Preview only show first 10 pages with watermark. For full document please download

Iguassu Ice 500 Technical Manual

   EMBED


Share

Transcript

Technical & Repair Guide for ChungHo IGUASSU ICE 500 IGUASSU ICE 500 Technical Manual Call 888.758.1234 for further technical support. Table of Contents 1. Designation of Components page 3 2. Product Features page 4-6 3. Exploded Diagram & Parts List 3-1. Overall Exploded Diagram 3-2. Ice Making Department 3-3. Detailed Exploded Diagram (1) 3-4. Detailed Exploded Diagram (2) 3-5. Detailed Exploded Diagram (3) 3-6. Parts List page 7-13 4. System Diagram 4-1. Water Purification Procedure 4-2. Ice Making Procedure page 14 5. Distribution Line Diagram page 15 6. Product Specification page 16 7. Installation Precautions page 17 8. Relocation/Installation Precautions page 18 9. Installation page 19 10. Usage 10-1. Display 10-2. Water Dispensing & Buttons 10-3. Operational Beep 10-4. Select/Deselect Function 10-5. Ice and Water Dispensing 10-6. Understanding the Ice Making Process and Operation page 20-24 11. PCB Diagrams page 25-26 2 11-1. Main PCB 11-2. Power PCB 12. Examination/Repair Procedure page 27-50 13. Flow Charts page 51-57 1 Designation of Components 1-1 FRONT USB Port Ice Full LED Water Full LED Hot Water/Ice Lock Button Drain Switch Continuous Dispensing Mode Button Hot Water Selecting Button Ice Dispensing Button Water Dispensing Nozzle Water Dispensing Push Button Ice Dispensing Hole Power Cord Drain Outlet Waste Water Outlet Water Source Inlet Top Cover Ambient Water Tank Front Upper Panel Ice Making Unit Cold Water Tank Ice Storage Drip Tray Hot Water Tank Drainage Valve Wire Condenser Filters Front Lower Panel Compressor Booster Pump Designation of Components Cold Water Selecting Button 3 Product Features 2 The IGUASSU ICE 500 is designed for both convenience and practicality, as it utilizes a compact ice making system, designed to obtain cold water for the production of ice. The system features an ice making mechanism featuring an ice tray, which utilizes the freezing point method as well as reverse osmosis water purification. (Patent application: No.2005-99663, 2005-365293, 200510127096.9, 11/342,117) 24 Hour Natural Water Circulation System (N.W.P.W.) natural weight of water pressure in order to supply clean and fresh water at all times. (Patent: No.105585) Pure Ice Production Utilizing the Freezing Point Method The Freezing Point Method produces only the purest ice by supplying purified water to the ice making mechanism. The freezing point principle states that the purest water freezes at 32°F while unpurified water will freeze at a temperature below that. Energy Saving Function The IGUASSU ICE 500 is an energy-efficient product. It delivers purified water to the ice making system in order to make pure ice while simultaneously sending cooled water to the cold water tank. It allows the system to maintain a constant cold water temperature, thus inherently preventing water waste and helping to conserve energy. Automatic Ice Dispenser Upon pressing the ice dispenser touch sensor button, the system then slowly rotates the ice storage plate via an integrated motor in order to automatically replenish the ice supply within the storage housing. Touch Sensor Application Breaking away from traditional button applications, IGUASSU ICE 500 has a built-in touch sensor and ice. 4 Infrared Water Level Detection Sensor The Infrared Capacitive Water Level Sensor is applied in the SUPER IGUASSU ICE 900. It provides more improved detection accuracy than traditional mechanical detection sensors, thus allowing stable water level detection. The signal is connected to a controller in order to automatically adjust purified water levels. (Patent: No.426182) Safety Function (Ice Dispensing & Hot Water Locking Function) Setting the safety function using the LOCK/ICE touch sensor button prevents ice cubes and hot water from being dispensed from the unit. It helps to prevent again burns and other unwanted injuries to children, the elderly and any other vulnerable user. Continuous Water Dispensing Mode* The IGUASSU ICE 500 has a continuous water dispensing function, which allows users to dispense cold/ambient water continuously. The system maximizes user convenience since a set volume of water, can be dispensed at the touch of a button. *Not available for hot water. Automated Operation via Sensor and Micom This system internally provides temperature control for the ice making process/cold water process by way of an ice detection sensor, so that ice making, ice removal, and cold water operation, via Micom, may be automatically controlled in order to maintain an optimum operation. Product Features 4 Functions (Ambient Water, Cold Water, Hot Water, Ice) in 1 Product! Separate Water Delivery from a Single Spout Ambient, cold, and hot water are dispensed from a single spout, but independent water hoses are applied so that the different temperatures is not mixed, thus improving overall satisfaction in preferred temperature from the first drink. 5 Noise Prevention utilizing a shock mitigation structure at ice storage house, etc. System Display Functions and Safety Reinforcement The safety features of the product have been enhanced in order to prevent various problems. The when an abnormality in the system is detected. Automatic Water Dispensing The system is convenient to the user because it enables ambient water, cold water, and hot water to be taken at the press of a button. Beep Function It provides customers with a convenient reminder that a system setting has been changed via beeping (ding~, dingdong~, etc.). ProductFeatures Wire Condenser (Natural Convection) Using natural convection, the system wire condensers are rated to reduce noise and thus provide further convenience for the user. 6 Adoption of New Coolant - The IGUASSU ICE 500 has adopted an environmentally friendly cooling system using the R-134a coolant. Default Function Cold water, which is most frequently used, is the system’s default setting. Also, the system is designed to automatically convert to cold water mode when in queue. Exploded Diagram & Parts List 이과수 얼음 냉온정수기 500 �� ����� �� ����� �� �� �� �� �� �� ��� ��� 3 3-1 overall diagram Drainage Switch A/C Power PCB Hot Water Dispensing Solenoid Valve Cold Water Dispensing Solenoid Valve -6- 청호나이스 환경기술연구소 Exploded Diagram TR 7 이과수 얼음 냉온정수기 500 �� ����� �� ����� �-�� �-�� �� �� ���� ���� �� �� ��� ��� zzzz 3-2 ICE MAKING DEPARTMENT Sub Tank Ice Full Sensor (RX) OLC Exploded Diagrram Ice Full Sensor (TX) 8 Inlet Solenoid Valve Synchronous Motor (Camshaft) Dischsrge Door Motor Dischsrg Motor Cold Water Temperature Sensor Cold Water Level Sensor Circulation Pump Cold Water Dispensing Valve Hot Water Dispensing Valve Ambient Water Dispensing Valve -7- 청호나이스 환경기술연구소 이과수 얼음 냉온정수기 500 �� �� ����� ����� �-�� �-�� �� �� �� �� ��� ��� ��� ��� 3-3 detailed exploded diagram (1) 청호나이스 환경기술연구소 Exploded Diagram -8- 9 이과수 얼음 냉온정수기 500 �� ����� �� ����� �-�� �-�� �� �� �� �� ��� ��� ��� ��� Exploded Diagrram 3-4 detailed exploded diagram (2) 10 -9- 청호나이스 환경기술연구소 이과수 얼음 냉온정수기 500 �� �� ����� ����� �-1� �-1� �� �� �� �� ��� ��� ��� ��� 3-5 detailed exploded diagram (3) Exploded Diagram - 10 - 청호나이스 환경기술연구소 11 이과수 얼음 냉온정수기 500 �� �� ����� ����� �-�� �-�� ����� ����� ���� ���� 1�� 1�� 3-6 Parts list Ice making inlet PIPE T - Cold water dispensing Drip Tray Grill-Drip Tray Dispensing Button #2 Dispensing Button Cover #2 FAUCET DECO- Separate oval Manifold (oval) Cold/Hot LED Window - oval LED Window - square Exploded Diagrram LED Window - Cold/Hot/Ambi 12 EPS-Circulation PUMP Ambient water tank COVER - Ambient tank Ice making Unit Noise reducing Basket Ice making PUMP HEAD Ice dispensing DOOR Cleaning Valve Rotating Drip Tray RUBBER-Dispensing btn. Rotating Drip Tray BUSHING (L) Rotating Drip Tray BUSHING (R) Pipe-Sub tank Connect Ambi Inlet SOV BKT Pipe-Hot water tube Connect Ambi Dispensing SOV BKT Cold/Hot SOV BKT PCB - Function Select EVA.fixing BRAkET PCB - Dispensing Select PCB - Ice Dispensing Drip Tray Motor S/W PANEL Drip Tray Motor Coupling Ice discharge Guide FRONT Ice discharge Guide BACK Ice ejection Heater - 11 - 청호나이스 환경기술연구소 이과수 얼음 냉온정수기 500 �� �� ����� ����� �-2� �-2� ����� ����� ���� ���� 2�2 2�2 Drain Switch Level Sensor-Ambi (OLC-S3) Level Sensor - Cold MOTOR- Ice Discharge TUBE - Cold water Dispensing MOTOR- Rotating Drip Tray Circulation Pump Booster Pump (water) Discharging DOOR - MOTOR SOL V/V - Inlet SOL V/V - Ambi Dispensing SOL V/V - Cold Inlet SOL V/V - Cold Discharging SOL V/V - Hot Discharging ICE FULL Sensor-receiving ICE FULL Sensor-transmitting Cold Water Temp. Sensor EVA.PIPE fixed BKT (bottom) Exploded Diagram EPS-Cold temp. Sensor Ice Storage drain insulate EPS TUBE - Ambi Dispensing Ice Storage drain TUBE TUBE - Hot water Dispensing - 12 - 청호나이스 환경기술연구소 13 4 System Diagram 10. Flow Diagram and Power Consumption 이과수 얼음 냉온정수기 500 �� 10-1. Flow Diagram �� ��� ��� 4-1 WATER�-1� PURIFICATION PROCEDURE �� ������ ��� �-1� �� ������ ��� 냉수 배수 �-�� �-�� ������ ������ ������ ������ ��� ��� 4-2 ICE MAKING PROCEDURE 10-2. Power Consumption Evaporator EVAPORATOR(증 발 기 ) 회 전Tray 물받이 Drip Division 냉Water 수 Cold Tank 탱크 HOT : ON LOCK :OFF Power Consumption/ WireCONDENSER Condenser WIRE Ice Grill Ice GrillCondition Operation month(±10%) Ice음 Storage 얼 저장고 Hot/Ice making/Cold 48.5 kWh/month Ice making/Cold 24.5 kWh/month Liquid 액 분리기 Seperator Capillary 모Tube 세관 HOT : OFF LOCK :OFF Hot Gas Sol. 냉매주입구 드라 이어 Drier V/Vabove information is measured in terms of real-using environmental condition.(Standard : A family of four) ※Reference. 1) The 열 교Exchanger 환기 Heat -Non-operation Condition: The conditions of ice making, cold and hot are under preparation. -Real-using environmental condition(1 person 3 meals per day) : Iced water Cold water(150cc) + Ice cube 8pcs(100g) 3 times, Coffee & Tea Hot water(150cc) 2 times Compressor COMPRESSOR 2) It may happen small deviation(±10%) ※If you want to cut down power consumption, as the chart above, you had better turn off Hot water function. The halt of cold and ice making functions has not noticeable results compared to hot water function. Therefore, this product 청호나이스 환경기술연구소 - 13 doesn't have option to cancel Cold and Ice making functions. 14 5 Distribution Line Diagram 5. 5. 배선도 배선도 이과수 얼음 냉온정수기 500 USB PCB 5V Function Selection 기능선택 PCB PCB 정수 수위검출기 Ambi water level Sensor NC COM 잠금 Lock 0.5L 연속 Const. 1.0L 냉수 정수 온수 Dispensing 취수 선택PCB PCB Selection CN1 GND DC5V 주위온도센서 Environ. Temp. Sensor CCW-Ice making CCW-제빙 CCW-Ice ejection CW-탈빙 Environ. Temp 주위온도 KEY1 COM2 KEY2 COM3 COM1 COM4 I/O 0 I/O 1 I/O 2 CDS IN DC 12V GND 5V GND CN2 백색 White 디스플레이 Display CN4 백색 USB White CN9 적색Drip 물받이스위치 Red Tray Switch CN7 GND 1 흑색 Black 만빙센서 ICE Full Sensor Signal 2 Main PCB 백색 White NO NC 청색 수위검출기 Sensor Blue CN5 level CN8 GND Blue 청색 5V 만빙센서 ICE Full Sensor 수신 Receiving 1 2 냉수센서 Cold Sensor POWER PCB Signal 3 CN10 청색 Blue CN17 백색 White 누름 Button 버튼 Press CN6 WHT 토출 DOOR CN12 Discharging Door 1 5V Signal 2 제빙센서 Ice Making Sensor 냉수수위검출기 Cold water level Sensor 12V BB출력 Output AA출력 Output B-B-출력 Output A-A-출력 Output GND Signal 5V Signal GND DC 12V NO COM Hot 온수 Power 정수펌프 Booter Pump 온수가동점 Hot re-op. point Re-operation 재가동점 point 만수Point Water Full point 1 5V 2 GND CN16 DC12V 1 백색 Signal 2 White GND 3 NC COM 송신 Transmitting 원수 밸브 OUT CN3 Clear 얼음토출모터 Motor-Ice Ejection AC21V IN AC21V IN AC220V 동기모터 Sync Motor CCW CW AC220V 동기모터 Sync Motor Ice제빙 Making CN4 Power PCB COM Ice탈빙 ejection 백색 White Drip Tray Motor 물받이 모터 백색 White CN1 Clear CN5 FUSE AC250V 8A COM AC220V 60Hz 전원코드 Power Cord CN6 Clear Ice탈빙히터 ejection Heater CN6 Clear DC24V 급수V/V 밸브 Inlet 냉수water 밸브V/V Cold 온수 밸브 Hot water V/V 정수water 밸브V/V Ambi Ice ejecting Controller 탈빙제어소자 Discharge Motor 토출모터 Motor-Ice Making 모터 제빙방향 모터 탈빙방향 Motor-Ice Ejection 탈빙릴레이 Ice ejection Relay 콤프레셔 Compressor 온수히터 Hot water Heater 순환펌프 Circulation Pump 정수 취수 밸브 Ambi Dispensing V/V 온수 취수 밸브 Hot Dispensing V/V 냉수 취수 밸브 Cold Dispensing V/V 급수 밸브 Inlet Valve 정수 Pump/ Pump/ Ambi Sol.Sol DC24V DC 12V GND 정수펌프 Booter Pump IN AC21V 1.9A TRANSFORMER(T/R) pump Main PCB 13 14 15 Power GND 온수가동점 Hot re-op. point 재가동점 point Re-operation 만수Point Water Full point COM 배수S/W Drain Switch NC NO CN11 흑색 배수스위치 Black Drain Switch 급수Valve 밸브 1 Inlet 2 Cold 냉수Dispensing 취수 밸브 V/V 온수 취수 밸브 3 Hot Dispensing V/V 4 Ambi 정수Dispensing 취수 밸브 V/V 5 Circulation 순환펌프 Pump 6 Hot 온수히터 water Heater 콤프레셔 7 Compressor 탈빙릴레이 8 Ice ejection Relay 9 Motor-Ice 모터 탈빙방향 Ejection 모터 제빙방향 10 Motor-Ice Making Discharge Motor 11 토출모터 12 탈빙제어소자 Ice ejecting Controller 물받이 S/W S/W Drip Tray위치 Position Ice얼음토출 dispensing PCB PCB 만빙 Ice Full Water 만수 Full 정수 Ambi 밸브 V/V Inlet 급수 밸브 V/V 냉수 Cold 밸브 V/V 온수 Cold 밸브 V/V 취수 SolSol. Dispensing AC 220 V NC AC 220 V Compressor 콤프레셔 탈빙용 Heater Ice ejection Heater AC220V AC220V AC220V Comp 탈빙 HeaterHeater Ice ejection 온수 히터Heater Hot water Ice제빙펌프 making Pump Hot water Heater 온수 Heater AC220V 400W AC220V 400W 수동 바이메탈 Manual Bimetal 자동 Auto바이메탈 Bimetal AC220V AC220V 순환 PUMP Circulation Pump 15 Product Specification 9. Product Specification Product name Model name IGUASSU ICE 500 CHP-5110S Rated voltage AC 110V/60Hz, 220V/50Hz, 240V/50Hz, and 220V/60Hz External dimension 295W X 384D X 1170H(mm) Consumed power Storage house Rated consumed power 500W(hot water+ ice making) Hot water 500W Cold water / Ice making 105W Ambient water 1.58G(6.0ℓ) Hot water/Cold water .39G/.55G(1.5ℓ/2.1ℓ) Ice 2.6lbs.(1.2kg) Monthly consumed power quantity Weather class Surrounding temperature Ice making Required time capability (This can Daily ice making quantity differ (60Hz/50Hz) depending on Daily maximum ice making surounding quantity tempera(60Hz/50Hz) ture.) Ice size 16 6 48.5kWh/month N class(90℉±1℉(32℃±1℃)) 86℉(30℃) 68℉(20℃) 13minutes±1minute/ one time ice making 17minutes±1minute/ one time ice making 17 lbs(8kg)/day(60Hz) 13 lbs(6kg)/day(60Hz) 17 lbs(8kg)/day (60Hz) (when surrounding temperature is 68℉(20℃) 13g±1gX12ea/one time ice making (1ea cold water tank submerging) Heat radiation type WIRE CONDENSER TYPE (natural convection) Cold water temperature regulation THERMISTOR Hot water temperature regulation Bimetal(automatic return) Overheating prevention system Bimetal(manual return) Safety system Overheating prevention system, water level detecting system Cold water tank water level adjust- Capacitance sensor ment Refrigerant/Refrigerant weight R-134a(85g±1g) Product weight 78.2 lbs.(35.5kg) Power cord 2.5m IP class IPX1 19 Installation Precautions 7 When installing the product, do not install it at the following places. - Near a fire. - Near flammable materials. - Wet areas - Areas with direct exposure to rain and snow. - Areas with direct exposure to sunlight. - Near chemicals (volatile materials, organic solvents, etc.). - Areas with temperatures below 32°F. *When the product is installed in a dark area, the hot water system may not operate if the power saving (ECONO) mode is set, even during the daytime. Install the unit in a bright area. Use the following water quality range. - Water Pressure : 7~120 psi (0.5~8.4 kgf/cm2) - Water Temperature : 39 ~ 100°F (4~38°C) - pH : 5 ~ 10 - Hardness : 300 ppm or less - Evaporation remains : 500 ppm or less - Water Quality : Biologically safe water quality If you do not use water quality within the above range without prior discussion of our company, the product can be excluded from the stated warranty period. When transporting the product, do not tilt it over 45°. Severe tilting can be the cause of reduced performance. Do not connect hot water(over 100°F) to this product. Leave approximately 8 inches, between the wall, sides and rear surfaces of the product for proper ventilation to ensure the safe operation of the product. When connecting the tubing hose, be sure that it is not bent or pressed down by heavy objects, etc. Adjust the hose so that the water discharged from the drainage hose does not splash onto the product’s surrounding area. Brine water, or the water coming out through drainage lines, can easily be applied towards other water related needs, such as in bathroom cleaning, house cleaning laundering, washing, etc. in order to prevent waste of water. However, never use the brine water as drinking water or for cooking of food. Raising the brine water and drain water over 1 ft. above the installation surface, or connecting them over 6 ft. away from the water purifier can hinder a smooth drainage process. In order to install the product in at a location where the brine water and drained water line are located at a distance of over 6 ft. from each, the user must install a separate drainage pump. the water is derived from the same installation source, prepare an independent drain line for 8 each product. 17 (2) Hot Water Dispense Mode If HOT(hot water selection) touch sensor button is selected and water dispensing button is pressed, hot water comes out. ※If HOT LOCK(hot water lock) is set, then hot water does not co out even though the water dispensing button is pressed. ※If HOT LOCK(hot water lock) function is released, the water in hot water tank can be taken by selecting HOT(hot water selectio touch sensor button and pressing the water dispensing button. the me the n) Relocation/Installation Precautions Note : The flushed water from water dispensing hole is around 127℉(95℃ careful against a burn from hot water. Please use container as like Cup. (3) Cold Water Dispense Mode If COLD(cold water selection) touch sensor button is selected a dispensing button is pressed, cold water comes out. ) and be nd water 8 (4) Ambient Water Dispense Mode If AMBI(ambient water selection) touch sensor button is selecte d and water dispensing button is pressed, ambient water comes out. In a case ※If where a product to be transported, sure that the system is completely hot water or ambientneeds water is selected and it is not used fplease make or a given time drained ofperiod, watertheand icewillbefore moving product. system automatically switch the into cold water di spense mode. (Default function) (If the product without drainage ※Thereisismoved not a separate settingthe andcomplete release method for the useprocess asofdescribed ambient below, it may cause serious damage to the product.) water/cold water/ice making operation. They operate automatical ly as designated by the program when the power is supplied. 1 6-6.the Draining the System foron Relocation/Installation Turn “ON” drainage switch the back side of the product with the power on. . ① This is to be performed with the power plug inserted. 2 3 Manually empty the ice pressing the (ice dispense) touch ② Remove theby lower cover by firstICE pushing the cover down andsensor. the pulling it forward. Turn on the drainage switch, located at the bottom of the panel , Pull out the power plug, 2 bolts attached on the lower to remove waterunscrew remaining inthe the system. ※If the drainage switch is turned on, water and and then front panel , and open it by first pushing thepurification cover down ice production stops. n Drainage switch pulling it towards you. 4 ③ Remove cold water by pressing the water dispense button. In order to remove the water remaining in the cold water tank, tilt Turn on both drainage located at the the panel the productswitches forward and do so until coldbottom water doesofnot come ou to remove t. water remaining in the system. 5 ④ Take out the ice by pressing the ICE(ice dispense) touch senso button. ※If there is no other option but to transport the product in an inclined position, transport the product in a backwards incline detach all hoses (drain, waste water, and water source hoses). position if at all possible. r d If there is no other option but to transport the product in an inclined position, transport the product in a backwards inclined position if at all possible. 15 18 Installation 1 Install the product on a level surface. (Change product level as needed using the product leg adjustment). 2 rarily remove the connector part as provided from your given water source. Then connect the main water line adaptor. If the sealing O-ring at the connection piece is removed or damaged, it can lead to leakage. 3 Connect a tubing hose into water source adaptor and then attach to the water inlet on the rear side of product. tion of the product. 4 Connect tubing hoses into the removed water(brine) and drained water connection part on the rear side of product and then connect tubing hose into the drainage hole in sink, bathroom, or etc. Install the removed water (brine) line and drained water line separately. If drainage does not function properly due to improper installation, then water may flow back towards the waterspout and cause an overflow. 5 Adjust the tubing hoses of the discharged water (brine) and tap water tubing hose so that water does not splash into the surrounding areas. 6 Open the tap water valve supplied into each household, and place the water source adaptor to the open position. 7 Check to see if water is leaking at any connection part. 8 For stabilization of the cooling system and for safe use of the product, insert the power plug into an AC 110V60Hz, 220V50Hz, 240V/50Hz and 220V/60Hz power outlet 30 minutes after installing the product. 9 Check to see whether water is being supplied to the inside of the product and whether there is any leakage in or around the tubing connections. 10 Check whether water is coming out by pressing the water dispensing button 1 9 11 9 19 10 Usage 6. Usage 6-1. Display and System Function Settings(A) 10-1 DISPLAY (A) USB port USB connection can be used to connect diagnostic testing device or to charge USB compatible electronic devices. (Note: Do not charge more than 30 minutes.) ICE FULL Lights up when ice storage is full. (Yellow green) WATER FULL Lights up when ambient water tank is full. (Yellow green) LOCK/HOT Used when setting/releasing the hot water & lock function. A B HOT Water Lock LED HOT water operation LED CONST./ICE Continuous water LED ICE LED Lights up when setting the hot water locking function. (Red) Lights up when setting hot water operation. (Red) Used when setting/releasing the continuous water dispensing & Ice-making. Lights up when setting the continuous water dispensing function. (Red) Lights up when setting Ice-making function. (Red) 6-2. and Water Dispensing Selection(B) 10-2Operation WATER DISPENSING & BUTTONS (B) HOT (Hot water selection) HOT LED (Hot water selection LED) Displays that hot water dispense is set. (Red) COLD/AMBI Used to dispense cold/ambient water. COLD LED (Cold water selection LED) AMBI LED (Ambient water selection LED) Water Dispensing Button ICE (Ice dispenser) ICE LED (Ice dispense LED) 20 12 Used to dispense hot water. Displays that cold water dispense is set. (Blue) ※When no water is in cold water tank, cold dispense selection LED is not turned on water Displays that ambient water dispense is set. (Yellow Green) Used to dispense water into a container such as a cup after selecting the desired water temperature among ambient water, cold water, and hot water. Used to dispense ice. Lights up when dispensing ice. (Red) 6. Usage 10-3Customer OPERATIONAL BEEPSensor 6-3. Warning Action Beep Action Beep ※A beep sound following ICE 500Dang Power ON aerations of the IGUASSU Ding Dong During Power ON Touch Button Division Occurrence RemarksOne / Occurrence Time DingBEEP Dong Dang Ding One Time One Time Remarks/occurrence Lock Ice Making Ding Ding Ding One Time one time Occurrence KeyON/OFF, Input Power Ding~ One Time ON ON/OFF Ding dong dang~ 1During Dispensing Start Ding One Time one time Occurrence Touch Ding~ 2During HotWater Water Lock Button Ding Ding Ding One Time Water ON/OFF, Dispensing Dong One Time one time Occurrence Ding~ding~ding~ Ice Ending making setting ON/OFF 3 Lock setting During Water Intake Start Ding~ One Time Occurrence Ding~ Water intake Start Cont. Water Dispensing Start Ding Dong One Time one time 4 During Water Intake Ending Dong~ One Time Occurrence Dong~ Water intake Ending Cont. Water Dispensing Ending Ding Dong Ding Dong One Time one time 5 ow Water Ding DingDing Ding Ding One Second Interval OverCon. Occurrence one time Ding dong~ intakeError Start 6DuringDrain/Water Level Sensor Ding Ding Ding One Second Interval Occurrence Ding dong~Ding dong~ Water intake Ending 7DuringBeep Ice Con. Discharge Ding~ One Time Sound Setting/Releasing Ding Ding Ding Ding Ding One Time one time One second interval Ding~ding~ding~ding~ Drain/Water level Sensor Error 8 Ding~ding~ding~ding~ding~ Occurrence one time Beep sound Setting/Releasing 9 10-4 SELECTION / DESELECTION FUNCTION Lock Function ( Ice / Hot water locking function) Setting 6-4.1 Function Settings andbutton Releasing Methods Press LOCK/ICE touch sensor softly for over 3 seconds A (1)Lock Function ( Ice / Hot water locking function) Setting Lock lamp(red) is turned on and the lock function is set. 2 ① Touch LOCK/HOT Touch Button softly for over 3 seconds. soundis: Ding~ding~ding~) ② Lock(setting lamp (Red) turned on and the lock function is set. (setting sound : Ding~ding~ding~) Hot water dispensing selection andselection the ice dispensing function ③A hot water intake and the ice dispensing 3 hot water operation, do not after thethe locklock function is set. function dowork not work after function is set. * LOCK functionhelps helps to spout of iceof cube burnsand by hot water.by ※LOCK function toprevent prevent spout iceand cube burns hot water due to user’s carelessness. ② Lock lamp (Red) is turned off and the lock function is. released (releasing sound : Ding~ding~ding~) function is released. 2 ③ A hot water sound operation, hot water intake selection and the ice function work when the (setting : Ding~ding~ding~) setting of Lock Function is released. Hot water dispensing selection and the ice dispensing function 3 (3) Ice-making function setting do not work after the lock function is set. ① Touch CONST button for over 10 seconds. ※As pressing the button, continuous water dispenser function automatically is set after 2seconds and Ice making function setting operates in 10 . Continuous seconds water Ice Making Function Setting dispenser function automatically is released after 5 seconds. Touch CONST button for over 10 seconds. 1 ② ICE LED (Red) is turned on as the ice making function Setting is set. sound: ( Ding~ding~ding~) *As pressing the button, continuous water dispenser function is automatically set after 2seconds and Ice making function setting operates in 10 seconds. Continuous water dispenser function automatically is released after 5 seconds. 2 ICE LED (Red) is turned on as the ice making function is set. (Setting sound: Ding~ding~ding~) Product Usage (2) Lock LOCK Function Releasing Function Release ① Touch LOCK/HOT Touch Button over 3 seconds. 1 Press LOCK/ICE touch sensor button softly softly forfor over 3 seconds 13 21 6. Usage 1 2 Ice Making Function Release Touch CONST button for over 10 seconds. (4) Ice Making function release ① Touch CONST button for over 10 seconds. ② Ice Lamp (Red) is turned off and the ice making function easedis rel (Setting sound: Ding~ding~ding~) (Setting sound: Ding~ding~ding~) * When it is released, remainingremained ice is dispensed the ice storage is being ※When it is released, ice isuntil dispensed untilhouse orage the ice house st emptied. is But emptied. ice-making function is disabled. function is disabled. But ice-making *By pressing the button, water dispenser function is automatically set is after 2 seconds ※As pressing the continuous button, continuous water dispenser function automatically set after and2a setting for the Iceamaking function 10 seconds. Continuous water dispensing seconds and setting of Iceis released makingover function is released 10 seconds. over function is automatically after 5function seconds. automatically is released Continuous waterreleased dispenser fter 5 seconds. a Hot Water Operation Setting (5) Hot water operation setting hot waterLOCK/HOT operation button displayand LEDHot (Red) turned off,erhot system wat operates by byIf touching (hotiswater selection) button simultaneously touching LOCK/HOT button and Hot (hot water selection) button imultaneously s for for over 2 seconds. over 2 seconds. * Hot water system is operated by a detection sensor, which automatically detects the temperature inside of the hot water tank. ※Hot water system is operated by a detection sensor, which atically autom senses the temperature inside of the hot water tank. Hot Water Operation Release If the wateroperation operationrelease display LED is turned on, then the hot water system stops by touching (6) Hothot water If the hot button water operation display LED is turned on, then ot water the h systemforstops LOCK/HOT and Hot (hot water selection) button simultaneously over by 2 seconds. touching LOCK/HOT button and Hot (hot selection) button imultaneously s * Hot water operation/release function operates whenwater LOCK function is enabled. for over 2 seconds. ※Hot water operation/release is enabled. Continuous Water Dispenser function Functionoperates when LOCKnfunctio 1 ProductUsage 2 22 This function is for dispensing ambient/cold water continuously. Touch CONST/ICE (7) Continuous waterthen dispenser function button for 2 seconds, LED (Red) is turned on. ① This function is for dispensing ambient/cold water continuously . Touch CONST/ICE (When the function is set, ambient water is selected by default.) button for 2 seconds, then LED (Red) is turned on. (When nction theisfu set, ambient water is selected by default.) Touch COLD/AMBI button and press Water dispenser button. By doing this, the continuous water ② Touch COLD/AMBI button and press Water dispenser button, ontinuous then c water dispenser function is set with the “Ding-dong” sound to confirm selection. dispenser function is set as sounding "Ding-dong"(While ing dispens water continuously, Water dispenser Button LED is turned off.) * If continuous water dispensing is not utilized in 10 seconds, the function is automatically released. ※If countinuous water dispensing is undone for 10 seconds, unction theisf automatically * Hotreleased. water is not available for continuous dispensing. ※Continuous hot water dispenser is unattainable. Continuous Water Dispenser Function Release While dispensingwater ambient/cold water continuously, the function is released by touching (8) Continuous dispenser function release WhileCOLD dispensing ambient/cold continuously, the selection), function is released by touching either (cold water selection)water or AMBI (ambient water which will be accompanied either COLD (coldsound. water selection) or AMBI (ambient water tion)selec as sounding with a “Ding-Dong” (As continuous water dispenser function releases, LED is turned off). "Ding-Dong" (As continuous water dispenser function ED releases, is turned L off.) Disabling Beep Sound When it is released, HOT/LOCK and CONST/ICE LED lights blink 5 times at one (9) Disabling Beepthe Sound ① If CONST/ICE and HOT (hot water selection) button are pressed t the same a time over second intervals with the continuous sound: “Ding~ding~ding~ding~ding~” 3seconds, beep sound is disabled. 1 2 Enabling SoundHOT/LOCK and CONST/ICE LED are blinking ② When itBeep is released imes by 5 tone second interval with keep " is disabled, press CONT/ICE and HOT (hot water selection) Ding~ding~ding~ding~ding~" While the beep soundsound function buttons at the same time for over 3 seconds. (10) Enabling Beep Sound ① If CONT/ICE and HOT (hotand water selection) button pressed same atat one timesecond over When it is reset, the HOT/LOCK CONST/ICE LED lightsare blink 5the times 3seconds, beep functionsound: is enabled. intervals with the continuous “Ding~ding~ding~ding~ding~” ② When it is reset HOT/LOCK and CONST/ICEare LED blinking 5 times by one second intervalwith keep soundDing~ding~ding~ding~ding~" " 6. Usage 6-5. Ice and Water Dispensing Method CE AND WATER DISPENSING It enables the dispensing when the Lock function is released. It enables to dispense of IceIce andand Hot Hot waterwater when the Lock is function released. ※If Lock(offunction (of water Ice and Hot water dispensing) is dispensing set, water selection touch button * If Lock function Ice and Hot dispensing) is set, Ice dispensing andIce Hot and waterHot functions will not work. don'tafter work. Pleasethe useLock it after releasing of Lock function. Please use them releasing function. Ice Dispensing Mode If ICE(ice dispense) touch sensor button is pressed, the door of the ice storage house is opened and ice comes out from the dispensing hole. B HOT LOCK(hot water lock) Function Release If HOT(hot water selection) touch sensor button is selected and the water dispensing button is pressed, hot water comes out. * Please be careful to avoid burns and use cups when dispensing hot water. * If the hot water operation LED is turned off, hot water will not dispense because the heater is not turned on. Cold Water Dispense Mode If COLD(cold water selection) touch sensor button is selected and water dispensing button is pressed, cold water comes out. HOT(hot water) Operation Release If AMBI(ambient water selection) touch sensor button is selected and water dispensing button is pressed, ambient water comes out. ② Dispense all ice by pressing the Ice dispensing button. ③ Remove the Lower Cover by pressing down and pulling the utward. cover o (Note: May need to remove two screws on the bottom of the r Lowe Cover.) ④ Unscrew both valves (cold and hot/ambient). (See diagram e right) to th ⑤ After dispensing all water and ice from the product, make that sure all valves are closed and the Lower Cover replaced. that sure the product ※During transport, if the product needs to be tilted, make is tilted backwards, no more than 45 degrees. Product Usage * If hot water or ambient water is selected and it is not used for a given time period, the system will automatically switch into cold water dispense mode. (Default function) * There is no separate setting and release method for the use of ambient water/cold water/ice making operation. They operate automatically as designated by the program when power ower is supplied to the unit. ① Turn on the drain switch located on the back of the product. must P be Flushing Valve on for this function to operate. (Note: When drain switch is turned ON, water purification and ice making are disabled.) 15 23 NDERSTANDING THE ICE MAKING PROCESS AND OPERATION The ice making system of the SUPER IGUASSU ICE 900 automatically operates according to the designed program settings when power is applied to the unit. 1 2 3 When power is supplied to the product by inserting the power plug, the ice making process automatically operates without any manual setting. When the level of purified water goes above proper operating levels, all the ice created from the machine will be automatically removed by deicing action. In order to produce cold water, the compressor and circulation pump must operate properly. (The cold water production process automatically operates according to designated programming.) Cold water operation This refers to an operation that makes cold water by continuously circulating and supplying water into the cold water tank. Water temperature in the cold water tank is automatically checked by the cold water temperature sensor, and if it drops below the set temperature, then the cold water operation will automatically stop. 4 If cold water production is operating properly, the ice making system will produce the ice according to the given water supply. Water supply action To supply about .25G(1ℓ) of cold water every 50 seconds into ice making tray in order to make ice. Ice making action ProductUsage Harvest action To an action to separate the ice which was made in the ice tray by supplying hot refrigerant onto the tray. 24 5 When the ice storage is full, the ice detection sensor will automatically stop the process. 6 Cold temperature control is applied to prevent ice cubes from melting by periodically sending cold air into ice storage. 7 If ice in the storage is not used for long periods of time, it may melt, and during ice dispensing, small ice cubes can come out. * TDSs(Total Dissolved Solids) of ice may increase according to the environment in which the ice is created. • Cold water will operate as normal even with the ice making function turned off. • The lower the surrounding temperatures, the shorter the ice making process will take and the higher the surrounding temperatures, the longer the ice making process will take. • Do not install or use the product in temperatures below 32°F(0°C) or above 100°F(38°C). 11 PCB Diagrams 이과수 얼음 냉온정수기 500 ͑͢͢͟;ΒΚΟ͑愕 ͑͢͢͟;ΒΚΟ͑愕 ΁ΠΨΖΣ͑΁ʹͳ͑柦笾壊 ΁ΠΨΖΣ͑΁ʹͳ͑柦笾壊 Main Main PCB PCB 11-1 MAIN PCB v CN9 적색 물받이스위치 Red Drip Tray Switch Sensor POWER PCB 백색 White CN1 Main PCB White CN17 백색 누름 Press버튼 Button CN6 WHT 토출 DOOR Discharging Door 12V BB출력 Output AA출력 Output BOutput B-출력 AOutput A-출력 GND Signal CN12 CN7 GND 1 Black 흑색 ICE만빙센서 Full Sensor Signal 2 GND 1 CN8 청색 Blue 5V 2 ICE만빙센서 Full Sensor Signal 3 CN10 청색 Blue 1 Signal 2 5V CN16 DC12V 1 White 백색 Signal 2 GND 3 PCB Diagrams CCW-Ice making CCW-제빙 GND 주위온도센서 Environ. Temp. Sensor CCW-Ice ejection CW-탈빙 DC5V Environ. Temp 주위온도 CN2 White 백색 디스플레이 Display KEY1 KEY2 COM2 COM1 COM3 COM4 I/O 0 I/O 1 I/O 2 CDS IN DC 12V GND 5V Power GND 온수가동점 Hot re-op. point CN4 백색 White USB Ambi water level 청색 Blue CN5 수위검출기 5V Signal 3 온수 취수 밸브 Hot Dispensing V/V 4 정수 취수 밸브 Ambi Dispensing V/V 5 순환펌프 Circulation Pump 6 온수히터 Hot water Heater 콤프레셔 7 Compressor 8 탈빙릴레이 Ice ejection Relay 9 모터 탈빙방향 Motor-Ice Ejection 모터 제빙방향 Motor-Ice Making 10 토출모터 Discharge Motor 11 탈빙제어소자 12 Ice ejecting Controller 13 정수펌프 Booter Pump 14 GND 15 DC 12V 재가동점point Re-operation 1 급수 밸브 Inlet Valve 2 냉수 취수 밸브 Cold Dispensing V/V 만수Point Water Full point 1 5V 2 GND CN11 흑색 배수스위치 Black Drain Switch 25 이과수 얼음 냉온정수기 500 ͑͢͢͟;ΒΚΟ͑愕 ͑͢͢͟;ΒΚΟ͑愕 ΁ΠΨΖΣ͑΁ʹͳ͑柦笾壊 ΁ΠΨΖΣ͑΁ʹͳ͑柦笾壊 Power Power PCB PCB 이과수 얼음 냉온정수기 500 ͑͢͢͟;ΒΚΟ͑愕 ͑͢͢͟;ΒΚΟ͑愕 ΁ΠΨΖΣ͑΁ʹͳ͑柦笾壊 ΁ΠΨΖΣ͑΁ʹͳ͑柦笾壊 AC21V IN AC21V IN CCW CW Drip Tray Motor 물받이 모터 CN3 Clear 얼음토출모터 COM Ice Making 제빙 CCW CW COM CN6 Clear Ice 탈빙히터 ejection Heater 탈빙 CN4 백색 물받이 모터 CN1 Clear CN5 CN4 Power PCB AC 220 V NC AC 220 V Compressor 콤프레셔 Power PCB CN6 Clear Inlet V/V밸브 급수 백색 CN1 백색 White Main PCB AC21V IN AC21V IN 정수 Pump/ Sol Discharge Motor 토출모터 Motor-Ice Making 모터 제빙방향 Motor-Ice Ejection 모터 탈빙방향 Ice ejection Relay 탈빙릴레이 DC 12V Compressor 콤프레셔 GND Hot water Heater 온수히터 정수펌프 Circulation Pump 순환펌프 탈빙제어소자 Ambi Dispensing V/V 정수 취수 밸브 토출모터 Hot Dispensing V/V 온수 취수 밸브 모터 제빙방향 Cold Dispensing V/V 냉수 취수 밸브 모터 Inlet Valve 급수 밸브탈빙방향 DC24V Ice ejecting Controller 탈빙제어소자 COM Ice ejection 탈빙 제빙 COM Ice탈빙 ejection Heater Heater Hot온수 water HeaterCN6 히터 Clear Ice제빙펌프 making Pump Main PCB 탈빙히터 AC 220 V CN6 청호나이스 환경기술연구소 Clear NC 급수 밸브 탈빙릴레이 콤프레셔 - 26 온수히터 순환펌프 정수 취수 밸브 온수 취수 밸브 냉수 취수 밸브 냉수 밸브 온수 밸브 정수 밸브 DC24V PCBDiagrrams Sol DC 12V GND Booter Pump 정수펌프 Cold water V/V 냉수 밸브 Hot water V/V 온수 밸브 Ambi V/V 정수water 밸브 DC24V 26 Clear CN5 White 백색 정수Pump/ Pump/ Ambi Sol. DC24V CN3 Clear Motor-Ice Ejection 얼음토출모터 Power 11-2 power pcb Power PCB PCB AC 220 V 콤프레셔 탈빙 Heater 온수 히터 12 Examination/Repair Procedure No Malfunction Page 1 Power 28 2 Refrigerant Leak 29 3 Water Leak 30 4 Filtration Malfunction 31 5 Inlet Sol V/V Defect 32 6 Cold/Ambi/Hot Water Sol V/V Defect 33 7 Product Level Defect 34 8 Drainage 35 9 Hot Water Part Malfunction 36 10 Circulation Pump Defect 37 11 Tray Motor Coupler 38 12 Micro Switch Ass'y - Synchronous Motor 39 13 Cold Water Level Sensor Defect 40 14 Display Module Defect 41 15 Cold Water Temperature Sensor Defect 42 16 Ice Full Sensor Defect 43 17 Ice Full LED Defect 44 18 Main PCB 45 19 Power PCB 46 20 Function/Dispensing Selection PCB 47 21 Tray Motor/Micro SW Change 48 22 Circulation Pump/ Cold Temp Sensor Change 49 23 Sensor Table 50 27 POWER Power plug is inserted into a wall outlet but no LED lights. * Caution: Never touch electrical parts with wet hands TroubleShooting How to Diagnose 28 1 Open the Front Lower Panel and Check the Input Voltage (AC 110V). > If no input electric current, replace the power cord. 2 Check the Fuse location, and see if the Fuse (inside the Fuse holder) is open. (Fuse: AC110V/8A) > Replace the fuse, if it is open. 3 Uncover the Front Middle Cover and check the IN/OUT sockets and voltage of the transformer. - INPUT: AC110V (Wire: Black color) - OUTPUT: AC21 (Wire: Red color) > Replace the T/R if defected. 4 Check if power(DC 12V) goes to the Main PCB, and check all wire connections. > Replace the Power PCB if defective. > Replace the Main PCB if normal. EFRIGERANT LEAK How to Diagnose 1 Touch the back grill with your hand to determine temp. (During Ice Making 100ºF ~ 140ºF : Hot) 2 Coolant leak occurs at welding areas as marked below, check with the power meter. - If there is a leak, very low power (100W or below) is detected. ** Please note that when the ice is releasing, the grill and dryer will be cold. Trouble Shooting 29 WATER LEAK 1 Make sure the water source is connected to the very bottom hole. Drain Outlet Waste Water Outlet TroubleShooting Water Source Inlet 30 2 Open the Top Cover and Front Upper cover to check if there is any water around the Level Sensor’s Tube Cap or the Medium Filter on the ambient tank. Wipe any remaining water. Also make sure if the 3 While the system’s power is off, disconnect the hose between the water inlet sol v/v and the pump to check if it leaks. Open the Top Cover and Front Upper cover to check if there is any water around the Level Sensor’s Tube Cap or the Medium Filter on the ambient tank. Wipe away any remaining water. Also make sure that the silicon is firmly attached to those parts. > Replace the water inlet sol v/v ass’y if it leaks. FILTRATION MALFUNCTION Check to make sure that the Level sensor and filtration processes work properly. Check if the water supply valve is open. 2 Check if water comes out of the membrane. 3 Open the Front lower panel to check if the booster pump works properly. > If so, replace Membrane Ass’y. > If not, check Power PCB. 4 Open Front Middle Cover and check the output voltage of CN1 and CN5 on the Power PCB. Output Voltage: Replace the Sol V/V No output voltage: Power PCB Trouble Shooting 1 31 12-5 INLET SOL V/V DEFECT TroubleShooting A faulty inlet solenoid valve causes water dispensing malfunction by not supplying water to the cold water tank. 32 1 Check hot/cold/ambient water dispensing solenoid valves. - Check to see if its voltage is DC24V at terminal when dispensing. > If not, replace Sol V/V > No output: check Main PCB, Power PCB 2 - Check if there is leak at the Sol V/V. - Check wire connections. 3 Check output voltage at CN3 on Main PCB. > Replace Main PCB if no output volatage. > Replace Power PCB if output volatage. COLD/AMBI/HOT WATER SOL V/V DEFECT A faulty water dispensing solenoid valve (Hot/Cold/Ambient) causes malfunctions in dispensing water. Cold 1 Hot Check hot/cold/ambient water dispensing solenoid valves. - Check to see if its voltage is DC24V at terminal when dispensing. > If not, replace Sol V/V - Check if there is a leak at each SolV/V - Check wire connection Red : Hot Water Dispensing Sol V/V White : Ambient Blue : Cold If voltage DC24V is not being supplied, check the controller and wire connection. - Check wire connection - Check output voltage at controller. > Replace Controller if it is faulty. Ambient Trouble Shooting 2 33 RODUCT LEVEL DEFECT TroubleShooting If the product is not properly leveled, it may cause ice to over freeze and/or freeze irregularly. 34 1 Check the product’s level by using a level detector which is located under the drip tray. 2 Set the level accordingly. (Water leak may occur if the product’s level is off by more than 3 degrees.) DRAINAGE 1 working properly. Water goes out to drainage outlet, - When water is dispensed, water goes out through the drip tray. - When Ice melts from the storage Check the connection to see if it is bent or twisted. (Check also the 3/8” Equal Tee and 3/8” BulkHead) 3 Check if drain works properly. (If not, a drain pump must be installed) Drain Outlet Waste Water Outlet Water Source Inlet Trouble Shooting 2 35 12-9 HOT WATER MALFUNCTION If the hot water overheats, the ambient tank’s temperature goes up could cause an overflow. Check the electric resistance of the hot water temp-sensor and manual bimetal. 1 Hot water temp-sensor : Check electric resistance. Auto Bimetal : 90N (Max 199.4°F) °F) 2 water tank’s surface. Top: Automatic bimetal Bottom: Manual 3 Automatic Press the Reset Button of the manual bimetal. TroubleShooting Reset Button 36 Manual 4 Check heater wire connection and applied voltage. - Applied Voltage : AC 220V IRCULATION PUMP DEFECT Check for any foreign objects inside the circulation pump. Open the Front middle cover to check the circulation pump located at the bottom right. - Voltage check: AC220V/60Hz * Empty the cold tank before detaching the circulation pump from the body - Drain cold water by opening cold cleaning valve. - Detach EPS - Detach the Circulation pump by rotating it 90° clockwise. * Voltage is applied and not rotating, replace the Circulation pump. 2 Check if any foreign object inside the circulation pump. 3 Check for leakage around the rubber ring on the pump head. 4 Trouble Shooting 1 37 RAY MOTOR COUPLER TroubleShooting Tray motor coupler may be broken due to bridge-shaped ice, circulation pump defect, and ice rejection malfunction. 38 1 Open Front upper panel to check the Synchronous Motor. Applied volatage : AC220V/60Hz 2 Detach the motor to check the motor coupler for breakage. 3 Rotating Drip Tray + Motor coupler + Synchronous Motor. 4 Attach Motor coupler on the Synchronous Motor. ICRO SWITCH ASS’Y YNCHRONOUS MOTOR Defects on the Micro Switch Ass’y of the Synchronous Motor can cause malfunctions for the ice making and cold water making processes. Open Front upper panel to check the switch of Synchronous Motor. (Micro Switch 2EA) 2 Check the lever and connections of the drip tray motor. > Replace parts accordingly if faulty. 3 Switching time from Ice making S/W to Ice rejection S/W is normally under 16 seconds. - Avg. 16 sec. from ice-rejection to making. 4 Water drops onto Main PCB cause malfunctioning. > If water leaks onto the board, replace Controller PCB. Trouble Shooting 1 39 OLD WATER LEVEL SENSOR DEFECT Defects on the cold level sensor cause either no supply or over-supplying of water to the cold tank. > Replace it if faulty. 1 Check cold water level sensor by opening the front middle cover. TroubleShooting check after replacing the cold level sensor. 40 2 Detach hot/cold sol V/V Ass’y and the cold level sensor. 3 Cold water level sensor - 3 lines : GND, Signal, DC12V * GND helps stabilizing the voltage. - When the cold tank is full, the sensor detects this and stops the water supply to the cold tank. 4 The Inlet sol V/V is defective when the cold water level sensor is appears to be faulty. (If water comes into cold tank over 5 minutes, and the cold tank is not full, then the Cold tank is faulty.) ISPLAY MODULE DEFECT Display or touch buttons may not work due to poor connections and the PCB assembly. Function PCB - Check wires and connections - Check the sponge inside - Check for humidity inside 2 Dispensing PCB - Check for residual water and remove if any 3 Ice ejection PCB - Check for residual water and remove if any - Check wires and connections 4 Check in/out wire connections of all PCBs. AS Procedure If malfunctions occur on touch buttons and/or LEDs of the front display, replace Front Upper Ass’y. Trouble Shooting 1 41 OLD WATER TEMPERATURE SENSOR DEFECT TroubleShooting A Faulty cold water temperature sensor causes the malfunction of the cold water and ice making processed. - When open: reconnect it if disconnected, and replace the sensor if defective. - When short: Replace the sensor 42 1 Check the cold water temperature sensor by opening front middle panel. - 3PIN : 5V, Signal, GND - GND is connected to the bracket screw in order for the sensor to work properly. 2 Detach circulation pump Ass’y and EPS to locate the cold water temperature sensor. 3 Pull out the sensor by removing circulation pump head and heating insulation. (O-ring inside, check for leakage) 4 Cold water temperature - left: sensor pole, right: GND G Ground 5 Defects display when Coolant leakage and the cold water process continues for 60 minutes, 3 consecutive times. - left: sensor pole, right: GND G CE FULL SENSOR DEFECT When display’s Ice Full LED is on when the ice storage is not full, or when the Ice Full LED does not turn on when the ice storage is full. > Replace the sensor if faulty. 1 Sensor(TX) at the bottom left of the water tank, Sensor(RX) at the bottom right of the water tank. Ice full transmits for 7 seconds by pressing Ice dispensing button. - Check malfunction of the ice full sensor. 3 2 Pin housing - White : Transmitting part - Black : Receiving part (located on the back of the unit) White Black Trouble Shooting 2 43 CE FULL LED DEFECT 1 TroubleShooting Synchronous Motor. (inside EPS) - Ice Full LED Blinking : exceeding detection time (60 sec) - Ice Full LED Blinking : S/W pressed simultaneously (60 sec) 44 2 - Ice Full LED blinking : when environmental sensor is faulty - Cold selection LED blinking : when cold water sensor is faulty - Ice Full LED blinking : when circulation pump is faulty - Ice Full LED blinking : when inlet sol v/v or cold water level sensor is faulty 3 Ice Full LED blinks when the ice making time is shortened by half and it occurs for 3 consecutive times due to over cooling. (This is caused by the breakage of the tray motor coupler, defective circulation pump, and/or malfunction on ice rejection.) Ground 12-18 Main PCB 1 Unscrew bolts from the top cover and the rear panel (2EA). 2 Unscrew bolts from the side panels. (2ea) 3 Disconnect wires on the front upper panel from the Main PCB controller. 4 Disconnect all wires and unscrew bolts from the Main PCB (4EA). Trouble Shooting Black 45 Trouble Shooting 12-19 Power PCB 46 44 1 Unscrew bolts from the front lower panel. 2 Unscrew bolts from the front middle panel. 3 Unscrew bolts from the Power PCB case. Ground 4 Disconnect wires and unscrew bolts from the Power PCB. 12-20 Function/Dispensing Selection PCB Detach top cover (2 screws), and front upper panel (2 screws). Disconnect wires from the front upper panel as marked with yellow circles, and unscrew the bolts (marked as red circle, 7ea). 2 Separate the front upper deco and front upper body by pressing the hooks of the front upper deco. 3 Unscrew 4 bolts from function PCB. 4 Replace Front Upper Ass’y when Dispensing Selection PCB is faulty. Trouble Shooting 1 47 45 Trouble Shooting 12-21 Tray motor/Micro SW Change 48 1 Open top cover and front upper panel. 2 Remove or replace the rotating drip tray. 3 Detach front middle cover, Power PCB case, and disconnect Tray motor connection. 4 Replace Micro Switch. 12-22 Circulation Pump/Cold Temp Sensor Change Remove Top cover/Front upper panel/Front lower/ front middle panel, and also remove 2 EPS around the circulation pump. 2 Detach Ambient dispensing sol V/V, and detach circulation pump by rotating it clockwise. 3 Detach Circulation pump head and EPS. 4 Replace circulation pump and cold water temperature sensor. Trouble Shooting 1 49 12-23 Sensor table 12-23-A. Ice Making Temp sensor, Cold Water Temp sensor Table (°F) (KΩ) (°F) (KΩ) (°F) (KΩ) -22 117 41 22.2 104 5.8 -13 90 50 18.1 113 4.9 -4 70 59 14.7 122 4.1 5 55 68 12.1 131 3.5 14 43.3 77 10 140 3 23 34.5 86 8.3 149 2.6 32 27.6 95 6.9 158 2.2 Trouble Shooting 12-23-b. Environment sensor Table 50 (°F) (KΩ) (°F) (KΩ) (°F) (KΩ) -22 885 41 127 104 26.6 -13 652 50 99.5 113 21.8 -4 485 59 78.5 122 18 5 364 68 62.5 131 14.9 14 276 77 50 140 12.4 23 211 86 40.3 149 10.4 32 170 95 32.6 158 8.7 12-23-C. Ice Making Temp sensor, Cold Water Temp sensor Table °F Ice Making Time (minute) 32 6.5 41 6.5 50 6.5 °F Ice Making Time (minute) 59 6.5 68 7.5 77 9 °F Ice Making Time (minute) 95 12 104 13 113 21 이과수 얼음얼음 냉온정수기 500 500 이과수 냉온정수기 Flow Charts ͤ͑͢͟ͷΝΠΨ͑ʹΙΒΣΥ ͤ͑͢͟ͷΝΠΨ͑ʹΙΒΣΥ ͤ͑͢͟ͷΝΠΨ͑ʹΙΒΣΥ ͤ͑͢͟ͷΝΠΨ͑ʹΙΒΣΥ ͤ͑͢͟ͷΝΠΨ͑ʹΙΒΣΥ 이과수 얼음얼음 냉온정수기 500(CHP-5110S) ͤ͑͢͟ͷΝΠΨ͑ʹΙΒΣΥ 이과수 냉온정수기 500(CHP-5110S) MAIN 루틴루틴 MAIN 13-1 MAIN FLOW CHART M2 M2 이과수 얼음 냉온정수기 500(CHP-5110S) 배수 Drain시스템 System 배수 시스템 MAIN 루틴 Delay Delay Ice Full, Water Full, Yes Yes 만빙, 만수, 잠금, 만수, 배수 Switch On? Drain Switch On? On? Lock, Hot만빙, water, Cost.잠금, 배수 Switch 온수, 연속 온수,LED 연속점멸 LED 점멸 M2 LED 시스템 blinking 배수 No M1 시스템 초기화 Compressor 4분 M1 Delay 잠금 &잠금 온수& 온수 이과수 Mode Mode CheckCheck 얼음 냉온정수기500 (CHP-5110S) 잠금&온수 Mode Check 13-2 Lock & Hot water 서브루틴 No Mode Check Sub Routine STARTSTART System Initiation 시스템시스템 초기화초기화 Compressor 4분 min 4분 START Compressor 13 이과수 얼음얼음 냉온정수기500 이과수 냉온정수기500 (CHP-5110S) 잠금&온수 Check (CHP-5110S) 잠금&온수 Mode Check 500 이과수Mode 얼음 냉온정수기 서브루틴 서브루틴 No 정수 water 수위체크 Check level 정수Switch 수위체크 배수 On? 동작 및시스템 동작 시스템 &및 Operating Sys. 3초 이상 3초 이상 No ButtonButton On? On? 잠금 & 온수 Lock & Hot Water Mode Check No No 온수 설정 온수상태 설정반전 상태 반전 No 0.5초이상 0.5초이상 ButtonButton On? On? 잠금 설정 잠금상태 설정반전 상태 반전 Button on 3초 이상 Button On? over 3 sec? No Yes Yes 0.5초이상 Button on Button over 0.5 On? sec? 잠금 setting 설정 상태 반전 Lock Inversed Yes 만빙, 만수, 잠금, 온수, 연속 LED 점멸 END END Yes Hot설정 water상태 setting 온수 반전 Inversed No M1 Lock & Hot water 잠금 &잠금 온수 & 온수 Mode Mode CheckCheck 잠금 & 온수 Mode Check 정수 수위체크 및 동작 시스템 Hot water 온수 시스템 온수 시스템 system 온수 시스템 Cold water 냉수 시스템 냉수 시스템 system Compressor Off Off Compressor 원수 Sol Off Water source Sol OffOff 원수 Sol 냉수급수 SolSol OffSol Cold water inlet Off Off 냉수급수 Pump OffOff Off Ice제빙 Making Pump 제빙 Pump 온수 Off Hot water Off Off 온수 Compressor Off 원수 Sol Off 냉수급수 Sol Off 제빙 Pump Off 온수 Off END 이과수 얼음 냉온정수기 (CHP-5100S) 이과수 얼음 냉온정수기 (CHP-5100S) 만빙Ice 검출 Sensor Check 서브루틴 만빙 검출 Sensor Check 서브루틴 13-3 full detection sensor Check Sub Routine 만빙 만빙 검출 Ice검출 Full detection Sensor CheckCheck Sensor 이과수 얼음 냉온정수기 (CHP-5100S) 만빙 검출 Sensor Check 서브루틴 초기 전원 Power 초기 전원 인가시? 인가시? just on? 만빙 No 검출 No Sensor Check 탈빙완료 탈빙완료 직후? Ice 직후? just ejected? Ice 만빙 Full detection 검출 만빙 검출 SensorSensor CheckCheck 냉수 시스템 Ice making/ 제빙/탈빙 시스템시스템 제빙/탈빙 realeasing system 초기 No 전원 No 인가시? 얼음토출 Ice얼음토출 dispensing No 버튼 누름? 버튼 누름? button on? No No 탈빙완료 직후? 만빙 검출 Sensor Check Dispensing 시스템 취수제빙/탈빙 시스템 취수 시스템 system Continuous 취수 시스템 연속취수 시스템 Dispensing 연속취수 시스템 system Error Status Error Status CheckCheck Error Status Check M2 M2 연속취수 시스템 Ice dispensing 얼음 토출 얼음시스템 토출 시스템 system 얼음 토출 시스템 M1 M1 Yes Yes Yes Yes Yes Yes For 7 Seconds 얼음토출 Ice얼음토출 dispensing Yes Yes TX 7초간 송출 (PWM) TX transmitting TX 7초간 송출 (PWM) No 버튼 해제? 버튼 해제? button off? (PWM) 얼음토출 Yes 버튼 누름? No No Yes Yes 5초 이상 Ice Full over 5초 이상 No 얼음검출? 얼음검출? 5 sec? Yes 얼음토출 TX 7초간 송출 (PWM) No No 버튼 해제? 만빙? 만빙? Ice Full? Yes Yes No every min. 10분 주기로 10분 10 주기로 For 7 Seconds TX 7초간 송출 (PWM) TX 7초간 송출 (PWM) TX Receiving (PWM) No No 5초 이상 얼음검출? Yes No 만빙? Ice Full Yes Yes 만빙해제 만빙해제 Full LEDOff Off 만빙 Ice LED Off realeased 만빙 LED Yes 검출 5초? 검출 5초? No 5 sec? 10분 No 주기로 No TX 7초간 송출 (PWM) 만빙 LED On 만빙 Ice FullLED LEDOn On 일반보냉실시 일반보냉실시 Normal cold-insulated op.(주위온도별) (outside temp.) (주위온도별) Yes 만빙해제 만빙 LED Off 검출 5초? No END END 만빙 LED On 일반보냉실시 (주위온도별) M2 Yes Yes 51 이과수 얼음 냉온정수기 500 ͤ͑͢͟ͷΝΠΨ͑ʹΙΒΣΥ ͤ͑͢͟ͷΝΠΨ͑ʹΙΒΣΥ 이과수 얼음 냉온정수기 (CHP-5110S) Error Status Check 서브루틴 13-4 error status check SUBROUTINE Error Status Check Ice making & cold 제빙&냉수시스템 system stop정지 정수 , 온수 Ambi, Hot정상가동 normal operation Yes Cold water 냉수온도센서? temp. sensor No Ice making & cold Yes 제빙&냉수시스템 system stop정지 정수 , 온수 Ambi, Hot정상가동 normal operation Yes Open & Short Overheating 과열 Environment 주위온도센서? temp. sensor No 제빙시스템 정지sys. 70도 Ice making 이하시 재가동 , stop. rerun if under 제빙기능 158시간으로 ‘F 동작function Ice making Open & Short 80도 이상 Over 176’F Open & Short Ice making 제빙온도센서? temp. sensor Water level 정수수위 센서 불량? sensor defect? Ice Full LED blinking 만수 LED 점멸 Beep (Ding~ Ding~ Beep(딩~딩~딩~) Ding~) Yes No Ice ejection <-> Ice making 탈빙위치↔제빙위치까지 for 60이상 seconds 60초 지속, 탈빙/제빙 위치 모두 검출 detectect ice ejection/making Drip tray위치 loca물받이 tion detection 검출불량? defect? Yes Ice만빙 Full LED LED blinking 점멸 No Flow Charts Yes 52 Complete ice제빙시간의 making process 주위온도별 in half이하로 time as제빙완료 normal 절반 3 consecutive 연속 3회 검출? times? 5시간 Clear 5 hrs. Error error clear 탈빙동작 Ice Ejection Yes No No 3 consecutive 연속 3회 검출? times? No 과냉Cooling? 발생? Over Yes Yes 제빙 Pump Ice making 불량? pump defect? No Yes Ice making/Cold 냉수/제빙 시스템 system Off Off Ice만빙 Full LED LED blinking 점멸 - reach ice making temp. while making 냉수동작 중 주위온도별 cold water process 제빙설정 온도에 먼저 도달 - Over 60 min. of cold water process 냉수동작이연속 60분 이상 초과 급수 Solv/v 열린 시간이 Inlet sol open over 5누적 min.5분 total 이상일 경우 (냉수수위센서불량) (cold level sensor defect) 급수Inlet SolSol 불량? defect? No END - 53 - 청호나이스 환경기술연구소 이과수 얼음 냉온정수기 500 이과수 얼음 냉온정수기 500500 이과수 얼음 냉온정수기 ͤ͑͢͟ͷΝΠΨ͑ʹΙΒΣΥ ͤ͑͢͟ͷΝΠΨ͑ʹΙΒΣΥ ͤ͑͢͟ͷΝΠΨ͑ʹΙΒΣΥ ͤ͑͢͟ͷΝΠΨ͑ʹΙΒΣΥ ͤ͑͢͟ͷΝΠΨ͑ʹΙΒΣΥ ͤ͑͢͟ͷΝΠΨ͑ʹΙΒΣΥ 이과수 얼음 냉온정수기 500(CHP-5110S) 이과수 얼음 냉온정수기 500(CHP-5110S) 이과수 얼음 냉온정수기 13-5 level & op. 정수check 수위 Check 및 subroutine 동작500(CHP-5110S) 서브루틴 정수 수위 Check 및 동작 서브루틴 정수 수위 Check 및 동작 서브루틴 Check water level 정수 수위 Check 수위시스템 Check 및 동작 정수 수위 Check &정수 Operating Sys. 냉수 시스템 Water 냉수Cold 시스템 냉수 시스템 및 동작 시스템 및 동작 시스템 Water이상? Full 만수 Abnormal? 만수만수 이상?이상? No No No Power just 초기가동? on? 초기가동? 초기가동? 이과수 얼음 냉온정수기 500(CHP-5110S) 이과수 얼음 냉온정수기 500(CHP-5110S) 이과수 얼음 냉온정수기 500(CHP-5110S) 시스템 서브루틴 13-7 cold냉수 water system subroutine 냉수 시스템 서브루틴 냉수 시스템 서브루틴 System Booster Pump, 정수 Pump, 정수 Pump, 원수 밸브 Off Water Source Valve Off 정수 Pump, 원수 밸브 Off 만수Full LED OnONOff Water LED 원수 밸브 만수만수 LED LED On On Yes Yes Yes 냉수 수위 냉수 수위water 만수? 냉수 수위 Cold 만수? 만수? full? Yes Yes Yes Yes Yes Yes No No No 냉수 급수 밸브 Off 냉수냉수 급수water 밸브밸브 Off Sol Cold inlet 급수 Off V/V Off Yes Water 재가동 Level 수위가 Yes Yes 수위가 재가동 이하? Below rerun? 수위가 재가동 이하? 이하? No No No No No No 만수Full LED ONON Water LED 만수 LEDOFF ON 정수 동작 Off ON Filtration 만수 LED 정수정수 동작동작 Off Off No No No 냉수 급수 밸브 On inlet 냉수Cold 급수water 밸브밸브 On Sol 냉수 급수 On V/V ON Filtration 정수 동작ON On Water Full LED 정수정수 동작 On On 만수 LED OFF 동작 OFF 만수만수 LED LED OFF OFF 냉수 4도 냉수 4도 water 이하? Cold 냉수 4도 이하?이하? below 39’F? No No No END ENDEND No No No Comp 재가동? Comp 재가동? Comp Comp재가동? ON? 이과수 얼음 냉온정수기 500(CHP-5110S) 이과수 얼음 냉온정수기 500(CHP-5110S) 이과수 얼음 냉온정수기 500(CHP-5110S) 온수 시스템 서브루틴 온수 시스템 서브루틴 온수 시스템 서브루틴 13-6 hot water system subroutine Yes Yes Yes 냉수 5도 냉수 5도 water 이상? 냉수 5도 Cold 이상?이상? over 41’F? No No No 온수 시스템 온수온수 시스템 시스템 Yes Yes Yes No No No Yes Yes Yes 온수 Mode? Hot ON water ON 온수 ON Mode? 온수 ON Mode? mode? Compressor On Compressor On On 제빙Compressor Pump On Compressor ON 제빙 Pump On On (냉수 가동) 제빙 Pump Ice making Pump ON (냉수(냉수 가동)가동) (Cold water On) No No No Compressor 5분 Off Compressor 5Off min Off Compressor 5분Off 냉수급수밸브 Compressor 5분 Off Cold water inlet v/v Off 냉수급수밸브 Off 순환 Pump 5분 On 냉수급수밸브 Off Circulation pump 순환(냉수 Pump 5분 On 정지) 순환 Pump 5분 On 5min ON (냉수(냉수 정지)정지) (Cold water On) Yes Yes Yes Heater On Heater On On (온수 가동) Heater (온수 가동) (온수 가동) (Hot water On) Heater Off Heater Off Off (온수 정지) Heater (온수 정지) (온수 정지) (Hot water Off) END ENDEND END ENDEND - 54 54 -- 54 Flow Charts 수위가 Water 재가동이상? Level Below 수위가 재가동이상? 수위가 재가동이상? rerun? 청호나이스 환경기술연구소 청호나이스 환경기술연구소 청호나이스 환경기술연구소 53 이과수 얼음 냉온정수기 500 ͤ͑͢͟ͷΝΠΨ͑ʹΙΒΣΥ ͤ͑͢͟ͷΝΠΨ͑ʹΙΒΣΥ 이과수system 얼음 냉온정수기 500(CHP-5110S) 13-8 ice making & ejection subroutinE 제빙, 탈빙 시스템 서브루틴 YES Ice만빙? Full? NO YES Cold water 냉수온도 5.5이하? below 42’F? NO Cold water 냉수온도 5.5이하? below 42’F? Cold water 냉수온도 4도이하? below 39’F? 순환 Pump OnON Circulation pump Comp. On Comp. ON YES Comp. Comp.OFF Off TrayIce ejection loc. 물받이 탈빙위치 순환 Pump OnON Circulation pump Comp On Comp. ON NO NO NO 냉수수위 Cold water 만수? Full? Cold water 냉수온도 4도 이하? below 39’F? YES YES Circulation pump 45 순환펌프 45초 On sec. ON Comp. On Comp. ON NO Circulation pump 순환 Pump Off OFF Comp. Off Comp. OFF YES Comp. OFF Comp. Off Circulation5분 pump 순환펌프 On 5min OFF YES 제빙온도 Ice making temp. 센서 불량? sensor defect? NO TrayIce ejection loc. 물받이 탈빙위치 NO Ice making 제빙시간 time done? 완료? 완료? Ice 제빙 making done? (온도/시간) (temp./time) Flow Charts YES 54 NO YES Tray moves to ice 물받이 탈빙위치 이동 ejcetion location 탈빙 히터 ON ON Ice ejection Heater (5도or ) (41’F or 55분 min) Comp Off Comp OFF 물받이 제빙위치로 Tray moves to ice making location 이동 END - 55 - 청호나이스 환경기술연구소 이과수 얼음 냉온정수기 500 ͤ͑͢͟ͷΝΠΨ͑ʹΙΒΣΥ ͤ͑͢͟ͷΝΠΨ͑ʹΙΒΣΥ 이과수 얼음 냉온정수기 500(CHP-5110S) 13-9 dispensing system subroutine 취수 시스템 서브루틴 Dispensing 취수 시스템 System Dispensing 취수 Button Off? button OFF? Yes 취수 중? Dispensing? No Ambi dispens정수취수 선택? ing selected? Yes Ambi disp.Mode Mode Set Set 정수취수 Ambi 정수 LED ON On 온수, 냉수LED LEDOFF Off Hot, Cold No Hot dispensing 온수취수 선택? selected? Yes Yes 온수취수 Mode Set Set Hot disp. Mode 온수 LEDON On Hot LED 냉수,Ambi 정수 LED LEDOFF Off Cold, No Cold dispens냉수취수 선택? ing selected? Yes 냉수취수 Cold disp. Mode Mode Set Set 냉수 LED LED ON On Cold 정수, 온수 LEDOFF Off Ambi, Hot LED No Ambi dispensing 정수취수 Mode? mode? No 10초 over 10경과 sec. over 5 sec. 초 5 경과 Const. 연속취수 dispensing 3분 이상? over 3 min? Hot dispensing 온수취수 Mode? mode? Yes Ambi, Hot, Cold 정수,온수,냉수 Sol Valve OFF Sol-valve Off No Dispensing 취수 Button On? button ON? No Yes Ambi dispensing 정수취수 Mode? mode? Yes Ambi water Sol 정수 Valve Sol-valve ON On Cold 10초water 경과Disp. 후 ModeMode Set Set 냉수취수 after 10 Sec. No Hot dispensing 온수취수 Mode? mode? Ambi, Hot, Cold 정수,온수,냉수 Sol-valve Off Sol Valve OFF Yes Ambi dispensing 정수취수 Mode? mode? No Yes Hot water Sol Valve 온수 Sol-valve On ON Cold LED ON 냉수 On 정수, LEDOFF Off Ambi, 온수 Hot LED No Cold water Disp. 5초 경과 후 ModeMode Set Set 냉수취수 after 5 Sec. No Cold water SolOn 냉수 Sol-valve Valve ON END - 56 - Yes Hot dispensing 온수취수 Mode? mode? Flow Charts Cold 10초water 경과Disp. 후 ModeMode Set Set 냉수취수 after 10 Sec. 청호나이스 환경기술연구소 55 이과수 얼음 냉온정수기 500 ͤ͑͢͟ͷΝΠΨ͑ʹΙΒΣΥ ͤ͑͢͟ͷΝΠΨ͑ʹΙΒΣΥ 이과수 얼음 냉온정수기 500(CHP-5110S) 13-10 constant dispensing system subroutinE 연속취수 시스템 서브 루틴 Start 연속취수버튼입력 Const. dispensing Button over 2 sec? 2초이상? Yes 연속취수 후 버튼the누를 때마다 1~3반복 Repeat 1~3설정 as pressing button after setting Const. Dispensing setting (해당 LED 로is 연속취수용량설정 ) (Set amount shown in each LED) ON/1.0ℓ 1.1. 0.5l0.5ℓ ON/1.0l OFF OFF OFF/1.0ℓ ON 2.2. 0.5l0.5ℓ OFF/1.0l ON 3.3. 0.5l0.5ℓ OFF/1.0l OFF OFF OFF/1.0ℓ (On “3”, it goes to normal dispensing mode일반취수동작) upon pressing dispensing button ( 3의 상태에서 취수버튼 누름시 연속취수 LEDON ON Const. LED 정수 AmbiDefault Default Cold water selected? No 냉수선택? Yes No No Cold/Ambi disp. 냉/정수취수버튼 button input? 1st 1st 입력? Cold/Ambi disp. 냉/정수취수버튼 button input? 1st 1st 입력? Yes Yes 정수취수 Ambi Dispensing SOL. V/V ON ON Sol. V/V 설정시간초과? Setting time over? Cold Dispensing 냉수취수 Sol. V/V SOL. V/VON ON Yes 설정시간초과? Setting time over? Flow Charts No 56 Const. Button or 연속취수버튼 Cold/Ambi Selection Btn 냉/정수선택버튼 or or Ambi Button 2nd input? 정수취수버튼 2nd입력? No Yes No Const. Button or 연속취수버튼 or Cold/Ambi Selection Btn 냉/정수선택버튼 or or Ambi Button 2nd input? 냉수취수버튼 2nd입력? Yes No Yes No 정수취수 Ambi Dispensing SOL. OFF Sol. V/V V/V OFF 냉수취수 Cold Dispensing Sol. V/V V/V OFF SOL. OFF END - 57 - 청호나이스 환경기술연구소 이과수 얼음 냉온정수기 500 ͤ͑͢͟ͷΝΠΨ͑ʹΙΒΣΥ ͤ͑͢͟ͷΝΠΨ͑ʹΙΒΣΥ 13-11 ice ejection system subroutine 이과수 얼음 냉온정수기 500(CHP-5110S) 얼음토출 시스템 서브루틴 토출 시스템 Ice얼음 ejection system Ice 얼음토출 dispensing Button ON? On ? button Yes Door MotorOn ON Door Motor MotorMotor On ON after 1초후 1 sec.토출 Ejection 얼음 On Ice토출 LEDLED OFF No 얼음토출 Ice dispensed? 했나? Yes Yes 3분 이상 경과? Over 3 min.? No Ejection motor 토출 Motor Off OFF 1초 이상 경과? Over 1 sec.? No No Yes Flow Charts DoorMotor Motor OFF Off Door 얼음 LEDOFF Off Ice LED END - 58 - 청호나이스 환경기술연구소 57 ChungHo USA 16590 Aston St. Irvine CA 92606 888.758.1234 www.chunghousa.com [email protected]