Preview only show first 10 pages with watermark. For full document please download

Indoor Unit - Energy Conscious

   EMBED


Share

Transcript

Indoor unit R410A 6CIM0-01B (Replaces 6CIM0-01A) Indoor unit Introduction Preface New era brings the more sophisticated and advanced buildings which in turn demands for specialized and optimized direct expansion air conditioning systems. Also energy efficiency, low noise and low maintenance are the features which are essential for these systems. As a part of vertical integration LG makes all the key components in house, which gives us an edge to LG to make better and latest technology products with best quality in optimized time. systems are equipped with inverter technology and R410A refrigerant which is perfect solution to various installation locations. This Engineering product data book incorporates information about the product itself, and installation, designing for system. The comprehensive study of this book will improve your knowledge about the system and its application in detail. LG Electronics Inc. Air Conditioning & Energy Solution Company Indoor unit General information 1. Model line up 2. Nomenclature 3. Appearance Indoor unit 1. Model line up Chassis SB 2.64 (9) AMNW09GDBL0 [LMN096HVT] 5.28 (18) AMNW12GDBL0 [LMN126HVT] Wall mounted AMNW18GDCL0 [LMN186HVT] SC SB AMNW09GDBR0 [LMAN096HVT] AMNW12GDBR0 [LMAN126HVT] ARTCOOL Mirror AMNW18GDCR0 [LMAN186HVT] SC AMNW12GTRA0 [LMCN125HV] TR Ceiling cassette AMNW18GTQA0 [LMCN185HV] TQ B1 Ceiling concealed duct Low static pressure (Slim) B2 AMNW09GB1A0 [LMDN095HV] AMNW12GB1A0 [LMDN125HV] AMNW18GB2A0 [LMDN185HV] Heat pump 60Hz/R410A _ 1 General information Category Model names Capacity, kW(kBtu/h Class) 3.52 (12) Indoor unit General information 2. Nomenclature 2.1 Global model names AMN W 09 G D B L 0 Serial number Function A : Basic, L : Plasma (Wall mounted) C : Plasma(ceiling cassette) ART COOL(Mirror) type front panel color R : Mirror Chassis name Indoor unit type D : Wall Mounted, ART COOL Mirror T : Ceiling cassette, B : Ceiling concealed duct Electrical rating G: 208/230V, 1Ø, 60Hz Cooling/heating capacity Ex) 9,000 Btu/h Class → '09', 18,000 Btu/h Class → '18' Model type W : DC Inverter heat pump Indicates that this is multi system indoor unit using R410A 2 _ Heat pump 60Hz/R410A Indoor unit 3. Appearance • Wall Mounted General information 3.1 Indoor units • ART COOL Mirror AMNW09GDBR0 [LMAN096HVT] AMNW12GDBR0 [LMAN126HVT] AMNW18GDCR0 [LMAN186HVT] AMNW09GDBL0 [LMN096HVT] AMNW12GDBL0 [LMN126HVT] AMNW18GDCL0 [LMN186HVT] • Ceiling Concealed Duct – Low static pressure AMNW09GB1A0 [LMDN095HV] AMNW12GB1A0 [LMDN125HV] AMNW18GB2A0 [LMDN185HV] • Ceiling Cassette 4-way AMNW12GTRA0 [LMCN125HV] AMNW18GTQA0 [LMCN185HV] 3.2 Control system(standard) These controllers will be provided with the respective indoor units. Type Individual controller Simple wired remote controller Applicable model Ceiling concealed duct PQRCVCL0QW Wireless remote controller Ceiling cassette PQWRHDF0 Wireless remote controller Wall mounted ART COOL Mirror Heat pump 60Hz/R410A _ 3 Indoor unit 1. Wall Mounted 2. ART COOL Mirror 3. Ceiling cassette 4-way 4. Ceiling concealed duct - Low static pressure Indoor unit Wall Mounted 1. List of functions 2. Specifications 3. Dimensions 4. Piping diagrams 5. Wiring Diagrams 6. Capacity Tables 7. Air flow and temperature distributions (reference data) 8. Sound levels 9. Controller 10. Installation Indoor unit 1. List of functions Category Air flow Air purifying Reliability Convenience Individual controller Network Solution Special function kit Others Air supply outlet Airflow direction control (left & right) Airflow direction control (up & down) Auto swing (left & right) Auto swing (up & down) Airflow steps (fan/cool/heat) Chaos wind(auto wind) Jet cool/heat Swirl wind Triple filter (Deodorizing) Plasma air purifier Allergy Safe filter Long-life prefilter (washable / anti-fungus) Drain pump E.S.P. control Electric heater High ceiling operation Auto Elevation Grille Hot start Self diagnosis Soft dry operation Auto changeover Auto cleaning Auto operation(artificial intelligence) Auto Restart Child lock* Forced operation Group control Sleep mode Timer(on/off) Timer(weekly)* Two thermistor control* Wired remote controller Deluxe wired remote controller Simple wired remote controller Simple Wired remote controller(for hotel use) Wireless remote controller General central controller (Non LGAP) Network Solution(LGAP) Dry contact PI 485(for Indoor Unit) Zone controller CTI(Communication transfer interface) Electronic thermostat Remote temperature sensor Telecom shelter controller AMNW09GDBL0 [LMN096HVT] AMNW12GDBL0 [LMN126HVT] AMNW18GDCL0 [LMN186HVT] 1 Auto Auto O O 5/6/6 O O/O X X O X O X X X X X O O O X O O O O O X O O O O PQRCVSL0 / PQRCVSL0QW X PQRCVCL0Q / PQRCVCL0QW X O X O PQDSA(1)/PQDSB(1) / PQDSBC / PQDSBNGCM1 X X X X X X Note : 1. * : These functions need to connect the wired remote controller. O : Applied, X : Not applied Accessory model name : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package. Wall mounted _ 1 Indoor Units Installation Functions Indoor unit 2. Specifications AMNW09GDBL0 [LMN096HVT] AMNW12GDBL0 [LMN126HVT] AMNW18GDCL0 [LMN186HVT] V, Ø, Hz 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 Nominal kW Class 2.6 3.5 5.3 Nominal Btu/h Class 9,000 12,000 18,000 - White White White WxHxD mm 895 × 289 × 210 895 × 289 × 210 1,030 × 325 × 250 WxHxD inch 35-1/4 x 11-3/8 x 8-9/32 35-1/4 x 11-3/8 x 8-9/32 40-9/16 x 12-25/32 x 9-27/32 kg (lbs) 10.0 (22.1) 10.0 (22.1) 14.5 (32.0) - (2 x 16 x 23) x 1 (2 x 16 x 23) x 1 (3 x 18 x 22) x 1 m (ft ) 0.22 (2.37) 0.22 (2.37) 0.29 (3.07) - Cross Flow Fan Cross Flow Fan Cross Flow Fan H/M/L m /min 7.0 / 6.5 / 6.0 9.5 / 9.0 / 8.5 16.2 / 14.2 / 12.3 H/M/L ft /min 247 / 230 / 212 335 / 318 / 300 572 / 501 / 434 - BLDC BLDC BLDC W x No. 14.4 x 1 14.4 x 1 76.0 x 1 A 0.20 0.20 0.30 Model Name Power Supply Capacity Casing Color Dimensions Body Net Weight Body Heat Exchanger (Row x Column x Fins per inch) x No. Face Area 2 Type Indoor Units Fan Air Flow Rate Type Fan Motor Output Running Current 2 3 3 Sound Pressure Level H/M/L dB(A) 33 / 30 / 27 39 / 36 / 31 37 / 33 / 28 Sound Power Level Cooling dB(A) - - - Liquid mm(inch) 6.35 (1/4) 6.35 (1/4) 6.35 (1/4) Gas mm(inch) 9.52 (3/8) 9.52 (3/8) 12.7 (1/2) Drain (O.D. / I.D.) mm(inch) 21.5(27/32) / 16.0(5/8) 21.5(27/32) / 16.0(5/8) 21.5(27/32) / 16.0(5/8) Piping Connections Safety Devices Power and Communication Cable (included Earth) - Fuse Fuse Fuse - Thermal Protector for Fan Motor Thermal Protector for Fan Motor Thermal Protector for Fan Motor No. x AWG 4C x 18 4C x 18 4C x 18 Note : 1. Wiring cable size must comply with the applicable local and national code. 2. Due to our policy of innovation some specifications may be changed without notification. 3. Sound Level Values are measured at Anechoic chamber. Therefore, these values can be increased owing to ambient conditions during opration. 4. Acceptable operating voltage: 187V-253V 2 _ Wall mounted Wall mounted _ 3 341(13-15/32) 37(1-15/32) 422(16-5/8) 675(26-9/16) 327(12-7/8) 790(31-3/32) 895(35-1/4) 323(12-23/32) 70(2-3/4) 128(5-1/32) 45(1-25/32) 210(8-9/32) 205(8-1/16) Air suction grille Knockout hole Installation plate 4 5 Remark CHASSIS CODE: SB 3. The Unit is powered from the outdoor unit. Therefore power cable should be connected with the outdoor unit. 2. Unit shall be grounded in accordance with the local regulations or applicable national codes. 1. Unit should be installed in compliance with the installation manual in the product box. Note Display & signal receiver 3 76, Seongsan-dong, Changwon City, Gyeongnam, 641-713, Korea [Unit : mm(inch)] 50(1-31/32) Front panel 2 Part Name AMNW09GDBL0[LMN096HVT] AMNW12GDBL0[LMN126HVT] 1 No. Indoor Units 264(10-13/32) 285(11-7/32) WALL MOUNTED Indoor unit 3. Dimensions 69(2-23/32) 105(4-1/8) 460(18-1/8) Measuring Tape Hanger Measuring Tape Installation Plate Place a level on raised tab 56(2-7/32) 570(22-7/16) 210(8-9/32) 207(8-5/32) Right rear piping Ø 70(2-3/4) 5 325(12-25/32) 4 _ Wall mounted Left rear piping Ø70(2-3/4) Unit Outline 1030(40-9/16) 250(9-27/32) Display & signal receiver Air suction grille Knockout hole Installation plate 3 4 5 Note Front panel 2 Part Name Remark 76, Seongsan-dong, Changwon City, Gyeongnam, 641-713, Korea CHASSIS CODE: SC 3. The Unit is powered from the outdoor unit. Therefore power cable should be connected with the outdoor unit. 2. Unit shall be grounded in accordance with the local regulations or applicable national codes. 1. Unit should be installed in compliance with the installation manual in the product box. [Unit : mm(inch)] 4 WALL MOUNTED AMNW18GDCL0[LMN186HVT] 1 No. Indoor Units Indoor unit 3. Dimensions Indoor unit Cooling Gas pipe connection port (flare connection) Heat Exchanger Cross Flow Fan Thermistor for Evaporator Outlet Temperature Liquid pipe connection port (flare connection) n Refrigerant pipe connection port diameters Unit : mm(inch) Model Gas Liquid AMNW09GDBL0 [LMN096HVT] AMNW12GDBL0 [LMN126HVT] Ø9.52(3/8) Ø6.35(1/4) AMNW18GDCL0 [LMN186HVT] Ø12.7(1/2) Ø6.35(1/4) Description Thermistor for Indoor Air Temperature Thermistor for Evaporator Inlet Temperature PCB Connector CN_TH1 Thermistor for Evaporator Outlet Temperature CN_TH2 Thermistor for Evaporator middle temperature CN_TH3 Notes : Description is expressed based on Cooling mode. Wall mounted _ 5 Indoor Units Thermistor for Evaporator Inlet Temperature M Thermistor for Indoor Air Temperature Heating Thermistor for Evaporator middle temperature 4. Piping diagrams Indoor unit 5. Wiring diagrams Indoor Units Models : AMNW09GDBL0 [LMN096HVT] / AMNW12GDBL0 [LMN126HVT] Models : AMNW18GDCL0 [LMN186HVT] 6 _ Wall mounted Indoor unit 6. Capacity Tables n Cooling Capacity Outdoor Unit Size air temp. (kBtu/h(kW)) °F DB 9.0 (2.64) 12 (3.52) Indoor Air Temp. °F DB/ °F WB 68.0 / 57.2 71.6 / 60.8 77.0 / 64.4 TC SHC TC SHC TC 8.70 8.40 7.90 7.70 7.40 7.20 7.00 11.60 11.20 10.50 10.30 9.80 9.50 9.30 17.40 16.80 15.70 15.30 14.70 14.30 13.90 7.34 6.80 6.15 6.10 6.04 6.16 6.30 10.35 9.60 8.63 8.72 8.51 8.63 8.86 15.00 13.94 12.47 12.57 12.28 12.52 12.82 9.20 8.90 8.40 8.20 7.90 7.70 7.50 12.30 11.90 11.20 11.00 10.50 10.30 10.00 18.50 17.80 16.90 16.40 15.80 15.40 15.00 7.54 6.99 6.20 6.14 6.09 6.26 6.47 10.66 9.83 8.74 8.75 8.60 8.86 9.13 15.49 14.27 12.75 12.66 12.47 12.83 13.26 9.80 9.40 9.00 8.80 8.40 8.20 8.00 13.00 12.60 12.00 11.70 11.20 11.00 10.70 19.60 18.90 18.00 17.60 16.80 16.40 16.00 SHC 7.81 7.16 6.32 6.24 6.19 6.42 6.69 11.02 10.10 8.90 8.79 8.73 9.05 9.44 16.01 14.70 12.93 12.78 12.65 13.10 13.66 80.6 / 66.2 86.0 / 71.6 89.6 / 75.2 TC SHC TC SHC TC SHC 10.20 9.80 9.30 9.00 8.80 8.60 8.40 13.50 13.10 12.50 12.00 11.70 11.50 11.20 20.30 19.60 18.70 18.00 17.60 17.20 16.80 8.03 7.32 6.37 6.32 6.29 6.53 6.84 11.27 10.30 9.00 8.90 8.82 9.19 9.63 16.35 14.95 13.07 12.90 12.83 13.34 13.97 10.80 10.50 10.00 9.80 9.50 9.30 9.10 14.50 14.00 13.40 13.10 12.70 12.40 12.10 21.70 21.00 20.10 19.70 19.00 18.50 18.20 7.59 7.10 6.39 6.39 6.63 6.79 6.98 10.72 10.00 9.02 9.03 9.32 9.53 9.85 15.57 14.49 13.12 13.12 13.53 13.79 14.28 11.40 11.00 10.60 10.40 10.00 9.80 9.60 15.20 14.70 14.10 13.80 13.40 13.10 12.80 22.80 22.10 21.20 20.80 20.10 19.70 19.20 7.25 6.89 6.44 6.46 6.71 6.97 7.12 10.22 9.73 9.09 9.10 9.67 9.83 10.02 12.30 11.73 10.94 10.97 11.69 11.86 12.05 Notes: 1. Capacities are based on the following conditions. Corresponding refrigerant piping length : 25ft Level difference : 0ft 2. TC : Total Capacity(kBtu/h) SHC: Sensible Heat Capacity(kBtu/h) Wall mounted _ 7 Indoor Units 18 (5.28) 68.0 77.0 89.6 95.0 104.0 109.4 114.8 68.0 77.0 89.6 95.0 104.0 109.4 114.8 68.0 77.0 89.6 95.0 104.0 109.4 114.8 Cooling Capacity Indoor unit 6. Capacity Tables n Heating Capacity Unit Size (kBtu/h(kW)) 9.0 (2.64) Indoor Units 12 (3.52) 18 (5.28) Indoor air temp. °F DB 60.8 64.4 68.0 70.0 71.6 75.2 60.8 64.4 68.0 70.0 71.6 75.2 60.8 64.4 68.0 70.0 71.6 75.2 Heating capacity Outdoor Air Temp. °F WB 5 14 23 32 TC TC TC 6.0 6.0 5.9 5.9 5.8 5.5 8.0 7.9 7.9 7.8 7.7 7.4 12.0 11.9 11.8 11.7 11.6 11.0 7.4 7.3 7.3 7.2 7.2 6.9 9.8 9.7 9.7 9.6 9.5 9.2 14.8 14.6 14.6 14.4 14.3 13.7 8.5 8.4 8.4 8.3 8.2 8.0 11.3 11.2 11.2 11.1 11.0 10.6 16.9 16.7 16.7 16.6 16.4 16.0 Notes: 1. Capacities are based on the following conditions. Corresponding refrigerant piping length : 25ft Level difference : 0ft 2. TC : Total Capacity(kBtu/h) 8 _ Wall mounted 43 50 59 TC TC TC TC 9.5 9.4 9.4 9.3 9.2 9.0 12.6 12.5 12.5 12.4 12.3 12.0 18.9 18.8 18.7 18.5 18.4 17.9 10.5 10.4 10.4 10.4 10.3 10.0 14.0 13.9 13.9 13.8 13.7 13.4 20.9 20.8 20.7 20.8 20.5 20.0 10.9 10.9 10.9 10.8 10.7 10.5 14.6 14.5 14.5 14.4 14.3 13.9 21.9 21.8 21.7 21.6 21.4 20.9 11.0 10.9 10.9 10.8 10.8 10.5 14.6 14.5 14.5 14.4 14.3 14.0 22.0 21.8 21.8 21.6 21.5 20.9 Indoor unit 7. Air flow and temperature distributions (reference data) Model : AMNW09GDBL0 [LMN096HVT] Cooling Heating Discharge angle : 40° Discharge angle : 50° Air velocity [ft/s] Air velocity [ft/s] 9ft 9ft 7ft 7ft 6.6 4.9 4.9 3ft 3ft 3.3 1.6 3.3 1.6 0ft 16ft 13ft 10ft 7ft 3ft 0ft 0ft 16ft Temperature [°F] 13ft 10ft 7ft 3ft 0ft Temperature [°F] 9ft 9ft 7ft 91 64 70 75 86 3ft 68 3ft 81 72 75 16ft 13ft 10ft 0ft 7ft 3ft 0ft 0ft 16ft 13ft 10ft 7ft 3ft 0ft Model : AMNW12GDBL0 [LMN126HVT] Cooling Heating Discharge angle : 40° Discharge angle : 50° Air velocity [ft/s] Air velocity [ft/s] 9ft 9ft 7ft 7ft 6.6 6.6 3ft 3ft 4.9 1.6 3.3 3.3 1.6 4.9 0ft 16ft 13ft 10ft 7ft 3ft 0ft 16ft 0ft 13ft 10ft 7ft 3ft 0ft Temperature [°F] Temperature [°F] 9ft 9ft 7ft 7ft 91 64 70 86 3ft 68 3ft 81 75 16ft 13ft 10ft 75 72 7ft 0ft 3ft 0ft 0ft 16ft 13ft 10ft 7ft 3ft 0ft Wall mounted _ 9 Indoor Units 7ft Indoor unit 7. Air flow and temperature distributions (reference data) Model : AMNW18GDCL0 [LMN186HVT] Cooling Heating Discharge angle : 40° Discharge angle : 50° Air velocity [ft/s] Air velocity [ft/s] 8.2 1.6 26ft 23ft 20ft 16ft 13ft 10ft 9ft 9ft 7ft 7ft 3ft 4.9 3.3 7ft 3.3 1.6 3ft 0ft 0ft 3ft 6.6 26ft 23ft 20ft 16ft 13ft 10ft 7ft 4.9 3ft 0ft Temperature [°F] Indoor Units Temperature [°F] 9ft 9ft 7ft 7ft 91 64 68 23ft 20ft 10 _ Wall mounted 16ft 13ft 3ft 10ft 7ft 81 75 3ft 0ft 0ft 26ft 23ft 20ft 16ft 3ft 86 70 72 75 26ft 0ft 13ft 10ft 7ft 3ft 0ft 0ft Indoor unit 8. Sound levels Overall Notes: - Sound measured at 3.3ft away from the center of the unit. - Data is valid at free field condition. - Data is valid at nominal operation condition. - Reference accoustic pressure 0dB=20μPa. - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed. - The operating conditions are assumed to be standard. 3.3ft 2.6ft Microphone Sound Levels [dB(A)] H M L 33 30 27 39 36 31 37 33 28 Model AMNW09GDBL0[LMN096HVT] AMNW12GDBL0[LMN126HVT] AMNW18GDCL0[LMN186HVT] AMNW12GDBL0 [LMN126HVT] AMNW18GDCL0 [LMN186HVT] 80 70 70 70 NC-65 60 NC-60 NC-55 50 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 Approximate Hearing Threshold NC-60 NC-55 50 NC-50 NC-15 125 250 500 1000 2000 4000 Octave Band CenterFrequency (Hz) 8000 NC-45 40 NC-40 NC-35 30 NC-30 NC-65 60 NC-60 NC-55 50 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 NC-20 Approximate Hearing Threshold NC-15 10 63 NC-25 20 Approximate Hearing Threshold NC-20 10 63 NC-65 60 Octave Band Sound Pressure Level (0dB = 20μPa ) 80 Octave Band Sound Pressure Level (0dB = 20μPa ) Octave Band Sound Pressure Level (0dB = 20μPa ) AMNW09GDBL0 [LMN096HVT] 80 125 250 500 1000 2000 4000 Octave Band CenterFrequency (Hz) 8000 NC-20 NC-15 10 63 125 250 500 1000 2000 4000 8000 Octave Band Center Frequency (Hz) Wall mounted _ 11 Indoor Units Sound pressure level Indoor unit 9. Controller Wireless remote control Control panel a Display screen Display screen Description F Plasma button*:Plasmaster filter purifies the air by removing mites, micro dust and pet fur. Plasmaster Ionizer sterilize the aerial bacteria and other harmful substances. l Sleep mode auto button*: Sets the sleep mode auto operation. e Temperature adjustment buttons: Adjusts the room temperature when cooling and heating. d - On/Off button: Turns the power on/off. Indoor Units fan speed button: Adjusts the fan g 7 v Indoor speed. Control panel f h Operation mode selection button*: A C Selects the operation mode. Cooling operation (A) / Auto operation or D B auto changeover (C) / Dehumidifying operE ation (D) / Heating operation (B) / Air circulation (E) N i j H I k S m nz c b u J G P Jet cooling/heating button*: Warms up or cools down the indoor temperature within a short period of time. Air flow direction button: Adjusts the air flow direction vertically or horizontally. Temperature display button: Displays the room temperature. Press key and hold it for longer than 5 second. Display change °C/°F Timer button: Sets the current time and the start / end time. Navigation and functions button*: Adjusts the time and sets the special functions. J: Auto clean / G: Operates energy saving cooling / P: Adjusts the brightness of the indoor unit display p - Set/clear button: Sets or cancels functions. r - Reset button: Resets the air conditioner settings. * Some functions may not be supported, depending on the model. 12 _ Wall mounted Indoor unit 10. Installation • Please read the instruction sheets completely before installing the product. • When the power cord is damaged, replacement work shall be performed by authorized personnel only. • Installation work must be performed in accordance with the national wiring standards by authorized personal only. Installation plate Sleeve Bushing-Sleeve Putty(Gum Type Sealant) Bend the pipe as closely on the wall as possible, but be careful that it doesn't break. Indoor Units Vinyl tape (Wide) • Apply after carrying out a drainage test. • To carry out the drainage test, remove the air filters and pour water into the heat exchanger. Saddle 10.1 Accessories The following accessories are included with your unit. 1) Standard accessories 1. Type "A" screw 2. Installation plate Name Installation panel 3. Type "B" screw 4. Remote control holder Securing screws (Other) Type "A" screw Type "B" screw SB Chassis Diagram • Owner's manual • Installation manual M4 x 12L SC Chassis Wall mounted _ 13 14 _ Wall mounted 133(5 1/4) Left rear piping Ø70(Ø2 3/4) Installation plate Indoor Units Unit : mm(inch) Right rear piping 95(3 3/4) Ø70(Ø2 3/4) Indoor unit 10. Installation 2) Installation plate dimensions Type 1: SB Chassis 69(2 23/32) Left rear piping Ø70(Ø2-3/4) 105(4 1/8) 460(18 1/8) Measuring Tape Hanger Measuring Tape Installation Plate Indoor Units Unit Outline Place a level on raised tab 570(22 7/16) Unit : mm(inch) 207(8 5/32) 56(2 7/32) Right rear piping Ø70(Ø2-3/4) Indoor unit 10. Installation Type 2: SC Chassis CAUTION • Use only those accessories (Standard or optional) which have designated specilications Wall mounted _ 15 Indoor unit 10. Installation More than 100(3-15/16) More than 200(7-7/8) Indoor Units More than 100(3-15/16) Place a level on raised tab Unit Outline Ø70 (Ø2 3/4) Ø70 (Ø2 3/4) Installation Plate 133(5 1/4) 175(6 7/8) Recommended height 2000(78-3/4) 95(3 3/4) Right rear piping ① There should not be any heat or steam near the unit. ② Select a place where there are no obstacles around of the unit. ③ Make sure that condensation drainage can be conveniently routed away. ④ Do not install near a doorway. ⑤ Use a metal detector to locate studs to prevent unnecessary damage to the wall. ② Measure the wall and mark the centerline. It is also important to use caution concerning the location of the installation plate. Routing of the wiring to power outlets is through the walls typically. Drilling the hole through the wall for piping connections must be done safely. Left rear piping 10.2 Selection of the best location 217(8 17/32) Unit : mm(inch) Unit : mm(inch) Note : Remove obstructions to prevent blockage of airflow path 10.4 Before piping work CAUTION • Installation Information. For right piping. Follow the instruction given below. 10.3 Fixing installation plate The wall you select should be strong and solid enough to prevent vibration ① Mount the installation plate on the wall with type "A" screws. If mounting the unit on a concrete wall, use anchor bolts. • Mount the installation plate horizontally by aligning the centerline using Horizontal meter . Installation Plate Type "A" Screws Chassis Hook 16 _ Wall mounted Good case • Press on the upper side of clamp and unfold the tubing to downward slowly. Indoor unit 10. Installation Wrong method 1) Installation of Indoor Unit • Following bending type from left to right may cause damage to the tubing. ① Hook the indoor unit onto the upper portion of the installation plate.( engage the three hooks at the top of the indoor unit with the upper edge of the installation plate) Ensure that the hooks are properly seated on the installation plate by moving it left and right 1 2 Installation plate 10.5 Connecting the piping ① Pull the screw cap at the bottom of the indoor unit ② Remove the chassis cover from the unit by loosing 2 screws Tubing Holder Chassis Cover ③ Pull back the tubing holder. ④ Remove pipe port cover and positioning the tubing Indoor unit back side view Right Downwards Tubing holder Left Backwards Wall mounted _ 17 Indoor Units ② Unlock the tubing holder from the chassis and mount between the chassis and installation plate in order to separate the bottom side of the indoor unit from the wall Indoor unit 10. Installation Wiring and Piping Connection ① Insert the connecting cable through the bottom side of indoor unit and connect the cable (You can see detail contents in 'Connecting the cables' section) Tape Connecting cable Drain hose Indoor Units View Connecting pipe Terminal block Remote controller cable Connecting cable Cable retainer ② Secure the cable onto the control board with the cable retainer. ③ Tape the tubing pipe, drain hose. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the upper side can cause overflow from the drain pan through the inside of the unit. 2) Connecting the installation pipe and drain hose to the indoor unit. ① Align the center of the pipes and sufficiently tighten the flare nut by hand ② Tighten the flare nut with a wrench Indoor unit tubing Flare nut Spanner (fixed) Flare nut Connection pipe Torque wrench CAUTION If the drain hose is routed inside the room insulate the hose with an insulation material* so that dripping from sweating (condensation) will not damage furniture or floors. Pipings ③ When needed to extend the drain hose of indoor unit, assembly the drain pipe as shown on the drawing * Foamed polyethylene or equivalent is recommended. Drain pipe Indoor unit drain hose Vinyl tape(narrow) Adhesive Tape Connecting cable Drain hose Connecting pipe Drain hose 18 _ Wall mounted Indoor unit 10. Installation 3) Wrap the insulation material around the connecting portion. ① Overlap the connection pipe heat insulation and the indoor unit pipe heat insulation material. Bind them together with vinyl tape so that there may be no gap. ② Wrap the area which accommodates the rear piping housing section with vinyl tape. Plastic bands Insulation material 4) Finishing the indoor unit installation ① Mount the tubing holder in the original positon. ② Ensure that the hooks are properly seated on the installation plate by moving it left and right. ③ Press the lower left and right sides of the unit against the installation plate until the hooks engage into their slots (clicking sound). ④ Finish the assembly by screwing the unit to the installation plate by using two pieces of type "C" screws. And assemble a chassis cover. Indoor unit pipe Connection pipe Type 'C' screw Pipe Vinyl tape(narrow) Before operating the units, detach two nitto tapes from the plasma filter. ③ Bundle the piping and drain hose together by wrapping them with cloth tape over the range within which they fit into the rear piping housing section. Wrap with vinyl tape Pipe Vinyl tape(wide) Drain hose Plasma Filter Wall mounted _ 19 Indoor Units Wrap with vinyl tape Vinyl tape (wide) Indoor unit 10. Installation 10.6 Checking the Drainage 2) Drain piping 1) To check the drainage. ① The drain hose should point downward for easy drain flow. ① Pour a glass of water on the evaporator. ② Ensure the water flows through the drain hose of the indoor unit without any leakage and goes out the drain exit. Downward slope Connecting area drain hose ② Do not make drain piping like the following. Leakage checking Drain pan Accumulated drain water Air Indoor Units Do not raise Drain hose Leakage checking Water leakage Water leakage Tip of drain hose dipped in water Water leakage 20 _ Wall mounted Ditch Waving Less than 50mm gap Indoor unit ART COOL Mirror 1. List of functions 2. Specifications 3. Dimensions 4. Piping diagrams 5. Wiring Diagrams 6. Capacity Tables 7. Air flow and temperature distributions (reference data) 8. Sound levels 9. Controller 10. Installation Indoor unit 1. List of functions Category Air flow Air purifying Reliability Convenience Individual controller Network Solution Special function kit Others AMNW09GDBR0 [LMAN096HVT] AMNW12GDBR0 [LMAN126HVT] AMNW18GDCR0 [LMAN186HVT] Air supply outlet Airflow direction control (left & right) Airflow direction control (up & down) Auto swing (left & right) Auto swing (up & down) Airflow steps (fan/cool/heat) Chaos wind(auto wind) Jet cool/heat Swirl wind Triple filter (Deodorizing) Plasma air purifier Allergy Safe filter Long-life prefilter (washable / anti-fungus) Drain pump E.S.P. control Electric heater High ceiling operation Auto Elevation Grille Hot start Self diagnosis Soft dry operation Auto changeover Auto cleaning Auto operation(artificial intelligence) Auto Restart Child lock* Forced operation Group control Sleep mode Timer(on/off) Timer(weekly)* Two thermistor control* Wired remote controller Deluxe wired remote controller Simple wired remote controller Simple Wired remote controller(for hotel use) Wireless remote controller General central controller (Non LGAP) Network Solution(LGAP) Dry contact PI 485(for Indoor Unit) Zone controller CTI(Communication transfer interface) Electronic thermostat Remote temperature sensor Telecom shelter controller 1 Auto Auto O O 5/6/6 O O/O X X O X O X X X X X O O O X O O O O O X O O O O PQRCVSL0 / PQRCVSL0QW X PQRCVCL0Q / PQRCVCL0QW X O X O PQDSA(1)/PQDSB(1) / PQDSBC / PQDSBNGCM1 X X X X X X Note 1. * : These functions need to connect the wired remote controller. O : Applied X : Not applied Accessory model name : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package. ART COOL Mirror _ 1 Indoor Units Installation Functions Indoor unit 2. Specifications AMNW09GDBR0 [LMAN096HVT] AMNW12GDBR0 [LMAN126HVT] AMNW18GDCR0 [LMAN186HVT] V, Ø, Hz 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 Nominal kW Class 2.6 3.5 5.3 Nominal Btu/h Class 9,000 12,000 18,000 - Grace Dark Gray Grace Dark Gray White WxHxD mm 895 × 289 × 205 895 × 289 × 205 1,030 × 325 × 245 WxHxD inch 35-1/4 x 11-3/8 x 8-1/16 35-1/4 x 11-3/8 x 8-1/16 40-9/16 x 12-25/32 x 9-21/32 kg (lbs) 11.0 (24.3) 11.0 (24.3) 15.5 (34.2) - (2 x 16 x 23) x 1 (2 x 16 x 23) x 1 (3 x 18 x 22) x 1 m (ft ) 0.22 (2.37) 0.22 (2.37) 0.29 (3.07) - Cross Flow Fan Cross Flow Fan Cross Flow Fan H/M/L m /min 7.0 / 6.5 / 6.0 9.5 / 9.0 / 8.5 16.2 / 14.2 / 12.3 H/M/L ft /min 247 / 230 / 212 335 / 318 / 300 572 / 501 / 434 - BLDC BLDC BLDC W x No. 14.4 x 1 14.4 x 1 76.0 x 1 A 0.20 0.20 0.30 Model Name Power Supply Capacity Casing Color Dimensions Body Net Weight Body Heat Exchanger (Row x Column x Fins per inch) x No. Face Area 2 Type Indoor Units Fan Air Flow Rate Type Fan Motor Output Running Current 2 3 3 Sound Pressure Level H/M/L dB(A) 33 / 30 / 27 39 / 36 / 31 37 / 33 / 28 Sound Power Level Cooling dB(A) - - - Liquid mm(inch) 6.35 (1/4) 6.35 (1/4) 6.35 (1/4) Gas mm(inch) 9.52 (3/8) 9.52 (3/8) 12.7 (1/2) Drain (O.D. / I.D.) mm(inch) 21.5(27/32) / 16.0(5/8) 21.5(27/32) / 16.0(5/8) 21.5(27/32) / 16.0(5/8) Piping Connections Safety Devices Power and Communication Cable (included Earth) - Fuse Fuse Fuse - Thermal Protector for Fan Motor Thermal Protector for Fan Motor Thermal Protector for Fan Motor No. x AWG 4C x 18 4C x 18 4C x 18 Note : 1. Wiring cable size must comply with the applicable local and national code. 2. Due to our policy of innovation some specifications may be changed without notification. 3. Sound Level Values are measured at Anechoic chamber. Therefore, these values can be increased owing to ambient conditions during opration. 4. Acceptable operating voltage: 187V-253V 2 _ ART COOL Mirror ART COOL Mirror _ 3 264(10-13/32) 422(16-5/8) 327(12-7/8) 675(26-9/16) 895(35-1/4) 307(12-3/32) 70(2-3/4) 128(5-1/32) [Unit:mm(inch)] 46(1-13/16) 190(7-15/32) 205(8-1/16) 289(11-3/8) Display & signal receiver Air suction grille Knockout hole Installation plate 2 3 4 5 Remark 76, Seongsan-dong, Changwon City, Gyeongnam, 641-713, Korea CHASSIS CODE: SB 3. The Unit is powered from the outdoor unit. Therefore power cable should be connected with the outdoor unit. 2. Unit shall be grounded in accordance with the local regulations or applicable national codes. 1. Unit should be installed in compliance with the installation manual in the product box. Note Front panel Part Name AMNW09GDBR0[LMAN096HVT] AMNW12GDBR0[LMAN126HVT] 1 No. Indoor Units 307(12-3/32) 51(2) ART COOL Mirror Indoor unit 3. Dimensions 4 _ ART COOL Mirror Left rear piping Ø70(2-3/4) 105(4-1/8) 69(2-23/32) Unit Outline 1030(40-9/16) Measuring Tape Installation Plate Measuring Tape Hanger 460(18-1/8) 207(8-5/32) 56(2-7/32) Right rear piping Ø70(2-3/4) 190(7-15/32) 570(22-7/16) 362(14-1/4) Place a level on raised tab 362(14-1/4) 46(1-13/16) 52(2-1/16) [Unit:mm(inch)] 245(9-21/32) Display & signal receiver Air suction grille Knockout hole Installation plate 2 3 4 5 Part Name Front panel Remark 76, Seongsan-dong, Changwon City, Gyeongnam, 641-713, Korea CHASSIS CODE: SC 3. The Unit is powered from the outdoor unit. Therefore power cable should be connected with the outdoor unit. 2. Unit shall be grounded in accordance with the local regulations or applicable national codes. 1. Unit should be installed in compliance with the installation manual in the product box. Note ART COOL Mirror AMNW18GDCR0[LMAN186HVT] 1 No. Indoor Units Indoor unit 3. Dimensions 325(12-25/32) Indoor unit 4. Piping diagrams Gas pipe connection port (flare connection) Cooling Cross Flow Fan Thermistor for Evaporator Outlet Temperature Liquid pipe connection port (flare connection) Indoor Units Thermistor for Evaporator Inlet Temperature M Thermistor for Indoor Air Temperature Heating Heat Exchanger n Refrigerant pipe connection port diameters Unit : mm(inch) Model Gas Liquid AMNW09GDBR0 [LMAN096HVT] AMNW12GDBR0 [LMAN126HVT Ø9.52(3/8) Ø6.35(1/4) AMNW18GDCR0 [LMAN186HVT] Ø12.7(1/2) Ø6.35(1/4) Description Thermistor for Indoor Air Temperature Thermistor for Evaporator Inlet Temperature Thermistor for Evaporator Outlet Temperature PCB Connector CN_TH1 CN_TH2 Notes : Description is expressed based on Cooling mode. ART COOL Mirror _ 5 Indoor unit 5. Wiring diagrams Indoor Units Models : AMNW09GDBR0 [LMAN096HVT] / AMNW12GDBR0 [LMAN126HVT] Models : AMNW18GDCR0 [LMAN186HVT] 6 _ ART COOL Mirror Indoor unit 6. Capacity Tables n Cooling Capacity Outdoor Unit Size air temp. (kBtu/h(kW)) °F DB 9.0 (2.64) 12 (3.52) Indoor Air Temp. °F DB/ °F WB 68.0 / 57.2 71.6 / 60.8 77.0 / 64.4 TC SHC TC SHC TC 8.70 8.40 7.90 7.70 7.40 7.20 7.00 11.60 11.20 10.50 10.30 9.80 9.50 9.30 17.40 16.80 15.70 15.30 14.70 14.30 13.90 7.34 6.80 6.15 6.10 6.04 6.16 6.30 10.35 9.60 8.63 8.72 8.51 8.63 8.86 15.00 13.94 12.47 12.57 12.28 12.52 12.82 9.20 8.90 8.40 8.20 7.90 7.70 7.50 12.30 11.90 11.20 11.00 10.50 10.30 10.00 18.50 17.80 16.90 16.40 15.80 15.40 15.00 7.54 6.99 6.20 6.14 6.09 6.26 6.47 10.66 9.83 8.74 8.75 8.60 8.86 9.13 15.49 14.27 12.75 12.66 12.47 12.83 13.26 9.80 9.40 9.00 8.80 8.40 8.20 8.00 13.00 12.60 12.00 11.70 11.20 11.00 10.70 19.60 18.90 18.00 17.60 16.80 16.40 16.00 SHC 7.81 7.16 6.32 6.24 6.19 6.42 6.69 11.02 10.10 8.90 8.79 8.73 9.05 9.44 16.01 14.70 12.93 12.78 12.65 13.10 13.66 80.6 / 66.2 86.0 / 71.6 89.6 / 75.2 TC SHC TC SHC TC SHC 10.20 9.80 9.30 9.00 8.80 8.60 8.40 13.50 13.10 12.50 12.00 11.70 11.50 11.20 20.30 19.60 18.70 18.00 17.60 17.20 16.80 8.03 7.32 6.37 6.32 6.29 6.53 6.84 11.27 10.30 9.00 8.90 8.82 9.19 9.63 16.35 14.95 13.07 12.90 12.83 13.34 13.97 10.80 10.50 10.00 9.80 9.50 9.30 9.10 14.50 14.00 13.40 13.10 12.70 12.40 12.10 21.70 21.00 20.10 19.70 19.00 18.50 18.20 7.59 7.10 6.39 6.39 6.63 6.79 6.98 10.72 10.00 9.02 9.03 9.32 9.53 9.85 15.57 14.49 13.12 13.12 13.53 13.79 14.28 11.40 11.00 10.60 10.40 10.00 9.80 9.60 15.20 14.70 14.10 13.80 13.40 13.10 12.80 22.80 22.10 21.20 20.80 20.10 19.70 19.20 7.25 6.89 6.44 6.46 6.71 6.97 7.12 10.22 9.73 9.09 9.10 9.67 9.83 10.02 12.30 11.73 10.94 10.97 11.69 11.86 12.05 Notes: 1. Capacities are based on the following conditions. Corresponding refrigerant piping length : 25ft Level difference : 0ft 2. TC : Total Capacity(kBtu/h) SHC: Sensible Heat Capacity(kBtu/h) ART COOL Mirror _ 7 Indoor Units 18 (5.28) 68.0 77.0 89.6 95.0 104.0 109.4 114.8 68.0 77.0 89.6 95.0 104.0 109.4 114.8 68.0 77.0 89.6 95.0 104.0 109.4 114.8 Cooling Capacity Indoor unit 6. Capacity Tables n Heating Capacity Unit Size (kBtu/h(kW)) 9.0 (2.64) Indoor Units 12 (3.52) 18 (5.28) Indoor air temp. °F DB 60.8 64.4 68.0 70.0 71.6 75.2 60.8 64.4 68.0 70.0 71.6 75.2 60.8 64.4 68.0 70.0 71.6 75.2 Heating capacity Outdoor Air Temp. °F WB 5 14 23 32 TC TC TC 6.0 6.0 5.9 5.9 5.8 5.5 8.0 7.9 7.9 7.8 7.7 7.4 12.0 11.9 11.8 11.7 11.6 11.0 7.4 7.3 7.3 7.2 7.2 6.9 9.8 9.7 9.7 9.6 9.5 9.2 14.8 14.6 14.6 14.4 14.3 13.7 8.5 8.4 8.4 8.3 8.2 8.0 11.3 11.2 11.2 11.1 11.0 10.6 16.9 16.7 16.7 16.6 16.4 16.0 Notes: 1. Capacities are based on the following conditions. Corresponding refrigerant piping length : 25ft Level difference : 0ft 2. TC : Total Capacity(kBtu/h) 8 _ ART COOL Mirror 43 50 59 TC TC TC TC 9.5 9.4 9.4 9.3 9.2 9.0 12.6 12.5 12.5 12.4 12.3 12.0 18.9 18.8 18.7 18.5 18.4 17.9 10.5 10.4 10.4 10.4 10.3 10.0 14.0 13.9 13.9 13.8 13.7 13.4 20.9 20.8 20.7 20.8 20.5 20.0 10.9 10.9 10.9 10.8 10.7 10.5 14.6 14.5 14.5 14.4 14.3 13.9 21.9 21.8 21.7 21.6 21.4 20.9 11.0 10.9 10.9 10.8 10.8 10.5 14.6 14.5 14.5 14.4 14.3 14.0 22.0 21.8 21.8 21.6 21.5 20.9 Indoor unit 7. Air flow and temperature distributions (reference data) Model : AMNW09GDBR0 [LMAN096HVT] Cooling Heating Discharge angle : 40° Discharge angle : 50° Air velocity [ft/s] Air velocity [ft/s] 9ft 9ft 7ft 7ft 6.6 4.9 4.9 3ft 3ft 3.3 1.6 3.3 1.6 0ft 16ft 13ft 10ft 7ft 3ft 0ft 0ft 16ft Temperature [F] 13ft 10ft 7ft 3ft 0ft Temperature [F] 9ft 9ft 7ft 91 64 70 75 86 3ft 68 3ft 81 72 75 16ft 13ft 10ft 0ft 7ft 3ft 0ft 0ft 16ft 13ft 10ft 7ft 3ft 0ft Model : AMNW12GDBR0 [LMAN126HVT] Cooling Heating Discharge angle : 40° Discharge angle : 50° Air velocity [ft/s] Air velocity [ft/s] 9ft 9ft 7ft 7ft 6.6 6.6 3ft 3ft 4.9 1.6 3.3 3.3 1.6 4.9 0ft 16ft 13ft 10ft 7ft 3ft 0ft 16ft 0ft 13ft 10ft 7ft 3ft 0ft Temperature [F] Temperature [F] 9ft 9ft 7ft 7ft 91 64 70 86 3ft 68 3ft 81 75 16ft 13ft 10ft 75 72 7ft 0ft 3ft 0ft 0ft 16ft 13ft 10ft 7ft 3ft 0ft ART COOL Mirror _ 9 Indoor Units 7ft Indoor unit 7. Air flow and temperature distributions (reference data) Model : AMNW18GDCR0 [LMAN186HVT] Cooling Heating Discharge angle : 40° Discharge angle : 50° Air velocity [ft/s] Air velocity [ft/s] 8.2 1.6 26ft 23ft 20ft 16ft 13ft 10ft 9ft 9ft 7ft 7ft 3ft 4.9 3.3 7ft 1.6 3ft 0ft 0ft 3ft 6.6 3.3 26ft 23ft 20ft 16ft 13ft 10ft 7ft 4.9 3ft 0ft Temperature [F] Indoor Units Temperature [F] 9ft 9ft 7ft 7ft 91 64 68 23ft 20ft 16ft 10 _ ART COOL Mirror 13ft 3ft 10ft 7ft 81 75 3ft 0ft 0ft 26ft 23ft 20ft 16ft 3ft 86 70 72 75 26ft 0ft 13ft 10ft 7ft 3ft 0ft 0ft Indoor unit 8. Sound levels Overall Notes: - Sound measured at 3.3ft away from the center of the unit. - Data is valid at free field condition. - Data is valid at nominal operation condition. - Reference accoustic pressure 0dB=20Pa. - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed. - The operating conditions are assumed to be standard. 3.3ft 2.6ft Microphone Model AMNW09GDBR0 [LMAN096HVT] AMNW12GDBR0 [LMAN126HVT] AMNW18GDCR0 [LMAN186HVT] Sound Levels [dB(A)] H M L 33 30 27 39 36 31 37 33 28 Sound pressure level AMNW18GDCR0 [LMAN186HVT] 80 80 70 70 70 NC-65 60 NC-60 NC-55 50 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 Approximate Hearing Threshold NC-60 NC-55 50 NC-50 NC-15 125 250 500 1000 2000 4000 Octave Band Center Frequency (Hz) 8000 NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 Approximate Hearing Threshold NC-20 10 63 NC-65 60 NC-65 60 NC-60 NC-55 50 NC-50 NC-15 125 250 500 1000 2000 4000 Octave Band Center Frequency (Hz) 8000 NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 Approximate Hearing Threshold NC-20 10 63 Sound Pressure Level (dB re 20uPa) 80 Sound Pressure Level (dB re 20uPa) Sound Pressure Level (dB re 20uPa) AMNW12GDBR0 [LMAN126HVT] NC-20 NC-15 10 63 125 250 500 1000 2000 4000 8000 Octave Band Center Frequency (Hz) ART COOL Mirror _ 11 Indoor Units AMNW09GDBR0 [LMAN096HVT] Indoor unit 9. Controller Wireless remote control Control panel a Display screen Indoor Units Description F Plasma button*:Plasmaster filter purifies the air by removing mites, micro dust and pet fur. Plasmaster Ionizer sterilize the aerial bacteria and other harmful substances. l Sleep mode auto button*: Sets the sleep mode auto operation. e Temperature adjustment buttons: Adjusts the room temperature when cooling and heating. d Control panel Display screen - On/Off button: Turns the power on/off. fan speed button: Adjusts the fan g 7 v Indoor speed. f h Operation mode selection button*: A C Selects the operation mode. Cooling operation (A) / Auto operation or D B auto changeover (C) / Dehumidifying operE ation (D) / Heating operation (B) / Air circulation (E) N i j H I k S m nz c b u J G P Jet cooling/heating button*: Warms up or cools down the indoor temperature within a short period of time. Air flow direction button: Adjusts the air flow direction vertically or horizontally. Temperature display button: Displays the room temperature. Press key and hold it for longer than 5 second. Display change °C/°F Timer button: Sets the current time and the start / end time. Navigation and functions button*: Adjusts the time and sets the special functions. J: Auto clean / G: Operates energy saving cooling / P: Adjusts the brightness of the indoor unit display p - Set/clear button: Sets or cancels functions. r - Reset button: Resets the air conditioner settings. * Some functions may not be supported, depending on the model. 12 _ ART COOL Mirror Indoor unit 10. Installation • Please read the instruction sheets completely before installing the product. • When the power cord is damaged, replacement work shall be performed by authorized personnel only. • Installation work must be performed in accordance with the national wiring standards by authorized personal only. Installation plate Sleeve Bushing-Sleeve Putty(Gum Type Sealant) Bend the pipe as closely on the wall as possible, but be careful that it doesn't break. • Apply after carrying out a drainage test. • To carry out the drainage test, remove the air filters and pour water into the heat exchanger. Saddle 10.1 Accessories The following accessories are included with your unit. 1) Standard accessories 1. Type "A" screw 2. Installation plate Name Installation panel 3. Type "B" screw 4. Remote control holder Securing screws (Other) Type "A" screw Type "B" screw SB Chassis Diagram • Owner's manual • Installation manual M4 x 12L SC Chassis ART COOL Mirror _ 13 Indoor Units Vinyl tape (Wide) 14 _ ART COOL Mirror 133(5 1/4) Left rear piping Ø70(Ø2 3/4) Installation plate Indoor Units Unit : mm(inch) Right rear piping 95(3 3/4) Ø70(Ø2 3/4) Indoor unit 10. Installation 2) Installation plate dimensions Type 1: SB Chassis 69(2 23/32) Left rear piping Ø70(Ø2-3/4) 105(4 1/8) 460(18 1/8) Measuring Tape Hanger Measuring Tape Installation Plate Indoor Units Unit Outline Place a level on raised tab 570(22 7/16) Unit : mm(inch) 207(8 5/32) 56(2 7/32) Right rear piping Ø70(Ø2-3/4) Indoor unit 10. Installation Type 2: SC Chassis CAUTION • Use only those accessories (Standard or optional) which have designated specilications ART COOL Mirror _ 15 Indoor unit 10. Installation ① There should not be any heat or steam near the unit. ② Select a place where there are no obstacles around of the unit. ③ Make sure that condensation drainage can be conveniently routed away. ④ Do not install near a doorway. ⑤ Use a metal detector to locate studs to prevent unnecessary damage to the wall. Place a level on raised tab Unit Outline More than 200(7-7/8) More than 100(3-15/16) Recommended height 2000(78-3/4) Left rear piping Ø70 (Ø2 3/4) More than 100(3-15/16) Indoor Units ② Measure the wall and mark the centerline. It is also important to use caution concerning the location of the installation plate. Routing of the wiring to power outlets is through the walls typically. Drilling the hole through the wall for piping connections must be done safely. Ø70 (Ø2 3/4) Installation Plate 133(5 1/4) 175(6 7/8) 95(3 3/4) Right rear piping 10.2 Selection of the best location 217(8 17/32) Unit : mm(inch) 10.4 Before piping work Unit : mm(inch) CAUTION Note : Remove obstructions to prevent blockage of airflow path • Installation Information. For right piping. Follow the instruction given below. 10.3 Fixing installation plate Good case The wall you select should be strong and solid enough to prevent vibration ① Mount the installation plate on the wall with type "A" screws. If mounting the unit on a concrete wall, use anchor bolts. • Mount the installation plate horizontally by aligning the centerline using Horizontal meter . • Press on the upper side of clamp and unfold the tubing to downward slowly. Installation Plate Type "A" Screws Chassis Hook 16 _ ART COOL Mirror Indoor unit 10. Installation Wrong method 1) Installation of Indoor Unit • Following bending type from left to right may cause damage to the tubing. ① Hook the indoor unit onto the upper portion of the installation plate.( engage the three hooks at the top of the indoor unit with the upper edge of the installation plate) Ensure that the hooks are properly seated on the installation plate by moving it left and right Installation plate Tubing Holder Piping 10.5 Connecting the piping ① Pull the screw cap at the bottom of the indoor unit ② Remove the chassis cover from the unit by loosing 2 screws ① Insert the connecting cable through the bottom side of indoor unit and connect the cable (You can see detail contents in 'Connecting the cables' section) Chassis cover ③ Pull back the tubing holder. ④ Remove pipe port cover and positioning the tubing Indoor unit back side view View Tubing holder Terminal block Remote controller cable Connecting cable Cable retainer Right Downwards Left Backwards ART COOL Mirror _ 17 Indoor Units ② Unlock the tubing holder from the chassis and mount between the chassis and installation plate in order to separate the bottom side of the indoor unit from the wall Indoor unit 10. Installation Tape Connecting pipe View Drain hose Terminal block Remote controller cable Indoor Units Connecting cable Cable retainer ② Secure the cable onto the control board with the cable retainer. ③ Tape the tubing pipe, drain hose. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the upper side can cause overflow from the drain pan through the inside of the unit. 2) Connecting the installation pipe and drain hose to the indoor unit. ① Align the center of the pipes and sufficiently tighten the flare nut by hand ② Tighten the flare nut with a wrench Indoor unit tubing Flare nut Pipings Spanner (fixed) CAUTION If the drain hose is routed inside the room insulate the hose with an insulation material* so that dripping from sweating (condensation) will not damage furniture or floors. * Foamed polyethylene or equivalent is recommended. Flare nut Connection pipe Torque wrench ③ When needed to extend the drain hose of indoor unit, assembly the drain pipe as shown on the drawing Drain pipe Indoor unit drain hose Vinyl tape(narrow) Tape Connecting pipe Adhesive Drain hose 18 _ ART COOL Mirror Indoor unit 10. Installation 3) Wrap the insulation material around the connecting portion. ① Overlap the connection pipe heat insulation and the indoor unit pipe heat insulation material. Bind them together with vinyl tape so that there may be no gap. ② Wrap the area which accommodates the rear piping housing section with vinyl tape. Plastic bands Insulation material 4) Finishing the indoor unit installation ① Mount the tubing holder in the original positon. ② Ensure that the hooks are properly seated on the installation plate by moving it left and right. ③ Press the lower left and right sides of the unit against the installation plate until the hooks engage into their slots (clicking sound). ④ Finish the assembly by screwing the unit to the installation plate by using two pieces of type "C" screws. And assemble a chassis cover. Indoor unit pipe Connection pipe Type 'C' screw Pipe Vinyl tape(narrow) Before operating the units, detach two nitto tapes from the plasma filter. ③ Bundle the piping and drain hose together by wrapping them with cloth tape over the range within which they fit into the rear piping housing section. Wrap with vinyl tape Pipe Vinyl tape(wide) Drain hose Plasma Filter ART COOL Mirror _ 19 Indoor Units Wrap with vinyl tape Vinyl tape (wide) Indoor unit 10. Installation 10.6 Checking the Drainage 2) Drain piping 1) To check the drainage. ① The drain hose should point downward for easy drain flow. ① Pour a glass of water on the evaporator. ② Ensure the water flows through the drain hose of the indoor unit without any leakage and goes out the drain exit. Downward slope Connecting area drain hose ② Do not make drain piping like the following. Leakage checking Indoor Units Drain hose Leakage checking Water leakage Water leakage Tip of drain hose dipped in water Water leakage 20 _ ART COOL Mirror Accumulated drain water Air Do not raise Drain pan Ditch Waving Less than 50mm gap Indoor unit Ceiling cassette 4-way 1. List of functions 2. Specifications 3. Dimensions 4. Piping diagrams 5. Wiring Diagrams 6. Capacity Tables 7. Air flow and temperature distributions (reference data) 8. Sound levels 9. Controller 10. Installation Indoor unit 1. List of functions Category Air flow Air purifying Installation Convenience Individual control Network function Special function kit Others Air supply outlet Airflow direction control (left & right) Airflow direction control (up & down) Auto swing (left & right) Auto swing (up & down) Airflow steps (fan/cool/heat) Chaos wind(auto wind) Jet cool/heat Swirl wind Triple filter (Deodorizing) Plasma air purifier Allergy Safe filter Long-life prefilter (washable / anti-fungus) Drain pump E.S.P. control Electric heater High ceiling operation* Auto Elevation Grille Hot start Self diagnosis Soft dry operation Auto changeover Auto cleaning Auto operation(artificial intelligence) Auto Restart Child lock* Forced operation Group control* Sleep mode Timer(on/off) Timer(weekly)* Two thermistor control* Wired remote controller Deluxe wired remote controller Simple wired remote controller Simple Wired remote controller(for hotel use) Wireless remote controller General central controller (Non LGAP) Network Solution(LGAP) Dry contact PI 485(for Indoor Unit) Zone controller CTI(Communication transfer interface) Electronic thermostat Remote temperature sensor Telecom shelter controller AMNW12GTRA0 [LMCN125HV] AMNW18GTQA0 [LMCN185HV] 4 X Auto X O 4/5/4 O O/X O X PTPKQ0 X O O X X O X O O O X X O O O O O O O O O PQRCVSL0 / PQRCVSL0QW X PQRCVCL0Q / PQRCVCL0QW X O X O PQDSA(1)/PQDSB(1) / PQDSBC / PQDSBNGCM1 X X X X X X Note : 1. * : These functions need to connect the wired remote controller. O : Applied, X : Not applied Accessory model name : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package. Ceiling cassette 4-way _ 1 Indoor Units Reliability Function Indoor unit 2. Specifications AMNW12GTRA0 AMNW18GTQA0 [LMCN125HV] [LMCN185HV] V, Ø, Hz 208/230, 1, 60 208/230, 1, 60 Nominal kW Class 3.5 5.3 Nominal Btu/h Class 12,000 18,000 - - - WxHxD mm 570 × 214 × 570 570 × 256 × 570 WxHxD inch 22-7/16 x 8-7/16 x 22-7/16 22-7/16 x 10-3/32 x 22-7/16 kg (lbs) 14.0 (30.9) 15.0 (33.1) - (2 x 8 x 18) x 1 (2 x 10 x 18) x 1 m (ft ) 0.22 (2.40) 0.28 (3.00) - Turbo Fan Turbo Fan H/M/L m /min 9.5 / 8.0 / 7.0 13.0 / 12.0 / 11.0 H/M/L ft /min 335 / 283 / 247 459 / 424 / 388 - BLDC BLDC W x No. 43 x 1 43 x 1 Model Name Power Supply Capacity Casing Color Dimensions Body Net Weight Body Heat Exchanger (Row x Column x Fins per inch) x No. Face Area 2 Type Indoor Units Fan Air Flow Rate Type Fan Motor Output Running Current 2 3 3 A 0.25 0.25 Sound Pressure Level H/M/L dB(A) 38 / 35 / 32 38 / 37 / 34 Sound Power Level Cooling dB(A) - - Liquid mm(inch) 6.35 (1/4) 6.35 (1/4) Gas mm(inch) 9.52 (3/8) 12.7 (1/2) Drain (O.D. / I.D.) mm(inch) 32.0(1-1/4) / 25.0(31/32) 32.0(1-1/4) / 25.0(31/32) - Fuse Fuse - Thermal Protector for Fan Motor Thermal Protector for Fan Motor 4C x 18 4C x 18 - PT-UQC PT-UQC WxHxD mm 700 x 22 x 700 700 x 22 x 700 WxHxD inch 27-9/16 x 7/8 x 27-9/16 27-9/16 x 7/8 x 27-9/16 kg (lbs) 3.0 (6.6) 3.0 (6.6) Piping Connections Safety Devices Power and Communication Cable (included Earth) No. x AWG Model Name Decoration Panel Dimensions Net weight Note : 1. Wiring cable size must comply with the applicable local and national code. 2. Due to our policy of innovation some specifications may be changed without notification. 3. Sound Level Values are measured at Anechoic chamber. Therefore, these values can be increased owing to ambient conditions during opration. 4. Acceptable operating voltage: 187V-253V 2 _ Ceiling cassette 4-way Ceiling cassette 4-way _ 3 55(2 5/32) 2 1 380(14 31/32)(Air outlet hole) 473(18 5/8) 700 (27 9/16) R2 4- 2) 5/3 R2 0(4 - 378.6(14 29/32) 380(14 31/32)(Air outlet hole) 700 (27 9/16) 22(7/8) 3 523(20 19/32) 30(1 3/16) 84.5(3 5/16) 59.5(2 11/32) 19(3/4) 142.5(5 5/8) 4 5 6 7 570(22 7/16) 53(2 3/32) 461(18 5/32) 570(22 7/16) 517(20 11/32) Liquid pipe connection Drain pipe connection Power supply connection 6 7 Remark CHASSIS CODE: TR 3. The Unit is powered from the outdoor unit. Therefore power cable should be connected with the outdoor unit. 2. Unit shall be grounded in accordance with the local regulations or applicable national codes. Note 1. Unit should be installed in compliance with the installation manual in the product box. Gas pipe connection 5 Air discharge grille 3 4 Air suction grille 2 Part Name Decoration panel 1 No. AMNW12GTRA0[LMCN125HV]+PT-UQC 76, Seongsan-dong, Changwon City, Gyeongnam, 641-713, Korea Unit : mm(inch) 35(1 11/32) 570(22 7/16) Indoor Units 378.6(14 29/32) 172(6 25/32) 517(20 11/32) 214(8 7/16) Ceiling Cassette 4-way + Decoration Panel Indoor unit 3. Dimensions 2 1 55(2 5/32) 380(14 31/32)(Air outlet hole) 473(18 5/8) 700(27 9/16) 0( R2 4- 22(7/8) 2) /3 25 4R 378.6(14 29/32) 380(14 31/32)(Air outlet hole) 700(27 9/16) 4 _ Ceiling cassette 4-way 523(20 19/32) 95.5(3 3/4) 30(1 3/16) 125(4 29/32) 59.5(2 11/32) 19(3/4) 142.5(5 5/8) 4 5 6 7 570(22 7/16) 461(18 5/32) 570(22 7/16) 517(20 11/32) 517(20 11/32) Air suction grille Air discharge grille Gas pipe connection Liquid pipe connection Drain pipe connection Power supply connection 3 4 5 6 7 Remark CHASSIS CODE: TQ 3. The Unit is powered from the outdoor unit. Therefore power cable should be connected with the outdoor unit. 2. Unit shall be grounded in accordance with the local regulations or applicable national codes. Note 1. Unit should be installed in compliance with the installation manual in the product box. Decoration panel 2 Part Name 1 No. AMNW18GTQA0[LMCN185HV]+PT-UQC Ceiling Cassette 4-way + Decoration Panel 76, Seongsan-dong, Changwon City, Gyeongnam, 641-713, Korea Unit : mm(inch) 94(3 11/16) 76(3) 256(10 3/32) 3 378.6(14 29/32) 172(6 25/32) 570(22 7/16) Indoor Units Indoor unit 3. Dimensions Indoor unit 4. Piping diagrams Gas pipe connection port (flare connection) Cooling Turbo fan M Thermistor for Evaporator Outlet Temperature Thermistor for Evaporator Inlet Temperature Thermistor for Indoor Air Temperature Heating Heat exchanger Liquid pipe connection port (flare connection) Indoor Units n Refrigerant pipe connection port diameters Unit : mm(inch) Model Gas Liquid AMNW12GTRA0[LMCN125HV] Ø9.52(3/8) Ø6.35(1/4) AMNW18GTQA0[LMCN185HV] Ø12.7(1/2) Ø6.35(1/4) Description PCB Connector Thermistor for Indoor Air Temperature CN_ROOM Thermistor for Evaporator Inlet Temperature CN_PIPE/IN Thermistor for Evaporator Outlet Temperature CN_PIPE/OUT Notes : Description is expressed based on Cooling mode. Ceiling cassette 4-way _ 5 Indoor unit 5. Wiring diagrams Indoor Units Models: AMNW12GTRA0[LMCN125HV] / AMNW18GTQA0[LMCN185HV] 6 _ Ceiling cassette 4-way Indoor unit 6. Capacity Tables n Cooling Capacity Outdoor Unit Size air temp. (kBtu/h(kW)) °F DB 12 (3.52) 18 (5.28) 68.0 77.0 89.6 95.0 104.0 109.4 114.8 68.0 77.0 89.6 95.0 104.0 109.4 114.8 Cooling Capacity Indoor Air Temp. °F DB/ °F WB 68.0 / 57.2 71.6 / 60.8 77.0 / 64.4 TC SHC TC SHC TC 11.60 11.20 10.50 10.30 9.80 9.50 9.30 17.40 16.80 15.70 15.30 14.70 14.30 13.90 10.26 9.51 8.51 8.60 8.37 8.52 8.74 15.67 14.52 13.00 13.13 12.96 13.18 13.52 12.30 11.90 11.20 11.00 10.50 10.30 10.00 18.50 17.80 16.90 16.40 15.80 15.40 15.00 10.58 9.74 8.62 8.63 8.49 8.74 9.03 16.16 14.88 13.17 13.18 13.13 13.52 13.62 13.00 12.60 12.00 11.70 11.20 11.00 10.70 19.60 18.90 18.00 17.60 16.80 16.40 16.00 10.95 10.02 8.79 8.67 8.61 8.94 9.35 16.73 15.30 13.43 13.24 13.32 13.82 14.45 86.0 / 71.6 89.6 / 75.2 TC SHC TC SHC TC SHC 13.50 13.10 12.50 12.00 11.70 11.50 11.20 20.30 19.60 18.70 18.00 17.60 17.20 16.80 11.23 10.23 8.89 8.90 8.97 9.30 9.66 17.14 15.62 13.58 13.76 14.04 14.53 14.92 14.50 14.00 13.40 13.10 12.70 12.40 12.10 21.70 21.00 20.10 19.70 19.00 18.50 18.20 10.66 9.90 8.90 8.92 9.21 9.42 9.77 16.28 15.13 13.60 13.62 14.07 14.39 14.92 15.20 14.70 14.10 13.80 13.40 13.10 12.80 22.80 22.10 21.20 20.80 20.10 19.70 19.20 10.14 9.63 8.98 8.99 9.24 9.74 10.04 15.49 14.71 13.71 13.73 14.11 14.88 15.33 2. TC : Total Capacity(kBtu/h) SHC: Sensible Heat Capacity(kBtu/h) Ceiling cassette 4-way _ 7 Indoor Units Notes: 1. Capacities are based on the following conditions. Corresponding refrigerant piping length : 25ft Level difference : 0ft SHC 80.6 / 66.2 Indoor unit 6. Capacity Tables n Heating Capacity Unit Size (kBtu/h(kW)) 12 (3.52) Indoor Units 18 (5.28) Indoor air temp. °F DB 60.8 64.4 68.0 70.0 71.6 75.2 60.8 64.4 68.0 70.0 71.6 75.2 Heating capacity Outdoor Air Temp. °F WB 5 14 23 TC TC TC 8.0 7.9 7.9 7.8 7.7 7.4 12.0 11.9 11.8 11.7 11.6 11.0 9.8 9.7 9.7 9.6 9.5 9.2 14.8 14.6 14.6 14.4 14.3 13.7 11.3 11.2 11.2 11.1 11.0 10.6 16.9 16.7 16.7 16.6 16.4 16.0 Notes: 1. Capacities are based on the following conditions. Corresponding refrigerant piping length : 25ft Level difference : 0ft 8 _ Ceiling cassette 4-way 32 43 50 TC TC TC TC 12.6 12.5 12.5 12.4 12.3 12.0 18.9 18.8 18.7 18.5 18.4 17.9 14.0 13.9 13.9 13.8 13.7 13.4 20.9 20.8 20.7 20.8 20.5 20.0 14.6 14.5 14.5 14.4 14.3 13.9 21.9 21.8 21.7 21.6 21.4 20.9 14.6 14.5 14.5 14.4 14.3 14.0 22.0 21.8 21.8 21.6 21.5 20.9 2. TC : Total Capacity(kBtu/h) 59 Indoor unit 7. Air flow and temperature distributions (reference data) Model : AMNW12GTRA0[LMCN125HV] Cooling Heating Discharge angle: 40° Discharge angle: 50° Air velocity [ft/s] Air velocity [ft/s] 9ft 9ft 6.6 6.6 4.9 6.6 7ft 4.9 6.6 4.9 3.3 3.3 3.3 1.6 8ft 7ft 4.9 3.3 1.6 3ft 3ft 1.6 1.6 5ft 0ft 0ft 8ft 5ft 8ft 5ft 0ft 0m 8ft 5ft Temperature [°F] Temperature [°F] 9ft 9ft 91 64 68 7ft 68 72 91 86 75 72 2m 86 81 81 75 70 70 3ft 3ft 75 Indoor Units 64 75 8ft 5ft 0ft 5ft 0ft 8ft 8ft 5ft 0ft 0ft 8ft 5ft Model : AMNW18GTQA0[LMCN185HV] Cooling Heating Discharge angle : 40° Discharge angle : 50° Air velocity [ft/s] Air velocity [ft/s] 9ft 6.6 9ft 6.6 6.6 7ft 4.9 4.9 3.3 3.3 1.6 6.6 4.9 3.3 3ft 7ft 4.9 3.3 1.6 1.6 3ft 1.6 0ft 13ft 10ft 7ft 3ft 0ft 3ft 7ft 10ft 13ft 0ft 13ft Temperature [ßF] 10ft 7ft 3ft 0ft 3ft 7ft 10ft 13ft Temperature [ßF] 9ft 64 68 72 9ft 91 64 68 7ft 86 7ft 86 70 72 3ft 75 91 70 75 81 81 3ft 75 75 0ft 13ft 10ft 7ft 3ft 0ft 3ft 7ft 10ft 13ft 0ft 13ft 10ft 7ft 3ft 0ft 3ft 7ft 10ft 13ft Ceiling cassette 4-way _ 9 Indoor unit 8. Sound levels Overall Notes: - Sound measured at 4.9ft away from the center of the unit. - Data is valid at free field condition. - Data is valid at nominal operation condition. - Reference accoustic pressure 0dB=20Pa. - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed. - The operating conditions are assumed to be standard. Ceiling 4.9ft Sound Levels [dB(A)] H M L 38 35 32 38 37 34 Model AMNW12GTRA0[LMCN125HV] AMNW18GTQA0[LMCN185HV] AMNW12GTRA0 [LMCN125HV] AMNW18GTQA0 [LMCN185HV] 80 80 70 70 NC-65 60 NC-60 NC-55 50 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 Approximate Hearing Threshold NC-65 60 NC-60 NC-55 50 NC-50 NC-15 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) 10 _ Ceiling cassette 4-way NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 Approximate Hearing Threshold NC-20 10 63 Sound pressure level (dB re 20uPa) Sound pressure level (dB re 20uPa) Indoor Units Sound pressure level NC-20 NC-15 10 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) Indoor unit 9. Controller Wired remote controller(PQWRHDF0) PLASMA Button (Optional) Used to start or stop the plasma-purification function. JET COOL Button Speed cooling operates super high fan speed. OPERATION MODE SELECTION Button Used to select the operation mode. 8 FUNCTION SETTING Button Used to set or clear Auto Clean or Smart Clean. 1 9 LCD LUMINOSITY Button (Optional) Used to adjust LCD luminosity 2 10 SMART CLEAN Button (Optional) Used to start or stop Smart Clean. 3 12 CLEAR ALL Button Used to clear all timer. 4 13 14 ROOM TEMPERATURE SETTING Button Used to select the room temperature. 15 ON/OFF Button Used to turn on/off the unit. 16 INDOOR FAN SPEED SELECTION Button Used to select fan speed in four steps low, medium, high and chaos. 5 6 7 UP/DOWN AIRFLOW Button Used to stop or start louver movement and set the desired up/down airflow direction. LEFT/RIGHT AIRFLOW Button(Optional) Used to set the desired left/right(horizontal) airflow direction. Operation Mode Cooling Mode TIMER AND TIME SETTING Button Used to set the time of starting or stopping and sleeping operation. Auto Operation ROOM TEMPERATURE CHECKING Button Used to check the room temperature. Dehumidification mode C/ F SWITCH Button Used to switch temperature reading from Celsius to Fahrenheit. Heating Mode Fan Mode • Cooling Model( ), Heat Pump Model( ) RESET Button Used to reset the remote controller. NOTE h Some functions may not be operated and displayed depending on the product type. Ceiling cassette 4-way _ 11 Indoor Units 11 Indoor unit 10. Installation • Please read the instruction sheets completely before installing the product. • When the power cord is damaged, replacement work shall be performed by authorized personnel only. • Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Anti-fungus Indoor Units Air Outlet Air Inlet Wired Remote Controller (Accessory) 10.1 Accessories Check whether the following accessories are included with your unit. 1) Standard accessories Name Drain hose Quantity 1 EA Washer for Clamp metal hanging backet Shape 12 _ Ceiling cassette 4-way 1 EA 8 EA Clamp Conduit Bracket Insulation for fitting 8 EA 1 EA 1 SET Conduit Bracket for gas pipe Screw(M4) 2EA for liquid pipe (Other) • Paper pattern for installation • Owner's manual • Installation manual Indoor unit 10. Installation 10.2 Selection of the best location • There should not be any heat source or steam near the unit. • There should not be any obstacles to the air circulation. • There should be provision of easy condensate drain. • Taking into accounting the noise prevention criteria, spot the installation location. • Do not install the unit near the door way. • Keep proper distances, of the unit, from ceiling, fence, floor, walls and other obstacles as shown in figure. • The indoor unit must have the maintenance space. 10.3 Precautions regarding cassette indoor unit installation 1) Main points about the indoor installation - In case of high height ceiling In general commercial places and offices though the height of the ceiling is 2.3m(7.54ft)~2.7m(8.86ft), the ceiling height can be 3.1m(10.2ft)~3.6m(11.8ft). In such cases because of the temperature difference with the floor the heating effect can fall down. Discharge Suction H = At least 1800(70-7/8) 3600(141-23/32) or less 1000(39-3/8) or more Ceiling Board 500(19-11/16) or more Cold air Ceiling Board 300(11-13/16) or less Ceiling 500(19-11/16) or more Unit:mm(inch) Outdoor side (Entering of air by frequent opening and closing of door) - Countermeasure method ① Air conditioner must be able to operate in high ceiling conditioner. ② Plan to install the circulator. ③ The air discharge port is made to give more airflow to the down wood directions. Floor ④ The gate or exit of the building is protected by dual door system. NOTE Above figure means minimum value. Please keep these value at least. • High Ceiling mode selection No 1 2 3 4 Hot air Ceiling Height (H) H ≤ 2300(90-9/16) 2300(90-9/16) < H ≤ 2700(106-5/16) 2700(106-5/16) < H ≤ 3100(122-1/16) 3100(122-1/16) < H ≤ 3600(141-23/32) Unit : mm(inch) Mode Selection Low Ceiling Standard High Ceiling Super High Ceiling 2) In case the floor or surfaces of the place to be air conditioned is in direct contact with the outdoor air - The floor of the heating room indirect contact with the storeroom, garage or the outside air receives the cold air at the floor and the floor temperature decrease will feel cold at the feet. Indoor Low temperature of the floor Outdoor side Outdoor side Garage (50~100mm Insulation required) Outdoor side In such places where the feet comes in direct contact with floors will give a cold feeling to th floor. Ceiling cassette 4-way _ 13 Indoor Units 10(13/32) or more High elevation of the ceiling Indoor unit 10. Installation - Countermeasure: • Use the carpet on the floor (compared to the tiles the carpet over it will have a 3 degree rise in temperature) • Refrigerant piping: Increase the piping insulation thickness with thickness above 13/16 inch. Refrigerant piping • Insulating the floor. • Floor heating CAUTION Indoor Units • Case of cold air intake: The duct surface will have the dew drops so a insulation on the duct is a must.(Insulation material: a glass wool of thickness 1.0inch will be appropriate.) • Others: Inside the ceiling near th air tight seal places (To escape of the humidity inside false ceiling) 3) In case of high temperature or high humidity between the false ceiling and ceiling slab(near by the sea, river, lake, spa) - In case of temperature of 30 degree and humidity above 80%, the units body as well as the piping insulation should be strengthened. Refer to the picture given below. Psychrometric chart Enhance additional insulation required area Grill for ventilation 4) In case of multiple indoor cassette units (recommended) Indoor unit Indoor unit Ventilator Lighting Relative humidity 86F 59 1/16inch or more 78 25/32 inch or more - Places having the temperature and humidity of the surrounding water sources(sea, river etc.) In case the steam is generated between the false ceiling and the ceiling slab Due to some nearby by steam source. • Indoor unit: Insulate the unit body with some insulation like glass wool at least 13/32 inch in thickness. Additional insulation required 14 _ Ceiling cassette 4-way 118 5/32 inch or more Indoor unit 10. Installation 10.4 Ceiling opening dimensions and hanging bolt location ① The dimensions of the paper pattern for installation are the same as those of the ceiling opening dimensions. ② Select and mark the position for fixing bolts and piping hole. 1) Install the suspension bolts. (Use either a W3/8” or M10 size bolt) Use a hole-in anchor for existing ceilings, and a sunken insert, sunken anchor or other field supplied parts for new ceilings to reinforce the ceiling to bear the weight of the unit. Adjust clearance from the ceiling before proceeding further. ③ Decide the position for fixing bolts slightly tilted to the drain direction after considering the direction of drain hose. Ceiling Anchor Long nut or turn-buckle ④ Drill the hole for anchor bolt on the wall. Suspension bolt TQ/TR Chassis False ceiling 585~660(23-1/16~26) (Ceiling Opening) 585~660(23-1/16~26) (Ceiling Opening) Unit: mm(inch) All the above parts are field suppiled. 10.5 Indoor unit installation • Installing of the accessories (except for the decoration panel) before installing the indoor unit is easier. 1) Install the indoor unit. • Attach the hanger bracket to the suspension bolt. Be sure to fix it securely by using a nut and washer from the upper and lower sides of the hanger bracket. Hanging bolt (W3/8 or M10) Nut (W3/8 or M10) Flat washer for M10 (accessory) Spring washer (M10) Flat washer for M10 (accessory) Nut (W3/8 or M10) Ceiling Keep the length of the bolt from the bracket to 40(1-9/16) Air Conditioner body 180(7-3/32) 461(18-5/32) 517(20-3/8) Unit Size 319(12-9/16) 570(22-15/32) 570(22-15/32) Unit Size NOTE Ceiling board Ceiling board Keep the length of 30±3(1-3/16±1/8) between the air conditioner bottom surface and the ceiling surface Set screw of paper model (4 pieces) Paper model for installation Open the ceiling board along the outer edge of the paper model Unit : mm (inch) Ceiling cassette 4-way _ 15 Indoor Units 523(20-19/32) 517(20-3/8) Indoor unit 10. Installation • The following parts are local purchasing. 10.6 Connecting pipes to the indoor unit - Hanging Bolt - W 3/8 or M10 1) Refrigerant piping work - Nut - W 3/8 or M10 - Spring Washer - M10 - Plate Washer - M10 2) For new ceilings Indoor Units ① Refer to the paper pattern for ceiling opening dimension. • The center of the ceiling opening is indicated on the paper pattern for installation. The center of the unit is indicated on the label attached to the unit and on the paper pattern for installation. • First remove paper packaging material from the 4 corners of the paper pattern for installation , fix the paper pattern to the unit with screws. • Ceiling height is shown on the side of the paper pattern for installation. Adjust the height of the unit according to this indication. please refer “REFRIGERANT PIPING WORK”. 2) Piping insulation ① Perform heat insulation work completely on both gas and the liquid pipe. Because improper insulation will result condensate formation over pipe. ② Use the heat insulation material for the refrigerant piping which has an excellent heat resistance (over 248°F). ③ Precautions in high humidity circumstance: ④ Refer to insulation work CAUTION • Make sure to insulate any field piping all the way to the piping connection inside the unit. Any exposed piping may cause condensation or burns if touched. 3) Indoor unit drain piping ② Adjust the unit to the right position for installation. • Drain piping must have downward (1/50 to 1/100): be sure not to provide up-and-down slope to prevent reverse flow. ③ Assure that the unit is horizontal. • During drain piping connection, be careful not to exert extra force on the drain port on the indoor unit. • The indoor unit is equipped with a built-in drain pump and float switch. At each of the unit's 3 corners, verify that it is level by using awater-level or a water-filled vinyl tube. (Otherwise it will result in the malfunctioning of unit and cause water to drip.) ④ Remove the washer fixing plate used for preventing the washer from falling and tighten the upper nut. 5) Remove the paper pattern for installation • The outside diameter of the drain connection on the inddor unit is 1 1/4". Piping material: Polyvinyl chloride pipe 1" and pipe fittings p 3) For existing ceilings ① Adjust the height and position of the unit. ② Perform steps 3 and 4 in "5.1 For new ceilings". 16 _ Ceiling cassette 4-way 1/50~ 1/100 MAX 27 9/16" Upward routing not allowed Indoor unit 10. Installation • Be sure to install heat insulation on the drain piping. Heat insulation material: Polyethylene foam with thickness more than 13/32". 4) Drain test Feed water 10.7 Installation of decoration panel CAUTION • Properly install decoration panel because any slit or gab between unit and decoration panel will result cool air leakage which may responsible for water driblling. Air conditioner unit Flexible drain hose (Accessory) Main drain pipe Drain pump Drain port False ceiling Decoration panel Fit the insulation (this part) and be careful for cool air leakage Glue the joint Air conditioner unit Air Drain pan Cool air leakage(no good) False ceiling Decoration panel Flexible drain hose 1. Remove the packing and take out air inlet grille from front panel. Front grille 2. Remove the Corner covers of the panel. Coner cover Ceiling cassette 4-way _ 17 Indoor Units Drain hose connection use the clip (Accessory) Indoor unit 10. Installation 3. Fit the panel on the unit by inserting hooks as shown in picture. 6. Open two screws of control panel cover. Hook clip Screw Indoor Units Hook 4. Insert two screws on diagonal corners of panel. Do not tighten the bolts completely. (The fixing screws are included in the indoor unit box.) Check the alignment of panel with the ceiling. Height can be adjusted using hanging bolts as shown in picture. Insert the other two screws and tighten all screws completely. 7. Connect one display connector and two vane control connectors of front panel to indoor unit PCB. The position marking on PCB is as: Display connector : CN-DISP Vane control connector: CN-VANE 1,2 CN VANE 1,2 CN DISP 8. Close the cover for control box. 9. Fit the link on the panel as shown in picture. (The link is included in the front panel unit box.) Link 5. Fit the corner covers. 10. Attach the other side of link on the filter guide of inlet grille. Install the air inlet grille and filter on the panel. Link Filter guide 18 _ Ceiling cassette 4-way Indoor unit 10. Installation 12k/18kBtu/h Class (1Ø) 10.8 Electric wiring work Terminal block in indoor 1) General instructions ① All field supplied parts and materials, electric works must conform to local codes. Use copper wire only. ② Follow the "WIRING DIAGRAM” attached to the unit body to wire the outdoor unit, indoor units and the remote controller. ③ All wiring must be performed by an authorized electrician. ⑤ A circuit breaker capable of shutting down the power supply to the entire system must be installed. 2) Wiring Connection ① Open the control box cover and connect the Remote controller cord and Indoor power wires. 3 4 Connected to outdoor Unit 5 Air fresh kit (Option) ② Make sure to attach the sealing material (field supplied) to hole of wiring to prevent the infiltration of foreign particle from outside. Otherwise a short-circuit may occur inside the electric parts box ③ When clamping the wires, be sure no pressure is applied to the wire connections by using the included clamping material to make appropriate clamps. Also, when wiring, make sure the cover on the electric parts box fits snugly by arranging the wires neatly and attaching the electric parts box cover firmly. When attaching the electric parts box cover, make sure no wires get caught in the edges. Pass wiring through the holes to prevent damage to them. ④ Make sure the remote controller wiring, the wiring between the units, and other electrical wiring do not pass through the same locations outside of the unit, separating them properly, otherwise electrical noise (external static) could cause product malfunction. WARNING • Make sure that the screws of the terminal are not loose. 3) Conduit connection Indoor power cable ① Remove the bushing rubber product attached on the indoor unit. Bushing Remote controller cable Control Box Cover Control box cover screw ② Join the conduit and the conduit bracket together using nut. ③ Set the connecting cable into the terminal block of indoor unit, and tighten set screw to lock the conduit bracket to the indoor unit. Conduit bracket Screw Connecting Cable Conduit [The cable inlet view] Ceiling cassette 4-way _ 19 Indoor Units ④ This system consists of multiple indoor units. Mark each indoor unit as unit A, unit B..., and be sure the terminal board wiring to the outdoor unit and indoor units are properly matched. If wiring and piping between the outdoor unit and an indoor units are mismatched, the system may cause a malfunction. 1(L1) 2(L2) Indoor unit 10. Installation NOTE 1. Use round crimp-style terminals for connecting wires to the power supply terminal block. If unavailable, observe the following points when wiring. 3. Do not connect wires of different gauge to the same grounding terminal. Loose connection may deteriorate protection. • Do not connect wires of different gauge to the same power supply terminal. (Looseness connection may cause overheating.) 4. At the unit, keep proper separation between transmissio and power supply wiring. The equipment may malfunction if subjected to electrical (external) noise. • Use the specified electric wire. Connect the wire securely to the terminal. Lock the wire down without applying excessive force to the terminal. 5. Never connect power supply wiring to the terminal block for remote controller wiring. A mistake of the sort could damage the entire system. Attach insulation sleeve Indoor Units Round crimp-style terminal Electricwire Connect wires of the same gauge to both sides 2. Tightening torque for the terminal screws. • Use the correct screwdriver for tightening the terminal screws. If the blade of screwdriver is too small, the head of the screw might be damaged, and the screw will not be properly tightened. • If the terminal screws are tightened too hard, screws might be damaged. 20 _ Ceiling cassette 4-way 6. Use only specified wire and tightly connect wires to terminals. Be careful that wires should not place external stress on terminals. Keep wiring in neat order and so as not to obstruct other equipment such as popping open the electric parts box cover. Make sure the cover closes tight. Incomplete connections could result in overheating, and in worst case, electric shock or fire. Indoor unit Ceiling concealed duct - Low static pressure 1. List of functions 2. Specifications 3. Dimensions 4. Piping diagrams 5. Wiring Diagrams 6. Capacity Tables 7. External pressure setting 8. Sound levels 9. Controller 10. Installation Indoor unit 1. List of functions Category Air flow Air purifying Reliability Convenience Individual control Network function Special function kit Others Air supply outlet Airflow direction control (left & right) Airflow direction control (up & down) Auto swing (left & right) Auto swing (up & down) Airflow steps (fan/cool/heat) Chaos wind(auto wind) Jet cool/heat Swirl wind Triple filter (Deodorizing) Plasma air purifier Allergy Safe filter Long-life prefilter (washable / anti-fungus) Drain pump E.S.P. control* Electric heater High ceiling operation Auto Elevation Grille Hot start Self diagnosis Soft dry operation Auto changeover Auto cleaning Auto operation(artificial intelligence) Auto Restart Child lock* Forced operation Group control* Sleep mode Timer(on/off) Timer(weekly) Two thermistor control* Wired remote controller Deluxe wired remote controller Simple wired remote controller Simple Wired remote controller(for hotel use) Wireless remote controller* General central controller (Non LGAP) Network Solution(LGAP) Dry contact PI 485(for Indoor Unit) Zone controller CTI(Communication transfer interface) Electronic thermostat Remote temperature sensor Telecom shelter controller AMNW09GB1A0 [LMDN095HV] AMNW12GB1A0 [LMDN125HV] AMNW18GB2A0 [LMDN185HV] 1 X X X X 3/3/3 X X/X X X X X O O O X X X O O O X X O O O X O X X X O PQRCVSL0/PQRCVSL0QW X O X PQWRHDF0 X O PQDSA(1)/PQDSB(1) / PQDSBC / PQDSBNGCM1 X X X X X X Note : 1. * : These functions need to connect the wired remote controller. O : Applied, × : Not applied Accessory model name : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package. Ceiling concealed duct - low static pressure _ 1 Indoor Units Installation Function Indoor unit 2. Specifications AMNW09GB1A0 AMNW12GB1A0 AMNW18GB2A0 [LMDN095HV] [LMDN125HV] [LMDN185HV] V, Ø, Hz 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 Nominal kW Class 2.6 3.5 5.3 Nominal Btu/h Class 9,000 12,000 18,000 - - - - WxHxD mm 820 × 190 × 575 820 × 190 × 575 1,100 × 190 × 575 WxHxD inch Model Name Power Supply Capacity Casing Color Dimensions Body Net Weight Body Heat Exchanger kg (lbs) 20.5 (45.2) 20.5 (45.2) 26.5 (58.4) - (2 x 12 x 21) x 1 (2 x 12 x 21) x 1 (2 x 11 x 21) x 1 m (ft ) 0.16 (1.68) 0.16 (1.68) 0.21 (2.31) - Sirocco Fan Sirocco Fan Sirocco Fan H/M/L m /min 8.5 / 7.5 / 6.5 9.5 / 8.5 / 7.5 15.0 / 13.5 / 11.5 H/M/L ft /min 300 / 265 / 229 335 / 300 / 265 530 / 477 / 406 4(0.16) 4(0.16) 4(0.16) - BLDC BLDC BLDC W x No. (5 x 1) + (19 x 1) (5 x 1) + (19 x 1) 19 x 2 (Row x Column x Fins per inch) x No. Face Area 2 Type Indoor Units Fan Air Flow Rate 32-9/32 x 7-15/32 x 22-5/8 32-9/32 x 7-15/32 x 22-5/8 43-5/16 x 7-15/32 x 22-5/8 2 3 3 External Static Pressure mmAq(in.Aq) Type Fan Motor Output A 0.25 0.25 0.25 Sound Pressure Level Running Current H/M/L dB(A) 32 / 26 / 25 33 / 31 / 26 34 / 31 / 29 Sound Power Level Cooling dB(A) - - - Liquid mm(inch) 6.35 (1/4) 6.35 (1/4) 6.35 (1/4) Gas mm(inch) 9.52 (3/8) 9.52 (3/8) 12.7 (1/2) Drain (O.D. / I.D.) mm(inch) 32.0(1-1/4) / 25.0(31/32) 32.0(1-1/4) / 25.0(31/32) 32.0(1-1/4) / 25.0(31/32) - Fuse Fuse Fuse - Thermal Protector for Fan Motor Thermal Protector for Fan Motor Thermal Protector for Fan Motor 4C x 18 4C x 18 4C x 18 Piping Connections Safety Devices Power and Communication Cable (included Earth) No. x AWG Note : 1. Wiring cable size must comply with the applicable local and national code. 2. Due to our policy of innovation some specifications may be changed without notification. 3. Sound Level Values are measured at Anechoic chamber. Therefore, these values can be increased owing to ambient conditions during opration. 4. Acceptable operating voltage: 187V-253V 2 _ Ceiling concealed duct - low static pressure Ceiling concealed duct - low static pressure _ 3 64(2 17/32) 60(2 3/8) 165(6 1/2) 190(7 15/32) 21(13/16) 575(22 5/8) 36(1 13/32) 322(12 11/16) 289(11 3/8) 235(9 1/4) 154(6 1/16) 4 3 5 16(5/8) 6 820(32 9/32) 795(31 5/16) 903(35 9/16) 856(33 11/16) 728(28 21/32) 13(1/2) 2 1 Unit : mm(inch) Air discharge flange Gas pipe connection Liquid pipe connection Drain pipe connection Power supply connection 3 4 5 6 Remark 76, Seongsan-dong, Changwon City, Gyeongnam, 641-713, Korea CHASSIS CODE: B1 3. The Unit is powered from the outdoor unit. Therefore power cable should be connected with the outdoor unit. 2. Unit shall be grounded in accordance with the local regulations or applicable national codes. Note 1. Unit should be installed in compliance with the installation manual in the product box. Air suction flange 2 Part Name AMNW09GB1A0[LMDN095HV] AMNW12GB1A0[LMDN125HV] 1 No. Indoor Units 383(15 3/32) 14(9/16) 575(22 5/8) CEILING CONCEALED DUCT Indoor unit 3. Dimensions 190(7 15/32) 575(22 5/8) 96(3 25/32) 383(15 3/32) 18(23/32) 4 _ Ceiling concealed duct - low static pressure 18(23/32) 154(6 1/16) 18(23/32) 15(19/32) 1008(39 11/16) 1072(42 7/32) 1131(44 17/32) 1180(46 15/32) 1100(43 5/16) 40(1 9/16) 2 1 575(22 5/8) 6 170(6 11/16) 165(6 1/2) 3 5 4 Unit : mm(inch) Air discharge flange Gas pipe connection Liquied pipe connection Drain pipe connection Power supply connection 3 4 5 6 Remark 76, Seongsan-dong, Changwon City, Gyeongnam, 641-713, Korea CHASSIS CODE: B2 3. The Unit is powered from the outdoor unit. Therefore power cable should be connected with the outdoor unit. 2. Unit shall be grounded in accordance with the local regulations or applicable national codes. Note 1. Unit should be installed in compliance with the installation manual in the product box. Air suction flange 2 Part Name AMNW18GB2A0[LMDN185HV] CEILING CONCEALED DUCT 1 No. Indoor Units Indoor unit 3. Dimensions 10(13/32) 20(25/32) Indoor unit 4. Piping diagrams Models: AMNW09GB1A0[LMDN095HV] / AMNW12GB1A0[LMDN125HV] Gas pipe connection port (flare connection) Cooling Sirocco Fan M M Thermistor for Evaporator Outlet Temperature Liquid pipe connection port (flare connection) n Refrigerant pipe connection port diameters Model AMNW09GB1A0[LMDN095HV] AMNW12GB1A0[LMDN125HV] Unit : mm(inch) Gas Liquid ø9.52(3/8) ø6.35(1/4) Description PCB Connector Thermistor for Indoor Air Temperature CN_ROOM Thermistor for Evaporator Inlet Temperature CN_PIPE/IN Thermistor for Evaporator Outlet Temperature CN_PIPE/OUT Notes : Description is expressed based on Cooling mode. Ceiling concealed duct - low static pressure _ 5 Indoor Units Thermistor for Evaporator Inlet Temperature Thermistor for Indoor Air Temperature Heating Heat exchanger Indoor unit 4. Piping diagrams Models: AMNW18GB2A0[LMDN185HV] Gas pipe connection port (flare connection) Cooling M M Thermistor for Evaporator Outlet Temperature Thermistor for Evaporator Inlet Temperature Indoor Units Sirocco Fan Thermistor for Indoor Air Temperature Heating Heat exchanger Liquid pipe connection port (flare connection) n Refrigerant pipe connection port diameters Unit : mm(inch) Model Gas Liquid AMNW18GB2A0[LMDN185HV] ø12.7(1/2) ø6.35(1/4) Description PCB Connector Thermistor for Indoor Air Temperature CN_ROOM Thermistor for Evaporator Inlet Temperature CN_PIPE/IN Thermistor for Evaporator Outlet Temperature Notes : Description is expressed based on Cooling mode. 6 _ Ceiling concealed duct - low static pressure CN_PIPE/OUT Indoor unit 5. Wiring diagrams Models: AMNW09GB1A0[LMDN095HV] / AMNW12GB1A0[LMDN125HV] AMNW18GB2A0[LMDN185HV] Indoor Units Ceiling concealed duct - low static pressure _ 7 Indoor unit 6. Capacity Tables n Cooling Capacity Outdoor Unit Size air temp. (kBtu/h(kW)) °F DB 9.0 (2.64) Indoor Units 12 (3.52) 18 (5.28) 68.0 77.0 89.6 95.0 104.0 109.4 114.8 68.0 77.0 89.6 95.0 104.0 109.4 114.8 68.0 77.0 89.6 95.0 104.0 109.4 114.8 Cooling Capacity Indoor Air Temp. °F DB/ °F WB 68.0 / 57.2 71.6 / 60.8 77.0 / 64.4 TC SHC TC SHC TC 9.14 8.92 8.92 8.22 7.73 7.53 7.33 12.19 11.89 11.89 10.96 10.31 10.04 9.77 18.28 17.84 17.84 16.44 15.46 15.06 14.66 7.99 7.83 7.55 7.20 7.02 7.15 7.25 10.54 10.32 9.96 9.50 9.25 9.44 9.56 14.30 14.01 13.52 12.89 12.56 12.81 12.97 9.34 9.24 9.24 8.64 8.14 7.94 7.64 12.45 12.32 12.32 11.52 10.85 10.59 10.19 18.68 18.48 18.48 17.28 16.28 15.88 15.28 8.04 7.87 7.66 7.37 7.23 7.31 7.44 10.60 10.38 10.10 9.72 9.53 9.65 9.82 14.39 14.08 13.71 13.20 12.93 13.09 13.32 9.64 9.64 9.74 8.80 8.56 8.26 7.96 12.85 12.85 12.99 11.73 11.41 11.01 10.61 19.28 19.28 19.48 17.60 17.12 16.52 15.92 Notes: 1. Capacities are based on the following conditions. Corresponding refrigerant piping length : 25ft Level difference : 0ft 8 _ Ceiling concealed duct - low static pressure 80.6 / 66.2 86.0 / 71.6 89.6 / 75.2 SHC TC SHC TC SHC TC SHC 8.10 7.97 7.83 7.50 7.48 7.53 7.62 10.69 10.51 10.32 9.89 9.87 9.94 10.05 14.51 14.26 14.01 13.42 13.40 13.49 13.64 9.93 9.85 9.95 9.00 8.78 8.48 8.18 13.24 13.13 13.27 12.00 11.71 11.31 10.91 19.86 19.70 19.90 18.00 17.56 16.96 16.36 8.18 8.07 7.92 7.62 7.65 7.75 7.88 10.78 10.64 10.44 10.05 10.10 10.22 10.39 14.64 14.45 14.17 13.64 13.70 13.87 14.10 10.30 10.50 10.70 9.90 9.50 9.20 8.90 13.73 14.00 14.27 13.20 12.67 12.27 11.87 20.60 21.00 21.40 19.80 19.00 18.40 17.80 8.25 8.19 8.03 7.77 7.84 7.99 8.08 10.88 10.80 10.60 10.25 10.35 10.53 10.66 14.76 14.66 14.38 13.91 14.04 14.29 14.47 11.20 11.40 11.70 11.10 10.10 9.90 9.60 14.93 15.20 15.60 14.80 13.47 13.20 12.80 22.40 22.80 23.40 22.20 20.20 19.80 19.20 8.41 8.41 8.35 8.05 8.10 8.22 8.39 11.09 11.09 11.01 10.61 10.68 10.85 11.07 15.05 15.05 14.95 14.40 14.50 14.72 15.02 2. TC : Total Capacity(kBtu/h) SHC: Sensible Heat Capacity(kBtu/h) Indoor unit 6. Capacity Tables n Heating Capacity Unit Size (kBtu/h(kW)) 9.0 (2.64) 12 (3.52) 60.8 64.4 68.0 70.0 71.6 75.2 60.8 64.4 68.0 70.0 71.6 75.2 60.8 64.4 68.0 70.0 71.6 75.2 Outdoor Air Temp. °F WB 5 14 23 32 TC TC TC 6.0 6.0 5.9 5.9 5.8 5.5 8.0 7.9 7.9 7.8 7.7 7.4 12.0 11.9 11.8 11.7 11.6 11.0 7.4 7.3 7.3 7.2 7.2 6.9 9.8 9.7 9.7 9.6 9.5 9.2 14.8 14.6 14.6 14.4 14.3 13.7 8.5 8.4 8.4 8.3 8.2 8.0 11.3 11.2 11.2 11.1 11.0 10.6 16.9 16.7 16.7 16.6 16.4 16.0 Notes: 1. Capacities are based on the following conditions. Corresponding refrigerant piping length : 25ft Level difference : 0ft 43 50 59 TC TC TC TC 9.5 9.4 9.4 9.3 9.2 9.0 12.6 12.5 12.5 12.4 12.3 12.0 18.9 18.8 18.7 18.5 18.4 17.9 10.5 10.4 10.4 10.4 10.3 10.0 14.0 13.9 13.9 13.8 13.7 13.4 20.9 20.8 20.7 20.8 20.5 20.0 10.9 10.9 10.9 10.8 10.7 10.5 14.6 14.5 14.5 14.4 14.3 13.9 21.9 21.8 21.7 21.6 21.4 20.9 11.0 10.9 10.9 10.8 10.8 10.5 14.6 14.5 14.5 14.4 14.3 14.0 22.0 21.8 21.8 21.6 21.5 20.9 2. TC : Total Capacity(kBtu/h) Ceiling concealed duct - low static pressure _ 9 Indoor Units 18 (5.28) Indoor air temp. °F DB Heating capacity Indoor unit 7. External pressure setting E.S.P. Control provide required constant air flow rate irrespective of E.S.P. charge. CAUTION Installer setting mode is to set the detail function of the remote controller. If the installer setting mode is not set correctly, it can cause problems to the product, user injury or property damage. This must be set by an certificated installer, and any installation or change that is carried out by a non-certificated person should be responsible for the results. In this case, free service cannot be provided. want to set installer setting mode, Press 1 IftheyouTemperature up button and the oper mode button same time for five seconds. you enter the setting mode 2 When Initially. Function code is displayed on the LCD screen. Indoor Units FAN SPEED TEMP Function Code OPER MODE Value 1) General air-conditioner product No. 1 2 Function Test Run Address Setting Code 01 02 3 E.S.P. Value 03 4 Thermistor 04 5 Ceiling Height 05 6 Static Pressure 06 7 Master Setting 07 8 Celsius Fahrenheit Switching 12 Value 01:Set 00~FF : Address 01:VeryLow 0 ~ 255 02:Low 03:Med Function Code ESP step ESP value 04:High 05:Very High 01:Remo 02:Indoor 03:2TH 01:Med 02:Low 03:High 04:Very High 01:V-H 02:F-H 03:V-L 04:F-L 00:Slave 01:Master 00:Celsius (Optimized only for U.S.A) 01:Fahrenheit j Some contents may not be displayed depending on the product function 10 _ Ceiling concealed duct - low static pressure Indoor unit 7. External pressure setting How to Set E.S.P. on the remote controller? This is the function that decides the strength of the wind for each wind level and because this function is to make the installation easier. • If you set ESP incorrectly, the air conditioner may malfunction. • This setting must be carried out by a certificated-technician. 1 OPER MODE When pressing the button and button simultaneously for more than 3 seconds, the system will be entered into the installer setting mode. - After entering into the installer setting mode, select the E.S.P code value by pressing the button. * E.S.P code value : 03 OPER MODE FAN SPEED the button, [SLo→Lo→Med→Hi→Po] will be indicated. FAN SPEED FAN SPEED TEMP OPER MODE the desired air flow rate value 3 Select with the temperature up(▲), down(▼) button. * E.S.P value range : 0~255 - E.S.P value will be indicated at the upper right section of the display window. pressing the button, currently 4 When established E.S.P value will be set up. OPER MODE pressing the button and 5 When button simultaneously for more than 3 seconds after the setting has been completed, the setting mode will be released. - If there isn’t any button input for more than 25 seconds, the installer setting mode will also be released. • Precaution shall be taken not to alter the E.S.P value corresponded to each air flow section. • E.S.P value can be varied according to the products. • In the case of going to the next air flow rate stage by pressing the fan-speed button during the setup of the E.S.P value, the E.S.P value of previous air flow rate will be maintained by remembering the E.S.P value prior to the shift. Ceiling concealed duct - low static pressure _ 11 Indoor Units the desired air flow rate with 2 Select the button. Whenever pressing Indoor unit 7. External pressure setting E.S.P. setting value (reference) Static pressure(mmAq(in.Aq)) Model name 1(0.04) Step(Hi/Mid/Lo) 2(0.08) 3(0.12) 4(0.16) Setting value 8.5 CMM(300CFM) 75 84 94 104 114 7.5 CMM(265CFM) 69 77 88 99 110 6.5 CMM(230CFM) 62 71 83 95 106 9.5 CMM(336CFM) 82 90 99 109 118 8.5 CMM(300CFM) 75 84 94 104 114 7.5 CMM(265CFM) 69 77 88 99 110 15 CMM(530CFM) AMNW18GB2A0 13.5 CMM(477CFM) [LMDN185HV] 11.5 CMM(406CFM) 90 97 105 114 122 82 90 99 109 119 75 84 93 103 114 AMNW09GB1A0 [LMDN095HV] AMNW12GB1A0 [LMDN125HV] Indoor Units 0(0.0) [ Notes ] 1. To get the desired Airflow & E.S.P. combination from the table set the matching value from the table. Value other than that in table will not give the combinations of airflow & E.S.P. which are mentioned in the table. 2. Table data is based at 230V. According to the fluctuation of voltage, air flow rate varies. 12 _ Ceiling concealed duct - low static pressure Indoor unit 8. Sound levels Overall Notes: - Data is valid at nominal operation condition - Reference accoustic pressure OdB = 20Pa - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed. - The operating conditions are assumed to be standard. 4.9ft Ceiling 6.6ft Microphone Model AMNW09GB1A0[LMDN095HV] AMNW12GB1A0[LMDN125HV] AMNW18GB2A0[LMDN185HV] Sound Levels [dB(A)] H M L 32 26 25 33 31 26 34 31 29 Sound pressure level AMNW18GB2A0 [LMDN185HV] 80 80 70 70 70 NC-65 60 NC-60 NC-55 50 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 Approximate Hearing Threshold NC-60 NC-15 125 250 500 1000 2000 4000 Octave Band Center Frequency (Hz) 8000 NC-55 50 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 Approximate Hearing Threshold NC-20 10 63 NC-65 60 NC-65 60 NC-60 NC-15 125 250 500 1000 2000 4000 Octave Band Center Frequency (Hz) 8000 NC-55 50 NC-50 NC-45 40 NC-40 NC-35 30 NC-30 NC-25 20 Approximate Hearing Threshold NC-20 10 63 Octave Band Sound Pressure Level (dB re 20Pa ) 80 Octave Band Sound Pressure Level (dB re 20Pa ) Octave Band Sound Pressure Level (dB re 20Pa ) AMNW12GB1A0 [LMDN125HV] Indoor Units AMNW09GB1A0 [LMDN095HV] NC-20 NC-15 10 63 125 250 500 1000 2000 4000 8000 Octave Band Center Frequency (Hz) Ceiling concealed duct - low static pressure _ 13 Indoor unit 9. Controller 1) Wired remote controller Model name : PQRCVCL0QW (White Color_Supplied) / PQRCVCL0Q (Black Color_Accessory) 1. Operation Display Panel 2. Temperature Control Button 3. Fan Speed Button 1 4. On/Off Button Indoor Units 5. Operation Mode select Button 2 3 FAN SPEED 4 TEMP OPER MODE 5 14 _ Ceiling concealed duct - low static pressure Indoor unit 9. Controller 2) Wide wired remote controller(accessory) Model name : PQRCVSL0QW (White Color) / PQRCVSL0 (Black Color) 1 10 9 8 2 3 7 4 11 12 13 5 14 15 Please attach the inform label inside of the door. Please choose proper language depend on your country. 1 OPERATION INDICATION SCREEN 9 FUNCTION SETTING Button 2 SET TEMPERATURE Button 10 VENTILATION Button 3 FAN SPEED Button 11 RESERVATION 4 ON/OFF Button 5 OPRATION MODE SELECTION Button 12 UP,DOWN,LEFT,RIGHT Button • To check the indoor temperature, press button. 6 WIRELESS REMOTE CONTROLLER RECEIVER • Some products don't receive the wireless signals. 7 AIR FLOW Button 8 SUBFUNCTION Button 13 ROOM TEMPERATURE Button 14 SETTING/CANCEL Button 15 EXIT Button h Some functions may not be operated and displayed depending on the product type. Ceiling concealed duct - low static pressure _ 15 Indoor Units 6 Indoor unit 10. Installation • Please read the instruction sheets completely before installing the product. • When the power cord is damaged, replacement work shall be performed by authorized personnel only. • Installation work must be performed in accordance with the national wiring standards. Indoor Units Air outlet vents Air return Air filter 10.1 Accessories Check the following accessories are included with your unit. 1) Standard accessories Name Clamp metal Insulation for fitting Screws for duct flanges Clamp Conduit Bracket Quantity 1 EA 1 set 1 set 8 EA 1 EA (Other) • Owner's manual Shape for gas pipe Conduit Bracket for liquid pipe Screw(M4) 2EA 16 _ Ceiling concealed duct - low static pressure Indoor unit 10. Installation 10.2 Selection of the best location • B1/B2 Chassis B A Install the air conditioner in the location that satisfies the following conditions. C D • The place shall easily bear a load exceeding four times the indoor unitʼs weight. • The place shall be able to inspect the unit as the figure. • The place shall allow easy water drainage.(Suitable dimension “H” is necessary to get a slope to drain as figure.) • The place shall easily connect with the outdoor unit. • The place where the unit is not affected by an electrical noise. • The place where air circulation in the room will be good . Unit:mm(inch) Dimension A B C D E Capacity 9/12kBtu/h 856 903 383 575 96 Class (33-11/16) (35-9/16) (15-3/32) (22-5/8) (3-25/32) 18kBtu/h 1131 1180 383 575 96 Class (44-17/32) (46-15/32) (15-3/32) (22-5/8) (3-25/32) F 21 (13/16) 20 (25/32) 2) Relative positions of indoor unit, suspension bolt and inspection hatch size • B1/B2 Chassis Inspection Hole (600(23-5/8)X600(23-5/8)) 10.3 Ceiling dimension and hanging bolt location and service space Top view Control box 1) Select an installation site where the following conditions are fulfilled and that meets with your customer's approval. • If supporting structural members are not strong enough to take the units weight, the unit could fall out of place and cause serious injury. 600(23-5/8) 600(23-5/8) Unit:mm(inch) Front view • Where sufficient clearance of maintenance and service can be ensured. • Where optimum air distribution can be ensured. • Where nothing blocks the air passage. H=20(25/32) or more • Where condensate can be properly drained. • Where piping between indoor and outdoor units is possible within the allowable limit (Refer to the installation manual of the outdoor unit.) A • Keep the indoor and outdoor units, power cable and transmission wiring, at least 3.3ft from TVs and radios, to prevent distorted pictures and static.(Depending on the type and source of the electrical waves, static may be heard even when more than 3.3ft away.) B Unit:mm(inch) Capacity(Btu/h Class) A B 9/12k 600(23-5/8) 900(35-7/16) 18k 600(23-5/8) 1100(43-5/16) Ceiling concealed duct - low static pressure _ 17 Indoor Units • There should not be any heat source or steam near the unit. F E • The place where the unit shall be leveled. Indoor unit 10. Installation • Low static duct type in case of suction from back side. Air Filter 10.4 Position of suspension bolt ① A place where the unit will be leveled and that can support the weight of the unit. ② A place where the unit can withstand its vibration. ③ A place where service can be easily performed. Air outlet M10 Nut x4 (Local M10 SP. washer x 4 supply) M10 washer x4 Panel Rear • Low static duct type in case of suction from bottom side M10 washer x4 (Local M10 SP. washer x 4 supply) M10 Nut x4 Indoor Units Panel Rear Air outlet Air Filter 3) Install a canvass duct to the air discharge outlet and air inlet so that vibration from the machine body is not transmitted to the duct or ceiling. You should also apply acoustic (insulation material) to the inside of the duct, and vibration insulation rubber to the suspension bolts. ④ Select and mark the position for fixing bolts. ⑤ Drill the hole for set anchor on the face of ceiling. 4) Install suspension bolts. (Use bolts of 13/32 inch diameter.) • Install the equipment where supporting structures are strong enough to bear the equipment's weight. Use embedded inserts or anchor bolts with new buildings and hole-in-anchors with old buildings. CAUTION • Tighten the nut and bolt to prevent the unit falling. 18 _ Ceiling concealed duct - low static pressure Indoor unit 10. Installation ⑥ Insert the set anchor and washer onto the suspension bolts for locking the suspension bolts on the ceiling. ⑦ Mount the suspension bolts to the set anchor firmly. Liquid pipe ⑧ Secure the installation plates onto the suspension bolts (adjust level roughly) using nuts, washers and spring washers. Old building Refrigerant pipe and thermal insulation(Local supply) Clamp for insulation (Local supply) New building Insulation (Local supply) Union for gas pipe 1 Set anchor 2 Plate washer 3 Spring washer 5 Suspension bolts al Overlap with insulation 10.5 Connecting pipes to the indoor unit 1) Refrigerant piping work please refer “REFRIGERANT PIPING WORK”. Make sure that there is no clearance here. 2) Piping insulation ① Perform heat insulation work completely on both gas and the liquid pipe. Because improper insulation will result condensate formation over pipe. Use the heat insulation material for the refrigerant piping which has an excellent heat resistance (over 248°F). CAUTION • Make sure to insulate any field piping all the way to the piping connection inside the unit. Any exposed piping may cause condensation or burns if touched. ② Precautions in high humidity circumstance: This air conditioner has been tested according to the "KS Conditions" and confirmed that there is not any default. However, if it is operated for a long time in high humid atmosphere (dew point temperature: more than 73°F), water drops are liable to fall. In this case, add heat insulation material according to the following procedure: ③ Heat insulation material : Adiabatic glass wool with thickness 13/32 to 13/16 inch. ④ Stick glass wool on all air conditioners that are located in ceiling atmosphere. Ceiling concealed duct - low static pressure _ 19 Indoor Units Thermal insulation for refrigerant pipe (Local supply) Thermal insulation for piping(Local supply) 4 Nut Indoor unit 10. Installation 3) Indoor unit drain piping ① Drain piping must have down-slope (1/50 to 1/100): be sure not to provide up-and-down slope to prevent reversal flow. • Lay the drain hose with a downware inclination so water will drain out. Thermal insulator (Local supply) ② During drain piping connection, be careful not to exert extra force on the drain port on the indoor unit. Unit ③ The outside diameter of the drain connection on the indoor unit is 1 1/4 inch. Piping material: Polyvinyl chloride pipe inner diameter Ø1 inch and pipe fittings Make sure to be closed. Indoor Units CAUTION 1. Decline Installation of indoor unit is very important for the drain of the duct type air conditioner. 2. Minimum thickness of the insulation for the connecting pipe should be 7/32 inch. 4) Caution for gradient of unit and drain piping - Without drain pump: • Always lay the drain with downward inclination (1/50 to 1/100). Prevent any upward flow or reverse flow in any part. • 7/32 inch or thicker formed thermal insulation shall always be provided for the drain pipe. Correct method Attached drain hose Downward 1/50~1/100 or more Approx 3/32~5/32 inch ※ U-trap is not required for low static model in which the external static pressure is below 50 pa(5mm Aq) 20 _ Ceiling concealed duct - low static pressure Wrong method Drainage pipe (Local supply) Drainage hole Indoor unit 10. Installation - With drain pump ② Check the drainage ① Possible drain head height is upto 27 6/19 inch. So the drain head should be below 27 6/19 inch. • Spray one or two glasses of water on the evaporator. ② Keep the drain hose downward upto 1/50~1/100 inclination. Prevent any upward flow or reverse flow in any part. • Ensure that water flows through the drain hose from indoor unit without any leakage. ③ 7/32 inch or thicker insulation should be provided for the drain pipe. 1/50~1/100 Drain Pipe MAX 27 9/16 inch 10.6 Electric wiring work 1) General instructions Thermal insulation (Local supply) Drain pipe (Local supply) Unit Elbow Drain pump 5) Checking the drainage ① Remove the air filter. ① All field supplied parts and materials, electric works must conform to local codes. Use copper wire only. ② Follow the "WIRING DIAGRAM” attached to the unit body to wire the outdoor unit, indoor units and the remote controller. ③ All wiring must be performed by an authorized electrician. ④ This system consists of multiple indoor units. Mark each indoor unit as unit A, unit B..., and be sure the terminal board wiring to the outdoor unit and ID unit are properly matched. If wiring and piping between the outdoor unit and an indoor unit are mismatched, the system may cause a malfunction. ⑤ A circuit breaker capable of shutting down the power supply to the entire system must be installed. 2) Wiring connection Connect the wires to the terminals on the control board ind vidually according to the outdoor unit connection. • Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit respectively Terminal block in indoor 1(L1) 2(L2) 3 Connected to outdoor unit Ceiling concealed duct - low static pressure _ 21 Indoor Units Drain Pump Indoor unit 10. Installation Clamping of cables ① Arrange 2 power cables on the control panel. ② First, fasten the steel clamp with a screw to the inner boss of control panel. ③ For the cooling model, fix the other side of the clamp with a screw strongly. For the heat pump model, put the 0.75mm2 cable (thinner cable) on the clamp and tighten it with a plastic clamp to the other boss of the control panel. ④ In Australia, the length of power supply cord measured from the entry of the power supply cord to the middle of live pin on the power plug should be over 5.9ft. CAUTION 1. Use round crimp-style terminals for connecting wires to the power supply terminal block. If unavailable, observe the following points when wiring. • Do not connect wires of different gauge to the same power supply terminal. • Use the specified electric wire. Connect the wire securely to the terminal. Lock the wire down without applying excessive force to the terminal. Attach insulation sleeve • Make sure that the screws of the terminal are fixed tightly. Indoor Units NOTE 3) Conduit connection ① Remove the busing rubber product attached on the indoor unit. ② Set the connecting cable into the terminal block of indoor unit, and tighten set screw to lock the conduit bracket to the indoor unit. ③ Join the conduit and the conduit bracket together. Round crimp-style terminal Electric wire Connect wires of the same gauge to both sides Lock nut Conduit Conduit mounting plate CAUTION • Make sure to attach the sealing material or (field supplied) to hole of wiring to prevent the infiltration of foreign particle from outside. Otherwise a short-circuit may occur inside the electric parts box • When clamping the wires, be sure no pressure is applied to the wire connections by using the included clamping material to make appropriate clamps. Also, when wiring, make sure the cover on the electric parts box fits snugly by arranging the wires neatly and attaching the electric parts box cover firmly. When attaching the electric parts box cover, make sure no wires get caught in the edges. Pass wiring through the wiring through holes to prevent damage to them. • Make sure the remote controller wiring, the wiring between the units, and other electrical wiring do not pass through the same locations outside of the unit, separating them properly, otherwise electrical noise (external static) could cause product malfunction. 22 _ Ceiling concealed duct - low static pressure 2. Tightening torque for the terminal screws. • Use the correct screwdriver for tightening the terminal screws. If the blade of screwdriver is too small, the head of the screw might be damaged, and the screw will not be properly tightened. • If the terminal screws are tightened too hard, screws might be damaged. 3. Do not connect wires of different gauge to the same grounding terminal. Loose connection may deteriorate protection. 4. Outside of the unit, keep proper separation between transmission and power supply wiring. The equipment may malfunction if subjected to electrical (external) noise. 5. Never connect power supply wiring to the terminal block for remote controller wiring. A mistake of the sort could damage the entire system. 6. Use only specified wire and tightly connect wires to terminals. Be careful wires do not place external stress on terminals. Keep wiring in neat order and so as not to obstruct other equipment such as popping open the electric parts box cover. Make sure the cover closes tight. Incomplete connections could result in overheating, and in worse case, electric shock or fire. P/No.: MFL67502502 Air Conditioner 20 Yeouido-dong, Yeongdeungpo-gu, Yeouido P.O.Box 335 Seoul, 150-721, Korea. http://www.lgeaircon.com All rights reserved Printed in Korea December / 2012 The specifications, designs, and information in this brochure are subject to change without notice. The air conditioners manufactured by LG have received ISO9001 certificate for quality assurance and ISO14001 certificate for environmental management system.