iJB Series 60A Non-isolated SMT Point of Load with PMBus Features  Only 1.0 in2 Board Space  PMBus Compliant (Read & Write)  Surface Mountable  Digital Adaptive Control  Parallel Operation with Current Sharing  Configurable Sequence & Fault Management Key Market Segments & Applications Specifications Model DC Output Voltage DC Output Power (max) DC Input Voltage Efficiency Output Voltage Tolerance Line Regulation Load Regulation External Load Capacitance Output Ripple and Noise Overcurrent Protection (Typ) Remote On / Off Remote Sense Power Good Operating Temp Storage Temperature Safety Agency Approvals Weight Size (LxWxH) Warranty iJB12 V W V % % mV mV uF mVpp A °C °C g / oz mm / in. yrs 1-800-526-2324 • www.us.tdk-lambda.com/lp/ 0.6 - 2.0V 120W 8 - 14V 85 - 93% ±1.2 4 (Typical) 4 (Typical) 1000 - 5000 20 65A Negative Logic or Positive Logic (See model selector) Yes Yes -40 to 120 (see thermal data on website) -55 to 125 IEC/EN/UL/CSA 60950-1, CE MARK 12.2g / 0.43 oz 26.8 x 24.08 x 9.68 (1.05 x 0.95 x 0.381”) 3 years 214 Disclaimer: us.tdk-lambda.com/lp/legal.htm iJB Series Model Selector Model Input Voltage (V) Output Current (A) Output Voltage (V) Remote On/Off OCP/OVP Recovery 8 - 14 8 - 14 8 - 14 60 60 60 0.6 - 2.0 0.6 - 2.0 0.6 - 2.0 Negative Positive Negative Automatic Automatic Automatic iJB12060A006V-001-R (1) iJB12060A006V-002-R iJB12060A006V-003-R (1) Standard Transient Response. Preferred Model Outline Drawing Pinout PIN Function 1 +V Input 2 +V Input 3 Power Ground (0V) 4 Power Ground (0V) 5 Signal Ground (0V) 6 Not Connected 7 Output Trim 8 PMBus Address 9 Not Connected 10 Set Parallel Operation (PSET) 11 + Remote Sense 12 - Remote Sense 13 Power Ground (0V) 14 +V Output Top View Side View PIN 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Function +V Output +V Output +V Output Power Ground (0V) PMBus Clock PMBus Data PMBus Alarm Remote On/Off Fault Mgmt Power Good Current Share Synchronize Power Ground (0V) Power Ground (0V) Evaluation Board Evaluation kit part # Contents iJB60A-003-EVKIT-S1 Evaluation board with one piece of iJB12060A006V-003-R PMBus Dongle Board & USB cable CD ROM User manual available at iJx series technical file in our website Bottom View Other Industrial Products Typical Application Circuit CC-E 1.5 - 30W 5, 12, 24 or 48V input isolated DC-DC converters PX 10 - 60W 12, 24 or 48V input isolated DC-DC converters iAF, iBF, iCF, iCG 3 - 20A DOSA2 non isolated DC-DC converters iJB Series Digital POL Vin EN TRIM ADDR PSET SGND Vout Sense(+) GND Sense(-) 1-800-526-2324 • www.us.tdk-lambda.com/lp/ Load CPU,FPGA,ASIC INPUT Supply Bus Converter HOST Controller MCU,FPGA FAULT SYNC SHARE SDAT SCLK SALT PGOOD iQE, iQL, iQG 96 - 400W Quarter bricks iEH 300W Eighth brick For Additional Information, please visit us.tdk-lambda.com/lp/products/ijb-series.htm 215 Revision A8: Feb 2017