NVLAP LAB CODE: 200925-0
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303) 442-1255
•
FAX: (970) 535-3114
•
INDEPENDENT TESTING LABORATORIES, INC. 4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
E-MAIL:
[email protected]
•
WEBSITE: www.itlboulder.com
REPORT NUMBER: ITL81782 PAGE: 1 OF 7 ISSUE DATE: 06/11/14 PREPARED FOR: RAB LIGHTING, INC. CATALOG NUMBER: HNLED18 (NARROW SPOT) LUMINAIRE: CAST METAL HOUSING, BROWN PAINTED FLAT METAL HEAT SINK MOUNTING PLATE, CAST BROWN PAINTED FINNED METAL HEAT SINK, 1 CIRCUIT BOARD WITH 1 LED, MOLDED PLASTIC REFLECTOR WITH SPECULAR FINISH AND CLEAR PLASTIC CONVEX INNER LENS WITH 3 INTEGRAL MOUNTING POSTS, MOLDED WHITE PLASTIC FORWARD REFLECTOR MOUNTING CYLINDER, CLEAR FLAT GLASS LENS WITH HOLOGRAPHIC PLASTIC INTERIOR OVERLAY IN CAST BROWN PAINTED METAL FRAME. LAMP: ONE WHITE MULTI-CHIP LIGHT EMITTING DIODE (LED), AIMED AT THE HORIZON. TOTAL INPUT WATTS = 19.8 AT 120.0 VOLTS LED DRIVER: RAB LIGHTING RD12-36-A0500 NOTE: DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED AT RATED INPUT VOLTAGE (120VAC, 60Hz) TO THE DRIVER. TEST PROCEDURE: IESNA LM-79-08 TEST DISTANCE = 20.0 FEET FLOODLIGHT CHARACTERISTICS AXIAL CANDLEPOWER
IES TYPE 2H X 2V MAXIMUM CANDLEPOWER 17974. AT 0.0 H, HORIZONTAL BEAM ANGLE (50%) 15.6 deg VERTICAL BEAM ANGLE (50%) 16.2 deg HORIZONTAL FIELD ANGLE (10%) 28.1 deg VERTICAL FIELD ANGLE (10%) 28.4 deg BEAM LUMENS (% FIXTURE) 812. ( 43.1 FIELD LUMENS (% FIXTURE) 1351. ( 71.6 TOTAL LUMENS (% FIXTURE) 1886. (100.0 EFFICACY = 95.3 lm/W
3 7/8
5 1/2
Checked
M KLOPF
Approved
R BEATTIE Lighting Engineer
0.0 V
% ) % ) % )
DEG
HORIZ.
DEG
VERT.
90.0 85.0 75.0 65.0 55.0 47.5 42.5 37.5 33.0 29.0 25.5 22.5 19.5 17.0 15.0 13.0 11.0 9.0 7.0 5.0 3.0 1.0 0.0 -1.0 -3.0 -5.0 -7.0 -9.0 -11.0 -13.0 -15.0 -17.0 -19.5 -22.5 -25.5 -29.0 -33.0 -37.5 -42.5 -47.5 -55.0 -65.0 -75.0 -85.0 -90.0
0. 1. 16. 41. 65. 81. 92. 109. 139. 173. 226. 310. 476. 760. 1288. 2357. 4237. 7011. 10358. 13590. 16260. 17778. 17974. 17778. 16260. 13590. 10358. 7011. 4237. 2357. 1288. 760. 476. 310. 226. 173. 139. 109. 92. 81. 65. 41. 16. 1. 0.
90.0 85.0 75.0 65.0 55.0 47.5 42.5 37.5 33.0 29.0 25.5 22.5 19.5 17.0 15.0 13.0 11.0 9.0 7.0 5.0 3.0 1.0 0.0 -1.0 -3.0 -5.0 -7.0 -9.0 -11.0 -13.0 -15.0 -17.0 -19.5 -22.5 -25.5 -29.0 -33.0 -37.5 -42.5 -47.5 -55.0 -65.0 -75.0 -85.0 -90.0
0. 0. 12. 39. 61. 77. 87. 104. 133. 170. 225. 304. 451. 721. 1158. 2094. 3944. 6749. 10162. 13491. 16146. 17707. 17974. 17893. 16715. 14464. 11470. 8196. 5208. 2987. 1622. 920. 524. 325. 234. 180. 145. 115. 95. 83. 66. 41. 16. 1. 0.
ALL CANDELA AND LUMEN VALUES IN THIS REPORT ARE BASED ON ABSOLUTE PHOTOMETRY. THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
INDEPENDENT TESTING LABORATORIES, INC. 4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303) 442-1255
•
FAX: (970) 535-3114
•
E-MAIL:
[email protected]
•
WEBSITE: www.itlboulder.com
REPORT NUMBER: ITL81782 ISSUE DATE: 06/11/14 PREPARED FOR: RAB LIGHTING, INC.
PAGE: 2 OF 7
CANDELA TABULATION AVERAGE OF RIGHT AND LEFT SIDES 0.0
1.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0
17.0
19.5
22.5
25.5
29.0
33.0
37.5
42.5
47.5
55.0
65.0
75.0
85.0
90.0
90.0
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
85.0
0.
0.
0.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
75.0
12.
12.
12.
13.
13.
13.
14.
14.
14.
14.
14.
13.
13.
12.
11.
9.
8.
7.
4.
2.
1.
0.
0.
65.0
39.
39.
39.
39.
38.
38.
38.
37.
37.
36.
36.
35.
33.
31.
29.
26.
23.
19.
13.
7.
2.
0.
0.
55.0
61.
61.
61.
61.
61.
61.
60.
60.
59.
58.
57.
56.
54.
52.
49.
45.
40.
34.
25.
13.
5.
1.
0.
47.5
77.
77.
77.
77.
76.
76.
76.
75.
74.
74.
72.
70.
68.
66.
62.
58.
52.
45.
34.
19.
7.
1.
0.
42.5
87.
88.
88.
89.
92.
86.
86.
85.
85.
84.
85.
81.
78.
75.
70.
65.
59.
52.
40.
23.
8.
1.
0.
37.5
104.
104.
103.
103.
102.
101.
99.
98.
97.
95.
93.
91.
88.
84.
79.
73.
65.
58.
45.
26.
10.
1.
0.
33.0
133.
132.
132.
130.
128.
125.
121.
118.
114.
111.
107.
102.
98.
92.
86.
79.
71.
63.
50.
29.
11.
1.
0.
29.0
170.
169.
168.
165.
161.
156.
151.
144.
138.
132.
125.
117.
109.
101.
93.
88.
75.
66.
53.
32.
12.
1.
0.
25.5
225.
224.
222.
215.
206.
195.
184.
174.
164.
155.
145.
132.
121.
109.
98.
89.
79.
69.
56.
34.
13.
1.
0.
22.5
304.
303.
299.
288.
273.
254.
233.
213.
194.
178.
162.
146.
132.
118.
104.
92.
82.
72.
57.
35.
13.
1.
0.
19.5
451.
449.
437.
412.
379.
343.
304.
270.
238.
210.
182.
159.
143.
126.
110.
96.
84.
74.
59.
37.
14.
1.
0.
17.0
721.
716.
684.
622.
547.
467.
395.
336.
286.
244.
205.
172.
151.
133.
115.
98.
86.
76.
60.
38.
14.
1.
0.
15.0
1158. 1146. 1072.
951.
792.
642.
511.
409.
335.
279.
228.
185.
159.
139.
119.
101.
88.
77.
61.
38.
15.
1.
0.
13.0
2094. 2102. 1888. 1596. 1254.
942.
705.
524.
401.
319.
253.
200.
167.
145.
123.
103.
89.
78.
62.
39.
15.
1.
0.
11.0
3944. 3950. 3498. 2834. 2118. 1480. 1016.
709.
502.
372.
283.
218.
177.
151.
127.
105.
90.
79.
63.
40.
15.
1.
0.
9.0
6749. 6654. 5978. 4818. 3540. 2368. 1503.
966.
645.
442.
316.
236.
187.
157.
131.
106.
91.
79.
63.
40.
15.
1.
0.
7.0 10162.10023. 9011. 7352. 5359. 3569. 2179. 1294.
811.
528.
354.
256.
198.
162.
134.
107.
91.
80.
64.
40.
15.
1.
0.
5.0 13491.13255.12076. 9930. 7377. 4885. 2948. 1688.
986.
615.
395.
276.
208.
167.
136.
108.
92.
80.
64.
41.
16.
1.
0.
3.0 16146.15916.14547.12018. 9070. 6069. 3656. 2044. 1144.
692.
432.
293.
217.
170.
138.
109.
92.
81.
64.
41.
16.
1.
0.
1.0 17707.17488.16006.13328. 9720. 6844. 4131. 2296. 1261.
746.
463.
306.
224.
173.
139.
109.
92.
81.
65.
41.
16.
1.
0.
0.0 17974.17778.16260.13590.10358. 7011. 4237. 2357. 1288.
760.
476.
310.
226.
173.
139.
109.
92.
81.
65.
41.
16.
1.
0.
-1.0 17893.17719.16208.13576. 9933. 7014. 4243. 2358. 1291.
764.
479.
313.
226.
174.
139.
109.
92.
81.
65.
41.
16.
1.
0.
-3.0 16715.16558.15179.12745. 9682. 6551. 3961. 2203. 1226.
744.
468.
311.
226.
173.
138.
109.
92.
80.
64.
41.
16.
1.
0.
-5.0 14464.14343.13136.10959. 8300. 5579. 3369. 1892. 1093.
691.
449.
302.
221.
171.
136.
108.
91.
80.
64.
41.
16.
1.
0.
-7.0 11470.11313.10383. 8551. 6437. 4304. 2613. 1516.
932.
618.
417.
288.
214.
167.
134.
106.
91.
80.
64.
40.
16.
1.
0.
-9.0
8196. 8035. 7343. 5992. 4501. 3013. 1879. 1169.
770.
537.
378.
271.
205.
162.
130.
105.
90.
79.
64.
40.
15.
1.
0.
-11.0
5208. 5088. 4658. 3784. 2870. 1969. 1302.
880.
622.
460.
339.
251.
194.
156.
126.
103.
89.
78.
63.
40.
15.
1.
0.
-13.0
2987. 2904. 2682. 2204. 1724. 1261.
901.
664.
501.
391.
302.
230.
183.
149.
122.
100.
88.
77.
62.
39.
15.
1.
0.
-15.0
1622. 1578. 1481. 1276. 1050.
829.
650.
510.
409.
334.
268.
211.
171.
142.
117.
98.
86.
76.
62.
39.
15.
1.
0.
-17.0
920.
912.
863.
780.
680.
573.
480.
401.
337.
287.
238.
193.
161.
135.
112.
95.
85.
75.
61.
38.
15.
1.
0.
-19.5
524.
522.
505.
476.
439.
394.
350.
310.
273.
240.
206.
174.
149.
126.
106.
93.
83.
74.
60.
37.
14.
1.
0.
-22.5
325.
325.
320.
312.
297.
280.
259.
239.
217.
198.
177.
155.
135.
116.
100.
89.
80.
71.
58.
36.
14.
1.
0.
-25.5
234.
233.
232.
228.
221.
213.
202.
191.
180.
168.
154.
137.
122.
107.
95.
86.
77.
69.
56.
34.
13.
1.
0.
-29.0
180.
180.
179.
178.
175.
170.
164.
157.
150.
142.
131.
119.
109.
98.
90.
86.
74.
66.
54.
32.
12.
1.
0.
-33.0
145.
145.
144.
143.
140.
137.
132.
127.
122.
117.
111.
104.
98.
91.
87.
78.
70.
63.
50.
30.
11.
1.
0.
-37.5
115.
115.
114.
113.
111.
109.
106.
104.
101.
99.
96.
93.
89.
84.
79.
72.
66.
59.
46.
27.
10.
1.
0.
-42.5
95.
95.
94.
94.
93.
92.
91.
90.
88.
87.
85.
83.
80.
76.
72.
66.
60.
53.
41.
23.
8.
1.
0.
-47.5
83.
83.
84.
82.
81.
80.
80.
78.
78.
77.
75.
73.
71.
68.
64.
59.
53.
46.
35.
20.
7.
1.
0.
-55.0
66.
66.
65.
65.
65.
64.
63.
63.
62.
61.
60.
58.
57.
54.
51.
46.
41.
35.
26.
14.
5.
1.
0.
-65.0
41.
41.
41.
41.
41.
40.
40.
39.
39.
38.
37.
36.
35.
33.
30.
28.
24.
20.
14.
7.
3.
0.
0.
-75.0
16.
16.
16.
16.
16.
16.
16.
16.
16.
15.
15.
14.
14.
13.
11.
10.
8.
7.
5.
3.
1.
0.
0.
-85.0
1.
1.
1.
2.
2.
2.
2.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
0.
0.
0.
0.
-90.0
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
BEAM EDGE = FIELD EDGE =
8987. CP = 50% OF MAX 1797. CP = 10% OF MAX
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303) 442-1255
•
FAX: (970) 535-3114
•
INDEPENDENT TESTING LABORATORIES, INC. 4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
E-MAIL:
[email protected]
•
WEBSITE: www.itlboulder.com
REPORT NUMBER: ITL81782 ISSUE DATE: 06/11/14 PREPARED FOR: RAB LIGHTING, INC.
PAGE: 3 OF 7
CANDELA TABULATION - FIELD ONLY AVERAGE OF RIGHT AND LEFT SIDES 0.0
1.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0
17.0
19.5
22.5
25.5
29.0
33.0
37.5
42.5
47.5
55.0
65.0
75.0
85.0
90.0
90.0 85.0 75.0 65.0 55.0 47.5 42.5 37.5 33.0 29.0 25.5 22.5 19.5 17.0 15.0 13.0
2094. 2102. 1888.
11.0
3944. 3950. 3498. 2834. 2118.
9.0
6749. 6654. 5978. 4818. 3540. 2368.
7.0 10162.10023. 9011. 7352. 5359. 3569. 2179. 5.0 13491.13255.12076. 9930. 7377. 4885. 2948. 3.0 16146.15916.14547.12018. 9070. 6069. 3656. 2044. 1.0 17707.17488.16006.13328. 9720. 6844. 4131. 2296. 0.0 17974.17778.16260.13590.10358. 7011. 4237. 2357. -1.0 17893.17719.16208.13576. 9933. 7014. 4243. 2358. -3.0 16715.16558.15179.12745. 9682. 6551. 3961. 2203. -5.0 14464.14343.13136.10959. 8300. 5579. 3369. 1892. -7.0 11470.11313.10383. 8551. 6437. 4304. 2613. -9.0
8196. 8035. 7343. 5992. 4501. 3013. 1879.
-11.0
5208. 5088. 4658. 3784. 2870. 1969.
-13.0
2987. 2904. 2682. 2204.
-15.0 -17.0 -19.5 -22.5 -25.5 -29.0 -33.0 -37.5 -42.5 -47.5 -55.0 -65.0 -75.0 -85.0 -90.0
BEAM EDGE = FIELD EDGE =
8987. CP = 50% OF MAX 1797. CP = 10% OF MAX
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
INDEPENDENT TESTING LABORATORIES, INC. 4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303) 442-1255
•
FAX: (970) 535-3114
•
E-MAIL:
[email protected]
•
WEBSITE: www.itlboulder.com
REPORT NUMBER: ITL81782 ISSUE DATE: 06/11/14 PREPARED FOR: RAB LIGHTING, INC.
PAGE: 4 OF 7
LUMEN TABULATION AVERAGE OF RIGHT AND LEFT SIDES 0
2
4
6
8
10
12
14
16
18
21
24
27
31
35
40
45
50
60
70
80
90
TOTAL
90 0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
2.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
5.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
1.
1.
1.
0.
0.
0.
0.
0.
0.
8.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
5.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
6.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
6.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
6.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
7.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
6.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
7.
1.
1.
1.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
9.
1.
1.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
8.
1.
1.
1.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
10.
3.
2.
2.
2.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
14.
5.
4.
3.
3.
2.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
23.
8.
7.
6.
4.
3.
2.
1.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
35.
12.
11.
9.
6.
4.
3.
2.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
52.
16.
15.
12.
9.
6.
4.
2.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
68.
19.
18.
15.
11.
7.
4.
2.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
82.
21.
19.
16.
12.
8.
5.
3.
1.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
90.
22.
20.
16.
12.
8.
5.
3.
2.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
92.
20.
18.
15.
12.
8.
5.
3.
1.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
87.
17.
16.
13.
10.
7.
4.
2.
1.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
75.
14.
13.
10.
8.
5.
3.
2.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
60.
10.
9.
7.
5.
4.
2.
1.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
43.
6.
6.
5.
3.
2.
2.
1.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
29.
4.
3.
3.
2.
2.
1.
1.
1.
0.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
19.
2.
2.
2.
1.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
12.
1.
1.
1.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
9.
1.
1.
1.
1.
1.
1.
1.
0.
0.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
10.
1.
1.
1.
1.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
8.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
6.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
7.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
6.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
7.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
6.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
5.
0.
0.
0.
0.
0.
0.
0.
0.
0.
1.
0.
0.
1.
1.
1.
0.
0.
0.
0.
0.
0.
8.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
5.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
2.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
191.
175.
146.
111.
78.
51.
33.
22.
17.
19.
15.
13.
14.
12.
12.
10.
8.
11.
5.
1.
0.
943.
80 70 60 50 45 40 35 31 27 24 21 18 16 14 12 10 8 6 4 2 0 -2 -4 -6 -8 -10 -12 -14 -16 -18 -21 -24 -27 -31 -35 -40 -45 -50 -60 -70 -80 -90
LUMEN TOTAL THIS PAGE =
943.
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
INDEPENDENT TESTING LABORATORIES, INC. 4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303) 442-1255
•
FAX: (970) 535-3114
•
E-MAIL:
[email protected]
•
WEBSITE: www.itlboulder.com
REPORT NUMBER: ITL81782 ISSUE DATE: 06/11/14 PREPARED FOR: RAB LIGHTING, INC.
PAGE: 5 OF 7
LUMEN TABULATION - FIELD ONLY AVERAGE OF RIGHT AND LEFT SIDES 0
2
4
6
8
10
12
14
16
18
21
24
27
31
35
40
45
50
60
70
80
90
TOTAL
90 0. 80 0. 70 0. 60 0. 50 0. 45 0. 40 0. 35 0. 31 0. 27 0. 24 0. 21 0. 18 0. 16 0. 14 3.
2.
5.
4.
3.
3.
5.
12 15.
10 8.
7.
6.
4.
3.
12.
11.
9.
6.
4.
3.
28.
16.
15.
12.
9.
6.
4.
19.
18.
15.
11.
7.
4.
2.
77.
21.
19.
16.
12.
8.
5.
3.
85.
22.
20.
16.
12.
8.
5.
3.
86.
20.
18.
15.
12.
8.
5.
3.
81.
17.
16.
13.
10.
7.
4.
2.
70.
14.
13.
10.
8.
5.
3.
53.
10.
9.
7.
5.
4.
2.
37.
6.
6.
5.
3.
2.
4.
3.
3.
8 45.
6 61.
4 2 0 -2 -4 -6 -8 -10 22.
-12 9.
-14 0. -16 0. -18 0. -21 0. -24 0. -27 0. -31 0. -35 0. -40 0. -45 0. -50 0. -60 0. -70 0. -80 0. -90 177.
161.
131.
95.
63.
35.
13.
0.
0.
0.
0.
LUMEN TOTAL THIS PAGE =
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
675.
675.
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303) 442-1255
•
FAX: (970) 535-3114
•
INDEPENDENT TESTING LABORATORIES, INC. 4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
E-MAIL:
[email protected]
•
REPORT NUMBER: ITL81782 ISSUE DATE: 06/11/14 PREPARED FOR: RAB LIGHTING, INC.
WEBSITE: www.itlboulder.com
PAGE: 6 OF 7
ISOCANDELA CURVES AVERAGE OF RIGHT AND LEFT SIDES
20
0
2
4
6
8
10
12
14
16
18
20
18 16 14 12
17000 14000
10
12000 8987 (= 50% MAX)
8 6
7000 5000 4000
4
1797 (= 10% MAX)
2 0 -2 -4 -6 -8 -10 -12 -14 -16 -18 -20 0
2
4
6
8
10
12
14
16
18
20
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303) 442-1255
•
FAX: (970) 535-3114
•
REPORT NUMBER: ITL81782 ISSUE DATE: 06/11/14 PREPARED FOR: RAB LIGHTING, INC.
INDEPENDENT TESTING LABORATORIES, INC. 4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
E-MAIL:
[email protected]
•
WEBSITE: www.itlboulder.com
PAGE: 7 OF 7
ADDRESS: 170 LUDLOW AVE NORTHVALE, NJ 07647
THIS ITL REPORT WITH THE USE OF THE NVLAP LOGO SHALL NOT BE USED BY THE CLIENT TO CLAIM PRODUCT CERTIFICATION, APPROVAL, OR ENDORSEMENT BY NVLAP, NIST, OR ANY AGENCY OF THE FEDERAL GOVERNMENT.
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303)442-1255
•
FAX: (970)535-3114
•
INDEPENDENT TESTING LABORATORIES, INC. 4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
E-MAIL:
[email protected]
•
WEBSITE: www.itlboulder.com
REPORT NUMBER: DATE: PREPARED FOR: CATALOG NUMBER:
ITL81809 06/19/14 RAB LIGHTING, INC. HNLED18 (NARROW SPOT)
Page 1 of 4
ADDRESS:
170 LUDLOW AVE NORTHVALE, NJ 07647
LUMINAIRE:
CAST METAL HOUSING, BROWN PAINTED FLAT METAL HEAT SINK MOUNTING PLATE, CAST BROWN PAINTED FINNED METAL HEAT SINK, 1 CIRCUIT BOARD WITH 1 LED, MOLDED PLASTIC REFLECTOR WITH SPECULAR FINISH AND CLEAR PLASTIC CONVEX INNER LENS WITH 3 INTEGRAL MOUNTING POSTS, MOLDED WHITE PLASTIC FORWARD REFLECTOR MOUNTING CYLINDER, CLEAR FLAT GLASS LENS WITH HOLOGRAPHIC PLASTIC INTERIOR OVERLAY IN CAST BROWN PAINTED METAL FRAME.
LAMP:
ONE WHITE MULTI-CHIP LIGHT EMITTING DIODE (LED), AIMED AT THE HORIZON.
DRIVER:
RAB LIGHTING RD12-36-A0500
NOTE:
DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED AT RATED INPUT VOLTAGE (120.0 AND 277.0 VAC, 60Hz) TO THE DRIVER. Calibration Due: Associated Power Technologies APT5040 AC Power Source N/A Yokogawa WT210 Digital Power Meter #8 12/31/14 Ocean Optics QE65000 Spectroradiometer 04/13/14 ITL 2.0m Diameter Integrating Sphere S20-2, 4PI Geometry 04/13/14
INSTRUMENTS:
OBJECT OF TEST:
Measure the Total Radiant Flux*, Spectral Power Distribution (SPD), Correlated Color Temperature (CCT), Color Rendering Indices (CRIa,1-14), Chromaticity Coordinates (x,y; u’v’), ANSI C78.377 Duv, and electrical data including ANSI C82.77-2002 Power Factor (PF) and Total Harmonic Distortion (THD) to the test sample. Report Off-State Power. Measure electrical data including Total Harmonic Distortion (THD) at maximum rated voltage.
PROCEDURE:
The test sample was provided by the customer and had an unknown number of operating hours. The test sample was mounted inside the integrating sphere and allowed to stabilize. After stabilization occurred, measurements were taken. In order to measure mean performance, multiple data sets were recorded and averaged. Readings were taken with the test sample operating at 120.0 VAC input. Electrical data was also recorded at maximum nominal rated input voltage (277.0 VAC). All testing performed in a 25 +/-1 degree Celsius free air ambient and in accordance with IESNA LM-79-08. All data are traceable to the National Institute of Standards and Technology. Off-State Power was reported with no voltage applied to the sample.
*NOTE:
Proper calibration of integrating spheres for measuring total flux output of non-directional samples will produce reliable, repeatable results within the calibration tolerances of the equipment used. However, measurement of test samples with significant self absorption and/or directional output, even when these effects are compensated for, are likely to have a greater variation in results compared to the flux output calculated from a goniophotometric exploration since these artifacts do not affect the goniophotometric results.
RESULTS:
(continued subsequent pages)
THIS ITL REPORT WITH THE USE OF THE NVLAP LOGO SHALL NOT BE USED BY THE CLIENT TO CLAIM PRODUCT CERTIFICATION, APPROVAL, OR ENDORSEMENT BY NVLAP, NIST, OR ANY AGENCY OF THE FEDERAL GOVERNMENT. Checked Approved
N THOMAS P O’CONNOR Sphere Lab Supervisor
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303)442-1255
REPORT NUMBER: DATE: PREPARED FOR: CATALOG NUMBER:
•
FAX: (970)535-3114
•
INDEPENDENT TESTING LABORATORIES, INC. 4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
E-MAIL:
[email protected]
ITL81809 06/19/14 RAB LIGHTING, INC. HNLED18 (NARROW SPOT)
•
WEBSITE: www.itlboulder.com
Page 4 of 4
CIE Chromaticity Diagram
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303)442-1255
REPORT NUMBER: DATE: PREPARED FOR: CATALOG NUMBER:
•
FAX: (970)535-3114
•
INDEPENDENT TESTING LABORATORIES, INC. 4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
E-MAIL:
[email protected]
ITL81809 06/19/14 RAB LIGHTING, INC. HNLED18 (NARROW SPOT)
•
WEBSITE: www.itlboulder.com
Page 2 of 4
RESULTS: SPECTRORADIOMETRIC Observer Chromaticity Ordinate x Chromaticity Ordinate y Observer Chromaticity Ordinate u’ Chromaticity Ordinate v’ Correlated Color Temp CCT (K) ANSI C78.377-2008 Duv Total Radiant Flux (milliWatts)
CIE 1931 2 degree 0.3462 0.3870 CIE 1976 2 degree 0.1992 0.5010 5063 0.016 5271 *
ELECTRICAL Input Voltage (Volts AC) Input Current (Amps AC) Input Power (Watts) Input Power Factor (%) Input Current THD (%) Input Voltage THD (%)
120.0 0.166 19.8 99.4 10.4 0.1
Off-State Power (Watts)
0.0
ELECTRICAL AT MAX NONIMAL INPUT Input Voltage (Volts AC) Input Current (Amps AC) Input Power (Watts) Input Power Factor (%) Input Current THD (%) Input Voltage THD (%)
*NOTE:
COLOR RENDERING INDICES Ra (Average 1-8) R1 Light greyish red R2 Dark greyish yellow R3 Strong yellowish green R4 Moderate yellowish green R5 Light bluish green R6 Light blue R7 Light violet R8 Light reddish purple R9 Strong red R10 Strong yellow R11 Strong green R12 Strong blue R13 Light yellowish pink (skin) R14 Moderate olive green (leaf)
CRI 67 61 73 82 66 62 63 83 50 -55 36 59 30 63 90
277.0 0.080 20.3 91.6 20.6 0.1
Proper calibration of integrating spheres for measuring total flux output of non-directional samples will produce reliable, repeatable results within the calibration tolerances of the equipment used. However, measurement of test samples with significant self absorption and/or directional output, even when these effects are compensated for, are likely to have a greater variation in results compared to the flux output calculated from a goniophotometric exploration since these artifacts do not affect the goniophotometric results.
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303)442-1255
REPORT NUMBER: DATE: PREPARED FOR: CATALOG NUMBER:
•
FAX: (970)535-3114
•
INDEPENDENT TESTING LABORATORIES, INC. 4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
E-MAIL:
[email protected]
ITL81809 06/19/14 RAB LIGHTING, INC. HNLED18 (NARROW SPOT)
•
WEBSITE: www.itlboulder.com
Page 3 of 4
RESULTS: Wavelength 380 385 390 395 400 405 410 415 420 425 430 435 440 445 450 455 460 465 470 475 480 485 490 495 500 505 510
mW per nm 0.138 0.137 0.147 0.173 0.215 0.310 0.531 0.997 1.900 3.535 6.322 10.617 16.720 26.347 37.754 39.563 28.959 18.930 13.385 9.452 6.870 5.907 6.050 7.196 9.579 13.036 17.124
Wavelength 515 520 525 530 535 540 545 550 555 560 565 570 575 580 585 590 595 600 605 610 615 620 625 630 635 640 645
mW per nm 21.156 24.726 27.598 29.714 31.122 32.006 32.475 32.638 32.606 32.376 31.999 31.436 30.691 29.823 28.783 27.590 26.289 24.862 23.383 21.882 20.287 18.714 17.180 15.659 14.249 12.923 11.639
Wavelength 650 655 660 665 670 675 680 685 690 695 700 705 710 715 720 725 730 735 740 745 750 755 760 765 770 775 780
mW per nm 10.472 9.392 8.386 7.462 6.620 5.863 5.189 4.573 4.031 3.542 3.090 2.704 2.375 2.093 1.840 1.615 1.418 1.241 1.091 0.958 0.845 0.741 0.651 0.572 0.501 0.440 0.388
Output vs. Wavelength
42.5
Output (mW/nm)
34.0
25.5
17.0
8.5
0.0 380.0
420.0
460.0
500.0
540.0 580.0 620.0 Wavelength (nm)
660.0
700.0
740.0
780.0
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.