Transcript
Indoor Class 2 LED Driver Phase Cut Dimming 50W SKU 36535 Description: 50W SKU: 0.85A ~ 1.3A Phase Cut dimming Phase Cut Dimmable/Programmable Class 2 PSU Input Voltage: 120Vac +/-10% (UL) Input Frequency: 60Hz Compliant with Material Restrictions of RoHs Output Power (W)
Output Current (A)
Output Voltage (V)
Max Input Current (A)
50
0.85-1.3
30-50
0.5A (UL)
THD @ Full load without dimmer <20%
PF@ Full load without dimmer >0.9
Ring Wave
Combinatio Inrush Current n (A/mS) 2KV/2 ohm pass,
3KV/12ohm 6KV/2ohm fail to safe
See page below
Weight (lbs/g) 1.24lbs / 565g
Dimming Function Dimming Method
Isolation
Dimming Range (%)
Current source
Phase Cut dimming
UL Class 2
100% - 5%
Don’t need
Wiring Diagram: See label below
Product Features Physical
Unit must be installed in compliance with the applicable requirements of the endproduct standard for enclosure, mounting, spacing, casualty and segregation. Enclosure wiring must be rated to 600V & 105°C or higher.
Performance
The unit is classified as UL Class 2 as stipulated in UL1310. Program circuitry is classified as UL Class 2 as stipulated in UL1310. Minimum ambient operating temperature: -30°C. Maximum allowable casing temperature: 85°C. Audible noise free.
GE Lighting Solutions NELA Park – 1975 Noble Road East Cleveland, OH 44112 1-888-694-3533 (888-MY-GE-LED)
For reliability and failure rate information, contact CTC LED Driver Team. The unit is UL certified for operation in dry/damp locations. The unit is tolerant of extended open circuit and short circuit conditions. The unit is compliant to FCC Title 47 Part 15 Class A. The unit is resistant to surges as per ANSI C62.41 – 2002 and IEC 61000-4-5.
UL Conditions of Acceptability – E340135
The unit has been examined to comply with UL Class 2 Output Criteria The unit is only to be used in dry or damp locations The metal casing must be connected to EARTH. The “Program” circuits must remain isolated from one another to be considered UL class 2 circuits in the end use.
Product Label
GE Lighting Solutions NELA Park – 1975 Noble Road East Cleveland, OH 44112 1-888-694-3533 (888-MY-GE-LED)
Technical Information Output Voltage/Current Range (30V-50V, 0.85A – 1.3A)
Note1: The operating window just shows the driver can work in this area without abnormal functionality. Note2: For different fixtures with different output voltage, EMI should be retested by each fixture. Note3: For different fixture with different output voltage, the compatibility phase cut dimmer list should be retested by each fixture.
Phase Cut Dimmer List Condition : 36V LED output-For other fixtures with different LED output voltage, need to retest and update the list Dimmer List for 50W_885mA Phase Dimming Program
120V/60HZ
No.
Brand
Feature
1
Lutron
2
Lutron
3
Lutron
4
Lutron
5
Lutron
6
Lutron
7
Lutron
8
Lutron
9
Lutron
10
Lutron
(C32) 06631-0LW (C40) 06683-0IW (C40) 06681-0IW (011) IPI06-1LZ NT-600-WH V-600-WH (002) 06633-PLW MA-600-WH DVCL-153P-WH AY-600PNL-WH
GE Lighting Solutions NELA Park – 1975 Noble Road East Cleveland, OH 44112 1-888-694-3533 (888-MY-GE-LED)
Comments
Results OK OK OK OK OK OK OK OK Flicker OK
11
Lutron
12
Lutron
13
Lutron
14 15 16
Leviton Lutron Lutron
D-600P-WH CTCL-153P-WH MRF2-6ND-120-WH S-600P-WH
OK Flicker OK OK OK OK
DV-600P-WH DVF-103P-WH
Dimmer List for 50W_1300mA Phase Dimming Program No.
Brand
1
Lutron
2 3 4 5 6 7 120V/60HZ
8 9 10 11 12 13 14 15 16
Feature
(C32) 06631-0LW Lutron (C40) 06683-0IW Lutron (C40) 06681-0IW Lutron (011) IPI06-1LZ Lutron NT-600-WH Lutron V-600-WH Lutron (002) 06633-PLW Lutron MA-600-WH Lutron DVCL-153P-WH Lutron D-600P-WH Lutron AY-600PNL-WH Lutron CTCL-153P-WH Lutron MRF2-6ND-120-WH Leviton S-600P-WH Lutron Lutron
Comments
only flicker when Iout <30mA
DV-600P-WH DVF-103P-WH
Technical Information GE Lighting Solutions NELA Park – 1975 Noble Road East Cleveland, OH 44112 1-888-694-3533 (888-MY-GE-LED)
Results
OK OK Flicker OK OK OK OK OK Flicker OK OK Flicker Flicker OK OK OK
Lifetime Expectation
Power Factor & Total Harmonics Distortion
Power Efficiency
Technical Information Input Inrush Current
GE Lighting Solutions NELA Park – 1975 Noble Road East Cleveland, OH 44112 1-888-694-3533 (888-MY-GE-LED)
Input Inrush Current Input Voltage [Vrms] 120V
Peak Current Pulse [Apk] 1.5A
Pulse Duration (50% of Peak) [us] 110
Leakage Current
Input Ground Leakage Current Input Voltage [Vrms] 120V
Leakage Current (mA) 0.12
Product Dimensions
Current Programming Interface
GE Lighting Solutions NELA Park – 1975 Noble Road East Cleveland, OH 44112 1-888-694-3533 (888-MY-GE-LED)
Firstly set the Max Current to 1300mA and the Min Current to 850mA in the input box, then put the value to be programmed (between 850mA to 1300mA) into the input box for Current to Program, finally click the Send button to complete the programming of driver.
GE Lighting Solutions NELA Park – 1975 Noble Road East Cleveland, OH 44112 1-888-694-3533 (888-MY-GE-LED)