Preview only show first 10 pages with watermark. For full document please download

Idlv-3440dm Professional 4-channel Dvb Receiver And Transmodulator

   EMBED


Share

Transcript

IDLV-3440DM Professional 4-Channel DVB Receiver and Transmodulator En IDLV-3440DM Professional 4-Channel DVB Receiver and Transmodulator User Manual En Table of Contents Notices     2 Before using the device 3 Overview     4 Front panel and Rear panel instructions    5 Operation instructions via Front Panel        6 Web Control 13 Installation 25 Accessories    25 Technical Specifications 26 Safety 27 Warrenty, service and support     30 1 Notices COPYRIGHT (Copyright © 2015 Inverto Digital Labs ) Not to be copied, used or translated in part or whole without Inverto prior consent in writing except approval of ownership of copyright and copyright law. WARRANTY This warranty does not cover parts which may become defective due to misuse of the information contained in this manual. Read this manual carefully and make sure you understand the instructions provided. For your safety, be aware of the following precautions. WARNING! IMPORTANT SAFETY INSTRUCTIONS   CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. WARNING • To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. • To avoid explosion danger, do not dispose of batteries in an open fire. CE MARK FOR EUROPEAN HARMONISED STANDARDS The CE mark which is attached to these products means it conforms to EMC Directive (89/336/EEC) and Low Voltage Directive (73/23/EEC). IMPORTANT INFORMATION Please retain the original packaging, should it be necessary at some stage to return the unit. Disposal of Old Electrical and Electronic Equipment (Applicable in the European Union and other European countries with separate collection systems) This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. The recycling of materials will help to conserve natural resources. For more detailed information about recycling of this product, please contact your local Civic Office, your household waste disposal service, or the shop where you purchased the product. COPYRIGHTS Television programmes, movies, video tapes, discs, and other materials may be copyrighted. Unauthorized recording of copyrighted material may be against the copyright laws in your region. Also, use of this product with cable television transmissions may require authorization from the cable television operator or transmitter/owner. VENTILATION • • • • • • Do not expose the product to high temperatures, such as placing it on top of other product that produce heat or in places exposed to direct sunlight or spot lights. The ventilation slots on top of the product must be left uncovered to allow proper airflow into the unit. Do not stand the product on soft furnishings or carpets. Do not stack electronic equipments on top of the product. Do not place the product in a location subject to extreme changes in temperature. The temperature gradient should be less than 10 degrees C/hour. Place the product in a location with adequate ventilation to prevent the build-up of heat inside the product. The minimum ventilation space around the unit should be 7 cm. The ventilation should not be impeded by covering the ventilation openings with items, such as newspapers, table cloth, curtains, etc. POWER SOURCES • The product is not disconnected from the AC power source (mains) as long as it is connected to the power outlet or wall socket, even if the product is turned off. • If the product will not be used for a long period of time, disconnect it from the AC power outlet or wall socket. 2 En Before Using the device Thank you for purchasing the IDLV-3440DM Professional HDTV Integrated Receiver Decoder. This User Manual is written for operators/users of the IDLV-3440DM to assist in installation and operation. Please read this user manual carefully before installation and use of the devic. FOR YOUR SAFETY This equipment is provided with a protective earthing ground incorporated in the power cord. The main plug shall only be inserted in a socket outlet provided with a protective earth contact. Any interruption of the protective conductor, inside or outside the device, is likely to make the device dangerous. Do not remove the covers of this equipment. Hazardous voltages are present within this equipment and may be exposed if the covers are removed. Only Inverto trained and approved service engineers are permitted to service this equipment. The supplied AC power cable must be used to power the device. If the power cord becomes damaged it must be replaced. No operator serviceable parts inside. Refer servicing to Inverto trained and approved service engineers. For the correct and safe use of the device, it is essential that both operating and servicing personnel follow generally accepted safety procedures in addition to the safety precautions specified in this manual. Whenever it is likely that safety protection is impaired, the device must be made in-operative and secured against unintended operation. The appropriate servicing authority must be informed. For example, safety is likely to be impaired if the device fails to perform the intended measurements or shows visible damage. WARNINGS • The mounting environment should be relatively dust free, free of excessive vibration and the ambient temperature between 0C° to 40C°. Relative humidity of 20% to 80% (non-condensed) is recommended. • Avoid direct contact with water. • Never place the equipment in direct sunlight. • The outside of the equipment may be cleaned using a lightly dampened cloth. Do not use any cleaning liquids containing alcohol, methylated spirit or ammonia etc. • For continued protection against fire hazard, replace line fused only with same type. • Air intake for cooling is achieved via holes at the side of the device and the fans inside. The air flow should not be obstructed. Therefore, the device has to be placed on a flat surface, leaving some space at the sides of the device. • When in operation, the internal temperature should not exceed the limit of 70C°. 3 Overview IDLV-3440DM integrates 4 DVB Receiver and Transmodulator in one 1U 19” chassis. It provides operators an ideal DTV headend setup solution by combining multi-channel receiving, descrambling, remultiplexing and DVB QAM/ COFDM modulation and TS over IP operations together in one single unit. Equipped with 4 independent tuner front ends with various factory options for DVB-T/T2, DVB-S2/S, DVB-C, DTMB, ISDB-T and ATSC types, standard ASI and TS/IP I/O interfaces, IDLV-3440DM ensures compatibility with all types of transmission media. The standard four PCMCIA common interface slots on the rear panel support the most popular CI CAMs in the market to de-crypt multiple pay TV services. Being a highly integrated, compact size device offering wide flexibility in system configuration and reliable functionality, makes the IDLV-3440DM one of the most competitive product in the head-end market. CHARACTERISTICS • • • • • • • • • • • 4x Tuner Input, Supports variety of input options DVB-T2/T/S2/S/C/DTMB/ATSC/ISDB-T) Supports DVB-S2 Input Stream Identifier (ISI, optional) and DVB-T2 Multi PLP and SFN MIP pass through 4 x DVB QAM/COFDM Modulation, 4 x RF Channel Output (Adjacent channel) Built-in TS re-multiplexer receives from ASI, CI Slot1 to CI Slot4 and TS/IP inputs 4×DVB-CI Slots, multi-program decryption, BISS-1 and BISS-E decryption ASI output the transport stream from CI Slot1 to CI Slot4 or BISS decryption 1xchannel full duplex TS over IP or 5xchannels IP out without IP input Remote Control and Monitoring by SNMP v2, HTTP WEB and Proprietary PC software On Site software update through IP or USB RSSI, received signal strength, Eb/N0, C/N and BER monitoring Redundant power supply BLOCK DIAGRAM The diagram below shows a top level architecture and functional block diagram of the IDLV-3440DM Platform: 4 En Front panel and Rear panel Instructions FRONT PANEL LED POWER LED WARNING LED ALARM VFD DISPLAY CONTROL LED TUNER LOCK OPERATION BUTTONS MODULATOR STATUS LED POWER TS/IP RF MONITOR -20dB When turned on, the Green LED indicates that power is available. When turned off, the power is not available or failed LED WARNING Led On Led Off LED Alarm LED ON: Alarm or alarms have been triggered, For alarm description, please refer to details in the table 10. LED OFF: The equipment works properly LED TUNER LOCK LED ON: Tuner input is locked LED OFF: Tuner is un- locked VFD Display Display menus, submenus and their parameters Cursor Keys UP, DOWN, LEFT, RIGHT. Used to navigate through the menu system ENTER key Confirm a selection then return to previous menu EXIT Key Exit and return to previous menu Control RJ-45 Ethernet port for equipment control and monitoring Control - USB USB port for firmware upgrade TS/IP RJ-45 TS over IP Ethernet port RF Monitor To monitor the modulated signal 5 REAR PANEL 2 4 1 1 2 3 4 5 6 7 8 9 10 11 6 5 3 RS-232 Alarm Tuner In-1/4 Common Interface ASI Out-1/4 ASI In ASI Out-5 ASI Out-6 RF Out RF In backup Power Supply 7 9 8 11 10 Reserved for factory use Alarm relay interface 4 Tuner Inputs 4 Common Interfaces 4 pass through ASI output ASI input Main ASI output Backup ASI output port Main RF output port RF backup signal input when the built-in modulator is down Input Dual AC power supply Operation instructions via Front Panel With the keypad and display panel on the front panel, Users can configure the device locally. OVERVIEW OF MENU Power on the device and wait for initialization complete, the Local IP address will be displayed on the VFD panel. Press{ENTER}to get into the main menu. Main menu Status I/O Status 6 TS/IP Status (Full Duplex/ Multiple Output) Configuration Slave board Remux TS/IP (Mode: Multiple Output/ Full Duplex) COFDM /QAM System RF Setting ASI Output En DESCRIPTION OF MENU The main menu items can be selected with the keypad. By pressing the [Enter], the user navigates to the submenus, which are selected in the same manner. Status: Submenu Layer 1 Submenu Layer 2 Parameters Tuner Status I/O Status Tuner 1/2/3/4 Lock/Unlock Tuner 1/2/3/4 Valid bit rate and total bit rate ASI Valid bit rate and total bit rate IP Valid bit rate and total bit rate Remux Bit rate Valid bit rate and total bit rate Modulator Moulator 1/2/3/4 Valid bit rate and total bit rate Link Status Display IP link status:10M/100M/1000M/Disconnect Input Bit rate Output Bit rate Gigabit Output Status TS/IP Status )Full Duplex( Gigabit Input Status TS/IP Status )Multiple Output( Description UDP Packets/s Display IP out UDP packet rate Column FEC Pkts/s Display IP out column FEC packet rate Row FEC Pkts/s Display IP out row FEC packet rate IP Input Status Display IP in lock/unlock status IP Input Protocol Display the protocol of IP input Column/Row FEC Display the mode of column FEC and row FEC Pkts per UDP Frame Display the packets per UDP frame Received TS Frames Display the received TS frames Fixed RTP Frames Display the fixed RTP frames FEC Counter Display the FEC packets that has been received FEC Counter Reset Reset the FEC packets counter Display IP link Status: 10M/100M/1000M/Disconnect Link Status Configuration – Slave Board Setup: Slave Board Setup Tuner 1/2/3/4 CI 1/2/3/4 BISS 1/2/3/4 7 Slave Board Setup – Tuner 1/2/3/4: Submenu Parameters & Description LNB LO Frequency To configure the local oscillator frequency according to the right satellite, its range is from 1000 to 26,500MHz. Satellite Frequency To configure the satellite down link frequency according to the right satellite, its range is from 1000 to 26,500MHz. Symbol Rate To configure the symbol rate of QPSK signal, its range is from 1000 to 45,000KBaud. LNB Voltage To select the correct LNB voltage output from the F-connector, user can choose between Off, 13V and 18V. LNB 22KHz To activate the LNB 22KHz control signal to the LNB, user can select between On and Off. DiSEqC Default Value To configure the DiSEqC control, user can select Port A, Port B, Port C, Port D or DiSEqC OFF. Slave Board Setup – CI 1/2/3/4: Submenu CAM Name Setup Parameters & Description Default Value CAM Name To check what kind of CAMs have been inserted. To set which programs should be descrambled by CI Slave Board Setup – BISS 1/2/3/4: Submenu Parameters & Description BISS Mode To select the BISS mode, user can choose between Off, BISS-1 and BISS-E. BISS Key Enter 12 numbers key BISS ID Enter 14 numbers ID Program To select which services will be decrypted by BISS. Default Value OFF Config – Remux: Submenu Parameters & Description Program List Program List: Select the programs to remux. Click on Enter to select, double click to cancel. (The program(s) will be marked with an asterisk (*) once be selected) Tuner 1: select the program from tuner 1 Tuner 2: select the program from tuner 2 Tuner 3: select the program from tuner 3 Tuner 4: select the program from tuner 4 ASI Input: Select the program(s) inputted via ASI input port. IP Input: Select the program(s) inputted via IP input port. (Note: this submenu is displayed only when the IP I/O is configured as full-duplex mode.) Bit Rate Output Bit Rate: Key in the bit rate of the new generated MPTS, valid range from 100~216000 Kb/s Output Bit Rate: 38015Kb/s 188 Byte / 204 Byte 188 Byte TS ID: Key in the TSID of the new generated transport stream, valid range from 0 to 65535 decimal TS ID:00008 Packet Size TS ID 8 Default Value En Remove CA Insert EIT Output Program ON: Remove the CA descriptors that are carried within the inputted TS over ASI or IP OFF: Keep the CA descriptors. OFF ON: Insert EIT into the output stream, EIT data may come from ASI or IP input port OFF: Do not insert EIT into the output stream. OFF Display the selected program names Config – TS/IP (Multiple Output Mode): Submenu Channel 1~4 (the streaming comes from Tuner 1~4 correspondingly.) Channel 5 (the streaming comes from ASI input.) Parameters & Description Default Value Mux/ASI Out: Set the source for the IP output (This menu is only valid for IP Channel 5) Mux/ASI Out: Mux Uni/Multi IP Address: Set the destination IP address for the IP output Uni/Multi IP Address: 238.069.070.001 Uni/Multi UDP Port: Set the destination port number, valid range from 1~65535 Uni/Multi UDP Port: 01234 Target MAC Address: Set the destination port number MAC Address Target MAC Address: 00:00:24:56:12:67 Gigabit Out Switch: ON/OFF: To switch on/off the current channel Gigabit Out Switch: ON Gigabit Address: set the IP address of the IP port IP Board IP Adress:10.10.10.10 Gigabit Subnet Mask: Set the net mask of the IP port IP Board Net Adress: 255.255.255.0 Gigabit Gateway: Set the gateway of the IP port IP Board Gateway:10.10.10.1 Gigabit MAC Address: Display the MAC address of the IP port Gigabit Local Protocol: UDP: Set UDP protocol to IP output RTP: Set RTP protocol to IP output Protocol: UDP TS Pkts Per UDP: Set the number of TS packets that can be carried by each UDP packet, valid range from 1~7 TS Pkts Per UDP: 7 Time To Live: Set TTL to the output IP packets, valid range from 1~255 Time To Live: 255 Type Of Service: Min Delay/Max Reliability/Max Throughput/Min Monetary Cost/Normal Type Of Service: Min Delay Gateway MAC Address: Set the MAC address of the gateway under which the device is connected Gateway MAC Address: ff:ff:ff:ff:ff:ff 9 Config – TS/IP (Full Duplex Mode): Submenu Gigabit Output Gigabit Local Gigabit Input 10 Parameters & Description Default Value Gigabit Out Switch: Enable/Disable Gigabit Out Switch: ON Source: Set the source for the IP output Remux Protocol: UDP: Set UDP protocol to IP output RTP: Set RTP protocol to IP output Protocol: UDP TS Pkts Per UDP: Set the number of TS packets that can be carried by each UDP packet, valid range from 1~7 TS Pkts Per UDP: 7 Time To Live: Set TTL to the output IP packets, valid range from 1~255 Time To Live: 1~255 Type Of Service: Min Delay/Max Reliability/Max Throughput/Min Monetary Cost/Normal Type Of Service: Min Delay Uni/Multi IP Address: set the destination IP address Uni/Multi Address: 238.069.070.001 Uni/Multi UDP Port: Set the destination port number, valid range from 1~65535 Uni/Multi UDP Port: 01234 ProMPEG FEC Switch: Enable/Disable ProMPEG FEC Switch: Disable ProMPEG FEC Mode: 1D,5x5/1D,5x20/1D,10x10/2D,5x5/2D,5x20/2D,10x10 ProMPEG FEC Mode : 1D,5x5 FEC Alignment: Annex A/Annex B FEC Alignment: Annex A Gigabit Address: Set the IP address of the IP port Gigabit Adress: 010.010.010.010 Gigabit Subnet Mask: Set the net mask of the IP port Gigabit Subnet Mask: 255.255.255.000 Gigabit MAC Address: Display the MAC address of the IP port Gigabit Gateway: Set the gateway of the IP port Gigabit IP Gateway: 010.010.010.001 Gateway MAC Address: Set the MAC address of the gateway under which the device is connected Gateway MAC Address: ff:ff:ff:ff:ff:ff:ff Uni/Multi Address: Set the uni/multicast target address of the IP input Uni/Multi Address: 238.069.070.002 Uni/Multi UDP Port: set the target port number of the uni/multicast IP input, valid range from 1~65535 Uni/Multi UDP Port: 01234 TS Clock Recovery: Auto: It is suggested to set Auto when there is accurate PCR carried by the inputted TS/IP Fixed Rate: When fixed rate is selected, user has to configure a bit rate to regenerate the TS clock. The configured fixed bit rate has to be a little bit higher than the bit rate of the inputted TS/IP TS Clock Recovery: Auto En Config – Modulation (QAM): Submenu Modulator Output Parameters & Description Default Value ON/OFF: put OFF to switch off the QAM carrier ON Encoder1/Encoder2/Encoder3/Encoder4: The stream output from the corresponding encoder will be delivered to modulator directly. Remux: The stream from built-in remux will be delivered to modulator IP In: The stream from IP input will be delivered to modulator ASI Input: the stream from ASI input will be delivered to modulator REMUX Constellation 16QAM/32QAM/64QAM/128QAM/256QAM 64QAM Symbol Rate valid range from 782~12500 6875 Yes: The spectrum is inverted No: The spectrum is normal NO Output Source Spectral Invert Config – Modulation (COFDM): Submenu Modulator Output Output Source Constellation Bandwidth Guard Interval Code Rate Spectral Invert TMS Parameters & Description Default Value ON/OFF: Put OFF to switch off the QAM carrier ON Encoder1/Encoder2/Encoder3/Encoder4: The stream output from the corresponding encoder will be delivered to modulator directly. Remux: The stream from built-in remux will be delivered to modulator IP In: The stream from IP input will be delivered to modulator ASI Input: The stream from ASI input will be delivered to modulator REMUX APSK/16QAM/64QAM 64QAM 5M/6M/7M/8M 8M 1/32, 1/16, 1/8, 1/4 1/32 1/2, 2/3, 3/4, 5/6, 7/8 7/8 Yes: The spectrum is inverted No: The spectrum is normal NO 2K IFFT DM/8K IFFT DM/4K IFFT DM 8K IFFT DM 11 Config – RF Setting: Submenu RF Frequency Parameters & Description Default Value valid range from 30,000~1,000,000KHz 474000 valid range from 90~120dBuV 100 RF Level adjust (-1dBuV~4dBuV) 0 dBuV Backup Switch Auto: Automatically output the RF signal inputted via Backup RF input port when the built-in modulator is down Main: Always output from the built-in modulator Spare: Always output from the backup RF input Auto RF Out Restore (the submenu displays only when Auto mode is selected.) Spare to Main: Switch to Main source (the built-in modulator) Main to Spare: Switch to Backup RF source RF Level Config – ASI Output: Submenu ASI Output Parameters & Description ASI Output Source: Select the source for ASI output Tuner1 / Tuner2 / Tuner3 / Tuner1 / Remux / IP In / ASI Input Default Value Remux SYSTEM Submenu Network Setting Parameters & Description Default Value IP Address: Set the IP address of the device, valid range from 0.0.0.0~255.255.255.255 IP Address: 10.10.70.48 Subnet Mask: Set the net mask of the device, valid range from 0.0.0.0~ 255.255.255.255 Net Mask: 255.255.255.0 Gateway: Set the gateway of the device, valid range from 0.0.0.0~255.255.255.255 Gateway: 10.10.70.1 MAC Address: To display the MAC address Remote Setting Device Label Software Version Factory Default 12 Trap IP Address: Set the IP address of the SNMP Trap server, valid range from 0.0.0.0~255.255.255.255 Trap IP Address: 10.10.70.25 Edit Product name: User allows to rename the device, press Enter and key in the name of the device, then press Enter to confirm the setting or press Exit to cancel. Software Version: Display the software version Factory Default: Enter = Yes: press Enter to recall the factory default settings. Exit = No: press Exit to cancel Note: the IP address of the device is not reset to the factory setting! En MAC Address: To Modify the MAC address Machine Type (Reserved for factory setup) S/N: Display the serial number of the device Gigabit MAC Address: To Modify the Gigabit MAC address Detail Version: Display the detail version of MCU,FPGA,LINUX OS Edit Login ID: Press Enter and key in the login ID for WEB management Default Login ID: root WEB Login Password Edit Login Password: Press Enter and key in the password for WEB management Default Login Password: 12345 Gigabit Mode Gigabit Mode: Multiple Output: The IP I/O is configured as multiple uni/multicast output mode, which delivers up to 5 streams over IP. There are 4 stuffed or un-stuffed SPTS (lower bit rate but less PCR accurate than normal SPTS, from local encoders) and 1 MPTS from built-in remultiplexer over the IP with different Unicast or Multicast IP addresses. Full Duplex: The IP I/O is configured as full duplex mode, which allows only one MPTS or SPTS over IP input and output in uni/multicast at the same time. Note: The device will reboot after modification. Gigabit Mode: Multiple Output WEB Login ID Web Control IDLV-3440DM has an integrated web server. This web server allows the configuration and status requests with a standard web browser. To operate a IDLV-3440DM, first make sure the Ethernet control port is well connected in the network and could be pinged by the host PC, and then enter the IP address of the IDLV-3440DM into the browser, there will be a pop-up showed asking for login user and password.After login the device can be operated. The default user name is “root” with password “12345”. The username and password can be modified via front panel webpage. A new user and password can be set via front panel in case of the user name and password are forgotten. STATUS Via the status page, user can have an overview of the working status of the IDLV-3440DM. Status of Input: 13 Status of Output: Status of Tuner: Status of Modulator: 14 En Status of TS/IP Linkage: Status of Power Supply: CONFIGURATION All parameters for Tuners, CI, BISS, QAM Output, RF Setting and ASI Output can be found under the page “Configuration”. Click the button “Apply” to submit your configuration or click the button “Cancel” to cancel and restore the previous settings. Receiver: Set parameters for the receiver. Click “Apply” button to submit, or click “Cancel” button to cancel 15 Tuner: There are 6 options to set DVB-S2 parameters. After signal locked, the TUNER LOCK indicator on front panel will turn green. LNB Frequency: Input LNB frequency Satellite Frequency: Input downstream frequency of satellite Symbol Rate: Input symbol rate of satellite LNB Voltage: Select the correct LNB voltage output of the F-connector: Off, 13 V, 18 V. LNB 22KHz: Activate the LNB 22 kHz control signal to the LNB: On or Off. DISQEC: Can select OFF/Port A/Port B/Port C/Port D Note: Please contact the local satellite operator for the satellite frequency and symbol rate. Normally, 13V switches the LNB to receive Vertical/Left hand polarization while 18V receive Horizontal/Right hand. Normally, 22KHz control signal switches the LNB to receive high band if any CI: This page will show the CAM name and program list. The user can select the services which can set the program as Bypass or Descramble. Apply is for submit the settings. BISS: The user can set the correct BISS mode and enter the BISS ID and Key. Then, to set the program which need to be descrambled. Apply for submit the settings. 16 En Modulation: In the page user can enable or disable and setup the source for each of the 4 independent built-in modulators and setup the parameters except the frequency. RF Setting: Set up the RF parameters in the page “RF setting”. The output RF frequency ranges from 30,000 to 1,000,000 KHz, and output RF level ranges from 90~110dBuV. ASI Output: Under ASI Output page, select the source for ASI output, there are 10 sources can be selected in the list which are: Tuner1 / Tuner2 / Tuner3 / Tuner4 / ASI Input / Remux TS1 / Remux TS2 / Remux TS3 / Remux TS4 / IP In / ASI Input. The default ASI output source is ASI input. 17 REMUX In the “Remux” page, select the program(s) that to be remultiplexed and configure the necessary parameters for the new generated transport stream. Packet Size: 188 Byte / 204 Byte Bit Rate (Kbps): Set the bitrate for the new generated MPTS, valid range from 100~216000 Kb/s. The bitrate should be at least bigger than the total bitrate of selected programs, otherwise, packets may dropout. TS ID: Set the TSID of the new generated transport stream, valid range from 0 to 65535 decimal. Insert EIT: ON: Insert EIT into the output stream, EIT data may come from ASI or IP input port OFF: EIT will not be inserted into the output stream. Remove CA: ON: Remove the CA descriptors that are carried within the inputted TS over ASI or IP OFF: Keep the CA descriptors 18 En TS/IP IDLV-3440DM support two TS/IP operation mode, which are respectively Multiple Output Mode and Full Duplex Mode. To switch between the two mode please refer to chapter 7.6. Multiple Output Mode: Gigabit Out: There are up to 4 streams encapsulated onto TS/IP output when TS/IP is configured as multiple output mode. In this mode, all 4 TS streams from internal remultiplexier could be sent through the TS/IP port while the 5th IP slot could be fed with ASI input. Gigabit In: IP in is not supported under multiple output mode. Gigabit Local: Gigabit Address: Set the IP address of the IP port Gigabit Subnet Mask: Set the net mask of the IP port Gigabit MAC Address: Display the MAC address of the IP port, cannot be modified by user Gigabit Gateway: Set the gateway address under which the IP port is connected Gateway MAC Address: Set the MAC address of the gateway under which the device is connected, this is necessary when the IP streaming is needed to pass through the gateways 19 Protocol: Select UDP or RTP protocol for the IP output TS Pkts Per UDP: Set the number of TS packets that can be carried by each UDP packet Time To Live: Set TTL to the output IP packets Type of Service: Select the service type for the outputted IP streaming. Full Duplex Mode: In this mode, the IDLV-3440DM supports single uni/multicast input and output in parallel. Set the IP I/O parameters in following pages. Gigabit Out: IP Out Switch: Enable or Disable the IP output Source: Select the source for the IP output in the dropdown list Protocol: Select UDP or RTP protocol for the IP output TS Pkts Per UDP: Select the number of TS packets that can be carried by each UDP packet Time To Live: Set TTL to the output IP packets Type of Service: Select the service type for the outputted IP streaming Uni/Multi IP Address: Set the unicast or multicast address for the output IP streaming Uni/Multi UDP Port: Set the destination port number, valid range from 1~65535 ProMPEG FEC Switch: Enable or Disable the ProMPEG FEC (Note: The two submenus below are available only when the ProMPEG FEC is switched on and has be applied) ProMPEG FEC Mode: Select the mode of ProMPEG FEC from the dropdown list Column FEC UDP Port: Set the port number for column FEC Row FEC UDP Port: Set the port number for row FEC FEC Alignment: Set the alignment for FEC Test Drop Packets: Set the test drop packets 20 En Gigabit Input: Note the Column and Row FEC UDP ports have to be configured if Pro-MPEG protocol is used in the IP signal inputted. Uni/Multicast IP Address: Set the multicast address for the incoming IP streaming. To receive a unicast streaming, the submenu can be ignored. Uni/Multicast UDP Port: Set the port number for the incoming IP streaming. TS Clock Recover: Auto: It is suggested to set Auto when there is accurate PCR carried by the inputted TS/IP Fixed Rate: When fixed rate is selected, user has to configure a bit rate to regenerate the TS clock. The configured fixed bit rate has to be a higher than the bit rate of the inputted TS/IP. Gigabit Local: Gigabit Address: Set the IP address of the IP port Gigabit Subnet Mask: Set the net mask of the IP port Gigabit MAC Address: Display the MAC address of the IP port, cannot be modified by user Gigabit Gateway: Set the gateway address under which the IP port is connected Gateway MAC Address: Set the MAC address of the gateway under which the device is connected, this is necessary when the IP streaming is needed to pass through the gateways 21 SYSTEM The system page shows all information of the device, including device name, serial number, software version, and so on. User can implement the local network settings, TS/IP operation mode, modulation mode, software upgrade, remote reboot and so on. Device: Device name: Check the name and the serial number of this device. User can resign this product name at will, the device name should be less than 24 characters. The serial number is read-only. Serial Number: Show the serial number for the device, cannot be modified by user. Gigabit Mode: Switch the TS/IP operation mode between “Multiple Output” and “Full duplex”. The device will reboot after change. Network Setting: IP Address: Set the device’s IP address Network Mask: set the net mask of the device Gateway: Set the gateway address of the device MAC: Display the MAC address of the device, cannot be modified by user 22 En Version: User can check versions of the device, as shown in the picture below. Web Login: Username: Set the username for webpage login Password: Set the password for webpage login Factory Default: Click the button “Default” to restore the factory default settings to the device. Note: The IP address of the device and the operation mode of the Gigabit board will not be restored. 23 System Reboot: User can reboot this device by clicking the button “Reboot”. Upgrade: IDLV-3440DM support online firmware upgrade. To upgrade the device, load the upgrade file first by clicking on “Browse…”, in the opened window select the correct upgrade file, then click on “Upgrade”, wait the device complete the upgrade procedure. It is recommended to restore the factory default settings after firmware upgrade. 24 En Presets: The user can save 16 groups settings on the unit and recall one of them to use. User can download these settings to the PC and use for other units also. Installation It is highly recommended to fix the IDLV-3440DM be mounted in EIA standard 19” rack, any other mounting method may lead to damage to the device. • Open the box and take out the device with care. Inspect if there is any damage to the appearance of the device. • Fix the device into the standard EIA 19” rack. • Connect the input and output cables. • Plug the power cable into the AC Power input socket. The POWER Indicator LED (A4) should be green and always light on during working. The IDLV-3440DM needs 1.5-2 minutes to boot up completely. • Configure the network settings of the device via front panel. • Make the settings of Receiver, Remux, Modulator and RF output step by step following the instruction written in the user manual. Accessories CD-ROM 1 PC BNC cable 1 PC AC Power cord 2 PC 75Ohm F type load 1 PC 25 Technical Specifications DVB-S/S2 Tuner Input (ISI Factory Optional) Connector Type Input Frequency Range Input Level Symbol Rate Roll Off Factor FEC Code Rate LNB Polarity Selection Voltage LNB Band Selection Tone Satellite Selection Command ISI ID DVB-C Tuner Input Connector Type Standard Input Frequency Input Level Symbol Rate Constellation Bandwidth Input Return Loss DVB-T/T2 Tuner Input Connector Type Standard Input Frequency Input Level Constellation 4×F type female 75Ω for Input EN 300 429, ITU J.83 Annex A, B, C 51~862MHz 45 ~ 95dBμV 16QAM, SR=6.875Msps 256QAM, SR=6.875Msps 1 ~ 7MBaud (ITU J.83 Annex A) 16QAM, 32QAM, 64QAM, 128QAM, 256QAM 6MHz, 7MHz, 8MHz 8dB (typ.) Input Return Loss 4×F type female 75Ω for Input EN 300 744(DVB-T), EN 302 755 (DVB-T2) 104 ~ 862MHz (VHF/UHF) -20 ~ -70dBm DVB-T: QPSK, 16QAM, 64QAM DVB-T2: QPSK, 16QAM, 64QAM, 256QAM 6MHz, 7MHz, 8MHz DVB-T: 2K, 8K DVB-T2: 1K, 2K, 4K, 8K, 16K, 32K DVB-T: 1/4, 1/8, 1/16, 1/32 DVB-T2: 1/4, 5/32, 1/8, 5/64, 1/16, 1/32, 1/64, 1/128 DVB-T: 1/2, 2/3, 3/4, 5/6, 7/8 DVB-T2: 1/2, 3/5, 2/3, 3/4, 4/5, 5/6 7dB (typ.) ASI Input Connector Type Standard Input Bit Rate 1×BNC female, 75Ω DVB-ASI, EN50083-9 ≤216Mb/s Bandwidth FFT Mode Guarding Interval FEC Code Rate Built-in Remux Number of Input Number of Output TS Input Management TS Output Management Service and PID Management PSI/SI 26 4×F type female 75Ω for Input 950 ~ 2150MHz -25 ~ -65dBm 2 -45MBaud’s DVB-S QPSK: 0.35 DVB-S2 8PSK: 0.35, 0.25, 0.2 DVB-S QPSK: 1/2, 2/3, 3/4, 5/6, 7/8 DVB-S2 QPSK: 1/2, 3/5, 2/3, 3/4, 4/5, 5/6, 8/9,9/10 DVB-S2 8PSK: 3/5, 2/3, 3/4, 5/6, 8/9, 9/10 0, 13V, 18V selectable 0/22KHz selectable DiSEqC 1.0 1 ~ 255 user configurable 9xMPTS/SPTS 5xMPTS/SPTS Demux and Remux among ASI, TS/IP and CI Inputs Remux for ASI output, TS/IP output and modulator Service and PID level for Remux, filtering and remapping PSI/SI table regeneration, NIT and SDT edition, LCN Edition and Re-generation En Descrambling Descrambler Common Interface BISS Mode DVB Common Scrambling Algorithm (CSA) 4 x PCMCIA slots, compatible with major CA CAMs in the market BISS-1, BISS-Ez QAM Modulation Standard of System Symbol Rate Constellation I/Q Amplitude Error I/Q Phase Error Phase Jitter MER ETSI EN300 492, ITU J.83, Annex A/C: 16/32/64/128/256QAM 2.5~6.99 Bauds 16QAM, 32QAM, 64QAM, 128QAM, 256QAM ≤ 0.1% ≤ 0.1% < 0.5°RMS 36dB min., 42dB typ. (with tester equalizer “off ” ) COFDM Modulation Standard of System Constellation Bandwidth FTT carrier number Guard Interval FEC rate MER ETSI EN 300 744 QPSK/16QAM/64QAM 5/6/7/8MHz 2K, 8K 1/4, 1/8, 1/16, 1/3216/32/64/128/256QAM 1/2, 2/3, 3/4, 5/6, 7/8 36dB min., 40dB typ. RF Output Interface Carrier Central Frequency Output Level Spurious Return Loss ASI Output Connector Type Standard Output Bit Rate Data Mode Package Length Signal Level ASI Output Source TS/IP Gigabit Ethernet (Duplex mode) Interface Physical Layer Standard Operation Mode Maximum Effective Bit Rate 1x F-type Female, 1x F-type Female(-20dB), 75Ωtype female 75Ω for loop through output 48~996MHz adjustable, step by 1 KHz 92-109dBμV@1 RF output enabled, 88-105dBμV@ 2 RF output enabled 85-102dBμV@3 RF output enabled, 83-100dBμV@ 4RF output enabled step by 1dBDVB-T: 2K/8K ≥50dBc typ. ≥12dB typ. 6x BNC female, 75Ω, DVB-ASI, EN50083-9 ≤ 200Mb/s Byte 188/204 Bytes 800±80mV ASI out 1-4: TS from Tuner 1 to 4 pass through (Descrambled) ASI 5-6: TS from Remux (mirrored) 1x RJ-45 IEEE 802.3, 10/100/1000 Base-T 1. Full-duplex: 1x multicast/unicast input and output; 2. Multi-channel Output: 5x multicast/unicast MPTS/SPTS output; 3. IPTV Output: 128x multicast/unicast output, unstuffed stream with video/audio only 1. Full-duplex: Input: 80Mbps, Output: 80Mbps 2. Multi-channel Output: 700Mbps 3. IPTV Output: 430Mbps 27 Data Encapsulation Other Protocols UDP, RTP Multicast/Unicast, IGMPv3,ARP Alarm Connector Type Switching Condition 1×D-sub 9 male User Defined Control & Monitoring Connector Type Remote Control 28 Local Control Serial Port Equipment Upgrade 1×RJ-45, 10/100 Base-T, for equipment IP Control SNMP, HTTP (Web Interface), Proprietary HDMS (Headend Device Management System) VFD display and 6-key keypad 1×RS-232 D-sub female, for debug use only Embedded FTP loader ,Telnet and http Physical Dimension Net Weight Power Supply Operating temperature Storage temperature Operating Humidity 505mm x 445mm x 45mm 3.2kg AC 90V ~ 250V, 50/60Hz 0 ~ 45°C -10 ~ 60°C 10 ~ 90%, non-condensed En Safety ! CAUTION Unauthorized maintenance or the use of non-approved replacements may affect the equipment specification and invalidate any warranties.The device should be kept away from electric, strong magnetic and hot areas (temperature < 40°C; humidity < 85%). Keep away from high electric and magnetic areas Don’t keep the device in the dusty, humid and high-temperature environment. Don’t let the petrol, thinner, insecticide or other volatile substances touch the shell of device. Please use soft cloth to wipe the device tenderly. Avoid eroding If the device is connected well with power and cables but the picture is still not good, please contact with the supplier or dealer. Please don’t dismantle the device or repair it by yourself. × Do not dimantel the device It is better to use the AC regulated power supply in the area where the voltage is unstable. ±10% 220~ The device must be grounded well. Device must be well grounded IDLV-5100P Professional Multi-format SD/HD Integrated Receiver Decoder Enter Power Tuner Lock Exit Alarm 29 Warranty, service and support This Limited Warranty applies only to the Product sold by Inverto Digital Labs, 18 Duchscherstrooss, L-6868 Wecker, Luxembourg (hereby, the “Company”) the Customer purchase for his own use and not for resale. The term “Product” in this Limited Warranty does not include any software programs, whether pre-loaded with the Product, installed subsequently or otherwise. 1. Disclaimer and exclusion except as specified in this limited warranty, the foregoing warranties are given and accepted in lieu of any and all other warranties or conditions, express or implied, including, but not limited to, the implied warranties or conditions of merchantability and fitness for a particular purpose. to the extent an express or implied warranty cannot be excluded in some states or juridictions, the above exclusion may not apply. in that event, such warranties are limited in duration to the warranty period. no warranties apply after that period. because some states or jurisdictions do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply. this limited warranty gives customer specific legal rights, and customer may also have other rights which vary from jurisdiction to jurisdiction. customer is advised to consult applicable state or country laws for a full determination of your rights. This disclaimer and exclusion shall apply even if the express warranty set forth below fails of its essential purpose. 2. Limitations of Liability Under no circumstances shall the Company or its supplier be liable for (a) damage to, or loss or corruption of programs, data or media, or (b) any damages whatsoever (including, but not limited to, direct or indirect damages, loss of business profits, lost savings or other special, incidental, exemplary or consequential damages whether for breach of warranty, contract, strict liability, tort) arising out of or resulting from the use of or inability to use the products and/or the enclosed written materials or the provision of or failure to provide support services, even if the Company, its supplier, an authorized Company representative, service provider or dealer have been advised of the possibility of such damages or of any claim by any third party. Any liability of the Company or its supplier which is not excluded shall be limited to the purchase price of the Product. Some jurisdictions do not allow the limitation of incidental or consequential damages so this limitation may not apply fully to the Customer, but such limitation shall apply to the maximum extent permitted by applicable law. 3. Application of the Warranty The Company warrants the Product against critical failure resulting from original manufacturing defects in workmanship or material, under normal use. The company does not warrant any uninterrupted or error-free operation of the product or that all deficiencies, errors, defects or nonconformities will be corrected. Unless the company specifies otherwise, this warranty extends only for the original user of the Product and the Warranty applies only in the country or region in which the original user purchases the Product to the Company or a Company Reseller in case of a resale. 4. Warranty period The warranty period of the Product is 24 months. The warranty period for the Product starts at the day of purchase (purchase invoice date) of the Customer, and in case of a resale by the Company Reseller not more than 45 days after the production date marked on the Product. This Limited Warranty extends only to the original end-user purchaser of the Product and is not transferable to anyone who obtains ownership of the Product from the original end-user purchaser. 5. Limited Warranty Exclusions This Warranty with respect to the Customer’s Product is subject to the following exclusions: (i) Failure or damage resulting from misuse (including but not limited to use of any Product capacity or capability, other than that authorized by the Company in writing), accident, modification, unsuitable physical or operating environment, or improper maintenance by the Customer; (ii) Failure caused by a Product for which the Company is not responsible; (iii) Any non-Company Products, including those provided with, or installed on, a Company Product at the Customer request; (iv) Accessories, supply items and consumables (e.g. batteries), and structural parts (e.g. frames and covers); (v) Service of Product alterations; (vi) Service of a Product on which the Customer is using capacity or capability, other than that authorized by the Company in writing; (vii) Any Product not manufactured by or for the Company, or sold to an end-user in a country not covered under this Warrant (viii) Loss of any, or damage to, programs, data, or storage media. The Company may opt to replace the Product 30 En submitted for warranty services and, thus, any data stored on the original Product may become permanently inaccessible. This Limited Warranty is voided by removal or alteration of identification labels on the Product or its parts. Any technical or other support provided for a Product under warranty, such as, “How to” questions and those regarding the product set-up and installation, is provided WITHOUT WARRANTIES OF ANY KIND. The Company is not liable for any transport/delivery/insurance costs, import duties, taxes, licensing fees and any charges from telephone/fax communication as consequence of the failure of the Product. 6. Service during the warranty period In the event the Product is found to be defective within the warranty period, Customer’s sole and exclusive remedy and the entire liability of the Company under this Limited warranty will be, at the Company or its Service Center, at its option: (1) Repair the Product by means of remote support such as, but not limited to, telephone, email support. (2) Upon the product return to the party supplying it to the Customer, freight an insurance prepaid - repair or replace any defective Product or parts of the Product thereof covered by the Warranty with new or factory-refurbished Products or parts that are equal to new products in performance. 7. To get the Limited Warranty service In the event that a warranty service is required, you should contact your specialist dealer or the point of sale. Warrantee claims cannot be made directly to the company - Inverto Digital Labs. You should therefore keep your sales receipt as proof of purchase. The Company recommends the Customer first utilize support material shipped with the product, product diagnostics, information contained on the Web, and online support on http://www.inverto. tv/support. If unsuccessful to obtain service under this warranty, the Customer must notify the Company Technical Support or its authorized Service Center representative of the defect before the expiration of the warranty period. Customers will provide appropriate assistance to the Telephone Support personnel to resolve issues. If the technical support is unsuccessful, The Company or its authorized Service representative will instruct the customer on how to receive warranty repair. If the Customer does not know of a Company authorized service center for the Company’s product, it should contact the reseller. If the reseller is an authorized service center, they will arrange for repair. If the Customer reseller is not a Company authorized Product’s service center, they will direct the customer to an authorized service center. The Company reserves the right to charge for service in exception cases. 8. Governing Law The Customer and the Company consent to the application of the laws of Luxembourg, to govern, interpret, and enforce all of the Customer and the Company’s rights, duties, and obligations arising from, or relating in any manner to, the subject matter of this Statement of Limited Warranty, without regard to conflict of law principles. 9. Jurisdiction All of our rights, duties, and obligations are subject to the courts of Luxembourg. 31 V210715