Preview only show first 10 pages with watermark. For full document please download

Indoor-abolite Rlm_downlights_commfluorescent

   EMBED


Share

Transcript

LSI ABOLITE GLOBES PG3 • Full heat- and impact-resistant 3" diameter prismatic Glass Globe offers symmetrical light pattern. Globe 3-7/8" (48mm) screws into cast aluminum holder. • 4-pin lamp holder supplied for 26, 32, and 42 Watt Compact Fluorescent lamps. • 4KV medium base lamp holder supplied for use with Incandescent and 7-1/2" (191mm) HID lamps. • Globe factory assembled to the RD, BD, RWD, AD200 or HMDM reflector of your choice. G6 • Frosted 6" diameter (152mm) Glass Globe offers symmetrical light pattern. Globe screws into cast aluminum holder. 3-7/8" • 4-Pin lamp holder supplied for (98mm) 26, 32, and 42 Watt Compact Fluorescent lamps. • Medium base lamp holder supplied for use with 7-1/4" Incandescent lamps. (184mm) • Globe factory assembled to the RD, BD, RWD, or HMDM reflector of your choice (also available on AD 200). 3-3/8" (86mm) 6" (152mm) wet location Option PG3 Description 3" Diameter (76mm) Ribbed Clear Glass Assembly PG3FG 3" Diameter (76mm) Ribbed Frosted Glass Assembly Lamp Socket Maximum Wattage Restrictions 4 PIN Medium Medium Medium 26/32/42 Compact Fluorescent 200 Incandescent 100 Metal Halide 1 175 Pulse-Start Metal Halide wet location Option Description G6 6" Diameter (152mm) White Opal Glass Lamp Socket 4 PIN Medium Maximum Wattage Restrictions 26/32/42 Compact Fluorescent 75 Incandescent No Metal Halide 1- Requires the use of Medium Base Reduced Envelope Lamp. ACCESSORIES Accessories 3" Globe Guard ST TYPE STEMS: Thread Notes 3/4" NPT • 3/4" NPT rigid aluminum 3/4 – 14 NPS conduit stem features (3/4" Pipe) gloss powder coat finish. (14 Threads Per Inch) (National Pipe Tapered) • White powder finish is Various Lengths standard; other optional colors available. 1-3/64" 3/4" 1-3/64" COG TYPE WIRE GUARDS: • All have center opening for relamping (except COG3 and COG4). • Metallic silver powder finish standard (except COG3 and COG4 are gloss white); other optional colors available. 4" Globe Guard 8-1/2" (216mm) 6-5/8" 168mm) 4-5/8" (117mm) • All wire guards are convex type except COG20F MSV, COG 14 F, COG 14 N, COG 18 F, and COG18 N which are flat, COG3 WHT, and COG4 WHT which fits PG3, and PG4 globes. 5-1/2" (140mm) Convex Guard Ref. Fixture Dia. STEM ORDERING DATA ST 6 3 GWT ST 12 3 GWT ST 18 3 GWT ST 24 3 GWT ST 36 3 GWT ST 48 3 GWT ST 60 3 GWT ST 72 3 GWT COP 3 GWT 3/4" x 6" Rigid Conduit Stem All Rigid Conduit 3/4" x 12" Rigid Conduit Stem Stems Are 3/4" x 18" Rigid Conduit Stem Finished With 3/4" x 24" Rigid Conduit Stem 3/4" x 36" Rigid Conduit Stem Gloss White 3/4" x 48" Rigid Conduit Stem Powder 3/4" x 60" Rigid Conduit Stem 3/4" x 72" Rigid Conduit Stem 3/4" Coupling for joining stem sections NOTE: Stems do not include canopies – Order Separately REDUCING BUSHING 3/4" TO 1/2": • Fits RLM top casting to adapt fixture for 1/2" stems. Part # 133834 3/4 – 14 NPS (3/4" Pipe) (14 Threads Per Inch) (National Pipe Straight) 1/2 – 14 NPS (1/2" Pipe) (14 Threads Per Inch) (National Pipe Straight) I N DOOR 1-3/64" 9/16" COG 3 GWT COG 7 MSV COG 9 MSV COG 10 MSV COG 11 MSV COG 12 MSV COG 13 MSV COG 14 MSV COG 16 MSV COG 18 MSV COG 20 F MSV 3" Globe Wire Guard Finished Gloss White Powder (For use with PG3 Globe Option) 4" Globe Wire Guard Finished Gloss White Powder (For use with PG4 on Harbor Series) 7" Convex Wire Guard (AD 100 guard) 9" Convex Wire Guard (AD 150 guard) 10" Convex Wire Guard (BD 200 guard) 11" Convex Wire Guard (AD 200 guard) 12" Convex Wire Guard (RD 100 guard) 13" Convex Wire Guard (BD 300 guard) 14" Convex Wire Guard (RD 150 guard) 16" Convex Wire Guard (RD 200 guard) 18" Convex Wire Guard (RD 300 guard) 20" Flat Wire Guard (HMDM/HMDMU) COG 14 F COG 14 N COG 18 F COG 18 N 14” Flat Wire Guard (Open CHT/IHT guard) 14” Flat Wire Guard (Enclosed CHT/IHT guard) 18” Flat Wire Guard (Open CHT/IHT guard) 18” Flat Wire Guard (Enclosed CHT/IHT guard) COG 4 GWT Zinc Plated only 27/32" ARRA Funding Compliant Reducing Bushing 1/2" NPS x 3/4" NPS Project Name 286 WIRE GUARD ORDERING DATA Catalog # Fixture Type 12/06/11 © 2012 LSI INDUSTRIES INC. LSI ABOLITE ACCESSORIES BC TYPE DECORATIVE CANOPY TYPE ALIGNER: • Canopy type aligners consist of drawn steel canopy with cast ball joint assembly (for damp locations only). • Allow 3/4" stem to hang plumb when surface mounted at any angle up to 37 degrees. • White gloss finish is standard; other optional colors available. • BC600 3 GWT BC UTILITY TYPE BALL ALIGNERS: • Allow fixtures to hang plumb when suspended at angle as great as 37 degrees. • Heavy gauge steel with zinc finish. Note: All aligners listed on this page are outlet box cover type and are secured by 8-32 outlet box screws. The N.E.C. states that “a fixture which weighs more than 50 pounds shall be supported independently of the outlet box.” • BC580 ZINC - 1/2" threaded entry to accept NPT fittings. • BC585 ZINC - 3/4" threaded entry to accept NPT fittings. • BC580SQ ZINC - 1/2" threaded entry to accept NPT fittings. • BC585SQ ZINC - 3/4" threaded entry to accept NPT fittings. 3-1/2" (89mm) 6" (152mm) 1-1/4" (32mm) 2-3/4" (70mm) SOCKETS AND HOLDERS: • Medium Base Replacement Sockets tapped for 3/4" conduit. • Mogul Base Replacement Sockets tapped for 1/2” or 3/4" conduit (specify size required). Wiring not included. • RS socket designs are replacements for RLMs. • Sockets provided with cords do not include ceiling canopy. • RS7005 3/4 LDS96 - Medium Base 3/4” Socket with 96” leads • RS7005 CA120WHT - Medium Base Socket with 120” white cord • RS7005 CA120BLK - Medium Base Socket with 120” black cord • RS7006 1/2 - Mogul Base 1/2” Replacement Socket (no wiring supplied) • RS7006 3/4 - Mogul Base 3/4” Replacement Socket (no wiring supplied) • CA GWT - White replacement canopy kit (for above cord set) • CA GBK - Black replacement canopy kit (for above cord set) Medium Base 1/2" NPS or 3/4" NPS Available 3-1/2" (89mm) 4-3/4" (121mm) 4-1/8" (105mm) BC580 and BC585 Aligner Detail BC580SQ and BC585SQ Aligner Detail ENERGY CONVERSION KITS • Reduce energy requirements by switching from less efficient Incandescent RLM’s to Compact Fluorescent or Metal Halide • PG3 Globes offer weather protection in Outdoor locations • Prismatic globe reduces unprotected lamp glare. Note: CFL or MH kits require use of remote ballast – order separately. Kits do not include die cast nuts; reuse from the fixture being retrofitted. Mogul Base 3/4" (19mm) UPGCK – Conversion Kit retrofits standard Incandescent / MP open socket RLM to PG3 Globe fixture except HMDMU, AD100 and AD150. UPGCK CFL – Conversion Kit retrofits open medium base socket RLM to CFL PG3 Globe fixture except HMDMU, AD100 and AD150. 2-1/8" (54mm) 3-7/8" (98mm) 4-5/16" (110mm) American Innovation ARRA Funding Compliant American Made Project Name Catalog # Fixture Type 12/06/11 © 2012 LSI INDUSTRIES INC. 289