Transcript
In Win
Storage Chassis 4-Port 6Gb/s SAS/SATA Backplane
3RAMPD015500
User’s Manual 10/02/2012 No. 57 LANE 350,NANSHANG ROAD,GUEISHAN HSIANG, TAOYUAN HSIEN,,TAIWAN, R.O.C Tel:+886-3-322-9898 Fax:+883-3-321-1992 Http://www.in-win.com
1
4-port 6Gb/s SAS/SATA backplane User’s Manual 3RAMPD015500
Copyright Copyright © 2012 IN WIN DEVELOPMENT INC., Ltd... All rights reserved. Unless otherwise indicated, all materials in this manual are copyrighted by IN WIN DEVELOPMENT INC., All Rights Reserved. No part of this manual, either text or image may be used for any purpose other than internal use within purchasing company. Therefore, reproduction, modification in any form or by any means, electronic, mechanical or otherwise, for reasons other than internal use, is strictly prohibited without prior written permission. IN WIN DEVELOPMENT INC., reserves the right to make improvement and modification to the products indicated in this manual at any time. Specifications are therefore subject to change without prior notice. Information provided in this manual is intended to be accurate and reliable. However, IN WIN DEVELOPMENT INC., assumes no responsibility for its use, nor for any infringements upon the rights of third parties, which may result from its use.
Technical Support In win works hard to offer our customers maximum performance from our chassis. But in case you haveany problem with our product you can find supports from the following resources.
Web Support Detail information of our products is in our website. You can find technical updates, installation guides, FAQs technical specifications and more. Our web address is: www.in-win.com
Phone Support You can also contact In Win HQ or branch office for immediate support; contact Information is as following: In Win HQ
In Win USA
In Win UK
In Win NL
Tel:+886-3-322-9898
Tel:1-909-348-0588
Tel:+44(0)1923-219-880
Tel:+31(0)180-530-150
Fax:+886-3-321-1992
Fax:1-909-348-0599
Fax:+44(0)1923-219-881
Fax:+31(0)180-519-443
The actual product is subject to change without prior notice. In Win Development Inc. reserves the right to make final modifications.
2
4-port 6Gb/s SAS/SATA backplane User’s Manual 3RAMPD015500
Contents Technical Support Copyright Revision History Backplane Specification Backplane Layout Backplane Assembly
The actual product is subject to change without prior notice. In Win Development Inc. reserves the right to make final modifications.
3
4-port 6Gb/s SAS/SATA backplane User’s Manual 3RAMPD015500
Revision History Date Oct/02/2012
The actual product is subject to change without prior notice. In Win Development Inc. reserves the right to make final modifications.
Modification First release(V1.0)
4
4-port 6Gb/s SAS/SATA backplane User’s Manual 3RAMPD015500
6Gb/s Backplane Specification P/N:3RAMPD015500 (Version A0) PCB DIMENSION : 417.5mm X 33 mm X 1.6mm PCB LAYERS : 4 COMMUNICATION INTERFACE : SATA/SAS 6.0Gbit/s COMPATIBLE INTERFACE DC POWER CONNECTOR : 2 SATA HDD 29 PIN CONNECTOR : 4 SATA HDD 7 PIN CONNECTOR : 4 FAN CONNECTOR (4PIN) : 12 (PWM TYPE) --- 0.7A X 12 PCS ON BOARD LED : (A) HDD POWER LED (BLUE) WHEN HDD INSERT -------- ACTIVE (B) HDD ACCESS / FAIL LED (GREEN / RED) WHEN HDD R/W -------- ACTIVE (GREEN) WHEN HDD FAIL ------- ACTIVE (RED) SGPIO CONNECTOR : 1(8PIN) SGPIO SETTING (A) DISABLE (B) ENABLE ACCESS SINNAL : Always from device HDD FAIL SIGNAL INPUT CONNECTOR : 1 TEMPERATURE SETTING (A) 28 fan speed 70% (B) 38 fan speed 100% Temperature Alarm : 47 (When the temperature is less than the temperature of 44 ° C, automatic discharge alarm) FAN SPEED CONTROL : 2 TYPE (A) AUTO ---- By Temperature (B) MANUAL (a) 60% : 60% of the max fan speed (b) 80% : 80%of the max fan speed ALARM BUZZER (A) Fan fail(single beep) (B) Temperature fail(double beep)
Accommodation Chassis RS104-02 The actual product is subject to change without prior notice. In Win Development Inc. reserves the right to make final modifications.
5
4-port 6Gb/s SAS/SATA backplane User’s Manual 3RAMPD015500
Backplane Layout
(A) Power Connector x 2 Pin No.
Descriptions
1
12V
2
GND
3
GND
4
5V
Remark: When the voltage is not enough, can add to connect one S4P(A1) DC-in power
(B) Fan Connector Pin No.
Descriptions
1
GND
2
+12V
3
Fan Clock Input
4
Fan PWN Output
The actual product is subject to change without prior notice. In Win Development Inc. reserves the right to make final modifications.
6
4-port 6Gb/s SAS/SATA backplane User’s Manual 3RAMPD015500
(C)Fan Setting
Jumper Setting 1-2 Short 3-4 Short 5-6 Short 3-4 & 5-6 Open 7-8 Short
Description Alarm Reset Fan speed max 60% by temperature control Fan speed Minimize about 42% to Maximize 60% Fan speed max 80% by temperature control Fan speed Minimize about 56% to Maximize 80% Default rpm from 73%/25C to 100%/35C Temperature Fault set 55C
(D) SGPIO SIGNAL CONNECTOR Pin No.
Descriptions
Pin No.
Descriptions
1
NC
5
SG_LD
2
SG_DI
6
GND
3
GND
7
SG_CK
4
SG_DO
8
GND
The actual product is subject to change without prior notice. In Win Development Inc. reserves the right to make final modifications.
7
4-port 6Gb/s SAS/SATA backplane User’s Manual 3RAMPD015500
(E) SGPIO CODE PROGRAMMING PIN (F) HDD Fail signal input Pin No.
Descriptions
1
HDD1
2
HDD2
3
HDD3
4
HDD4
(G) SGPIO Setting Pin No.
Descriptions
1/2
SGPIO Disable
2/3
SGPIO Enable
(H) DC output connector for Slim CD-ROM power supply (I) SATA HDD 7 PIN CONNECTOR x4 The actual product is subject to change without prior notice. In Win Development Inc. reserves the right to make final modifications.
8
4-port 6Gb/s SAS/SATA backplane User’s Manual 3RAMPD015500
LED indicator
LED Power Led HDD Led HDD Led
Status Power On Active Fail
Color Blue Green Red
Backplane Assembly The In Win 4-Port 6Gb/s Backplane can be assembled on In Win Storage Server Chassis RS104-02. Please refer to the chassis Quick Installation Guide.
The actual product is subject to change without prior notice. In Win Development Inc. reserves the right to make final modifications.
9