Preview only show first 10 pages with watermark. For full document please download

Indoor Unit Outdoor Unit Asyg07ljca Aoyg45lat8

   EMBED


Share

Transcript

HYBRID FLEX INVERTER SYSTEM Outdoor unit AOYG45LAT8 Branch box UTP-PY02A UTP-PY03A Separation tube UTP-SX248A CONTENTS SPECIFICATIONS . . . . . . . . . . . . . . . . . . . 1 DIMENSIONS. . . . . . . . . . . . . . . . . . . . . . . 8 REFRIGERANT SYSTEM DIAGRAM . . . 18 CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . .20 OUTDOOR PCB CIRCUIT DIAGRAM . . . 30 BRANCH BOX PCB CIRCUIT DIAGRAM. . . 36 INDOOR PCB CIRCUIT DIAGRAM . . . . . 40 ERROR DETECTION. . . . . . . . . . . . . . . .60 PARTS (OUTDOOR UNIT) . . . . . . . . . . . 65 PARTS (BRANCH BOX) . . . . . . . . . . . . . 69 PARTS (INDOOR UNIT) . . . . . . . . . . . . . 72 ACCESSORIES . . . . . . . . . . . . . . . . . . . 105 Indoor unit ASYG07LJCA ASYG09LJCA ASYG12LJCA ASYG18LFCA ASYG24LFCA AUYG07LVLA AUYG09LVLA AUYG12LVLA AUYG14LVLA AUYG18LVLA UTG-UFYD-W AGYG09LVCA AGYG12LVCA AGYG14LVCA ARYG07LLTA ARYG09LLTA ARYG12LLTA ARYG14LLTA ARYG18LLTA ABYG14LVTA ABYG18LVTA SPECIFICATIONS OUTDOOR UNIT ELECTRICAL DATA Hybrid flex inverter system TYPE MODEL NAME AOYG45LAT8 POWER SUPPLY FREQUENCY Cooling CAPACITY Heating INPUT POWER Cooling Heating Cooling CURRENT Heating 230 V 50 Hz 48,000 Btu/h (14.0 kW) 51,100 Btu/h Rated Max Rated 54,000 Btu/h (16.0 kW) 57,000 Btu/h Max 5.20 kW Rated Max. Rated Max. 5.98 kW 5.07 kW 5.98 kW 23.1 A 26.5 A Rated Max. Rated Max. 22.5 A 26.5 A FAN MOTOR DISCRIMINATION Cooling SPEED Heating MFE-45WVN 890 r.p.m. 910 r.p.m. AIR FLOW Cooling (Rated) Heating (Rated) 4,650 m3/h NOISE LEVEL Cooling (Rated) Heating (Rated) 56 dB(A) 58 dB(A) 4,800 m3/h COMPRESSOR AND REFRIGERANT Hermetic type, Inverter, 4 poles, 3-phase, DC motor, Twin Rotary 808 688 80(B) 26.0 kg TYPE DISCRIMINATION WEIGHT 3,450 g R410A PRECHARGED REFRIGERANT REFRIGERANT TYPE MEASUREMENT DIMENSIONS WEIGHT HxWxD 914 x 970 x 370 mm Net / Shipping 98 kg / 106 kg BRANCH BOX ELECTRICAL DATA UTP-PY03A (3 branch) UTP-PY02A (2 branch) 62,000 Btu/h MODEL NAME MAX. COMBINATION MIN. COMBINATION 7,000 Btu/h 10 W POWER CONSUMPTION RUNNING CURRENT 0.05 A MEASUREMENT DIMENSIONS WEIGHT 2010.10.28 HxWxD 195 x 433 x 370 mm Net / Shipping 9 kg / 13 kg 1 INDOOR UNIT COMPACT WALL MOUNTED ELECTRICAL DATA MODEL NAME CAPACITY ASYG07LJCA 2.0 kW class FAN MOTOR High Cooling FAN SPEED Heating Cooling Heating Cooling NOISE LEVEL Heating 2011.01.25 Medium Low Quiet High Medium Low 1,050 r.p.m. 950 r.p.m. 1,100 r.p.m. 1,200 r.p.m. 980 r.p.m. 1,050 r.p.m. 850 r.p.m. 710 r.p.m. 850 r.p.m. 710 r.p.m. 1,100 r.p.m. 880 r.p.m. 710 r.p.m. 1,200 r.p.m. 980 r.p.m. 850 r.p.m. 1,050 r.p.m. 1,050 r.p.m. 950 r.p.m. 720 r.p.m. 910 r.p.m. 720 r.p.m. 560 m /h 600 m3/h 660 m3/h 500 m3/h 520 m3/h 560 m3/h 430 m3/h 340 m3/h 430 m3/h 340 m3/h 450 m3/h 340 m3/h 560 m3/h 600 m3/h 660 m3/h Medium 500 m3/h 520 m3/h 560 m3/h Low Quiet 430 m3/h 350 m3/h 430 m3/h 350 m3/h 470 m3/h 350 m3/h High 36 dB(A) 37 dB(A) 40 dB(A) Medium 32 dB(A) 33 dB(A) 36 dB(A) Low Quiet High 29 dB(A) 25 dB(A) 29 dB(A) 25 dB(A) 30 dB(A) 25 dB(A) 36 dB(A) 32 dB(A) 37 dB(A) 33 dB(A) 40 dB(A) 36 dB(A) 29 dB(A) 29 dB(A) 31 dB(A) 25 dB(A) 25 dB(A) 25 dB(A) Quiet High Medium Low Quiet High AIR FLOW DIMENSIONS WEIGHT ASYG12LJCA 3.5 kW class MFD-12TYAN DISCRIMINATION MEASUREMENTS ASYG09LJCA 2.5 kW class Medium Low Quiet 850 r.p.m. 720 r.p.m. 3 HxWxD Net / Shipping 280 x 790 x 203 mm 8.0 kg / 10.5 kg 2 INDOOR UNIT WALL MOUNTED ELECTRICAL DATA MODEL NAME CAPACITY ASYG18LFCA 5.0 kW class FAN MOTOR MFD-50RON DISCRIMINATION Cooling FAN SPEED Heating Cooling Heating Cooling NOISE LEVEL Heating DIMENSIONS WEIGHT 2011.01.25 High 1,250 r.p.m. 1,480 r.p.m. Medium 1,020 r.p.m. 1,220 r.p.m. 900 r.p.m. 1,020 r.p.m. 770 r.p.m. 1,250 r.p.m. 1,020 r.p.m. 900 r.p.m. 1,430 r.p.m. 1,220 r.p.m. 900 r.p.m. 1,020 r.p.m. 790 r.p.m. 900 r.p.m. High 920 m /h 1,120 m3/h Medium Low 740 m3/h 900 m3/h 620 m /h 550 m3/h 740 m3/h 620 m3/h 920 m3/h 1100 m3/h Medium 740 m3/h 900 m3/h Low Quiet 620 m3/h 550 m3/h 740 m3/h 620 m3/h High 43 dB(A) 49 dB(A) Medium Low Quiet 37 dB(A) 33 dB(A) 31 dB(A) 42 dB(A) 37 dB(A) 33 dB(A) High Medium 44 dB(A) 37 dB(A) 48 dB(A) 42 dB(A) Low 33 dB(A) 37 dB(A) Quiet 31 dB(A) 33 dB(A) Low Quiet High Medium Low Quiet 3 3 Quiet High AIR FLOW MEASUREMENTS ASYG24LFCA 7.0 kW class HxWxD Net / Shipping 320 x 998 x 228 mm 14 kg / 18 kg 3 INDOOR UNIT COMPACT CASSETTE ELECTRICAL DATA MODEL NAME CAPACITY AUYG07LVLA 2.0 kW class AUYG09LVLA AUYG12LVLA AUYG14LVLA 2.5 kW class 3.5 kW class 4.0 kW class FAN MOTOR DISCRIMINATION MFF-24RVL Cooling FAN SPEED Heating Cooling High Medium 590 r.p.m. 540 r.p.m. 590 r.p.m. 540 r.p.m. 660 r.p.m. 580 r.p.m. 730 r.p.m. Low Quiet High Medium 490 r.p.m. 440 r.p.m. 490 r.p.m. 440 r.p.m. 520 r.p.m. 460 r.p.m. 540 r.p.m. 590 r.p.m. 540 r.p.m. 590 r.p.m. 540 r.p.m. 650 r.p.m. 580 r.p.m. 740 r.p.m. 670 r.p.m. 840 r.p.m. 750 r.p.m. Low 490 r.p.m. 490 r.p.m. 520 r.p.m. 600 r.p.m. 650 r.p.m. Quiet 440 r.p.m. 440 r.p.m. 460 r.p.m. 480 r.p.m. 500 r.p.m. High Medium Low 540 m3/h 540 m3/h 610 m3/h 680 m3/h 750 m3/h 490 m3/h 490 m3/h 530 m3/h 580 m3/h 610 m3/h 440 m3/h 390 m3/h 440 m3/h 390 m3/h 470 m3/h 410 m3/h 490 m3/h 410 m3/h 520 m3/h 410 m3/h 540 m3/h 540 m3/h 610 m3/h 700 m3/h 800 m3/h Medium 490 m /h 490 m /h 530 m /h 620 m /h 710 m3/h Low Quiet 440 m3/h 390 m3/h 440 m3/h 390 m3/h 470 m3/h 410 m3/h 550 m3/h 430 m3/h 600 m3/h 450 m3/h High Medium 33 dB(A) 31 dB(A) 33 dB(A) 31 dB(A) 37 dB(A) 33 dB(A) 40 dB(A) 35 dB(A) 42 dB(A) 37 dB(A) Low Quiet 29 dB(A) 27 dB(A) 29 dB(A) 27 dB(A) 31 dB(A) 28 dB(A) 32 dB(A) 29 dB(A) 33 dB(A) 29 dB(A) High Medium Low 34 dB(A) 32 dB(A) 34 dB(A) 32 dB(A) 37 dB(A) 33 dB(A) 40 dB(A) 37 dB(A) 44 dB(A) 40 dB(A) 29 dB(A) 29 dB(A) 31 dB(A) 34 dB(A) 37 dB(A) Quiet 27 dB(A) 27 dB(A) 28 dB(A) 29 dB(A) 30 dB(A) Quiet High AIR FLOW Heating Cooling NOISE LEVEL Heating MEASUREMENTS DIMENSIONS WEIGHT 3 3 3 HxWxD Net / Shipping 245 x 570 x 570 mm 15 kg / 18 kg HxWxD Net / Shipping 49 x 700 x 700 mm 2.6 kg / 4.5 kg PANEL MEASUREMENTS UTG-UFYD-W MODEL NAME DIMENSIONS WEIGHT 2011.01.25 AUYG18LVLA 5.0 kW class 4 630 r.p.m. 460 r.p.m. 3 790 r.p.m. 660 r.p.m. 570 r.p.m. 460 r.p.m. INDOOR UNIT FLOOR ELECTRICAL DATA MODEL NAME CAPACITY AGYG09LVCA AGYG12LVCA AGYG14LVCA 2.5 kW class 3.5 kW class 4.0 kW class FAN MOTOR DISCRIMINATION MFD-14TXN (upper) / MFD-14SXN (lower) Cooling FAN SPEED (upper fan / lower fan) Heating Cooling AIR CIRCULATION HIGH (2 fan running) Heating Cooling NOISE LEVEL Heating High 1,120 / 950 r.p.m. 1,240 / 1,050 r.p.m. 1,330 / 1,120 r.p.m. Medium 960 / 820 r.p.m. 1,050 / 890 r.p.m. 1,100 / 930 r.p.m. Low 820 / 700 r.p.m. 860 / 730 r.p.m. 890 / 750 r.p.m. Quiet 660 / 560 r.p.m. 660 / 560 r.p.m. 660 / 560 r.p.m. High 1,120 / 950 r.p.m. 1,240 / 1,050 r.p.m. 1,330 / 1,120 r.p.m. Medium 1,000 / 850 r.p.m. 1,080 / 920 r.p.m. 1,140 / 970 r.p.m. Low 860 / 730 r.p.m. 910 / 770 r.p.m. 940 / 800 r.p.m. Quiet 660 / 560 r.p.m. 660 / 560 r.p.m. 660 / 560 r.p.m. High 570 m3/hr 570 m3/hr 650 m3/hr Medium 460 m3/hr 460 m3/hr 520 m3/hr Low 390 m3/hr 360 m3/hr 400 m3/hr Quiet 270 m3/hr 270 m3/hr 270 m3/hr High 600 m3/hr 600 m3/hr 650 m3/hr Medium 480 m3/hr 480 m3/hr 520 m3/hr Low 370 m3/hr 370 m3/hr 390 m3/hr Quiet 270 m3/hr 270 m3/hr 270 m3/hr High 39 dB(A) 42 dB(A) 44 dB(A) Medium 34 dB(A) 36 dB(A) 38 dB(A) Low 28 dB(A) 30 dB(A) 31 dB(A) Quiet 22 dB(A) 22 dB(A) 22 dB(A) High 39 dB(A) 42 dB(A) 44 dB(A) Medium 35 dB(A) 38 dB(A) 39 dB(A) Low 30 dB(A) 32 dB(A) 33 dB(A) Quiet 22 dB(A) 22 dB(A) 22 dB(A) MEASUREMENT DIMENSIONS WEIGHT 2011.01.25 600 x 740 x 200 mm HxWxD 14 kg / 17 kg Net / Shipping 5 INDOOR UNIT SLIM DUCT ELECTRICAL DATA ARYG07LLTA 2.0 kW class MODEL NAME CAPACITY ARYG09LLTA 2.5 kW class FAN MOTOR Cooling FAN SPEED Heating Cooling AIR FLOW Heating Cooling NOISE LEVEL Heating 2011.01.25 ARYG18LLTA 5.0 kW class MFG-24WV High 1,160 r.p.m. 1,260 r.p.m. 1,340 r.p.m. 1,560 r.p.m. 1,380 r.p.m. Medium 1,000 r.p.m. 1,160 r.p.m. 1,240 r.p.m. 1,400 r.p.m. 1,300 r.p.m. 940 r.p.m. 880 r.p.m. 1,060 r.p.m. 960 r.p.m. 1,260 r.p.m. 1,140 r.p.m. 1,030 r.p.m. 1,340 r.p.m. 1,240 r.p.m. 1,030 r.p.m. 1,560 r.p.m. 1,220 r.p.m. 1,140 r.p.m. 1,380 r.p.m. 1,160 r.p.m. 1,240 r.p.m. 1,400 r.p.m. 1,300 r.p.m. 1,060 r.p.m. 1,140 r.p.m. Quiet 940 r.p.m. 880 r.p.m. 960 r.p.m. 1,030 r.p.m. 1,240 r.p.m. 1,030 r.p.m. 1,220 r.p.m. 1,140 r.p.m. High 550 m /h 600 m /h 650 m3/h 800 m3/h 940 m3/h Low Quiet High Medium Low 1,160 r.p.m. 1,000 r.p.m. 3 3 Medium Low 490 m3/h 550 m3/h 600 m3/h 700 m /h 880 m3/h 470 m3/h Quiet High 440 m3/h 500 m3/h 450 m3/h 550 m3/h 480 m3/h 600 m3/h 480 m3/h 820 m3/h 750 m3/h 600 m3/h 650 m3/h 800 m3/h 940 m3/h 550 m3/h 600 m3/h 700 m3/h 880 m3/h 500 m3/h 450 m3/h 550 m3/h 480 m3/h 600 m /h 480 m3/h 820 m3/h 750 m3/h 28 dB(A) 27 dB(A) 29 dB(A) 28 dB(A) 32 dB(A) 32 dB(A) 26 dB(A) 25 dB(A) 27 dB(A) 26 dB(A) 30 dB(A) 28 dB(A) 26 dB(A) 31 dB(A) 30 dB(A) 29 dB(A) 26 dB(A) 28 dB(A) 26 dB(A) 29 dB(A) 28 dB(A) 33 dB(A) 30 dB(A) 33 dB(A) 32 dB(A) 25 dB(A) 25 dB(A) 27 dB(A) 28 dB(A) 31 dB(A) 24 dB(A) 25 dB(A) 29 dB(A) Medium 550 m3/h 490 m3/h Low 470 m3/h Quiet 440 m3/h 28 dB(A) 26 dB(A) High Medium Low Quiet High Medium Low Quiet DIMENSIONS WEIGHT ARYG14LVTA 4.0 kW class MFG-14WV DISCRIMINATION MEASUREMENTS ARYG12LLTA 3.5 kW class HxWxD Net / Shipping 25 dB(A) 24 dB(A) 28 dB(A) 24 dB(A) 24 dB(A) 198 x 700 x 620 mm 19 kg / 25 kg 6 3 3 198 x 900 x 620 mm 23 kg / 29 kg INDOOR UNIT FLOOR / CEILING ELECTRICAL DATA MODEL NAME CAPACITY ABYG14LVTA 4.0 kW class FAN MOTOR MFH-24RVL DISCRIMINATION Cooling FAN SPEED Heating Cooling Heating Cooling NOISE LEVEL Heating DIMENSIONS WEIGHT 2011.01.25 High 1,380 r.p.m. 1,460 r.p.m. Medium 1,300 r.p.m. 1,360 r.p.m. Low Quiet High 1,220 r.p.m. 1,140 r.p.m. 1,380 r.p.m. 1,260 r.p.m. 1,180 r.p.m. 1,460 r.p.m. Medium 1,300 r.p.m. 1,360 r.p.m. Low Quiet 1,220 r.p.m. 1,140 r.p.m. 1,260 r.p.m. 1,180 r.p.m. High 940 m3/h 1330 m3/h Medium Low 880 m3/h 1240 m3/h 820 m3/h 750 m3/h 1100 m3/h 1030 m3/h 940 m3/h 1330 m3/h Medium 880 m3/h 1240 m3/h Low Quiet 820 m3/h 750 m3/h 1100 m3/h 1030 m3/h High 32 dB(A) 33 dB(A) Medium Low Quiet 31 dB(A) 30 dB(A) 29 dB(A) 32 dB(A) 30 dB(A) 29 dB(A) High Medium 33 dB(A) 32 dB(A) 35 dB(A) 34 dB(A) Low 31 dB(A) 32 dB(A) Quiet 29 dB(A) 29 dB(A) Quiet High AIR FLOW MEASUREMENTS ABYG18LVTA 5.00 kW class HxWxD Net / Shipping 199 x 990 x 655 mm 27 kg / 36 kg 7 650 154 Top view 48 410 51 : Gas DIMENSIONS OUTDOOR UNIT AOYG45LAT8 Unit : mm 40 24 370 43 : Liquid 166 36 24 370 12 970 Front view 3-1/2 (89) Pipe port Side view 14 15 50 40 50 76 278 438 526 622 690 2010.09.17 ø28 : Cable port Pipe port 65 Pipe & cable port Detail A 8 142 155 70 55 50 50 111 120 297 95 50 ø28 : Cable port 21 Bottom view 140 227 296 305 315 321 341 ø28 : Cable port 25 3-7/16 (87) 5-5/32 (131) 8 21 11 (279) 526 914 Terminal blocks 21 ø28 : Cable port 65 ø28 : Cable port Pipe port Rear view 214 174 BRANCH BOX UTP-PY03A 154 134 Unit : mm 176 216 110 256 469 Indoor unit side 95 75 433 195 Ceiling hanging Outdoor unit side 148 469 Wall hanging 2010.10.28 9 75 68 25 85 24 57 95 256 372 95 70 432 174 154 134 BRANCH BOX UTP-PY02A Unit : mm 110 176 216 469 372 85 68 Indoor unit side 24 75 152 95 256 95 70 432 75 433 195 Ceiling hanging Outdoor unit side 148 25 469 Wall hanging 2010.10.28 10 INDOOR UNIT COMPACT WALL MOUNTED ASYG07LJCA ASYG09LJCA ASYG12LJCA Unit : mm 205 : Installed state 790 280 203 10 145 *1 *1 140 *1 94 *1: Vertical flap is downward 18 450 Outline of unit 62 ø65 for pipe inlet 2010.09.17 237 323 209 327 184 47 47 82 52 78 353 : Gas pipe 415 : Liquid pipe 11 ø65 for pipe inlet 215 18 INDOOR UNIT WALL MOUNTED ASYG18LFCA ASYG24LFCA Unit : mm 320 998 520 590 238 721 122 170 172 130 75 133 126 18 x 11 hole 26 x 11 hole 21 x 5 : 14holes outline of UNIT 272 269 44 149 5 x 18 : 14holes 113 243 30 75 320 : Unit size 18 x 11 hole 400 197 16 Unit center 13 26 x 11 hole 20 439 387 12 37 30 438 ø80 hole Piping inlet ø80 hole Piping inlet 1000 : Unit size 5 x 50 : 3holes 2010.11.18 397 ø5 : 65holes for tapping screw 13 x 5 : 4holes 12 INDOOR UNIT COMPACT CASSETTE AUYG07LVLA AUYG09LVLA AUYG12LVLA AUYG14LVLA AUYG18LVLA Unit : mm • Decoration panel mounting state 250 Ceiling openings Top view Min. 450 135 150 to 200 75 540 : Hanging bolt position 530 : Hanging bolt position Maintenance space Be sure to leave maintenance space for future service at the designated position. Min. 450 40 99 102 Drain port 215 262 30 30 108 146 245 114 102 Drain port 58 Side view 700 2010.09.15 Bottom view 13 49 30 700 Ceiling 123 30 Side view INDOOR UNIT AGYG09LVCA AGYG12LVCA AGYG14LVCA unit : mm 740 600 200 2010.09.17 14 INDOOR UNIT SLIM DUCT ARYG07LLTA ARYG09LLTA ARYG12LLTA ARYG14LLTA Unit : mm 51 152 174 574 View A 71 Rear view (Drain hose) 620 371 264 69 10 144 377 30 Drain port 100 x 6 = 600 47 650 55 734 89 48 82 Top view 119 167 Side view 55 43 78 151 168 198 78 20 650 664 700 Front view Bottom view 2010.09.17 15 INDOOR UNIT SLIM DUCT ARYG18LLTA Unit : mm 51 71 152 174 774 Rear view View A 30 (Drain hose) 69 10 144 47 100 x 8 = 800 850 934 89 87 Top view 56 119 167 Side view 55 43 78 151 168 198 78 55 20 850 864 900 Front view Bottom view 2010.09.17 16 371 264 620 377 Drain port INDOOR UNIT ABYG14LVTA ABYG18LVTA 655 Unit : mm 990 199 Rear view 175 900 2010.09.17 17 530 200 500 BRANCH BOX 1 (primary type) OUTDOOR UNIT 3-way valve High pressure sensor switch Check valve TH10 TH10 Strainer High pressure sensor HEX TH11 TH1 TH2 Compressor TH3 HEX EEV3 Heat exchanger EEV1 Sub-cool heat exchanger Solenoid valve Low pressure sensor TH4 TH5 3-way valve Strainer EEV3 TH7 0 TH12 EEV3 Strainer TH9 EEV2 TH10 TH10 Strainer OUTDOOR UNIT TH11 HEX 0 TH12 TH11 HEX 0 TH12 TH11 Electric expansion valve Discharge temperature thermistor Compressor temperature thermistor Suction temperature themistor Outdoor temperature themistor Heat exchanger (outlet) thermistor Sub-cool heat exchanger (inlet) thermistor Sub-cool heat exchanger (outlet) thermistor Liquid temperature thermistor EEV4 HEX EEV3 Strainer INDOOR UNIT 4 INDOOR UNIT 5 INDOOR UNIT 6 0 TH12 TH9 Strainer Strainer EEV3 EEV3 TH9 Strainer TH9 BRANCH BOX 3 (secondary type) TH10 TH11 HEX 0 TH12 BRANCH BOX TH10 Electric expansion valve Branch box liquid temperature thermistor Branch box gas temperature thermistor TH10 Strainer INDOOR UNIT EEV3 Heat exchanger Heat exchanger (middle) thermistor Room temperature thermistor Strainer TH9 Strainer Strainer EEV3 EEV3 18 TH11 HEX 0 TH12 EEV4 HEX TH 11 TH 12 INDOOR UNIT 3 TH9 TH10 REFRIGERANT SYSTEM DIAGRAM INDOOR UNIT 2 Strainer Accumulator EEV TH 9 TH 10 INDOOR UNIT 1 TH9 TH8 Strainer TH6 Strainer BRANCH BOX 2 (secondary type) 2010.06.14 TH11 0 TH12 EEV4 Oil separator EEV TH 1 TH 2 TH 3 TH 4 TH 5 TH 6 TH 7 TH 8 HEX 0 TH12 TH10 Strainer 4-way valve TH11 TH9 Strainer TH9 INDOOR UNIT 7 INDOOR UNIT 8 PIPING LIMITATION a c b H2 e d H3 i l j k H1 h g f H4 m PIPE LENGTH Total pipe length Less than 115 m Total Between outdoor unit and the farthest indoor unit Less than 70 m a+b+c+m Between outdoor unit and branch boxes Less than 55 m a+b+c+d+e Total Less than 60 m f+g+h+i+j+k+l+m Each unit 3 to 15 m Between branch box and indoor unit f, g, h, i, j, k, l, m Between outdoor unit and the first separation tube More than 5 m a Between outdoor unit and branch box (When there is no separation tube) More than 5 m a+d Between outdoor unit and indoor unit Less than 30 m H1 Between outdoor unit and branch box Less than 30 m H2 Between branch boxes Less than 15 m H3 Between indoor units Less than 15 m H4 HEIGHT DIFFERENCE ADDITIONAL CHARGE Liquid pipe diameter Additional charge 6.35 mm 21 g/m 9.52 mm 58 g/m Additional refrigerant depends on the liquid pipe diameter. PIPE DIAMETER Branch box AOYG45LAT8 (Outdoor side) Liquid pipe 9.52 mm Gas pipe 15.88 mm 2010.10.28 Branch box (Indoor side) ASYG07,09,12LJCA ASYG18LFCA AUYG07,09,12LVLA AUYG14,18LVLA ARYG07,09,12LVCA ARYG18LLTA ASYG24LFCA 6.35 mm 12.7 mm 19 9.52 mm 12.7 mm 15.88 mm WHITE BLACK WHITE TERMINAL 2 3 L N TM501 W505 TM502 FILTER PCB ASSY POWER SOURCE TO BRANCH BOX 2010.10.27 GREEN W303 F501 AC250V 10A FUSE FUSE F502 AC250V 3.15A F503 AC250V 10A 1 2 1 2 W381 CN390 WHITE TM508 BLACK TM507 BLACK RED WHITE 3 3 CN501 2 2 1 1 CM C S 1 1 2 2 CN370 3 3 TM400 WHITE TM401 BLACK TM402 COMPRESSOR 20 CN281 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 1 2 3 4 5 CN380 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 CN320 7 6 5 CN172 4 3 2 1 BLUE GREEN YELLOW ORANGE RED BROWN 7 6 5 4 3 2 1 1 CN951 2 2 CN933 1 1 CN952 2 2 CN932 1 CN931 2 1 7 6 5 4 CN921 3 2 1 1 2 3 CN360 RED TM390 TM392 TM393 4 CN395 3 2 1 + BLACK TM391 INVERTER PCB ASSY 7 6 5 4 3 2 1 2 CN934 1 EXTERNAL I NPUT 1 2 3 1 2 3 CN66 INDICATOR, I/O PCB ASSY EXTERNAL OUTPUT BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK CN251 1 2 3 4 5 1 2 3 4 5 W380 RED R 1 2 3 4 1 2 3 4 CN65 BROWN RED ORANGE YELLOW GREEN BLUE VIOLET GRAY P501 AC500V 45A CN271 1 2 1 2 WHITE BLACK FUSE 1 2 3 4 5 1 2 3 4 5 CN63 1 2 3 4 1 2 3 4 CN62 YELLOW 1 2 3 1 2 3 CN61 CONTROLLER PCB ASSY ( MAIN PCB ) FUSE BLACK BLACK BLACK BLACK BLACK BLUE ORANGE YELLOW WHITE RED 1 2 3 4 5 6 1 2 3 4 5 6 CN112 BLUE 1 2 3 4 5 1 2 3 4 5 CN111 RED 1 2 1 2 CN101 OPTION ( CONNECTOR ) REFER TO THE TECHNICAL MANUAL THERMISTOR ( SUCTION TEMP. ) THERMISTOR ( SUBCOOL HIGH - OUT TEMP. ) THERMISTOR ( SUBCOOL LOW - I N TEMP. ) THERMISTOR ( SUBCOOL LOW - OUT TEMP. ) THERMISTOR ( PIPE - OUT TEMP. ) THERMISTOR ( DISCHARGE TEMP. ) THERMISTOR ( OUTDOOR TEMP. ) EXPANSION VALVE EV2 RED BLUE ORANGE YELLOW WHITE RED RED WHITE BLACK W504 W506 W507 RED WHITE BLACK RED BLACK BLACK 1 1 2 3 1 2 3 CN92 CN201 1 2 3 4 5 1 2 3 4 5 F201 AC250V 3.15A EV1 PS 1 2 3 4 1 2 3 4 CN91 RED BLACK WHITE YELLOW BROWN 1 2 3 4 5 6 7 1 2 3 4 5 6 7 CN243 WHITE FUSE 1 2 3 1 2 3 CN205 RED BLACK BLUE BLUE BLACK BLACK BLACK 1 2 1 2 CN203 EXPANSION VALVE FM PS 1 2 1 2 CN202 PRESSURE SWITCH FAN MOTOR PRESSURE SENSOR ( LOW ) OSV PRESSURE SENSOR ( HIGH ) SOLENOID COIL 4WV BELT HEATER 4-WAY VALVE OUTDOOR UNIT AOYG45LAT8 THERMISTOR ( INV. COMP. SHELL TEMP. ) CIRCUIT DIAGRAM 4 3 2 1 - ACTPM YELLOW P BLUE N RED WHITE BLACK 4 3 2 1 4 3 CN11 2 1 L1 L2 CHOKE COIL WHITE WHITE CONTROLLER PCB ASSEMBLY W102 WHITE W101 BLACK TERMINAL 1 2 3 CN105 4 5 POWER 3 VIOLET 1 2 3 4 5 N 2 WHITE L 1 OUTDOOR UNIT or BRANCH BOX I N TERMINAL BLACK GREEN W201 BLACK 1 W103 CN308 1 2 3 4 5 6 1 2 3 4 5 6 CN309 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 1 2 3 4 BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK RED THERMISTOR (LIQUID TEMP. ) - C 21 THERMISTOR (GAS TEMP. ) - C BRANCH BOX UTP-PY03A THERMISTOR (LIQUID TEMP. ) - B EXPANSION EXPANSION VALVE COIL B VALVE COIL D EXPANSION EXPANSION VALVE COIL A VALVE COIL C 2010.10.27 CN310 EV THERMISTOR (GAS TEMP. ) - B EV THERMISTOR (LIQUID TEMP. ) - A BLUE ORANGE YELLOW WHITE RED BLUE ORANGE YELLOW WHITE EV CN307 1 2 3 4 5 6 1 2 3 4 5 6 THERMISTOR (GAS TEMP. ) - A EV CN306 1 2 3 4 5 6 1 2 3 4 5 6 RED BLUE ORANGE YELLOW WHITE RED 3 CN305 1 2 3 4 5 6 1 2 3 4 5 6 BLUE ORANGE YELLOW WHITE 2 CENTRAL REMOTE CONTROL UNIT TERMINAL BLACK RED WHITE BLACK TERMINAL I NDOOR UNIT C 2 1 W104 1 1 2 2 CN304 3 3 TERMINAL 3 F103 AC250V 3.15A WHITE TERMINAL BLUE YELLOW I NDOOR UNIT B 2 FUSE 5 4 3 2 1 I NDOOR UNIT A 1 5 4 CN104 3 2 1 3 BLACK 2 FUSE 1 3 BRANCH BOX 2 ( OUT ) TERMINAL WHITE WHITE WHITE PINK F102 AC250V 3.15A BLACK RED F101 AC250V 10A 3 2 BROWN 1 2 3 4 CN102 5 6 7 2 WHITE 1 2 3 4 5 6 7 1 1 BRANCH BOX 1 ( OUT ) TERMINAL BLACK 3 FUSE CONTROLLER PCB ASSEMBLY W102 WHITE W101 BLACK TERMINAL 1 2 3 CN105 4 5 N 3 VIOLET 1 2 3 4 5 L 2 WHITE POWER 1 OUTDOOR UNIT or BRANCH BOX I N TERMINAL BLACK GREEN W201 FUSE F101 AC250V 10A WHITE W104 1 1 2 2 CN304 3 3 W103 CN308 1 2 3 4 5 6 1 2 3 4 5 6 CN309 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK RED EXPANSION VALVE COIL D BRANCH BOX UTP-PY02A 2010.10.27 22 THERMISTOR ( LIQUID TEMP. ) - B EXPANSION EXPANSION VALVE COIL A VALVE COIL B EV THERMISTOR ( GAS TEMP. ) - B EV THERMISTOR ( LIQUID TEMP. ) - A BLUE ORANGE YELLOW WHITE CN307 1 2 3 4 5 6 THERMISTOR ( GAS TEMP. ) - A EV CN306 1 2 3 4 5 6 1 2 3 4 5 6 RED BLUE ORANGE YELLOW WHITE RED 3 CN305 1 2 3 4 5 6 1 2 3 4 5 6 BLUE ORANGE YELLOW WHITE 2 BLACK BLACK CN310 1 2 3 4 RED WHITE BLACK TERMINAL 1 CENTRAL REMOTE CONTROL UNIT TERMINAL RED WHITE TERMINAL 3 F103 AC250V 3.15A 3 BLUE YELLOW 2 2 FUSE 5 4 3 2 1 1 WHITE 5 4 CN104 3 2 1 I NDOOR UNIT B 1 BRANCH BOX 2 ( OUT ) TERMINAL F102 AC250V 3.15A BLACK 3 3 FUSE 2 2 BROWN 1 2 3 4 CN102 5 6 7 1 WHITE 1 2 3 4 5 6 7 I NDOOR UNIT A 1 BRANCH BOX 1 ( OUT ) TERMINAL BLACK INDOOR UNIT COMPACT WALL MOUNTED ASYG07LJCA ASYG09LJCA ASYG12LJCA CN201 1 2 3 4 5 6 7 INDICATOR PCB ASSY FAN MOTOR FM TO COMMUNICATION BOARD ( OPTION ) 1 2 3 4 5 6 7 8 RED WHITE WHITE WHITE WHITE WHITE WHITE BLUE YELLOW WHITE BLACK RED CN8 1 2 3 4 5 6 7 1 2 3 4 5 6 1 2 3 4 5 1 2 3 4 5 RED ORANGE 1 2 CN4 3 4 1 2 3 4 BLACK 1 2 3 CN5 4 CN3 5 6 CONTROLLER 7 PCB ASSY ( MAIN PCB ) 1 2 3 CN7 4 5 6 1 2 CN6 3 4 5 M LOUVER BLUE BLACK BLACK BLACK THERMISTOR (PIPE TEMP. ) THERMISTOR (ROOM TEMP. ) TEST GREEN W4 RED WHITE BLACK CN1 1 2 3 4 5 1 2 3 4 5 YELLOW PINK THERMAL FUSE 102 EARTH TERMINAL 1 2 TERMINAL 2010.10.12 23 3 COMMUNICATION KIT UTY-XCBXZ1 The limitation is option of ASYG07, 09 and 12LJCA 8 TO CONTROLLER PCB ASSY WHITE COMMUNICATION PCB ASSY 8 8 7 7 7 6 6 6 WHITE 5 5 5 WHITE 4 4 4 WHITE 3 3 3 WHITE 2 2 2 1 WHITE 3 CN303 2 1 CN301 CN304 1 1 EX I N ( OPTION ) 2 EX OUT ( OPTION ) 1 CN305 1 2 3 4 5 REMOTE CONTROL UNIT ( OPTION ) 2010.09.16 24 CONTROLLER PCB ASSY ( MAIN PCB ) INDOOR UNIT WALL MOUNTED ASYG18LFCA ASYG24LFCA TEST 1 2 3 4 5 CN13 EX. OUT ( OPTION ) 2 CN16 1 EX. I N ( OPTION ) THERMISTOR ( PIPE TEMP. ) 1 2 3 CN10 4 3 5 2 CN14 6 1 1 2 3 4 5 6 6 5 4 CN8 3 2 1 6 5 4 3 2 1 6 5 4 CN5 3 2 1 6 5 4 3 2 1 BLACK BLACK 3 3 2 2 1 1 THERMISTOR ( ROOM TEMP. ) WHITE 2 CN3 1 RED BLACK 2 CN1 1 BLACK 5 4 3 CN6 2 1 REMOTE CONTROL ( OPTION ) INDICATOR PCB ASSY CN201 7 6 5 4 3 2 1 WHITE WHITE WHITE WHITE WHITE WHITE RED WHITE TERMINAL 2010.10.12 THERMAL FUSE 102 WHITE BLACK TM4 W5 TM2 1 2 3 25 F M FAN MOTOR RED BLUE PINK YELLOW M LOUVER ( DIFFUSER ) M LOUVER ( UP / DOWN ) M LOUVER ( RIGHT / LEFT ) ORANGE RED BLUE PINK YELLOW ORANGE RED BLUE PINK YELLOW ORANGE RED TM1 RED BLACK 7 5 5 6 4 4 5 CN2 3 3 4 CN11 2 2 3 1 1 2 1 7 6 5 4 3 2 1 BLUE YELLOW GREEN INDOOR UNIT COMPACT CASSETTE AUYG07LVLA AUYG09LVLA AUYG12LVLA AUYG14LVLA AUYG18LVLA M 1 2 3 4 5 1 2 3 4 5 RED ORANGE YELLOW PINK BLUE 1 2 3 4 5 M 1 2 3 4 5 1 2 3 4 5 RED ORANGE YELLOW PINK BLUE 1 2 3 4 5 BLACK BLACK 1 2 1 2 CN8 1 2 CN7 1 2 CN3 3 CN12 4 CONTROLLER 5 PCB ASSY RED CN102 E101 E102 1 2 3 2011.01.06 CN103 CN106 1 2 1 2 1 2 YELLOW YELLOW YELLOW WHITE BLACK EX I N ( OPTION ) BROWN GREEN FM 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 1 2 3 4 5 6 7 8 1 2 3 CN101 CN104 1 1 W105 2 2 CN105 W102 3 3 POWER SUPPLY W101 4 4 5 5 PCB ASSY 6 6 GREEN FAN MOTOR 1 2 3 4 5 6 7 8 1 2 3 4 5 6 1 1 ( MAIN PCB ) 2 2 3 3 CN11 CN13 4 4 5 5 6 7 1 1 2 2 CN9 1 3 3 CN14 2 3 1 CN6 1 CN10 2 CN4 CN1 2 1 2 3 4 5 6 7 8 1 2 3 1 2 3 4 5 6 7 8 1 2 3 GRAY GRAY GRAY GRAY GRAY GRAY GRAY GRAY FLOAT SWITCH 1 2 1 2 CN5 THERMISTOR ( ROOM TEMP. ) 1 2 3 4 5 6 7 BROWN RED ORANGE YELLOW WHITE BLUE PURPLE 1 2 3 RED WHITE BLACK 26 M 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 5 6 7 FRESH AIR ( OPTION ) INDICATOR PCB ASSY 1 2 3 TERMINAL WIRED REMOTE CONTROL ( OPTION ) GRAY GRAY GRAY LOUVER ( UP / DOWN ) THERMISTOR ( PIPE TEMP. ) BLACK BLACK EX OUT ( OPTION ) LOUVER ( RIGHT / LEFT ) GRAY GRAY RED WHITE BLACK 1 TERMINAL 2 3 DRAIN PUMP MOTOR INDICATOR PCB ASSY CONTROLLER PCB ASSY ( MAIN PCB ) ( DISPLAY PCB ASSY ) CN203 6 5 4 3 2 1 DAMPER LIMIT SWITCH ( OPEN ) DAMPER LIMIT SWITCH ( CLOSE ) BLUE 4 BLACK 3 BLUE 2 BLACK 1 WIRED REMOTE CONTROL UNIT ( OPTION ) FLASH 4 3 2 1 5 4 3 2 1 7 6 5 4 3 2 1 2 1 2 1 THERMAL FUSE 102 1 TERMINAL 2010.10.27 27 CN10 CN11 CN12 7 6 5 4 3 2 1 7 6 5 4 3 2 1 RED BLACK WHITE BLUE RED BLACK WHITE BLUE 6 5 4 3 2 1 BLUE 6 5 4 3 2 1 6 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1 3 2 1 2 1 3 F M DC FAN MOTOR ( LOWER ) YELLOW 6 5 4 3 2 1 3 2 1 F M DC FAN MOTOR ( UPPER ) YELLOW BLUE 3 2 1 2 6 5 4 3 2 1 5 4 3 2 1 TM5 TM1 TM2 WHITE BLACK 6 5 4 3 2 1 5 4 3 2 1 RED TEST 5 4 3 2 1 CN8 CN1 BLACK CN5 CN3 2 1 BLACK CN2 2 2 1 1 CN13 GRAY CN18 GRAY RED CN14 WHITE WHITE CN15 WHITE WHITE CN16 WHITE 1 2 3 4 5 6 7 8 9 CN20 WHITE 1 2 3 4 5 6 7 8 9 CN6 THERMISTOR ( ROOM TEMP. ) WHITE WHITE CN9 THERMISTOR ( PIPE TEMP. ) 9 8 7 6 5 4 3 2 1 CN21 CN22 ( SWITCH PCB ASSY ) CN201 1 2 3 4 5 6 CN202 CN17 INDOOR UNIT FLOOR AGYG09LVCA AGYG12LVCA AGYG14LVCA PINK M DAMPER LOCK ( LEFT ) M DAMPER LOCK ( RIGHT ) M LOUVER ( UP / DOWN ) M DAMPER YELLOW ORANGE RED PINK YELLOW ORANGE RED BLUE PINK YELLOW ORANGE RED BLUE PINK YELLOW ORANGE RED EX I NPUT ( OPTION ) EX OUTPUT ( OPTION ) GRAY GRAY INDOOR UNIT SLIM DUCT ARYG07LLTA ARYG09LLTA ARYG12LLTA ARYG14LLTA ARYG18LLTA BLACK BLACK 1 2 1 2 CN5 1 2 3 CN12 4 5 LOUVER ( OPTION ) FLOAT SWITCH 1 2 1 2 CN8 1 2 CN7 1 CN10 2 CN6 1 2 CN1 1 2 3 1 2 3 4 4 5 5 RED 6 6 GRAY GRAY GRAY GRAY GRAY GRAY GRAY GRAY GRAY GRAY GRAY CN4 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 BROWN 1 1 YELLOW 2 2 WHITE 3 3 CN105 BLACK 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 CN104 1 2 3 1 2 3 CN101 POWER SUPPLY PCB ASSY FRESH AIR ( OPTION ) 1 2 CN108 1 2 3 1 2 3 M REACTOR DRAIN PUMP MOTOR 2010.10.12 28 1 2 3 TO REMOTE CONTROL WHITE YELLOW YELLOW GREEN GREEN CN102 CN106 E101 E102 E103 1 2 3 1 2 1 2 TERMINAL W105 RED WHITE W102 BLACK W101 CN103 GREEN INDICATOR PCB ASSY ( OPTION ) 1 1 RED CN14 2 2 WHITE 3 3 BLACK WHITE FM 1 2 3 CN3 4 5 6 2 3 CN13 4 5 6 7 2 3 CN11 4 5 1 1 2 2 CN9 BLACK 3 3 HEATER ( OPTION ) THERMISTOR ( ROOM TEMP. ) CONTROLLER PCB ASSY 1 1 ( MAIN PCB ) BLACK FAN MOTOR THERMISTOR ( PIPE TEMP. ) 1 TERMINAL 2 3 TO OUTDOOR UNIT INDOOR UNIT FLOOR / CEILING ABYG14LVTA ABYG18LVTA LOUVER ( RIGHT / LEFT ) LOUVER ( UP / DOWN ) BLACK BLACK 1 2 1 2 CN5 1 1 2 2 1 2 1 2 CN8 1 2 CN7 M 1 2 3 4 5 1 2 3 4 5 BROWN RED ORANGE YELLOW WHITE 1 2 3 4 5 1 2 CN3 3 CN12 4 5 CONTROLLER M 1 2 3 4 5 1 2 3 4 5 BROWN RED ORANGE YELLOW WHITE 1 2 3 4 5 1 ( 2 3 CN11 4 5 PCB ASSY MAIN PCB ) 1 2 CN9 3 2010.10.15 1 2 3 CN13 4 5 6 7 GRAY GRAY GRAY GRAY GRAY GRAY GRAY GRAY GRAY GRAY GRAY EX OUT ( OPTION ) EX I N ( OPTION ) RED GREEN GREEN / YELLOW 1 2 3 4 5 6 1 2 3 4 5 6 7 29 RED ORANGE YELLOW WHITE BLUE PURPLE GRAY 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 INDICATOR PCB ASSY RED WHITE BLACK TERMINAL 1 2 3 WIRED REMOTE CONTROL UNIT ( OPTION ) 1 2 3 4 5 6 7 8 1 2 3 1 2 3 4 5 6 7 8 1 2 3 CN104 CN101 1 1 W105 2 2 CN105 3 3 POWER SUPPLY W102 W101 4 4 PCB ASSY 5 5 6 6 CN102 CN103 CN106 E101 E102 1 2 3 1 2 1 2 GREEN FAN MOTOR F M BROWN YELLOW WHITE BLACK THERMISTOR ( ROOM TEMP. ) CN6 1 CN1 2 1 2 3 1 2 3 CN4 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 THERMISTOR ( PIPE TEMP. ) BLACK BLACK 1 1 CN14 2 2 3 3 1 CN10 2 1 2 3 4 5 6 7 8 GRAY GRAY TERMINAL RED WHITE BLACK 1 2 3 4-WAY VALVE SOLENOID VALVE 1 2 3 L1 W505 N-OUT1 UL1015 AWG10 TM505 BLACK F501 AC250V 10A TM506 TM501 L-I N 1 W506 L-OUT2 UL1015 AWG20 BLACK W507 N-OUT2 UL1015 AWG20 WHITE UL1015 AWG20 RED FILTER PCB ASSEMBLY K09CR-1000HUE-FL0 PRIMARY TM502 N-I N CN501 2-1871843-3 BLUE 3 1 2 CN203 2-1747052-3 3 1 CN205 B2P3-VH-B-E BLUE BLACK WHITE YELLOW BROWN AWG22 AWG22 AWG22 AWG22 UL3266 UL3266 UL3266 UL3266 1 4 7 CN243 B5 ( 7-2.3 ) B-XASK-1-A CN206 B4P-VH-B-C BLUE RED BLUE UL1015 AWG20 1 WHITE BLACK 1 CN201 B3P5-VH-B WHITE 1 5 CN91 1871843-4 F201 AC250V 3.15A WHITE CN92 1-1871843-3 SECONDARY L-OUT WHITE TM508 UL1015 AWG10 WHITE AC IN L2 2 CN202 1747052-1 F502 AC250V 3.15A F503 AC250V 10A L-OUT POWER SOURCE AC230V 50Hz W504 L-OUT1 WHITE UL1015 AWG16 P501 AC500VBL1030A 45A TM507 TO BRANCH BOX BLACK BASE HEATER UL3266 AWG22 BLUE UL1015 AWG20 1 UL1015 AWG16 BLACK BLACK BLACK INVERTER ASSEMBLY EZ-010SHUE AOYG45LAT8 F. M. SV UL3478 AWG20 UL3478 AWG20 4WV DC FAN MOTOR CRANKCASE HEATER ( BELT HEATER ) BLACK OUTDOOR PCB CIRCUIT DIAGRAM RED W503 E CN101 1-1871843-2 UL1015 AWG16 RED GREEN CHOKE COIL TTFG08904-1 30A 0.7MH PP P (-) UL1015 AWG10 UL1015 AWG10 RED BLACK N UL1015 AWG10 YELLOW CN111 B05B-XARK-1-A RED 6 1 WHITE CN11 292175-4 UL1015 AWG10 BLUE PRIMARY UL1430 AWG26 x3 SECONDARY 1 CN61 B03B-PASK-1 N NC TM397 W393 P NC TM396 W392 NC TM395 NC (-) TM391 TM394 NC (+) TM390 TM383 N-IN NC W381 L-IN 1 TM382 W380 WHITE 4 1 CN395 B04B-PAKK-1 BLACK CN390 B02B-XASK-1-A CN370 2-1871843-3 WHITE 1 18V UL1430 AWG26 UL1430 AWG26 WHITE BLACK 2 1 CN271 B02B-XASK-1-A WHITE 4 WHITE 2 1 BLUE CN380 B3P5-VH-B-C BLACK 5 CN320 B08B-PASK-1 1 TEST 1 WHITE F380 DC400V 5.0A 8 VDC (DC FAN) UL1430 AWG20 RED UL1430 AWG20 BLUE UL1015 AWG20 YELLOW MAIN - INV. COM. UL1430 UL1430 UL1430 UL1430 UL1430 UL1430 UL1430 UL1430 AWG26 AWG26 AWG26 AWG26 AWG26 AWG26 AWG26 AWG26 BROWN RED ORANGE YELLOW GREEN BLUE VIOLET GRAY CN63 B05B-PASK-1 1 WHITE CN251 B3P5-VH-B-C BLACK UL3271 AWG10 COMPRESSOR C. M. RED U TM400 WHITE 1 WHITE 4 CN281 B08B-PASK-1 WHITE V TM401 W TM402 CN172 B07B-PASK-1 1 1 CN360 B03B-PAKK-1 2 SECONDARY UL1430 AWG26 x6 FLASH 7 INDICATOR, I / O PCB ASSEMBLY K09BI-1000HUE-C1 WHITE CN932 CN934 CN931 CN933 B02B-XAYK B02B-XAMK B02B-XASK B02B-XARK -1-A -1-A -1-A -1-A CN901 B06B-PASK -1 6 FLASH 30 GREEN YELLOW WHITE 1 2010.09.16 3 6 MAIN-INDICATOR,I/O PCB COM. CN921 B07B-PASK-1 UL3271 AWG10 BLACK 1 1 2 EX I N1 1 RED WHITE 2 EX I N2 1 1 WHITE WHITE 7 1 CN66 B03B-XASK-1-A CN1 B06B-PASK-1 WHITE 8 BROWN RED ORANGE INVERTER PCB ASSEMBLY K09CQ-1000HUE-TR1 BLACK UL3271 AWG10 1 CN65 B04B-XASK-1-A 5 WHITE 6 RED WHITE BLACK PRES. SENSOR LO PRESSURE SENSOR ( LO PRESSURE ) UL1430 AWG22 UL1430 AWG22 RED RED AWG26 AWG26 AWG26 AWG26 AWG26 RED BLUE ORANGE YELLOW WHITE AWG26 RED AWG26 AWG26 AWG26 AWG26 BLUE ORANGE YELLOW WHITE PRES. SW DC PRESSURE SWITCH EEV 1 ELECTRIC EXPANSION VALVE 1 EEV 2 ELECTRIC EXPANSION VALVE 2 BLACK BLACK TH1 NO MARKING BLACK BLACK TH1 BROWN BLACK BLACK TH2 GRAY THERMISTOR ( INVERTER COMP. SHELL TEMP. ) BLACK BLACK TH1 RED THERMISTOR ( PIPE - OUT TEMP. ) BLACK BLACK TH2 NO MARKING BLACK BLACK TH1 BLUE BLACK BLACK TH2 YELLOW BLACK BLACK TH1 WHITE THERMISTOR ( OUTDOOR TEMP. ) THERMISTOR ( DISCHARGE TEMP. ) THERMISTOR ( SUBCOOL LO - OUT TEMP. ) 5 YELLOW GREEN BLUE 1 CN350 B06B-PASK-1 3 1 CN62 B04B-PASK-1 3 PRIMARY PRESSURE SENSOR ( H I PRESSURE ) 6 1 4 BLACK WHITE UL1015 AWG10 (+) CONTROLLER PCB ASSEMBLY ( MAIN PCB ) K09CM-1000HUE-C1 PRES. SENSOR HI 2 CN112 B06B-XASK-1-A RED BLACK UL1015 AWG10 ACTPM 30A (PM-703BSG) 3 1 1 L2 WHITE BLACK RED WHITE UL1430 AWG26 UL1430 AWG26 UL1430 AWG26 L1 3 1 RED WHITE BLACK 2 EX I N3 1 2 EX I N4 CN951 CN952 B02B-XAKK B02B-XAEK -1-A -1-A BLACK 1 BLUE 2 EX OUT1 1 2 EX OUT2 THERMISTOR ( SUBCOOL LO - I N TEMP. ) THERMISTOR ( SUBCOOL H I - OUT TEMP. ) THERMISTOR ( SUCTION TEMP. ) OUTDOOR UNIT AOYG45LAT8 CONTROLLER PCB ASSEMBLY ( MAIN PCB ) : PRIMAY K09CM-1000HUE-C1 R121 5V 330 Q121 DTC124EUA <1/10W> 3 2 P_FM1_PWM L291 BLm31PG121 C292, C293 R293 180 330p x 2 <1/4W> AC I N I C211 TOP258PN 8 S D 4 7 S 6 S 5 S C 2 M 1 D211 ST03D-82 R214 9V 10k <1/10W> C213 0.1 4-WAY VALVE CN202 1747052-1 WHITE 2 CR202 RE1201 1 SOLENOID VALVE CN203 2-1747052-3 BLUE 2 BLUE 1 2 4 3 1 K202 G5NB-1A I C126-1 uLN2003 16 1 + 10 11 12 13 14 3 2 3 2 16 17 1 13 14 1 15 2 4 3 1 K203 G5NB-1A 2 L151 BLm31PG121 A P_4WV PC202 PS2561L-1-V P_SV1 CR205 RE1201 2 4 3 1 K205 G5NB-1A 1 2 4 1 50V P_FM2_FB C122 10k <1/10W> -10V L153 BL02Rn2 12V + C151 470/ 25V R160 10 <1/4W> + C152 100/ 50V D153, D154 RD3.6FM x 2 L154 2.2uF + C155 0.1 R159 10k <1/10W> L155 2.2uH C166 1000/ 25V F151 1.1A - 16V + 2 3 4 3 1 G/V K206 G5NB-1A 5 R155 R157 3.0k 2.7k <1/10W> <1/10W> 1% 1% I C126-8 uLN2003 23V JM273 0R0 JM130 0R0 5V-2 15V 15V-3 C242 + 47/ 35V O 3 G 2 C279 1 +C276 10/ 50V 0.1 D281 1SS355 JM283 0R0 C282 0.33 1 A 2 C280 0.1 1 3 R141 47k <1/10W> HYIC201 HU2001R3 5 4 3 2 1 5 4 3 2 1 3 1 Q142 2SC2412K 2 R144 1.0k <1/10W> 5V I C126-7 uLN2003 10 7 PC207 PS2561L-1-V R289 2.2k <1/10W> 3 PC208 2 PS2561L-1-V R290 2.2k <1/10W> C289 R292 1000p 330 <1/10W> 1 4 5V R142 4.7k <1/10W> R140 27k <1/10W> -10V R143 1.0k <1/10W> C142 0.01 C141 0.1 P_SER I AL_RXD P_I NT_POWER P_SER I AL_TXD P_RXD_I NV P_LOW_VOLTAGE P_TXD_I NV 31 4 1 3 2 4 1 R147 R145 C145 1.0k 1.0k 0.01 <1/10W> <1/10W> C146 R148 R146 0.01 1.0k 1.0k <1/10W> <1/10W> 2 Q145 DTC124EUA 3 1 R150 330 <1/10W> C147 1000p R149 2.2k <1/10W> 2 PC209 3 PS2561L-1-V WHITE L275 DLW31Sn102SQ2 I C281 BAJ5CC0T C283 0.1 +C284 10/ 50V MA I N - I NV COM. CN281 B08B-PASK-1 15V-2 WHITE 1 2 3 5 C287 0.1 JM288 0R0 C288 R291 1000p 330 <1/10W> 18V CN271 B02B-XASK-1-A 2 4 P_BH BLACK 18V I C272 BA17818 1 3 2 5V 10 6 1 I 3 VDC ( DC FAN MOTOR ) CN251 B3P5-VH-B-C 2 D272 1SS355 C278 0.33 340V-2 D204 D3SB60 D P I N1, P I N2 I PS-1124 x 2 14 7 R274 - R276 6.8k <1/4W> x3 C136 0.1 JM206 18 8 2 R249 4.7 A R165 100k <1/10W> 1% 8 I C126-5 uLN2003 12 3 D VCC 4 1 A R158 10k <1/10W> A 2 340V 4 C154 1000/ 25V C 3 REF 1 5V 4 9 2 3 D P_CCH CR206 RE1201 2 7 I C126-4 uLN2003 13 1 A 12V BASE HEATER CN206 B4P-VH-B-C 2010.09.16 C160 + I C151 10/ TL431A I 50V WHITE R245 6.8k <1/4W> 6 C153 1000/ 25V C159 1.0 DC FAN MOTOR CN243 B5 ( 7-2.3 ) B-XASK-1-A A 5 R232 100k <1/10W> 1% C232 + 100/ D151 RF601T2D R152 330 <1/4W> C245 + 10/ 50V R243 8.2k <1/10W> 1% 4 1% 3 2 R231 33k <1/4W> D232 RF101L2S + C164, C165 R162 330p x 2 180 <1/10W> R153 C156 R154 100 1.0 2.7k <1/10W> <1/10W> 4 5V BLACK + C231 220/ 35V 2 D152 RB160M-60 1 R247 4.7k <1/10W> 1 3 R213 330 <1/4W> 2 18 4 3 A 15V R161 C162, C163 180 330p x 2 <1/4W> C216 10/ 50V I C126-2 uLN2003 15 L232 BLm31PG121 L211 BLm31PG121 CR203 RE1201 1 CRANKCASE HEATER CN205 B2P3-VH-B-E + R211 C212 6.8 47/ <1/4W> 35V 12V 8 9 10 11 12 6 5 R212 C220, C219 180 <1/10W> 330p x 2 D213 RF101L2S 7 6 5 4 8 7 PC242 PS2561L-1-V R241 10k <1/10W> 1% R294 33k <1/4W> D231 RF301B2S R234 C235, C236 180 330p x 2 <1/4W> T201 EK2923DT C121 1000p 340V-2 C243 0.1 D243 PTZ24B D C233, C234 R233 180 330p x 2 <1/4W> R223, R224 22 <1/4W> x2 + C211 33/ 450V C291 100/ 50V L241 BLm18AG601 GND 3 R215 - R218 1.0M <1/4W> x4 FH201 FH202 TP00351-31 x2 L231 BLm31PG121 3 OUT 1 R219, R220 470 <1/4W> x2 C214 2200p 2 VCC WHITE 2 VA201 470V F201 3.15A 250V 4 23V + 340V CN201 B3P5-VH-B D291 UF4005 15V-3 1 R123 R125 10k 1.0k <1/10W> <1/10W> 1 P_FM1_FB PC241 PS2561L-1-V 6 7 8 -10V-2 OUTDOOR UNIT AOYG45LAT8 CONTROLLER PCB ASSEMBLY ( MAIN PCB ) : SECONDARY K09CM-0900HUE-C1 5V THERMISTOR ( OUTDOOR TEMP. ) CN61 B03B-PASK-1 1 2 3 R61 38.3k <1/10W> 1% THERMISTOR ( DISCHARGE / COMP. TEMP. ) CN62 B04B-PASK-1 WHITE P_AN_TH1 OUTDOOR C72 0.1 R72 10k <1/10W> R73 10k <1/10W> 1 2 P_AN_TH2 DISCHARGE 3 4 R62 13k <1/10W> 1% THERMISTOR ( SC LOW PIPE OUT / PIPE OUT TEMP. ) R63 13k <1/10W> 1% R74 10k <1/10W> C73 0.1 P_AN_TH3 COMP C74 0.1 CN63 B05B-PASK-1 WHITE 1 3 4 5 THERMISTOR ( SC H I PIPE OUT / SC LOW PIPE I N TEMP. ) CN65 B04B-XASK-1-A WHITE 1 P_AN_TH4 P I PE ( OUT ) C75 0.1 R76 10k <1/10W> P_AN_TH5 SC-AN-TH5 or P I PE ( M I D ) C76 0.1 2 R66 4.75k <1/10W> 1% 3 R77 10k <1/10W> CN66 B03B-XASK-1-A MODE RESET P_AN_TH3 P_AN_TH4 P_AN_TH5 P_AN_TH6 P_AN_TH7 P_AN_TH8 P_AN_PS_HP P_AN_PS_LP P_I NT_POWER P_SERIAL_RXD P_SW_PD P_TXD_I O P_RXD_I O P_4WV P_FM1_PWM P_AN_TH6 SC_LP_I N EPV ( COOL ) C77 0.1 P_CCH P_BH P_FM2_FB P_D I PSW1 P_MA I N_STATE P_15VCUT P_FM1_FB R67 4.75k <1/10W> 1% THERMISTOR ( SUCTION TEMP. ) C3 0.1 P_SV1 R65 4.75k <1/10W> 1% 4 WHITE R75 10k <1/10W> R64 4.75k <1/10W> 1% 2 C1 100/ 25V + L1 0R0 L61 BLm18AG601 WHITE R78 10k <1/10W> 1 6 9 11 75 77 66 67 68 69 70 73 74 76 57 56 55 54 34 33 32 31 30 29 28 27 26 25 24 23 51 50 53 2 80 52 79 7 8 44 IC1 R5F212C P3_3 MODE RESET* VSS VSS VREF P0_0 P0_1 P0_2 P0_3 P0_4 P0_5 P0_6 P0_7 P1_0 P1_1 P1_2 P1_3 P1_4 P1_5 P1_6 P1_7 P2_0 P2_1 P2_2 P2_3 P2_4 P2_5 P2_6 P2_7 P3_0 P3_1 P3_2 P3_4 P3_5 P3_6 P3_7 P4_3 P4_4 P4_5 VCC VCC P4_6 P4_7 P5_0 P5_1 P5_2 P5_3 P5_4 P5_5 P5_6 P5_7 P6_0 P6_1 P6_2 P6_3 P6_4 P6_5 P6_6 P6_7 P7_0 P7_1 P7_2 P7_3 P7_4 P7_5 P7_6 P7_7 P8_0 P8_1 P8_2 P8_3 P8_4 P8_5 P8_6 P8_7 P9_0 P9_3 P9_2 P9_1 13 78 12 10 18 17 16 15 14 5 4 3 43 72 71 49 48 47 45 46 65 64 63 62 61 60 59 58 42 41 40 39 38 37 36 35 22 19 20 21 P_SW_PD P_D I PSW1 P_D I PSW2 C2 0.1 P_D I PSW3 1 3 2 EEP_SK EEP_CS EEP_I O X1 8.00MHz P_D I PSW4 C41 - C45 10k <1/10W> x 5 P_D I PSW4 P_D I PSW3 P_D I PSW2 P_PSW P_TXD_I NV P_RXD_I NV P_SERIAL_TXD P_TXD_PCS P_RXD_PCS P_AN_TH2 P_AN_TH1 MAIN - INDICATOR, I / O PCB COM. C60 + 10/ 50V R79 10k <1/10W> 7 P_MA I N_STATE R27 10k <1/10W> RESET MODE I C21 M93C66 CN91 1871843-4 WHITE 1 1 2 3 4 PRESSURE SENSOR ( LOW ) 2 3 C93 1000p C91 0.1 5V-2 CN92 1-1871843-3 1 1 3 2 3 C94 1000p C92 0.1 R22 10k <1/10W> R93 10k <1/10W> R91 10k <1/10W> D92 DAN217U RED 2 EEP_CS EEP_I O EEP_SK D91 DAN217U 5V-2 C95 0.01 P_AN_PS_HP 1 CS VCC DO 3 DI 2 SK NC 5 GND TEST R24 10k <1/10W> C28 0.1 5V R176 1.0k <1/10W> C171, C172 0.1 x 2 I C26 S80842 2 VDD 1 OUT C26 0.1 R34 1.0k <1/10W> NC 3 GND 4 FLASH 5V CN1 B06B-PASK-1 R31 - R33 10k <1/10W> x 3 WHITE R35 1.0k <1/10W> 1 2 3 4 5 P_RXD_PCS 6 P_TXD_PCS 8 4 7 6 C31 1000p C32 1000p C21 0.1 EEV-1 P_EEV ( MA I N )_P4 P_EEV ( MA I N )_P3 P_EEV ( MA I N )_P1 C96 0.01 C174 1000p R26 47k <1/10W> P_EEV ( MA I N )_P2 R94 10k <1/10W> R92 10k <1/10W> R175 330 <1/10W> C173 1000p 5V 5V PRESSURE SENSOR ( H I ) 5 6 P_LOW_VOLTAGE P_AN_TH8 SUCTION C79 0.1 4 P_TXD_I O 2 R68 4.75k <1/10W> 1% 3 R171 - R173 47k <1/10W> x 3 P_RXD_I O 1 3 WHITE 1 2 R174 1.0k <1/10W> P_AN_TH7 SC_HP_OUT EPV ( HEAT ) C78 0.1 5V 12V 5V P_EEV ( MA I N )_P1 P_EEV ( MA I N )_P2 P_EEV ( MA I N )_P3 P_EEV ( MA I N )_P4 P_EEV ( SUB )_P1 P_EEV ( SUB )_P2 P_EEV ( SUB )_P3 P_EEV ( SUB )_P4 CN172 B07B-PASK-1 I C111-1 uLN2003 1 16 I C112-1 uLN2003 1 16 I C111-2 uLN2003 2 15 I C112-2 uLN2003 2 15 CN111 B05B-XARK-1-A 12V RED 1 2 3 4 5 P_AN_PS_LP PRESSURE SWITCH EEV-2 CN112 B06B-XASK-1-A 12V CN101 1-1871843-2 RED 1 2 L91 BLm18AG601 R101 2.2k <1/10W> 5V-2 C101 0.1 P_EEV ( SUB )_P4 R102 10k <1/10W> P_EEV ( SUB )_P3 C102 0.01 P_PSW P_EEV ( SUB )_P2 P_EEV ( SUB )_P1 WHITE I C111-3 uLN2003 3 14 I C112-3 uLN2003 3 14 I C111-4 uLN2003 4 13 4 I C112-4 uLN2003 4 13 6 1 2 3 5 12V 9 VCC G/V 8 2010.10.12 32 9 I C112-8 uLN2003 VCC G/V 8 I C111-8 uLN2003 OUTDOOR UNIT AOYG45LAT8 R385 3.3 <3.8W> R386 6.8 <10W> D380 D25XB60 JM386 JM385 W380 L-I N 12V-2 POWER SOURCE AC230V 50Hz 4 3 2 1 2 + 1 3 - 4 F4100D + 2 + 1 3 - 4 W392 P TM390 R380 220k <2W> ACTPM TM391 D381 D25XB60 C380 - C384 660/450V x 5 + 380V + + C401 100/ 25V D400 ZP1027-TP W381 I 2 18V 2 4 1 3 2 PH395 PS2561L-1-V 4 R396 2.2k <1/10W> 15V-2 I C326 NJM7812 ACTPM DRIVE C326 + 47/ 35V 1 I C321 0.1 1 2 CN320 B08B-PASK-1 C322 + 330/ 35V 2 + C329 100/ 25V C328 0.1 I C307 S-93C66B0 I 5V-2 R308 1.0k <1/10W> O 3 Q321 DTC143EUA 3 2 L360 BLM21AG601 D D P_MAIN_SO2 P_MAIN_S I P_S I P_SO P_SCK P_UP P_UN P_VP P_VN P_WP P_WN P_AN_I L P_AN_OT P_AN_DC P_AN_CT P_AN_HT D 2 3 1 P_RTR I P P_TR I P P_MAIN_SO2 P_CP_POS P_TEST_SO P_TEST_S I C334 0.01 R333 1.0k <1/10W> 5V-2 P_MAIN_SO1 R334 1.0k <1/10W> P_AN_HT D R360 1.5k <1/10W> 1% R361 10k <1/10W> D L370 BLM21AG601 5V-2 3 R372 22k <1/10W> C370 0.1 C361 0.1 D R373 10k <1/10W> 2 D D C373 0.01 P_AN_CT D 2 CN350 B06B-PASK-1 D R351 10k <1/10W> D 2010.09.16 P_SCK P_S I P_SO RESET_I N RESET_OUT P_FLMD0 P_FLMD1 P_TEST_S I 6 C303 0.1 P_MAIN_SO1 P_MAIN_S I + C302 4.7/ 50V R342 - R345 10k <1/10W> x 4 P_TEST_SO D 5V-2 C310 0.1 VDD 2 3 NC 4 GND OUT 1 TM401 F4100D I TM402 F4100D W R471 2.2k <1/10W> 1% I C470-1 BA2903F 2 3 - 1 + 15V-2 VCC I C470-3 BA2903F 8 C470, C471 0.1 x2 G/V D484 RB751V I C470-2 BA2903F 7 6 + 5 - D I C480-3 BA4560RF R482 33k <1/10W> 1% VCC C480, C481 0.1 x2 G/V 4 D -10V D I C480-1 BA4560RF - 2 1 -10V P_AN_I L P_PR P_AF_EN I C471 TL431A I 15V-2 4 C485 1000p REF 1 A 2 D 8 D C 3 C473 1000p R470 0R0 <1/10W> R362 10k <1/10W> D362 1SS355 R485 1.0k <1/10W> D P_LED1 U 5V-2 D C362 0.1 D485 1SS355 D + 3 R484 22k <1/10W> D R483 33k <1/10W> 1% 15V-2 P_HS P_RUSH_R R480, R481 2.2k <1/10W> 1% x 2 D 5V-2 P_E2P_D I P_E2P_SK P_E2P_CS P_FLMD1 5V-3 P_FLMD0 C305 C304 + 0.1 4.7/ 50V P_RESET R300 10k <1/10W> R495 10k <1/10W> 3 1 2 D P_RTR I P C306 0.1 D R311 22k <1/10W> D 15V-2 D P_AN_DC I C310 S-80842CNNB D RESET_OUT RESET_I N C313 1000p C450 0.1 VCC G/V 4 C311 1000p R496 1.0k <1/10W> + C451 4.7/ 50V R427 1.0k <1/10W> C427 0.1 D 33 I C480-2 BA4560RF R491 R493 3.3k 2.7k <1/10W> <1/10W> 1% D 1% - 7 2 + D 1 3 D427 DAN217U U W V R430 R438 R442 R446 R431 R439 R443 R447 R432 R440 R444 R448 R433 R441 R445 R449 6 5 R434 6.8k <1/10W> 1% D 15V-2 5V-2 D R454 1.0k <1/10W> P_CP_POS P_RESET R313 1.0k <1/10W> + 380V 5V-2 D X300 8.0MHz R310 10k <1/10W> C496 1000p R492 R490 10k 10k <1/10W> <1/10W> 1% 1% I C450-2 BA2903F - 65 7 D 5V-2 P_HS P_FLMD0 5 4 33 36 37 42 43 44 38 39 40 41 45 46 47 48 49 50 51 52 53 54 1 3 5 7 8 9 10 11 2 32 6 I C450-3 BA2903F RESET_I N 4 VDD EVDD P90 P91 P913 P914 P915 P96 P97 P98 P99 PCM0 PCM1 PDL0 PDL1 PDL2 PDL3 PDL4 PDL5 PDL6 PDL7 AVREF0 FLMD0 REGC X1 X2 RESET* XT1 XT2 AVSS EVSS VSS F4100D V C406 0.022 R476 R477 10k 1.0k <1/10W> <1/10W> 5V-2 5V-2 R350 10k <1/10W> 3 L300 BLM21AG601 8 5V-2 5V-2 P00 P01 P02 P03 P04 P05 P06 P30 P31 P32 P33 P34 P35 P40 P41 P42 P50 P51 P52 P53 P54 P55 P70 P71 P72 P73 P74 P75 P76 P77 P78 P79 C477 0.01 P_AN_OT + C300 4.7/ 50V C301 0.1 D R340, R341 10k <1/10W> x 2 1 12 13 14 15 16 17 18 22 23 24 25 26 27 19 20 21 28 29 30 31 34 35 64 63 62 61 60 59 58 57 56 55 P_MODEL1 P_MODEL0 D 5V-2 5V-3 TM400 R474 22k <1/10W> I 5V-2 P_TR I P D I 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 D475 RB751V FH381, FH382 TP00351-31 x2 I C420 - C425 1000p x 6 C307 0.1 R307 D 10k <1/10W> D + C325 100/ 25V 2 1 I VNC VOT CIN CFO FO UN VN WN NW NV NU W V U P C475 330p 3 15V-2 5V-2 VCC 8 CS DI DO 4 SK NC 7 GND TEST 6 I C300 uPD70F3747 Q320 DTC143EUA 1 C360 0.1 1 3 2 5 P_E2P_CS P_E2P_D I P_E2P_SK D C324 0.1 I UP VP1 VUFB VUFS VP VP1 VVFB VVFS WP VP1 VPC VWFB VWFS VSC VN1 R420 - R425 330 <1/10W> x 6 3 1 D I C402 - C405 0.22 x 4 P_UP P_VP P_WP P_UN P_VN P_WN P_MODEL0 P_MODEL1 D 5 8 W D 4 7 CN370 2-1871843-3 C323 0.1 E R303, R304 10k <1/10W> x 2 P_RUSH_R P_LED1 P_AF_EN P_PR -10V 6 CN360 B03B-PAKK-1 G COM 2B 3B 4B 5B 6B 7B C417 C413 + 0.22 47/ 35V D417 D413 R413 O 3 2 D322 1SS355 1 I 2C 3C 4C 5C 6C 7C 2 3 4 5 6 7 8 12V-2 R319 330k <1/10W> + C319 47/ 35V 5V-2 3 G C327 0.1 I C322 NJM7805 C320 0.1 12V-2 D326 1SS355 15 14 13 12 11 10 9 V 5V-2 I C355 R355, R356 uLN2003ADR 1.0k <1/10W> 16 1C 1B 1 x2 12V-2 R395 1.0k <1/10W> A 3 C412 + C416 D412 R412 47/ D416 0.22 35V 18V 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 I U D355 SLR-325VC C395 0.1 1 CN395 B04B-PAKK-1 12V-2 A PTZ24B x3 C411 + C415 D411 R411 47/ D415 0.22 35V R475 10k <1/10W> IPM I C400 PS21A79 CN380 B3P5-VH-B-C 2 F380 5A - DC400V I P 330k D1FK60 <1/10W> x3 x3 N-I N 1 R460 - R464 0.018 <2W> 1% x5 R410 39 <1/4W> 15V-2 L400 BLM21AG601 D CN390 B02B-XASK-1-A 1 380V P K380 AJTV351-(TP) C390 18V 0.1 C391 + 47/ 35V 15V-2 P W393 N F4100D + + + INVERTER PCB ASSEMBLY K09CQ-1000HUE-TR1 380V 1 R453 1.0k <1/10W> C454 1000p D 2 I C450-1 BA2903F - + D 2 3 C452 330p D C453 470p 1 3 D453 DAN217U D R435 2.2k <1/10W> 1% R436 6.8k <1/10W> 1% R437 2.2k <1/10W> 1% R450 2.7k <1/10W> 1% R451 3.3k <1/10W> D 1% D 220k <1/3W> 1% x 16 OUTDOOR UNIT AOYG45LAT8 FILTER PCB ASSEMBLY K09CR-1000HUE-FL0 I C501 L18P050S05RK 5 +I N 6 -I N 1 GND +VCC 3 OUT 4 GND 2 PROTECTOR P501 45A - 500V TM505 0042902B L-IN 5V CN501 2-1871843-3 1 2 3 R502 33k <1/4W> C515 0.1 CS TM506 0042902B L501 FM-B304V212MBPF TM501 L503 N300300K1D7C-01N L502 FM-B304V212MBPF TM507 F4100D F4100D VA501 470V C507 0.033 1 1 2 C511 3.3 3 3 4 VA502 470V FH501 H0060 x 2 FH505 SA501 RA-302M FH506 F503 10A - 250V FH503 H0060 x 2 F502 3.15A - 250V W504 B FH504 TP00351-31 x 2 W505 B WHITE E W503 B GREEN L - OUT 2 AC POWER OUT for CONTROLLER PCB ASSY N - OUT 2 W506 B BLACK W507 B WHITE 2010.09.16 AC POWER OUT for INVERTER PCB ASSY 4 WHITE F501 10A - 250V N - OUT 1 C513 2.2 F4100D FH501 BLACK C512 3.3 TM508 TM502 WHITE AC POWER OUT for BRANCH BOX R501 1.0M C508 0.033 F4100D L - OUT 1 2 C506 3.3 C501 3.3 VA503 470V POWER SOURCE AC230V 50Hz N-IN L - OUT BLACK BLACK 34 N - OUT OUTDOOR UNIT AOYG45LAT8 INDICATOR, I / O PCB ASSEMBLY K09BI-1000HUE-C1 12V 12V CN931 B02B-XAYK-1-A D935 - D938 DAN217U x 4 Q934 2SA1036 3 1 EX I N 1 1 2 YELLOW 2 CN932 B02B-XAMK-1-A GREEN EX I N 2 3 1 CN933 B02B-XASK-1-A EX I N 3 3 1 1 2 3 1 3 2 SW941 CFS-0402MC Q935 - Q938 DTC124EUA x4 1 12V 2 4 5 6 3 P_MA I N_TXD P_MA I N_RXD 7 LED982 SLR-325VC R968 4.7k <1/10W> P_SW_I N6 D934 DAN202U Q933 DTC124EUA 3 2 1 2 D931 DAN202U 3 2 C922 0.1 C923 1000p 3 3 D932 DAN202U 3 Q932 DTC124EUA VCC CS DI DO NC SK TEST GND 1 1 1 3 Q964 2SA1036 P_SW_SELECT2 P_7SEG_SDP P_7SEG_C4 P_7SEG_SG P_7SEG_C3 P_7SEG_SF P_7SEG_C2 P_SW_I N0 P_7SEG_C1 P_7SEG_SA P_7SEG_SB P_7SEG_SC P_7SEG_SD 5V 12 R916 10k <1/10W> 13 P_7SEG_SD P_7SEG_SC P_7SEG_SB 3 NC 4 GND VDD 2 OUT 1 I C911 BU4842F C913 0.1 P_MA I N_TXD RESET 5V 1 2 P75 P33 3 P63 P62 2 1 P61 P60 VDD 22 23 24 P16 X1 X2 IC901 uPD78F0514 P14 P13 MD0 P123 P12 P124 P11 *RST P10 P40 AVDD AVSS P27 P26 26 P41 P25 27 P24 28 P23 29 P22 30 P21 31 P20 P130 P01 32 33 34 P120 P00 P140 P_7SEG_SF 48 P_7SEG_SG C902, C903 1.0 x 2 47 46 45 1 44 3 43 2 P_7SEG_SDP I C951-5 uLN2003 5 12 I C951-6 uLN2003 6 11 I C951-7 uLN2003 7 10 I C952-1 uLN2003 1 16 I C952-2 uLN2003 2 15 I C952-3 uLN2003 3 14 I C952-4 uLN2003 4 13 I C952-5 uLN2003 5 12 FLMD0 41 39 38 37 10 9 8 7 6 10 9 8 7 6 LED961 LTD-2601WC LED962 LTD-2601WC 1 2 3 4 5 1 2 3 4 5 12V 42 40 R969 - R976 330 <1/10W> x 8 X901 4.00MHz RESET P_EX_OUT1 P_EX_OUT1 I C952-7 uLN2003 7 10 K951 G5NB-1A 1 3 4 2 1 3 CN951 B02B-XAKK-1-A BLACK 1 3 4 P_STATUS 35 36 P_SW_I N5 5 P_PCS_RXD R901 10k <1/10W> P_SW_SELECT2 P_SW_I N4 FLMD0 P_PCS_TXD EX OUT 1 2 P_EX_OUT2 P_SW_I N6 R902 10k <1/10W> 6 P_EEP_I O P_SW_SELECT1 P_SSP_SK P_SW_SELECT0 P_EEP_CS R903 10k <1/10W> 2010.09.16 3 3 CN952 B02B-XAEK-1-A P_SW_I N7 WHITE FLASH P74 4 P15 25 CN901 B06B-PASK-1 P73 5 6 C 21 C905 0.1 P71 P72 7 VSS 20 5V 8 P17 19 P_MA I N_RXD P70 P32 P31 9 P30 18 P_LED_1 10 15 17 P_PCS_TXD 11 P_7SEG_SE C904 22 14 16 P_7SEG_SA P_PCS_RXD C911 0.1 Q963 2SA1036 Q962 2SA1036 Q961 2SA1036 1 P_LED_0 R911 47k <1/10W> R912 10k <1/10W> 2 P_7SEG_C4 P_SW_SELECT1 1 P_EEP_CS P_EEP_I O P_SSP_SK R917 10k <1/10W> 5V 2 P_7SEG_C2 P_SW_SELECT0 P_7SEG_SE 1 3 2 5 2 3 Q931 DTC124EUA 2 P_SW_I N3 I C916 M93C66 8 4 7 6 1 P_7SEG_C3 C931 - C934 0.01 x4 1 2 5V 2 P_7SEG_C1 P_SW_I N1 C916 0.1 R965 4.7k <1/10W> R966 4.7k <1/10W> 1 1 2 R967 4.7k <1/10W> R961 - R964 4.7k <1/10W> x 4 P_SW_I N7 P_SW_I N2 5V 14 5V P_STATUS R925 330 <1/10W> C921 0.1 1 3 R926 1.0k <1/10W> 3 P_SW_I N5 1 2 3 4 2 R922, R921, R923 47k <1/10W> 5V x3 L922 BLm18AG601 3 INDICATOR, I / O PCB COM. I C951-3 uLN2003 P_SW_I N4 SW931 - SW934 KSHC611BT x 4 D933 DAN202U L921 BLm18AG601 13 LED981 SLR-325MC R981, R982 330 <1/10W> x 2 P_SW_I N3 8 7 6 5 1 WHITE 4 8 P_SW_I N2 3 1 2 CN921 B07B-PASK-1 G/V P_SW_I N1 3 1 2 1 I C951-4 uLN2003 I C952-8 uLN2003 VCC P_SW_I N0 3 2 2 P_LED_1 R939 - R942 1.0k <1/10W> x4 1 2 CN934 B02B-XARK-1-A EX I N 4 R943 10k <1/10W> 3 9 I C951-8 uLN2003 8 R931 - R938 10k <1/10W> x 8 5V 2 R945 - R948 4.7k <1/10W> x 4 2 RED 1 G/V P_LED_0 2 WHITE VCC R944 10k <1/10W> 1 2 12V 9 35 P_EX_OUT2 I C952-6 uLN2003 6 11 K952 G5NB-1A BLUE 1 4 2 2 EX OUT 2 BRANCH BOX PCB CIRCUIT DIAGRAM UTP-PY03A CONTROL UNIT EZ-0101HME POWER SOURCE AC230V 50Hz L1 L2 UL1015 AWG20 BLACK UL1015 AWG20 W101 L-I N WHITE W102 N-I N F101 AC250V 10A 1 F102 AC250V 3.15A CN305 B06B-XARK-1-A RED 3 BRANCH PIPE - 2 2 1 UL1015 AWG20 BLACK UL1015 AWG20 WHITE UL1015 AWG20 BROWN UL1015 AWG20 BLUE 1 6 1 CN102 B4P7-VH-B CN306 B06B-XASK-1-A WHITE WHITE 6 1 7 3 BRANCH PIPE - 3 CONTROLLER PCB ASSEMBLY K10CQ-1000HME-C1 UL1015 AWG20 2 WHITE 1 UL1015 AWG20 WHITE W104 N-OUT UL1015 AWG20 BLACK W103 L-OUT CN307 B06B-XAMK-1-A GREEN CN308 B06B-XAEK-1-A 2 BLUE 1 UL1015 AWG20 WHITE UL1015 AWG20 BLACK 3 POWER SOURCE FOR INDOOR UNIT - 2 2 1 3 POWER SOURCE FOR INDOOR UNIT - 3 UL1015 AWG20 RED UL1015 AWG20 YELLOW UL1015 AWG20 PINK 1 2 1 3 UL1015 AWG20 WHITE UL1015 AWG20 AWG26 RED AWG26 AWG26 AWG26 AWG26 BLUE ORANGE YELLOW WHITE 1 BLACK BLACK CN309 B08B-PASK-1 ELECTRIC EXPANSION VALVE 1 EEV 2 ELECTRIC EXPANSION VALVE 2 EEV 3 ELECTRIC EXPANSION VALVE 3 EEV 4 ELECTRIC EXPANSION VALVE 4 TH1 WHITE THERMISTOR ( GAS TEMP. ) - 1 TH2 WHITE THERMISTOR ( LIQUID TEMP. ) - 1 BLACK BLACK WHITE UL1015 AWG20 VIOLET UL1015 AWG20 WHITE UL1015 AWG20 BLACK 5 UL1430 AWG22 UL1430 AWG22 UL1430 AWG22 RED WHITE BLACK BLACK TH3 RED THERMISTOR ( GAS TEMP. ) - 2 BLACK BLACK TH4 RED THERMISTOR ( LIQUID TEMP. ) - 2 1 BLACK BLACK TH1 GREEN THERMISTOR ( GAS TEMP. ) - 3 4 BLACK BLACK TH2 GREEN THERMISTOR ( LIQUID TEMP. ) - 3 8 CN105 B3P5-VH-B-C BLACK PRIMARY 2 F103 AC250V 3.15A CN310 B04B-PASK-1 1 WHITE CN304 B03B-XAKK-1-A BLACK 3 EMI FILTER ZCAT1518-0730 2 TURNS W201 E UL1015 AWG16 GREEN CN301 B06B-PASK-1 CN303 B5B-PH-K-S WHITE 1 CN311 B03B-PASK-1 WHITE 5 1 6 FLASH TEST WIRED REMOTE CONTROL UNIT ( OPTION ) 2010.09.14 RED BLUE ORANGE YELLOW WHITE BLACK BLACK SECONDARY 2 AWG26 AWG26 AWG26 AWG26 AWG26 PRIMARY 1 WHITE 1 1 RED BLUE ORANGE YELLOW WHITE 5 2 3 AWG26 AWG26 AWG26 AWG26 AWG26 EEV 1 6 CN104 B3P5-VH-B 1 OUTDOOR UNIT RED BLUE ORANGE YELLOW WHITE 6 1 3 POWER SOURCE FOR INDOOR UNIT - 1 AWG26 AWG26 AWG26 AWG26 AWG26 36 1 WHITE 3 BRANCH BOX UTP-PY02A CONTROL UNIT EZ-0102HME POWER SOURCE AC230V 50Hz L1 L2 UL1015 AWG20 BLACK W101 L - I N UL1015 AWG20 WHITE W102 N - I N F101 10A AC250V F102 3.15A 250V 1 CN305 B06B-XARK-1-A RED 3 BRANCH PIPE - 2 2 1 UL1015 AWG20 BLACK UL1015 AWG20 WHITE UL1015 AWG20 BROWN UL1015 AWG20 CN102 B4P7-VH-B 2 CN306 B06B-XASK-1-A WHITE WHITE BLUE WHITE UL1015 AWG20 WHITE W104 N - OUT UL1015 AWG20 BLACK W103 L - OUT WHITE 3 POWER SUPPLY FOR I NDOOR UNIT - 2 2 1 UL1015 AWG20 RED UL1015 AWG20 YELLOW 1 1 BLUE I NNER SERIAL 3 1 3 BLACK 1 UL1015 AWG20 VIOLET UL1015 AWG20 WHITE UL1015 AWG20 BLACK 5 UL1430 AWG22 UL1430 AWG22 UL1430 AWG22 EMI FILTER ZCAT1518-0730 2T RED WHITE BLACK ELECTRIC EXPANSION VALVE 2 EEV 4 ELECTRIC EXPANSION VALVE 4 TH1 WHITE THERMISTOR ( GAS TEMP. ) - 1 BLACK TH2 WHITE THERMISTOR ( LIQUID TEMP. ) - 1 BLACK BLACK BLACK TH3 RED THERMISTOR ( GAS TEMP. ) - 2 BLACK BLACK TH4 RED THERMISTOR ( LIQUID TEMP. ) - 2 8 CN105 B3P5-VH-B-C BLACK F103 3.15A AC250V PRIMARY 2 CN310 B04B-PASK-1 1 WHITE CN304 B03P5-XAKK-1-A SECONDARY 4 BLACK 3 CN301 B06B-PASK-1 W201 E UL1015 AWG16 GREEN CN303 B5B-PH-K-S WHITE CN311 B03B-PASK-1 WHITE 1 WHITE 1 5 1 6 FLASH TEST WIRED REMOTE CONTROL UNIT ( OPTION ) 2010.09.14 BLUE ORANGE YELLOW WHITE EEV 2 PRIMARY 1 1 2 RED AWG26 AWG26 AWG26 AWG26 BLACK BLACK 5 1 1 AWG26 WHITE UL1015 AWG20 WHITE 2 BLUE ORANGE YELLOW WHITE 6 CN104 B3P5-VH-B CN309 B08B-PASK-1 OUTDOOR UNIT RED AWG26 AWG26 AWG26 AWG26 ELECTRIC EXPANSION VALVE 1 6 2 UL1015 AWG20 AWG26 EEV 1 GREEN CN308 B06B-XAEK-1-A 1 BLUE ORANGE YELLOW WHITE CN307 B06B-XAMK-1-A 3 POWER SUPPLY FOR I NDOOR UNIT - 1 RED AWG26 AWG26 AWG26 AWG26 6 1 CONTROLLER PCB ASSEMBLY K10CQ-1000HME-C1 UL1015 AWG20 1 6 1 BP SERIAL 7 3 BRANCH PIPE - 3 1 AWG26 37 3 E W201 B UL1015 AWG16 SA101 RA-302M GREEN L-I N F102 3.15A 250V W101 B FH103 FH104 TP00351-31 x2 W102 L-OUT B N-OUT VA101 470V 1 2 D101 D3SB60 3 C107 33/ 450V 2 C106 0.22 4 FH102 PFC5000 -0702F x 2 I C101 TOP254 8 7 6 5 PIN101, PIN107 IPS-1124 8 14 7 10 6 5V 5 4 3 2 1 R231 47k <1/10W> 2 R232 27k <1/10W> R234 1.0k <1/10W> R233 4.7k <1/10W> C231 0.1 Q231 2SC2412K 2 3 3 1 CN104 B3P5-VH-B 5 12 HYIC102 HU2001R3 18 D 4 C M 2 1 + P_POWER 1 A 2 C111 R114 47/ 6.8 35V <1/4W> + C205, C206 R203 330p 180 x2 <1/10W> T101 EE28-B 1 2 3 4 D202 RF301B2S 12 11 10 9 6 7 8 PC101 PS2561L-1-V 4 1 3 2 14 7 10 6 C 3 C209 + 10/ 50V P_SO_I N 1 + A 2 C215 0.1 + L207, L208 BLM31PG121 x2 5V C218 1.0 F201 1.1A 16V D R213 100k <1/10W> 1% R208 3.0k <1/10W> 1% R207 8.2k <1/10W> D D203 RD8.2FM R212 330 <1/4W> 12V C217 1.0 R209 33 <1/4W> C213 1000/ 25V R205 C208 100 1.0 <1/10W> C210 1.0 R206 2.7k <1/10W> 1% P_S I_I N 1 C207 1000/ 25V R204 470 <1/4W> D C110 D104 10/ RF101L2S 50V R113 120 <1/4W> L204 2.2uH 16 15 L205, L206 BLM31PG121 x2 + C204 330/ 25V + C203 330/ 25V D201 RF601T2D R115 C121, C122 180 330p <1/10W> x2 R112 10k <1/10W> L202 2.2uH 3 I C230-5 uLN2003 PIN102 IPS-1124 8 C232 0.01 C108 2200p D102 ST03D-82 C112 0.1 R235 1.0k <1/10W> 5 4 3 2 1 S S S S C201, C202 R201 330p 180 x2 <1/10W> 1 R110, R111 22 <1/4W> x2 JM10 0R0 F101 10A 250V 1 WHITE + L101 18mH 18 R108, R109 470 <1/4W> x2 3 HYIC101 HU2001R3 W104 B I NNER SERIAL R102 4.7 C101 0.22 W102 B FH101 I NNER AC-OUT 1 C104 4700p 4 AC I N N-I N C104 4700p VA102 470V C214 4700p L209, L210 BLM31PG121 x2 REF 1 R211 2.7k <1/10W> 1% I C202 TL431A I 5V 5 4 3 2 1 5 4 3 2 1 R241 47k <1/10W> R242 27k <1/10W> R244 1.0k <1/10W> R243 4.7k <1/10W> Q241 2SC2412K 2 C241 0.1 3 1 P_S I_I N 2 I C230-4 uLN2003 PIN103 IPS-1124 HYIC103 HU2001R3 18 8 4 13 14 7 10 6 5V 5V 5 4 3 2 1 5 4 3 2 1 R251 47k <1/10W> R252 27k <1/10W> R254 1.0k <1/10W> R253 4.7k <1/10W> C251 0.1 Q251 2SC2412K 2 3 1 HYIC104 HU2001R3 2 BP SERIAL 18 8 P_S I_I N 3 PIN106 IPS-1124 R283 1.0k <1/10W> 3 14 WHITE 1 R282 10k <1/10W> I C230-3 uLN2003 PIN104 IPS-1124 CN102 B4P7-VH-B P_SO_I N 2 14 7 10 6 5 4 3 2 1 R261 47k <1/10W> 3 4 R284 1.0k <1/10W> 5V 5 4 3 2 1 R262 27k <1/10W> R264 1.0k <1/10W> R263 4.7k <1/10W> P_POWER 2 C261 0.1 Q261 2SC2412K 2 3 1 P_S I_BP 1 HYIC105 HU2001R3 P_SO_OUT 2 15 C282 0.01 C283 0.01 3 I C230-2 uLN2003 PIN105 IPS-1124 L281 BLm18AG601 P_S I_OUT P_SO_I N 3 P_SO_BP 1 HYIC106 HI2003R3 3 1 1 2 3 4 5 1 2 3 4 5 C285 C284 470p 470p Q281 DTC124EUA 2 C281 0.01 D 10 6 C120 1000p 5V 2 1 3 7 18 8 CN105 B3P5-VH-B-C BLACK VA103 470V 3 2 FH106 D281 DAN217U 2 Q282 DTC124EUA 14 TP00351-31 x2 FH105 1 F103 3.15A 250V 1 5V R271 47k <1/10W> R272 27k <1/10W> R273 4.7k <1/10W> R274 1.0k <1/10W> C271 0.1 Q271 2SC2412K 2 3 1 5V P_S I_BP 2 9 I C230-8 uLN2003 VCC G/V 8 I C230-1 uLN2003 16 2010.09.14 1 BRANCH BOX UTP-PY03A UTP-PY02A P_SO_BP 2 38 CONTROLLER PCB ASSEMBLY - 1 K-10CQ-1000HME-C1 OUTER OR BP SERIAL CN301 B06B-PASK-1-A 5V WHITE R308 1.0k <1/10W> 1 2 3 FLASH I C331 uPD78F1164 RESET MODE0 5 6 P_RC_TXD LED_0 LED_1 LED_2 LED_3 LED_4 TOOL0 C306 0.1 R309 10k <1/10W> X331 8.00MHz TOOL1 3 P_RC_RXD 2 1 R336, R337 10k <1/10W> x2 R305 47k <1/10W> 5V I C301 S80842 P_TEST_DO P_TEST_D I R306 10k <1/10W> VDD 2 3 NC 4 GND OUT 1 C302 1.0 TPE4 TPE3 TPM3 TPE2 TPM2 TPE1 TPM1 P_TEST_CL P_POWER2 R313 - R315 10k <1/10W> x3 5V CN303 B5B-PH-K-S R316 330 <1/10W> WHITE 1 3 2 100 99 98 64 82 81 80 79 78 77 76 75 63 P142 VDD P00 EVDD0 P01 EVDD1 P02 P40 P03 P41 P04 P42 P05 P43 P06 P44 P45 P10 P11 P46 P110 P47 P111 P50 P51 P12 P120 P52 P121 P53 P122 P54 P123 P55 P124 P56 P13 P57 P130 P60 P61 P131 P14 P62 P140 P63 P141 P64 P65 P143 P144 P66 P145 P67 P15 P70 P71 P150 P72 P151 P152 P73 P74 P153 P154 P75 P155 P76 P156 P77 P157 P80 P81 P16 62 90 89 88 87 86 85 84 83 52 28 74 43 P17 P82 P20 P83 P21 P84 P22 P85 P86 P23 P24 P87 P25 AVREF1 P26 AVREF0 P27 RESET* P30 FLMD0 P31 REGC AVSS EVSS0 EVSS1 VSS P_TEST_CL R317 C304 330 1000p <1/10W> 5 5 54 55 56 57 58 59 60 61 24 25 26 27 29 30 31 32 40 39 38 37 36 35 34 33 44 45 46 47 48 49 50 51 70 73 13 16 19 21 20 C333, C337 0.1 2 P_TEST_D I C305 1000p LED_0 2 I C400-3 uLN2003 LED_1 3 14 CN304 B03B-XAKK-1-A BLACK 1 REMOTE 2 3 L341 BLm18AG601 C341 0.1 R345 - R347 120 <1/4W> x3 D342 DAN217U R342 15.4k <1/10W> 1% R343 28k <1/10W> 1% 1 R341 1.0k <1/10W> 2 3 C342 1000p LED_3 10 5V 2 3 + C343 0.1 4 13 I C400-5 uLN2003 12V R344 10k <1/10W> D341 D1FS4A L342 BLm18AG601 LED_2 F341 0.2A 30V 7 LED_4 R348 10k <1/10W> I C341-1 BA10393F R349 1.0k <1/10W> C344 1000p 12 I C400-6 uLN2003 P_RC_TXD I C310-7 uLN2003 1 5 6 11 G/V 4 6 5 - + 2 TPE3 C512 0.1 R511 49.9k <1/10W> 1% C510 0.1 R509 49.9k <1/10W> 1% R514 10k <1/10W> TPE4 R331 10k <1/10W> P_EEPROM_DO P_EEPROM_CS P_EEPROM_D I P_EEPROM_SK R335 10k <1/10W> 1 2 R513 49.9k <1/10W> 1% 1 3 2 5 CS VCC DI DO SK NC GND TEST 8 4 7 6 C334 0.1 CN305 B06B-XARK-1-A 12V RED 1 2 P_EPV_A3 P_EPV_A2 P_EPV_A1 I C310-6 uLN2003 I C311-6 uLN2003 6 I C310-5 uLN2003 I C311-5 uLN2003 6 11 5 3 EXPANSION VALVE 4 11 5 12 5 6 12 CN306 B06B-XASK-1-A R402 LED402 330 SLR-325 RED <1/10W> WHITE 1 2 LED403 R403 SLR-325 330 RED <1/10W> P_EPV_B3 P_EPV_B2 P_EPV_B1 I C310-4 uLN2003 I C311-4 uLN2003 4 3 13 3 EXPANSION VALVE 4 13 I C310-3 uLN2003 I C311-3 uLN2003 4 3 14 5 6 14 CN307 B06B-XAMK-1-A LED404 R404 SLR-325 330 RED <1/10W> GREEN 1 2 P_EPV_C4 R405 LED405 330 SLR-325 RED <1/10W> P_EPV_C3 P_EPV_C2 P_EPV_C1 I C310-2 uLN2003 I C311-2 uLN2003 2 1 15 1 16 3 EXPANSION VALVE 4 15 I C310-1 uLN2003 I C311-1 uLN2003 2 5 6 16 CN308 B06B-XAEK-1-A BLUE 1 2 P_EPV_D4 P_EPV_D3 P_EPV_D2 P_EPV_D1 I C313-2 uLN2003 I C312-2 uLN2003 2 I C313-1 uLN2003 I C312-1 uLN2003 1 2 3 4 1 16 SW-3 C402 - C405 0.01 x4 39 15 15 BRANCH BOX UTP-PY03A UTP-PY02A 2011.01.20 + C500 10/ 50V I C332 S-93C66B0 I SW-2 8 7 6 5 THERMISTOR 3 C514 0.1 5V R401 LED401 5V 330 SLR-325 GREEN <1/10W> 7 SW401 CFS-0402MC CN311 B03B-PASK-1 WHITE R410 - R413 1.0k <1/10W> x4 1 2 3 4 THERMISTOR 3 4 SW-1 I C341-2 BA10393F WHITE 1 R406 - R409 5V 10k <1/10W> x4 P_RC_RXD CN310 B04B-PASK-1 R507, R505, R503, R501 49.9k <1/10W> x 4 TPM3 SW-0 8 VCC 7 8 C335 0.1 12V I C341-3 BA10393F C345 0.1 6 R510, R512 10k <1/10W> x2 P_EPV_B4 I C400-4 uLN2003 THERMISTOR 5 TPM2 TPE2 RESET MODE0 15 3 4 C508, C506, C504, C502 0.1 x 4 P_EPV_C4 P_EPV_C3 P_EPV_C2 P_EPV_C1 P_EPV_D4 P_EPV_D3 P_EPV_D2 P_EPV_D1 SW-0 SW-1 SW-2 SW-3 P_EEPROM_DO P_EEPROM_D I P_EEPROM_SK P_EEPROM_CS P_SO_I N1 P_SO_I N2 P_SO_I N3 P_SO_BP1 P_SO_BP2 P_SO_OUT P_S I_OUT P_S I_BP2 P_EPV_A4 P_EPV_A3 P_EPV_A2 P_EPV_A1 P_EPV_B4 P_EPV_B3 5V-2 P_EPV_B2 P_EPV_B1 C336 0.1 2 TPE1 + C331 1000/ 25V x TOOL0 TOOL1 P_S I_BP1 P_S I_I N3 P_S I_I N2 P_S I_I N1 P_POWER I C400-2 uLN2003 P_TEST_DO 3 4 22 23 53 12 11 10 9 8 7 6 1 TPM1 P_EPV_A4 2 TEST ( PCS ) 1 97 96 95 94 93 42 41 69 68 71 72 67 4 18 17 15 14 66 91 92 65 WHITE L501 BLm18AG601 R502, R504, R506, R508 10k <1/10W> x 4 L331 2.2uH 5V-2 4 C301 0.1 CN309 B08B-PASK-1 5V R311, R312 10k <1/10W> x2 CONTROLLER PCB ASSEMBLY - 2 K-10CQ-1000HME-C1 16 5 6 EXPANSION VALVE TERMINAL HP-T3064A-A29-L1 INDOOR PCB CIRCUIT DIAGRAM BRANCH BOX UNIT POWER SOURCE AC230V 50Hz UL1015 AWG24 BLACK 2 UL1015 AWG24 WHITE 3 UL1015 AWG24 L 1 N SERIAL CONTROLLER PCB ASSEMBLY ( MAIN PCB ) ASYG07LJCA : K09DS-1006HSE-C1 ASYG09LJCA : K09DS-1007HSE-C1 ASYG12LJCA : K09DS-1008HSE-C1 F1 AC250V 3.15A 1 2 3 4 RED CN1 2013485-1 WHITE 5 E CONTROL UNIT ASYG07LJCA : EZ-010MHSE ASYG09LJCA : EZ-010PHSE ASYG12LJCA : EZ-010RHSE 1 2 CN9 B07B-PASK-1 WHITE 3 4 5 FLASH 6 7 UL1015 AWG22 GREEN W4 E EARTH CN4 B04B-PL I SK-1 EARTH FM DC FAN MOTOR WHITE BLUE 1 YELLOW 2 WHITE 3 BLACK 4 5 RED CN5 B05B-PL I SK-1 WHITE 1 BLACK 2 BLACK 3 BLACK 4 BLACK 1 RED 2 ORANGE 3 YELLOW 4 PINK 5 CN7 B5 ( 6-5 ) B-XARK-1-A THERMISTOR ( PIPE TEMPERATURE. ) THERMISTOR ( ROOM TEMPERATURE ) M LOUVER BLUE UL1061 AWG28 x 5 RED 6 UL3226 AWG22 x 5 CN3 B07B-PL I SK-1 WHITE OPTION 1 RED 1 2 WHITE 2 3 WHITE 3 4 WHITE 4 5 WHITE 5 6 WHITE 6 WHITE 7 7 CN201 JB20-07 WHITE UL1061 AWG28 x 7 CN6-1 RED 1 CN6-2 WHITE 2 CN6-3 BLACK 3 4 CN305 B05B-XASK-1-A WHITE 5 CN301 SJH20-08WSF UL1061 AWG26 x 3 WIRED REMOTE CONTROL UNIT ( OPTION ) EXTERNAL WHITE 1 I NPUT 2 3 CN303 B3B-XH-AM WHITE COMMUNICATION PCB ASSEMBLY K08DG-0801HSE-CA0 1 WHITE 1 2 WHITE 2 3 WHITE 3 4 WHITE 4 5 WHITE 5 6 6 7 7 8 WHITE UL1007 AWG24 x 6 EXTERNAL OUTPUT 2010.09.08 1 2 CN304 B2B-XH-AM WHITE 40 8 CN8 SJH20-08WSFB WHITE INDICATOR PCB ASSEMBLY K07BJ-0900HSD-D0 1 CN6 B5B-PH-K-S WHITE 2 3 4 5 TEST INDOOR UNIT COMPACT WALL MOUNTED CONTROLLER PCB ASSEMBLY ( MAIN PCB ) ASYG07LJCA : K09DS-1006HSE-C1 ASYG09LJCA : K09DS-1007HSE-C1 ASYG12LJCA : K09DS-1008HSE-C1 W4 GREEN B E 340V F1 250V 3.15A FH2 TP0035-31 x 2 FH1 CN1 2013485-1 WHITE 1 1 3 AC I N 5 L5 20*20*18 0.6A - 10mH C3, C2 L1 0.01 18mH x2 D5 S1NBC60 2 C1 0.1 VA1 470V 4 R3 56k <1/4W> 2 + 1 3 - 4 C4 + 68/ 420V 3 C5 0.01 R53, R54 22k <1/4W> x2 T1 MY082N R2 100 <1/4W> 2 9 3 8 D2 UF4007 4 7 5 6 IC2 HI2003R3 S S S S BP_M 2 EN_UV 1 14 8 10 7 5 6 5 4 4 3 C29 1000p 3 2 2 1 1 A JM2 0R0 R12, R48 470 <1/4W> x2 3 R8 1.0k <1/10W> C 1 I C6 TL431 I Z R13 10k <1/10W> 2 Q1 RT1N241M I C13-6 uLN2003ADR 11 5V 6 I C1-32 1 I C1-79 2 A I C1-42 WHITE 1 3 2 5 A CS VCC DI DO SK NC GND TEST R56, R58, R59 100 <1/10W> x 3 1 2 I C1-8 4 I C1-9 5 I C1-13 6 7 A L4 0R0 4 THERMISTOR 3 2 C80 1000p I C1-54 I C1-53 I C1-52 I C1-51 R47 10k <1/10W> A L6 0R0 R39 10k <1/10W> 1% L3 0R0 1 A R41 49.9k <1/10W> 1% 2010.09.08 C36 0.1 10 BZ I C1-80 I C1-36 I C13-7 uLN2003ADR R43 10k <1/10W> A 7 C41 0.1 I C1-1 5V R46 1.0k <1/10W> A A I C1-62 I C1-61 I C1-40 R38 1.0k <1/10W> R40 1.0k <1/10W> C28 0.1 I C1-61 I C1-5 I C1-4 A C31 0.1 A I C1-9 I C1-8 I C1-62 I C1-41 I C1-10 I C1-13 C17 1.0 VCC EVCC AVREF0 AVREF1 P51 P52 P53 P54 P55 P60 P61 P62 P63 P64 P65 P66 P67 P70 P71 P72 P73 P74 P75 P76 P77 P90 P110 P111 P120 P121 P122 P123 P124 19 20 59 56 42 43 44 45 46 21 22 23 24 26 27 28 29 37 36 35 34 33 32 31 30 55 57 58 1 15 14 12 11 P130 P140 P141 P142 P143 P144 P145 69 80 79 78 77 76 75 74 73 72 71 70 39 38 54 53 52 51 50 49 48 47 68 67 66 65 64 63 62 61 40 P00 P01 P02 P03 25 9 8 P31 P40 P41 7 6 5 4 3 2 41 10 13 16 17 60 18 P42 P43 P44 P45 P46 P47 P50 *RESET FLMD0 REGC GND AGND EGND P04 P05 P06 P10 P11 P12 P13 P14 P15 P16 P17 P20 P21 P22 P23 P24 P25 P26 P27 P30 A 41 + C18 10/ 25V C24 1.0 Q2 RT1N241M C19 1.0 I C1-39 A I C1-40 A 2 3 3 2 5V R36 10k <1/10W> A C50 1000p C25 1000p A A 340V CN7 B5 ( 6-5 ) B-XARK-1-A 1 RED R25 10k <1/10W> 1% 5 4 3 R26 8.2k <1/10W> 1% A C6 + 10/ 25V A A I C1-36 I C1-35 R60, R61 10k <1/10W> x 2 A I C1-77 I C1-76 5V 340V 8 A 5 4 3 2 C14 1000p A C15 0.1 A I C1-33 I C1-5 CN8 SJH20-08WSF WHITE R30 R19 R22 R23 100k 10k 10k 1.0k <1/10W> <1/10W> <1/10W> <1/10W> I C1-41 X1 8.00MHz I C1-80 I C1-79 A I C1-4 I C1-55 2 A R20 1.0k <1/10W> I C1-35 I C1-1 1 5V R21 10k <1/10W> C23 1000p I C1-33 I C1-32 I C1-31 I C1-30 I C1-55 DC FAN MOTOR 2 I C1-21 I C1-22 I C1-23 A 7 R37 47 <1/10W> 1 I C1-42 3 6 15V-3 Q3 DTA124EUA 1 5V I NDICATOR PCB ASSY 5 15V-2 5V WHITE R45 10k <1/10W> BZ1 PS1240P02BT 15V 8 4 7 6 I C12 S-93C66BD0 I I C1-73 I C1-72 I C1-71 I C1-70 I C1-39 I C1-10 3 CN4 B04B-PL I SK-1 3 4 I C1-21 R55 10k <1/10W> IC1 uPD78F1154AGK R89 10k <1/10W> 2 I C1-22 5V 5V WHITE 1 I C1-23 5V A R86 - R88 5V 10k <1/10W> x 3 CN3 B07B-PL I SK-1 R29, R28, R27 270 <1/10W> x 3 I C1-77 C44 1000p C42 1000p 5 FLASH 5 13 I C13-1 - I C13-4 uLN2003ADR x 4 5V C20 0.01 A LOUVER 3 4 4 I C1-51 WHITE 2 14 I C1-76 4 CN9 B07B-PASK-1 I C1-31 1 15 3 I C1-52 CN5 B05B-PL I SK-1 R31 - R34 47 <1/10W> x 4 16 I C13-5 uLN2003ADR R44 10k <1/10W> 3 TEST A R14 1.0k <1/10W> 5 15V A 2 I C1-53 I C13-8 uLN2003ADR 8 1 I C1-54 I C1-73 I C1-71 I C1-72 I C1-70 R49, R51 10k <1/10W> x2 WHITE 1 9 VCC A I C1-30 5V CN6 B5B-PH-K-S 3 15V R9 10k <1/10W> 1% G/V A 5V REF 3 A 2 R10 10k <1/10W> 1% A C21 0.01 12 C11 0.1 2 2 1 R57 0R0 R6 R7 150 1.0k <1/10W> <1/10W> Q6 2SA1576A 3 Q5 2SC4081 15V-3 15V-2 JM1 0R0 5V + D4 D1FL20U 1 C12 0.1 R15 1.0k <1/10W> L2 BLm18 C9 330/ 25V R11 27k <1/10W> D7 1SS355 D 4 5V 18 15V C10 + 220/ 25V A I C8 TNY274PN 5 6 7 8 15V D3 D1FL20U 10 C51 0.1 A R42 1.0k <1/10W> R72 1.0k <1/10W> 5V R71 10k <1/10W> 1 5V R52 100k <1/10W> ( COMMUNICATION PCB ASSY ) INDOOR UNIT COMPACT WALL MOUNTED ASYG07LJCA ASYG09LJCA ASYG12LJCA INDICATOR PCB ASSEMBLY K07BJ-0900HSD-D0 5V 5V CN201 7 - JB / PL I L=230 #26 / 1061 1 D201 SLR-343MC D202 SLR-343DC D203 SLR-343MC GREEN 2 ORANGE 3 GREEN 4 5 A I C201 GP1UM261 5V VCC 2 OUT 1 GND 3 A C202 + 47/ 10V R202 47 <1/4W> 42 7 A C203 0.1 A 2010.09.08 6 SW201 KSHC611BT TO CONTROLLER PCB ASSENBLY POWER CN301 SJH20-08WSF POWER 8 GND 5 HA / EX I N 4 HA / EX OUT 3 WIRED I N 2 WIRED OUT 1 13V 390V R301 390k <1/4W> R302 270 <1/4W> T301 SW161-1 C302 1000p 10 1 2 3 5 4 6 + D302 RF101L2S I C301 LNK603PG 5 S 6 S 7 S 8 S C306 100/ 25V JM303 0R0 R309 18k <1/10W> D301 UF4007 C301 4.7/ 450V + D303 RF101L2S UTY-XCBXZ1 The limitation optional of ASYG07, 09 and 12LJCA 12V 12V D 4 BP_M 2 FB 1 R306 1.0k 1% R303 18k R304 36k <1/10W> 1% C305 R305 6.2k 1.0 1% C311 + 100/ 25V COMMUNICATION PCB ASSEMBLY K08DG-0801HSE-CA0 A A 13V E. X. L301 0R0 R312 1.2k <1/4W> C313 0.01 I C306 PS2501L-1 A 4 1 3 2 3 1 EXTERNAL I NPUT 2 3 L302 0R0 12V Q301 DTC123EUA CN303 B3B-XH-AM K301 G5NB-1A 1 3 4 2 WIRED REMOTE CONTROL UNIT CN304 B2B-XH-AM 1 EXTERNAL OUTPUT 2 2 1 Q304 DTC143EUA 13V 12V R331 22k <1/10W> A 3 I C308 PS2501L-1 2 4 3 1 13V 1 1 2 R315 2.7k <1/10W> A A 12V 13V R316 1.2k <1/4W> 3 I C309 PS2501L-1 1 4 2 3 5 + 6 - I C304-2 BA10393F 7 C310 1000p 3 2 1 C309 0.01 43 R318 15.4k <1/10W> 1% R319 28k <1/10W> 1% R322 10k <1/10W> A 2010.09.08 4 C304 0.1 13V R330 2.7k <1/10W> 1 I C304 3 + - 2 2 Q302 DTC143EUA 8 I C304-1 BA10393F R320 390 <1/4W> 1% Q303 DTC143EUA 13V 13V 13V R317 10k <1/10W> 1% D307 D1F60 3 D306 DAN217U 1 2 CN305 B05B-XASK-1-A 1 2 L303 0R0 3 4 5 TO WIRED REMOTE CONTROL INDOOR UNIT WALL MOUNTED CONTROL UNIT ASYG18LFCA : EZ-010YHSE ASYG24LFCA : EZ-01001HSE L IN TM4 22007 TERMINAL HP-T3064A-A29-L1 BRANCH BOX UNIT L POWER SOURCE AC230V 50Hz N SERIAL 1 UL1015 AWG24 BLACK 2 UL1015 AWG24 WHITE 3 UL1015 AWG24 RED F1 AC250V 3.15A BLACK 1 N IN TM1 22007 2 CN9 B07B-PASK-1 WHITE WHITE E UL1015 AWG22 WIRED REMOTE CONTROL UNIT ( OPTION ) EMI FILTER ESD-R19 4 TURNS GREEN SERIAL I N TM2 22007 3 4 FLASH 5 6 7 RED EARTH E W5 GREEN CN6-1 RED 1 CN6-2 WHITE 2 CN6-3 BLACK 3 4 CN6 B05B-XASK-1-A CONTROLLER PCB ASSEMBLY ( MAIN PCB ) ASYG18LFCA : K09DR-1001HSE-C1 ASYG24LFCA : K09DR-1002HSE-C1 INDICATOR PCB ASSEMBLY K05CY-0902HSE-D0 WHITE 5 UL1061 AWG26 x 3 CN2-1 M LOUVER ( RIGHT / LEFT ) RED 1 CN2-2 ORANGE 2 CN2-3 YELLOW 3 CN2-4 PINK 4 CN2-5 BLUE 5 CN2 SJH20-05WS WHITE CN11 B07B-PASK-1 WHITE UL1061 AWG26 x 5 1 CN11-1 RED 1 2 CN11-2 WHITE 2 3 CN11-3 WHITE 3 4 CN11-4 WHITE 4 5 CN11-5 WHITE 5 6 CN11-6 WHITE 6 CN11-7 WHITE 7 7 1 M LOUVER ( UP / DOWN ) CN5-1 RED 2 CN5-2 ORANGE 3 CN5-3 YELLOW 4 CN5-4 PINK 5 CN5-5 BLUE 6 CN5 SJH20-06WS WHITE CN14 B3B-XH-AM M LOUVER ( DIFFUSER ) WHITE RED 1 CN8-2 ORANGE 2 CN8-3 YELLOW 3 CN8-4 PINK 4 CN8-5 BLUE 5 WHITE UL1061 AWG28 x 7 UL1061 AWG26 x 5 CN8-1 CN201 07 JB20 / PAP 1061 CN16 B2B-XH-AM WHITE CN8 B06B-PASK-1 1 2 EXTERNAL I NPUT 3 1 EXTERNAL OUTPUT 2 WHITE XARR XAP -03VF -03V-1 6 UL1061 AWG26 x 5 CN3 JC25-02HG WHITE 1 CN3-1 2 CN3-2 RED BLACK WHITE BLACK THERMISTOR ( PIPE TEMPERATURE ) UL1007 AWG26 x 2 CN10-6 RED CN1 150-103-86172 6 5 DC FAN MOTOR FM CN10-4 BLACK 4 CN10-3 WHITE 3 CN10-2 YELLOW 2 CN10-1 BLUE 1 WHITE CN2-1 BLACK CN2-2 BLACK 1 CN13-1 CN10 B5 ( 6-5 ) B-XARK-1-A RED UL3266 AWG22 x 5 CN13 B5B-PH-K-S WHITE 2010.09.08 1 2 44 2 CN13-2 3 CN13-3 4 CN13-4 5 CN13-5 TEST THERMISTOR ( ROOM TEMPERATURE ) INDOOR UNIT WALL MOUNTED CONTROLLER PCB ASSEMBLY ( MAIN PCB ) ASYG18LFCA : K09DR-1001HSE-C1 ASYG24LFCA : K09DR-1002HSE-C1 F1 3.15A 250V TM4 I C26-10 I C26-14 VA1 470V L-IN FH1 D6 D3SB60 4 FH2 C13 0.01 C14 0.01 C8 0.47 TP00351-31 x2 TM1 N-IN 1 L2 0.6A - 10mH 1 3 2 R46, R120 22 <1/4W> x2 2 6 D 5 F 4 S C 1 L 2 X 3 R49 5.6k D4 <1/10W> D1FL20U R42 270 <1/10W> 3 2 Q7 2SA1037AK I C19 TL431 I LP 1 2 C27 + 47/ 35V + C33 47/ 35V R38 15k <1/10W> 3 C 3 R34 12k <1/10W> GND +C17 330/ 25V C12 0.1 R43 5V 330 1 <1/10W> I C1-39 15V 2 1 I C1-51 I C1-52 I C1-53 I C1-48 18 8 14 7 5 4 3 2 1 5 4 3 2 1 10 6 R106 470 <1/4W> C101 R122 4700p 470 <1/4W> 1 TM2 1 D14 DAN202K SERIAL VA6 470V 1 C2 0.1 2 L6, L7 BLm18 x2 1 THERMISTOR ( PIPE TEMP. ) C3 0.1 2 CN13 B5B-PH-K-S WHITE Q11 RT1N241M R14 1.0k <1/10W> 5V CN3 02 / 03 JC25 / XARR 1 5V R99, R98, R97 10k <1/10W> x3 C15 0.1 R6 49.9k <1/10W> 1% C16 0.1 5V 5 I C1-77 C47 1000p R90 - R92 330 <1/10W> x 3 5V R54 0R0 2 I C1-10 I C1-8 4 3 EXTERNAL I NPUT R101 330 <1/10W> I C1-4 I C1-41 I C1-10 I C1-13 5V L3 0R0 5V 2 1 C51 0.01 2010.09.07 I C1-13 R35 10k <1/10W> 7 WHITE I C1-9 I C1-8 I C1-9 5 6 CN14 B3B-XH-AM I C1-54 I C1-53 I C1-52 I C1-51 I C1-50 I C1-49 I C1-48 I C1-47 I C1-62 I C1-61 I C1-40 3 FLASH R32 5V 10k <1/10W> IC1 78F1154AGK R9 10k <1/10W> R41, R37, R40 100 <1/10W> x 3 1 L4 0R0 10 I C18-7 uLN2003ADR I C1-36 I C1-73 I C1-72 I C1-71 I C1-70 I C1-39 I C1-79 R86 - R88 10k <1/10W> x 3 WHITE 7 I C1-80 C26 0.1 R52 10k <1/10W> I C1-62 C49 1000p 3 5V 8 4 7 6 I C1-50 I C1-43 I C1-44 R109 10k <1/10W> SW1 KSMC632B I C25 PS2561L-1-V 1 4 2 3 R104 R89 10k 1.0k <1/10W> <1/10W> C57 0.01 C5 0.1 74 73 72 71 70 39 38 54 53 52 51 50 49 48 47 68 67 66 65 64 63 62 61 40 25 9 8 7 6 5 4 3 2 41 10 13 16 17 60 18 VCC P00 P01 EVCC P02 AVREF0 P03 AVREF1 P04 P51 P05 P52 P06 P53 P10 P54 P11 P55 P12 P60 P13 P61 P14 P62 P15 P63 P16 P64 P17 P65 P20 P66 P21 P67 P22 P70 P71 P23 P24 P72 P25 P73 P74 P26 P27 P75 P76 P30 P31 P77 P90 P40 P41 P110 P111 P42 P120 P43 P44 P121 P45 P122 P46 P123 P47 P124 P130 P50 *RESET P140 FLMD0 P140 REGC P142 GND P143 AGND P144 EGND P145 19 20 59 56 42 43 44 45 46 21 22 23 24 26 27 28 29 37 36 35 34 33 32 31 30 55 57 58 1 15 14 12 11 69 80 79 78 77 76 75 +C18 10/ 25V C7 0.1 C9 0.1 C20 0.1 2 1 I C7-6 uLN2003ADR 6 11 5 12 9 VCC 9 VCC G/V 8 G/V 8 G/V 8 I C1-45 I C1-46 I C7-4 uLN2003ADR 4 13 5 I C7-3 uLN2003ADR 3 14 6 I C16-3 uLN2003ADR 3 14 I C16-2 uLN2003ADR 2 15 3 4 1 2 3 I C16-1 uLN2003ADR 1 16 I C7-7 uLN2003ADR 7 10 5 I C16-7 uLN2003ADR 7 10 2 I C16-6 uLN2003ADR 6 11 I C16-5 uLN2003ADR 5 12 I C16-4 uLN2003ADR 4 13 4 3 4 MANUAL AUTO SWITCH R57, R60, R58 330 <1/10W> x 3 I C1-21 LOUVER ( DIFFUSER ) CN2 SJH20-05WS WHITE LOUVER ( RIGHT / LEFT ) CN5 SJH20-06WS WHITE LOUVER ( UP / DOWN ) 5 6 5V CN11 B07B-PASK-1 R110 10k <1/10W> 1 WHITE 2 3 4 I C1-23 INDICATOR PCB ASSY 5 6 I C1-1 I C16-8 uLN2003ADR R113 47 <1/10W> C58 1000p C53 1000p C40 + 100/ 25V 12V I C18-1 uLN2003ADR I C1-42 I C1-43 I C1-44 I C1-45 I C1-46 I C1-21 I C1-22 I C1-23 CN8 B06B-PASK-1 2 I C1-22 9 VCC DC FAN MOTOR R63 6.8k <1/4W> I C7-5 uLN2003ADR I C18-8 uLN2003ADR C21 0.1 3 1 BZ R33 1.0k <1/10W> C28 0.01 I C7-8 5V uLN2003ADR 5V I C1-76 4 VCC DO NC 5 GND TEST I C1-61 R2 10k <1/10W> 1% R13 1.0k <1/10W> 1 CN9 B06B-PASK-1 I C1-31 1 CS 3 DI 2 SK I C1-49 BZ1 PKM13EPYH-4000-A0 12V 12V 2 TEST I C1-42 I C1-73 I C1-71 I C1-72 I C1-70 I C26-10 I C26-14 CN1 150-103-86172 THERMISTOR ( ROOM TEMP. ) 2 2 C50 0.01 R103 390 <1/10W> 3 3 C54 0.01 R105 10k <1/10W> 3 2 I C6 S-93C66B0 I I C1-32 5V Q10 RT1N241M R39 10k <1/10W> 5V 4 A A WHITE A 5V 1 RED 5 R56 4.7k <1/10W> 3 2 R44 1.0k I C14 <1/10W> PS2561L-1-V CN10 B5 ( 6-5 ) B-XARK-1-A 1 I C1-47 R114 390 <1/10W> +C36 100/ 25V 15V 4 C30 1000p I C1-54 5V I C10 PS2561L-1-V 5V R47 10k <1/10W> 340V 15V 12V C42 C56 + 330/ 0.1 25V A IC26 HI2003R3 3 O 3 G R8 1.0k C25 0.1 C39 + 100/ 50V 1 I 2 Q6 DTC124EUA I C1-40 I C20 78M15 JM9 0R0 20V 3 R55 820 15V R51 1.0k <1/4W> <1/4W> 1% 4 2 D16 1SS355 R48 200k <1/10W> 1% R76 47k <1/10W> 1% D9 D1FL20U 5V 1 3 2 REF 1 A 2 I C2 BA05T JM3 0R0 C22 0.1 R67 R64 150 1.8k <1/10W> <1/10W> C38 R53 0.1 5.6k <1/10W> I C15 PS2561L-1-V 1 7V + C19 330/ 25V C35, C61 0.01 x2 4 + D10 1000/ D1FL20U 25V 8 9 10 D15 1SS355 12V C37 6 5 4 3 2 1 D8 1SS355 C32 0.01 C4 47p D7 UF4007 C29 I C8 0.22 TOP244YN 4 L1 SS28V <060330> W5 B E 3 R45 100k C6 + 100/ 420V D12 D2FL20U T1 MY064 VCC OUT 340V 1 I C1-4 7 C41 0.01 CN16 B2B-XH-AM K10 G5NB-1A 16 4 2 1 3 WHITE 1 2 EXTERNAL OUTPUT I C1-36 I C1-35 I C1-32 I C1-31 I C1-35 I C1-1 1 R30 5V 10k <1/10W> X1 8.00MHz 2 3 I C1-80 I C1-79 I C1-77 I C1-76 I C1-35 R4, R5 10k <1/10W> x2 I C1-41 I C1-55 C60 1000p 1 R36 1.0k <1/10W> I C5-2 BA10393F 7 12V 6 + 5 I C5-1 BA10393F 1 2 + 3 12V R21 15.4k <1/10W> 1% R22 28k <1/10W> 1% D3 12V DAN217U 1 R31 12V 390 <1/4W> 8 1% VCC I C5-3 BA10393F G / V R17 10k <1/10W> C23 0.1 CN6 B05B-XASK-1-A WHITE 1 2 16 I C7-1 uLN2003ADR F3 0.2A - 30V D2 D1F60 2 3 4 45 12V JM5 0R0 3 4 5 WIRED REMOTE CONTROL UNIT INDOOR UNIT WALL MOUNTED ASYG18LFCA ASYG24LFCA INDICATOR PCB ASSEMBLY K05CY-0902HSE-D0 5V 5V CN201 07 JB20 / PAP 1061 L=230 D201 SLR-325MC GREEN 1 2 D202 SLR-325DC 3 4 ORANGE D203 SLR-325MC GREEN 6 7 5V I C201 GP1UM261R VCC 2 OUT 1 GND 3 2010.09.07 5 C201 0.1 R201 47 <1/4W> + C202 47/ 10V 46 INDOOR UNIT COMPACT CASSETTE CONTROL UNIT AUYG07LVLA : EZ-01004HSE AUYG09LVLA : EZ-01005HSE AUYG12LVLA : EZ-01006HSE AUYG14LVLA : EZ-01007HSE AUYG18LVLA : EZ-01008HSE L CN8-1 CN8-2 CN7 B02B-XAYK-1-A CN7-1 CN7-2 CN5 B02B-XAKK-1-A CN5-1 CN5-2 WHITE YELLOW TEST BRANCH BOX UNIT POWER SOURCE AC230V 50Hz CN8 B02B-XASK-1-A CN2-1 CN2-2 CN2-3 CN2-4 CN2-5 CN2 B5P-SHF-1AA CN15-1 CN15-2 CN15-3 CN15-4 CN15-5 CN15-6 CN15 B06B-XASK-1-A N 2 SERIAL 3 TERMINAL HP-T3031-3-L1 RED W105 UL1015 AWG16 WHITE W102 UL1015 AWG20 DECORATION PANEL ASSEMBLY W101 CN3-1 CN3-2 CN3-3 CN3-4 CN3-5 CN3-6 WHITE E102 GREEN POWER SUPPLY PCB ASSEMBLY K06AL-1007HSE-P0 EMI FILTER ZCAT2132-1130 1T RED BLACK WHITE YELLOW BROWN CN105-6 CN105-5 CN105-4 CN105-3 CN105-2 CN105-1 CN105 B5P6-VH-B WHITE CN104 B08B-PASK-1 WHITE WHITE YELLOW YELLOW CN13-1 CN13-2 CN13-3 CN13-4 CN13-5 CN13-6 CN13-7 GRAY GRAY GRAY GRAY GRAY GRAY GRAY GRAY CN104-1 CN104-2 CN104-3 CN104-4 CN104-5 CN104-6 CN104-7 CN104-8 CN14 B03B-XAKK-1-A BLACK BROWN RED ORANGE YELLOW GREEN BLUE PURPLE 1 2 3 4 5 6 7 UL1430 AWG28 x7 1 2 3 4 5 6 7 CN201-1 CN201-2 CN201-3 CN201-4 CN201-5 CN201-6 CN201-7 BROWN RED ORANGE YELLOW GREEN BLUE PURPLE UL1430 AWG28 x7 CN201 S07B-PASK-2 WHITE UL1430 AWG22 UL1430 AWG22 WHITE CN14-3 UL1430 AWG22 BLACK EMI FILTER ZCAT1518-0730 2T TERMINAL HP-T3031-21 CN4-1 CN4-2 CN4-3 CN4-4 CN4-5 CN4-6 CN4-7 CN4-8 RED CN14-2 WHITE POWER DRIVE CN6 B02B-PAMK-1 CN6-1 CN10 B02B-PAOK-1 CN10-1 GREEN BLK WHT RED FRESH AIR ( OPTION ) CN6-2 CN4 B08B-PASK-1 WHITE UL1430 AWG26 x 8 UL1015 AWG22 x 5 UL1015 AWG18 UL1015 AWG18 CN3 B06B-PASK-1 INDICATOR PCB ASSEMBLY K06AG-1000HSE-D0 JUNCTION CONNECTOR XMR-07V CONTROLLER PCB ASSEMBLY ( MAIN PCB ) AUYG07LVLA : K06AK-1007HSE-C1 AUYG09LVLA : K06AK-1008HSE-C1 AUYG12LVLA : K06AK-1009HSE-C1 AUYG14LVLA : K06AK-100AHSE-C1 AUYG18LVLA : K06AK-100BHSE-C1 CN14-1 BLACK F101 AC250V 3.15A UL1015 AWG16 1 2 3 4 5 6 7 8 UL1015 AWG20 E101 GREEN M THERMISTOR (PIPE - MID. TEMPERATURE ) WHITE WHITE DRAIN PUMP GRAY GRAY BLACK CN13 B07B-PASK-1 UL1015 AWG20 FM THERMISTOR ( ROOM TEMPERATURE ) 1 E DC FAN MOTOR BLACK BLACK CN106-1 CN106-2 CN106 B2P3-VH-B-E BLUE CN101 B03B-PASK-1 WHITE DC SUPPLY CN101-1 CN101-2 CN101-3 GRAY GRAY GRAY CN1-1 CN1-2 CN1-3 CN1 B03B-PASK-1 ORANGE WIRED REMOTE CONTROL CN10-2 WHITE UL1430 AWG26 x 3 EMI FILTER ZCAT1518-0730 1T EXTERNAL OUT CN103-1 CN103-2 CN11 B05B-XASK-1-A CN103 B2B-XH-AM WHITE WHITE CN12 B05B-XARK-1-A RED CN11-1 CN11-2 CN11-3 CN11-4 CN11-5 CN12-1 CN12-2 CN12-3 CN12-4 CN12-5 RED ORANGE YELLOW PINK BLUE RED ORANGE YELLOW PINK BLUE M LOUVER ( UP / DOWN ) M LOUVER ( RIGHT / LEFT ) UL1430 AWG26 x 5 RED ORANGE YELLOW PINK BLUE RED ORANGE YELLOW PINK BLUE UL1430 AWG26 x 5 EXTERNAL I N CN102-1 CN102-2 CN102-3 CN102 B5P6-VH-B WHITE FLOAT SWITCH CN9 B03B-XARK-1-A RED 2010.09.02 47 CN9-1 CN9-2 CN9-3 UL1007 AWG24 BLACK UL1007 AWG24 BLACK INDOOR UNIT CONTROLLER PCB ASSEMBLY ( MAIN PCB ) AUYG07LVLA : K06AK-1007HSE-C1 AUYG09LVLA : K06AK-1008HSE-C1 AUYG12LVLA : K06AK-1009HSE-C1 AUYG14LVLA : K06AK-100AHSE-C1 AUYG18LVLA : K06AK-100BHSE-C1 ARYG07LLTA : K06AK-100CHSE-C1 ARYG09LLTA : K06AK-100DHSE-C1 ARYG12LLTA : K06AK-100EHSE-C1 ARYG14LLTA : K06AK-100FHSE-C1 ARYG18LLTA : K06AK-100GHSE-C1 D4 1SS355 13.5V CN1 B03B-PASK-1 5V DC SUPPLY 2 3 I R45 10k <1/10W> 12V O 3 G C1 + 10/ 50V JM1 C2 + 10/ 50V 2 C31 0.01 JM3 1 I 5V O 3 G 2 C32 + 100/ 6.3V R15 - R18 10k <1/10W> x 4 CN2 B5P-SHF-1AA C33 0.1 R46 1.0k <1/10W> FLOAT SWITCH 3 C8 - C10 0.1 x 3 5V C3 0.01 2 THERMISTOR ( ROOM TEMP. ) 2 C29 0.1 R57 1.0k <1/10W> R59 10k <1/10W> C30 0.1 R58 1.0k <1/10W> R60 49.9k <1/10W> C34 0.1 R62 1.0k <1/10W> R61 49.9k <1/10W> CN7 B02B-XAYK-1-A 1 2 CN5 B02B-XAKK-1-A 1 THERMISTOR ( PIPE - M I D. TEMP. ) 2 R4 - R6 1.0k <1/10W> x 3 5V CN8 B02B-XASK-1-A 1 CN9 B03B-XARK-1-A ( LF ) ( SN ) 1 JM2 D1 1SS355 I C2 NJM7805 5V R1 - R3 10k <1/10W> x 3 5V I C8 NJM7812 1 1 5V ABYG14LVTA : K06AK-100KHSE-C1 ABYG18LVTA : K06AK-100LHSE-C1 C28 0.1 5V 1 2 3 R19 - R22 1.0k <1/10W> x 4 1 FLASH 4 5 2 TEST CN15 B06B-XASK-1-A 5V R50 10k <1/10W> 6 3 4 5 C4 0.01 C5 1000p R24, R23, R32 5V 10k <1/10W> x 3 13.5V CN3 B06B-PASK-1 C7 1000p R66 10k <1/10W> R63 - R65 1.0k <1/10W> x 3 1 2 34 39 36 43 44 45 46 33 32 31 30 29 28 27 26 18 19 20 21 22 23 11 12 13 14 38 37 41 40 25 9 42 R70 10k <1/10W> 3 SP PCB 4 5 6 R67 1.0k <1/10W> 5V C37 0.1 C35, C12, C11 1000p x 3 R26 10k <1/10W> 3 C14 1000p R25 1.0k <1/10W> C36 0.47 Q3 DTC124EKA 1 2 5V R28 10k <1/10W> CN4 B08B-PASK-1 1 2 C15 0.01 5 6 C16 0.01 2 FRESH AIR CN10 B02B-PAOK-1 13.5V 2010.09.03 R68, R52 10k <1/10W> x 2 R43, R44 10k <1/10W> R41 x2 1.0k <1/10W> C38 0.1 R37 10k <1/10W> 1 2 3 6 2 5V VCC 8 DO 4 NC 7 GND 5 CS SK DI NC 3 4 C13 0.1 C23 0.01 C25 + 10/ 50V R42 47 C24 <1/10W> 1000p I C5 S-93C66BD0 I I C6-1 BA10393F - 6 7 5V + R55 10k <1/10W> 8 7 6 5 C17 0.01 R47 390 <1/10W> 3 1 R36 0R0 2 C19 - C22 0.1 x 4 C18 0.01 7 12V R54 15.4k <1/10W> D2 R53 12V DAN217U 28k <1/10W> 1 2 3 R48 10k <1/10W> B. Z. 4 R7 - R10 1.0k <1/10W> x 4 6 12V D3 D1FS4A CN14 B03B-XAKK-1-A ( LF ) ( SN ) 1 2 3 BZ1 PKM13EPYH-4000-A0 13.5V I C4 uLN2003ADR 1 2 3 4 5 6 7 I1 I2 I3 I4 I5 I6 I7 SK O1 O2 O3 O4 O5 O6 O7 GND 9 16 15 14 13 12 11 10 8 1 3 4 I1 I2 I3 I4 I5 I6 I7 LOUVER ( UP / DOWN ) 5 CN12 B05B-XARK-1-A 2 I C3 13.5V uPA2003ADR SK O1 O2 O3 O4 O5 O6 O7 GND CN11 B05B-XASK-1-A 2 1 9 16 15 14 13 12 11 10 8 REMOTE CONTROL UNIT R35 1.0k <1/10W> Q2 DTC124EKA 3 2 1 I NDICATOR PCB ASSY 3 2 R11 - R14 10k <1/10W> x 4 5 C26 0.01 5 I C6-1 BA10393F - 2 1 + 5V SW1 CFS-0402MC CN13 B07B-PASK-1 5V 1 R40 10k <1/10W> 3 4 1 2 3 4 5 6 7 5 1 HEATER 5V NC 13.5V R33 10k <1/10W> 1 2 VDD NC 3 1 OUT GND 4 2 R31 10k <1/10W> CN6 13.5V B02B-PAMK-1 C27 0.1 5V I C7 S-80842CNNB X1 8.00MHz 8 R34 1.0k R27 <1/10W> 330 <1/10W> R56 100k <1/10W> 1 Q1 DTC124EKA 7 5V JM5 0R0 35 10 24 15 16 17 57 58 59 60 61 62 63 64 1 2 3 4 5 6 7 8 53 54 55 56 47 48 49 50 51 52 R29 390 <1/10W> 1 4 POWER DRIVE AVREF AVDD VDD0 IC RST* VDD1 P00 P34 P01 P35 P02 P36 P03 P40 P41 P10 P11 P42 P43 P12 P13 P44 P14 P45 P15 P46 P16 P47 P50 P17 P51 P20 P21 P52 P22 P53 P23 P54 P55 P24 P25 P56 P30 P57 P31 P64 P32 P65 P33 P66 XT1 P67 XT2 P70 X1 P71 X2 P72 AGND P73 GND0 P74 GND1 P75 3 3 3 R69 10k <1/10W> I C1 uPD78F0536AGK 2 48 *LOUVER ( RIGHT / LEFT ) *The ARYG type is not used R103 62k 340V C108 4700p I C26-14 L R104 330k <2W> F101 3.15A 250V FH101 FH102 W101 BLACK 1 W102 L101 REP28-15 15mH, 1.1A LF101 ELF17N015A C104 0.47 4 SA101 RA-362M 4 C107 + 100/ 450V C106 0.010 3 2 R105 75 2 1 R107 100 <1/10W> D107 RD16 GREEN + C113 1000/ 25V R111 10k <1/10W> C114, C115 0.01 x2 D103 R108 D1FL20U 100 <1/2W> D104 D105 MTZJ5.1B D1FL20U C112 + 330/ 25V 3 D109 MTZJ5.1B R110 10k <1/10W> C118 0.01 E102 10 C110 0.047 3 Q102 2SC1815 12 D106 D1FL20U 1 R106 1.5 VA102 470V Q101 2SC5354 13.5V T101 ZFT22B03-C 2 3 5 6 7 8 D102 1SR139-600 15V C109 220p D101 D3SB60 2 3 C105 0.010 2 VA101 470V WHITE 1 D108 D2FL20U R109 C111 330 100/ + <1/4W> 25V A I C26-10 N E101 GREEN CN105 B5P-VH-B 340V 15V 6 5 4 5V 1 2 CN104 B08B-PASK-1 1 DC FAN MOTOR 3 A I C104 15V TLP621 R116 1.0k 4 <1/4W> IC105 2 HI2003R3 1 3 + C117 R117 820 100/ <1/4W> A A25V 4 3 I C103 TLP621 15V 18 8 1 2 R114 4.7k <1/10W> W105 R115 6.8k <1/4W> RED VA103 0.01 14 10 7 6 3 4 5 5 4 3 2 2 1 1 5V SERIAL INDOOR UNIT COMAPCT CASSETTE AUYG07LVLA AUYG09LVLA AUYG12LVLA AUYG14LVLA AUYG18LVLA 2 3 POWER DRIVE 4 5 6 I C26-14 I C26-10 L N 7 8 R113 330 <1/10W> 5V CN101 B03B-PASK-1 K101 G5N-1A 13.5V 2 3 C121 0.1 1 2 3 CN103 B2B-XH-AM 1 I C26-14 EXTERNAL OUT L L102 5V BLm18 C120 0.1 4 3 I C101 TLP621 R112 330 <1/10W> 2 N 3 1 1 I C26-10 CN102 B3B-XH-AM 2 L103 BLm18 2010.09.02 13.5V 2 1 DC SUPPLY 4 POWER SUPPLY PCB ASSEMBLY K06AL-1007HSE-P0 EXTERNAL I N C116 0.01 49 K102 G5NB-1A 3 2 1 4 CN106 B2P3-VH-B-E 13.5V 2 RC101 120/ 0.1 1 DRAIN PUMP INDOOR UNIT COMPACT CASSETTE AUYG07LVLA AUYG09LVLA AUYG12LVLA AUYG14LVLA AUYG18LVLA INDICATOR PCB ASSEMBLY ( OPTION ) K06AG-1000HSE-D0 5V TO CONTROLLER PCB ASSEMBLY ( MAIN PCB ) R201 220 <1/4W> CN201 S07B-PASK-2 ( LF ) ( SN ) R202 390 <1/4W> OPERATE 1 TIMER 2 FILTER CLEN / FILTER SIGN 3 5V 4 REMOTE CONTROL 5 GND 6 MANUAL AUTO SWITCH 7 R203 220 <1/4W> 2 4 D201 SLR-325MC GREEN D202 SLR-325DC ORANGE D203 SLR-325MC GREEN C202 + 10/ 25V 1 3 SW201 EVQPAG04K C201 0.1 PHA201 P I C-37143TH5 VCC 2 OUT 1 GND 3 2010.09.02 50 INDICATOR PCB ASSEMBLY ( SWITCH + DISPLAY ) K06DD-0801HSE-F0 22007 RED WIRED REMOTE CONTROL UNIT ( OPTION ) CN8-1 RED CN8-2 WHITE 2 CN8-3 BLACK 3 WHITE 1 4 CONTROLLER PCB ASSEMBLY ( MAIN PCB ) AGYG09LVCA : K09DD-0900HSE-C1 AGYG12LVCA : K09DD-1000HSE-C1 CN13 B05B-PH-K-S AGYG14LVCA : K09DD-1001HSE-C1 DAMPER M 1 CN2-2 ORANGE 2 CN2-3 YELLOW 3 CN2-4 PINK 4 CN2-5 BLUE 5 RED 1 2 LOUVER ( UP / DOWN ) DAMPER LOCK ( RIGHT ) DAMPER LOCK ( LEFT ) M M M CN5-2 ORANGE 3 CN5-3 YELLOW 4 CN5-4 PINK 5 CN5-5 BLUE 6 CN8-1 RED 1 CN8-2 ORANGE 2 CN8-3 YELLOW 3 4 CN8-4 PINK 5 CN8-5 BLUE 6 CN12-1 RED 1 CN12-2 ORANGE 2 CN12-3 YELLOW 3 CN12-4 PINK 4 CN12-5 BLUE 5 CN18 B04B-PASK WHITE CN14 B3B-XH-AM CN5 SJH20-06WS CN15 B3B-XH-AM-BK WHITE BLACK CN16 B3B-XH-AM-RK FM CN17-4 BLACK CN17-3 WHITE CN17-2 YELLOW CN17-1 BLUE 4 3 6 3 CN11-3 WHITE 7 2 CN11-2 WHITE 8 1 CN11-1 WHITE 9 CN201 JB20-09HG CN202 JB20-06HG RED WHITE 3 DC FAN MOTOR ( UPPER ) 1 CN18-1 BLACK 2 CN18-2 BLUE 3 CN18-3 BLACK 4 CN18-4 BLUE 6 CN12 B05B-PASK EXTERNAL I NPUT 1 ( OPTION ) 2 3 2010.09.06 FM 4 CN10-3 WHITE 3 CN10-2 YELLOW 2 CN10-1 BLUE 1 6 5 4 3 2 1 DISPLAY PCB ASSEMBLY 1 EXTERNAL I NPUT 2 ( OPTION ) 2 3 1 EXTERNAL I NPUT 3 ( OPTION ) 2 1 2 CN21 B2B-XH-AM-BK 1 BLACK WHITE CN17 B5 ( 7-5.6 ) B-XASK-1-A CN9 B07B-PASK WHITE EXTERNAL OUTPUT 1 ( OPTION ) EXTERNAL OUTPUT 2 ( OPTION ) 2 1 EXTERNAL OUTPUT 3 ( OPTION ) 2 1 CN13-1 2 CN13-2 3 CN13-3 FLASH 4 CN13-4 5 CN13-5 6 CN13-6 7 CN13-7 CN3 B02B-PASK 1 CN3-1 GRAY 2 CN3-2 GRAY CN1 2P-SAN 1 CN2-1 BLACK 2 CN2-2 BLACK WHITE 6 BLACK 5 CN203 JB20-06HG 1 WHITE 1 CN10-4 4 TEST 4 CN20 B2B-XH-AM 2 5 3 2 INDOOR UNIT FLOOR CONTROL UNIT AGYG09LVCA : EZ-0090BHSE AGYG12LVCA : EZ-01002HSE AGYG14LVCA : EZ-01003HSE THERMISTOR ( PIPE TEMPERATURE ) CN10-6 2 1 1 CN8 B06B-PASK 7 5 WHITE 3 6 DC FAN MOTOR ( LOWER ) CN11-4 RED RED RED 4 DAMPER LIMIT SWITCH ( OPEN ) CN2 SJH20-05WS CN22 B2B-XH-AM-RK CN17-7 5 DAMPER LIMIT SWITCH ( CLOSE ) WHITE CN5-1 4 WHITE WHITE WHITE RED WHITE CN11-5 5 CN6 B05B-XASK 5 CN2-1 CN11-6 WHITE SERIAL I N TM2 TERMINAL HP-T3064A-A28-L1 6 5 WHITE WHITE 3 CN201-6 3 CN11 B09B-PASK 22007 WHITE 2 WHITE WHITE SERIAL RED N IN TM1 WHITE CN11-7 CN201-5 WHITE CN11-8 WHITE 2 8 7 CN201-4 N POWER SOURCE AC230V 50Hz F1 AC250V 3.15A 1 WHITE BLACK RED CN201-3 1 CN11-9 WHITE 22007 BLACK L SWITCH PCB ASSEMBLY 9 CN201-2 L IN TM5 CN201-1 THERMAL FUSE 102 3A 250V WHITE CN10 B5 ( 6-5 ) B-XARK-1-A THERMISTOR ( ROOM TEMPERATURE ) RED WHITE 51 INDOOR UNIT FLOOR CONTROLLER PCB ASSEMBLY ( MAIN PCB ) AGYG09LVCA : K09DD-0900HSE-C1 AGYG12LVCA : K09DD-1000HSE-C1 AGYG14LVCA : K09DD-1001HSE-C1 T1 MY064 C10 0.01 340V TM5 L1 SS21V-R060330 3 4 F1 3.15A 250V POWER SOURCE AS230V 50Hz L2 20*20*18 0.6A 10mH C1 0.22 VA1 470V 4 C11 47p 1kV I C8 TOP244 D7 UF4007 2 6 5 4 18 14 C48 1000p TM2 R6 5.6k <1/10W> R7 270 <1/10W> D F S C27 0.22 A 5V C33 0.01 5V R46 470 <1/4W> R45 10k <1/10W> R44 390 <1/10W> 3 C32 0.01 2 Q10 RT1N241M C35 0.1 2 CN3 B02B-PASK-1 WHITE L6, L7 BLm18 x2 1 R23 10k <1/10W> 1% CN20 B2B-XH-AM WHITE R26 1.0k <1/10W> C37 0.1 EXTERNAL OUTPUT 1 ( OPTION ) K10 G5NB-1A 2 1 EXTERNAL OUTPUT 2 ( OPTION ) RED EXTERNAL OUTPUT 3 ( OPTION ) 1 2 3 4 1 2 3 4 1 1 CN9 B07BPASK-1 R25 49.9k <1/10W> 1% C38 0.1 5 4 I C1-6 12V R92 15.4k 12V <1/10W> 1% F2 0.2A 30V D2 D1F60 1 R90 10k <1/10W> JP5 0R0 R93 28k <1/10W> 1% 3 12V1 I C5-2 BA10393F 6 5 + 2 3 + 5V 7 R94 10k <1/10W> D3 DAN217U C47 0.1 1 I C5-1 BA10393F 15 2 I C1-42 I C1-43 I C1-44 I C1-45 I C1-46 I C1-21 I C1-22 I C1-23 I C1-24 I C1-26 I C1-27 I C1-28 I C1-29 R95 1.0k <1/10W> 2 R91 I C13-2 390 uLN2003ADR <1/4W> 1% 8 VCC I C1-25 5V I C18-1 I C5-3 BA10393F uLN2003ADR G/V I C1-39 4 1 I C1-55 R33 15V 10k 4 <1/10W> 1% 1 2 2 R32 15V 10k <1/10W> 4 1% 3 3 C46 1000p R36 1.0k <1/10W> C43 10/ 50V + R35 R31 I C10 8.2k 330 PS2561L-1-V <1/10W> 5V <1/10W> A A 1% 15V R39 10k <1/10W> I C1-41 C31 1000p 16 I C1-40 C45 1000p C59 1000p R37 1.0k <1/10W> 4 1 3 2 C52 0.1 1 3 2 I C1-79 2 R18 C17 +C30 1.0k 330/ 0.1 25V I C1-52 I C1-51 1 16 I C1-45 X1 8.00MHz I C7-8 uLN2003ADR 1 I C16-8 I C13-8 12V uLN2003ADR uLN2003ADR 9 9 9 9 VCC VCC VCC VCC G/V G/V G/V G/V 8 8 8 8 2 R66, R81 10k <1/10W> x2 R85 10k <1/10W> I C1-44 4 A 3 2 R42 R40 I C9 6.8k PS2561L-1-V 4.7k <1/10W> <1/4W> I C1-27 I C1-26 RED DC FAN MOTOR ( UPPER ) I C18-7 uLN2003ADR TEST I C7-1 uLN2003ADR 1 16 3 14 12V 1 I C7-3 uLN2003ADR 2 3 CN8 B06B-PASK-1 WHITE DAMPER LOCK ( RIGHT ) 4 6 11 I C7-5 uLN2003ADR 16 I C7-7 uLN2003ADR 1 5 5 12 6 3 7 10 2 15 2 3 14 I C16-2 uLN2003ADR 12 I C16-4 uLN2003ADR 5 10 I C16-6 uLN2003ADR 7 12 I C18-4 uLN2003ADR 10 I C18-6 uLN2003ADR I C1-29 I C18-5 I C1-28 uLN2003ADR 5 7 CN12 B05B-PASK-1 WHITE DAMPER LOCK ( LEFT ) 4 5 4 13 6 11 2 3 CN2 SJH20-05WS WHITE DAMPER 4 5 4 13 6 11 3 CN5 SJH20-06WS WHITE LOUVER ( UP / DOWN ) 4 5 6 5V 5V I C6 S-93C66B0 I R29 10k <1/10W> CN17 B5 ( 7-5.6 ) B-XASK-1-A I C1-33 WHITE DC FAN MOTOR ( LOWER ) C78 0.01 C74 0.01 C72 0.01 1 3 I C1-58 5V R79 10k <1/10W> R78 10k <1/10W> R77 10k <1/10W> CN18 B04B-PASK-1 WHITE DAMPER LIMIT SWITCH 4 C76, C77 0.1 x2 5V I C23 PS2561L-1-V 4 1 3 2 R75 L12 330 0R0 <1/10W> I C22 PS2561L-1-V 4 1 3 2 I C21 PS2561L-1-V 4 1 3 2 3 2 CN16 B3B-XH-AM-R RED 1 L13 0R0 5V R72 1.0k <1/10W> R105, R106 4.7k <1/10W> x2 2 5V R74 1.0k <1/10W> I C1-35 R103, R104 1.0k <1/10W> x2 I C1-57 I C1-70 I C1-73 I C1-71 I C1-72 8 VCC CS 1 4 DO DI 3 SK 2 7 NT 6 TEST GND 5 I C1-34 CN10 B5 ( 6-5 ) B-XARK-1-A I C16-5 uLN2003ADR WHITE 5 2 340V 52 13 4 CN13 B5B-PH-K-S 4 1 I C18-8 uLN2003ADR 1 I C14 R41 R43 PS2561L-1-V 4.7k 6.8k <1/10W> <1/4W> I C7-6 uLN2003ADR R76 1.0k <1/10W> 5 15V 1 I C7-4 uLN2003ADR 15 2 3 5V C61, C63 1000p x2 I C16-7 I C1-43 uLN2003ADR 340V 2 1 1 R87 10k <1/10W> I C1-77 I C1-76 I C1-75 3 9 2 BZ I C1-46 I C1-80 I C1-79 A C49 0.01 R69, R68, R67 10k <1/10W> x3 I C1-77 I C16-3 I C1-47 uLN2003ADR BZ1 I C13-1 uLN2003ADR PS1240P02BT 12V 3 4 C50 + 100/ 25V I C1-76 I C1-48 I C1-55 I C1-57 I C1-58 I C1-1 15V 8 C53 1000p 1 I C1-36 I C1-35 I C1-34 I C1-33 I C1-32 I C1-31 5 7 R63 - R65 330 <1/10W> x3 15V O 3 I C1-53 I C1-80 INDICATOR PCB ASSEMBLY 6 5V I C16-1 I C1-49 uLN2003ADR C44 10/ 50V 4 <1/10W> <1/10W> <1/10W> C51 0.1 I C1-50 + R34 R30 I C12 8.2k 330 PS2561L-1-V <1/10W> 5V <1/10W> A A 1% 15V R38 10k <1/10W> I C1-13 12V 1 14 3 I C1-75 R52 10k <1/10W> R22 10k 5V I C18-3 uLN2003ADR R51 0R0 G WHITE 5 R57 47 R58 1.0k R59 1.0k I C1-36 I C1-54 C58 0.1 I C1-9 12V 2010.09.07 I C1-61 I C1-40 I C1-25 I C1-9 I C1-8 C40 10k <1/10W> I C1-8 7 5 I C1-62 I C1-10 6 3 I C1-63 5V 3 1 I CN11 B09B-PAEK-1 4 I C1-1 C25, C26 0.1 x2 C23 0.1 I C1-5 I C13-3 uLN2003ADR 3 I C1-21 5V 5V 4 4 I C1-54 I C1-53 I C1-52 I C1-51 I C1-50 I C1-49 I C1-48 I C1-47 +C22 10/ 25V P00 VCC 19 P01 EVCC 20 P02 AVREF0 59 P03 AVREF1 56 P04 P51 42 P05 P52 43 P06 P53 44 P54 45 P10 P11 P55 46 P60 21 P12 P61 22 P13 P14 P62 23 P15 P63 24 P16 P64 26 P17 P65 27 P20 P66 28 P67 29 P21 P22 P70 37 P23 P71 36 P24 P72 35 P25 P73 34 P26 P74 33 P27 P75 32 P30 P76 31 P31 P77 30 P40 P90 55 P41 P110 57 P42 P111 58 P43 P120 1 P44 P121 15 P45 P122 14 P46 P123 12 P47 P124 11 P50 P130 69 *RESET P140 80 FLMD0 P141 79 P142 78 REGC GND P143 77 AGND P144 76 EGND P145 75 2 I C1-22 C14 + C21 330/ 0.1 25V I C20 78M15 JM9 0R0 20V 1 I C1-23 O 3 D14 1SS355 + I C13-4 uLN2003ADR 5 WIRED REMOTE CONTROL UNIT ( OPTION ) I C1-31 C56 0.47 R48 - R50 100 x 3 1 2 I C1-73 I C1-72 I C1-71 I C1-70 I C1-39 I C1-4 3 CN6 B05B-XASK-1-A I C1-42 74 73 72 71 70 39 38 54 53 52 51 50 49 48 47 68 67 66 65 64 63 62 61 40 25 9 8 7 6 5 4 3 2 41 10 13 16 17 60 18 I C1-2 I C1-41 I C1-10 I C1-13 R19 - R21 10k x 3 2 FLASH 7 IC1 uPD78F1154AGK I C13-5 uLN2003ADR 14 5V C16 100/ 50V G 2 R53 - R56 330 <1/10W> x4 I C1-2 C29 0.1 5V K12 G5NB-1A 1 D9 RF101L2S 1 I I C2 BA05T R13 47k <1/10W> 1% I C19 TL431 I LP I C1-32 12V 13 2 A 2 7V I C7-2 uLN2003ADR K11 G5NB-1A 2 1 CN22 B2B-XH-AM-R 3 R5 15k <1/10W> I C1-6 I C1-5 I C1-4 12 CN21 B2B-XH-AM-BK BLACK 2 4 2 + C15 47/ 35V 3 I C1-61 C36 0.1 2 THERMISTOR ( PIPE TEMP. ) 1 3 I C1-24 5V C20 0.1 R8 R9 1.8k 150 <1/10W> <1/10W> C19 0.1 R11 5.6k R12 200k <1/10W> <1/10W> C REF 1% 3 1 I C15 PS2561L-1-V Q7 2SA1037AK I C13-7 uLN2003 R24 1.0k <1/10W> 1 4 JM6 0R0 + C13 330/ 25V C28 0.01 5V A R47 390 <1/10W> 5 4 3 2 1 10 R80 470 <1/4W> 5V THERMISTOR ( ROOM TEMP. ) 1 + C18 47/ 35V 10 CN1 150-103-86172 D4 RF101L2S 2 C 1 L 2 X 3 8 9 10 R60 - R62 10k <1/10W> 5V x3 C41 1000p D15 1SS355 + C12 1000/ 25V D10 RF201L2S R4 12k <1/10W> IC26 HI2003R3 SERIAL 3 D6 D3SB60 C2 0.22 1 TM1 1 2 5 4 3 2 1 D8 1SS355 R82, R3 22 <1/4W> x2 + C9 68/ 420V 12V 6 R2 100k TP00351-31 x2 FH1 FH2 D12 RF201L2S 5V L10 0R0 R73 330 <1/10W> 3 2 1 L11 0R0 L3 5V 0R0 CN15 B3B-XH-AM-BK BLACK EXTERNAL I NPUT 2 C73 0.01 R70 330 <1/10W> 3 2 1 L4 0R0 EXTERNAL I NPUT 3 C75 0.01 C71 0.01 CN14 B3B-XH-AM WHITE EXTERNAL I NPUT 1 INDOOR UNIT FLOOR AGYG09LVCA AGYG12LVCA AGYG14LVCA INDICATOR PCB ASSEMBLY K06DD-0801HSE-F0 06 JB20 / JB20 1061 L60 5V D201 SLR-343DC 5V ORANGE CN203 D202, D203 SLR-343MC GREEN x2 5V I C201 GP1UM261 VCC 2 OUT 1 GND 3 09 PAP / JB20 1061 L550 R201 47 <1/4W> CN202 CN201 5V 6 1 9 5 2 8 4 3 7 3 4 6 2 5 5 1 6 4 3 2 + C202 47/ 10V SW201 KSHC611BT C201 0.1 3 2 1 SW202 SSSS213000 2010.09.06 5V 53 1 INDOOR UNIT SLIM DUCT CONTROL UNIT ARYG07LLTA : EZ-01009HSE ARYG09LLTA : EZ-0100AHSE ARYG12LLTA : EZ-0100BHSE ARYG14LLTA : EZ-0100CHSE ARYG18LLTA : EZ-0100DHSE CN8 B02B-XASK-1-A TEST TERMINAL HP-T3031-3-L1 POWER SOURCE AC230V 50Hz L 1 N 2 3 SERIAL UL1015 AWG20 BLACK UL1015 AWG20 WHITE UL1015 AWG20 RED W105 GREEN GREEN UL1015 AWG16 GREEN DC FAN MOTOR FM 1 2 3 4 5 6 7 8 RED BLACK WHITE YELLOW BROWN W102 W101 CN3-1 CN3-2 CN3-3 CN3-4 CN3-5 CN3-6 E102 CN105-6 CN105-5 CN105-4 CN105-3 CN105-2 CN105-1 CN5 B02B-XAKK-1-A CN5-1 CN5-2 POWER SUPPLY PCB ASSEMBLY K06AL-1008HSE-P0 CN105 B5P6-VH-B WHITE THERMISTOR ( PIPE - MID. TEMP. ) GRAY GRAY YELLOW WHITE CN15 B06B-XASK-1-A WHITE CN13 B07B-PASK-1 WHITE CN13-1 CN13-2 CN13-3 CN13-4 CN13-5 CN13-6 CN13-7 CONTROLLER PCB ASSEMBLY ( MAIN PCB ) ARYG07LLTA : K06AK-100CHSE-C1 ARYG09LLTA : K06AK-100DHSE-C1 ARYG12LLTA : K06AK-100EHSE-C1 ARYG14LLTA : K06AK-100FHSE-C1 ARYG18LLTA : K06AK-100GHSE-C1 INDICATOR PCB ASSEMBLY K04EI-1000HSE-D0 CN104 B08B-PASK-1 WHITE CN14 B03B-XAKK-1-A CN3 B06B-PASK-1 BLACK BROWN RED ORANGE WHITE BLUE PURPLE GRAY 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 UL1430 AWG28 x 7 Junction Connector XMR-08V 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 CN201-1 CN201-2 CN201-3 CN201-4 CN201-5 CN201-6 CN201-7 BROWN RED ORANGE WHITE BLUE PURPLE GRAY CN201 S07B-PASK-2 WHITE UL1430 AWG28 x 7 WHITE CN14-1 CN14-2 CN14-3 UL1430 AWG22 BLACK UL1430 AWG22 WHITE UL1430 AWG22 RED EMI FILTER ZCAT1518-0730 2T WHITE TERMINAL HP-T3031-21 POWER DRIVE CN104-1 CN104-2 CN104-3 CN104-4 CN104-5 CN104-6 CN104-7 CN104-8 GRAY GRAY GRAY GRAY GRAY GRAY GRAY GRAY CN4-1 CN4-2 CN4-3 CN4-4 CN4-5 CN4-6 CN4-7 CN4-8 CN6 B02B-PAMK-1 GREEN CN6-1 CN6-2 BLK WHT RED FRESH AIR ( OPTION ) CN4 B08B-PASK-1 WHITE UL1430 AWG26 x 8 EMI FILTER ZCAT2132-1130 1T DRAIN PUMP CN2 B5P-SHF-1AA E101 E103 CN7-1 CN7-2 WHITE CN15-1 CN15-2 CN15-3 CN15-4 CN15-5 CN15-6 F101 AC250V 5A UL1015 AWG16 CN7 B02B-XAYK-1-A BLACK BLACK Junction Connector XMR-08V E UL1015 AWG16 CN8-1 CN8-2 BLACK CN2-1 CN2-2 CN2-3 CN2-4 CB2-5 THERMISTOR ( ROOM TEMP. ) WHITE BLACK M BLACK CN106-1 CN106-2 UL1015 AWG18 x 2 CN106 B2P3-VH-B-E BLUE CN10 B02B-PAOK-1 DC SUPPLY CN101 B03B-PASK-1 WHITE CN101-1 CN101-2 CN101-3 GRAY GRAY GRAY CN1-1 CN1-2 CN1-3 CN1 B03B-PASK-1 ORANGE CN10-1 CN10-2 HEATER ( OPTION ) WIRED REMOTE CONTROL UNIT WHITE UL1430 AWG26 x 3 EXTERNAL OUT CN103-1 CN103-2 CN106 B2B-XH-AM CN11 B05B-XASK-1-A CN11-1 CN11-2 CN11-3 CN11-4 CN11-5 CN12 B05B-XARK-1-A CN12-1 CN12-2 CN12-3 CN12-4 CN12-5 WHITE REACTOR ASSY ( RELAY41-22 ) 2010.09.02 WHITE WHITE CN102-1 CN102-2 CN102-3 CN102 B3B-XH-AM CN108-1 CN108-2 CN108-3 CN106 B2P3-VH-B RED ORANGE YELLOW PINK BLUE M LOUVER UP / DOWN ( OPTION ) UL1430 AWG26 x 5 WHITE RED EXTERNAL I N RED ORANGE YELLOW PINK BLUE FLOAT SWITCH WHITE CN9 B03B-XARK-1-A RED CN9-1 CN9-2 CN9-3 BLACK BLACK UL1007 AWG24 x 2 WHITE 54 RECEIVER UNIT ( OPTION ) R103 62k 340V C108 4700p I C26-14 L R104 330k <2W> NORMAL COIL F101 5A 250V LF101 ELF20N030A 1 1 C104 0.22 4 SA101 RA-362M D101 D3SB60 2 R105 75 4 C107 + 270/ 450V C106 0.010 3 15V C109 220p 2 3 C105 0.010 2 C101 0.22 VA101 470V WHITE 2 1 BLACK W102 12 2 3 5 6 7 8 D102 1SR139-600 10 VA102 470V 2 1 R107 100 <1/10W> D107 RD16 GREEN C112 + 330/ 25V 3 D109 MTZJ5.1B R110 10k <1/10W> C118 0.01 E102 R111 10k <1/10W> E103 GREEN D103 R108 D1FL20U 100 <1/2W> D104 D105 MTZJ5.1B D1FL20U 3 R106 1.5 C113 1000/ 25V C110 0.047 1 Q102 2SC1815 + C114 0.01 D106 D1FL20U Q101 2SC5354 13.5V T101 ZFT22B03-C CN108 B2P3-VH-B FH101 FH102 W101 D108 D2FL20U R109 C111 330 100/ + <1/4W> 25V A I C26-10 N E101 GREEN CN105 B5P-VH-B 340V 15V 6 5 4 5V 1 2 CN104 B08B-PASK-1 1 I C104 15V TLP621 R116 1.0k 4 <1/4W> DC FAN MOTOR 3 A IC105 2 HI2003R3 1 3 + C117 R117 820 100/ <1/4W> A A25V 4 3 I C103 TLP621 15V 18 8 1 2 R114 4.7k <1/10W> W105 R115 6.8k <1/4W> RED VA103 0.01 14 10 7 6 3 4 5 5 4 3 2 2 1 1 5V INDOOR UNIT SLIM DUCT ARYG07LLTA ARYG09LLTA ARYG12LLTA ARYG14LLTA ARYG18LLTA SERIAL 2 3 POWER DRIVE 4 5 6 I C26-14 I C26-10 L N 7 8 POWER SUPPLY PCB ASSEMBLY K06AL-1008HSE-P0 R113 330 <1/10W> 5V CN101 B03B-PASK-1 K101 G5N-1A 13.5V 2 3 C121 0.1 2 3 CN103 B2B-XH-AM 1 I C26-14 EXTERNAL OUT L L102 5V BLm18 C120 0.1 4 3 2010.09.01 1 2 1 DC SUPPLY 4 13.5V I C101 TLP621 R112 330 <1/10W> 2 L103 BLm18 N 3 2 1 1 I C26-10 CN102 B3B-XH-AM EXTERNAL I N C116 0.01 55 K102 G5NB-1A 3 2 1 4 CN106 B2P3-VH-B-E 13.5V 2 RC101 120/ 0.2 1 DRAIN PUMP INDOOR UNIT SLIM DUCT ARYG07LLTA ARYG09LLTA ARYG12LLTA ARYG14LLTA ARYG18LLTA INDICATOR PCB ASSEMBLY ( OPTION ) K04EI-1000HSE-D0 5V CN201 08 / 08 JC25 / XMR ( OPERATE ) ( TIMER ) ( LOUVER ) ( LOUVER ) ( 5V ) BROWN RED 1 2 ORANGE 3 YELLOW 4 WHITE 5 ( REMOTE SIGNAL ) ( GND ) BLUE 6 PURPLE ( MANUAL AUTO SWITCH ) 7 GRAY 8 R201 330 <1/4W> D205 EMPG3863X GREEN R202 330 <1/4W> D206 EMAA3863X ORANGE R203 330 <1/4W> D207 EMPG3863X GREEN 1 3 C202 + 10/ 16V C201 0.1 2 4 SW201 EVQPAG04K VCC 2 OUT 1 GND 3 PHA201 PIC-37143TH5 2010.09.02 56 JM201 INDOOR UNIT FLOOR / CEILING CONTROL UNIT ABYG14LVTA : EZ-0100FHSE ABYG18LVTA : EZ-0100GHSE CN8 B2B-XASK-1-A GRAY GRAY THERMISTOR ( ROOM TEMP. ) WHITE CN7 B2B-XAYK-1-A THERMISTOR ( PIPE - ENT. TEMP. ) YELLOW CN5 B2B-XAKK-1-A BLACK BLACK THERMISTOR ( PIPE - MID. TEMP. ) BLACK INDICATOR PCB ASSEMBLY K04EI-1001HSE-D0 TERMINAL HP-T3031-3-L1 POWER SOURCE AC230V 50Hz 1 L N 2 SERIAL 3 UL1015 AWG20 RED UL1015 AWG20 WHITE UL1015 AWG20 BLACK CONTROLLER PCB ASSEMBLY ( MAIN PCB ) ABYG14LVTA : K06AK-100KHSE-C1 ABYG18LVTA : K06AK-100LHSE-C1 E CN13 B07B-PASK-1 WHITE W101 UL1015 AWG16 GREEN W102 E101 BLACK GREEN DC FAN MOTOR FM RED BLACK WHITE YELLOW BROWN DRAIN PUMP CN105 B5P6-VH-B CN104 B08B-PASK-1 WHITE WHITE CN104-1 CN104-2 CN104-3 CN104-4 CN104-5 CN104-6 CN104-7 CN104-8 GRAY GRAY GRAY GRAY GRAY GRAY GRAY GRAY CN4-1 CN4-2 CN4-3 CN4-4 CN4-5 CN4-6 CN4-7 CN4-8 CN6 B02B-PAMK-1 GREEN CN14-3 CN106-2 CN106 B2P3-VH-B-E BLUE CN6-1 CN6-2 CN103-1 CN10 B02B-PAOK-1 EXTERNAL I N 2011.01.06 CN102-2 CN102-3 WHITE RED UL1430 AWG22 WHITE UL1430 AWG22 BLACK CN103 B2B-XH-AM WHITE 3 2 1 CN10-1 CN10-2 HEATER EARTH WIRE DC SUPPLY CN101 B03B-PASK-1 CN101-1 CN101-2 CN101-3 GRAY GRAY GRAY CN1-1 CN1-2 CN1-3 CN1 B03B-PASK-1 WHITE FLOAT SWITCH WIRED REMOTE CONTROL UNIT CN9-1 CN9-2 CN9-3 CN9 B03B-XARK-1-A RED CN11 B05B-XASK-1-A WHITE CN102-1 UL1430 AWG22 TERMINAL EMI FILTER ZCA1518-0730 1T CN103-2 CN201 S08B-PASK-2 WHITE ORANGE WHITE EXTERNAL OUT CN201-1 CN201-2 CN201-3 CN201-4 CN201-5 CN201-6 CN201-7 CN201-8 FLESH AIR CN4 B08B-PASK-1 POWER SUPPLY PCB ASSEMBLY K06AL-1009HSE-P0 CN106-1 1 2 3 4 5 6 7 8 EMI FILTER ZCA1518-0730 2T POWER DRIVE CN105-6 CN105-5 CN105-4 CN105-3 CN105-2 CN105-1 1 2 3 4 5 6 7 8 CN14-1 CN14-2 E102 EMI FILTER ZCAT2132-1130 1T 1 2 3 4 5 6 7 8 RED ORANGE YELLOW WHITE BLUE PURPLE GRAY W105 CN14 B3B-XAKK-1-A UL1015 AWG16 CN13-1 CN13-2 CN13-3 CN13-4 CN13-5 CN13-6 CN13-7 CN12 B05B-XARK-1-A CN102 B3B-XH-AM RED WHITE 57 CN11-1 CN11-2 CN11-3 CN11-4 CN11-5 BROWN RED ORANGE YELLOW WHITE CN12-1 CN12-2 CN12-3 CN12-4 CN12-5 BROWN RED ORANGE YELLOW WHITE M LOUVER ( UP / DOWN ) M LOUVER ( LEFT / RIGHT ) R103 62k 340V C108 4700p I C26-14 L R104 330k <2W> F101 3.15A 250V FH101 FH102 W101 BLACK 1 W102 L101 REP-28-15 15mH, 1.1A LF101 ELF17N015A C104 0.47 4 SA101 RA-362M 4 C107 + 100/ 450V C106 0.010 3 2 R105 75 2 1 R107 100 <1/10W> D107 RD16 GREEN C112 + 330/ 25V + C113 1000/ 25V R111 10k <1/10W> C114, C115 0.01 x2 D103 R108 D1FL20U 100 <1/2W> D104 D105 MTZJ5.1B D1FL20U 3 D109 MTZJ5.1B R110 10k <1/10W> C118 0.01 E102 10 C110 0.047 3 Q102 2SC1815 12 D106 D1FL20U 1 R106 1.5 VA102 470V Q101 2SC5354 13.5V T101 ZFT22B03-C 2 3 5 6 7 8 D102 1SR139-600 15V C109 220p D101 D3SB60 2 3 C105 0.010 2 VA101 470V WHITE 1 D108 D2FL20U R109 C111 330 100/ + <1/4W> 25V A I C26-10 N E101 GREEN CN105 B5P-VH-B 340V 15V 6 5 4 5V 1 2 CN104 B08B-PASK-1 1 DC FAN MOTOR 3 A I C104 15V TLP621 R116 1.0k 4 <1/4W> IC105 2 HI2003R3 1 3 + C117 R117 820 100/ <1/4W> A A25V 4 3 I C103 TLP621 15V 18 8 1 2 R114 4.7k <1/10W> W105 R115 6.8k <1/4W> RED VA103 0.01 14 10 7 6 3 4 5 5 4 3 2 2 1 1 5V SERIAL 2 3 POWER DRIVE 4 5 6 I C26-14 I C26-10 L N INDOOR UNIT FLOOR / CEILING ABYG14LVTA ABYG18LVTA 7 8 POWER SUPPLY PCB ASSEMBLY K06AL-1009HSE-P0 R113 330 <1/10W> 5V CN101 B03B-PASK-1 K101 G5N-1A 13.5V 2 3 C121 0.1 2 3 CN103 B2B-XH-AM 1 I C26-14 EXTERNAL OUT L L102 5V BLm18 C120 0.1 4 3 I C101 TLP621 R112 330 <1/10W> 2 N 3 1 1 I C26-10 CN102 B3B-XH-AM 2 L103 BLm18 2010.10.12 13.5V 2 1 DC SUPPLY 4 1 EXTERNAL I N C116 0.01 58 K102 G5NB-1A 3 2 1 4 CN106 B2P3-VH-B-E 13.5V 2 RC101 120/ 0.1 1 DRAIN PUMP INDOOR UNIT FLOOR / CEILING ABYG14LVTA ABYG18LVTA INDICATOR PCB ASSEMBLY ( OPTION ) K04EI-1001HSE-D0 5V CN201 08 / 08 JC25 / XMR BROWN RED 1 2 ORANGE 3 YELLOW 4 WHITE 5 BLUE 6 PURPLE 7 GRAY 8 R202 330 <1/4W> D206 EMPG3863X GREEN R203 330 <1/4W> D207 EMAA3863X ORANGE R204 330 <1/4W> D208 EMPG3863X GREEN 1 3 C202 + 10/ 16V C201 0.1 2 4 SW201 EVQPAG04K VCC 2 OUT 1 GND 3 PHA201 PIC-37143TH5 2010.09.03 59 JM201 Error Code ERROR DETECTION E. 1 1. 3 Serial communication error OUTDOOR UNIT E. 1 1. 4 Serial communication error E. 1 5. 6 Check run unfinished E. 2 1. 2 Wiring mistake E. 2 2. 1 Indoor unit capacity error E. 2 4. 2 Connection unit number error (indoor unit) E. 2 4. 3 Connection unit number error (branch unit) E. 5 U. 1 Indoor unit error E. 6 2. 1 Outdoor unit PCB model information error E. 6 3. 1 Inverter error E. 6 4. 1 Active filter error, PFC circuit error E. 6 5. 3 Trip terminal L error E. 6 A. 1 Display PCB communication error E. 7 1. 1 Discharge thermistor error E. 7 2. 1 Compressor thermistor error E. 7 3. 3 Outdoor unit heat ex. liquid outlet thermistor error E. 7 4. 1 Outdoor thermistor error E. 7 5. 1 Suction gas thermistor error E. 7 7. 1 Heat sink thermistor error E. 8 2. 1 Sub cool heat ex. gas inlet thermistor error E. 8 2. 2 Sub cool heat ex. gas outlet thermistor error E. 8 3. 1 Liquid pipe thermistor error E. 8 4. 1 Current sensor error E. 8 6. 1 Discharge pressure sensor error E. 8 6. 3 Suction pressure sensor error E. 8 6. 4 High pressure switch error E. 9 4. 1 Trip detection E. 9 5. 1 Compressor rotor position detection error E. 9 7. 3 Outdoor unit fan motor error E. 9 9. 1 4-way valve error E. A 1. 1 Discharge temperature error E. A 3. 1 Compressor temperature error E. A 5. 1 Low pressure error E. J 2. U Branch boxes error LED display POWER MODE ERROR POWER MODE LED : on ERROR LED : blink POWER LED981 ON OFF LED981 LED982 (GREEN) (RED) 0.1sec LED962 LED961 ERROR LED982 0.1sec ON OFF Operation button MODE EXIT SW931 SELECT SW932 ENTER SW933 CHECK SW934 ERROR transition Annunciation "Err." and quantity are alternately shown. "ENTER" short press "ENTER" short press Type of errors ex : discharge thermistor abnormal ex : indoor unit abnormal Short press : less than 3 seconds Long press : more than 3 seconds If some error newly occurs or is resolved during transition, it is reflected after going back to "Annunciation". "SELECT" short press When there is more than one error, display is changed by "SELECT" short press. 2010.10.29 Error Contents 60 BRANCH BOX UTP-PY03A When an error occurs, an error description displays in the LED (No.401 - 405). Lit (n) Flashing (number of flashing) Unlit Green LED401 Red LED402 LED403 LED404 LED405 Comment Combination error Power supply frequency error Branch box identifying display (1) EEPROM access error (2) Model information error Serial communication error between Outdoor Unit and branch box Serial communication error between branch boxes Serial communication error between branch boxes Serial communication error between Indoor Unit A and branch box Serial communication error between Indoor Unit B and branch box Serial communication error between Indoor Unit C and branch box Indoor Unit A, liquid pipe thermistor error (CN309) Indoor Unit B, liquid pipe thermistor error (CN309) (3) (4) Primary unit : (1) (5) Secondary unit1 : (2) (6) Secondary unit2 : (3) (7) Indoor Unit C, liquid pipe thermistor error (CN310) Indoor Unit A, gas pipe thermistor error (CN309) Indoor Unit B, gas pipe thermistor error (CN309) Indoor Unit C, gas pipe thermistor error (CN310) Indoor Unit A, expansion valve full closure operation error (CN305) Indoor Unit B, expansion valve full closure operation error (CN306) Indoor Unit C, expansion valve full closure operation error (CN307) (8) (9) 2010.10.29 Remote control communication error 61 BRANCH BOX UTP-PY02A When an error occurs, an error description displays in the LED (No.401 - 405). Lit (n) Flashing (number of flashing) Unlit Green LED401 Red LED402 LED403 LED404 LED405 Comment Combination error Power supply frequency error (1) Branch box identifying display EEPROM access error Serial communication error between Outdoor Unit and branch box Serial communication error between branch boxes Serial communication error between branch boxes Serial communication error between Indoor Unit A and branch box Serial communication error between Indoor Unit B and branch box Indoor Unit A, liquid pipe thermistor error (CN309) Indoor Unit B, liquid pipe thermistor error (CN309) (3) (4) Primary unit : (1) Secondary unit1 : (2) Secondary unit2 : (3) (5) (6) Indoor Unit A, gas pipe thermistor error (CN309) Indoor Unit B, gas pipe thermistor error (CN309) Indoor Unit A, expansion valve full closure operation error (CN305) Indoor Unit B, expansion valve full closure operation error (CN306) (7) (8) (9) 2010.10.29 Remote control communication error 62 INDOOR UNIT Error Contents 2010.06.25 Operation LED Timer LED Economy LED Error Contents Operation LED Timer LED Serial Communication Error 1 times flash 1 times flash Continuous flash Wired Remote Controller Communication Error 8 times flash 2 times flash Continuous flash 1 times flash 2 times flash Continuous flash Sub-Cool Heat Ex.Gas Inlet Thermistor Error Sub-Cool Heat Ex.Gas Outlet Thermistor Error Check Run Unfinished 1 times flash 5 times flash Continuous flash Liquid Pipe Thermistor Error 8 times flash 3 times flash Continuous flash Number of Wires and Pipes Error 2 times flash 1 times flash Continuous flash Current Sensor Error 8 times flash 4 times flash Continuous flash Indoor Unit Capacity Error 2 times flash 2 times flash Continuous flash 8 times flash 6 times flash Continuous flash Connected Combination Error 2 times flash 3 times flash Continuous flash Discharge Pressure Sensor Error Suction Pressure Sensor Error High Pressure Switch Error Number of Indoor Units Error Number of Branch boxes Error 2 times flash 4 times flash Continuous flash Over Current Error 9 times flash 4 times flash Continuous flash Indoor Unit Model Information Error EEPROM Access Abnormal 3 times flash 2 times flash Continuous flash Compressor Control Error 9 times flash 5 times flash Continuous flash Manual Auto Switch Error 3 times flash 5 times flash Continuous flash Outdoor Unit Fan Motor Error 9 times flash 7 times flash Continuous flash Indoor Room Thermistor Error 4 times flash 1 times flash Continuous flash 4 Way Valve Error 9 times flash 9 times flash Continuous flash Indoor Heat Ex. Thermistor Error 4 times flash 2 times flash Continuous flash Discharge Temp. Error 10 times flash 1 times flash Continuous flash Indoor Unit Fan Motor Error 5 times flash 1 times flash Continuous flash Compressor Temp. Error 10 times flash 3 times flash Continuous flash Drainage Error 5 times flash 3 times flash Continuous flash Low Pressure Error 10 times flash 5 times flash Continuous flash Outdoor Unit Model Information Error 6 times flash 2 times flash Continuous flash Branch Boxes Error 13 times flash 2 times flash Continuous flash Inverter Error 6 times flash 3 times flash Continuous flash A. F. Voltage Error 6 times flash 4 times flash Continuous flash Flashing pattern example I.P.M. Error 6 times flash 5 times flash Continuous flash Indoor unit main PCB error (Operation LED : 3 times, Timer LED : 2 times) Display P.C.B. Communication Error 6 times flash 10 times flash Continuous flash Discharge Thermistor Error 7 times flash 1 times flash Continuous flash Compressor Thermistor Error 7 times flash 2 times flash Continuous flash Heat Ex. Liquid Outlet Thermistor Error 7 times flash 3 times flash Continuous flash Outdoor Thermistor Error 7 times flash 4 times flash Continuous flash Suction Gas Thermistor Error 7 times flash 5 times flash Continuous flash Heat Sink Thermistor Error 7 times flash 7 times flash Continuous flash Economy LED 1 cycle Operation LED Timer LED Economy LED 63 on off 1.0s 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s on 4.0s off on of 0.1s / 0.1s 3.0s 1.0s 0.5s 0.5s 0.5s 0.5s 1.0s 4.0s REMOTE CONTROL Error Code SIMPLE REMOTE CONTROLLER Error code If an error occurs, the following display will be shown. (“ “ will appear in the set room temperature display.) “ is displayed, immediately contact authorized If “ service personnel. Faulty unit No. (Remote controller address) Ex. Error code display WIRED REMOTE CONTROLLER If an error occurs, the following display will be shown. (“ “ will appear in the set room temperature display.) “ is displayed, immediately contact authorized If “ service personnel. Unit number (usually 0) Error code Ex. Error code display CENTRAL REMOTE CONTROLLER To show which indoor unit is the error displayed. indoor unit's name and "ERROR" are alternately shown. (0.5s indoor unit's name / 0.5s "ERROR") Ex. Error display 2010.06.25 64 Error Contents 1 1 Serial Communication Error 1 2 Wired Remote Controller Communication Error 1 5 Chech Run Unfinished 2 1 Number of Wires and Pipes Error 2 2 Indoor Unit Capacity Error 2 3 Error Code Error Contents 8 2 Sub-Cool Heat Ex.Gas Inlet Thermistor Error Sub-Cool Heat Ex.Gas Outlet Thermistor Error 8 3 Liquid Pipe Thermistor Error 8 4 Current Sensor Error Connected Combination Error 8 6 2 4 Number of Indoor Units Error Number of Branch boxes Error Discharge Pressure Sensor Error Suction Pressure Sensor Error High Pressure Switch Error 9 4 Over Current Error 3 2 Indoor Unit Model Information Error EEPROM Access Abnormal 9 5 Compressor Control Error Manual Auto Switch Error 9 7 3 5 Outdoor Unit Fan Motor Error Indoor Room Thermistor Error 9 9 4 1 4 Way Valve Error Indoor Heat Ex. Thermistor Error A 1 Discharge Temp. Error 4 2 Indoor Unit Fan Motor Error A 3 Compressor Temp. Error 5 1 Drainage Error A 5 Low Pressure Error 5 3 J 2 Branch Boxes Error 6 2 Outdoor Unit Model Information Error 6 3 Inverter Error 6 4 A. F. Voltage Error 6 5 I.P.M. Error 6 A Display P.C.B. Communication Error 7 1 Discharge Thermistor Error 7 2 Compressor Thermistor Error 7 3 Heat Ex. Liquid Outlet Thermistor Error 7 4 Outdoor Thermistor Error 7 5 Suction Gas Thermistor Error 7 7 Heat Sink Thermistor Error 7 1 PARTS 11 8 OUTDOOR UNIT AOYG45LAT8 6 9 2 10 2 Ref Description 3 Parts number 1 Top Panel Sub Assy 9379416009 2 Front Panel Sub Assy 9379418003 3 Service Panel Sub Assy 9379424004 4 Pipe Cover Front 9378861015 5 Right Panel Sub Assy 9379420006 6 Left Panel 9379431002 7 Protective Net (Rear) 9379404006 8 Protective Net (Left) 9379396004 9 Motor DC Brushless 9603013011 10 Propeller Fan 9379414005 11 Motor Bracket Sub Assy 9379429009 Rear Emblem 9380114000 -- 2010.10.29 5 4 65 OUTDOOR UNIT AOYG45LAT8 30 24 22 28 23 A 25 21 31 33 32 34 2010.10.29 27 View A 66 26 Ref Description Parts number 21 Base Assy 9379426008 22 Separate Wall Sub Assy 9379428002 23 Valve Plate 9379409001 24 Condenser A Sub Assy 9374420315 25 Compressor Cover A 9378611054 26 Compressor Cover B 9379974004 27 Compressor Cover C 9380399001 28 Compressor Cover Top 9379975001 29 Accumulator Cover 9379977005 30 Thermo Holder 9374177011 31 Holder (Accumulator) 9379762007 32 Holder (Sub Cool) A 9379674003 33 Holder (Sub Cool) B 9379675000 34 Rubber (Sub Cool) 9379676007 29 51 52 45 54 OUTDOOR UNIT AOYG45LAT8 46 43 41 53 42 65 44 47 Ref Description Parts number 50 41 Coil (Expansion Valve) 9970098031 56 42 Coil (Expansion Valve) 9970096068 43 Expansion Valve A Assy 9380060079 44 Expansion Valve B Assy 9380060086 45 4-way Valve Assy 9374425211 46 Solenoid (4-way Valve) 9970055072 47 Accumulator Sub Assy 9372700044 48 3-way Valve A Assy 9380032007 49 3-way Valve B Assy 9380031000 50 Compressor Assy 9374423248 51 Sensor (HP) 9900505059 52 Sensor (LP) 9900505066 53 Solenoid Valve Assy 9380016014 54 Solenoid (Solenoid Valve) 9900189228 55 Sub Cool HEx Sub Assy 9379051026 56 Belt Heater 9361140301 49 2010.10.29 48 67 72 OUTDOOR UNIT 69 67 71 68 65 70 61 73 64 63 62 74 (connector : white) 75 2010.10.08 76 (white) (white) 77 (white) 78 66 (white) 79 68 Ref Description Parts number 61 Controller PCB Assy 9708488028 62 Filter PCB Assy 9708500027 63 Inverter PCB Assy 9708497020 64 I/O PCB Assy 9708485027 65 ACTPM 9708590004 66 Terminal 9900428020 67 Choke Coil 9900592011 68 Heatsink A 9379787000 69 Heatsink B 9379788007 70 Case (Main) Assy 9380049012 71 Case (Inv) Assy 9380050001 72 Cover (Top) 9379774000 73 Cover (Front) Assy 9380068006 74 Cover (Terminal) 9379850001 75 Thermistor (Outdoor) 9900210052 76 Thermistor (Suction) 9900600006 77 Thermistor Assy (Heat Ex & Subcool Lo (Out)) 9900599003 78 Thermistor Assy (Subcool Lo (In) & Hi (Out)) 9900599010 79 Thermistor Assy (Discharge & Comp. Temp.) 9900598006 2 PARTS BRANCH BOX UTP-PY02A (2 branch) UTP-PY03A (3 branch) 1 3 4 UTP-PY02A 10 9 UTP-PY03A 13 10 13 11 11 8 Rubber (pipe hole) 12 Ref 5 6 2010.10.29 7 Description Parts number 1 Top Panel 9379775007 2 Hook Metal 9379778008 3 Insulation Box (Top) Sub Assy 9380102007 4 Top Case Sub Assy 9380108009 5 Bottom Case 9379789004 6 Insulation Box (Bottom) Sub Assy 9380103004 7 Bottom Panel 9379776004 8 Pipe Unit (UTP-PY02A) 9380055037 9 Pipe Unit (UTP-PY03A) 9380055020 10 EEV Coil A (Red) 9970106019 11 EEV Coil B (White) 9970106026 12 EEV Coil C (Green) (UTP-PY03A only) 9970106033 13 EEV Coil Bypass (Blue) 9970106040 -- Thermistor Assy A B (Red & White) 9900596002 -- Thermistor Assy C (Green) (03 only) 9900597009 69 24 BRANCH BOX UTP-PY02A (2 branch) 23 22 25 25 25 21 26 24 UTP-PY03A (3 branch) 23 22 25 25 25 21 26 Ref Description 2010.10.29 Parts number 21 Control Box Cover 9379781008 22 Control Box Assy 9380053002 23 Controller PCB Assy 9708741017 24 Terminal (Power) 9306489199 25 Terminal (Inner) 9306489182 26 Terminal (Remote) 9900567002 70 SEPARATION TUBE UTP-SX248A Branch Pipe A Sub Assy : 9371627069 Branch Pipe B Sub Assy : 9373161288 2010.10.29 71 PARTS INDOOR UNIT COMPACT WALL MOUNTED ASYG07LJCA ASYG09LJCA ASYG12LJCA 1 10 4 5 2 4 6 9 8 Ref 3 7 11 12 Description Parts number 1 Front Panel Total Assy 9318267051 2 Front Panel 9317642057 3 Intake Grille Assy 9318268034 4 Clamper Grille 9316906006 5 Air Filter 9317644013 6 Receiver Window 9317643016 7 Panel Cover 9317646017 8 Wire Cover 9317663007 9 Wire Shield 9317664011 10 Bracket Panel 9317665001 11 Remote Control 9379219006 12 Remote Control Holder 9305642045 Air Clean Filter Assy 9317250009 -2010.10.07 72 INDOOR UNIT COMPACT WALL MOUNTED ASYG07LJCA ASYG09LJCA ASYG12LJCA 21 24 26 25 23 22 Ref Description Parts number 21 Evaporator Total Assy 9317820011 22 Joint Pipe Assy 9317838009 23 Filter Guide 9317652001 24 Rear Bracket 9317651004 25 Evaporator Holder R 9317650007 26 Evaporator Holder L 9317649001 27 Holder (Room Thermistor) 9316895003 28 Thermistor Assy 9900563004 2010.10.08 27 73 28 47 48 33 INDOOR UNIT COMPACT WALL MOUNTED ASYG07LJCA ASYG09LJCA ASYG12LJCA 46 34 37 36 44 32 38 45 39 41 43 42 40 35 50 49 Ref 2010.06.29 Description 31 Parts number Ref 31 Casing Assy 9318264050 41 Gear A 9309994003 32 Casing 9317647014 42 Motor Step 9900384128 33 Motor Cover 9316568006 43 Drain Hose Assy 9316904002 34 Motor Cover 9316601000 44 Drain Cap 9316177017 35 Cable Guide 9316567009 45 Fan Guard 9332277005 36 Casing Cover B 9317653015 46 Fan Motor 9602704002 37 Casing Cover F 9317654005 47 Crossflow Fan Assy 9316830004 38 R AND L Louver B 9316961012 48 Bearing C Assy 9306628017 39 Louver Gear Holder 9317669016 49 Louver U 9317656016 40 Louver Gear 9317648004 50 Louver Z 9317657006 74 Description Parts number 52 INDOOR UNIT COMPACT WALL MOUNTED ASYG07LJCA ASYG09LJCA ASYG12LJCA 51 55 58 53 59 57 56 2010.10.08 Ref Description Parts number 51 Control Box 9318187007 52 Box Shield 9317575010 53 Control Cover 9317659017 54 Cover Shield 9317923002 55 Controller PCB Assy (07) 9708536088 55 Controller PCB Assy (09) 9708536095 55 Controller PCB Assy (12) 9708536101 56 Display Case 9317662000 57 Display PCB Assy 9707649024 58 Terminal 9900529017 59 Earth Terminal 9316586000 75 54 9 INDOOR UNIT WALL MOUNTED ASYG18LFCA ASYG24LFCA 4 6 8 6 2 5 7 3 Ref Description 11 10 Parts number 1 Front Panel Total Assy 9318738001 2 Front Panel 9314991080 3 Intake Grille Assy 9385985049 4 Air Filter 9315014016 5 Receiver Window 9315010018 6 Clamper Grille 9306755010 7 Wire Clamper 9315015013 8 Cap (Screw) 9309002050 9 Bracket Panel 9315023018 10 Remote Control 9379219037 11 Remote Control Holder 9305642045 Air Clean Filter Assy 9315212016 -2010.10.12 1 76 INDOOR UNIT WALL MOUNTED ASYG18LFCA ASYG24LFCA 32 25 26 28 27 24 22 23 21 29 30 31 2010.10.12 77 Ref Description Parts number 21 Evaporator Total Assy (18) 9315338075 21 Evaporator Total Assy (24) 9315338112 22 Connection Pipe Assy (18) 9315354020 22 Connection Pipe Assy (24) 9315355058 23 Water Seal 9315251015 24 Evaporator Holder R 9314994012 25 Evaporator Holder L 9314995019 26 Rear Bracket 9315022011 27 Filter Guide 9315013019 28 Filter Guard 9315411013 29 Bearing C Assy 9306628017 30 Crossflow Fan Assy 9315024015 31 Holder (Room Thermistor) 9315252012 32 Pipe Thermistor 9900551018 47 INDOOR UNIT WALL MOUNTED ASYG18LFCA ASYG24LFCA 43 44 48 46 49 55 53 45 51 50 42 56 58 52 Ref Description 2010.10.12 57 41 54 Parts number Ref Description Parts number 41 Casing Assy (18) 9315331038 51 Louver U 9315000019 41 Casing Assy (24) 9315331045 52 Louver Z 9315001016 42 Casing 9314993015 53 Diffuser U 9315002013 43 Casing Cover B 9315016010 54 Diffuser Z 9315003010 44 Casing Cover L 9315017017 55 Spring C 9314142017 45 Casing Cover R 9315018014 56 Piller A 9315009012 46 Casing Cover F 9315019011 57 Joint B 9315006011 47 Drain Cap 9367677009 58 R and L Louver 9311997016 48 Drain Hose Assy 9315769015 - Fan Guard 9305751051 49 Bush B 9312156016 - Fan Guard Holder Right 9315814012 50 Spacer B 9312441013 - Fan Guard Holder Left 9315815019 78 INDOOR UNIT WALL MOUNTED ASYG18LFCA ASYG24LFCA Ref Description 63 62 64 65 Parts number 61 Control Box Cover 9314997013 62 Control Box 9314996016 63 Controller PCB (18) 9708540030 63 Controller PCB (24) 9708540047 64 Terminal 9900447014 65 Terminal Earth 9315028020 66 Motor Case 9314998010 67 Fan Motor Assy 9602784004 68 Motor Step (Red) 9900384029 69 Motor Step (Green) 9900384036 70 Motor Step (Blue) 9900139063 71 Indicator PCB Assy 9707210057 67 66 68 71 70 69 61 2010.10.12 79 9 9 12 DECORATION PANEL UTG-UFYD-W 12 1 6 9 11 9 10 3 2 5 8 Ref. Description 7 4 2010.10.12 80 Part number 1 Decoration Panel without Insulations 9375525040 2 Display Panel 9375529123 3 Receiver Window 9375547011 4 Intake Grille Assy 9375726027 5 Intake Grille 9375531027 6 Long Life Filter 9375533014 7 Hook Bracket 9375546014 8 Grille Hook 9375532024 9 Panel Cover without Insulations 9375530013 10 Indicator PCB Assy 9707371031 11 Connector Cover 9375549015 12 Flap Total Assy 9377760029 DECORATION PANEL UTG-UFYD-W Flap total assy Motor holder assy 21 22 23 (connector : white) (connector : red) 2010.10.12 24 Ref. Description Part number 21 Gear A 9375536015 22 Motor Holder 9375535018 23 Step Motor (white connector) 9900139070 24 Step Motor (red connector) 9900139087 81 INDOOR UNIT COMPACT CASSETTE AUYG07LVLA AUYG09LVLA AUYG12LVLA AUYG14LVLA AUYG18LVLA 3 1 6 8 2 4 5 7 9 Ref. Description 10 2010.10.12 11 12 82 Part number 1 Top Plate Assy 9375490010 2 Cabinet A Assy 9375492014 3 Cabinet B 9375494018 4 Hook R 9375504014 5 Hook L 9375505011 6 Insulation Box Assy 9377764027 7 Wire Cover 9375516017 8 Pipe Cover 9375515010 9 Bell Mouse 9375503017 10 Wire Holder 9375478018 11 Drain Pan Sub Assy 9377765024 12 Drain Cap 9375502010 21 INDOOR UNIT COMPACT CASSETTE AUYG07LVLA AUYG09LVLA AUYG12LVLA AUYG14LVLA AUYG18LVLA 22 22 24 25 30 28 27 29 26 23 Ref. Description 2010.10.12 Part number 21 Evaporator Total Assy (07) 9375720087 21 Evaporator Total Assy (09, 12) 9375720032 21 Evaporator Total Assy (14, 18) 9375720070 22 Evaporator Holder 9375508012 23 2 Stage Turbo Fan Assy 9375480011 24 Fan Motor 9602436019 25 Fan Motor Holder 9375552015 26 Pump Assy 9900472030 27 Drain Pump Holder B 9375518011 28 Float Switch 9900361037 29 Drain Port Sub Assy 9375718015 30 Rubber (Pump) 9378426016 83 INDOOR UNIT COMPACT CASSETTE AUYG07LVLA AUYG09LVLA AUYG12LVLA AUYG14LVLA AUYG18LVLA Control unit 31 34 32 36 33 35 Ref. Description 2010.10.12 Part number 31 Control Box Cover 9375512019 32 Control Box A 9375511012 33 Controller PCB Assy (07) 9707393736 33 Controller PCB Assy (09) 9707393743 33 Controller PCB Assy (12) 9707393750 33 Controller PCB Assy (14) 9707393767 33 Controller PCB Assy (18) 9707393774 34 Power Supply PCB Assy 9707398250 35 Terminal 9306489045 36 Terminal 9703345012 -- Pipe Thermistor 9703297014 -- Room Thermistor 9900502003 -- Remote 9379219006 -- Remote Holder 9305642045 84 INDOOR UNIT FLOOR AGYG09LVCA AGYG12LVCA AGYG14LVCA 8 3 6 2 6 7 2 4 5 1 Ref Description 2010.10.13 Parts number 1 Intake Grille Assy 9316418059 2 Rope Assy 9316458017 3 Panel (Front) L 9316187016 4 Panel (Front) R 9316186019 5 Air Filter 9316189010 6 Air Clean Filter Assy 9316474017 7 Panel (Front) 9316185012 8 Bracket Panel 9316272019 -- Remote 9379219006 -- Remote Holder 9305642045 85 INDOOR UNIT FLOOR AGYG09LVCA AGYG12LVCA AGYG14LVCA 27 24 26 23 25 13 14 22 12 15 21 20 29 16 19 17 11 18 28 Ref Description Parts number Ref 11 Control Cover 9316201019 12 Controller PCB Assy (09) 12 30 25 Description Parts number 20 Display PCB Assy 9707571042 9708532011 21 Display Cover 9316191013 Controller PCB Assy (12) 9708532028 22 Thermistor Holder 9316192010 12 Controller PCB Assy (14) 9708532035 23 Room Thermistor 9700801108 13 Control Box 9316200012 24 Motor Holder 9316195011 14 Terminal 9900385026 25 Bearing C Assy 9306628017 15 Bracket (Terminal) 9316269019 26 Crossflow Fan Assy 9312004034 16 Cover (Terminal) 9316307018 27 Fan Motor, MFD-34TXN 9602850006 17 Bracket (Pipe) 9316270015 28 Crossflow Fan B Assy 9316309012 18 Pipe Thermistor 9900425012 29 Fan Motor, MFD-14SXN 9602851003 19 Display Case 9316194014 30 Base 9316193017 2010.10.29 86 INDOOR UNIT FLOOR AGYG09LVCA AGYG12LVCA AGYG14LVCA 32 31 33 Ref Description Parts number 31 Evaporator Total Assy (09, 12) 9316091016 31 Evaporator Total Assy (14) 9316091023 32 Evaporator Holder 9316199019 33 Water Seal 9316271012 2010.10.13 87 INDOOR UNIT FLOOR AGYG09LVCA AGYG12LVCA AGYG14LVCA Casing assy Ref Description Parts number 41 Top Cover 9316207011 42 R and L Louver U 9316208018 43 Fan Guard 9316211018 44 Casing 9316204010 45 Gear Case 9316213012 46 Gear A 9309994003 47 Motor Step (up / down) 9900384043 48 Louver U 9316205017 49 Louver Z 9316206014 50 REF (Casing) 9316378018 46 41 42 45 47 43 44 50 48 49 2010.10.13 88 52 54 51 55 53 56 58 INDOOR UNIT FLOOR AGYG09LVCA AGYG12LVCA AGYG14LVCA Casing aast 59 57 60 61 Ref Description Parts number 51 Motor Step (Damper) 9900384050 52 Switch Micro (Limit switch) 9900424015 53 Motor Step (Damper Lock Left) 9900384067 54 Drain Cap 9316177017 55 Drain Pan U 9316214019 56 Drain Hose Assy 9314147029 57 Motor Step (Damper Lock Right) 9900384074 58 Damper 9316216013 59 R and L Louver Z 9316334014 60 Drain Pan Z 9316215016 61 Stopper 9316219014 62 Cover (Lower) 9316374010 -- Fan Guard Z 9316918009 2010.10.13 62 89 9 1 15 10 8 2 6 16 4 7 5 3 14 13 INDOOR UNIT SLIM DUCT ARYG07LLTA ARYG09LLTA ARYG12LLTA ARYG14LLTA 12 11 Ref Description Parts number Ref Description Parts number 1 Side Panel R Sub Assy 9379906005 11 Main Panel Sub Assy 9379902007 2 Side Panel L Sub Assy 9379907002 12 Cabinet Panel (2 Fan) 9379596008 3 Pipe Panel Sub Assy 9379900003 13 Drain Cap 9358746004 4 Panel (Window) Sub Assy 9379915007 14 Drain Pan Sub Assy 9379901000 5 Outlet Frame Sub Assy 9379909006 15 Evaporater Total Assy (07) 9364499666 6 Front Panel (2 Fan) 9379593007 15 Evaporater Total Assy (09, 12) 9364499581 7 Valve Cover Sub Assy 9379576000 15 Evaporater Total Assy (14) 9364499673 8 Cover Pipe Sub Assy 9380033004 16 Pipe Thermistor 9900498085 9 Fan Guard (2 Fan) 9379637008 -- Hose Sub Assy 9378450103 10 Air Filter 2010.10.29 9379574006 90 29 INDOOR UNIT SLIM DUCT ARYG07LLTA ARYG09LLTA ARYG12LLTA ARYG14LLTA 21 32 28 35 33 34 23 24 26 28 30 27 23 25 26 22 2010.10.29 27 31 Ref Description Parts number Ref Description Parts number 21 Top Panel Sub Assy 9379908009 29 Hook Metal 9379889001 22 Separator Sub Assy 9379898003 30 Fan Motor Assy (07) 9602966011 23 Sirroco Fan Assy 9379570015 30 Fan Motor Assy (09, 12, 14) 9602967018 24 Motor Band Assy 9379613002 31 Room Thermistor 9703299247 25 Motor Band 9379614009 32 Drain Pump Sub Assy 9379914000 26 Rubber (Vibration Proof) 9379644006 33 Pump Assy 9900472047 27 Casing B 9379572002 34 Float Switch 9900465032 28 Casing U 9379571005 35 Drain Hose Assy 9379913003 91 9 1 10 8 6 2 15 4 16 5 7 3 14 9 INDOOR UNIT SLIM DUCT ARYG18LLTA 13 11 Ref Description 2010.10.13 Parts number Ref Description Parts number 1 Side Panel R Sub Assy 9379906005 10 Air Filter 9379575003 2 Side Panel L Sub Assy 9379907002 11 Main Panel Sub Assy 9379902014 3 Pipe Panel Sub Assy 9379900003 12 Cabinet Panel (3 Fan) 9379597005 4 Panel (Window) Sub Assy 9379915007 13 Drain Cap 9358746004 5 Outlet Frame Sub Assy 9379909013 14 Drain Pan Sub Assy 9379901017 6 Front Panel (3 Fan) 9379594004 15 Evaporator Total Assy 9364499604 7 Valve Cover Sub Assy 9379576000 16 Pipe Thermistor 9900498085 8 Cover Pipe Sub Assy 9380033004 -- Hose Sub Assy 9378450103 9 Fan Guard (3 Fan) 9379638005 92 INDOOR UNIT SLIM DUCT ARYG18LLTA 33 21 32 36 25 39 38 24 26 30 27 37 28 34 32 31 23 30 29 22 31 2010.10.13 35 Ref Description Parts number Ref Description Parts number 21 Top Panel Sub Assy 9379908016 31 Casing B 9379572002 22 Separator Sub Assy 9379898010 32 Casing U 9379571005 23 Sirroco Fan Assy 9379570022 33 Hook Metal 9379889001 24 Sirroco Fan Assy 9379570039 34 Fan Motor Assy 9602968015 25 Bracket (Bearing Sub Assy) 9379627009 35 Thermistor (Room) 9703299247 26 Shaft Assy 9379805001 36 Drain Pump Sub Assy 9379914000 27 Joint Assy 9378038011 37 Pump Assy 9900472047 28 Motor Band Assy 9379613002 38 Float Switch 9900465032 29 Motor Band 9379614009 39 Drain Hose Assy 9379913003 30 Rubber (Vibration Proof) 9379644006 93 INDOOR UNIT SLIM DUCT ARYG07LLTA ARYG09LLTA ARYG12LLTA ARYG14LLTA ARYG18LLTA Ref Description 43 44 Parts number 41 Control Cover Sub Assy 9379806039 42 Control Box Assy 9380041023 43 PCB Holder 9379402002 44 Power Supply PCB 9707398267 45 Controller PCB (07) 9707393781 45 Controller PCB (09) 9707393798 45 Controller PCB (12) 9707393804 45 Controller PCB (14) 9707393811 45 Controller PCB (18) 9707393828 46 Reactor Assy 9707457018 47 Terminal 3P 9306489045 48 Terminal 3P (Wired Remote) 9703345012 49 Terminal Bracket 9380132011 -- Wired Remote Control 48 41 49 42 2010.10.29 46 45 47 94 9318593013 INDOOR UNIT FLOOR CEILING ABYG14LVTA ABYG18LVTA 8 5 3 4 6 4 7 Ref. Description Part number 1 Remote 9379219037 2 Remote Holder 9305642045 3 Top Cover 9358534021 4 Arm 9358565001 5 Hanger Bracket L 9358596005 6 Hanger Bracket R 9358595008 7 Cosmetic Panel R 9358535028 8 Cosmetic Panel L 9358536025 2010.10.13 2 1 95 Insulation C 14 13 INDOOR UNIT FLOOR / CEILING ABYG14LVTA ABYG18LVTA Panel assy Insulation F Insulation D PCB holder 15 Insulation E 11 Ref. Description Part number 11 Panel 9358531259 12 Side Cover R Assy 9359069102 13 Indicator PCB Assy 9705798090 14 Insulation (Panel) A 9358574003 15 Insulation (Panel) B 9358914007 Panel Assy (with side cover R) 9359076322 -- 2010.10.13 12 96 INDOOR UNIT FLOOR / CEILING ABYG14LVTA ABYG18LVTA Grille 24 22 25 24 23 21 21 Ref. Description Part number 21 Air Filter 9358567029 22 Grill F 9358532027 23 Arm Bracket 9359281009 24 Grille Support 9358602003 25 Filter Bracket 9358607008 2010.10.13 97 33 INDOOR UNIT FLOOR / CEILING ABYG14LVTA ABYG18LVTA Kit (Flap base) 37 33 38 37 39 32 36 35 34 Ref. Description Part number 31 Kit (Flap Base) 9372670040 32 Flap Base 9358537022 33 Protect Cover 9358564011 34 Support Stay 9358599006 35 Louver 9358561027 36 Bushing B 9358554005 37 Louver Stopper 9358555002 38 Louver Rod 9358559017 39 Motor Rod 9358560013 2010.10.13 31 98 INDOOR UNIT FLOOR / CEILING ABYG14LVTA ABYG18LVTA Flap base sub assy 41 41 48 43 45 47 42 46 50 44 52 53 Ref. 2009.02.06 Description Part number 41 Bushing 9357942001 42 Bushing C 9358553008 43 Flap (Upper) F 9358538029 44 Kit (Flap Lower) 9372671023 45 Step Motor H 9900297015 46 Louver Link 9358556009 47 Louver Shaft 9358557006 48 Louver Link Cover 9358558010 49 Step Motor-V 9900362010 50 Motor Base 9358562017 51 Motor Rod-A (Step V) 9358550007 52 Flap Link-Upper (Step V) 9358551004 53 Flap Link-Lower (Step V) 9358552001 99 51 49 INDOOR UNIT FLOOR / CEILING ABYG14LVTA ABYG18LVTA Base assy 62 62 62 61 63 Ref. Description Part number 61 Base Assy 9359061014 62 Cap 9358563007 63 Base Bracket 9358586006 2010.10.13 62 100 72 73 78 74 75 76 77 79 37 71 Ref. Description Part number 71 Kit (Separate Wall A) 9372666012 72 Kit (Separate Wall B) 9373448013 73 Kit (Drain Pan Assy) 9372669013 74 Drain Cap 9358746004 75 Drain Hose Assy 9377785060 76 Kit (Insulation Flap Base) 9372672013 77 Kit (Dew Proof Plate) 9372673010 78 Catch 9359096009 79 Pipe Thermistor 9900022020 2010.10.13 INDOOR UNIT FLOOR / CEILING ABYG14LVTA ABYG18LVTA Drain pan assy Evaporator 101 INDOOR UNIT FLOOR / CEILING ABYG14LVTA Evaporator 84 82 81 83 ABYG18LVTA 82 81 83 84 Ref. 2010.10.13 Description Part number ABYG14LVTA ABYG18LVTA 81 Evaporator Assy 9362513029 9362513043 82 Bypass Pipe Assy 9373032014 9377819017 83 Distributor Assy 9373034018 9371325354 84 Coupling Pipe Assy 9373038061 9373038382 102 INDOOR UNIT FLOOR / CEILING ABYG14LVTA ABYA18LVTA Fan motor 93 97 98 93 98 91 94 95 95 91 92 Ref. Description Part number 91 Sirocco Fan Assy 9385258006 92 Casing 9358543009 93 Casing Cover 9358544006 94 Fan Motor Assy 9602401017 95 Rubber 9385102002 96 Motor Fixing Table 9358591000 97 Protector 9359282006 98 Motor Fixture 9358594001 2010.10.13 96 92 103 102 103 INDOOR UNIT FLOOR / CEILING ABYG14LVTA ABYG18LVTA Control unit 104 106 105 Ref. Description Part number 101 Control Box 9358600054 102 Control Box Cover Assy 9359097006 103 Controller PCB Assy (14) 9707393842 103 Controller PCB Assy (18) 9707393859 104 Power Supply PCB Assy 9707398274 105 Terminal 3P 9306489045 106 Terminal 3P 9703345012 -- Room Thermistor Assy 2010.10.29 101 9703299087 104 ACCESSORIES OUTDOOR UNIT Parts Q'ty Application Drain Assy 1 For outdoor unit drain piping work BRANCH BOX Parts number 9303029015 Parts Coupler heat insulation (large) Q'ty Application (PY03A) 4 (PY02A) 3 Drain Cap 2 313166024302 Coupler heat insulation (small) (PY03A) 4 (PY02A) 3 One-touch bush 2 Binder 3 For power supply cable and connection cable 9378779013 installation Insulation (long) For binding power cable and connection cable 9374688012 Insulation (short) (PY03A) 3 (PY02A) 2 Insulation 3 (PY03A) 3 (PY02A) 2 Hanger For indoor and outdoor side pipe joint (liquid pipe) 9378173521 For use on the section where the insulation fits onto this equipment. (indoor unit side) For use on the section where the insulation fits onto this equipment. (outdoor unit side) To be used with this equipment's (indoor unit side) piping 9375620028 9375620035 9379779005 9379778008 8 For suspending the Branch box from ceiling 0700132278 8 For installing the hanger (Ø 4×10) - Tapping screw 8 Binder 1 Seal 1 (PY03A) 3 (PY02A) 2 Adapter 2 105 9378173569 4 Tapping screw 2010.10.29 For indoor and outdoor side pipe joint (gas pipe) For suspending the Branch box from ceiling Washer Adapter Parts number For installing the branch box on the wall (Ø 4×25) For remote control cable binding To prevent small animals from entering inside - 313035356905 9380118008 For indoor unit connection 12.7 mm (1/2 inch) 9370244007 -> 9.52 mm (3/8 inch) For indoor unit connection 12.7 mm (1/2 inch) 9374749034 -> 15.88 mm (5/8 inch) INDOOR UNIT COMPACT WALL MOUNTED ASYG07, 09, 12LJCA Name and Shape WALL MOUNTED ASYG18, 24LFCA Q’ty Name and Shape Q’ty Wall hook bracket Wall hook bracket 1 1 Remote control 1 Remote control 1 Battery 1 Battery Remote control holder 2 1 Remote control holder Drain hose insulation 1 1 Cloth tape Cloth tape 1 1 Tapping screw (big) 8 Tapping screw (big) Tapping screw (small) 8 2 Tapping screw (small) Air cleaning filter 2 2 Air cleaning filter Air cleaning filter frame 2 2010.10.29 2 106 INDOOR UNIT COMPACT CASSETTE AUYG07, 09, 12, 14, 18LVLA Name and Shape Coupler heat insulation (Large) Coupler heat insulation Q’ty DECORATION PANEL UTG-UFYD-W Application Name and Shape 1 For indoor side pipe joint (Gas pipe) Connector cover 1 For indoor side pipe joint (Liquid pipe) Tapping Screw (M5 × 12 mm) 4 4 Template (Carton top) 4 Tapping Screw For installing indoor unit 1 L angle 2 1 For cealing openings cutting Also used as packing Hook wire 2 Drain hose For mounting decoration panel For installing indoor unit (M4 × 12 mm) Special nut B (Small ßange) For covering connector 1 (Small) Special nut A (Largeßange) Q’ty Application For installing drain pipe Screw [pitch small] (M4 × 10 mm) 1 For mounting connector cover For mounting the Hook Wire to the Decoration panel For suspending the Decoration panel For mounting the Hook Wire (for metals) 2 Hose Band For installing drain hose 1 Screw [pitch large] (M4 × 10 mm) Drain hose insulation 1 Remote controller For installing drain pipe For air conditioner operation 1 Battery 2 Remote controller holder 1 Tapping screw (M3 × 12mm) 2 Binder 2 Wire clamper 2010.10.29 1 For remote controller unit For installing the remote controller For mounting the remote controller holder For electrical wiring For electrical wiring 107 4 For mounting the L angle and Hook wire (for resins) INDOOR UNIT FLOOR AGYG09LVCA AGYG12LVCA AGYG14LVCA Name and Shape Q’ty Wall hook bracket 1 Remote control 1 Battery 2 Remote control holder 1 Cloth tape 1 Tapping screw (M4 x 25 mm) 9 Tapping screw (M3 x 12 mm) 2 Air cleaning filter 2 2011.01.07 108 INDOOR UNIT SLIM DUCT ARYG09LLTA ARYG12LLTA ARYG14LLTA ARYG18LLTA Name and Shape Q’ty Installation template Application For positioning the indoor unit 1 For installing indoor unit Washer 8 Coupler heat insulation (Large) 1 Coupler heat insulation (Small) Binder 1 Medium 3 For indoor side pipe joint (Small pipe) For power supply and remote control cable binding. 4 For fixing the coupler heat insulation. 2 (ARU9RLF ARU12RLF ARU24RLF) Large Filter (Small) Filter (Big) For indoor side pipe joint (Large pipe) 2 1 Drain hose 1 Hose band (ARU18RLF) (ARU24RLF) For installing drain pipe 3/4 in. (O.D. 1-1/16 in.) For installing drain hose 1 Drain hose insulation B Insulates the drain hose 1 Wired remote control 1 Remote control cable 1 Tapping screw (M4 × 16 mm) 2010.07.01 2 109 For connecting the remote control For installing the remote control INDOOR UNIT FLOOR / CEILING ABYG14LVTA ABYG18LVTA Name and Shape Q’ty screw (M4 × 10mm) Name and Shape Q’ty Installation template 2 1 Positioning for under ceiling type bracket (left) bracket (right) 1 1 For suspending the indoor unit from ceiling For suspending the indoor unit from ceiling Anchor bolt (M12) Spring washer For suspending the indoor unit from ceiling 4 Special nut For suspending the indoor unit from ceiling 4 For suspending the indoor unit from ceiling Wall bracket 4 screw(M4 × 20mm) For suspending the indoor unit on the wall 2 Coupler heat insulator (Large) 6 1 For indoor side pipe joint(Large pipe) For fixing the wall bracket Coupler heat insulator (Small) Binder(Large) 1 For indoor side pipe joint (Small pipe) 1 For fixing the drain hose Binder(Small) Wire clamper 2 1 For electrical wiring For electrical wiring Drain hose Hose Band 1 1 For installing drain hose insulation(Drain hose ) VT wire 1 1 Adhesive type 100 x 220(mm) For fixing the drain hose L 280mm Remote controller Battery 1 2 For air conditioner operation For remote controller Remote controller holder screw (M3 × 12mm) 1 2 For remote controller holder installation 2011.01.06 110 1009G3833