Il38121

   EMBED


Share

Transcript

.c om Instructions for Type SVS Indoor or Outdoor Autovalve®Lightning Arresters for Service from 0-10,000 Feet GENERAL different arresters used for overvoltage protection power apparatus such as oil insulated transformers and circuit breakers. 240 KV. a possible arrester unit and a difference in mounting leaflet are not interchangeable with other station arresters. In all cases an arrester rating, before consult the nearest Westinghouse district office. as of this series can be a single, unbraced structure. The arrester ratings up to 1 32 KV are of unit Those construction. an ratings casting identifies and gives the rating of that arrester arrester pole. rated unit only, not the complete Necessary mounting hard­ ware is in a bag in the shipping crate. tM arrester single of The unit nameplate attached to the base The distinguishing feature of the SVS series is its short compact design. All erected Because dimensions, the SVS units described in this changing The SVS arresters are rated from 36 to rating. difference in voltage distribution over the ua ls The SVS Autovalve lightning arresters as described in the following pages are station of I.L. 38-121-2 Nameplate and Ground Terminal Brackets These the ar from 132 KV to 240 KV are combination of two units. angle brackets are mounted under bottom of the arrester pole. A special feature of the SVS arrester is the pressure relief scheme which functions DESCRIPTION arrester consists porcelain ments. in of one or more clad units and required attach­ These units may be used singly or multiples up to a maximum arrester tri Each ca lP to vent the arrester if an internal failure occurs. rating of 240 KV as shown in Figure 1. lec Ratings The master nameplate gives the voltage rating of the arrester. This is the maximum .E sixty cycle rms voltage that may be applied across the arrester between the line and ground terminals. If this rating is exceeded the arrester is likely to remain conducting after discharging a surge and will be dam­ aged. w Changing Ratings The arrester voltage rating may be changed ww in the field by: ing the (1) increasing or decreas­ number of units in a pole and (2) changing arrester units with those of a Effective November, 1969 Supersedes I.L. 38-120-40, August, 1968 120 Kv SVS Autov alv e Arrest er Unit One bracket mounts the ground terminal and the INSTALLATION other the master nameplate. .c om 2 To give the highest degree of protection the arresters should be located near the ap­ Master Nameplate paratus to be protected, using leads of the shortest possible length. for all arresters with metal end castings, pole should be connected to a low resistance but not with the porcelain top arresters, where it is permanently mounted on the apparatus. The master nameplate iden­ tifies by style number the arrester pole, voltage rating, location of individual units and the position of the grading ring. A with preferably suitable should See be provided. surface Figure Used with arresters rated 144 to 240 KV as shown in Figure 1. dimensions. Non-Standard Arrester Parts a in It is important that for arresters be flat. 1 for clearance and arrester Line connections should be made in such manner that tM Insulating base - for use with discharge counter. as the accordance no excessive mechanical strain is placed on the arrester. (Furnished if requested) 1. foundation one the outline drawing for the arrester mounting Grading Ring Assembly the same an base casting. ground, Each arrester ua ls A separate master nameplate is provided The safe cantilever strength of the SVS arrester is 20,000 ft lbs and should not be exceeded by ar any combination of forces such as conductor side pull, wind or earthquake loading. RECEIVING, HANDLING, STORING lP Insulating Base Each unit is shipped in a wooden crate, and must be kept upright at all times. The packing slip is located on one of the crate Unpack carefully and examine for or other the porcelain. ca sides. breakage damage, especially to If damage exists, save the tri container and packing material and notify the carrier. Shortages should be checked with the carrier, or if not the fault of the carrier, with our nearest sales office. If parts do not agree with the packing list, the nearest Westinghouse repre­ lec contact sentative, giving him the necessary infor­ mation. The chart indicates the number of parts to look for when unpacking any one .E arrester of a given rating. Parts Required Rating 36 to 120 KV Inclusive 144 to ww it is installed first, and the ar­ If installed and not used with recording or measuring equip­ ment a cable shunt is supplied to bypass the unit. The bottom arrester unit is bolted di­ rectly to the foundation or the insulating base. At the same time insert the ground terminal and nameplate brackets between the foundation (or insulating base) and bottom end casting of the arrester unit. For multi-unit poles, once the bottom unit is firmly anchored, install the remaining unit as indicated on the master nameplate and in the outline drawing. When all units are bolted in place, add the line terminal and cover assembly to the top unit. and cover assembly, one set of ground grading ring is required, add the ring first terminal and nameplate brackets If a and then the terminal and cover assembly. Two arrester units, one line terminal and cover assembly, one set of ground terminal and nameplate brackets 2 40 KV Inclusive used, resters bolted to it. One arrester unit, one I ine terminal w 132 KV If INSTALLATION PRECAUTIONS Two arrester units, one line terminal and cover assembly, one set of ground terminal and nameplate brackets and grading ring Arrester exhaust ports should be di­ rected away from the transformer and other arrester poles. .c om 3 The line terminal assembly must not be used to lift the arrester. When installing arrester, all mounting feet must be flush before tightening bolts. Shim if necessary. Terminals arrester pole units should not be climbed for maintenance or any other All purpose. aluminum. \ alternate positions of line terminal compatible with copper or aluminum conductor .255 to .681 diameter mounting holes for .625 bolts _[1 \ r �Q I 20 ch� H� + in � �)' - 0- an 14.125 14 terminals are suitable for copper or -D-j *arrester should be mounted with the exhaust ports directed away from the ar transformers and other arrester poles Kv STYLE ' COMPLETE RAT lNG ARRESTER 60 71 90 96 631AO I 9AO I � = ca �I �I f-19 625 --jT = � = = = � � = � = = � = = = = = = � = � � � = = = � = � = � = � � � = = = = ! = "' "' "' "' "' "' "' "' "' = = � = 01mens1ons 1n Inches (Approxrmate) See Note X = = = = .::: = = � � = � � = = � � � = "'� z � c = c � � � c = = = c c = - c 0 � � z c � = � = = = z � � 0 c c � � = � = �- = � 0 c c� � � � � - z � � 34 NR 13 35 41 NR 26 38 631A011AO I 41 NR 30 42 6311012AOI 53 NR 35 47 6321648AOI 67 NR 41 52 632A023AO I 67 43 47 54 631A01010 I 6311014AO I 67 NR NR 110 631A01510I 67 NR 51 63 132 632A437AOI 90 NR 56 67 144 632A438AOI I02 20 65 90 98 114 .E I 08 168 631A439AOI I 04 20 73 180 631A440AOI I04 10 192 6321468AO I 116 25 77 95 631A511AOI 130 15 Ill w ww � .125 � _1_ 240 Kv 132 Kv lec 48 � tri 36-120Kv alternate positions of ground terminal ( with nameplate opposite) compatible with copper 2.2 or aluminum conductor r .204 to .530 diameter lP �� � insulating base unitS# 366C421G01-when used increase dimension '�A" by 14 inches. tM minimum distance between arrester phase legs. 36 ua ls The 240 Note X: Increased clearances are re�u1red over 6000 feet. Add 3% to drmensrons (C) and (0) for each 1000 feet above 6000 feet Fig. Out line Dimensions for 36-240 Kv SVS Lightning Arrester 59 128 134 .c om 4 Line Terminal Cable Size: 100 milliamps and the current should not #2 to 350 MCM copper flow for more than 5 seconds. The voltage should be run up to sparkover quickly so as #4 to 350 MCM aluminum not to overheat the gap grading resistors. #4 to 300 MCM ACSR The series gaps are shunted by a high a diameter of .255 to .681 inches. resistance, giving a current flow of 0. 5 to 1. 0 ua ls The terminal will accept conductors with milliamperes grading energized at rated voltage. Ground Terminal when measure grading current or watts-loss will give readings Cable Size: current Tests made to insulators. #4 to 4/0 MCM aluminum infinite resistance. A megger test will not show an #6 to 3/0 MCM ACSR are high compared to that #4 to 200 MCM copper It may be found that Doble or megger The terminal will accept conductors with a diameter of .204 to .530 inches. tests on units of the same rating will give If one unit shows con­ different readings. siderable deviation from the rest, its con­ Testing A ll arrester units are tested at the factory. Each element is surge tested, the valve to make periodic readings tested to insure it is tightly sealed against and note the Contamination on trends of the readings. the porcelain surface may cause faulty or ar complete arrester unit is tested for 60 cycle sparkover, radio influence and pressure tM dition should be questioned and the nearest sales office contacted. It is more significant misleading readings. Units should be tested clean and dry. Units should not be opened in moisture. MAINTENANCE leading to the possibility of moisture en­ trance and consequent deterioration of the arresters. No simple field tests will check tenance other than occasional inspection. ca lP the field as to do so, would break the seal, The SVS arrester requires no regular main­ In locations where the porcelain becomes contaminated by dirt, soot, salt, etc., it is ratory equipment. recommended that the arresters be cleaned periodically. If an tri the complete characteristics of an arrester unit, since this requires considerable labo­ arrester is suspected of having CAUTION only lec been damaged in service, the only field tests that should be attempted are 60 cycle sparkover, Doble, or megger tests, then on clean dry arresters. IT IS NOT RECOMMENDED THAT ARRESTERS CONSISTING OF MORE It must be THAN understood that such tests will not deter­ mine the condition of the valve elements. TWO UNITS BE WASHED WHILE THEY ARE ENERGIZED. For more information refer to NEMA Bul­ .E letin #70; Guide for Field Testing of Light­ CORRESPONDENCE ning Arresters. If 60 cycle sparkover tests are made, the circuit should limiting maximum a Direct any inquires pertaining to the light­ means for ning arrester to the nearest Westinghouse current sales office giving all information stated on possible the arrester (after sparkover) to w through the provide the master nameplate. ww Westinghouse Electric Corporation Distribution Apparatus Division, Bloomington, Indiana 47401 Printed io U.S.A. .c om Instructions for Type SVS Indoor or Outdoor Autovalve®Lightning Arresters for Service from 0-10,000 Feet different rating. The SVS Autovalve lightning arresters as described in the following pages are station arresters used for overvoltage protection power apparatus such as oil insulated transformers and circuit breakers. 240 KV. arrester unit and a difference in mounting leaflet are not interchangeable with other station arresters. an In arrester all cases rating, before consult the nearest Westinghouse district office. distinguishing is arrester feature of the SVS its short compact design. ratings of All this series can be single unit Those construction. casting identifies and gives the rating of that arrester rated unit only, not the complete arrester pole. Necessary mounting hard­ ware is in a bag in the shipping crate. tM erected as a single, unbraced structure. The arrester ratings up to 132 KV are of an The unit nameplate attached to the base The series of a possible dimensions, the SVS units described in this changing The SVS arresters are rated from 36 to Because difference in voltage distribution over the ua ls GENERAL of I.L 38-121-2 Nameplate and Ground Terminal Brackets These the ar from 132 KV to 240 KV are combination of two units. angle bottom brackets are mounted under of the arrester pole. A special feature of the SVS arrester is the pressure relief scheme which functions lP to vent the arrester if an internal failure DESCRIPTION Each arrester porcelain consists of one or more clad units and required attach­ These units may be used singly or multiples up to a maximum arrester tri ments. in ca occurs. rating of 240 KV as shown in Figure 1. lec Ratings The master nameplate gives the voltage rating of the arrester. This is the maximum sixty cycle rms voltage that may be applied the arrester between the line and .E across ground terminals. If this rating is exceeded the arrester is likely to remain conducting after discharging a surge and will be dam­ aged. w Changing Ratings The arrester voltage rating may be changed ww in the field by: ing the (1) increasing or decreas­ number of units in a pole and (2) changing arrester units with those of a Effective November, 1969 Supersedes l.L. 38-120-40, August, 1968 120 Kv SVS Aut ov alv e Arr ester Unit One bracket mounts the ground terminal and the INSTALLATION other the master nameplate. .c om 2 To give the highest degree of protection the arresters should be located near the ap­ Master Nameplate paratus to be protected, using leads of the shortest for all arresters with metal end castings, pole should be connected to a low resistance not with the porcelain top arresters, where it is permanently mounted on the base casting. The master nameplate iden­ tifies by style number the arrester pole, voltage rating, location of individual units and the position of the grading ring. ground, A suitable should See Used with arresters rated 144 to 240 KV as Each arrester the same foundation one in as the accordance the outline drawing for the arrester be provided. mounting Grading Ring Assembly surface It is important that for Figure arresters be flat. 1 for clearance and arrester dimensions. shown in Figure 1. Line connections should be made in such manner that tM a Non-Standard Arrester Parts no excessive mechanical strain is placed on the arrester. (Furnished if requested) 1. preferably apparatus. with length. an but possible ua ls A separate master nameplate is provided Insulating base - for use with discharge counter. The safe cantilever strength of the SVS arrester is 20,000 ft lbs and should not be exceeded by ar any combination of forces such as conductor side pull, wind or earthquake loading. RECEIVING, HANDLING, STORING lP Insulating Base Each unit is shipped in a wooden crate, and must be kept upright at all times. The packing slip is located on one of the crate Unpack carefully and examine for or other the porcelain. ca sides. breakage damage, especially to If damage exists, save the tri container and packing material and notify the carrier. Shortages should be checked with the carrier, or if not the fault of the carrier, with our nearest sales office. If parts do not agree with the packing list, If used, resters it is installed first, and the ar­ bolted to it. If installed and not used with recording or measuring equip­ ment a cable shunt is supplied to bypass the unit. The bottom arrester unit is bolted di­ rectly to the foundation or the insulating base. At the same time insert the ground sentative, giving him the necessary infor­ mation. The chart indicates the number of For multi-unit poles, once the bottom unit contact the lec Westinghouse repre­ terminal and nameplate brackets between the foundation (or insulating base) and nearest parts to look for when unpacking any one .E arrester of a given rating. Parts Required Rating 36 to 120 KV Inclusive ww 144 to casting of the arrester unit. firmly anchored, install the remaining unit as indicated on the master nameplate and in the outline drawing. When all units are bolted in place, add the line terminal If a One arrester unit, one line terminal and cover assembly to the top unit. grading ring is required, add the ring first terminal and nameplate brackets and then the terminal and cover assembly. Two arrester units, one line terminal and cover assembly, one set of ground terminal and nameplate brackets 2 40 KV Inclusive is end and cover assembly, one set of ground w 132 KV bottom INSTALLATION PRECAUTIONS Two arrester units, one line terminal and cover assembly, one set of ground terminal and nameplate brackets and grading ring Arrester exhaust ports should be di­ rected away from the transformer and other arrester poles. .c om 3 The line terminal assembly must not be When installing arrester, all mounting feet must be flush before tightening bolts. used to lift the arrester. Shim if necessary. Terminals arrester pole units should not be All for maintenance or any other aluminum. \ mounting holes for alternate positions of line terminal compatible with copper or aluminum conductor to diameter .625 bolts .255 20inchrw " �!'='i A \4) �o-+-o--, 14.125 l � • r- .681 . ,', �) . &) t-c--.: alternate positions of ground terminal (with nameplate opposite) compatible with copper or aluminum conductor to diameter � .204 36-120Kv Kv COMPLETE ARRESTER 90 ca � ;;;: = = � � � = = = � = � = � = � � � = = �� = � = � = = � � = � = � = IDB � = = � � � = <0 � � = = = - .:= = = � � "" = � = � "" ""� "" � � "" � = - � � "" "- � "" 0 � � � � � u � �- � � = � � � � 632AO I 910I 34 NR 23 35 632102010 I 41 NR 26 38 � ""� � � ""� = � = � 632A021 10I 41 NR 30 42 53 NR 35 47 632164810I 67 NR 41 52 632AD231DI 67 NR 43 54 67 NR 47 59 NR 52 63 56 65 67 98 114 6321024AD I 67 6321437ADI 90 NR 632A43BADI ID2 2D 168 6321439ADI ID4 2D 73 IBD 632A44DADI ID4 2D 632146BIDI 116 25 77 95 6321521ADI I3D 25 Ill w Note X: � � � "- 632A021101 6321D251D I 24D = - � 132 192 � = � � � � "- = 12D 144 ww 01 mens 1 ons In Inches (ApproXImate) See Note X = .E 96 = � = = = � lec 72 � tri • �I .530 � .125 2.2� __j__ 'f--19.625 --jT 240 Kv 132 Kv RAT lNG 60 lP �� 48 insulating base unitS# 366C421G01-when used increase dimension "A" by 14 inches. ar 'arrester should be mounted with the exhaust ports directed away from the transformers and other arrester poles STYLE _______ _ _ _____J �� � tM minimum distance between arrester phase legs. 36 terminals are suitable for copper or ua ls climbed purpose. an The Increased c learances are requr red over 6DDD feet. ldd 3% to dimensrons (C) and (D) for each IDDD feet above 6DDD teet. Fig. 1 Out I ine Dimensions for 36-240 Kv SVS Lightning Arrester 9D 128 134 .c om 4 Line Terminal 100 milliamps and the current should not flow for more than 5 seconds. The voltage Cable Size: #2 to 350 MCM copper should be run up to sparkover quickly so as #4 to 350 MCM aluminum not to overheat the gap grading resistors. #4 to 300 MCM ACSR The series gaps are shunted by a high a diameter of . 255 to .681 inches. resistance, giving a current flow of 0. 5 to 1. 0 ua ls The terminal will accept conductors with grading current when energized at rated voltage. milliamperes Tests made to Ground Terminal measure grading current or watts-loss will Cable Size: #4 to 200 MCM copper insulators. #4 to 4/0 MCM aluminum infinite resistance. give readings that an #6 to 3/0 MCM ACSR are high compared to A megger test will not show It may be found that Doble or megger The terminal will accept conductors with a diameter of .204 to .530 inches. tests on units of the same rating will give If one unit shows con­ different readings. Testing tM siderable deviation from the rest, its con­ dition should be questioned and the nearest sales office contacted. It is more significant A ll arrester units are tested at the factory. Each valve element is surge tested, the radio influence and pressure tested to insure it is tightly sealed against periodic readings and note the Contamination on the porcelain surface may cause faulty or misleading readings. Units should be tested clean and dry. Units should not be opened in lP moisture. make trends of the readings. ar complete arrester unit is tested for 60 cycle sparkover, to the field as to do so, would break the seal, MAINTENANCE leading to the possibility of moisture en­ trance and consequent deterioration of the The SVS arrester requires no regular main­ arresters. tenance other than occasional inspection. ca No simple field tests will check In locations where the porcelain becomes unit, since this requires considerable labo­ contaminated by dirt, soot, salt, etc., it is ratory equipment. recommended that the arresters be cleaned periodically. If been an tri the complete characteristics of an arrester arrester is suspected of having damaged in service, the only field CAUTION IT only It must be ARRESTERS CONSISTING O F MORE understood that such tests will not deter­ THAN TWO UNITS BE WASHED WHILE THEY ARE ENERGIZED. lec tests that should be attempted are 60 cycle sparkover, Doble, or megger tests, then on clean dry arresters. mine the condition of the valve elements. IS NOT RECOMMENDED THAT For more information refer to NEMA Bul­ .E letin #70; Guide for Field Testing of Light­ CORRESPONDENCE ning Arresters. If 60 cycle sparkover tests are made, the circuit should limiting maximum ning arrester to the nearest Westinghouse possible current sales office giving all information stated on ww a means the arrester (after sparkover) to w through the Direct any inquires pertaining to the light­ for provide the master nameplate. Westinghouse Electric Corporation Distribution Apparatus Division, Bloomington, Indiana 47401 Printed in U.S.A.