SSD/ENT, SSD/NL or ENT/NL) –  Automated intra-tier performance management (auto-rebalance) in hybrid pools –  Manual mode management support for rank depopulation and optimized volume restriping within nonmanaged pools (manual volume rebalance) "  Easy Tier 3 (DS8700/DS8800 R6.2 and Storwize Family 7.3) –  Automated cross-tier performance and storage economics management for hybrid pools with 3 tiers (SSD/ENT/NL) –  Automated intra-tier performance management in both hybrid (multi-tier) as well as homogenous (single tier) pools (auto-rebalance) –  Thin Provisioning support for Extent Space Efficient (ESE) Volumes "  Easy Tier 4 (DS8800 R6.3 / DS8870 R7.0) –  Support for encryption capable environments •  DS8800 and DS8870 have FDE capable SSD and nearline drives "  Easy Tier 5 (DS8870 R7.1) 22 –  Server –  Application –  Heat map transfer © 2014 IBM Corporation Easy Tier 3 " Now supports two or three tiers – Flash + 2 disk tiers – Flash + 1 disk tier – 2 disk tiers " Deploy flash and enterprise disk for performance Flash Arrays Less Active Data Migrates Down Active Data Migrates Up " Grow capacity with low cost disk " Storwize V7000 moves data automatically between tiers HDD Arrays " Available on all systems licensed for Easy Tier – No additional charge 23 © 2014 IBM Corporation Possible Hotspot creation with Software Release 7.2 and older Workload "  Extents are distributed based on free capacity on mdisks. vdisk Extent distribution SVC mdiskgrp mdisk0 mdisk1 mdisk2 mdisk3 LUN0 LUN1 LUN2 LUN3 Storage Subsystem 300GB 7+P 300GB 7+P 24 600GB 7+P 600GB 7+P 200 IOPS / Extent 100 IOPS / Extent © 2014 IBM Corporation EasyTier 3 - Storage Pool Balancing (new feature in 7.3) Workload "  Extents are distributed based on workload / performance vdisk Extent distribution SVC mdiskgrp mdisk0 mdisk1 mdisk2 mdisk3 LUN0 LUN1 LUN2 LUN3 Storage Subsystem 300GB 7+P 300GB 7+P 25 600GB 7+P 600GB 7+P 200 IOPS / Extent 100 IOPS / Extent © 2014 IBM Corporation Automated Storage Pool Balancing in Action "  Configuration Drive MDisk Volume Comments 24 - 300GB 15K RPM Drives 3 - RAID-5 arrays Vol_0, Vol_1, Vol_2, Vol_3 each 32GB capacity Total MDisk size 5.44TB Total Volume size 128GB All Volumes are created on MDisk0 initially "  Performance improved by balancing workload across all 3 MDisks: Improvement Throughput 6000 vs 12.000 IOps Latency: 45 vs 20 msec "  Automated Storage Pool Balancing is included in the Base Licensing. No additional EasyTier license required to use it. "  Enabled by default 26 © 2014 IBM Corporation Using the STAT Tool " Download the heatfile " Run the STAT Tool " Click on index.html 28 © 2014 IBM Corporation Workload skew drives Easy Tier benefits 100 90 50% of the extents do 10% of the MB and virtually no random IOPS! 80 Percent of workload 70 60 50 40 58% of the random IOPS and 33% of the MB from about 5% of the extents! 30 20 10 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 Percent of extents Percent of small Ios Percent of MB © 2014 IBM Corporation Why re-architect Cache? "  More scalable for the future –  Required for supporting beyond 8K volumes –  Required for support beyond 8 node clusters –  Required for 64 bit user addressing beyond 28 GB •  SVC code only uses 28 GB max today "  Required for larger memory sizes in nodes/canisters "  Required for more CPU cores "  Reduces # of IOPs copy services do directly to the back end storage "  Required for flush-less FlashCopy prepare –  Allows near CDP like capability "  RtC benefits from the cache underneath "  Algorithmic independence –  Allows changes to pre-fetch and destage algorithms without touching the rest of the cache "  Improved debugging capability 34 © 2014 IBM Corporation Cache Architecture pre-V7.3.x FWL = Forwarding Layer Host I/O FWL Front End TP/RtC FWL Remote Copy Cache Volume Mirror FWL Virtualization FWL RAID 1/5/6/10 Backend TP/RtC Virtualization RAID 1/5/6/10 Backend FlashCopy 35 © 2014 IBM Corporation Cache Architecture V7.3.x FWL = Forwarding Layer Host I/O FWL Front End TP/RtC FWL Remote Copy Upper Cache Volume Mirror FWL Lower Cache Lower Cache Virtualization Virtualization FWL RAID 1/5/6/10 FlashCopy 36 TP/RtC Backend RAID 1/5/6/10 Backend © 2014 IBM Corporation New SVC Data Engine Power to Virtualize " Virtualized server environments demand virtualized storage " 2x performance: up to 128 cores " 50% more connectivity: up to 96 FC ports " 2.5x cache: up to 512GB " 6x integrated flash: up to 192 drives 39 © 2014 IBM Corporation SVC Maximum Performance (One I/O Group) Uncompressed SVC CG8 New SVC DH8 Read Hit IOPS 1,000,000 1,500,000 Read Miss IOPS 360,000 630,000 Write Miss IOPS 125,000 200,000 “DB-like” 200,000 385,000 SVC CG8 New SVC DH8 Read Miss IOPS 2,600-50,000 71,000-175,000 Write Miss IOPS 1,200-16,000 28,000-115,000 “DB-like” 2,200-40,000 59,000-149,000 Compressed " Compressed performance shows a range depending on I/O distribution " Compressed performance is better than uncompressed in some cases because of fewer I/Os to drives and additional cache benefits Preliminary data: Subject to change before GA © 2014 IBM Corporation New Storwize V7000 Power and Scalability for All Your Data " 2x scalability: up to 4PB " 2x performance: up to 64 cores " 2x infrastructure speed: 12Gbps SAS " 2x connectivity: up to 64 FC ports " 8x cache: up to 512GB 41 © 2014 IBM Corporation Storwize V7000 Maximum Performance (One Control Enclosure) Uncompressed Previous Storwize V7000 New Storwize V7000 Read Hit IOPS 850,000 1,300,000 Read Miss IOPS 125,000 238,000 Write Miss IOPS 25,000 50,000 “DB-like” 52,000 100,000 Previous Storwize V7000 New Storwize V7000 Read Miss IOPS 2,000-44,000 39,000-149,000 Write Miss IOPS 1,100-17,000 22,500-78,000 “DB-like” 1,500-32,700 41,000-115,000 Compressed " Compressed performance shows a range depending on I/O distribution " Compressed performance is better than uncompressed in some cases because of fewer I/Os to drives and additional cache benefits Preliminary data: Subject to change before GA © 2014 IBM Corporation New Simplified Storwize Licensing Structure for V5000 & V7000 License Per Enclosure Option 1 FLEXIBLE OPTIONS Controller Expansion External $  Base Advanced Functions #  Easy Tier #  Flashcopy #  Remote Mirror #  Compression* Option 2 FULL BUNDLE Controller Expansion External $  Base $  Full Bundle $  Easy Tier $  Flashcopy $  Remote Mirror $  Compression* Summary 44 •  Licenses: Controller, Expansion, External Data Virtualization •  Advanced Functions are identically priced for Controller, Expansion & External •  Advanced function licenses, when selected, are required for all enclosures •  No capping •  No complexity * Storwize V7000 Only © 2014 IBM Corporation Statements of Direction "  IBM intends to enhance the new SVC engine and new Storwize V7000 to support 16 Gb Fibre Channel connectivity "  The cache upgrade feature on the new Storwize V7000 provides performance benefit only when Real-time Compression is used. IBM intends to enhance IBM Storwize Family Software for Storwize V7000 to extend support of this feature to also benefit uncompressed workloads. "  The second CPU with 32 GB memory feature on SVC Storage Engine Model DH8 provides performance benefit only when Real-time Compression is used. IBM intends to enhance IBM Storwize Family Software for SVC to extend support of this feature to also benefit uncompressed workloads. 45 © 2014 IBM Corporation Summary - Storwize Family Software Version 7.3 " Supports new Storwize V7000 and new SVC engine " Supports additional expansion for Storwize V3700 and Storwize V5000 – Both systems now support up to 9 expansion enclosures " Easy Tier 3 " Storage Pool Balancing " Improved licensing model for Storwize V7000 and Storwize V5000 46 © 2014 IBM Corporation IBM Storage News IBM FlashSystem 840 © 2014 IBM Corporation IBM FlashSystem 840 Components Flash Modules (12) Batteries (2) RAID Controllers (2) Interface Modules (4) Canisters (2) Fans (4) Management Modules (2) Power Supplies (2) © 2014 IBM Corporation IBM FlashSystem 840 Physical Overview IBM FlashSystem 840 Front View Battery Modules Flash Modules "  Small 2U form factor can support up to twelve flash modules. 2 TB and 4 TB flash modules available. "  Hot swappable hardware components easily accessible from the front or back of unit. "  All hot swappable FRU and CRU can be replaced without removing unit from rack. Stacked units do not have to be removed for FRU CRU replacement. "  Capacity from 4TB up to 40TB © 2014 IBM Corporation IBM FlashSystem 840 Performance Performance Criteria1 Max Capacity (12 modules) Half Capacity (8 modules) Min Capacity (4 modules) Recommended 100% Read IOPS 1.1 M IOPS 1.1 M IOPS 1.0 M IOPS 10/15/13 Final 100% Write IOPS (burst) 600.0 k IOPS 400.0 kI OPS 225.0 k IOPS 10/15/13 Final 70% / 30% Mix 775.0 k IOPS 500.0 k IOPS 225.0 k IOPS 10/15/13 Final 100% Large Block Sequential Read 8.00 GB/s 8.00 GB/s 4.00 GB/s 10/15/13 Final 100% Large Block Sequential Write 4.00 GB/s 2.50 GB/s 1.00 GB/s 10/15/13 Final Min. Read Latency 135 us 135 us 135 us 10/15/13 Final Min. Write Latency 90 us 90 us 90 us 10/15/13 Final 1Data gathered using an Oakgate 2All measurements are made in a storage test appliance and a fiber channel protocol analyzer RAID 5 configuration, 4 TB cards, 90% of usable capacity © 2014 IBM Corporation IBM FlashSystem 840 Maximum Interface Port Counts " Fibre Channel 16Gb/s = maximum 8 ports. " Fibre Channel 8Gb/s = maximum 16 ports " Fibre Channel over Ethernet 10Gb/s = maximum 16 ports " Infiniband 40Gb/s = maximum 8 ports. " All hosts must have at least one connection to each RAID module to eliminate an outage during concurrent code load. " Note – 16Gb/s ports can also operate at 8Gb/s or 4Gb/s " Note – 8Gb/s ports can also operate at 4Gb/s © 2014 IBM Corporation IBM FlashSystem 840 GUI Preview - Monitoring © 2014 IBM Corporation Performance Scenario: Oracle RAC, 4 Nodes © 2014 IBM Corporation SVC VDISK Mirroring …across locations © 2014 IBM Corporation Question & Answer Time innovation that matters 55 © 2014 IBM Corporation