Transcript
Hardware Announcement February 18, 2003
IBM xSeries 205 — 2.67 or 2.8 GHz Intel Pentium 4 Uniprocessor Servers Overview
•
Predictive Failure Analysis (PFA) on HDDs
An excellent choice for cost-sensitive small business, xSeries 205 servers are easy to use and set up. These ultra-affordable uniprocessor servers are available with Intel Pentium 4 processors.
•
Preboot eXecution Environment (PXE) and support for Wake on LAN .
•
IBM Director standard with every xSeries server
Value and Performance
At Your Service
•
Powerful Intel Pentium 4 microprocessors at 2.67 or 2.8 GHz with 533 MHz FSB and 512 KB L2 cache
Valuable services, utilities, and systems-management tools to help improve productivity and get your server up and running quickly.
−
Additional choice of Intel Celeron at 1.8 GHz
•
IBM Director to manage xSeries 205 servers and other LAN assets
128 or 256 MB of PC2100 CL2.5 ECC DDR SDRAM UDIMM memory standard; 2.0 GB maximum
•
ServerGuide utilities to assist loading of many popular network operating systems
•
•
Five full-length, 32 bit/33 MHz PCI expansion slots
•
Integrated Broadcom 5702/5 Gigabit Ethernet controller
•
Integrated dual-channel ATA-100 EIDE bus mastering controllers or single-channel Ultra160 SCSI controller
•
Seven total drive bays
•
Attractively priced EIDE model standard with 40 GB 7,200 rpm or Ultra160 SCSI models with choice of either open bay hot-swap or a 36.4 GB 10,000 rpm HDD
At Your Control
At a Glance Attractively priced,the xSeries 205 delivers performance, function, and the ease of use you need to create a reliable foundation for your small business or workgroup. •
−
128 or 256 MB of PC2100 CL2.5 ECC double data rate (DDR) SDRAM UDIMM system memory; 2.0 GB 2 maximum
•
Integrated dual-channel (ATA-100) EIDE bus-mastering or single-channel Ultra160 controllers
•
Tower model with rack support through a rack conversion kit option
•
Five available PCI slots
•
Seven bays: two 5.25-inch, five 3.5-inch
Availability Date
•
Bootable 48x-20x 3 IDE CD-ROM
February 18, 2003
•
340-watt, voltage-sensing power supply and two cooling fans
•
System-management support for entry server
•
I/O ports:
•
One-year parts, one-year on-site 4 labor, limited warranty 5; optional warranty service upgrades
Key Prerequisites • • •
Monitor EIDE HDD Network operating system
− − −
Alert standard format (ASF), enabling alerts to be sent remotely to the system administrator and a corrective action sent back to the client
•
Automatic server restart (ASR) to restart server after operating system failure
•
Monitoring of memory, thermal, or voltage faults
Additional choice of Intel Celeron at 1.8 GHz
•
Manageability and serviceability features help diagnose problems quickly. •
2.67 or 2.8 GHz1 Pentium 4 with 512 KB L2 cache and 533 MHz FSB speed
−
•
Two USB Integrated Gigabit Ethernet with RJ-45 Two high-speed NS16550A software-compatible serial ports One high-speed parallel port supporting devices using SSP/EPP/ECP protocols adhering to the IEEE 1284 standard
Integrated ATI Rage XL and 4 MB video memory
This announcement is provided for your information only. For additional information, contact your IBM representative, call 800-IBM-4YOU, or visit the IBM home page at: http://www.ibm.com. IBM United States
IBM is a registered trademark of International Business Machines Corporation.
103-040
Description
Additional features include: •
System board — Supports high-speed 128 MB, 256 MB, 512 MB, and 1 GB PC2100 CL2.5 ECC DDR SDRAM UDIMM
•
33 MHz PCI bus — Streams data between processor or memory and the I/O subsystems
•
Full-duplex, Gigabit Ethernet PCI controller — Speeds network communications to LAN clients
Expansion Capacity and Standard Features The xSeries 205 server is housed in a minitower (optionally rack mountable) that can economically handle expansion. This model features: •
•
Solid-Performing Server Subsystems This uniprocessor entry server delivers solid, economical performance by coupling a 2.67 or 2.8 GHz Intel Pentium 4 processor with high-speed, PC2100 CL2.5 ECC DDR SDRAM UDIMM and ATA-100 EIDE storage or Ultra160 SCSI subsystems.
• •
The xSeries 205 server uses the Intel Core chipsets (845E) to optimize throughput from processors to memory, and to the 32-bit PCI bus.
• • •
Standard xSeries 205 Configurations Model 8480─42X 8480─4AX 8480─43X 8480─52X 8480─5AX 8480─53X 8480─94X
103-040
Processor 2.67 GHz Pent 4 2.67 GHz Pent 4 2.67 GHz Pent 4 2.8 GHz Pent 4 2.8 GHz Pent 4 2.8 GHz Pent 4 1.8 GHz Celeron
Cache 512 KB 512 KB 512 KB 512 KB 512 KB 512 KB 128 KB
Memory 256 MB 256 MB 256 MB 256 MB 256 MB 256 MB 128 MB
Interface SCSI SCSI EIDE SCSI SCSI EIDE EIDE
HDD 36.4 open 40.0 36.4 open 40.0 40.0
GB bay GB GB bay GB GB
-2-
340-watt worldwide, voltage-sensing power supply with auto restart — Supports maximum configurations and minimizes operator intervention after a temporary power outage Two full-speed fans (three on hot-swap SCSI models) plus one variable fan in the power supply that cools: − Power supply − Drive bays − Microprocessor − I/O 256 MB of PC2100 CL2.5 ECC DDR SDRAM UDIMM standard Two DIMM sockets support: − Up to 2 GB system memory − Mixing memory sizes Five full-length adapter card slots — Support multiple adapters for network or data storage One AGP slot Seven drive bays − One accessible 5.25-inch, half-high bay with 48x-20x CD-ROM drive − One open accessible 5.25/3.5-inch, half-high bay, supporting tape backup devices − Two accessible 3.5-inch, slim-high bays, one with a standard 1.44 MB diskette drive. − Three internal 3.5-inch, slim-high bays, one HDD standard on some models.
•
•
•
EIDE models include: − Dual integrated ATA-100 EIDE controllers — Supporting up to two additional EIDE devices − 40 GB ATA-100 EIDE HDD (100 MB/s maximum date transfer) SCSI models include: − Single-channel Ultra160 SCSI with five-drop LVD SCSI cabling with active termination for installing 16-bit internal SCSI devices − Support for 15,000 rpm Ultra160 SCSI HDDs (160 MB/s maximum data transfer) Integrated ATI video with 4 MB of video memory
•
•
Systems Management and Control xSeries 205 servers comply with the 2000 uATX implementation guidelines. These guidelines offer better control and manageability of their network. Supported features include: • • • • • •
• • • •
• •
Wake on LAN, for legacy LAN adapters to remotely turn the server on from an off state Wake on LAN and ASF supported on integrated Ethernet controller ASF support legacy LAN adapters with this function Flash EPROM write protection Gated RESET for power management SMBus isolation isolates one bus section and required system components during system power-down from other buses and components to prevent current leakage into devices without power PXE support SM BIOS MAC address on PC box Remote Deployment Manager
•
• • • • • •
The xSeries 205 server comes with a number of tools and programs designed to make ownership a positive experience. From the start, IBM has programs to help you purchase, get your server running, and keep it running smoothly. IBM can help your company maintain ownership of technology leadership servers.
Reduced downtime Increased productivity of IT personnel and end users Reduced service and support costs
IBM Director includes a portfolio of integrated server tools that works with the Remote Supervisor Adapter or other systems management monitoring functions. Typical functions and monitoring capabilities can include: PFA-enabled critical hardware components Temperature Voltage Fan speed Diagnostic LEDs
• • • •
•
The ServerProven 6 program lets you confidently configure your server with various devices and operating systems. This Web-based program provides compatibility information from actual testing of the xSeries 205 server with various adapters and devices.
•
The ServerGuide CD library includes online publications, utilities, and drivers that assist you in loading of popular network operating systems.
Product Positioning The xSeries 205 server is positioned as the flexible, small-business, entry server platform of the xSeries universal server line. It is designed and packaged with features intended specifically for cost-conscious small and medium businesses.
IT administrators achieve comprehensive, virtual on-site control of xSeries servers through the ability to remotely: • •
Tivoli Enterprise and Tivoli NetView Computer Associates CA Unicenter TNG HP OpenView Microsoft SMS BMC Patrol NetlQ
World-Class Support Tools and Programs
IT administrators can view the hardware configuration of remote systems in detail and monitor the usage and performance of critical components such as processors, HDDs, and memory.
• • • • •
Operating system load POST time-out Voltage Temperature Set proactive alerts for critical server events including PFA on: − Processors − VRMs − Memory − Fans − Power supplies − HDDs Define automated actions such as: − Send an e-mail or page to an administrator − Execute a command or program − Pop up an error message to the IBM Director console Flash BIOS Monitor and graph the use of server resources such as: − Memory − Processor − HDDs Identify potential performance bottlenecks and react to prevent downtime
IBM Director Agent provides integration into leading workgroup and enterprise systems management environments, via upward integration modules (available from IBM and third parties). Advanced management capabilities built into xSeries servers are available through:
The xSeries 205 server also features IBM Director, a powerful, highly integrated, systems management software solution built on industry standards and designed for ease of use. Exploit your existing enterprise or workgroup management environments and use the Internet to securely access and manage physically dispersed IT assets more efficiently. It can help reduce costs through: • • •
− − − −
Access the server regardless of its status Inventory and display detailed system and component information View server bootup during POST Browse and delete logs of events and errors Reset or power cycle the server Monitor and set thresholds on server health including:
The xSeries 205 server combines leading industry-standard technologies, excellent internal data storage capacity, ease of use, and basic systems management and control features, into an attractively priced entry server. This uniprocessor server provides solid performance to support general-purpose network or Web-serving applications.
-3-
103-040
The server is configured with choices that span a broad price range. It has the features and the price points that are perfect for small and medium businesses.
Reference Information 1
2
3 4
5
GHz denotes the internal and/or external clock speed of the microprocessor only, not application performance. Many factors affect application performance. When referring to HDD or tape backup capacity, GB stands for one billion bytes. Total user capacity may vary depending on operating environments. Actual playback speed will vary and is often less than the maximum possible. You may be asked certain diagnostic questions before a technician is sent. For information on the IBM Statement of Limited Warranty, visit:
http://www.ibm.com/servers/ support/machine_warranties/ Call 800-772-2227 or contact your IBM representative or reseller. Copies are available upon request. 6
IBM makes no warranties, expressed or implied, regarding non-IBM products and services that are ServerProven, including but not limited to implied warranties of merchantability and fitness for a particular purpose. These products are offered and warranted solely by third parties.
Trademarks The e-business logo, xSeries, and ServerGuide are trademarks of International Business Machines Corporation in the United States or other countries or both. Predictive Failure Analysis, Wake on LAN, NetView, and ServerProven are registered trademarks of International Business Machines Corporation in the United States or other countries or both. Intel, Pentium, and Celeron are registered trademarks of Intel Corporation. Microsoft is a trademark of Microsoft Corporation. Tivoli is a registered trademark of International Business Machines Corporation or Tivoli Systems Inc. in the United States or other countries or both. Other company, product, and service names may be trademarks or service marks of others.
103-040
-4-
IBM US Announcement Supplemental Information February 18, 2003
Publications The following publications and CD-ROMs are shipped with the xSeries 205 server. •
The xSeries 205 Installation Guide contains an introduction to the computer, installation and setup, installing options, reference information, and problem determination. The installation guide has easy-to-use text and pictorials to enable users to quickly set up the server.
•
ServerGuide contains online publications and drivers to support the xSeries 205. In addition, it includes a set of easy-to-use utilities that provides assisted installation via CD of several popular network operating systems.
•
IBM Director included.
systems
management
software
is
Note: Software versions, features, and functions shipped with this system may change as new releases become available or may be discontinued at any time.
The xSeries 205 Installation Guide and Hardware Maintenance Manual , in U.S. English versions, are available from:
Tape backup Total Bays 5.25/3.5 in half-high (HH) 3.5 in slim Hot-swap Internal capacity Bays available 5.25/3.5 in HH 3.5 in slim Hot-swap Total slots PCI (33 MHz) 64-bit 32-bit AGP slot Slots available Management proc. Ethernet Controller CD-ROM (IDE) Diskette drive Power supply Number standard Hot-swap Redundant power Auto restart
8480-42X
8480-4AX
No 7 2
No 7 2
5 0 293 GB7 4 18 3 0 6 5 0 5 1 6 No 1 GB 48x-20x 1.44 MB 340 W 1 No No Yes
2 3 220 GB7 5 18 1 3 6 5 0 5 1 6 No 1 GB 48x-20x 1.44 MB 340 W 1 No No Yes
8480-43X
8480-52X
Pentium 4 2.67 GHz 100/400 MHz 1 1 512 KB
Pentium 4 2.8 GHz 133/533 MHz 1 1 512 KB
256 MB ECC
256 MB ECC
1x256 MB 2 2.0 GB SVGA, ATI 4 MB 0 0 0 0 EIDE ATA/100 2 2 0 40 GB EIDE No 7 2
1x256 MB 2 2.0 GB SVGA, ATI 4 MB Ultra-160 SCSI 1 1 0 EIDE ATA/100 2 2 0 36.4 GB No 7 2
5 0 240 GB7
5 0 293 GB7
http://www.ibm.com/pc/support
Technical Information Physical Specifications: xSeries 205
Processor Internal speed External speed Number standard Maximum L2 cache (full-speed) Memory (133 MHz SDRAM) DIMMs DIMM sockets Capacity Video controller Memory SCSI controllers Channels Connector internal Connector external IDE controllers Channels Connector internal Connector external Fixed disk
8480-42X
8480-4AX
Pentium 4 2.67 GHz 100/400 MHz 1 1 512 KB
Pentium 4 2.67 GHz 100/400 MHz 1 1 512 KB
256 MB ECC
256 MB ECC
1x256 MB 2 2.0 GB SVGA, ATI 4 MB Ultra-160 SCSI 1 1 0 EIDE ATA/100 2 2 0 36.4 GB
1x256 MB 2 2.0 GB SVGA, ATI 4 MB Ultra-160 SCSI 1 1 0 EIDE ATA/100 2 2 0 0 GB
Processor Internal speed External speed Number standard Maximum L2 cache (full-speed) Memory (133 MHz SDRAM) DIMMs DIMM sockets Capacity Video controller Memory SCSI controllers Channels Connector internal Connector external IDE controllers Channels Connector internal Connector external Fixed disk Tape backup Total Bays 5.25/3.5 in half-high (HH) 3.5 in slim Hot-swap Internal capacity
This announcement is provided for your information only. For additional information, contact your IBM representative, call 800-IBM-4YOU, or visit the IBM home page at: http://www.ibm.com. IBM United States
IBM is a registered trademark of International Business Machines Corporation.
103-040
Bays available 5.25/3.5 in HH 3.5 in slim Hot-swap Total slots PCI (33 MHz) 64-bit 32-bit AGP slot Slots available Management proc. Ethernet Controller CD-ROM (IDE) Diskette drive Power supply Number standard Hot-swap Redundant power Auto restart
Processor Internal speed External speed Number standard Maximum L2 cache (full-speed) Memory (133 MHz SDRAM) DIMMs DIMM sockets Capacity Video controller Memory SCSI controllers Channels Connector internal Connector external IDE controllers Channels Connector internal Connector external Fixed disk Tape backup Total bays 5.25/3.5 in HH 3.5 in slim Hot-swap Internal capacity Bays Available 5.25/3.5 in HH 3.5 in slim Hot-swap Total slots PCI (33 MHz) 64-bit 32-bit AGP slot Slots available Management proc. Ethernet controller CD-ROM (IDE) Diskette drive Power supply Number standard Hot-swap Redundant power Auto restart
103-040
8480-43X
8480-52X
4 18 3 0 6 5 0 5 1 6 No 1 GB 48x-20x 1.44 MB 340 W 1 No No Yes
4 18 3 0 6 5 0 5 1 6 No 1 GB 48x-20x 1.44 MB 340 W 1 No No Yes
8480-5AX
8480-53X
Pentium 4 2.8 GHz 133/533 MHz 1 1 512 KB
Pentium 4 2.8 GHz 133/533 MHz 1 1 512 KB
256 MB ECC
256 MB ECC
1x256 MB 2 2.0 GB SVGA, ATI 4 MB Ultra-160 SCSI 1 1 0 EIDE ATA/100 2 2 0 0 GB No 7 2 2 3 220 GB7 5 18 1 3 6 5 0 5 1 6 No 1 GB 48x-20x 1.44 MB 340 W 1 No No Yes
1x256 MB 2 2.0 GB SVGA, ATI 4 MB 0 0 1 0 EIDE ATA/100 2 2 0 40 GB EIDE No 7 2 5 0 240 GB7 4 18 3 0 6 5 0 5 1 6 No 1 GB 48x-20x 1.44 MB 340 W 1 No No Yes
8480-94X
Processor Internal speed External speed Number standard Maximum L2 cache (full-speed) Memory (133 MHz SDRAM) DIMM sockets Capacity Video controller Memory SCSI controllers Channels Connector internal Connector external IDE controllers Channels Connector internal Connector external Fixed disk Tape backup Total bays 5.25/3.5 in HH 3.5 in slim Hot-swap Internal capacity Bays Available 5.25/3.5 in HH 3.5 in slim Hot-swap Total slots PCI (33 MHz) 64-bit 32-bit AGP slot Slots available Management proc. Ethernet controller CD-ROM (IDE) Diskette drive Power supply Number standard Hot-swap Redundant power Auto restart 7
8
Celeron 1.8 GHz 100/400 MHz 1 1 128 KB 128 MB ECC 1x128 MB 2 2.0 GB SVGA, ATI 4 MB 0 0 0 0 EIDE ATA/100 2 2 0 40 GB No 7 2 5 0 240 GB7 4 18 3 0 6 5 0 5 1 6 No 1 GB 48x-20x 1.44 MB 340 W 1 No No Yes
Capacities are based on installation of three 80 GB slim-line EIDE HDDs or four 73.4 GB SCSI HDDs. For the most up-to-date information on supported HDD options, visit:
http://www.ibm.com/pc/us/compat This bay does not support HDD options. It can be used for removable media devices such as tape backup.
SCSI HDD Characteristics
• • • • • • • • •
36.4 GB9 HDD Formatted capacity: 36,400 million bytes Average read seek time: 5.2 ms Burst transfer rate (maximum): 160.0 MB/s Average latency: 3.0 ms Drive rotation speed (rpm): 10,000 rpm Sustained data transfer rate: 21 to 35 MB/s PFA/S.M.A.R.T. enabled: Yes Interface: Ultra160 SCSI
EIDE HDD Characteristics
• • • • •
-2-
40 GB9 HDD Formatted capacity: 40,000 million bytes Average read seek time: <9.0 ms Burst transfer rate (maximum): 100.0 MB/s Average latency: 4.2 ms
• • • • 9
•
Drive rotation speed (rpm): 7200 rpm Sustained data transfer rate: 18 to 36 MB/s PFA/S.M.A.R.T enabled: Yes Interface: Ultra ATA/100
Minimum Clearance for Cooling
• •
GB equals 1,000,000,000 bytes when referring to HDD capacity. Actual user accessible capacity may vary slightly based on operating environments.
• • • 10
Formatted capacity: 650 MB Average access time including latency: Less than 85 ms Sustained data transfer rate: 3000 to 7200 KB/s Burst data transfer rate − ATA PIO Mode 4: 16.6 MB/sec − ATA Multi-Word DMA Mode 2: 16.6 MB/sec Technology: Full constant angular velocity (CAV)
•
100-127 (nominal) V ac; 50-60 Hz; 8.0 A (maximum)
•
200-240 (nominal) V ac; 50-60 Hz; 4.0 A (maximum)
•
Input kilovolt-amperes (kVA) (approximately): − −
48x-20x CD-ROM variable read rate. Actual playback speed will vary and is often less than the maximum possible.
• • •
ATI Rage XL Graphics Controller chip Integrated on planar and connected to the PCI bus 4 MB SDRAM standard/maximum video memory 128-bit graphics engine with 8, 16, and 32 bpp mode acceleration 32 bpp (4G colors/True Color) support Integrated 300 MHz RAMDAC DDC2B monitor communications support
Btu output: ship configuration — 350 Btu/hr (102 watts)
•
Btu output: full configuration — 550 Btu/hr (161 watts)
•
Wet bulb: (caloric value) — 1604 Btu/hr (maximum configuration)
•
Acoustical noise emission level: Sound power levels − −
Microsoft Windows NT V4.0, Windows 2000 and Linux Colors
Refresh Rate (Hz)
640 x 480 x 8 640 x 480 x 16 640 x 480 x 24 640 x 480 x 32 800 x 600 x 8 800 x 600 x 16 800 x 600 x 24 800 x 600 x 32 1024 x 768 x 8 1024 x 768 x 16 1024 x 768 x 24 1024 x 768 x 32 1280 x 1024 x 8 1280 x 1024 x 16 1280 x 1024 x 24 1280 x 1024 x 32 1600 x 1200 x 8 1600 x 1200 x 16 1600 x 1200 x 24 1600 x 1200 x 32
256 64K 16M 4G 256 64K 16M 4G 256 64K 16M 4G 256 64K 16M 4G 256 64K 16M 4G
60, 60, 60, 60, 60, 60, 60, 60, 60, 60, 60, 60, 43, 43, 43, 43, 60, 60, 60, 60,
72, 72, 72, 72, 70, 70, 70, 70, 72, 72, 72, 72, 60, 60 60, 60, 66, 66, 66, 66
75, 75, 75, 75, 75, 75, 75, 75, 75, 75, 75, 75, 70,
90, 90, 90, 90, 90, 90, 90, 90, 90, 90, 90, 90, 72
70, 70, 76, 76, 76,
72 72 85 85 85
The xSeries 205 is shipped for use as a floor-standing server. An optional 4Ux24D Tower-to-Rack Kit allows rack mounting. Only with this conversion kit is this server supported in a horizontal orientation. Standards: These systems support or comply with the following standards:
100 100 100 100 100 100 100 100 100 100 100 100
For optimum operation when chaining, it is suggested that resolutions no larger than 1024 x 768 x 32 be used
•
Some modes are not supported by all monitors
•
Peripheral Component Interconnect (PCI) specification 2.1.
•
This model is ISO 9241 capable. declaration is available.
•
FCC — Verified to comply with Part 15 of the FCC Rules, Class A
•
Canada ICES-003, issue 3, Class A
•
UL 195011
•
CSA C22.2 No. 950
•
NOM-01811
11
This xSeries server is certified by the respective UL and NOM agencies.
Operating Environment
•
Temperature: − −
Dimensions
• • •
A supplier′s
Equipment Approvals and Safety
Notes:
•
5.1 bels (idling) 5.3 bels (operating)
Note: The noise emission level stated is the declared (upper limit) sound power level, in bels, for a random sample of machines, typically configured, and operating in idle mode; for example, powered on, but no disk drive read/write or other I/O activity. All measurements made in accordance with ANSI S12.10 and ISO 7779, and reported in accordance with ISO 9296.
Supported video mode capabilities for the SVGA PCI controller:
Resolution
Minimum configuration: 0.095 kVA Maximum configuration: 0.213 kVA
•
Video Subsystem
• • • •
100 mm (4 in) at the back 50 mm (2 in) on each side
Electrical
48x-20x10 CD-ROM Drive Characteristics
• •
Weight: (minimum ship configuration) 15.9 kg (35.0 lb) (maximum ship configuration) 19.1 kg (42.0 lb)
Width: 165 mm (6.5 in) Depth: 508 mm (20.0 in) Height: 470 mm (18.5 in)
-3-
10.0° to 35.0°C (50° to 95°F) at 0 to 914 m (0 to 3,000 ft) 10.0° to 32.0°C (50° to 90°F) at 914 to 2,133 m (3,000 to 7,000 ft)
•
Relative humidity: 8% to 80%
•
Maximum altitude: 2,133 m (7,000 ft)
103-040
Hardware Requirements: For attended installation of an operating system, this server requires a compatible:
Limitations
•
The xSeries 205 server supports a maximum of 2.0 GB of system memory when you add a 1 GB PC2100 CL2.5 ECC DDR SDRAM UDIMM in each of the two DIMM slots. All supported system memory is addressable through direct memory access (DMA). This server supports 256 MB, 512 MB, and 1 GB PC2100 CL2.5 ECC DDR SDRAM UDIMM. All supported DIMMs can coexist in the same system. Refer to the Planning Information section or our compatibility Web page for supported memory options.
•
Wake-on-LAN is not supported if systems are improperly shut down.
•
The open 5.25-inch bay supports removable media devices, such as tape backup devices. It does not support HDD options.
•
When having the unit serviced, plan to have these components attached to your server either directly or indirectly via a console switch.
Use the version of ServerGuide that ships with the system, or a later version, to load software and drivers. Earlier versions of ServerGuide may not be compatible with the server.
Software Requirements: The following network operating systems are supported in the xSeries 205:
Refer to the Software Requirements section for operating system limitations.
• • • •
Keyboard Mouse HDD Display
Unattended or remote installation may be performed without requiring some or all of these components. Review your unattended software installation program information for specific hardware configuration requirements. For service, the server requires a compatible: • • • •
•
Keyboard Mouse HDD Display
Microsoft: − − −
Planning Information 12
Windows 2000 Server Windows 2000 Advanced Server12 Windows Small Business Server
Customer Responsibilities: xSeries 205 Customer Setup
•
Novell: NetWare 6.012
The xSeries 205 server is designated as customer setup. Customer setup instructions are shipped with systems.
•
Linux
Standard EIDE Configurations
− −
The following network operating systems are supported as preloads in the xSeries 205:
In xSeries 205 models using the EIDE interface for storage device attachment, a two-drop cable is used to attach the standard 40.0 GB EIDE HDD to one of the EIDE connectors. A second EIDE controller provides the interface for the IDE CD-ROM drive. A two-drop IDE cable connects the IDE controller to the IDE CD-ROM. Up to two additional EIDE or IDE devices can be installed (one off each controller).
•
Microsoft:
Standard SCSI Configurations
− −
xSeries 205 models with a SCSI adapter are cabled internally with a five-drop, 16-bit wide LVD SCSI cable with a built-in active terminator at one end of the cable. The other end of the cable is attached to the internal 68-pin connector of the standard Ultra160 SCSI adapter. SCSI devices can be connected to any of the five cable connectors.
• 12
Red Hat 7.3 SuSE 8.012
12
IBM: 4690 Operating System12 Certification is planned for these network operating systems
Windows 2000 Server Windows 2000 Advanced Server
Note: For additional support, certification, and version information on network operating systems, visit: http://www.ibm.com/pc/us/compat
Compatibility: The xSeries 205 systems contain licensed system programs that include set configuration, set features, and test programs. System BIOS (flash BIOS modified to IBM specifications) is loaded from a “flash” EEPROM into system memory. This BIOS provides instructions and interfaces designed to support the standard features of the server and to maintain compatibility with many current software programs.
Supported Memory Options
To view detailed information on the Internet about IBM and non-IBM devices, adapters, software, and network operating systems supported with xSeries servers, visit:
The following memory options are supported: IBM 256 MB PC2100 CL2.5 ECC DDR SDRAM UDIMM (10K0067)
•
IBM 512 MB PC2100 CL2.5 ECC DDR SDRAM UDIMM (10K0069)
•
IBM 1 GB PC2100 CL2.5 ECC DDR SDRAM UDIMM (10K0071)
Rack Installations
http://www.pc.ibm.com/us/compat
The xSeries 205 server can be converted to a rack-mounted unit by installing a 4Ux24D Tower-to-Rack Kit. The 4U xSeries 205 can be installed in a 19-inch industry-standard rack such as:
Contact your IBM representative, IBM Business Partner, or refer to the IBM Sales Manual for information on the compatibility of hardware and software for xSeries servers. The Sales Manual is updated periodically as new features and options are announced that support these servers.
103-040
•
• • •
-4-
NetBAY42 ER Cabinet NetBAY42 SR Cabinet NetBAY25 SR Cabinet
If using a non-IBM rack, the cabinet must meet the EIA-310-D standards with a depth of at least 28 inches. Also, adequate space (approximately two inches for the front bezel and one inch for air flow) must be maintained from the slide assembly to the front door of the rack cabinet to allow sufficient space for the door to close and provide adequate air flow.
Terms and Conditions This product is available for purchase under the terms of the IBM Customer Agreement (ICA). IBM hardware products are manufactured from new parts, or new and used parts. In some cases, the hardware product may have been previously installed.
Cable Orders: The Gigabit full duplex, Ethernet PCI controller, standard with the server, is connected directly to a RJ-45 connector. The RJ-45 connector provides a 10/100/1000Base-T interface for connecting twisted-pair cable to the Ethernet network. Cabling is not included with the server. To connect the Ethernet controller to a repeater or switch, use an unshielded twisted pair (UTP) cable with RJ-45 connectors at both ends. For 100/1000 Mbps operation, Category 5 cabling must be used. For 10 Mbps operation, Category 3, or better, cabling must be used.
Regardless, IBM warranty terms apply. IBM Credit Corporation Financing: Yes
To obtain copies of the IBM Statement of Limited Warranty, contact your reseller or call IBM. In the United States, call 800-772-2227. In Canada, call 800-565-3344. Warranty Period
•
There are no additional cabling requirements, other than for system power, keyboard, mouse, and monitor connections.
Warranty Service: System hardware
IOR, 9 hours a day, Monday through Friday excluding holidays, next-business-day response
Installability: The xSeries 205 system requires about 20 minutes for installation. Installation includes unpacking, setting up, and powering on the system. Additional time is required to install an operating system, additional adapters, or features.
Optional features: Optional IBM features initially installed with an xSeries server carry the same warranty as the system. If installed after the initial system installation, they carry the balance of the system warranty or the optional feature warranty, whichever is greater.
Packaging: xSeries 205
• •
System unit carton − System unit Country kit carton − Keyboard with attached cable − Two-button mouse with attached cable − System unit power cord − xSeries 205 Installation Guide − ServerGuide and IBM Director
Call 800-IBM-SERV (426-7378) in the U.S. to assist with problem isolation for hardware to determine if warranty service or parts exchange is required. Some parts of the system, such as the keyboard, mouse, and memory, are considered customer replaceable units. International Warranty Service (IWS): IWS is available during the warranty period to customers who travel or relocate to countries where their computer is sold and serviced by IBM or IBM resellers authorized to perform warranty service. Eligible IBM computers are identified by their four-digit machine type.
The xSeries 205 system is shipped as a single package. The country kit carton is contained inside the top portion of the system unit carton.
Security, Auditability, and Control
You can obtain IWS through the method of service, such as depot, carry-in or on-site, provided in the servicing country. Service methods and procedures vary by country, and some service or parts may not be available in all countries. Service centers in certain countries may not be able to service all models of a particular machine type. In addition, some countries may have fees and restrictions that apply at the time of service.
Security and auditability features include: •
Power-on password (secured boot).
•
A mechanical lock allowing the user to lock the system cover to prevent unauthorized personnel access to internal components of the server.
•
Selectable boot sequence preventing unauthorized installation of software or removal of data from the diskette drive.
•
Tie-down capability by utilizing a common U bolt attached to the back frame.
•
Operation without a keyboard and display are supported after the server is configured with the appropriate network operating system. This minimizes the risk of unauthorized people tampering with the system software and configuration.
System hardware — One year on parts and labor
To determine the eligibility of your computer and to view a list of countries where service is available, visit: http://www.pc.ibm.com/support
Click on the Warranty Lookup tab. For more information on IWS, refer to Services Announcement 601-034, dated September 25, 2001. Licensing: Programs included with this product are licensed under the terms and conditions of the License Agreements that are shipped with the system.
The customer is responsible for evaluation, selection, and implementation of security features, administrative procedures, and appropriate controls in application systems and communications facilities.
-5-
103-040
Corporate Service Option: The 8480 is an eligible machine for the Corporate Service Option of the ICA.
Maintenance Services ServiceElect and ServiceSuite : ServiceElect and ServiceSuite provide hardware warranty service upgrades, maintenance, and selected annuity support services in one agreement.
Eligible Type
Warranty Service Upgrade: During the warranty period, warranty service upgrade provides an enhanced level of service for an additional charge. This enhanced level of service includes a higher level of on-site service labor during the original warranty period.
Extended Maintenance Option: No
Network System
IOR, 9 hours a day, Monday through Friday excluding holidays, 4-hour average response
•
IOR, 24 hours a day, 7 days a week, 4-hour average response
•
IOR, 24 hours a day, 7 days a week, 2-hour average response
IOR, 9 hours a day, Monday through Friday excluding holidays, next-business-day response
•
IOR, 9 hours a day, Monday through Friday excluding holidays, 4-hour average response
•
IOR, 24 hours a day, 7 days a week, 4-hour average response
•
IOR, 24 hours a day, 7 days a week, 2-hour average response
Warranty Service: IBM is now shipping machines with selected non-IBM parts that contain an IBM field replaceable unit (FRU) part number label. These parts are to be serviced during the IBM machine warranty period. IBM is covering the service on these selected non-IBM parts as an accommodation to their customers, and normal warranty service procedures for the IBM machine apply. Warranty Service Upgrades and Maintenance Services: Under certain conditions, IBM Integrated Technology Services repairs selected non-IBM parts at no additional charge for machines that are covered under a warranty service upgrade or maintenance services.
IBM Service provides hardware problem determination on non-IBM parts (adapter cards, PCMCIA cards, disk drives, memory, and so forth) installed within IBM systems covered under warranty service upgrade or maintenance services and provides the labor to replace the failing parts at no additional charge. If IBM has Technical Service Agreements with the manufacturers of the failing part, or if the failing part is an accommodations part (a part with an IBM FRU label), IBM may also source and replace the failing parts at no additional charge. For all other non-IBM parts, customers are responsible for sourcing the parts. Installation labor is provided at no additional charge, if the machine is covered under a warranty service upgrade or maintenance services.
Maintenance Service (ICA): Maintenance services are available for ICA legacy contracts. The preferred go-to-market offerings are ServiceElect. However, ICA legacy contracts will still be available for current customers until they are withdrawn. Alternative Service (Warranty Service Upgrades): During the warranty period, warranty service upgrade provides an enhanced level of service for an additional charge.
The following available.
warranty
service
upgrade
option
IBM Hourly Service Rate Classification: One
is
ServicePac Offerings
IOR, 24 hours a day, 7 days a week, 4-hour average response
Warranty and Maintenance Options: The announced products may be eligible for ServicePacs for Warranty and Maintenance Options, convenient prepackaged offerings for warranty service upgrades and maintenance services.
Maintenance Service
•
IOR, 9 hours a day, Monday through Friday excluding holidays, next-business-day response
•
IOR, 24 hours a day, 7 days a week, 4-hour average response
Installation Services: The announced products may be eligible for ServicePacs for Installation Services, convenient prepackaged offerings for installation services. Refer to the Prices section for information on the availability of ServicePac offerings.
Mid-Range System Option: The xSeries 205 is an eligible machine for the Mid-Range System Option of the ICA. Eligible Type
8480
For additional ServicePac information, visit: http://www-1.ibm.com/services/its/ us/servicepac.html
Discount Three-Year Five-Year
17%
30% 22%
Non-IBM Parts Support
Maintenance Service
•
25% 17%
Central Facility Maintenance Service (CFMS) Option: No
The following warranty service upgrade options are available. •
Discount Three-Year Five-Year
Rental Offering: No
22%
Field-Installable Features: Yes Model Conversions: No Machine Installation: Customer setup. Customers are responsible for installation according to the instructions IBM provides with the machine.
103-040
-6-
Graduated Charges: No
Maintenance Service (Legacy) Charges Alternative Service (Warranty Service Upgrades)
Prices
Description
xSeries 205 2.67 GHz Pentium 4 256 MB, 36.4 GB SCSI HDD xSeries 205 2.67 GHz Pentium 4 256 MB, Open Bay, Hot-Swap xSeries 205 2.67 GHz Pentium 4 256 MB, 40 GB EIDE HDD xSeries 205 2.8 GHz Pentium 4 256 MB, 36.4 GB SCSI HDD xSeries 205 2.8 GHz Pentium 4 256 MB, Open Bay, Hot-Swap xSeries 205 2.8 GHz Pentium 4 256 MB, 40 GB EIDE HDD xSeries 205 1.8 GHz Celeron 128 MB, 40 GB EIDE HDD 13
Machine Type/ Model
Part Number
8480-42X
848042X
IBM List Price13
Machine Type
IOR 24 x 7 4-hour
8480-4xX
$200
$1,165 Maintenance Service
8480-4AX 8480-43X
84804AX 848043X
1,115 Machine Type
IOR 9x5
IOR 24 x 7 4-Hour
8480-4xX
$840
$1,260
1,005
8480-52X
848052X
1,475
For ServiceElect (ESA) Maintenance Service Charges, contact IBM Global Services at 888-IBM-4343 (426-4343).
8480-5AX
84805AX
1,375
Global Financing
8480-53X
848053X
1,265
8480-94X
848094X
499
IBM Global Financing offers competitive financing to credit-qualified customers and Business Partners to assist them in acquiring IT solutions. Offerings include financing for IT acquisition, including hardware, software, and services, both from IBM and other manufacturers or vendors, as well as commercial financing (revolving lines of credit, terms loans, acquisition facilities, and inventory financing credit lines) for Business Partners. Offerings (for all customer segments: small, medium, and large enterprise), rates, terms, and availability can vary by country. Contact your local IBM Global Financing organization or visit the Web at:
IBM List Price does not include tax or shipping and is subject to change without notice. Reseller prices may vary.
To order direct, call IBM at 877-999-7115 and select option 4. For the name of the nearest IBM representative or Business Partner, call 800-IBM-4YOU (426-4968).
http://www.ibm.com/financing Trademarks
ServicePac for Warranty and Maintenance Description
1-year MA IOR 24 x 7 2-hour average response 1-year MA IOR 24 X 7 4-hour average response 1-year MA IOR 9 x 5 4-hour average response 1-year MA IOR 9 x 5 NBD response 3-year IOR 24 x 7 2-hour average response 3-year IOR 24 x 7 4-hour average response 3-year IOR 9 x 5 4-hour response 3-year IOR 9 x 5 NBD response
xSeries, ServerGuide, and ServiceSuite are trademarks of International Business Machines Corporation in the United States or other countries or both. Wake-on-LAN and ServicePac are registered trademarks of International Business Machines Corporation in the United States or other countries or both. Pentium and Celeron are registered trademarks of Intel Corporation. Microsoft is a trademark of Microsoft Corporation. Windows and Windows NT are registered trademarks of Microsoft Corporation. Other company, product, and service names may be trademarks or service marks of others.
ServicePac Part Number
69P9385 69P9384 69P9383 69P9382 69P9512 69P9511 69P9510 69P9509
For ServicePac prices, visit: http://www-1.ibm.com/services/its/us/spwarmain.html
-7-
103-040