Preview only show first 10 pages with watermark. For full document please download

Iec Type Industrial Control Relays Tesys D-line, K-line, And Sk-line

   EMBED


Share

Transcript

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line SK-Line Ordering Information SK-Line Ordering Information – Miniature size saves space – Mounts on 35mm DIN3 track or can be mounted directly to a panel – Up to 4 poles Contact Configuration Control Circuit Supply Consumption Type of Termination CAZSK11G7 AC 4.2 VA DC Weight lb (kg) N/O N/C 1 1 CA2SK11 ▲ 0.24 (0.109) 2 0 CA2SK20 ▲ 0.24 (0.109) 1 1 CA3SK11 ▲ 0.24 (0.109) 2 0 CA3SK20 ▲ 0.24 (0.109) Catalog Number Weight lb (kg) Screw clamp 2.2 W Catalog Number Screw clamp Contact Adder Decks Used to expand the CA2SK20 two pole relays to a four pole relay. Contact Configuration Type of Termination LA1SK11 Screw clamp N/O N/C 2 0 LA1SK20 0.05 (0.022) 1 1 LA1SK11 0.05 (0.022) 0 2 LA1SK02 0.05 (0.022) Transient suppressor module LA4SKE1U Dampens the voltage spike that may occur when the relay coil is de-energized. The spike may adversely affect solid state equipment near the relay. The transient suppressor module snaps into a cavity located in the side of the relay. These modules can be used with CA2SK and CA3SK relays. Control Circuit Voltage Catalog Number Weight lb (kg) 24-48 V 50/60 Hz 24-48 Vdc LA4SKE1E 0.02 (0.010) 110-250 V 50/60 Hz 110-250 Vdc LA4SKE1U 0.02 (0.010) Coil Voltage Codes Voltage 12 24 36 48 110 120 220 230 240 380 400 480 50/60 Hz (CA2SK relays) — B7 — E7 F7 G7 M7 P7 U7 Q7 V7 T7 DC JD — CD ED SD — — — — — — — (CA3SK relays) ▲ Add proper voltage code to the end of the catalog number. 04/01 © 2001 Schneider Electric All Rights Reserved 19 IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line SK-Line Ordering Information Environment Type CA2 Conforming to Standards IEC337-1, 947-1, 947-5, NF C 63-140, VDE0660, BS4794 Approvals UL Listed File E164353 CCN NKCR, CSA File LR12721 Class 3211 03, SEMKO, SEV, DEMKO, CE Operating Temperature Range CA3 °F (°C) -4 to 131 (-20 to 55) Stranded wire AWG (mm2) Two #20 (0.75) to #16 (1.5) Solid wire AWG (mm2) Two #18 (1) to #14 (2.5) CA2 CA3 Conforming to UL508 Conforming to VDE 0110 Group C V V 600 660 600 660 V 24 to 600 12 to 220 Wire Range Control circuit characteristics Type Rated Insulation Voltage Rated Coil Voltage Uc Permissible Voltage Variation +10/-20% Uc Average Consumption Operating Time Mechanical Life Inrush 15.5 VA 2.2 W Sealed 4.2 VA 2.2 W Pick-up ms 8 to 16 10 to 18 Drop-out ms 6 to 8 4 to 6 10 10 In millions of operations Contact Ratings AC DC Inductive 35% PF Volts Resistive 75% PF Amps VA Make, Break & Cont. Amps Continuous Amps VA Continuous Amps Volts Amps Make 120 60 7200 6 720 10 10 24 3 240 30 7200 3 720 10 10 60 2 15 7200 1.5 720 10 10 110 0.8 12 7200 1.2 720 10 10 240 0.2 UL Rating A600 480 600 Break Approximate dimensions Contact Configurations Contact adder decks 33 NO 41 NC 31 NC 41 NC 34 42 32 42 21 NC 22 2 N/C 43 NO 13 NO 14 1 N/O and 1 N/O 44 23 NO 22 20 2 N/O 33 NO 13 NO 1 N/O and 1 N/C 14 2 N/O 34 Relays © 2001 Schneider Electric All Rights Reserved 04/01