Preview only show first 10 pages with watermark. For full document please download

Ibm Totalstorage Network Attached Storage 300 Delivers Superior

   EMBED


Share

Transcript

Hardware Announcement June 12, 2001  IBM TotalStorage Network Attached Storage 300 Delivers Superior Performance and Availability Overview IBM′s TotalStorage Network Attached Storage 300 (NAS 300) is an integrated storage product that is system-tested and comes with all components completely assembled into a 36U rack. It provides superior networked attached storage for the small to mid-sized enterprise. If your business is faced with expanding Internet use, e-business operation, enterprise resource planning and large data management, the NAS 300 provides the solutions you need including high reliability and availability, and ease of managing remotely. Designed for today′s demanding environment, it also provides the flexibility and scalability required to meet future capacity demands. The Network Attached Storage 300 system will scale easily from 360 GB to 3.24 TB, making future expansion simple and cost-effective. The preloaded operating system and application code is tuned for the network storage server function, and designed to provide maximum uptime. The simple point-and-click restore feature makes backup a breeze. With multi-level persistent images capability, recovery is quickly managed to ensure highest availability and reliability. • • • • One Rack 36U (with state-of-art Power Distribution Unit) Two Engines, each with: − Dual 933 MHZ processors − 1 GB memory (expandable to 2 GB) − Two Redundant and hot swap power supplies/fans Two Fibre Channel Hubs One RAID Storage Controller − 10 36.4 GB Hot Swappable HDD • • IBM TotalStorage Network Attached Storage Family The IBM NAS 300 is a member of IBM′s Network Attached Storage family of products, which are specifically designed, configured, and packaged to provide solutions to overcome the challenges of sharing, managing, and protecting your data and your investment within complex network infrastructures. Key Prerequisites • Ready To Go This Network Attached Storage system comes ready to be installed and become a part of a productive environment with minimal effort. The NAS 300 (5195 Model 325) features the following: At a Glance • IBM TotalStorage NAS 300 connects to an Ethernet LAN. Customer-supplied Ethernet cabling must be used to connect to the LAN. This rack-mounted system provides for power distribution, however, sufficient power must be provided to the rack. Refer to the Hardware Requirements section for details. • • • • Planned Availability Date July 13, 2001 • Fully assembled and tested solution, ready to go Designed for maximum availability − Dual node engines for clustering and fail-over − Dual Fibre channel hubs for high speed data transfer and reduced contention − Hot Swap power supplies and fans for system redundancy − Light-Path Diagnostics for improved on-board diagnostics − Automatic preloaded operating system recovery Connectivity − Supports high-speed Gigabit and 10/100 Ethernet LAN connectivity − Fiber-to-fiber technology Functionality − Preloaded operating system optimized for Windows and UNIX client servers − Supports multiple RAID levels Scalability − Easily scales from 360 GB to 3.24 TB for future growth Easy of use − Web-based GUI − Simple point-and-click restore using NTBackup (utility) Simple Management − Superior management software for high availability For ordering, contact: Your IBM representative, an IBM Business Partner, or IBM Americas Call Centers at 800-IBM-CALL Reference: SE001 The system comes standard with dual-node engines for clustering and fail-over protection. The dual Fibre Channel Hubs provide the most savvy IT administrators with high performance paths to the RAID storage controllers using high speed fibre-to-fibre technology. This announcement is provided for your information only. For additional information, contact your IBM representative, call 800-IBM-4YOU, or visit the IBM home page at: http://www.ibm.com. IBM United States IBM is a registered trademark of International Business Machines Corporation. 101-171 For high performance data handling, Fibre Channel cabling is used for disk connectivity. Optionally, the IBM TotalStorage NAS 300 can be enhanced by adding: Description The IBM TotalStorage Network Attached Storage 300 consists of the following machines: • • IBM 5186 NAS Rack Model 36U • • Two IBM 5187 NAS Engine Model 5RZs • Two 3534 SAN Model 1RUs • IBM 5191 NAS RAID Storage Controller Model 2RU (one line removed) Fibre Channel Managed An additional 5191 NAS RAID Storage Controller Model 2RU Up to seven 5192 NAS Storage Unit Model 1RUs The Rack is preconfigured with Fibre Channel cabling for all such expansions. Hub The base IBM TotalStorage NAS 300 is configured with 360 GB of HDD. Additional HDD can be added in eight 360 GB increments to a maximum configuration of 3.24 TB by adding IBM 5192 NAS Storage Unit Model 1RU and IBM 5191 NAS RAID Storage Controller Model 2RU optional features. IBM TotalStorage NAS 300 is preinstalled in the rack with optimized software preloaded. The entire system is tested by IBM prior to delivery. You can install your IBM TotalStorage NAS 300 quickly and easily. Product Structure 101-171 -2- Columbia Data Products Persistent Storage Manager for IBM NAS Product: Persistent Storage Manager (PSM) creates True Images (multiple point-in-time persistent images of any or all system and data volumes). All persistent images survive system power loss or a planned or unplanned reboot. Each instance of PSM seamlessly handles 250 concurrent images of up to 255 independent volumes for a total of 63,750 independent data images. Any image can be easily managed through the Microsoft Web user interface, and accessed the same as any other active volume. In case of data corruption or loss, any persistent image can be used for manual retrieval of individual files (by the administrator or end users), or more importantly, for instant restoration (by a PSM function initiated by the administrator, in the Web user interface) of the entire volume from image, which can substantially reduce the amount of system down time. Preloaded System Code Optional Network Management Software Each IBM TotalStorage NAS 300 is preloaded at the factory with base operating and system and application code. The code is loaded to the system′s hard disk with a backup copy provided on CD-ROM. The operating system and NAS application code has been specifically tuned to enable the Model 325 as a high performance NAS appliance. In addition to the operating system and application code, the code load contains configuration and administration tools which simplify remote configuration and administrator tasks. Network management agents are included that provide options by which the IBM TotalStorage NAS 300 can be managed. The preloaded code contains the following functions: Preloaded Operating System and Application Code Functions • Persistent Storage Manager creates and keeps multiple point-in-time persistent images. (maximum of 250 concurrent images of up to 255 independent volumes) • All images for a volume are mounted under a single directory (in the root directory of the volume), with each image under its own mount point. Windows Powered OS • Optimized for IBM TotalStorage NAS 300 − File Systems Supported • CIFS, NFS, FTP, HTTP, Novell Remote NAS System Administration • Administrative task performed in the Web-based GUI • IBM Advanced Appliance Configuration Utility • Alternate administrative Windows Terminal Service • Advanced management functions Windows Terminal Service • Simple point-and-click for restores using NT Backup • NAS Backup Assistant MMC Snap-in Web page task performed • Images can be read-only, or read-write (with ability to reset (undo changes to) read-write images). • Images can be assigned retention levels (if an image needs to be automatically deleted by PSM, the highest priority images can be kept). • Any image can be used to restore an entire volume instantly (for data volumes, typically within seconds; for system volume, system reboot is required) • Image access and administration via Web-based user interface is flexible and configurable. using available via User-level access can be granted to one or more of the images, to allow users to restore their own files from the images (users will automatically have the same access privileges to individual files and directories in the images that they would have on the actual volume). − Schedule images (for each schedule entry (image group), specify interval, number to keep, image name, properties (read-only or read-write, retention level)) − Create a new image immediately (specify name and properties) Disaster Recovery of Operating System − Delete images • Customer scheduled backups of the system partition − • Fifteen minute original factory CD-ROM reload of operating system View and change properties of images (also reset read-write images) − Restore a volume (from any image of that volume) − Configure advanced parameters − Maximum number of images to keep concurrently UNIX Services • • • • • Preconfigured NFS support Web-based GUI for performing administrative tasks Microsoft  Services for UNIX V2.2 NFS V3.0 (IETF RFC 1830) Prevention of accidental enablement diskette reloads via reload IBM Fibre Management Utility − Name of image root directory • IBM Fibre Stand Alone management utility − Quiescent period and quiescent period wait timeout • MMC snap-in that launches the utility − Size of the image cache file (per volume) • Advanced users will find it useful to monitor the Fibre adapter configuration − Image cache file usage warning and automatic image deletion thresholds (per volume) Advanced Aggregate Management • Netfinity Director with Universal Manageability (UM) Services V2.12 Netfinity  Director Agent The IBM TotalStorage NAS 300 contains a Netfinity Director agent and can be managed by this powerful, highly-integrated, systems management software solution -3- 101-171 that is built upon industry standards and designed for ease-of-use. With intuitive Java  -based GUI, an administrator can centrally manage individual or large groups of IBM and non-IBM PC-based engines. IT administrators can view the hardware configuration of remote systems in detail and monitor the usage and performance of crucial components, such as processors, disks, and memory. V2.12 supports Windows Operating Systems. 2000 and SCO IBM 5187 NAS Engine Model 5RZ The engine brings high performance, power, and function to NAS processing. It is designed and configured for maximum computing power in support of file intensive applications. Using two-way, SMP-capable, 133 MHz front-side bus (FSB) Pentium III processors coupled with a 64-bit PCI bus and Ultra160 SCSI, these engines are designed for high performance. They are packaged in a compact 3 U mechanical package within the 5186 NAS Rack Model 36U. UnixWare The following functions have been added in V2.12: • Windows 2000 engine, console, and agent. • SCO UnixWare agent. • Alert on LAN  — (AOL) configuration enhancements. • Wired for Management — (WfM) — compliant CIM to DMI Mapper. • SNMP device listener for Netfinity hardware. • NF Director with UM Services V2.12 replaces all earlier versions of NF Director and UM Services and adds support for Windows 2000, SCO UnixWare, and new IBM hardware systems. They incorporate two powerful 933 MHz Pentium III processors with 256 KB advanced transfer L2 cache. The advanced transfer cache is the result of a “backside bus” that is 256 bits wide. The quad-wide cache line can transfer four 64-bit cache line segments at one time to deliver full-speed data handling. High-speed, 133 MHz SDRAM is optimized for 133 MHz processor-to-memory subsystem performance. The 5187 NAS Engine Model 5RZ uses the ServerWorks ServerSet III LE (CNB3.0LE) chipset to maximize throughput from processors to memory, and to the 64-bit and 32-bit PCI buses. In addition to the integrated 10/100 Ethernet controller, which is exclusively used to communicate between the two engine nodes, at least one of either the 10/100 Ethernet adapter (#0005) or Gigabit Ethernet adapter (#0006) must be ordered with each engine of the configuration to connect to the Ethernet LAN for access by the users. Refer to Software Announcement 200-084, dated April 18, 2000, for further information on Netfinity Director with UM Services V2.12. Tivoli Storage Manager The IBM TotalStorage NAS 300 is enabled with the Tivoli Storage Manager backup client that can be used to backup data to a Tivoli Storage Manager server. This backup client provides file level and sub-file level backup and restore functionality. Engine characteristics include: Tivoli Storage Manager is a full-function storage software solution that addresses the challenges of complex storage management across a distributed environment. It manages a broad range of data storage, recovery, and availability functions across your entire computing infrastructure, regardless of platform, vendor, or operating system. From the massive enterprise file engines in your data center to the storage peripherals throughout your organization and to the laptops in your remote offices, Tivoli Storage Manager ensures data availability for all users, wherever they are. Tivoli Storage Manager enables organizations with large amounts of mission-critical data held on distributed heterogeneous platforms to manage that data from up to seven different platforms including Windows 2000, Sun Solaris, HPUX, IBM AIX , OS/390 , VM, and OS/400 . For additional information on Tivoli Storage Manager, refer to the following Web site: http://www.tivoli.com/storage • Two 933 MHz Pentium III processor with 133 MHz front-side bus (FSB) and 256 KB ECC L2 advanced transfer (full-speed) cache • 1 GB of 133 MHz system memory--expandable to 2 GB • Dual-channel Ultra160 controller--supports high-speed, high-capacity internal disk storage solutions for IPL • Two redundant 270 W auto-ranging, load-sharing power supplies for high availability • Integrated Advanced System Management Processor • Five PCI slots 33 MHz PCI expansion slots, three 64-bit and two 32-bit • Standard diskette drive and 40x-17x3 CD-ROM and two 5.25-inch bays • One 9.1 GB 10K-4 FC Hot-Swap HDD • Integrated 10/100 Mbps Ethernet controller (for engine-to-engine communication on the IBM TotalStorage NAS 300) • Two serial ports (16550A-compatible), one parallel port, two USB ports, system management port, mouse port, and keyboard port IBM 5186 NAS Rack Model 36U • The rack is an integral part of the IBM TotalStorage NAS 300. All constituent machines and options are mounted and housed within the rack. It is capable of housing the maximum IBM TotalStorage NAS 300 configuration. Hot-swap power supplies for the most robust 7x24 operation • Several hardware features must be ordered with the 5186 NAS Rack Model 36U. These features are described below. Refer to the Hardware Requirements section for details of the ordering requirements. Predictive Failure Analysis  (PFA) on processors, voltage regulator module (VRM), memory, fans, power supplies, and HDD options — warn of problems before they occur • Servicing is fast and easy--Light-Path Diagnostics, improved on-board diagnostics, and LED diagnostic panel 101-171 -4- Light-Path Diagnostics, and customer-replaceable units (CRUs) are used throughout to minimize downtime and service costs. The HDDs are hot-swappable; using the RAID capabilities, there is no downtime or loss of data when replacing a failed HDD. 3534 SAN Fibre Channel Managed Hub Model 1RU The FC hub provides industry-standard Fibre Channel Arbitrated Loop (FC-AL) connectivity of the homogeneous cluster of IBM 5187 NAS Engine Model 5RZs and storage systems. An arbitrated loop is logically formed by connecting all eight ports on the Hub into a single loop. The ports also can be zoned into several arbitrated loops. Each port supports 100 MB/second full duplex data transfer. In addition to non-blocking architecture, the Managed Hub can handle simultaneous data transfer which provides superior data handling performance. Features include: The Managed Hub is an integrated rack-mounted component that is serviced as a single replaceable unit. A power cord for connecting to the Power Distribution Unit (PDU) in the rack is included with the rack. The 3534 SAN FC Managed Hub Model 1RU comes installed in the 5186 NAS Rack Model 36U. 1U space and one outlet on the rack PDU are used. Attachment to 5187 NAS Engine Model 5RZs and 5191 NAS RAID Storage Controller Model 2RUs is via fiber optic cables which are provided by IBM as part of the rack and installed at the factory as part of the assembly/testing process. The 5191 NAS RAID Storage Controller Model 2RU combines internal redundant RAID controller technology and hot-swap HDD storage into a highly integrated, 3U mechanical package. They contain: Two 350W, auto-ranging, hot-swap, redundant power supplies • Two internal redundant RAID controller modules • Two redundant fan canisters — each contain two blowers • Midplane — provides dual FC loops • LED indicators on all critical components warn of faults, over temperature, and other abnormalities for high manageability 100 MHz Intel 80960RN microprocessor with 64-bit, 33 MHz primary and secondary PCI buses • 128 MB of 64-bit SDRAM, 8-bit ECC protected, battery-backed cache • One GBIC host connector • One expansion port GBIC connector--allows connections of up to four Storage Units • Support for full-speed FC link rates • One RS-232 service interface--diagnostics port for trained service technicians Customer replaceable units, redundancy, and Light-Path diagnostic technologies are built into this highly-available storage unit. IBM 5191 NAS RAID Storage Controller Model 2RU • • The Storage Unit is a highly available data storage unit that supports high-performance, hot-swap Fibre Channel HDDs. This 3U storage enclosure supports four Netfinity Fibre Channel Short-Wave Gigabit Interface Converters (GBICs) that provide the optical fiber connection to IBM 5192 NAS Storage Unit Model 1RUs. Both single and dual loop configurations are supported. Note: When ordering the 3534 SAN FC Managed Hub Model 1RU for use with the IBM TotalStorage NAS 300, you must also specify the Specify Feature Number, 9295. Ten 3.5-inch, hot-swap HDD bays fully populated with 36.4 GB 10K-4 FC Hot-Swap HDD Support for RAID levels 0, 1, 3, and 5 IBM 5192 NAS Storage Unit Model 1RU For additional details, refer to Hardware Announcement 101-122, dated April 23, 2001. • • • Ten drive bays — populated with ten 36.4 GB 10K-4 FC Hot-Swap HDDs • Two hot-swap, 350 W auto-ranging redundant power supplies • Redundant fans — two hot-swap, dual-fan units • LED indicators on all critical components warn of faults, over temperature, and other abnormalities 5192 NAS Storage Unit Model 1RU and IBM 5191 NAS RAID Storage Controller Model 2RU Related Options: The 36.4 GB 10K-4 FC Hot-Swap HDD is a high-performance, 10,000 rpm HDD with Predictive Failure Analysis (PFA). While the IBM 5191 NAS RAID Storage Controller Model 2RU and the IBM 5192 NAS Storage Unit Model 1RU come fully configured with slots containing HDDs, this feature should be considered as an “on-the-shelf” replacement for any HDD that might fail. The hardware design and RAID technology allow for a hot-swap of the HDD with no downtime and no loss of data. The 5191 NAS RAID Storage Controller Model 2RU is cabled to both of the 3534 SAN Fibre Channel Managed Hub Model 1RUs and contains two RAID controllers to provide redundant paths with no single point of failure. A second, optional, 5191 NAS RAID Storage Controller Model 2RU can be ordered (initially, or customer installed later) to provide added storage, redundancy, performance, and availability. If the IBM TotalStorage NAS 300 configuration requires more than 1.8 TB of storage, a second 5191 Controller must be added to the configuration. IBM 5187 NAS Engine Model 5RZ Optional Features Each engine (node) of the 5187 NAS Engine Model 5RZ must have the identical number and type of Ethernet adapters installed. F/W Ultra SCSI Adapter (#0001) Before a second 5191 NAS RAID Storage Controller Model 2RU can be added to the IBM TotalStorage Network Attached Storage 300, four 5192 NAS Storage Unit Model 1RUs must be added. The second Controller supports up to three Storage Units. The IBM PCI Fast/Wide Ultra SCSI Adapter permits the attachment of high-speed Ultra SCSI backup tape drives to the engine. With data transfer speeds as high as 40 Mb/s and the adoption of innovations such as “Disconnect/Reconnect,” the PCI Fast/Wide Ultra SCSI Adapter accommodates fast storage devices with ease. This high data transfer rate is further enhanced by the use The 5191 NAS RAID Storage Controller Model 2RU is designed for easy service. Hot-plug components, -5- 101-171 The implementation of fail-over requires that the same number of feature 0005 and 0006 be installed in each engine of IBM TotalStorage NAS 300. of “Busmastering” Direct Memory Access (DMA) that allows the adapter to control the transfer of data from the peripherals to the system memory, relieving the engine processors of this time-consuming burden. 1 GB Memory Expansion (#0007) The SCSISelect configuration utility resident in the adapter′s BIOS allows simple, on-screen configuration of the adapter and eliminates the need to manipulate jumpers or terminations during installation. The NAS 300, 5195-325 system ships from the factory with one Gigabyte of memory installed on the system planar board of each engine as a standard feature. Two of the four DIMM memory sockets on the planar are populated with 512 MB DIMM memory modules for a total of one Gigabyte. Capable of supporting up to 15 devices at once, the PCI Fast/Wide Ultra SCSI Adapter can also handle a combination of 8-bit and 16-bit external tape drives (refer to the Technical Information section). To optimize NFS file transfer operations, a 1 GB memory expansion feature is available. This feature can be ordered factory installed in conjunction with new orders for a 5195-325 system and is also available as a field installable feature. The PCI Fast/Wide Ultra SCSI Adapter option kit provides a “Ready-to-Go” solution complete with a wide SCSI cable and all software required to configure the system. The installation consists of adding a Gigabyte of memory to the engine planar board by populating the two empty memory sockets with 512 MB modules. This upgrade increases memory to 2 Gigabytes which improves the performance of NFS file transfer operations. Management Adapter (#0004) The Advanced System Management PCI Adapter, in conjunction with the ASM processor that is integrated into the base planar board of the engines, allows extensive remote management of IBM TotalStorage NAS 300 via Ethernet LAN or modem connection from virtually anywhere. The ASM adapter enables more flexible management through a Web browser interface, in addition to ANSI terminal, Telnet, and Netfinity Director. Management Interconnect Cable (#0009) This feature may be installed in only one of the 5187 NAS Engine Model 5RZs. Feature number 0009 must also be ordered for the other engine. Extends the functions of the Management Adapter (#0004) to the second engine of the two node cluster. The Management Adapter is installed in only one of the two engines of the IBM TotalStorage NAS 300. The other engine of the pair must include this feature (#0009) when the Management Adapter is ordered. 10/100 Ethernet Adapter (#0005) Code Preload (#0203) The 10/100 Ethernet Adapter provides IEEE 802.3-compliant 100BASE-TX and 10BASE-T Ethernet connectivity for engines over an unshielded twisted pair link through a single RJ-45 connector. Its 32-bit PCI 2.1 bus mastering architecture offers outstanding performance with low engine CPU utilization. It provides half-duplex and full-duplex operation at both 10 Mbps and 100 Mbps. Auto-negotiation of speed and duplex mode facilitates the use of the adapter in shared or switched environments running at either speed. Provides the code that is preloaded by IBM. This feature must be ordered for each of the two engines of the configuration. IBM 5186 NAS Rack Model 36U Features All the Rack features are factory installed only. Filler Panels must be included in the order in sufficient numbers to cover all unpopulated rack positions. The number required is equal to nine minus the total number of IBM 5191 NAS RAID Storage Controller Model 2RUs and IBM 5192 NAS Storage Unit Model 1RUs. A minimum configuration consists of one IBM 5191 NAS RAID Storage Controller Model 2RU and no IBM 5192 NAS Storage Unit Model 1RUs, (9 - 1 = 8 filler panels). The configurator will calculate the correct number of filler panels required. In addition to fail-over from one engine to another within a given TotalStorage NAS 300 system, this adapter supports Ethernet fail-over from one adapter within a node to another adapter, should that link or adapter have an unrecoverable problem. The implementation of fail-over requires that the same number of feature 0005 and 0006 be installed in each engine of IBM TotalStorage NAS 300. 3U Filler Panel (#0002) Provides filler for a space of 3U in the IBM 5186 NAS Rack Model 36U. Gigabit Ethernet Adapter (#0006) The Gigabit Ethernet SX Adapter provides 1000BASE-SX connectivity to a Gigabit Ethernet network for the engines over a 50 or 62.5 micron multimode fiber optic link attached to its duplex SC connector. Its 1000 Mbps data rate and 32- or 64-bit PCI bus mastering architecture enable the highest Ethernet bandwidth available in an adapter. It is compliant with IEEE 802.3z Ethernet and PCI 2.1 standards, ensuring compatibility with existing Ethernet installations. It also supports 802.1p packet prioritization and 802.1q VLAN tagging. 5195-325 Wiring and Labeling (#0003) One feature #0003 must be included in the order for each IBM TotalStorage NAS 300. This feature provides the signal path between all of the machines that make up the IBM TotalStorage NAS 300 system. Power Utility Wiring 1 — 220 V (#0101) Provides power to the Power Distribution Unit (PDU) that is part of the IBM 5186 NAS Rack Model 36U from a 200-240 V ac, 30 amp, three-phase power source. If IBM TotalStorage NAS 300 is to be used where this is the power source, this feature must be specified when ordering. In addition to fail-over from one engine to another within a given TotalStorage NAS 300 system, this adapter supports Ethernet fail-over from one adapter within a node to another adapter, should that link or adapter have an unrecoverable problem. Power Utility Wiring 2 — 400 V (#0102) Provides power to the PDU that is part of the IBM 5186 NAS Rack Model 36U from a 380-415 V ac, 32 amp, 101-171 -6- distributed environment for retail or banking; a campus for education or government; or a centralized location for NetGen, financial, manufacturing or transportation. three-phase power source. If IBM TotalStorage Network Attached Storage Model 325 is to be used where this is the power source, this feature must be specified when ordering. The 200 series products provide: Accessibility by People with Disabilities For hardware offerings: The following features support use by people with disabilities: • • • Controls and latches are operable with one hand and minimal dexterity. Someone in a wheel chair may have a difficult time depending on where this appliance is installed. Keys are discernible by touch without activating them. There are industry-standard pressure sensitive contact switches. The user can glide their fingers over them without activating them. Ports and connectors industry-standard devices. support connection • High reliability via redundant, hot swap power supplies and HDDs so business operations can continue in the event of a sub-system failure • 250 persistent images to enable on-going backups for exceptional data protection • Scalable storage that allows customers to conserve their financial resources at initial purchase • Low-cost entry into network attached storage and affordable scalability as storage requirements grow • Multi-protocol support for CIFS (Windows), NFS (Unix), FTP, HTTP and Novell file systems enables the sharing of files between and within any of these environments, eliminating the need for separate, dedicated file engines for each protocol • Excellent performance to enhance productivity for users in both Windows and mixed Windows/Unix environments • Fully integrated, optimized storage so general purpose engines can focus on other tasks • Quick installation and integration into an IP network via an easy-to-use Web browser means that scarce IT resources will be committed to the set-up of the products for a minimal amount of time • On-board uptime assurance via the Advanced System Management processor with its Light Path Diagnostics, Predictive Failure Analysis and Remote Connect capabilities. of Euro Currency This product is not impacted by euro currency. Product Positioning The tower version of the 200 series is scalable from 108 to 216 GB, with an entry level price. The rack version of the 200 series is scalable from 216 GB to 1.74 TB. The TotalStorage NAS 300 provides an affordable but robust solution for the storage and file serving needs of either a department or a small enterprise. The 300 presents the same features and benefits as the 200 series products, but with these important additions: The IBM TotalStorage NAS 200 and 300 series products are designed to fill the storage and file serving needs of workgroup, departmental and small enterprise customers. The 200 series products, available in both a tower and rack configuration, are well suited for both workgroup and departmental applications. The 300 series with its rack configuration is targeted toward departmental and small enterprise applications. • A second engine — load sharing increases performance while increasing system reliability via the redundancy of another node • Enhanced performance so additional users in a department or small enterprise experience no impact to productivity • Highly scalable storage capacity ranging from 360 GB to 3.24 TB providing customer control of the initial purchase investment With their scalability, high reliability, performance and affordability, the NAS 200 and 300 products are designed to meet a host of requirements in demanding environments. These new NAS appliances are well suited for applications such as file serving or active storage in a traditional office environment and file serving or backup storage in a Web-hosting environment. They are also excellent solutions for active and backup storage in either an engineering or transaction setting. The 200 and 300 series adapt well to a variety of settings such as a -7- 101-171 Trademarks Alert on LAN is a trademark of International Business Machines Corporation in the United States or other countries or both. Netfinity, AIX, OS/390, OS/400, Predictive Failure Analysis, and Wave are registered trademarks of International Business Machines Corporation in the United States or other countries or both. Pentium is a trademark of Intel Corporation. Microsoft is a trademark of Microsoft Corporation. Windows is a registered trademark of Microsoft Corporation. Java is a trademark of Sun Microsystems, Inc. UNIX is a registered trademark is a registered trademark of the Open Company in the United States and other countries. Tivoli is a registered trademark of International Business Machines Corporation or Tivoli Systems Inc. in the United States or other countries or both. Other company, product, and service names may be trademarks or service marks of others. 101-171 -8- IBM US Announcement Supplemental Information June 12, 2001 IBM 5187 NAS Engine Model 5RZ Publications Dimensions (per engine) The following publication is shipped with the product. The Installation Guide ships as hard copy and on CD-ROM. All others ship on CD-ROM. All but Documentation V2 are available on the Web. Form Number Part Number IBM TotalStorage Network Attached Storage 300 Installation Guide GA27-4275 42P0002 IBM TotalStorage Network Attached Storage 300 User′s Reference GA27-4276 NA IBM TotalStorage Network Attached Storage 300 Release Notes NA 38P7713 IBM TotalStorage Network Attached Storage 300 Documentation V2 NA Title 3 U Rack Drawer − Width: 414.0 mm (16.3 in) − Depth: 660.4 mm (26 in) − Height: 133.4 mm (5.25 in) − Weight: -- 20.0 kg (44 lb) (minimum configuration) -- 28.1 kg (62 lb) (maximum configuration) 3534 SAN Fibre Channel Managed Hub Model 1RU 42P0001 The IBM TotalStorage Network Attached Storage 300 Service Guide (GY27-0402) is available immediately. To order, contact your IBM representative. The Publication Notification System (PNS) is available by Form Number. Customers currently subscribing to PNS will automatically receive notifications by e-mail. Customers who wish to subscribe can visit the PNS Web site location at: http://www.ibm.com/shop/publications/pns/ The publications listed on the notification can be ordered by calling the Pubs Support Group in Raleigh at 800-879-2755, option 1. The IBM Publications Center Portal: http://www.ibm.com/shop/publications/order The Publications Center is a WW central repository for IBM product publications and marketing material with a catalog of 70,000 items. Extensive search facilities are provided, as well as payment options via credit card. Furthermore, a large number of publications are available online in various file formats, which can currently be downloaded free of charge. Note that PNS subscribers most often order their publications via the Publication Center. Technical Information Specified Operating Environment Physical Specifications • • • • • Height — Rack Mount: 4.37 cm (1.72 in) Width: 42.85 cm (16.87 in) Depth: 25.48 cm (10.03 in) Weight: 4.1 kg (9 lb) IBM 5191 NAS RAID Storage Controller Model 2RU • • • • Approximate Approximate Approximate Approximate height: 128.0 mm (5.0 in) width: 447.0 mm (17.6 in) depth: 575.0 mm (22.6 in) weight with HDDs: 35.5 kg (78 lb) IBM 5192 NAS Storage Unit Model 1RU • • • • Approximate Approximate Approximate Approximate height: 128.0 mm (5.0 in) width: 447.0 mm (17.6 in) depth: 575.0 mm (22.63 in) weight: 34.1 kg (75 lb) 5187 NAS Engine Model 5RZ • Processor: Pentium III • Internal Speed: 933 MHz • External Speed: 133 MHz • Number Standard: 2 • Maximum: 2 • L2 Cache: 256 KB (full speed) • Memory (133 MHz SDRAM) 1 GB ECC − − − RDIMMs: 2 x 512 MB DIMM Sockets: 4 Capacity: 2 GB (2 GB maximum supported for application) • Ultra SCSI Controller: Wide Ultra SCSI • Fixed Disk: 9.1 GB for OS and application storage • Total Slots: 5 − − − PCI (33 MHz): 5 64-bit: 3 32-bit: 2 This announcement is provided for your information only. For additional information, contact your IBM representative, call 800-IBM-4YOU, or visit the IBM home page at: http://www.ibm.com. IBM United States IBM is a registered trademark of International Business Machines Corporation. 101-171 • Slots Available: 4 (2 — 64 bit, 2 — 32 bit slots for options) Management Processor — Standard • 1-port Fibre Channel connection) — Standard • Management Adapter (Optional) • Optional Ethernet Adapters − − Adapter (Fiber Equipment Approvals and Safety Channel 1-port Ethernet: 10/100 Mbps (Network connections) 1-port Ethernet: Gigabit Base1000-SX (Network connections) • FCC — Verified to comply with Part 15 of the FCC Rules, Class A • Canada ICES-003, issue 3, Class A • UL 1950 • CSA C22.2 No. 950 • NOM-018 3534 SAN FC Managed Hub Model 1RU • 1-port 10/100 Ethernet (Internodal communications, on planar) • CD-ROM (IDE): 24x-10x • Diskette Drive: 1.44 MB • Power Supply: 270 W • Number standard: 2 • Hot-Swap: Yes • Redundant Power: Yes • Auto Restart: Yes EMC Conformance • Temperature: • • • • • • • − 10° to 35°C (50° to 95°F) at 0 to 914 m (0 to 3,000 ft) − 10° to 32°C (50° to 90°F) at 914 to 2,133 m (3,000 to 7,000 ft) • Relative Humidity: 8% to 80% • Maximum Altitude: 2,133 m (7,000 ft) • • • • • • • • • • • • • 100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 4.1 A 200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 2.1 A Input kilovolt-amperes (kVA) (approximately): − Minimum Configuration: 0.110 kVA − Maximum Configuration: 0.375 kVA Btu Output: ship configuration — 375 Btu/Hr. (110 watts) Btu Output: full configuration — 1,280 Btu/Hr. (375 watts) Noise Level: Horizontal floor standing position — 6.1 Bels (operating) • • • • • • • • • 5187 NAS Engine Model 5RZ is intended for use as rack-drawer a mounted engine and is tested and designed to operate in a horizontal position. Standards: The 5187 NAS Engine Model 5RZ supports or complies with the following standards: Multi Processor Specification (MPS) 1.4. • Peripheral Component Interconnect (PCI) specification 2.1. • Hardware-enabled to meet the International Organization for Standardization (ISO) 9241, Part 3. 101-171 UL Standard 1950 CSA (Canada) IEC950/EN60950 (CF-Europe) TUV (Germany) 5191 NAS RAID Storage Controller Model 2RU Note: The noise emission level stated is the declared (upper limit) sound power level, in Bels, for a random sample of machines. All measurements made in accordance with ISO 7779 and reported in conformance with ISO 9296. • FCC A CISPR22 Class A EN55022 Class A EMEA EN61000-3-2 EMEA EN61000-3-3 VCCI Class A ITE Taiwan BCIQ Product Safety/Country Testing/Certification Electrical (per engine) • • • Temperature: − Operating: 10° to 40°C (50° to 104°F) − Non operating: -35° to 65°C (-31° to 149°F) Relative Humidity: 5 to 80% non-condensing at 40°C Altitude: Up to 3,000 m (9,800 ft) Shock: 4g, 11 ms, half sine Vibration: − Operating: 5, 5-500 Hz at 1.0 octave/minute − Non operating: 10, 5-500 Hz at 1.0 octave/minute Power: Supported power range: 100 to 240 V ac, 47 to 63 Hz Temperature: − 10° to 35°C (50° to 95°F) at 0 to 914 m (0 to 3,000 ft) − 10° to 32°C (50° to 90°F) at 914 to 2,133 m (3,000 to 7,000 ft) Relative Humidity: 8 to 80% Wet Bulb (Power on, Power off, Storage): 27 C, 27 C, 29 C Electrical Power: 0.2 kVA Capacity of Exhaust: maximum 307 Btu/Hr Noise Level: 6.2 bels Leakage Current: 0.24 maximum at 110 V ac 0.44 maximum at 220 V ac Start up in Rush Current: − 12.54 Amps at 120 V ac − 25.34 Amps at 208 V ac EMC Conformance • • • • • • • • • -2- FCC A CISPR A VCCI A CE mark Taiwan BCIQ ICES-003 C-Tick EMEA EN61000-3-2 EMEA EN61000-3-3 In addition to the above listed machines, all necessary power cords, signal cables, and other features must also be specified when ordering. Product Safety/Country Testing/Certification • • • • CE Mark UL CSA/cUL TUV 5186 NAS Rack Model 36U requirements: A number of Filler Panels (#0002) must be specified with the rack sufficient to fill all vacant rack locations. The total required is equal to: nine minus the total of 5191s (RAID Controller) and 5192s (Storage Unit). The correct number of filler panels will be calculated by the configurator when ordering. 5192 NAS Storage Unit Model 1RU • Temperature: − − • • 10° to 35°C (50° to 95°F) at 0 to 914 m (0 to 3,000 ft) One 5195-325 Wiring and Labeling (#0003) must be ordered. 10° to 32°C (50° to 90°F) at 914 to 2,133 m (3,000 to 7,000 ft.) One of either Power Utility Wiring power cord features (#0101 or #0102) must be specified depending on the power requirements of the country where the 5195 NAS Model 325 is to be installed. Relative humidity: 8% to 80% Maximum Altitude: 2,133 m (7,000 ft.) • • • • • Electrical Specifications (per power supply) • • • • 90 V — 127 V 198 V — 257 V .06 kVA — .36 kVA 50/60 Hz Agency Approvals • • • • • • • • • • • • FCC — Verified to comply with Part 15 of the FCC Rules for a Class A digital device CE Mark (EN55022 Class A) C-Tick Mark (AS/NZS 3548 Class A) Canada (ICES/NMB) VCCI Class A UL 1950 CSA C22.2 Number 950 TUV/GS NEMKO Russia GOST-R NOM Taiwan (BSMI Certification/CNS13438) Hardware Requirements: IBM TotalStorage NAS 300 is completely configured and tested by IBM for ease of installation. The minimum configuration consists of: • • • • 5186 NAS Rack Model 36U Two 5187 NAS Engine Model 5RZs Two 3534 SAN FC Managed Hub Model 1RUs One 5191 NAS RAID Storage Controller Model 2RU The configuration may also, optionally, include: • • One additional 5191 NAS RAID Storage Controller Model 2RU Up to seven 5192 NAS Storage Unit Model 1RUs Before the second 5191 NAS RAID Storage Controller Model 2RU can be added to the IBM TotalStorage NAS 300 configuration, four 5192 NAS Storage Unit Model 1RUs must be added. The fifth, sixth, and seventh Storage Units may not be added until the second Controller has been added. These optional machines must be added in the following order: 1. 2. 3. 4. 5. 6. 7. 8. 5192 5192 5192 5192 5191 5192 5192 5192 NAS NAS NAS NAS NAS NAS NAS NAS • • • • • Storage Unit Model 1RU Storage Unit Model 1RU Storage Unit Model 1RU Storage Unit Model 1RU RAID Storage Controller Model 2RU Storage Unit Model 1RU Storage Unit Model 1RU Storage Unit Model 1RU -3- Power Cord Plug Type: NEMA L21-30P Line Cord Rating: 30 Amp / 250 V ac Power Source: 200-240 V ac, 30 Amp, three-phase Feature Number: 0101 Specify for countries: − Antigua − Aruba − Bahamas − Barbados − Belize − Bermuda − Bolivia − Brazil − Caicos Island − Canada − Cayman Islands − Costa Rica − Columbia − Dominican Republic − Guam − Ecuador − El Salvador − Guatemala − Haiti − Honduras − Jamaica − Japan − Mexico − Netherlands Antilles − Nicaragua − Panama − Peru − Philippines − Thailand − Taiwan − U.S. − Venezuela Power Cord Plug Type: IEC 309-3P+N+Gnd Line Cord Rating: 32 Amp / 415 V ac Power Source: 380-415 V ac, 32 Amp, three-phase Feature Number: 0102 Specify for countries: − Afghanistan − Albania − Algeria − Andorra − Angola − Armenia − Austria − Azerbaidjan − Belarus − Benin − Belgium − Bosnia − Burkina Faso 101-171 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − Burundi Cameroon Cambodia Cape Verde Central African Republic Chad Congo (Republic of) Comoros Congo (Democratic Republic of) Cote d′Ivoire (Ivory Coast) Croatia Czech Rep Dahomey Djibouti Equatorial Guinea Egypt Eritrea Estonia Ethiopia Finland France French Guyana French Polynesia Gabon Georgia Germany Greece Guadeloupe Guinea Guinea Bissau Hungary Iceland Indonesia Iran Kazakhstan Korea (South) Kyrgyzstan Laos Latvia Lebanon Lithuania Luxembourg Macedonia Madagascar Mali Martinique Mauritania Mauritus Mayotte Moldavia Monaco Mongolia Morocco Mozambique Netherlands New Caledonia Niger Nigeria Norway Poland Portugal Reunion Romania Russia Rwanda Sao Tome Saudi Arabia Senegal Serbia Slovakia Solvenia Somalia Spain Suriname 101-171 Sweden Syria Tajikistan Togo Tunisia Turkey Turkmenistan Ukraine Upper Volta USSR (C.I.S.) Uzbekistan Vanuatu Vietnam Wallia and Futuna Yugoslavia Zaire Denmark Lichtenstein Switzerland Bahrain Brunei Botswana Channel Islands Cyprus Dominica Gambia Ghana Grenada Guyana China (Hong Kong S.A.R.) Iraq Ireland Jordan Kenya Kuwait Liberia Malawi Malaysia Malta Myanmar (Burma) Nigeria Oman Qatar Seychelles Saint Kitts & Nevis Saint Lucia Saint Vincent and the Grenadines Sierra Leone Singapore Sudan Tanzania Trinidad & Tobago United Arab Emirate (Dubai) United Kingdom Yemen Zambia Zimbabwe Argentina Paraguay Uruguay China Australia Fiji New Zealand Papua New Guinea Israel Chile Italy Libya 3534 SAN FC Managed Hub Model 1RU requirements: When ordering the 3534 SAN FC Managed Hub Model 1RU for use with the IBM TotalStorage NAS 300, you must also specify the Specify feature number, 9295. -4- 5187 NAS Engine Model 5RZ requirements: IBM TotalStorage NAS 300 is accessed via an Ethernet LAN. The 5187 NAS Engine Model 5RZs must also be configured with at least one Ethernet adapter (#0005 or #0006). Cables for connecting these adapters to the LAN are not included with IBM TotalStorage NAS 300, but are to be provided by the customer. Security, Auditability, and Control Security and auditability features include: The number and type of Ethernet adapters installed in the two engines (nodes) of IBM TotalStorage NAS 300 must be identical. This restriction does not apply to any of the other optional adapters that may be ordered for and installed in the two engines. Feature number 0009 (Management Interconnect Cable) must be ordered if the Management Adapter (#0004) is ordered. Feature number 0004 should be ordered for only one of the engines that comprise IBM TotalStorage NAS 300. Feature number 0009 must be ordered for the engine for which feature number 0004 is NOT ordered. • Unattended boot mode allows the system keyboard to be locked to all entries except the password and at the same time allows other computers on the network to access the system disk drive. • A selectable boot sequence can be used to prevent unauthorized installation of software or removal of data from the diskette drive. The customer is responsible for evaluation, selection, and implementation of security features, administrative procedures, and appropriate controls in application systems and communications facilities. The maximum number of each type of feature that may be ordered and that are supported by the 5187-5RZ are: Terms and Conditions One SCSI Adapter (#0001) One Management Adapter (#0004) Four 10/100 Ethernet Adapters (#0005) Two Gigabit Ethernet Adapters (#0006) The total of all features cannot exceed four. This product is available for purchase under the terms of the IBM Customer Agreement (ICA). IBM hardware products are manufactured from new parts, or new and used parts. In some cases, the hardware product may have been previously installed. 5192 NAS Storage Unit Model 1RU requirements: A maximum of seven 5192 NAS Storage Unit Model 1RUs may be added to the configuration. If more than four Storage Units are to be added to the configuration, a second 5191 NAS RAID Storage Controller Model 2RU must also be added. Only the 36.4 GB 10K-4 FC Hot-Swap HDD is supported by IBM TotalStorage NAS 300. Regardless, IBM warranty terms apply. Volume Orders: Contact your IBM representative. IBM Credit Corporation Financing: Yes Software Requirements: Required software is preloaded on the IBM TotalStorage NAS 300. A CD-ROM containing the software is provided for customer reload, if needed. Warranty Period: System Hardware — One year For warranty and service offering information for the IBM SAN Fibre Channel Managed Hub (3534-1RU), refer to Hardware Announcement 101-122, dated April 23, 2001. Planning Information Licensing: IBM and some non-IBM programs are licensed under the terms and conditions of the IBM License Agreements that ship with the system. IBM also provides programs with this solution that come with their own license agreements. Unless expressly provided by IBM, IBM and non-IBM programs are provided “AS IS” WITHOUT WARRANTIES OF ANY KIND, INCLUDING, BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Customer Responsibilities: Power for IBM TotalStorage NAS 300 requires a dedicated circuit providing either, depending on country. • • Power-on and privileged access password functions provide controls of who has access to the data and server setup program on the server. It is a customer′s responsibility to ensure that the IBM TotalStorage NAS 300 is secure to prevent sensitive data from being removed. Feature number 0203 (Code Preload) must be ordered for each of the 5187 NAS Engine Model 5RZs ordered. • • • • • • 200-240 V ac, 30 Amp, three-phase 380-415 V ac, 32 Amp, three-phase Installation support is available from IBM Global Services. For more information call 888-426-4343. Cable Orders: Required cables are included in the ship group. These signal and power cables must be specified by feature number when ordering IBM TotalStorage NAS 300. Refer to the Hardware Requirements section for details. The customer is responsible for providing the cables necessary to connect IBM TotalStorage NAS 300 to the Ethernet LAN. Warranty Service: IBM On-Site Repair (IOR) Monday through Friday, 9 hours per day, excluding holidays, next-business-day response. Customers should call the IBM Support Center (800-426-7378). ServiceSuite and ServiceElect (formerly ESA) Maintenance: Maintenance Services (ESA): For ServiceElect (Z125-5510) and ServiceSuite (Z125-5745) Statements of Work Installability: Installation of IBM TotalStorage NAS 300 consists of uncrating, cabling, powering up the system and running the diagnostics. These installation activities can be accomplished in 30 minutes. Warranty Service Upgrade: IOR, 24 hours a day, 7 days a week, same day response. The RAID configuration which is highly variable, depending on customer requirements and choices, is not included in the above estimate. Maintenance Services • -5- Offering 1: IOR, Monday through Friday, 9 hours per 101-171 day, excluding holidays, next business day response. Customers should call ITS Service (800-426-7378). • Mid-Range System Option: Yes Eligible Type Offering 2: IOR, 24 hours a day, 7 days a week, same day response. Customers should call ITS Service (800-426-7378). IBM TotalStorage Network Attached Storage 300 Maintenance Service: Currently available maintenance services for ICA legacy contracts. The preferred go to market offerings are ServiceElect and ServiceSuite. However, ICA legacy contracts will still be available for current customers until they are withdrawn. Eligible Type • Option 2: IOR, 24 hours per day, 7 days per week, same-day response. Customers should call ITS Service (800-426-7378). 17% Discount Three-Year Five-Year System Maintenance Service Option 1: IOR, Monday through Friday, 9 hours per day, excluding holidays, next-business-day response. Customers should call ITS Service (800-426-7378). 12% Corporate Service Option: Yes Alternative Service (Warranty Service Upgrades): IOR, 24 hours a day, 7 days a week, same day response • Discount Three-Year Five-Year 12% 17% When a type of service involves the exchange of a machine part, the replacement may not be new, but will be in good working order. Rental Offering: No Field-Installable Features: Yes Model Conversions: No Usage Plan Machine: No Customer Setup: Yes IBM Hourly Service Rate Classification: Two Graduated Charges: No Educational Allowance: A reduced charge is available to qualified education customers. The educational allowance may not be added to any other discount or allowance. Charges Contact your IBM representative for charges information for this announcement. Order Now Use Priority/Reference Code: SE001 Phone: Fax: Internet: Mail: 800-IBM-CALL 800-2IBM-FAX ibm — [email protected] IBM Atlanta Sales Center Dept. SE001 P.O. Box 2690 Atlanta, GA 30301-2690 You can also contact your local IBM Business Partner or IBM representative. To identify them, call 800-IBM-4YOU. Note: Shipments will begin after the planned availability date. Trademarks ServiceSuite is a trademark of International Business Machines Corporation in the United States or other countries or both. Pentium is a trademark of Intel Corporation. Notes is a trademark of Lotus Development Corporation. Other company, product, and service names may be trademarks or service marks of others. 101-171 -6-