Transcript
Inductive sensor
NJ2-PD-E02-2.062-V95 Dimensions
LEDs
Ø48
35
2 x Ø6.5 Ø31.75
7/8"-16 Ø25
Model Number 37.5 26.5
34.5
NJ2-PD-E02-2.062-V95 Cylinder Position Switch
15.06
Features • • • •
"X"
4-wire DC Weld Immune Sensing range 2 mm 3000 psi rating
Ø12.7
Connection 1
L+
2
Technical Data General specifications Switching element function Rated operating distance Installation Output polarity Assured operating distance Reduction factor rAl Reduction factor r304 Nominal ratings Operating voltage Switching frequency Hysteresis Reverse polarity protection Short-circuit protection Voltage drop
4 5
L-
Pinout
1
5
2
Date of issue: 2013-01-21 904490_eng.xml Release date: 2013-01-21 09:49
Wire colors 1 2 4 5
WH RD OR BK
Accessories V95-G-YE2M-STOOW Female connector, 7/8" - 16 UNF, 5-pin, PUR cable
Subject to modifications without notice Pepperl+Fuchs Group USA: +1 330 486 0001 www.pepperl-fuchs.com
[email protected]
sa
UB f H
Ud
Operating current Off-state current
IL Ir
No-load supply current
I0
4 3
sn
Mag. Field strength, AC fields Mag. Field strength, DC fields Limit data Operating pressure dynamically Indicators/operating means LED green LED yellow Standard conformity Standards Ambient conditions Ambient temperature Mechanical specifications Connection type Protection degree Material Note Approvals and certificates UL approval CSA approval
Germany: +49 621 776-4411
[email protected]
NPN & PNP, NO 2 mm flush DC 0 ... 1.62 mm 0.4 0.85 10 ... 30 V DC 30 Hz 10 ... 20 typ. 15 % yes yes ≤ 2 V DC ≤ 200 mA ≤ 100 µA ≤ 35 mA 250 mT 100 mT 3000 psi Power on Output status EN 60947-5-2 -25 ... 70 °C (-13 ... 158 °F) Device connector 7/8"-16 UN , 5-pin IP67 Housing: zinc Probe: aluminum X = 2.062 in (52.4 mm) cULus Listed, General Purpose cCSAus Listed, General Purpose
Copyright Pepperl+Fuchs Singapore: +65 6779 9091
[email protected]
1
Inductive sensor NPT Type Mounting Holes: 1000 and 3000 psi NPT Types: Mounting hole screw thread shall be 1/4" - 20. Minimum thread engagement depth is 0.250" (6.35 mm) Hole spacing is 35 mm center to center.
Sensor through-hole
NJ2-PD-E02-2.062-V95
Mounting hole (x2)
Mounting hole spacing
Cylinder End-Cap Overhead View
Mounting Screws: Standard 1000 and 3000 psi models use two, self-locking 1/4"- 20 socket head cap screws (provided). Recommended tightening torque: 150 in lb (16.95 N-m).
Release date: 2013-01-21 09:49 Date of issue: 2013-01-21
904490_eng.xml
Important: When using spacers, make certain to maintain the 0.250" (6.35 mm) minimum mounting screw thread engagement.
2
Subject to modifications without notice Pepperl+Fuchs Group USA: +1 330 486 0001 www.pepperl-fuchs.com
[email protected]
Germany: +49 621 776-4411
[email protected]
Copyright Pepperl+Fuchs Singapore: +65 6779 9091
[email protected]