Preview only show first 10 pages with watermark. For full document please download

Idec Ry2p-u Catalogue

   EMBED


Share

Transcript

Relays RY/RM Series RY/RM Series — General Purpose Miniature Relays Key features of the RY series include: • Compact miniature size saves space • 2PDT and 4PDT models, available with bifurcated crossbar contacts, ensure reliable low-current switching for dry circuit applications • Choice of plug-in/solder or PCB type terminals • Options include check button for test operation and indicator lights • DIN rail, surface, panel, and PCB type sockets available for a wide range of mounting applications Specifications Relays E Contact Material RY2, RY4: Silver (Ag), gold-plated RY22, RY42: Ag-Pd alloy RM: Silver (Ag) Contact Resistance RY2, RY4: 50mΩ maximum RY22, RY42: 100mΩ maximum RM: 30mΩ maximum Minimum Applicable Load RY2, RY4: 5V DC, 10mA/24V DC, 5mA RM2: 24VDC/10mA, 5VDC/20mA (reference value) Bifurcated contacts: RY22, RY42: 1V DC, 100µA (reference value) Operating Time 20ms maximum Release Time 20ms maximum Maximum Continuous Applied Voltage (AC/DC) at 20°C 110% of the rated voltage Minimum Operating Voltage (AC/DC) at 20°C 80% of the rated voltage Drop-Out Voltage (AC) 30% or more of the rated voltage Drop-Out Voltage (DC) 10% or more of the rated voltage Power Consumption RY2, RY22: DC: approximately 0.8W AC: approximately 1.1VA (50Hz), 1VA (60Hz) RY4, RY42, RM2: DC: approximately 0.9W AC: approximately 1.4VA (50Hz), 1.2VA (60Hz) Insulation Resistance 100MΩ minimum (measured with 500V DC megger) Dielectric Strength RY2, RY22: Between live and dead parts: 1,500V AC, 1 minute; Between contact and coil: 1,500V AC, 1 minute; Between contacts of different poles: 1,500V AC, 1 minute; Between contacts of the same pole: 1,000V AC, 1 minute RY4, RY42, RM2,: Between live and dead parts: 2,000V AC, 1 minute; Between contact and coil: 2,000V AC, 1 minute; Between contacts of different poles: 2,000V AC, 1 minute; Between contacts of the same pole: 1,000V AC, 1 minute CSA Certified File No.LR35144 UL Recognized File No. E55996 File No. B020813332452 Frequency Response 1,800 operations/hour Temperature Rise Coil: 85°C maximum Contact: 65°C maximum Vibration Resistance 0 to 6G (55Hz maximum) Shock Resistance RY2, RY22: 100N (approximately 10G) RY4, RY42, RM2: 200N (approximately 20G) Electrical Life Expectancy RY2, RY4: over 200,000 operations (120V, 3A) RY22, RY42: over 200,000 operations (120V AC, 1A) RM2: over 500,00 operations (240V AC, 5A) Ordering Information Order standard voltages for fastest delivery. Allow extra delivery time for non-standard voltages. Basic Part No. Coil Voltage: RY4S-U AC110-120V Mechanical over 50,000,000 operations E-22 Operating Temperature –30 to +70°C Weight DPDT: 23g; 4PDT: 34g (approximately) www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Relays RY/RM Series Part Numbers Part Numbers: RY/RM Series with Options Termination Contact Configuration Basic Part No. S Solder/plug-in V PCB 0.031" (0.8mm) wide Indicator Light Check Button Indicator Light and Check Button Top Bracket DPDT small footprint RY2S-U RY2S-UL RY2S-UC RY2S-ULC RY2S-UT DPDT (bifurcated contacts) RY22S-U RY22S-UL — — RY22S-UT DPDT wide footprint RM2S-U RM2S-UL RM2S-UC RM2S-ULC RM2S-UT 4PDT RY4S-U RY4S-UL RY4S-UC RY4S-ULC RY4S-UT 4PDT (bifurcated contacts) RY42S-U RY42S-UL RY42S-UC RY42S-ULC RY42S-UT DPDT small footprint RY2V-U RY2V-UL RY2V-UC RY2V-ULC — DPDT (bifurcated contacts) RY22V-U RY22V-UL — — — DPDT wide footprint RM2V-U RM2V-UL RM2V-UC RM2V-ULC — 4PDT RY4V-U RY4V-UL RY4V-UC RY4V-ULC — 4PDT (bifurcated contacts) RY42V-U RY42V-UL RY42V-UC RY42V-ULC — E Coil Ratings Rated Current ±15% at 20°C 60Hz 50Hz RM2, RM2, RY2, RY2, RY4, RY4, RY22 RY22 RY42 RY42 Rated Voltage (V) 6V 12V 24V 120V* 240V † AC 150mA 75mA 37mA 7.5mA 3.2mA 6V 12V 24V 48V 110V‡ DC 200mA 100mA 50mA 11mA 5.5mA 170mA 86mA 42mA 8.6mA 3.7mA 240mA 121mA 60.5mA 13.1mA 6.6mA RY2, RY22 RM2, RY4, RY42 128mA 64mA 32mA 18mA 150mA 75mA 36.9mA 18.5mA 9.1mA — Coil Resistance ±10% at 20°C RM2, RY2, RY4, RY22 RY42 18.8Ω 76.8Ω 300Ω 7,680Ω 31,200Ω 9.4Ω 39.3Ω 153Ω 4,170Ω 15,210Ω RY2, RY22 RM2, RY4, RY42 47Ω 188Ω 750Ω 2,660Ω — 40Ω 160Ω 650Ω 2,600Ω 12,100Ω Coil Inrush (60Hz) RM2, RY2, RY4, RY22 RY42 250mA 120mA 56mA 12mA 7mA 340mA 170mA 85mA 16mA 8mA Coil Inductance Energizing De-Energizing RM2, RM2, RY2, RY2, RY4, RY4, RY22 RY22 RY42 RY42 0.09H 0.37H 1.5H 37H 130H 0.08H 0.30H 1.2H 33H 130H 0.06H 0.22H .9H 22H 77H 0.04H 0.16H 0.63H 15H 62H N/A * For RY4/RY42/RM2 relays = AC110/120V AC. † For RY4/RY42/RM2 relays = 220/240V AC. ‡ For RY4/RY42/RM2 relays = 100/110V DC. Contact Ratings (bifurcated) RY42, RY22 Contact Ratings (gold plated) RY4, RY2 Voltage 30V DC 100V DC 120V AC 240V AC Contact DPDT 4PDT DPDT 4PDT DPDT 4PDT DPDT 4PDT www.idec.com Resistive UL CSA 3A 5A 0.2A 0.2A 3A 5A 3A 5A 3A 5A — — 3A 5A 3A 5A Inductive UL CSA 3A 5A 0.2A 0.2A 1.5A 5A 0.8A 5A 1.5A 1.5A 0.2A 0.2A 1.5A 5A 0.8A 5A Voltage Resistive UL/CSA 30V DC 1A Inductive UL/CSA 0.5A 120V AC 1A 0.5A 240V AC 0.8A 0.4A Contact Ratings RM2 Resistive Inductive Voltage Nominal UL CSA Nominal UL CSA 30V DC 110V DC 120V AC 240V AC 5A 0.4A 5A 5A 5A 0.4A 5A 5A 5A — 5A 5A USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC 2.5A 0.4A 2.5A 2A — — 2.5A 2A 2.5A 0.4A 2.5A 2A E-23 Relays Ratings Relays RY/RM Series Applicable Sockets Part Numbers: Sockets Standard DIN Finger-Safe Relay Panel Mount PC Mount Rail Mount DIN Rail Mount RY2S RY22S SY2S-05 SY2S-05C SY2S-51 RM2 SM2S-05 SM2S-05C SM2S-51 RY4S RY42S SY4S-05 SY4S-05C SY4S-51 Springs (optional) Part Number SY2S-61 SY4S-61 SY4S-62 See Section F for details on sockets. All DIN rail mount sockets shown above can be mounted using DIN rail BNDN1000. Use With SY2S-02F1➂ SFA-101① SFA-202➁ SY2S-05, -05C SFA-301① SFA-302➁ SY4S-51F1➂ SY2S-51, -61 SY4S-02F1➂ SFA-101① SFA-202➁ SY2S-05, -05C SFA-301① SFA-302➁ SY4S-51F1➂ SY4S-51, -61 ① Top latch ➁ Side latch ➂ Pullover spring Relays E Internal Circuits 1 5 9 13 (-) 4 8 12 14 1 5 9 13 (+) (-) 2 6 10 3 7 11 4 8 12 14 (+) RY2, RY22 RY4, RY42 4 1 5 8 9 12 (+)14 13(-) RM Image as viewed from bottom of relay. Refer to socket for exact wiring layout (Section F). E-24 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Relays RY/RM Series Maximum Switching Capacity RY4/RM2 RY2 5 5 3 AC inductive 1 Load Current (A) Load Current (A) AC resistive DC resistive DC inductive 0.5 0.1 1 5 50 10 100 AC resistive AC inductive 1 0.1 1 200 300 Load Voltage (V) DC resistive DC inductive 0.5 5 10 50 100 200 300 Load Voltage (V) RY Bifurcated 1 AC resistive Load Current (A) 0.5 AC inductive DC resistive E DC inductive Relays 0.1 0.05 0.01 1 10 5 50 100 200 300 Load Voltage (V) Electrical Life Curves RY2 Bifurcated Contacts RY42, RY22 DC 30V Resistive AC 220V Resistive 100 50 20 1 2 Load Current (A) 500 100 50 DC 100V Resistive DC 100V Inductive 10 0 3 5 2 Load Current (A) 3 RY4 AC 220V Resistive 100 50 AC 110V Inductive AC 220V Inductive DC 30V Resistive DC 30V Inductive 100 50 20 20 10 10 1 Load Current (A) DC 100V Resistive DC 100V Inductive 1 Load Current (A) DC 30V Resistive 250V AC Inductive 1A 2A 240V AC Resistive 3A Load Current (A) www.idec.com 4A 5A 10 6 30V DC Resistive 30V DC Inductive 10 5 110V DC Resistive 110V DC Inductive DC 30V Inductive 1000 1000 500 100 50 AC 110V Inductive Life (x 10,000) Operations 5 10 7 Life (x 10,000) Operations 120V AC Resistive 120V AC Inductive 10 4 AC 100V Resistive AC 220V Resistive Life (number of operating cycles) Life (number of operating cycles) AC 110V Resistive RY4 DC Load 7 10 6 10 500 RM2 RY4 AC Load 10 500 20 AC 110V Inductive AC 220V Inductive 10 0 1000 Life (x 10,000) Operations AC 110V Resistive 500 1000 DC 30V Inductive Life (x 10,000) Operations 1000 Life (x 10,000) Operations Life (x 10,000) Operations 1000 500 100 50 DC 100V Resistive DC 100V Inductive AC 220V Inductive 10 4 1A 2A 3A 4A Load Current (A) 5A 10 0 1 2 3 4 Load Current (A) 5 10 0 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC 1 2 3 4 Load Current (A) 5 E-25 Relays RY/RM Series Dimensions With Top Bracket Plug-in RY2S-UT, RY22S-UT Solder Terminal Plug-in RY2S RY22S Dimensions in the ( ) include a hold-down spring. 3 × ø1.2 oblong hole 6.3 14 8 9 12 13 14 2 14.5 14 RY4S RY42S 35.6 max. 5.4 2.6 4.4 RY4S-UT RY42S-UT 2.6 0.5 2.2 × ø1.2 oblong hole 4.1 4.4 Dimensions in the ( ) include a hold-down spring. 6 7 8 9 10 11 12 13 6.3 5 6.4 4 7 8 10 11 12 14 2 21.5 21 PCB Terminal RY2V RY22V 35.6 max. 6.4 0.8 4.1 8-ø1 holes 4.1 PCB Terminal RY4V, RY42V 35.6 max. 4 12 13 14 21 27.5 8 9 12.7 4.4 4 5 13.2 6.4 14 1 0.5 13 14 4 2.6 12 8-ø1 hole 12.7 9 6.4 8 7.15 4 5 27.5 0.5 0.5 1 7.15 0.8 2.6 PCB Terminal RM2S, RM2V 0.5 35.6 max. 3 6 9 13 14 3.5 35.6 max. 2 5 6.4 4 38 3 43.2 2 27.5 0.5 1 1 27.5 2.2 × ø1.2 oblong hole 4.4 Total length from the panel surface including relay socket SY4S-05A: 61.5 (63.5) max., SY4S-51: 39.6 (41.6) max. 0.8 0.5 6.6 4 7 8 10 11 12 13 14 12.7 3 6 9 6.4 2 5 27.5 1 7.15 4.1 2.6 14-ø1 holes 0.5 Relays E 5.4 5 6.4 12 38 9 13 43.2 8 27.5 5 0.5 4 3.5 35.6 max. 4 1 1 27.5 2.6 0.5 4.1 3 × ø1.2 oblong hole 2.6 4.4 Total length from panel surface including relay socket SY2S-05A: 61.5 (63.5) max., SY2S-51: 39.6 (41.6) max. All dimensions in mm. 35.6 max. E-26 4 21 4.4 www.idec.com 4.4 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC