IES INDOOR REPORT PHOTOMETRIC FILENAME : PANEL1X4-34YN-D10 - ITL78949MOD.IES DESCRIPTION INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST]SCALED FROM ITL78949 [TESTLAB]SCALED PHOTOMETRY [ISSUEDATE]09/20/13 [MANUFAC]RAB LIGHTING, INC. [LUMCAT]PANEL1X4-34YN/D10(0-10V DIMMING DRIVER) [LUMINAIRE]FABRICATED WHITE PAINTED METAL HOUSING, 2 WHITE CIRCUIT [MORE]BOARDS EACH WITH 120 LEDS, FROSTED HOLOGRAPHIC PLASTIC LENS. [MORE]LENS FROSTED SIDE UP. [LAMP]TWO HUNDRED FORTY WHITE LIGHT EMITTING DIODES (LEDS), VERTICAL [MORE]BASE-UP POSITION. [OTHER]TOTAL INPUT WATTS = 36.0 AT 120.0 VOLTS [_MOUNTING]RECESSED [_LEDDRIVER]RAB RD-042-A0700-C [_NOTE]DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED AT RATED INPUT [MORE]VOLTAGE (120VAC, 60Hz) TO THE LED DRIVER. [OTHER]TEST PROCEDURE: IESNA LM-79-08 [OTHER]TEST DISTANCE = 35.0 FEET [_ABSOLUTELUMENS]2995 CHARACTERISTICS Lumens Per Lamp Total Lamp Lumens Luminaire Lumens Total Luminaire Efficiency Luminaire Efficacy Rating (LER) Total Luminaire Watts Ballast Factor CIE Type Spacing Criterion (0-180) Spacing Criterion (90-270) Spacing Criterion (Diagonal) Basic Luminous Shape Luminous Length (0-180) Luminous Width (90-270) Luminous Height
N.A. (absolute) N.A. (absolute) 2995 N.A. 83 36 1.00 Direct 1.22 1.22 1.34 Rectangular 3.84 ft 0.84 ft 0.00 ft
Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file.
Page 1
IES INDOOR REPORT PHOTOMETRIC FILENAME : PANEL1X4-34YN-D10 - ITL78949MOD.IES LUMINANCE DATA (cd/sq.m) Angle In Degrees
Average 0-Deg
Average 45-Deg
Average 90-Deg
45 55 65 75 85
3337 3120 2845 2376 1308
3293 3066 2787 2336 1348
3244 3017 2722 2282 1348
Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file.
Page 2
IES INDOOR REPORT PHOTOMETRIC FILENAME : PANEL1X4-34YN-D10 - ITL78949MOD.IES CANDELA TABULATION
0.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 22.5 25.0 27.5 30.0 32.5 35.0 37.5 40.0 42.5 45.0 47.5 50.0 52.5 55.0 57.5 60.0 62.5 65.0 67.5 70.0 72.5 75.0 77.5 80.0 82.5 85.0 87.5 90.0
0.0 1139.468 1137.400 1133.264 1127.060 1115.686 1103.278 1087.768 1069.156 1046.408 1021.592 993.674 963.688 932.668 898.546 864.424 826.166 788.942 747.582 706.222 664.862 621.434 578.006 535.612 491.150 447.722 403.260 359.832 315.370 270.908 227.480 184.052 142.692 103.400 66.176 34.122 10.340 0.000
22.5 1139.468 1134.298 1130.162 1122.924 1113.618 1100.176 1083.632 1063.986 1041.238 1016.422 989.538 959.552 927.498 894.410 857.186 819.962 782.738 742.412 701.052 660.726 617.298 574.904 532.510 489.082 444.620 400.158 356.730 313.302 268.840 225.412 183.018 141.658 102.366 66.176 35.156 11.374 0.000
45.0 1139.468 1138.434 1134.298 1127.060 1115.686 1102.244 1085.700 1066.054 1042.272 1017.456 989.538 959.552 926.464 892.342 856.152 817.894 779.636 738.276 696.916 657.624 614.196 569.734 526.306 483.912 440.484 396.022 352.594 309.166 265.738 222.310 180.950 139.590 101.332 66.176 35.156 12.408 0.000
67.5 1139.468 1138.434 1134.298 1126.026 1114.652 1100.176 1083.632 1063.986 1039.170 1014.354 984.368 954.382 922.328 887.172 849.948 811.690 772.398 731.038 690.712 649.352 605.924 563.530 520.102 477.708 434.280 390.852 347.424 303.996 260.568 219.208 177.848 138.556 100.298 65.142 34.122 12.408 0.000
90.0 1139.468 1135.332 1130.162 1122.924 1111.550 1097.074 1079.496 1058.816 1037.102 1010.218 981.266 950.246 917.158 883.036 845.812 807.554 769.296 727.936 686.576 645.216 602.822 560.428 518.034 474.606 431.178 387.750 344.322 301.928 259.534 217.140 176.814 138.556 100.298 65.142 35.156 13.442 0.000
Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file.
Page 3
IES INDOOR REPORT PHOTOMETRIC FILENAME : PANEL1X4-34YN-D10 - ITL78949MOD.IES ZONAL LUMEN SUMMARY Zone
Lumens
%Lamp
%Fixt
0-20 0-30 0-40 0-60 0-80 0-90 10-90 20-40 20-50 40-70 60-80 70-80 80-90 90-110 90-120 90-130 90-150 90-180 110-180 0-180
413.14 868.02 1402.42 2410.54 2950.54 2994.94 2887.4 989.28 1526.7 1356.67 540.00 191.44 44.41 0.00 0.00 0.00 0.00 0.00 0.00 2994.94
N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A.
13.80 29.00 46.80 80.50 98.50 100.00 96.40 33.00 51.00 45.30 18.00 6.40 1.50 0.00 0.00 0.00 0.00 0.00 0.00 100.00
Total Luminaire Efficiency = N.A.% ZONAL LUMEN SUMMARY Zone
Lumens
0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100 100-110 110-120 120-130 130-140 140-150 150-160 160-170 170-180
107.54 305.59 454.88 534.40 537.42 470.70 348.55 191.44 44.41 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file.
Page 4
IES INDOOR REPORT PHOTOMETRIC FILENAME : PANEL1X4-34YN-D10 - ITL78949MOD.IES COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD Effective Floor Cavity Reflectance 0.20 RC RW
80 70 50 30 10
70 70 50 30 10
50 50 30 10
30 50 30 10
10 50 30 10
0 0
0 1 2 3 4 5 6 7 8 9 10
119 119 119 119 109 104 100 97 99 91 85 79 91 80 72 66 83 71 63 56 77 64 55 48 71 58 49 42 66 52 44 38 61 48 39 34 57 44 36 30 54 41 33 27
116 116 116 116 106 102 98 95 97 89 83 78 88 79 71 65 81 70 62 56 74 63 54 48 69 57 48 42 64 51 43 37 60 47 39 33 56 43 35 30 52 40 32 27
111 111 111 98 95 92 86 81 76 76 69 64 68 60 55 61 53 48 55 47 42 50 42 37 46 38 33 42 35 30 39 32 27
106 106 106 94 91 89 83 78 74 73 68 63 65 59 54 59 52 47 53 47 41 48 42 37 44 38 33 41 35 30 38 32 27
102 102 102 90 88 86 80 76 73 71 66 62 63 58 53 57 51 47 52 46 41 47 41 37 43 37 33 40 34 30 37 31 27
100 84 71 60 51 44 39 35 31 28 25
Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file.
Page 5
IES INDOOR REPORT PHOTOMETRIC FILENAME : PANEL1X4-34YN-D10 - ITL78949MOD.IES POLAR GRAPH
1139
855
570 2 285
1
Maximum Candela = 1139.468 Located At Horizontal Angle = 0, Vertical Angle = 0 # 1 - Vertical Plane Through Horizontal Angles (0 - 180) (Through Max. Cd.) # 2 - Horizontal Cone Through Vertical Angle (0) (Through Max. Cd.)
Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file.
Page 6
®
NVLAP LAB CODE: 200925-0
INDEPENDENT TESTING LABORATORIES, INC. 4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA E-MAIL:
[email protected] • WEBSITE: www.itlboulder.com Page 1 of 4
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303)442-1255
REPORT NUMBER: DATE: PREPARED FOR: CATALOG NUMBER:
• FAX: (970)535-3114 ITL78952 09/27/13 RAB LIGHTING, INC. PANEL1X4-34YN
•
ADDRESS:
170 LUDLOW AVE NORTHVALE, NJ 07647
LUMINAIRE:
FABRICATED WHITE PAINTED METAL HOUSING, 2 WHITE CIRCUIT BOARDS EACH WITH 120 LEDS, FROSTED HOLOGRAPHIC PLASTIC LENS. LENS FROSTED SIDE UP.
LAMP:
TWO HUNDRED FORTY WHITE LIGHT EMITTING DIODES (LEDS), VERTICAL BASE-UP POSITION.
DRIVER:
RAB RD-042-A0700N
NOTE:
DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED AT RATED INPUT VOLTAGE (120.0 AND 277.0 VAC, 60Hz) TO THE LED DRIVER. Calibration Due: Associated Power Technologies APT5040 AC Power Source N/A Yokogawa WT210 Digital Power Meter #6 09/24/13 Ocean Optics QE65000 Spectroradiometer 03/16/14 ITL 2.0m Diameter Integrating Sphere S20-2, 4PI Geometry 03/16/14
INSTRUMENTS:
OBJECT OF TEST:
Measure the Total Radiant Flux*, Spectral Power Distribution (SPD), Correlated Color Temperature (CCT), Color Rendering Indices (CRIa,1-14), Chromaticity Coordinates (x,y; u’v’), ANSI C78.377 Duv, and electrical data including ANSI C82.77-2002 Power Factor (PF) and Total Harmonic Distortion (THD) to the test sample. Report Off-State Power. Measure electrical data including Total Harmonic Distortion (THD) at maximum rated voltage.
PROCEDURE:
The test sample was provided by the customer and had an unknown number of operating hours. The test sample was mounted inside the integrating sphere and allowed to stabilize. After stabilization occurred, measurements were taken. In order to measure mean performance, multiple data sets were recorded and averaged. Readings were taken with the test sample operating at 120.0 VAC input. Electrical data was also recorded at maximum nominal rated input voltage (277.0 VAC). All testing performed in a 25 +/-1 degree Celsius free air ambient and in accordance with IESNA LM-79-08. All data are traceable to the National Institute of Standards and Technology. Off-State Power was reported with no voltage applied to the sample.
*NOTE:
Proper calibration of integrating spheres for measuring total flux output of non-directional samples will produce reliable, repeatable results within the calibration tolerances of the equipment used. However, measurement of test samples with significant self absorption and/or directional output, even when these effects are compensated for, are likely to have a greater variation in results compared to the flux output calculated from a goniophotometric exploration since these artifacts do not affect the goniophotometric results.
RESULTS:
(continued subsequent pages)
THIS ITL REPORT WITH THE USE OF THE NVLAP LOGO SHALL NOT BE USED BY THE CLIENT TO CLAIM PRODUCT CERTIFICATION, APPROVAL, OR ENDORSEMENT BY NVLAP, NIST, OR ANY AGENCY OF THE FEDERAL GOVERNMENT.
Checked Approved
P O’CONNOR L GRABA Lighting Engineer
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
INDEPENDENT TESTING LABORATORIES, INC. 4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA E-MAIL:
[email protected] • WEBSITE: www.itlboulder.com Page 4 of 4
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303)442-1255
REPORT NUMBER: DATE: PREPARED FOR: CATALOG NUMBER:
• FAX: (970)535-3114 ITL78952 09/27/13 RAB LIGHTING, INC. PANEL1X4-34YN
•
CIE Chromaticity Diagram
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
INDEPENDENT TESTING LABORATORIES, INC. 4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA E-MAIL:
[email protected] • WEBSITE: www.itlboulder.com Page 2 of 4
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303)442-1255
REPORT NUMBER: DATE: PREPARED FOR: CATALOG NUMBER:
• FAX: (970)535-3114 ITL78952 09/27/13 RAB LIGHTING, INC. PANEL1X4-34YN
•
RESULTS: SPECTRORADIOMETRIC Observer Chromaticity Ordinate x Chromaticity Ordinate y Observer Chromaticity Ordinate u’ Chromaticity Ordinate v’ Correlated Color Temp CCT (K) ANSI C78.377-2008 Duv Total Radiant Flux (milliWatts)
CIE 1931 2 degree 0.3977 0.3895 CIE 1976 2 degree 0.2313 0.5096 3662 0.001 9173 *
ELECTRICAL Input Voltage (Volts AC) Input Current (Amps AC) Input Power (Watts) Input Power Factor (%) Input Current THD (%) Input Voltage THD (%)
120.0 0.290 34.6 99.4 8.0 0.1
Off-State Power (Watts)
0.0
ELECTRICAL AT MAX NONIMAL INPUT Input Voltage (Volts AC) Input Current (Amps AC) Input Power (Watts) Input Power Factor (%) Input Current THD (%) Input Voltage THD (%)
*NOTE:
COLOR RENDERING INDICES Ra (Average 1-8) R1 Light greyish red R2 Dark greyish yellow R3 Strong yellowish green R4 Moderate yellowish green R5 Light bluish green R6 Light blue R7 Light violet R8 Light reddish purple R9 Strong red R10 Strong yellow R11 Strong green R12 Strong blue R13 Light yellowish pink (skin) R14 Moderate olive green (leaf)
CRI 85 83 90 95 83 83 86 89 70 26 75 81 62 85 97
277.0 0.134 35.0 94.3 9.3 0.1
Proper calibration of integrating spheres for measuring total flux output of non-directional samples will produce reliable, repeatable results within the calibration tolerances of the equipment used. However, measurement of test samples with significant self absorption and/or directional output, even when these effects are compensated for, are likely to have a greater variation in results compared to the flux output calculated from a goniophotometric exploration since these artifacts do not affect the goniophotometric results.
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
INDEPENDENT TESTING LABORATORIES, INC. 4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA E-MAIL:
[email protected] • WEBSITE: www.itlboulder.com Page 3 of 4
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303)442-1255
REPORT NUMBER: DATE: PREPARED FOR: CATALOG NUMBER:
• FAX: (970)535-3114 ITL78952 09/27/13 RAB LIGHTING, INC. PANEL1X4-34YN
•
RESULTS: Wavelength 380 385 390 395 400 405 410 415 420 425 430 435 440 445 450 455 460 465 470 475 480 485 490 495 500 505 510
mW per nm 0.229 0.228 0.232 0.247 0.285 0.364 0.546 0.940 1.704 3.165 5.788 10.061 17.028 29.134 42.439 43.466 33.108 25.479 20.990 16.826 14.630 14.659 15.877 18.055 20.948 24.030 26.817
Wavelength 515 520 525 530 535 540 545 550 555 560 565 570 575 580 585 590 595 600 605 610 615 620 625 630 635 640 645
mW per nm 29.274 31.358 33.161 34.742 36.137 37.628 39.095 40.572 41.953 43.432 44.772 46.031 47.139 48.002 48.734 49.237 49.552 49.582 49.205 48.597 47.573 46.266 44.658 42.825 40.703 38.314 35.860
Wavelength 650 655 660 665 670 675 680 685 690 695 700 705 710 715 720 725 730 735 740 745 750 755 760 765 770 775 780
mW per nm 33.289 30.701 28.090 25.562 23.113 20.754 18.590 16.546 14.653 12.921 11.351 9.944 8.654 7.527 6.515 5.637 4.871 4.214 3.639 3.145 2.711 2.338 2.013 1.736 1.495 1.286 1.112
Output vs. Wavelength
52.5
Output (mW/nm)
42.0
31.5
21.0
10.5
0.0 380.0
420.0
460.0
500.0
540.0 580.0 620.0 Wavelength (nm)
660.0
700.0
740.0
780.0
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.