Preview only show first 10 pages with watermark. For full document please download

Ibm System I5 520 Express Configuration Enhancements Include

   EMBED


Share

Transcript

Hardware Announcement July 11, 2006  IBM System i5 520 Express Configuration enhancements include preload of IBM i5/OS V5R4 and new system console options Overview At a glance Building on the announcement of System i5 9405 520 Express Configurations and enhancements, additional function and flexibility is now being delivered. • • i5/OS V5R4 preloaded for new orders of the 520 Express Configurations Expanded console options Two new console choices are available for purchase when you initially order a 520 Express Configuration: • Thin console for System i5 (using the HMC port on the 520 system unit) • Operations Console (using an embedded Ethernet port) Enhancements to System i5 520 Express Configurations include: • i5/OS V5R4 preloaded on new Express Configuration orders • System console choices For ordering, contact: Your IBM representative, an IBM Business Partner, or the Americas Call Centers at 800-IBM-CALL Reference: AE001 Because these console options do not require an I/O processor (IOP) and do not use the PCI slots used by the previously available twinax console, you gain up to two additional PCI slots in the system unit. The twinax solution is available for clients who require it. Planned availability date August 11, 2006 This announcement is provided for your information only. For additional information, contact your IBM representative, call 800-IBM-4YOU, or visit the IBM home page at: http://www.ibm.com. IBM United States IBM is a registered trademark of International Business Machines Corporation. 106-523 Feature #5540 specifies the existing twinax console option. This option continues to provide a twinax controller (IOA) and a feature #9844 IOP at no charge. The IOA and IOP require two PCI slots in the system unit. With this configuration, the WAN adapter uses an IOP-based feature code designation and the feature #9844 IOP. Description The 9405 Model 520 system unit includes six PCI slots. Two new system console options allow you to free up to two of these valuable PCI slots previously used by a twinax controller and its associated IOP. The additional available PCI slots can help you delay or even avoid the need to add an I/O tower or drawers to gain PCI slots. Refer to Hardware Announcement 106-510, dated July 11, 2006, for additional information on the Thin Console for System i. The 9944 Model 100 Thin Console for System i is an easy-to-install, low-maintenance, fixed-function unit that provides a 5250 console interface. The thin console is manufactured by and carries the logo of Neoware, Inc., which offers its own maintenance and support. IBM is offering the thin console as a system console option for new Express Configuration orders. Feature #5552 specifies that one thin console be included in your 9405 520 order at no additional charge. Refer to Hardware Announcement 106-509, dated July 11, 2006, for additional information on System i5 enhancements. Section 508 of the U.S. Rehabilitation Act System i5 solutions are capable, when used in accordance with IBM′s associated documentation, of satisfying the applicable requirements of Section 508 of the Rehabilitation Act, provided that any assistive technology used with the product properly interoperates with it. The thin console attaches via an HMC Ethernet port on the system unit and does not require an IOA PCI slot or an IOP. This gives you up to two more PCI slots in the 520 system unit compared to the IOP+IOA-based twinax console. Business Partner information Thin console is a dedicated console for systems with a single i5/OS partition. It can also support a system with up to four Linux  partitions if only i5/OS virtual I/O is used by the Linux partitions. With this configuration, the WAN adapter uses an IOP-less feature number designation, and feature #9844 IOP is not included. If you are a Direct Reseller - System Reseller acquiring products from IBM, you may link directly to Business Partner information for this announcement. A PartnerWorld ID and password are required (use IBM ID). BP Attachment for Announcement Letter 106-523 You provide: • A standard monitor that supports 1024 x 768 resolution at 75Hz to plug into the logic unit of the thin console • A standard Ethernet cable up to 7.62 m (25 ft) that attaches the logic unit to the 520 system unit https://www.ibm.com/partnerworld/ mem/sla.jsp?num=106-523 Trademarks System i5, i5/OS, and System i are trademarks of International Business Machines Corporation in the United States or other countries or both. Linux is a trademark of Linus Torvalds in the United States, other countries or both. Other company, product, and service names may be trademarks or service marks of others. The thin console is supported only in the following countries: • • • • • • • • • • • • • • • • Austria Belgium Canada Denmark Finland France Italy Germany Netherlands Norway Portugal Spain Sweden Switzerland United Kingdom United States Feature #5553 specifies that the Operations Console with embedded Ethernet LAN attach be included in your order at no additional charge. With i5/OS V5R4, this previously announced LAN console can be attached without an IOP or PCI slot. The attachment is to one of two embedded Ethernet LAN ports, leaving the second port available for your applications. This i5/OS console option features a GUI that has more i5/OS function than a 5250 console interface. With this configuration, the WAN adapter uses an IOP-less feature number designation, and feature #9844 IOP is not included. If you choose to use the Operations Console, you must provide a PC and Ethernet cable and load the console application on the PC. 106-523 -2- IBM United States Announcement Supplemental Information July 11, 2006 − − − − − Additional information Feature availability matrix Order codes: • • • • I — Available on initial orders from the plant only M — Available on field upgrade (MES) orders only B — Available on both initial and field upgrade orders S — Supported for migration only and cannot be ordered For a complete list of features by model, refer to the System i  online Sales Manuals at http://www-306.ibm.com/common/ssi/OIX.wss |9| |4| |0| |5| | | |5| |2| |0| Feature | | Description 0296 0629 0630 0631 4688 5552 5557 9493 |M| |M| |M| |M| |M| |B| |M| |B| Custom Data Protection 4Gbps Fibre Channel (1-Port) PCI-X 1Gbps iSCSI TOE-Copper PCI-X 1Gbps iSCSI TOE-Optic 160GB VXA-320 Tape Drive Sys Console on Thin Console Sys Console-Ethernet No IOP Base PCI WAN for ECS Minimum required: 0 Maximum allowed: N/A OS level required: i5/OS V5R3, or later Initial Order/MES/Both/Supported: MES CSU: Yes (#0629) — 4Gbps Fibre Channel (1-Port): Provides a 4Gbps single port fibre channel PCI-X 2.0 adapter, which is a 64-bit address/data, short form factor PCI-X adapter with an LC type external fiber connector. It enables a single initiator over an optical fiber link or loop. With the use of appropriate optical fiber cabling, this adapter enables you to set up a network of high-speed local and remote storage. This feature is for use only in AIX and Linux partitions. The #0629 will auto-negotiate for the highest data rate between adapter and an attaching device at 1Gbps, 2Gbps, or 4Gbps of which the device or switch is capable. Distances of up to 500 meters running at 1Gbps data rate, up to 300 meters running at 2Gbps data rate, and up to 150 meters running at 4Gbps data rate are supported between the adapter and an attaching device or switch. When used with IBM supported fibre channel storage switches supporting long-wave optics, distances of up to 10 kilometers are capable of running at either 1, 2, or 4Gbps data rates. #0629 can be used to attach devices either directly or by means of fibre channel switches. If attaching a device or switch with an SC type fiber connector, an LC-SC 50 Micron Fiber Converter Cable (#0371) or an LC-SC 62.5 Micron Fiber Converter Cable (#0372) is required. • Attributes provided: One port fibre channel adapter Feature descriptions • Attributes required: One empty PCI-X slot Following are the descriptions, in numeric order, for all features in this announcement. • For 9405-520: (#0629) Attributes, as defined in the descriptions, state the interaction of requirements among features. Minimums and maximums are the absolute limits for a single feature without regard to interaction with other features. The maximum valid quantity for MES orders may be different than for initial orders. The maximums in the following list refer to the largest quantity of these two possibilities. The order type defines whether a feature is orderable only on initial orders, only on MES orders, on both initial and MES orders, or if a feature is supported on a model only as a result of a model conversion. − Minimum required: 0 − Maximum allowed: 34 (Initial order maximum: 0) − OS level required: AIX 5L for Power V5.2 for IBM eServer  , or later, Red Hat Enterprise Linux AS for POWER Version 4, or later, SUSE Linux Enterprise Server 9 for POWER, or later − Initial Order/MES/Both/Supported: MES − CSU: Yes (#0296) — Custom Data Protection: #0296 specifies that a system has multiple i5/OS  partitions and that data protection schemes should be considered separately for each partition instead of only for an overall system level. Each partition′s data protection scheme can be different or the same. (#0630) — PCI-X 1Gbps iSCSI TOE-Copper: Provides a 1Gbps iSCSI TOE PCI-X adapter that encapsulates SCSI commands and data into TCP and transports them over the Ethernet via IP packets. The adapter operates as a TCP/IP Offload Engine (TOE). This offload of the host eliminates protocol processing and reduces CPU interrupts. The adapter uses RJ45 1Gbps Ethernet connector. This iSCSI adapter can be used to initiate requests to external storage devices from AIX 5L and Linux partitions. • • For 9405-520: (#0296) Attributes provided: processing Offload of host protocol This announcement is provided for your information only. For additional information, contact your IBM representative, call 800-IBM-4YOU, or visit the IBM home page at: http://www.ibm.com. IBM United States IBM is a registered trademark of International Business Machines Corporation. 106-523 • Attributes required: Available PCI-X slot − Maximum allowed: 12 (Initial order maximum: 0) • For 9405-520: (#0630) − OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER V3, or later, SUSE Linux Enterprise Server 9 for POWER, or later − Initial Order/MES/Both/Supported: MES − CSU: Yes − Minimum required: 0 − Maximum allowed: 15 (Initial order maximum: 0) − OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, SUSE Linux Enterprise Server 9 for POWER, or later − Initial Order/MES/Both/Supported: MES − CSU: Yes (#5552) — Sys Console on Thin Console: This specify indicates the use of a thin console for the system console. The Thin Console is attached to an Ethernet port of the system unit′s service processor and does not take away an Ethernet port from i5/OS. (#0631) — PCI-X 1Gbps iSCSI TOE-Optic: Provides a 1Gbps iSCSI TOE PCI-X adapter that encapsulates SCSI commands and data into TCP and transports them over the Ethernet via IP packets. The adapter operates as an iSCSI TOE. This offload of the host eliminates protocol processing and reduces CPU interrupts. The adapter uses small form factor LC type fiber optic connector. This iSCSI adapter can be used to initiate requests to external storage devices from AIX 5L and Linux partitions. • Attributes provided: processing Offload of host • Attributes provided: System Console connection through the service processor Ethernet port • Attributes required: service processor Ethernet port • For 9405-520: (#5552) − protocol Minimum required: 0 − Maximum allowed: 1 (Initial order maximum: 0) − OS level required: i5/OS V5R3, or later • Attributes required: Available PCI-X slot − Initial Order/MES/Both/Supported: Both • For 9405-520: (#0631) − CSU: Yes − Minimum required: 0 − Maximum allowed: 15 (Initial order maximum: 0) − OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, SUSE Linux Enterprise Server 9 for POWER, or later − Initial Order/MES/Both/Supported: MES − CSU: Yes (#5557) — Sys Console-Ethernet No IOP: This specify indicates that the system console is driven by an IOP-less Ethernet LAN adapter. This LAN adapter must be dedicated to console support functions and cannot be used for any other purpose. (#4688) — 160GB VXA-320 Tape Drive: Provides a 160GB native capacity (320GB compressed capacity) VXA-320 tape device that installs in a half-high removable media device slot in an expansion unit. The #4688 reads and writes VXA-320 and VXA-2 format tapes and reads VXA-1 format tapes. • Attributes provided: System Console connection through an IOP-less Ethernet LAN adapter • Attributes required: Adapter • For 9405-520: (#5557) Characteristics: • Capacity: 160GB native compression mode • Form factor: 5.25-inch, half-high • Mounting type: auto-docking • Media: VXA tape data cartridges • Technology: Helical scan, rotating head • Operation: Streaming • Data transfer rate: 12MBps native mode, 24MBps (typical) compression • Interface: Ultra2 SCSI, 16-bit (wide), LVD and SE compatible • Compatibility: VXA-320 format (Read/Write), VXA-2 format (Read/ Write), VXA-1 format (Read) • Attributes provided: 160/320GB VXA-320 Tape Device • Attributes required: One Removable Media Device Slot • For 9405-520: (#4688) − mode, 320GB 5.25-inch, (typical) − Minimum required: 0 − Maximum allowed: 1 (Initial order maximum: 0) − OS level required: i5/OS V5R4, or later − Initial Order/MES/Both/Supported: MES − CSU: Yes (#9493) — Base PCI WAN for ECS: The #9493 is a WAN with modem adapter that provides connectivity for IBM Electronic Customer Support (ECS) only. This feature is the non-Complex Impedance Matching (CIM) version offered in all countries except Australia and New Zealand. #9493 is functionally equivalent to #0614, #2793, and #9793, but #9493 indicates to IBM configurator tools that the IOA is being used by i5/OS in an IOP-less mode. When in IOP-less mode, the adapter function is restricted to communicating to IBM ECS on port 0 (modem port). Port 1 is the RVX port and is not supported in an IOP-less mode. Port 0 supports V.92 56K PPP, V.92 data modem, and V.44 data compression. Port 0 does not provide synchronous modem capabilities (SDLC and synchronous PPP). Select one of the following cables to attach to port 0 (modem port): Half-high • • • Minimum required: 0 106-523 PCI-X IOP-less Ethernet LAN -2- #1010 Modem Cable — Austria #1011 Modem Cable — Belgium #1012 Modem Cable — Africa • • • • • • • • • • • • #1013 #1014 #1015 #1016 #1017 #1018 #1020 #1021 #1022 #1023 #1024 #1025 Modem Modem Modem Modem Modem Modem Modem Modem Modem Modem Modem Modem Cable Cable Cable Cable Cable Cable Cable Cable Cable Cable Cable Cable — Israel — Italy — France — Germany — U.K. — Iceland/Sweden — Hong Kong/New Zealand — Finland/Norway — Netherlands — Switzerland — Denmark — U.S./Canada Technical information Physical specifications: Web site at Visit the System i5  planning http://www.ibm.com/eserver/iseries/infocenter Select Language, V5R4, then Plan for Hardware and Software. Operating environment: Visit the System i5 planning Web site at The #9493 does not support the remote ring indicate function. This feature has country-specific usage. http://www.ibm.com/eserver/iseries/infocenter • Attributes provided: One integrated modem port for communication with IBM ECS Select Language, V5R4, then Plan for Hardware and Software. • Attributes required: One PCI slot (3 volt) • For 9405-520: (#9493) Software requirements: System i5 models with the advanced POWER5 processors require i5/OS V5R3, or later, and some features may require updates. For additional prerequisite information, visit − Minimum required: 0 − Maximum allowed: 1 (Initial order maximum: 1) − OS level required: i5/OS V5R3 with V5R3M5 Machine Code, or later System i5 models with the advanced POWER5 processors support: − Initial Order/MES/Both/Supported: Both − CSU: Yes • • • http://www-912.ibm.com/e_dir/eServerPrereq.nsf AIX 5L for POWER V5.2, or later Red Hat Enterprise Linux AS for POWER V4, or later SUSE Linux Enterprise Server 9 for POWER, or later Planning information Publications Cable orders: No cable orders required No publications are shipped with the announced features. Supplies Services • 80GB VXA-2 Tape Drives − IBM Integrated Technology Services Data cartridges (write and read): ------- IBM services include business consulting, outsourcing, hosting services, applications, and other technology management. These services help you learn about, plan, install, manage, or optimize your IT infrastructure to be an On Demand Business. They can help you integrate your high-speed networks, storage systems, application servers, wireless protocols, and an array of platforms, middleware, and communications software for IBM and many non-IBM offerings. IBM is your one-stop shop for IT support needs. − • − 1 http://www.ibm.com/services/learning/index.html IBM IBM IBM IBM V23 Data Cartridge (19P4876) 80GB X6 Data Cartridge (24R2134) 20GB1 X10 Data Cartridge (24R2136) 40GB 1 X23 Data Cartridge (24R2137) 80GB 1 Test and cleaning cartridges: --- For details on education offerings related to specific products, visit 20 Usage Cleaning Cartridge (19P4880) 80 Usage Cleaning Cartridge (24R2138) V6 Test Cartridge (19P4879) X6 Test Cartridge (24R2135) Data cartridges (write and read): ----- http://www.ibm.com/services/ http://www.ibm.com/services/continuity IBM IBM IBM IBM 160GB VXA-320 Tape Drives − For details on available IBM Business Continuity and Recovery Services, contact your IBM representative or visit V6 Data Cartridge (19P4878) 20GB V17 Data Cartridge (19P4877) 59GB V23 Data Cartridge (19P4876) 80GB X6 Data Cartridge (24R2134) 20GB X10 Data Cartridge (24R2136) 40GB X23 Data Cartridge (24R2137) 80GB Test and cleaning cartridges: ----- For details on available services, contact your IBM representative or visit IBM IBM IBM IBM IBM IBM IBM 80 Usage Cleaning Cartridge (24R2138) IBM X6 Test Cartridge (24R2135) Native capacities double with VXA-320 format. All data cartridge capacities shown are uncompressed. Select your country, and then select the product as the category. Sales and support You can get assistance, answers to product-related questions, or arrange for a warranty product replacement -3- 106-523 — with just one call. To locate your nearest source for ordering IBM Media Products, call the following numbers worldwide: • 888-IBM-MEDIA (426-6334) in the United States and Canada • +1-972-881-0733 in Latin America and Asia/Pacific • +31-433-502-756 in Europe, the Middle East and Africa • +81-3-3808-8486 in Japan To learn how Electronic Services can work for you, visit http://www.ibm.com/support/electronic Terms and conditions Feature section Same license machine. For additional product information and country-specific phone numbers, visit terms conditions as designated Prices http://www.ibm.com/storage/media Features and specify codes Security, auditability, and control System i5 uses the security and auditability features of IBM i5/OS. Use of these facilities is optional. The security measures supplied by i5/OS are designed to reduce the risk of users changing or destroying data resources, but do not prevent it. The i5/OS security features include the use of passwords, a security option to limit a user to only functions provided by customer-designed menus, and a security option to limit read/write access for files, libraries, and folders during normal operations. To achieve increased security, the i5/OS controls should be combined with physical security, division of duties, and other appropriate measures. Description Purchase ESA Feature price MMMC 24x7 CSU Custom Data Protection 4Gbps Fibre Channel (1-Port) PCI-X 1Gbps iSCSI TOE-Copper PCI-X 1Gbps iSCSI TOE-Optic 160GB VXA-320 Tape Drive Sys Console on Thin Console Sys Console-Ethernet No IOP Base PCI WAN for ECS 0296 0629 0630 0631 4688 5552 5557 9493 $ 0 2,646 1,191 1,853 1,500 0 0 0 Yes Yes Yes Yes $23 $20 Yes Yes Yes Yes Conversions The customer is responsible for evaluation, selection, and implementation of security features, administrative procedures, and appropriate controls in application systems and communications facilities. Feature conversions IBM Electronic Services IBM has transformed its delivery of hardware and software support services to put you on the road to higher systems availability. Electronic Services is a Web-enabled solution that provides an exclusive, no-additional-charge enhancement to the service and support available on the IBM eServer platform. These services provide the opportunity for greater system availability due to faster problem resolution and preemptive monitoring. Electronic Services comprises two separate, but complementary, elements: IBM Electronic Services news page and IBM Electronic Service Agent  . From To: Parts returned Purchase price 5761 5783 5784 6279 0629 0630 0631 4688 9793 0629 0630 0631 4688 5761 5783 5784 6279 9493 No No No No No No No No No $ 0 0 0 300 0 0 0 300 0 Order now To order, contact the Americas Call Centers, your local IBM representative, or your IBM Business Partner. To identify your local IBM representative or IBM Business Partner, call 800-IBM-4YOU (426-4968). Electronic Services news page is a single Internet entry point that replaces the multiple entry points traditionally used to access IBM Internet services and support. The news page enables you to gain easier access to IBM resources for assistance in resolving technical problems. Phone: Fax: Internet: Mail: The Electronic Service Agent is no-additional-charge software that resides on your IBM eServer system. It monitors events and transmits system inventory information to IBM on a periodic, customer-defined timetable. The Electronic Service Agent tracks system inventory, hardware error logs, and performance information. If the server is under a current IBM maintenance service agreement or within the IBM warranty period, the Service Agent automatically reports hardware problems to IBM. Early knowledge about potential problems enables IBM to provide proactive service that may result in higher system availability and performance. In addition, information collected through the Service Agent is made available to IBM service support representatives when they help answer your questions or diagnose problems. 106-523 and 800-IBM-CALL (426-2255) 800-2IBM-FAX (242-6329) [email protected] IBM Americas Call Centers Dept. Teleweb Customer Support, 9th floor 105 Moatfield Drive North York, Ontario Canada M3B 3R1 Reference: AE001 The Americas Call Centers, our national direct marketing organization, can add your name to the mailing list for catalogs of IBM products. Note: Shipments will begin after the planned availability date. -4- Trademarks System i, i5/OS, AIX 5L, POWER, System i5, iSeries, POWER5, and Electronic Service Agent are trademarks of International Business Machines Corporation in the United States or other countries or both. AIX and eServer are registered trademarks of International Business Machines Corporation in the United States or other countries or both. Linux is a trademark of Linus Torvalds in the United States, other countries or both. Other company, product, and service names may be trademarks or service marks of others. -5- 106-523