Transcript
IFT 6330-12 Series 12-Bay ATA RAID Subsystem
SCSI-to-ATA Fibre-to-ATA OVERVIEW
The IFT-6330 12-bay rackmount subsystem supports SCSI-to-ATA and Fibre-to-ATA solutions. It is an ideal alternative to SCSI or Fibre RAID subsystems with the same protection to data and high performance.
IFT 7250F
12-Bay RAID Controller
7250F-12U3D
7250F-12F2D
The IFT-7250F RAID controller inside the 6330 subsystem is powered by Infortrend's proprietary ASIC featuring a 133MHz memory bus and two 64-bit, 66MHz PCI buses around its XOR engine. Calculation of parity and distribution of data can be processed in parallel at raging speed among CPU, memory, and drives. Advanced firmware algorithms and the L2-enabled CPU further accelerate IO turnarounds in term of the reduced response time and optimized access patterns. The IFT-6330 supports massive capacity with 12 hot-swappable trays in a standard 19-inch equipment rackmount enclosure.
MODELS SUBSYSTEM 6330-12U3D 6330-12F2D
HOST CHANNEL Dual Ultra160 Dual 2G Fibre
BOARD-ONLY 7250F-12U3D 7250F-12F2D
HOST CHANNEL Dual Ultra160 Dual 2G Fibre
2G FC MODULE IFT-9237D
Dual channel converter board; 3-pin to SFP Link cable: IFT-9221RF23P
SYSTEM BACKPLANE 9230A-3UB12
Supported RAID levels are: 0, 1 (0+1), 3, or 5. Except RAID level 0, the system allows one HDD failure without impact on the existing data and failed drive rebuild is transparent to the host. System operation is constantly protected by redundant cooling fans and power supplies. System information is easily accessible via the control panel, RAIDGuide Manager, or VT100 terminal emulation.
KEY FEATURES ! ! !
! ! ! ! ! ! ! ! ! !
! ! ! ! ! !
PowerPC 64-bit high frequency CPU with 256KB embedded L2 cache 128/256/512MB SODIMM cache memory available, addressable to 1GB Two Ultra160-Wide LVD SCSI ports; Sustained Transfer rate up to 160MB/sec for each OR One or Two 2Gbps FC Fibre Channel; Sustained Transfer rate up to 200MB/sec for each Support 12 ATA-133 hard drives Supports 3.5" x 1" high ATA drives RAID levels: 0, 1 (0+1), 3, 5 Multiple Logical Drive configurations and each with a different RAID level Auto rebuild, hot spare, and hot swap capability Online expansion Configurable optimization mode: ransom or sequential Built-in RTC (Real Time Clock) Multi-host support Bad Block Handling: for managing bad blocks during rebuild and the manual Media Scan function for drive maintenance User-friendly RAIDGuide GUI Manager on Window 2000 and NT VT100 terminal emulation for system setup and status report through a serial port 350W Redundant and hotswappable power supplies Redundant cooling fans 3U 19" rackmount enclosure Controller kit for SI/ODM's building a 12-bay RAID subsystem
High Performance
Amply equipped with a 64-bit 133MHz memory bus and two independent PCI buses, the subsystem incorporates Infortrend's proprietary ASIC with a state-of-the-art, 64-bit PowerPC
processor. The load-balanced bus bandwidth makes the subsystem's high data throughput more than sufficient for small-to-medium sized servers or workstations. Data In/Out can be distributed at the burst rate up to 533MB/sec between the host and devices, and the system's overall sustained performance reaches 200MB/sec (reads with two 2Gbps Fibre).
The dual independent PCI bus design virtually eliminates all imminent bottlenecks on IO traffic, providing sufficient throughput for a wide range of applications on Disk-to-Disk Backup, CCTV storage, VOD, SCSI-based PCs, single-user workstations, NT, Linux, or Unix-based servers.
High Data Availability
The system provides full-featured RAID protection in the levels of 0, 1 (0+1), 3, and 5. Data availability is guaranteed by a long list of sophisticated firmware functions: dedicated/global hot spares, remote and real-time monitoring, automatic drive failure detection, automatic failed drive rebuild, and online expansion.
RAIDGuide Manager
RAIDGuide is an easy-to-use, Java-based GUI RAID management software designed specifically for use with Infortrend's SCSI-to-ATA and Fibre-to-ATA RAID subsystems and controller boards. Operating under Java 2.0 (Java Run-time Environment 1.2 or 1.3), RAIDGuide provides a complete management interface to the disk array and a constant real-time report of the current RAID status, errors, events, and capacity. RAIDGuide permits ATA RAID managers to quickly locate and rectify problematic hardware without downtime or data loss. Many RAID controller functions, such as password management and firmware upgrades can be handled through the software console. The information window provides information about all installed hard drives and the key elements of the RAID controller such as cache size.
Controller environmental conditions and current cache data status window, and RAID manual and auto setup, and RAID expansion are also supported from within RAIDGuide. RAID managers can be notified of events occurred at virtually anywhere by the powerful event notification utility, NPC (Notification Processing Center). A variety of notification methods are available: e-mail, SNMP traps, LAN broadcast, fax, and pager. RAIDGuide makes array management an easy matter of point-and-click from the local host via Java-enabled browser.
Bad Block Handling
The occurrence of bad blocks on more than one drive usually leads to unrecoverable loss of data. To prevent data loss by this situation, two options are implemented: "Media Scan" and "Bad Block Handling in Degrade Mode." The Media Scan can be performed regularly to examine drives and data can be reconstructed onto good sectors if any bad blocks found during the process. If bad blocks are encountered on yet another drive during the rebuild process, the block LBA (Logical Block Address) of those bad blocks will be indicated and the rebuild process can continue with the unaffected sectors, salvaging most of your precious data. Special algorithms have been implemented to ensure system performance when drives are being scanned.
SAN Ability
The LUN filtering function is available for controlling access to data in SAN environments. Up to 128 filter entries are supported and multiple entries can be mapped to each logical unit. Various functions; like host port auto-identification, filter type selection, entry naming, and access mode configuration; make setting the shared storage an easier task.
Redundant Power Supply
Two 350W, hot-swappable power supplies provide fault-tolerance to power source. With two power supplies installed, both will share the current consumption needs of the whole system. If one should fail, an alarm will sound and the remaining power supply will take over the full load until the faulty unit is replaced. The hot-swap feature ensures that the system remains operational while replace-
ment is taking place. Power-supply modules are equipped with their own independent cooling fans.
Cooling Fan
Two cooling fans are installed for drive and controller cooling. The cooling fans can adjust the RPM through various temperature. The system's ventilation is from front to back. Specially designed airflow passages dissipate heat from the hard disks and the controller.
Enclosure Fault Management
The system can monitor the operating status of enclosure components, including that of fans, power supplies, and disk drives. Component failures are locally indicated on the LCD control panel, by the sounding alarm, or through the RAIDGuide manager software. The RAIDGuide's sub-module, NPC, can be used to notify system administrators remotely via e-mail, pager, fax, SNMP traps, or LAN broadcast.
sophisticated features, including environmental monitoring and fault management, can be easily integrated into SI/ODM systems. Modular ATA backplanes (with 1" drive pitch) and daughterboard options for different host types are available along with the controller board.
SUBSYSTEM SPARE PARTS
In order to facilitate customer service, Infortrend makes spare parts available for ATA subsystems: Power Supply module: IFT-9211R12
Cooling Fan: IFT-9212B & IFT-9212
Setup and Status Monitoring
The system will automatically initialize based on the number of disk drives installed at start up. Manual configuration and monitoring can be done through the LCD control panel. The firmware also contains an embedded management program that can be accessed using a VT100 terminal connected to the RS-232C port. The later is a convenient platformindependent management utility.
IFT-7250F CONTROLLER BOARD (SI/ODM Solution)
An OEM board only solution - IFT7250F controller is available for customers who design their own enclosure and want to take full advantage of the SCSI-to-ATA or Fibre-to-ATA controller's advanced functionality. The controller's
Drive Tray: IFT-9215/30
Note: each of these spare parts items may have a minimum order requirement.
SPECIFICATIONS Controller
! PowerPC 750CXe processor with 256KB embedded L2 cache ! Infortrend Proprietary IFT-500133 ASIC with XOR engine ! Standard 128MB cache memory in one SODIMM, ECC supported ! Other available memory sizes are 256MB and 512MB ! 12 ATA channels ! LCD controller panel interface ! System Fan speed/Voltage/Temperature selfmonitoring ! One RS232 serial port ! 32KB NVRAM with RTC (Real Time Clock) ! Beeper
Host Interface SCSI ! ! ! ! !
Physical / Electrical
Drive Interface
Dual port Ultra160 LVD SCSI Transfer rate up to 160Mbytes/sec Concurrent I/O command Tagged Command Queuing Automatic bad-sector reassignment
External Connection
! ATA-100, 133 applicable ! 12 hot-swap drive bays
* Four 68-pin SCSI, daisy chain capable connectors for two host SCSI ports, OR,Two SFP ports for dual channel Fibre connection * One DB-9 connector for RS232C serial port (38400, n, 8,1) * One RJ45 connector for 10/100Mb Ethernet
RAID Operation ! ! ! ! ! ! !
RAID level 0, 1 (0+1), 3 and 5 Multiple RAID selection Hot-spare drive operation Drive hot-swapping Automatic background rebuild Online drive expansion Bad block handling
Controls / Indicators
! Front LCD control panel for setup and configuration ! 3 drive LED indicators: power, busy, and attention ! Power and drive failure indication through LCD ! Built-in beeper / alarm mute button
Power Supply 2 redundant hot-swappable power supplies with PFC Input 90-260VAC, 47-63Hz Output @5V (20A max), 12V (25A max), 350 watts Cooling Fan
2 thermal fans in two separate modules, 12cm, 12V, 0.41A, 0 2250rpm, 36.8dbA at 30 C 9.2cm, 12V, 0.23A, 2600rpm, 0 35dbA at 30 C
Operating Temperature
5 to 40 C
Relative Humidity
10-95%, non-condensing
Altitude
Sea level to 10,000 ft
Management Software
! RAIDGuide manager software for Windows 2000 / NT via in-band SCSI or in-band Fibre ! Firmware-embedded manager via RS-232C (platform independent)
Fiber Channel
! Two 2Gbps Fiber channels ! LUN Filtering for access control
C
U R
0
US
LISTED E185623
Dimensions Rackmount SI/ODM controller board only:
System Weight (w/o drives) System dimensions(inches) 5.34H x 18.9W x 24.4D inches (rackmount configuration - 19" equipment cabinet size) board dimensions: 7.4L x5.82W x 0.98H inches
North and South America Santa Clara Offices 3150 Coronado Drive Santa Clara, CA 95054, USA Tel: (408) 988-5088 Fax: (408) 988-6288
[email protected] [email protected] http://www.infortrend.com
Asia Pacific Infortrend Technology, Inc. 8F, No. 102 Chung-Shan Rd., Sec. 3 Chung-Ho City, Taipei Hsien, Taiwan Tel: (886)-2-2226-0126 Fax: (886)-2-2226-0020
[email protected] [email protected] http://www.infortrend.com.tw
Packed in carton 30.7"H x 23.42"W x 16.92"D
Net weight 28.1Kg
China Infortrend Technology, Ltd. Room 1236, 12F, Tower C, Corporate Square, No. 35 Financial Street Xicheng District, Beijing, China 100032 Tel: (86)-10-88091540 Fax: (86)-10-88092126
[email protected] [email protected] http://www.infortrend.com.cn
Packed in carton 30.1Kg
Europe Infortrend Europe Limited Ground Floor, Chancery House St. Nicholas Way, Sutton Surrey, SM1 1JB, UK Tel:+44-(0)20 8770 1838 Fax:+44-(0)20 8770 7409
[email protected] [email protected] http://www.infortrend-europe.com
* Quality is our priority and we back it with a 3 year warranty for the RAID controller and 1 year warranty for enclosure components. * Specifications are subject to change without prior notice. * IFT-6330, IFT-7250F, and RAIDGuide are trademarks of Infortrend Technology, Inc. * Other trade names and trademarks belong to their respective owners. Bro-6330-12-0303 MAR. 2003
FCC certified