Transcript
iGigaSwitch 16XX E+ family Managed industrial Ethernet switches 16 port switches family • • • •
Up to 12x PoE+ ports according to IEEE 802.3at with 360W budget Models with12x, 8x 6x or 4x SFP ports HSR switches model Extensive diagnostics functionality
LANactive Industry More about the solution for mission critical applications: www.nexans.com/LANsystems
Application Nexans iGigaSwitch 16xx E+ family presents full gigabit industry grade managed DIN-rail mounted switches designed to ensure extremely high reliability and long lifespan in harsh environments of different mission critical applications. Those switches are targeted to provide highest network availability, security and to make network maintenance much easier. Nexans iGigaSwitch 16xx E+ family provides high flexibility in network design – they have up to 16 ports: fibre-optic or copper in different com-
binations, including the variant with 12x SFP and 4x RJ45 ports. The switches allows to adapt the interfaces to the application by using the corresponding pluggable modules (Fast Ethernet or Gigabit SFP). I/O Interfaces (optional) I/O interfaces allow a fast, simple and low-cost integration of additional non-Ethernet devices directly in the field. The switches are offering extensive management functionalities with interactions, sending of messages as well as the activation of alarms.
Power over Ethernet+ (optional) Up to 12 connected users can be supplied with Power over Ethernet. In accordance with the latest IEEE 802.3at (PoE+) standard, up to 25.5 watts of power are available for each connected device (360W budget). IEC 61850 compliance Nexans iGigaSwitch family enable an intelligent communication environment for Smart Grids supporting the IEC 61850 standard (parts 6, 7-1, 7-2, 7-3, 7-4, 8-1, 9-1 and 9-2 Communication networks and systems for power utility automation).
Features General • 16 Port Switch • up to 12x Vario-SFP ports • 10/100/1000 Mbps • Support of Jumboframes • -40°C ... +85°C (Operation) • HSR model is available • IEC 61850 standard compliance (parts 6, 7-1, 7-2, 7-3, 7-4, 8-1, 9-1 and 9-2)
I/O Interfaces (optional) • 4x potential-free function inputs and 2x programmable alarm contacts
Memory card (optional) • Memory card with MAC-Address • System Configuration and fimware backup on Memory Card and boot up with Memory Card MAC address and Configuration Redundant Power Supply • Two redundant Wide Range Power Supply Inputs (18 VDC ...72 VDC)
Energy Management • Low Power Design (typ. 15 Watts)
Twisted Pair User Interfaces • up to 12x RJ45 user interfaces (10/100/1000 Mbit/s) • MDI/MDI-X Auto-Crossover and Auto-Polarity
Mechanic • Ruggedized design without vents and holes • Compact design (95mm x 184mm x 125mm)
www.nexans.com/LANsystems
•
Power over Ethernet+ (optional) • up to 12x Power over Ethernet (PSE+) according to IEEE 802.3at Management • WEB/SNMP/SSH/V.24 Management • Hardened management, corruption impossible • LLDP and CDP • Compatibility to “Cisco Identity Services Engine ISE“ • Extensive security functions SCP, SSHv2, HTTPS, RADIUS, SNMPv3, IEEE802.1X etc. • Integrated in ARP Guard Secure Management • Configuration via NexMan (administration tool) • IPv6 according to IPv6 Forum phase 2 core specification
[email protected]
Technical data iGigaSwitch 16xx E+ family
Version Order numbers
iGigaSwitch 1604 E+ SFP-4VI PRO3
iGigaSwitch 1606 HSR SFP-6VI PRO4
iGigaSwitch 1608 E+ SFP-8VI PRO3
iGigaSwitch 160C E+ SFP-12VI PRO3
88306400
88306406
88306408
88306412
88301602
Memory card with MAC address
88300692
Memory card with MAC address and MRP Multi licence
88300694
iOption PoE Type at 4-30
88301602
88301602
88301602
iOption PoE Type at 8-30
88301604
88301604
88301604
-
iOption PoE Type at 12-30
88301606
-
-
-
I/O module digital 4xIn 2xOut
88301600
RJ45 serial cable for iGigaSwitch
88646169
LAN Interfaces Twisted Pair interfaces (RJ45) SFP interfaces
12x 10/100/1000 Mbps
10x 10/100/1000 Mbps
8x 10/100/1000 Mbps
4x 10/100/1000 Mbps
4x 100/1000 Mbps
4x 100/1000 Mbps
8x 100/1000 Mbps
12x 100/1000 Mbps
-
2x 100/1000 Mbps
-
-
SFP interfaces HSR
in connection with PoE options
Power over Ethernet (optional) Number of RJ45 ports with PoE+ Max. PoE power output
max. 12x PoE+
-
max. 8x PoE+
max. 4x PoE+
360 Watt
-
240 Watt
120 Watt
Diagnostic functions (Interfaces) Digital Diagnostic Monitoring interface
Yes
Twisted Pair cable diagnostic
Pending
General Housing
Anodised / varnished aluminium case
Color Mounting
Black 35mm DIN-Rail Mounting accoring to EN 60715, (EN50022), different positions of DIN-rail clip, optional: wall mounting
Dimensions [WxHxD]
95 mm x 184 mm x 125 mm
IP degree of protection
IP 30 (EN 60529)
Ambient temperature
Operation: -40 ... +85 °C, Storage: -40 ... +85 °C
Relative humidity
20 - 90 % (non-condensing)
Weight MTBF
1800g >500.000 h
>500.000 h
>500.000 h
>500.000 h
BTU Power suppy Input voltage for switch
min. 18 / tipical 24 / max. 72 VDC
Input voltage for PoE+
min. 46 / tipical 54 / max. 57 VDC
Power consumption without PoE+
min. 13 / tipical 15 / max. 28 W
Interface connector for power source
2x 3-pin terminal block, screw-on type
Separate PoE input
Yes
Interface connector for PoE Source
3-pin terminal block, screw-on type
I/O Adapter - Alarm contacts - Function inputs (optional) I/O interface connector (optional)
16-pin teminal block (screw-on type)
Number of outputs
2x independent outputs (Changer function)
Current/Voltage of Output contacts
2A / 30V DC
Auxiliary voltage sorurce
24V DC /max. 42mA / For support of digital contacts
Number of digital inputs
4x
Input Voltage of input contacts
12 - 60V DC
Dry contacts support
Yes / Via auxiliary voltage provided by the switch
Functional parameters Firmware Type Data throughput
PRO3
PRO4
PRO3
> 1.488.000 Pakete/Sek. per Port (FDX, bidirectional)
Switching method
Store and forward, self-lerning
Max. Framesize
9.600 bytes (Support of Jumboframes)
Paket Buffer
512 kByte
Max Frame Length 10/100/1000 Mbit/s
9000
Max MTU Length 10/100/1000 Mbit/s
9582
Backplane capacity
50 GBit/sec 100Mbit/s 64Byte: 9µs / 3,9µs 100Mbit/s 1518Byte: 125µs / 4µs 1Git/s 64Byte: 2,7µs / 2,2µs 1Gbit/s 1518Byte: 15µs / 2,5µs
Latency time (FIFO/LIF0)
www.nexans.com/LANsystems
•
[email protected]
PRO3
Technical data iGigaSwitch 16xx E+ family
Version
iGigaSwitch 1604 E+ SFP-4VI PRO3
iGigaSwitch 1606 HSR SFP-6VI PRO4
iGigaSwitch 1608 E+ SFP-8VI PRO3
iGigaSwitch 160C E+ SFP-12VI PRO3
On-Board High-Performance Management
Management Memory Firmware update
Update in separate FLASH area, Corruption impossible
FLASH Configuration
Dual Configuration, Corruption impossible
Secure management protocols
SCP, SSH, HTTPS, SNMPv3
Passwort Strength Checker
Yes
Configuration reset button
Yes (Configuration button deactivatable) SD memory card with fixed MAC-Address for redundant storage of the complete switch configuration and firmware (optional)
Memory Card Console Interface
Yes (Cisco like)
Standards Electrical safety (IT equipment)
EN 60950
Electrical conditions (EMC)
EN 55022 IEC 61850-6, 7-1, 7-2, 7-3, 7-4, 8-1, 9-1 and 9-2 IEC 61850 Certificate Level A IEC 61850 SERVER functionality - MMS and GOOSE KEMA certified
Communication networks and systems for power utility automation General environmental requirements for hardware design
IEC 61850-3
Environmental Standards for Networking Devices Installed in Power Utility Substations
IEEE 1613
Immunity for industrial environments
IEC 61000-6-2
Adjustable speed electrical power drive systems Redundancy protocols
Others (abstract)
IEC 61800-3 STP, RSTP, MSTP (pending), MRP
HSR STP, RSTP, MSTP (pending), MRP
STP, RSTP, MSTP (pending), MRP
STP, RSTP, MSTP (pending), MRP
CE, IEEE 802.3x (Flow Control), IEEE 802.1AB (LLDP), IEEE 802.1D (MAC Bridges), IEEE 802.1D (Rapid Spanning Tree Protocol), IEEE 802.1D (Class of Service), IEEE 802.1X (Port-Based Network Access Control) ANSI/TIA-1057 (Link Layer Discovery Protocol for Media Endpoint Devices), ISO/IEC 15802-3 (Media Access Control Bridges), IEC 62439-2 (Media Redundancy Protocol-MRP)
184mm
193mm
Dimensions
125mm 139mm
95mm
www.nexans.com/LANsystems
•
[email protected]
Management Features (Extract) iGigaSwitch 16xx E+ family Access Control / Authentication Management 5 admin account with Read/Write access for HTTP/HTTPS, Telnet/SSH/V.24 console and NexMan Access Policy Mode with disabling function for unsecure protocols, activation of SSHv2, HTTPS, SNMPv3 and „Password Checker“ Gratuitous ARP function guarantees that the switch can be reached after change of IP address Securely encrypted transfer of configuration und firmware via SCP- Secure Copy IPv6 according to IPv6 Forum phase 2 core specification WEB / HTTP / HTTPS Access WEB interface (no proxy server required) TCP port number can be set for WEB access Telnet / SSH and V.24 Console Telnet console (no proxy server required) and Cisco-like command line interface SSH/Telnet or V.24 console can be disabled respectively SSH/Telnet and V.24 console authentication via RADIUS server Secure 256-bit encrypted SSH / SSL transfer and use of 1024-bit RSA keys SNMP Access, SNMP Traps and Syslog Messages Configuration of switch possible via “SNMP Set Request“ MIB-II (RFC1213) system, interface, at, ip ETHERLIKE MIB (RFC2665) dot3StatsTable IF-MIB (RFC2863) ifXTable BRIDGE-MIB (RFC4188) dot1dBase, dot1dStp, dot1dTp RSTP-MIB (RFC4318) RMON-MIB (RFC2819) statistics Eight IP addresses can be set as event receivers for SNMP traps, Alarm and Syslog messages Up to 27 different event types can be enabled per receiver Portsecurity Loop/broadcast limiter for protection against accidental or malicious packet storms Active loop protection with automatic disablement of short-circuited ports Manual definition of three authorized MAC addresses per port Automatic learning of up to three authorized MAC addresses per port Port switches off, when an unauthorized MAC address is detected SNMP trap/syslog message for newly detected or for unauthorized MAC address Transparent transmission of IEEE802.1x packets can be enabled/disabled RADIUS authentication of up to three MAC addresses per port Port authentication according to IEEE802.1x in connection with the RADIUS server Unauthenticated ports are switched into a freely selectable Unsecure-Default-VLAN VLAN Support / Trunking VLAN table selectable with up to 256 VLAN IDs, static or dynamic configurable Default-VLAN ID can be set for each port Default-VLAN can be disabled for trunking ports Trunking with tagging in accordance with IEEE802.1q can be enabled/disabled for each port Prioritization of the VLAN tags selectable according to IEEE802.1p Prioritization Prioritization selectable per each port according to IEEE802.1p / IPv4 and IPv6 Four output queues selectable for prioritization weighting per port 4 Prioritization scheme {strict queuing}, {8,4,2,1 weighted fair queuing} , {3 strict/2,1,0 weighted}, {2,3 strict/1,0 weighted} Discovery Protocols LLDP (Link Layer Discovery Protocol) CDP (Cisco Discovery Protocol) Switch Information / Configuration Configuration of IP parameters via DHCP and manual configuration of IP parameters possible Configuration of IP parameters possible without pressing configuration switches (NexCon) Loading of a Switch Configuration or firmware via Telnet/SSH/V.24/DHCP/BOOTP console possible Output of the running configuration in Telnet as CLI script and optional saving on an external TFTP server. Firmware and Configuration Management via Nexans Switch Manager Prevention of corruption through firmware update in separate FLASH segment Avoid corruption of configuration changes with dual configuration management NexMan authentication via RADIUS server Download / upload of the configuration and archiving in a database on the PC Upload of a new configuration into the switch is made On-The-Fly (no reboot required) Archiving of the configuration in an offline database (using NexMan) Securely encrypted configuration via SNMPv3 Link Aggregation LACP Redundancy RSTP - Rapid Spanning Tree Protocol MSTP - Multiple Spanning Tree Protocol Power over Ethernet Detection, monitoring and display of PoE related values, voltage and consumption 5 different modes: Power Setup, Off / On / Auto - 802.3af / Auto 802.3af High-Power /Auto 802.3at High-Power Environment Diagnose/Monitoring/Mirroring Display of internal operating voltages and housing temperature SNMP trap/alarm and syslog messages, if temperature is exceeded Logbook for permanent internal saving of syslog messages 35 counters for packets, bytes, Unicasts, Broadcasts, etc. per port Port monitor for individual ports Switch can be set to VLAN mirroring Display of SFP Information: Vendorname, Part Number, Serial Number, Datecode, etc. Display of SFP Diagnostics: TX and RX power in uW and dBm, temperature, voltage, bias current Configurable Alarm limits for TX- and RX-Power as well as for Laser-Bias-Current SNMP-Trap/Syslog-message activation for preset alarm limits Other Network Protocols IGMP Snooping (Internet Group Management Protocol) can be activated globally, IGMP protocol versions 1 or 2 can be selected SNTP (Simple Network Time Protocol) can be activated globally
www.nexans.com/LANsystems
•
[email protected]
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Pending • Pending • • • • • • • • • • • • • •
Accessories iPowerSupplies – Nexans industrial power supplies • • • •
Easy installation on the DIN-rail or wall Maximum energy efficiency thanks to low idling losses Models with startup temperature > -40°C Overload and short circuit-/no-load protection
NOMINAL OUTPUT VOLTAGE
OUTPUT VOLTAGE
POWER OUTPUT
AC INPUT VOLTAGE RANGE
Nexans iPowerSupply S 115-230VAC/24VDC 30W
24V DC
24
30W
85...264V AC
88645963
Nexans iPowerSupply S 110-230VAC/24VDC 100W
24V DC
22.5-29.5
100W
85...264V AC
88646182
Nexans iPowerSupply S 115-230VAC/48VDC 60W
48V DC
48
60W
85...264V AC
88645960
Nexans iPowerSupply S 115-230VAC/48VDC 100W
48V DC
30…56
100W
85...264V AC
88646250
Nexans iPowerSupply S 115-230VAC/48VDC 240W
48V DC
30…56
240W
85...264V AC
88646072
Nexans iPowerSupply S 115-230VAC/48VDC 500W
48V DC
30…56
500W
85...264V AC
CODE
NAME
88646181
DC INPUT VOLTAGE RANGE
95...250V DC
95...250V DC
SFP modules • • • • • •
Gigabit and Fast Ethernet SFP modules Dual and single fibre variants Digital Diagnostic Monitoring Interface to readout specific parameters (e.g. temperature, optical input/output power) Wide operation temperature range: from -40°C up to +85°C Copper and E1 SFP modules are available Other modules, including vendors compatible versions are available upon request
FIBRE TYPE
WAVELENGTH TYP., NM (TX/RX)
TYP. LINK RANGE M
OPTICAL BUDGET MIN, DB
MM, Dual fibre
1310/1310
2.000
12
Nexans SFP 100 Transceiver SM(LC)E L10
SM, Dual fibre
1310/1310
10.000
16
Nexans SFP 1000 Transceiver GI(LC)E
MM, Dual fibre
850/850
550
9
88646016
Nexans SFP 1000 Transceiver SM(LC)E L10
SM, Dual fibre
1310/1310
10.000
12
88646017
Nexans SFP 1000 Transceiver SM(LC)E L40
SM, Dual fibre
1310/1310
40.000
19
88646018
Nexans SFP 1000 Transceiver SM(LC)E L80
SM, Dual fibre
1550/1550
80.000
24
88646019
Nexans SFP 1000 Transceiver SM(LC)E L120
SM, Dual fibre
1550/1550
120.000
29
88646073
Nexans SFP 1000 Transceiver SF3(LC)E L10
SM, Single fibre
1310/1550
10.000
12
88646075
Nexans SFP 1000 Transceiver SF5(LC)E L10
SM, Single fibre
1550/1310
10.000
12
88646133
Nexans SFP 1000 Transceiver SF3(LC)E L40
SM, Single fibre
1310/1550
40.000
19
88646135
Nexans SFP 1000 Transceiver SF5(LC)E L40
SM, Single fibre
1550/1310
40.000
19
88646226
Nexans TP SFP Transceiver 10/100/1000 Base-T
RJ45
N.A.
100
N.A.
88646279
Nexans E1/T1 SFP Module
RJ45
N.A.
1500
N.A.
CODE
NAME
88646010
Nexans SFP 100 Transceiver GI(LC)E
88646011 88646015
www.nexans.com/LANsystems
•
[email protected]
Accessories NEXMAN device manager • • • • • • • •
CODE
Easy, intuitive and comfortable solution for centralised network configuration and management Auto discovery functionality Live device monitoring Master configuration functionality Integration into higher level management systems Client-Server capability Alarm management and logging Simultaneous firmware update for hundred of devices
NAME
-
NEXMAN Device Manager, Evaluation Version
88301908
NEXMAN Device Manager, Single Licence
88301909
NEXMAN Device Manager, Company Licence
Memory cards for industry switches • • • •
Redundant encrypted storage (AES256) for industrial switches Switches stores its complete and most actual configuration and firmware automatically Using memory cards with MAC-address makes network maintenance processes much easier Two variants of memory cards: with MAC-address or with MAC-address and MRP multi license
CODE
NAME
88300692
Nexans SD Memory Card for iGigaSwitch with MAC-Address
88300694
Nexans SD Memory Card for iGigaSwitch with MAC address and MRP-Multi licence
• • •
CODE
NAME
88646169
Nexans RJ45 console cable for iGigaSwitch family
The V.24 console port on Nexans switches allows to configure the switch on site and/or to retrieve its status without an Ethernet network connection Configuration via the V.24 console port provides the same functionality as configuration via Telnet or SSH USB to Serial converter “Digitus DA-70156 USB to Serial Converter USB 2.0” or similar is recommended for PC‘s without DB-9 serial connector
Nexans Deutschland GmbH • Advanced Networking Solutions Bonnenbroicher Str. 2-14 • 41238 Moenchengladbach • Tel +49 (0) 2166 27-2220 • Fax +49 (0) 2166 27-2499 E-Mail:
[email protected] • www.nexans.com/LANsystems
Copyright © Nexans 2017 - Subject to change without prior notice - kd-01168e05
Console configuration cables