Preview only show first 10 pages with watermark. For full document please download

Ies Indoor Report Photometric Filename : S82-led

   EMBED


Share

Transcript

IES INDOOR REPORT PHOTOMETRIC FILENAME : S82-LED-DI-1U-1D-FCA.IES DESCRIPTION INFORMATION (From Photometric File) IESNA:LM-63-2002 [TESTLAB] Photopia 3.2.11 see: www.ltioptics.com/ies [ISSUEDATE] [TEST] 1 [TESTDATE] Thu May 16 13:14:11 2013 [MANUFAC] PMC LIGHTING [LUMINAIRE] S82-LED-DI-1U-1D-FCA [LAMP] LED 20.16W 22" board w/ 54 LEDs (700mA) (core only) [LAMPCAT] 162-1330700 CHARACTERISTICS Lumens Per Lamp Total Lamp Lumens Luminaire Lumens Total Luminaire Efficiency Luminaire Efficacy Rating (LER) Total Luminaire Watts Ballast Factor CIE Type Spacing Criterion (0-180) Spacing Criterion (90-270) Spacing Criterion (Diagonal) Basic Luminous Shape Luminous Length (0-180) Luminous Width (90-270) Luminous Height 2000 (4 lamps) 8000 6995 87 % 79 88.704 1.00 General Diffuse N.A. N.A. N.A. Rectangular w/Sides 4.01 ft 0.67 ft 0.19 ft LUMINANCE DATA (cd/sq.m) Angle In Degrees Average 0-Deg Average 45-Deg Average 90-Deg 45 55 65 75 85 4388 3859 3158 2237 886 3343 2541 1766 965 340 2760 1955 1296 713 327 Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. Page 1 IES INDOOR REPORT PHOTOMETRIC FILENAME : S82-LED-DI-1U-1D-FCA.IES CANDELA TABULATION 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 0.0 1200.90 1185.79 1182.59 1169.57 1152.69 1107.64 1068.50 992.95 909.28 807.60 698.89 587.48 479.80 365.66 263.19 169.59 86.82 29.72 12.81 109.30 226.04 334.10 444.12 546.90 641.35 736.87 827.18 905.73 972.86 1048.68 1100.46 1154.29 1192.12 1215.68 1249.37 1254.07 1263.25 22.5 1200.90 1192.93 1181.86 1176.39 1157.77 1119.59 1062.54 987.85 896.25 790.43 681.18 559.42 451.57 335.36 242.45 149.52 74.32 25.50 13.32 110.21 223.58 334.15 441.53 545.37 640.58 735.52 822.58 903.30 976.01 1045.49 1097.41 1155.72 1193.37 1214.05 1250.55 1251.72 1263.25 45.0 1200.90 1202.12 1183.80 1172.14 1142.22 1097.90 1036.85 947.57 840.69 726.88 606.03 485.15 379.94 280.05 193.34 117.18 59.00 27.37 12.43 108.47 221.81 333.07 438.70 538.81 639.48 730.23 822.35 897.63 975.43 1038.45 1096.10 1151.24 1189.31 1224.48 1257.46 1249.38 1263.25 67.5 1200.90 1184.53 1194.29 1169.98 1131.71 1090.56 1008.00 902.52 790.70 654.33 526.77 415.82 318.76 231.91 162.02 99.01 56.73 30.38 9.59 109.56 218.72 329.04 434.13 537.46 635.10 726.82 816.70 895.57 971.99 1036.35 1093.11 1149.31 1189.76 1218.66 1236.24 1266.63 1263.25 90.0 1200.90 1187.26 1167.44 1166.73 1146.58 1080.92 992.00 890.27 755.10 624.73 498.86 393.35 301.33 220.28 153.38 95.24 57.22 30.45 8.68 109.29 215.84 327.73 434.35 537.77 630.66 729.02 815.06 895.98 969.75 1039.06 1097.31 1149.13 1186.43 1222.89 1246.93 1278.51 1263.25 Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. Page 2 IES INDOOR REPORT PHOTOMETRIC FILENAME : S82-LED-DI-1U-1D-FCA.IES ZONAL LUMEN SUMMARY Zone Lumens %Lamp %Fixt 0-20 0-30 0-40 0-60 0-80 0-90 10-90 20-40 20-50 40-70 60-80 70-80 80-90 90-110 90-120 90-130 90-150 90-180 110-180 0-180 444.25 949.99 1539.24 2535.18 2957.41 2993.83 2880.26 1094.99 1651.96 1282.1 422.23 136.08 36.41 472.25 1006.8 1660.75 3006.00 4000.97 3528.72 6994.79 5.60 11.90 19.20 31.70 37.00 37.40 36.00 13.70 20.60 16.00 5.30 1.70 0.50 5.90 12.60 20.80 37.60 50.00 44.10 87.40 6.40 13.60 22.00 36.20 42.30 42.80 41.20 15.70 23.60 18.30 6.00 1.90 0.50 6.80 14.40 23.70 43.00 57.20 50.40 100.00 Total Luminaire Efficiency = 87.40% ZONAL LUMEN SUMMARY Zone Lumens 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100 100-110 110-120 120-130 130-140 140-150 150-160 160-170 170-180 113.57 330.67 505.74 589.25 556.97 438.97 286.16 136.08 36.41 122.95 349.30 534.55 653.95 694.36 650.89 530.21 344.93 119.82 Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. Page 3 IES INDOOR REPORT PHOTOMETRIC FILENAME : S82-LED-DI-1U-1D-FCA.IES COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD Effective Floor Cavity Reflectance 0.20 RC RW 80 70 50 30 10 70 70 50 30 10 50 50 30 10 30 50 30 10 10 50 30 10 0 0 0 1 2 3 4 5 6 7 8 9 10 92 84 77 70 64 59 55 50 47 44 41 84 77 70 64 59 54 50 46 43 40 37 69 61 54 48 43 38 34 31 28 26 24 56 50 44 39 35 31 28 26 24 22 20 43 39 34 31 28 25 23 21 19 18 16 37 32 27 23 20 18 16 14 12 11 10 92 81 71 62 55 49 44 40 36 33 30 92 78 66 56 49 42 37 33 30 27 24 92 75 61 51 44 37 32 28 25 22 20 84 74 65 57 51 45 41 37 34 31 28 84 71 61 52 45 39 35 31 28 25 23 84 69 57 48 41 35 30 27 24 21 19 69 59 51 44 38 34 30 27 24 22 20 69 58 48 41 35 30 26 23 21 18 17 56 48 42 36 32 28 25 22 20 18 17 56 47 40 34 29 25 22 20 18 16 14 43 38 33 29 25 23 20 18 16 15 14 Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. 43 37 32 27 24 21 18 16 15 13 12 Page 4 IES INDOOR REPORT PHOTOMETRIC FILENAME : S82-LED-DI-1U-1D-FCA.IES POLAR GRAPH 1279 959 639 320 3 2 1 Maximum Candela = 1278.51 Located At Horizontal Angle = 90, Vertical Angle = 175 # 1 - Vertical Plane Through Horizontal Angles (90 - 270) (Through Max. Cd.) # 2 - Vertical Plane Through Horizontal Angles (45 - 225) # 3 - Vertical Plane Through Horizontal Angles (0 - 180) Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. Page 5