Transcript
Ethernet Media Converters and Extenders
IMC-101G Series Industrial gigabit Ethernet-to-fiber media converter
››10/100/1000BaseT(X) and 1000BaseSFP slot supported ››Link Fault Pass-through (LFP) ››Power failure, port break alarm by relay output ››Redundant power input ››-40 to 75°C operating temperature range (T models) ››Designed for hazardous locations (Class 1 Div. 2/Zone 2, IECEx) ››More than 20 options available* *See the SFP-1G Series datasheet for details.
Introduction The IMC-101G industrial gigabit modular media converters are designed to provide reliable and stable 10/100/1000BaseT(X) to 1000BaseSX/LX/LHX/ZX media conversion in harsh industrial environments. The IMC-101G’s industrial design is excellent for keeping your industrial automation applications running continuously,
and each IMC-101G converter comes with a relay output warning alarm to help prevent damage and loss. All IMC-101G models are subjected to a 100% burn-in test, and are available in models that support a standard operating temperature range of 0 to 60°C, and an extended operating temperature range of -40 to 75°C.
Specifications Technology
Standards: IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) and 100BaseFX IEEE 802.3ab for 1000BaseT(X) IEEE 802.3z for 1000BaseSX/LSX/LX/LH/LHX/ZX/E2X
Interface
RJ45 Ports: 10/100/1000BaseT(X) Fiber Ports: 1000BaseSFP slot LED Indicators: PWR1, PWR2, FAULT, 10/100M (TP port), 1000M (TP and Fiber port) DIP Switches: Port break alarm mask, Link Fault Pass-through, SFP Auto/Force Alarm Contact: One relay output with current carrying capacity of 1 A @ 24 VDC
Physical Characteristics
Housing: Metal, IP30 protection Dimensions: 53.6 x 135 x 105 mm (2.11 x 5.32 x 4.13 in) Weight: 630 g (1.39 lb) Installation: DIN-rail mounting, wall mounting (with optional kit)
Environmental Limits
Operating Temperature: Standard Models: 0 to 60°C (32 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) Storage Temperature: -40 to 85°C (-40 to 185°F) Ambient Relative Humidity: 5 to 95% (non-condensing)
Overload Current Protection: 2.5 A Reverse Polarity Protection: Present
Standards and Certifications
Safety: UL 508 Hazardous Location: UL/cUL Class I Division 2 Groups A/B/C/D, ATEX Zone 2 Ex nC nL IIC T4, IECEx EMC: EN 55032/24 EMI: CISPR 32, FCC Part 15B Class A EMS: EN 61000-4-2 (ESD): Contact: 6 kV; Air: 8 kV EN 61000-4-3 (RS): 80 MHz to 1 GHz: 3 V/m EN 61000-4-4 (EFT): Power: 2 kV; Signal: 2 kV EN 61000-4-5 (Surge): Power: 1 kV; Signal: 1 kV EN 61000-4-6 (CS): 150 kHz to 80 MHz: 3 V/m EN 61000-4-8 (PFMF) EN 61000-4-11 Green Product: RoHS, CRoHS, WEEE Shock: IEC 60068-2-27 Freefall: IEC 60068-2-32 Vibration: IEC 60068-2-6
MTBF (mean time between failures) Time: 500,540 hrs Standard: Telcordia (Bellcore), GB
Warranty
Warranty Period: 5 years Details: See www.moxa.com/warranty
Power Requirements
Input Voltage: 12 to 45 VDC redundant inputs Input Current: 220 mA @ 45 VDC max. Connection: Removable terminal block
1
w w w. m o x a . c o m
Ethernet Media Converters and Extenders
Dimensions Unit: mm (inch)
25.4 (1)
Ø6 (0.24)
Ø6 (0.24) 13.9 (0.55) 18.2 (0.72) 13.9 (0.55)
25.71 (1.01)
10 (0.39) 10 (0.39) 44 (1.73)
13 (0.51) 18 (0.71) 13 (0.51)
46.77 (1.84)
27.2 (1.07)
48.3 (1.90)
135 (5.32)
39.37 (1.55)
5 ( 0.20)
66.8 (2.63)
13.1 (0.52) 9.5 (0.37)
Ø3.5 (0.14) 57.05 (2.25)
54 (2.13)
30 (1.18)
46 (1.81)
15.1 (0.59)
7.75 (0.31)
30.5 (1.2)
7.75 (0.31)
23.15 (0.91) 10.65 30.5 (1.20) 10.65 (0.42) (0.42)
Side View
Front View
Rear View
Panel-Mounting Kit
Ordering Information Available Models
IMC-101G: Industrial 10/100/1000BaseT(X) to 1000BaseSFP media converter, 0 to 60°C operating temperature IMC-101G-T: Industrial 10/100/1000BaseT(X) to 1000BaseSFP media converter, -40 to 75°C operating temperature
Package Checklist • 1 IMC-101G media converter • Quick installation guide (printed) • Warranty card
Note: You must purchase at least one SFP-1G module to use these products. See the SFP-1G Series datasheet for details.
IECEx Models
IMC-101G-IEX: Industrial 10/100/1000BaseT(X) to 1000BaseSFP media converter, IECEx, 0 to 60°C operating temperature IMC-101G-T-IEX: Industrial 10/100/1000BaseT(X) to 1000BaseSFP media converter, IECEx, -40 to 75°C operating temperature
Optional Accessories (can be purchased separately)
DR-4524: 45W/2A DIN-rail 24 VDC power supply, 85 to 264 VAC input DR-75-24: 75W/3.2A DIN-rail 24 VDC power supply, 85 to 264 VAC input DR-120-24: 120W/5A DIN-rail 24 VDC power supply, 88 to 132 VAC or 176 to 264 VAC input by switch WK-46: DIN-rail/wall-mounting kit, 2 plates with 4 screws RK-4U: 4U-high 19-inch rack-mounting kit
2
w w w. m o x a . c o m
Ethernet Media Converters and Extenders
SFP-1G Series 1-port Gigabit Ethernet SFP modules
››Digital Diagnostic Monitor Function ››-40 to 85°C operating temperature range (T models) ››IEEE 802.3z compliant ››Differential LVPECL inputs and outputs ››TTL signal detect indicator ››Hot pluggable LC duplex connector ››Class 1 laser product, complies with EN 60825-1 EN : 60825
Specifications Interface
Ethernet Ports: 1 Connectors: Duplex LC Connector or Simplex LC Connector (WDM-type only)
Optical Fiber SFP-SX Multi-Mode OM1 OM2 300 m 550 m 850
Gigabit Ethernet SFP SFP-LX SFP-LH SFP-LHX Single-Mode Single-Mode Single-Mode G.652 G.652 G.652 10 km 30 km 40 km 1310 1310 1310
SFP-ZX SFP-EZX SFP-EZX-120 Transceiver Type Single-Mode Single-Mode Single-Mode Fiber Cable Type G.652 G.652 G.652 Typical Distance 80 km 110 km 120 km Typical (nm) 1550 1550 1550 TX Range Wave830 to 860 1270 to 1355 1280 to 1355 1280 to 1355 1280 to 1340 1530 to 1570 1530 to 1570 1530 to 1570 (nm) length RX Range 770 to 860 1260 to 1610 1260 to 1610 1260 to 1610 1260 to 1610 1260 to 1610 1260 to 1610 1100 to 1600 (nm) TX Range -4 to -9.5 -1 to -9 -3 to -9 -3 to -8 +3 to -4 +5 to 0 +5 to 0 +3 to -2 (dBm) RX Range 0 to -18 -1 to -19 -3 to -21 -3 to -23 -1 to -24 -1 to -24 -9 to -30 -8 to -33 (dBm) Optical Power Link Budget 8.5 10 12 15 20 24 30 31 (dB) Dispersion 4.3 3.6 5 5 1 1 1 1 1 2 Penalty (dB) Note: When connecting the SFP-LHX, ZX, EZX, or EZX-120, we recommened using an attenuator to prevent the transceiver from being damaged by excessive optical power. SFP-10A
SFP-LSX Multi-Mode OM2 OM1 1 km 2 km 1310
SFP-10B
WDM Gigabit Ethernet SFP SFP-20A SFP-20B Single-Mode G.652 20 km TX 1310, RX 1550 TX 1550, RX 1310
SFP-40A SFP-40B Transceiver Type Single-Mode Single-Mode Fiber Cable Type G.652 G.652 Typical Distance 10 km 40 km Typical (nm) TX 1310, RX 1550 TX 1550, RX 1310 TX 1310, RX 1550 TX 1550, RX 1310 TX Range Wave1270 to 1355 1530 to 1570 1270 to 1355 1530 to 1570 1290 to 1330 1530 to 1570 (nm) length RX Range 1480 to 1580 1260 to 1360 1480 to 1580 1260 to 1360 1480 to 1580 1260 to 1360 (nm) TX Range -3 to -9 -2 to -8 +2 to -3 (dBm) RX Range -3 to -21 -2 to -23 -1 to -23 (dBm) Optical Power Link Budget 12 15 20 (dB) Dispersion 2 3 1 Penalty (dB) Note: WDM-type SFP modules must be used in pairs (e.g., SFP-1G10ALC and SFP-1G10BLC) Note: When connecting the SFP-40A and 40B, we recommend using an attenuator to prevent damage caused by excessive optical power.
Typical Distance: To reach the typical distance of specified fiber transceiver, please refer to formula: Link budget(dB) > dispersion penalty(dB) + total link loss(dB).
3
w w w. m o x a . c o m
Ethernet Media Converters and Extenders
Power Requirements
Warranty
Power Consumption: Max. 1 W
Warranty Period: 5 years Details: See www.moxa.com/warranty
Environmental Limits
Operating Temperature: Standard Models: 0 to 60°C (32 to 140°F) Wide Temp. Models: -40 to 85°C (-40 to 185°F) Storage Temperature: -40 to 85°C (-40 to 185°F) Ambient Relative Humidity: 5 to 95% (non-condensing)
Standards and Certifications
Safety: CE, FCC, TÜV (EN 60825), UL 60950-1 Marine: DNV, GL
Dimensions Unit: mm (inch)
SFP-1G Series
SFP-1G Series (WDM Type) 13.4 (0.5)
13.4 (0.5)
Top View
Top View
55.5 (2.2)
6.3 (0.2)
56.6 (2.2)
13.4 (0.5)
11.28 (0.4)
55.5 (2.2)
8.15 (0.3) 8.4 (0.3)
13.4 (0.5)
8.2 (0.3) 8.4 (0.3)
45.0 (1.8)
2.6 (0.1)
8.0 (0.3)
Rear View
Rear View
13.7 (0.5) 14.0 (0.6)
Side View
13.7 (0.5)
14.0 (0.6)
Side View
Ordering Information Gigabit Ethernet SFP Models Standard Temperature
Wide Temperature
Models (0 to 60˚C)
Models (-40 to 85˚C)
Transeiver Type
WDM Gigabit Ethernet SFP Models Typical Distance
Wide
Standard Temperature (0 to 60˚C)
Temperature
Transeiver Type
Typical Distance
(-40 to 85˚C)
SFP-1GSXLC
SFP-1GSXLC-T*
Multi-Mode
300/550 m
SFP-1G10ALC
SFP-1G10ALC-T
Single-Mode
10 km
SFP-1GLSXLC
SFP-1GLSXLC-T
Multi-Mode
1/2 km
SFP-1G10BLC
SFP-1G10BLC-T
Single-Mode
10 km
SFP-1GLXLC
SFP-1GLXLC-T
Single-Mode
10 km
SFP-1G20ALC
SFP-1G20ALC-T
Single-Mode
20 km
SFP-1GLHLC
SFP-1GLHLC-T
Single-Mode
30 km
SFP-1G20BLC
SFP-1G20BLC-T
Single-Mode
20 km
SFP-1GLHXLC
SFP-1GLHXLC-T
Single-Mode
40 km
SFP-1G40ALC
SFP-1G40ALC-T
Single-Mode
40 km
SFP-1GZXLC
SFP-1GZXLC-T
Single-Mode
80 km
SFP-1G40BLC
SFP-1G40BLC-T
Single-Mode
40 km
SFP-1GEZXLC
–
Single-Mode
110 km
–
–
–
–
SFP-1GEZXLC-120
–
Single-Mode
120 km
–
–
–
–
*SFP-1GSXLC-T: -20 to 75˚C operating temperature
Package Checklist • SFP-1G module • Warranty card
4
© Moxa Inc. All rights reserved. Updated Feb. 8, 2017. Specifications subject to change without notice. Please visit our website for the most up-to-date product information.