Preview only show first 10 pages with watermark. For full document please download

Indoor Rack Mount - Teledyne Paradise Datacom

   EMBED


Share

Transcript

Indoor Rack Mount GaN Solid State Power Amplifiers 7RU Rack Height FEATURES • • • • • • • • • Extremely High Power Density: to 1.5 kW C-Band; to 1.1 kW X-Band; to 800W Ku-Band. Hot Swap, n+1 Redundant Power Supply Power Factor Corrected Power Supply Modular (soft-fail) Architecture Removable fan assemblies Ethernet Port RF Output Sample Port Built-in 1:1 Redundancy Control Built-in Maintenance Switch Controller 7RU SSPA Chassis OPTIONS DESCRIPTION Teledyne Paradise Datacom’s 7RU Indoor, High Power Rack Mount series of SSPAs represent the industry’s highest power density and most reliable high power amplifier systems. The High Power Rack Mount SSPA employs a modular design, which allows quick and easy replacement in the event of a catastrophic failure of one of the SSPA components. These modular assemblies include: hot-swap SSPA modules, front and rear fan trays; and a rear panel controller card. These amplifiers are powered via a separate power supply chassis. The power supply is configured as a n+1 redundant, hot swappable, power supply comprised of up to four modules. The power supply is configured such that one module is redundant. In the event of a single power supply module failure, the HPA system will not fail. The power supply module can then be changed without ever taking the HPA out of service. Teledyne Paradise Datacom LLC 328 Innovation Blvd., Suite 100 State College, PA 16803 Tel: (814) 238-3450 Fax: (814) 238-3829 1 OF 8 www.paradisedata.com • • • • • • • Extended Frequency Band L-Band Input Reflected Power Monitor Phase Combined Systems Remote Control Panel RF Input Sample Port Rear Panel Air Intake and Exhaust SPECIFICATIONS • • • • SSPA Chassis housing: 7 Rack Units (RU) 19.0 X 12.22 X 30.0 in 483 X 310 X 762 mm 180 lbs / 82 kg 1RU Power Supply: 19.0 X 1.75 X 16.1 in 483 X 44 X 409 mm 29 lbs / 13 kg Gray powder coat finish Operating temperature: 0 to +50 °C Teledyne Paradise Datacom Ltd. 2&3 The Matchyns, London Road, Rivenhall End Witham, Essex CM8 3HA United Kingdom Tel: +44(0) 1376 515636 Fax: +44(0) 1376 533764 212888 REV E ECO 18228 Indoor Rack Mount GaN Solid State Power Amplifiers 7RU Rack Height Modular Design The 7RU Rack Mountable SSPA features a modular design which makes it easy to maintain. Four SSPA modules are phase combined inside the 7RU Rack Mountable SSPA to produce the amplifier’s total output power. Each of the SSPA modules is hot-swappable, allowing the unit to remain in service while a failed SSPA module is replaced. Hot-swappable SSPA Modules Front and rear fan assemblies are also field replaceable without taking the amplifier offline. The ability to remove the fan trays makes it easy to perform regular inspection and cleaning of the heatsink fins. Field Replaceable Fan Assemblies In addition, the Monitor and Control circuit card assembly and front display panel may be replaced while the amplifier is operating. 2 OF 8 212888 REV E ECO 18228 Indoor Rack Mount GaN Solid State Power Amplifiers 7RU Rack Height Specifications, C-Band SSPAs PARAMETER Frequency Range Output Power @: Saturation/PLinear 1 (Typical/Guaranteed minimum) Power Requirements Line Frequency Line Power (Voltage) (typical @ 220 VAC) Receive Band Noise Power Density NOTES LIMITS UNITS Frequency selection “L” Frequency selection “H” Frequency selection “C” 2 Frequency selection “A” Frequency selection “B” 2 Frequency selection “D” 4.400 to 5.000 5.715 to 5.790 5.750 to 6.670 5.850 to 6.425 5.850 to 6.725 6.425 to 7.025 GHz GHz GHz GHz GHz GHz HPAC711KARXXDXXG HPAC715KARXXDXXG Psat / PLinear 60.4 (1100) / 57.4 (550) 61.8 (1500) / 58.8 (750) dBm (W) dBm (W) HPAC711KARXXDXXG HPAC715KARXXDXXG 47 to 63 6000 / 5200 (180 to 265) 7200 / 6400 (180 to 265) Hz W (VAC) W (VAC) without filter -155 dBW / 4 kHz power factor corrected Note 1: PLinear = maximum output power at which third order intermodulation products < -25 dBc (for two tones separated by 5 MHz) or spectral regrowth on a single QPSK at 1.5 x symbol rate or OQPSK at 1.0 x symbol rate is < -30 dBc. Note 2: Output power decreases over the extended portion of the frequency range. Both Psat and PLinear de-rate by 1 dB from 5.85 to 5.75 GHz and from 6.425 to 6.725 GHz. Specifications, X-Band SSPAs PARAMETER Frequency Range Output Power @: Saturation/PLinear 1 (Typical/Guaranteed minimum) Power Requirements Line Frequency Line Power (Voltage) (typical @ 220 VAC) Receive Band Noise Power Density NOTES LIMITS UNITS Frequency selection “F” Frequency selection “D” Frequency selection “A” 7.10 to 7.40 7.70 to 8.40 7.90 to 8.40 GHz GHz GHz HPAX711KARXXDXXG Psat / PLinear 60.4 (1100) / 57.4 (550) dBm (W) HPAX711KARXXDXXG 47 to 63 6000 / 5200 (180 to 265) Hz W (VAC) without optional filter with optional filter -85 -155 dBW / 4 kHz dBW / 4 kHz power factor corrected Note 1: PLinear = maximum output power at which third order intermodulation products < -25 dBc (for two tones separated by 5 MHz) or spectral regrowth on a single QPSK at 1.5 x symbol rate or OQPSK at 1.0 x symbol rate is < -30 dBc. Specifications, Ku-Band SSPAs PARAMETER Frequency Range Output Power @: Saturation/PLinear 1 (Typical/Guaranteed minimum) Power Requirements Line Frequency Line Power (Voltage) (typical @ 220 VAC) Receive Band Noise Power Density2 NOTES LIMITS UNITS Frequency selection “F” Frequency selection “B” Frequency selection “A” Frequency selection “C” Frequency selection “D” 12.75 to 13.25 13.75 to 14.50 14.00 to 14.50 14.50 to 14.70 15.10 to 15.40 GHz GHz GHz GHz GHz HPAK7500ARXXDXXG HPAK2800ARXXDXXG Psat / PLinear 57.0 (500) / 54.0 (250) 59.0 (800) / 56.0 (400) dBm (W) dBm (W) .98 47 to 63 6400 / 4400 (180 to 265) 8400 / 6000 (180 to 265) Hz W (VAC) W (VAC) -155 dBW / 4 kHz power factor HPAK7500ARXXDXXG HPAK2800ARXXDXXG Note 1: PLinear = maximum output power at which third order intermodulation products < -25 dBc (for two tones separated by 5 MHz) or spectral regrowth on a single QPSK at 1.5 x symbol rate or OQPSK at 1.0 x symbol rate is < -30 dBc. Note 2: All Ku-Band SSPAs are fitted with a receive band reject bulkhead filter, standard. An optional pressure window is available. 3 OF 8 212888 REV E ECO 18228 Indoor Rack Mount GaN Solid State Power Amplifiers 7RU Rack Height Common Electrical Specifications PARAMETER NOTES LIMITS UNITS range full band full band (Extended C-Band) per 40 MHz 0 °C to +50 °C at constant temperature 0.1 dB resolution 55-75 ± 1.0 ± 1.5 ± 0.3 ± 1.0 ± 0.25 20 dB dB dB dB/40 MHz dB dB/24 hours dB At PLinear (Psat - 3 dB) -25 dBc AM/PM Conversion @ rated PLinear ≤ 1.0 °/dB Spurious Harmonics (SSPA only) @ rated PLinear @ rated PLinear -65 -50 dBc dBc All except Extended C-Band Extended C-Band 1.30:1 1.50:1 Gain Gain Flatness Gain Slope Gain Variation vs. Temperature Gain Stability Gain Adjustment Intermodulation Distortion (Two-tone, 5 MHz spacing) Input/Output VSWR Noise Figure at maximum gain 10 dB Group Delay (per 40 MHz segment) Linear Parabolic Ripple 0.01 0.003 1.0 ns/MHz ns/MHz2 ns p-p Transmit Band Noise Output Power Density TX Band -75 dBW/4 KHz Offset frequency from carrier 1 Hz 10 Hz 100 Hz 1 KHz 10 KHz 100 KHz 1 MHz -110 -120 -130 -135 -140 -140 -140 dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz Offset frequency from carrier 10 Hz 100 Hz 1 KHz 10 KHz 100 KHz 1 MHz -90 -100 -110 -120 -125 -130 dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz Range Accuracy Psat to (Psat - 20) ± 0.75 dB dBm Residual AM Noise, typical Residual Phase Noise, typical (SSPA only) True RF Power Detector Specifications are subject to change without notice. Receive Band Filter Option X-Band amplifiers may be ordered with an external receive band reject filter. 4 OF 8 212888 REV E ECO 18228 Indoor Rack Mount GaN Solid State Power Amplifiers 7RU Rack Height L-Band Operation Teledyne Paradise Datacom amplifiers are available with an integrated L-Band Block Up Converter. L-Band units utilize Teledyne Paradise Datacom’s proprietary zBUC technology. The addition of a zBUC® converter to the SSPA typically increases the gain by 2-4 dB. The advantages of zBUC technology include: • zBUC converter can detect and switch to an extenally supplied reference. • Optional internal high stability (10MHz) reference. • zBUC converter can lock to an externally supplied reference of 10 or 50 MHz. • zBUC converter can accept a wide range of external reference power (-10 to +5 dBm). Available Frequency Plans Band Frequency Band IF Input LO Frequency RF Output Gain Change C Standard C-Band 950 - 1525 MHz 4.900 GHz 5.850 - 6.425 GHz 0-4 dB C Extended C-Band 950 - 1825 MHz 4.900 GHz 5.850 - 6.725 GHz 0-4 dB C Palapa Band 950 - 1250 MHz 5.475 GHz 6.425 - 6.725 GHz 0-4 dB C Insat Band 950 - 1250 MHz 5.775 GHz 6.725 - 7.025 GHz 0-4 dB C Extended C-Band 2 950 - 1675 MHz 4.800 GHz 5.750 - 6.475 GHz 0-4 dB C Low C-Band 840 - 1000 MHz 4.250 GHz 5.090 - 5.250 GHz 0-4 dB X Standard X-Band 950 - 1450 MHz 6.950 GHz 7.900 - 8.400 GHz 0-2 dB Ku Standard Ku-Band 950 - 1450 MHz 13.050 GHz 14.00 - 14.50 GHz 0-2 dB Ku Extended Ku-Band 950 - 1700 MHz 12.800 GHz 13.75 - 14.50 GHz 0-2 dB Electrical Specifications for 7RU RM SSPA with ZBUC converter PARAMETER Gain Gain Flatness Gain Slope Gain Adjusted Range Gain Stability Phase Noise Spurious NOTES LIMITS UNITS Nominal setting full band (C-,X-,Ku-bands) per 40 MHz (C-,X-,Ku-bands) 75 ± 2.0 ± 0.5 20 60 - 80 57 - 77 ± 1.5 dB dB dB/40 MHz dB dB dB dB Typical C-Band Adj. Range Typical Ku-Band Adj. Range -40 to +60 °C Offset frequency from carrier 10 Hz 100 Hz 1 KHz 10 KHz 100 KHz 1 MHz Absolute max. -30 -60 -70 -80 -90 -90 C-band (typ.) -60 -80 -80 -85 -120 -125 In-Band Signal Related (C-/Ku-Band) (Extended C-Band) Close to Carrier Spurious (≤ 20 MHz) Local Oscillator X-band (typ.) -60 -75 -75 -100 -110 -122 Ku-band (typ.) -50 -65 -72 -90 -110 -120 -50 -40 -50 -30 dBc dBc dBc dBm dB Noise Figure At 75 dB gain setting 20 Input VSWR L-Band 1.5 : 1 Reference Accuracy (initial) Aging per day (after 30 days) Aging per year (after 30 days) Reference Stability over Temperature (-40 to +40 °C, ambient) ± 1 • 10-8 ± 1 • 10-9 ± 6 • 10-8 ± 1 • 10-8 Internal Reference Option 5 OF 8 dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz 212888 REV E ECO 18228 Indoor Rack Mount GaN Solid State Power Amplifiers 7RU Rack Height Mechanical Specifications PARAMETER Size HPA Chassis Power Supply Chassis NOTES LIMITS UNITS width X height X depth 19.0 X 10.47 X 30.0 483 X 266 X 762 inches mm 19.0 X 1.75 X 16.1 483 X 44 X 409 inches mm 180 (82) 29 (13) lbs. (kg) lbs. (kg) powder coat Gray width X height X depth Weight HPA Chassis Power Supply Chassis (1RU) Finish Environmental Specifications NOTES LIMITS UNITS Operating Temperature PARAMETER Ambient 0 to +50 °C Storage Temperature Ambient -20 to +75 °C Operating Relative Humidity Non-condensing 95 % Storage Relative Humidity Non-condensing 90 % Forced Convection Air Cooling Front Panel - Intake Rear Panel - Exhaust Cooling System Altitude No temperature de-rating up to 10,000 ft, (3000 m) De-rate maximum temperature by 2 °C per 1,000 ft (300 m) beyond 10,000 ft. Shock 50 g p-p, 11 msec pulses Vibration 3g rms 30 min. 5-2000 Hz 1RU N+1 Redundant Power Supply The addition of a separate, fully redundant power supply is an excellent means of obtaining the ultimate system reliability. The power supply is an N+1 redundant configuration, meaning that there is one more power supply module available than is required to operate the SSPA. Depending on the power requirements of the SSPA module, the power supply chassis is populated with two, three or four 2500W hot-swappable modules. A failure of one power supply module will not take the amplifier off the air. In addition, the power supply modules are removable from the front panel while in operation. There is never a need to remove the power supply chassis from the equipment rack. The power supply has a single phase, universal AC input rating from 180-265 VAC, 46-63 Hz. It is power factor corrected to 0.99. 6 OF 8 212888 REV E ECO 18228 Indoor Rack Mount GaN Solid State Power Amplifiers 7RU Rack Height Redundant and Phase Combined Systems Teledyne Paradise Datacom’s 7RU Rack Mount SSPAs can be configured in a variety of redundant and phase combined configurations. • • • • • • 1:1 Redundant System with Internal Redundancy Control 1:1 Redundant System with RCP2-1100 Redundant System Controller 1:1 Fixed Phase Combined System with FPRC-1100 Phase Combined System Controller 1:2 Redundant System with Internal Redundancy Control 1:2 Redundant System with RCP2-1200 Redundant System Controller 1:2 Fixed Phase Combined System with FPRC-1200 Phase Combined System Controller System Output Power Capacity Due to residual losses inherent in redundant system configurations (waveguide bends; switch and coupler losses), reduce the typical output power specification of a single amplifier by approximately 0.2 dB for 1:1 and by 0.4 dB for 1:2 systems. In phase combined systems, these same losses result in slightly less than the ideal addition of 3 dB to the output power of a single HPA unit. For 1:1 phase combined systems, the typical additive output power is approximately 2.70 dB above the output power of a single HPA. For 1:2 phase combined systems, the typical additive output power is approximately 2.50 dB above the output power of a single HPA. Actual system losses will vary based on the system options. System Controllers The RCP2/FPRC-1100/1200 system controller provides an extremely user friendly interface for complete monitor and control of the amplifier system. RCP2-1100 Redundant System Controller The front panel mimic display shows the on-line amplifiers and the switch positions. Fault lights are provided for easy identification of system status. All system monitor and control is available locally at the front panel LCD display, as well as remotely by the RS232, RS485, or Ethernet interface ports. Audible alarms and a full compliment of parallel I/O signal are available at the rear panel of the controller. 7 OF 8 212888 REV E ECO 18228 Indoor Rack Mount GaN Solid State Power Amplifiers 7RU Rack Height Part Number Configuration Matrix Power Level (Watts) C-Band 1100 (11K), 1500 (15K) X-Band 1100 (11K) Ku-Band 500, 800 Band S-Band C-Band X-Band Ku-Band S C X K Rack Height 7RU 7 R S T Y Z Standalone Unit or System Package Standalone amplifier System with Cabinet, Top Mounted Waveguide Switching System without Cabinet, Top Mounted Waveguide Switching System with Cabinet, Rear Mounted Waveguide Switching System without Cabinet, Rear Mounted Waveguide Switching Block Up Converter M Internal Reference BUC P External Reference BUC X No BUC P L 1 MODEL: 1 Available with optional BUC X A1 B C1 D1 E F Standalone Unit or System Configuration Standalone amplifier 1:1 System, Input Switching, Internal Control 1:1 System, Input Splitter, Internal Control 1:2 System, Input Switching, RCP2-12002 1:2 System, Input Switching, Internal Control 1:2 Phase Combined System, Input Splitter, FPRC-12002 1:1 System, Input Splitter, RCP2-11002 G 1:1 Phase Combined system, Input Splitter, FPRC-11002 1 2 Not available with package options Y and Z HPA C 7 1 1 K A R M X X X P G Frequency Sub Band C-Band X-Band 1 5.850 to 6.425 GHz A 7.90 to 8.40 GHz 5.850 to 6.725 GHz D 7.70 to 8.40 GHz 5.750 to 6.670 GHz F 7.10 to 7.40 GHz 6.425 to 7.025 GHz Ku-Band 5.715 to 5.790 GHz 1 A 14.00 to 14.50 GHz 4.400 to 5.000 GHz B1 13.75 to 14.50 GHz F1 12.75 to 13.25 GHz G1 14.75 to 15.25 GHz A1 B1 C D1 H L Configuration Modifier 3 Standard (N+1 Power Supply) N+1 P.S. + Rear Exhaust Adapters GaN Device Designator G GaN Device Configuration Modifier 2 X Standard R1 V 1 Rx Band Reject Filter Reflected Power Monitor X-Band units only Configuration Modifier 1 X Standard S Input Sample Port Example - A standalone 1100W GaN C-Band 7RU Rack Mount GaN SSPA with standard N+1 external power supply and an optional internal reference block up converter is part number: HPAC711KARMXXXPG. Use and Disclosure of Data H1 1:1 System, Input Switching, RCP2-11002 J 1:2 Phase Combined system, Input splitter, Internal Control The information contained herein is classified as EAR99 under the U.S. Export Administration Regulations. Export, re-export or diversion contrary to U.S. law is prohibited. Switched input with external reference BUC requires reference distribution box. Standard location for controller is directly above HPA1. Specifications are subject to change without notice. 8 OF 8 212888 REV E ECO 18228