Preview only show first 10 pages with watermark. For full document please download

Imod Industrial Module System

   EMBED


Share

Transcript

IMod Industrial Module System Industrial Module system is an innovative complete fiber optic cabling solution which is modular, reliable and sturdy and is designed for industrial use. It is particularly recommended for industries which generate, transport and distribute power, the Oil and Gas industry, video surveillance and security, and any other industrial automation. The system is made up of a Patch Panel which can hold up to 12 connectors(24 SFF)in the standard version, 6 connectors(12 SFF) in the Mini version, and a series of factory-terminated cables according to client specifications at the time of ordering. OPTICAL CONNECTIVITY + FIBER MANAGEMENT SYSTEM PATCH PANEL IMod - Industrial Module System IMod and Mini-IMod are compact, sturdy panels, designed for managing the termination and/or splicing of fiber optic cable, mountable on a 35mm DIN Rail. The 30 degree slope of the connections allows for reduced installation depth; the DIN Rail clip can also be fixed to the sides of the panels. The cable-entry kits, produced according to typology of cable, guarantee an efficient management of the fibers. IMod and Mini-IMod are available with pre-installed adapters and pigtails ready for fusion-splicing, or just with adapters to house the pre-terminated cables, or otherwise in the splice-through version. Characteristics Compact and sturdy module for DIN rail DIN Rail clip fixable to the sides Up to 12 fibers (24 SFF) Up to 6 fibers in the Mini version (12 SFF) Reduced installation depth Available preloaded with pigtails Available in splice through version OPTICAL CONNECTIVITY + FIBER MANAGEMENT SYSTEM IMod - Industrial Module System PATCH PANEL Specifications Material: Anodized aluminium IMod weight: 300 gr empty Mini-IMod weight: 200 gr empty A B C D S IMod mm 170 135 175 200 40 Mini-IMod mm 150 115 110 135 40 Accessories A B D E C OPTICAL CONNECTIVITY + FIBER MANAGEMENT SYSTEM IMod - Industrial Module System ORDERING CODE INDUSTRIAL MODULE I M o d - A A - B B - C C - D - A A - B B - C C MINI-INDUSTRIAL MODULE M - I A A Select fiber type or adapter type B 9 6 5 O O S M S S S S S M M M P = = = = = = = = 2 0 = ST 3 0 = FC 4 0 = SC 5 8 = LC Duplex B B = For a complete list please see jumper cable code C C M o d 9/125 OS2 semitight yellow 62,5/125 OM1 semitight blue 50/125 OM2 semitight orange 50/125 OM3 semitight aqua 50/125 OM4 semitight aqua No pigtails only adapter zirconia sleeve No pigtails only adapter phosphor-bronze sleeve Splice Through no adapter Select number of pigtails or adapters 0 2 = 0 4 = 0 6 = ... ... = 1 2 = ... ... = 2 4 = 2 pigtails or adapter 4 pigtails or adapter 6 pigtails or adapter ….. pigtails or adapter 12 pigtails or adapter ….. pigtails or adapter 24 pigtails or adapter B D A B C D E - D Select connectivity type Select cable entry type = = = = = Bracket, 1 m miniflex tube with 2 gripper saddle Bracket with cable ties Bracket with cable glande PG 13,5 Bracket for Imod Line System with 2 gripper saddle Bracket for IMod Line System mounting nut PG 16 Features and specifications subject to change without prior notification. OPTICAL CONNECTIVITY + FIBER MANAGEMENT SYSTEM IMod Line System IMod Line system is a cabling platform entirely factoryassembled according to client specifications and ready to use: the connectorised ends of the cable, which are protected by a metal tube during the laying, fit exactly into the Patch Panel IMod and Mini-IMod. The 5mm diameter corrugated tube, which connects the cable to the Patch Panel, allows the fibers to be installed safely and easily into the cabinets, as well as protecting the fibers from a tight radius of curvature; the length can be decided by the client. IMod Line system can be made with a cable which either has dielectric armour and a LSZH jacket or corrugated steel armour and PE jacket. Installation is quick and easy: there is no need for specialized staff or expensive equipment, therefore installation time and costs are significantly reduced. This product is shipped in adequate packaging and includes the test report. OPTICAL CONNECTIVITY + FIBER MANAGEMENT SYSTEM IMod Line System FEATURES Characteristics Ready to use system For internal and external applications Factory-assembled and tested Quick and easy installation Reduced installation time and cost Cable length and connectors defined by the client FANOUT LEG FIBER COUNT 4 6 8 10 12 IMod Shortest/longest length L2 - L2a [ mm ] 55/60 55/65 55/70 55/75 55/80 Mini-IMod Shortest/longest length L2 - L2a [ mm ] 41/44 41/47 - - - Shortest/longest length L1 - L1a [ mm ] Length H [ mm ] Tube length [ mm ] Single fanout leg diameter [ Ø mm ] Fanout leg jacket material 300 / fino a 2500 65 L1 + L2 + 100 1.6 ± 0.1 LSZH Low Smoke Zero Halogen CABLE TERMINATION Tube outer diameter [ Ø mm ] 30 ± 2 Maximum tensile strength [ N ] 1000 Crush resistance [ N ] 1000 Environmental protection class (with O-RING ) [ IP ] OPTICAL CONNECTIVITY + FIBER MANAGEMENT SYSTEM 67 IMod Line System ORDERING CODE I M L - A B C - D D E E F F G - H H H H A Select number fibers E E Select connector type side B 2 4 6 8 A B C D E F G H = = = = = = = = = = = = E 0 E 0 = = F F Select tube length L1/L1a B C D E F ... D N X C D E F ... F N X = = = = = = = = Select fiber type 9 5 6 O = = = = Single mode 9/125 OS1 50/125 OM2 62,5/125 OM1 50/125 OM3 G Fanout leg type L2/L2a M = 50/125 OM4 A B = = C Select cable design H H H A F = = 1 1 3 2 5 5 D 2 3 4 5 D 2 fiber 4 fiber 6 fiber 8 fiber 10 fiber 12 fiber 14 fiber 16 fiber 18 fiber 20 fiber 22 fiber 24 fiber D 0 0 0 8 D Glass armoured LSZH jacket, 1500 N Corrugated steel armoured PE Jacket, 1000 N Select connector type side A = ST = FC = SC = LCD = For a complete list please see jumper cable code Use option from item DD No connector L1 30cm L1a 30cm L1 40cm L1a 40cm L1 50cm L1a 50cm L1 60cm L1a 60cm L1 ….cm L1a ….cm L1 40cm L1a 60cm No Miniflex tube Specified in note Fit in IMod Fit in Mini-Imod H Select cable length in meters* 3 = 135 meter = 1253 meter * length tolerance including fanout leg Up to a 50 m: + / - 50 cm From 51 to 100 m: + / - 100 cm Over 101 m: + / - 2 % Features and specifications subject to change without prior notification. OPTICAL CONNECTIVITY + FIBER MANAGEMENT SYSTEM IMod Plug and Play I Mod Plug and Play is a cabling solution particularly suitable for linking racks in the same room or in the same building where the cable ducting system is ample: the connectors are already inserted inside the IMod and Mini-IMod panels and once fixed to the DIN rail they are ready to be connected to the equipment. A tube between the cable and the IMod allows for the safe and easy management of the fibers in the rack. The length of the tube can be defined by the client. I Mod Plug and Play can be made with a cable which either has dielectric armour and a LSZH jacket or corrugated steel armour and PE jacket. Installation is quick and easy: there is no need for specialized staff or expensive equipment, therefore significantly reducing installation time and costs. Characteristics Ready to use system For internal and external applications Factory-assembled and tested Quick and easy installation Reduced installation time and cost Cable length and connectors defined by the client OPTICAL CONNECTIVITY + FIBER MANAGEMENT SYSTEM IMod Plug and Play ORDERING CODE I M P - A B C - D D E E F F - G G G G A Select number fibers E E Select connector type side B 2 4 6 8 A B C D E F G H = = = = = = = = = = = = E 0 E 0 = = F F Select tube length L1/L2 C D E F ... D X C D E F ... F X = = = = = = = B Select fiber type 9 5 6 O = = = = Single mode 9/125 OS1 50/125 OM2 62,5/125 OM1 50/125 OM3 G G G M = 50/125 OM4 1 1 3 2 5 5 C Select cable design A F = = D 2 3 4 5 D 2 fiber 4 fiber 6 fiber 8 fiber 10 fiber 12 fiber 14 fiber 16 fiber 18 fiber 20 fiber 22 fiber 24 fiber D 0 0 0 8 D Use option from item DD No connector L1 30cm L2 30cm L1 40cm L2 40cm L1 50cm L2 50cm L1 60cm L2 60cm L1 ….cm L2 ….cm L1 40cm L2 60cm Specified in note G Select cable length in meters* 3 = 135 meter = 1253 meter Features and specifications subject to change without prior notification. Glass armoured LSZH jacket, 1500 N Corrugated steel armoured PE Jacket, 1000 N Select connector type side A = ST = FC = SC = LCD = For a complete list please see jumper cable code OPTICAL CONNECTIVITY + FIBER MANAGEMENT SYSTEM IMod - Industrial Module System Jacket material Weight Kg / Km Diameter mm Tensile strength [N] Crush resistant N Min. bending radius [mm] unloaded Temperature range installation [C°] Temperature range service [C°] Fire load MJ/km FEATURES - - - E1 E3 E11 F1 F1 - 2 - 16 fiber LSZH 55 7.5 1500 2000 60 -15 +40 - 30 +70 1300 18 - 24 fiber LSZH 60 8 1500 2000 60 -15 +40 -30 +70 1300 2 - 16 fiber PE 75 8.5 1000 2000 55 -40 +70 -40 +70 - 18 - 24 fiber PE 80 8.5 1000 2000 55 -40 +70 -40 +70 - IEC 60794-1-2 Method Glass armoured cable Steel armoured cable Air ring in cardboard box 50x50x30cm Cardboard reel-small Ø 75 x 19 cm Cardboard reel-small Ø 75 x 35 cm Wooden reel Ø from 60 cm Glass armoured cable U-DQ(ZN)BH 70 m 300 m 400 m 2000 m Corrugated steel armoured cable A-DQ(ZN)(SR)2Y 50 m 200 m 260 m 2000 m OPTICAL CONNECTIVITY + FIBER MANAGEMENT SYSTEM IMod - Industrial Module System CONNECTORS LC MU SC Compliance IEC 61754-20 IEC 61754-6 IEC 61754-4 Class assemblies 0.1dB / A / B 0.1dB / A / B 0.1dB / A / B Ferrule Ø 1.25 mm 1.25 mm 2.5 mm Cable Ø 0.9 - 3.0 mm 0.9 - 2.0 mm 0.9 - 3.0 mm Cable retention 70 N 70 N 100 N blue green beige / aqua / black brown green brown blue green beige / aqua / black Colour of housing / boot SM 0° PC SM 8° APC MM E2000 TM ST FC Compliance IEC 61754-15 IEC 61754-13 IEC 61754-13 Class assemblies 0.1dB / A / B B 0.1dB / A / B Ferrule Ø 2.5 mm 2.5 mm 2.5 mm Cable Ø 0.9 - 3.0 mm 0.9 - 3.0 mm 0.9 - 3.0 mm Cable retention 100 N 100 N 100 N blue green beige / aqua / black yellow black green black Colour of housing / boot SM 0° PC SM 8° APC MM Grade 0.1 dB single-mode Insertion loss* Return loss random mate nero Grade A single-mode Grade B single-mode std Grade M multi-mode std 0.06 dB mean 0.15 dB mean 0.50 dB mean 0.30 dB mean 0.15 dB >97% 0.30 dB >97% 0.25 dB >97% 0.20 dB max against ref. 0.15 dB max 0.30 dB max 0.35 dB max PC > 45 > 45 > 45 > 25 UPC > 50 > 50 > 50 - APC > 70 > 70 > 70 - EN 61300-3-34 EN 61300-3-4 Method B EN 61300-3-6 Method 1 * SM λ1300nm * MM * FOR THE PRODUCT CONFORMITY CONTROL: EN 61300-3-4 METHOD C ENCIRCLED FLUX LAUNCH CONDITION ON 50um FIBER AND 850nm IEC 61280-4-1 OPTICAL CONNECTIVITY + FIBER MANAGEMENT SYSTEM IMod - Industrial Module System FIBER FIBER CATEGORY ISO/IEC 11801 EN 50173 STANDARD AND NORMS OM1 OM2 Bend Insensitive OM3 Bend Insensitive OM4 Bend Insensitive IEC 60793-2-10 A.1b TIA/ EIA 492 AAA IEC 60793-2-10 A1a.1 TIA/EIA 492 AAAB IEC 60793-2-10 A1a.2 TIA/EIA 492 AAAC IEC 60793-2-10 A1a.3 TIA/EIA 492 AAAD Geometrical characteristics Core diameter ( μm ) 62.5 ± 2.5 50 ± 2 50 ± 2 50 ± 2 Cladding diameter ( μm ) 125 ± 1.0 125 ± 1.0 125 ± 1.0 125 ± 1.0 Coating diameter uncolored ( μm ) 242 ± 7 242 ± 5 242 ± 5 242 ± 5 ≤ 1.5 ≤1 ≤1 ≤1 Concentricity error core/cladding ( μm ) Attenuation 850 dB/km ≤ 3.2 ≤ 2.7 ≤ 2.5 ≤ 2.5 1300 dB/km ≤ 1.0 ≤ 0.8 ≤ 0.8 ≤ 0.8 r = 7.5 mm - ≤ 0.2 dB / ≤ 0.5 dB ≤ 0.2 dB / ≤ 0.5 dB ≤ 0.2 dB / ≤ 0.5 dB r = 15 mm - ≤ 0.1 dB / ≤ 0.3 dB ≤ 0.1 dB / ≤ 0.3 dB ≤ 0.1 dB / ≤ 0.3 dB 850nm ≥200 MHz/km ≥500 MHz/km ≥1500 MHz/km ≥3500 MHz/km 1300nm ≥600 MHz/km ≥500 MHz/km ≥500 MHz/km ≥500 MHz/km 850nm - - ≥2000 MHz/km ≥4700 MHz/km 1Gb/s 850nm (1000 BASE SX) 275m 750m 1000m 1100m 1Gb/s 1300nm (1000 BASE LX) 95m 550m 550m 550m 10Gb/s 850nm (10 GBASE-SR) 33m 150m 300m 550m 300m 300m 300m 300m - - 140m° 170m° SM SM A1 Bend Insensitive SM A2 Bend Insensitive NZ-DS IEC 60793-2-50 B.1.3 ITU G.652.D IEC 60793-2-50 B.1.3 & B.6.A ITU G.657.A1 IEC 60793-2-50 B.1.3 & B.6.A&B ITU G.657.A2&B2 IEC 60793-2-50 B4/B5 ITU G.655E/G656 Cladding diameter ( μm ) 125 ± 0.7 125 ± 0.7 125 ± 0.7 125 ± 1 Coating diameter uncolored ( μm ) 242 ± 7 242 ± 7 242 ± 7 242 ± 7 Bending Loss 850/1300nm 2 tuns Bandwidth Overfilled launch (OFL) Effective laser launch is assured using DMD* Maximum link length 10Gb/s 1300nm (10 GBASE-LX4) 40-100Gb/s 850nm (40/100 GBASE-SR) * as specified in EN 60793-1-49 ° total link attenuation max 1.5 dB FIBER CATEGORY SINGLE-MODE STANDARD AND NORMS Geometrical characteristics Cladding non-circularity ( % ) ≤ 0.7 ≤ 0.7 ≤ 0.7 ≤1 Concentricity error core/cladding ( μm ) ≤ 0.5 ≤ 0.5 ≤ 0.5 ≤ 0.6 Attenuation 1310nm dB/km 0.33 - 0.35 0.33 - 0.35 0.33 - 0.35 ≤ 0.40 1383nm dB/km 0.32 - 0.35 0.32 - 0.35 0.32 - 0.35 ≤ 1.0 1460nm dB/km 0.25 0.25 0.25 - 1550nm dB/km 0.19 - 0.20 0.19 - 0.20 0.19 - 0.20 ≤ 0.25 1625nm dB/km 0.20 - 0.21 0.20 - 0.21 0.20 - 0.21 ≤ 0.28 1550nm - - ≤ 0.50 dB - 1625nm - - ≤ 1.00 dB - Bending Loss 1 Turn, r 7.5 mm 1 Turn, r 10 mm 10 Turns, r 15 mm 1550nm - ≤ 0.75 dB ≤ 0.10 dB - 1625nm - ≤ 1.50 dB ≤ 0.20 dB - 1550nm - ≤ 0.25 dB ≤ 0.03 dB - 1625nm - ≤ 1.00 dB ≤ 0.10 dB - -10.0 to -3.0 Cromatic dispersion 1285 - 1330nm ( ps/km*nm ) ≤ ı3ı ≤ ı3ı - 1440 ( ps/km*nm ) - - - > 0.1 1530 - 1565nm ( ps/km*nm ) - - - 5.5 to 10 1565 - 1625nm ( ps/km*nm ) - - - 7.5 to 13.4 1550nm ( ps/km*nm ) ≤ 18.0 ≤ 18.0 - - 1625nm ( ps/km*nm ) ≤ 22.0 ≤ 22.0 - - Mode-field diameter At 1310 nm ( μm ) 9.0 ± 0.4 9.0 ± 0.4 8.8 ± 0.4 - At 1550 nm ( μm ) 10.1 ± 0.5 10.1 ± 0.5 9.8 ± 0.5 9.2 ± 0.5 ≤ 0.06 ≤ 0.06 ≤ 0.06 ≤ 0.06 ≤ 0.1 ≤ 0.1 ≤ 0.1 ≤ 0.20 Polarisation mode dispersion Link value ( ps/√km ) Individual fiber ( ps/√km ) OPTICAL CONNECTIVITY + FIBER MANAGEMENT SYSTEM Via Liguria, 8 - 20068 Peschiera Borromeo (MI) Italy Phone +39 02 55 30 35 36 Fax +39 02 55 30 35 37 www.openline.it