Preview only show first 10 pages with watermark. For full document please download

Industrial Detectors

   EMBED


Share

Transcript

Product Sheet | Detecon Industrial detectors Fire detectors for industrial risks UniVario FMX5000 IR 3-channel infrared Àame detector with three-way optics test for complete function monitoring. Very high responsivity and ¿ltering of interfrence such as sunlight and hot surfaces through intelligent evaluation algorithms UniVario FMX5000 UV Flame detector with spectral sensitivity in the ultraviolet range. High response sensitivity with monitoring area up to 676 m2. Interference such as cosmic radiation and thunderstorms (lightning) is ¿ltered out intelligent evaluation algorithms with integrated self-testing for monitoring the functionality (optical test). UniVario WMX5000 Heat detector with a robust stainless steel heat sensor. A microcontroller monitors the functionality and analyses data. The detector can be freely con¿gured for any application. For this, response temperatures, response classes and indices can be adjusted. Can be expanded by adding an LCD display. UniVario WMX5000 FS Heat detector for heavy-duty daily use with a robust stainless steel heat sensor rod or Àexible hose which protrudes from the enclosure. Thermoelectric sensors for response temperatures up to 850 °C (1562 °F). A microcontroller monitors the functionality and analyses data. Prominent response temperatures and all response classes can be freely con¿gured, along with rate-of-rise and static (¿xed temperature) response behaviour. Can be expanded by adding an LCD display. UniVario A family of industrial ¿re detectors based on a uniform platform. Highly variable, with a modular system for maximum adaptability. P31.312.000en / 02.14 Conventional detectors are available and can be changed to analog addressable detectors by adding the communication module KMX5000 AP / KMX5000 AP Ex. To achieve the best possible protection in each individual scenario, ¿re detectors of different designs and response sensitivity are used according to the requirements of each protected site. They work indoors and outdoors; in the direct vicinity of the protected site like UniVario WMX5000, or from further a¿eld like UniVario FMX5000 UV; in clean room environments as well as in extremely dirty process conditions. Equipped internally with the very latest advanced technology, they also feature a robust and attractive enclosure design. This new generation of high-tech ¿re detectors is substantially prefabricated, is easy and quick to install and can be easily integrated into existing solutions, making them an affordable alternative to conventional systems. One major advantage of the new range is their ability to forward detector data to databases for the purposes of analysis, maintenance or statistics compilation. Variations of UniVario detectors for conventional lines or analogue addressable systems are available, well graded for different hazard areas. The UniVario detector series with state of the art technology has big advantages due to lower installation costs in analogue addressable systems and increased safety due to permanent data transfer between control panel and detectors. © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 1 Product Sheet | Detecon Industrial detectors Fire detectors for industrial risks Overview accessories UniVario Bracket Console Base Base 3M16 Base LCD Base+Isolator Relay module Comms module Service device F FMX5000 IR FMX5000 IR HR Base HR Bracket HR F FMX5000 UV FMX5000 UVs F W WMX5000 WMX5000 FS WMX5000 FS Flex WMX5000 single hole W W F P31.312.000en / 02.14 WMX5000 VA W © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 2 Product Sheet | Detecon Industrial detectors Fire detectors for industrial risks Overview accessories UniVario Ex barrier Bracket Console Base Base Ex Comms Comms Service module module Ex device 3GD F FMX5000 IR 3GD *1 2G1D F FMX5000 IR Ex 3GD FMX5000 UV 3GD F *1 P31.312.000en / 02.14 *1) The service device should only be used outside of the explosion hazardous zone © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 3 Product Sheet | Detecon Industrial detectors Fire detectors for industrial risks Overview accessories UniVario Ex barrier Bracket Console Base Base Ex Comms Comms Service module module Ex device 3GD W WMX5000 3GD *1 2G1D W WMX5000 Ex 3GD W WMX5000 FS 3GD *1 2G1D W WMX5000 FS Ex 3GD W WMX5000 FS Flex 3GD *1 2G1D W WMX5000 FS Flex Ex 3GD WMX5000 single hole 3GD W *1 2G1D WMX5000 single hole Ex W P31.312.000en / 02.14 *1) The service device should only be used outside of the explosion hazardous zone © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 4 Product Sheet | Detecon Industrial detectors UniVario IR flame detector FMX5000 IR Order no.: 907481 Triple IR Àame detector for the detection of typical ¿res. Including 3 channel optic test monitoring all functional characteristics of detector. Designed for use in rough industrial environments. Equipped for operation as a conventional detector. Expansion to a detector with Loop AP protocol via KMX5000 AP communication module. Product features Optional accessories • Highly reliable against false alarms, e.g. from hot surfaces or sunlight. • A microcontroller monitors the functionality and analyses the recorded data. Faults can be indicated on the detector or on a separate line. Parallel indicator LMX5000 Weather protection MX5000 complete KMX5000 AP communication module Silicone-free design • Service interface, history memory. • Connection of remote indicator possible. • 3-channel optic test. 908499 910134 905883 Not included in delivery Base UniVario MX5000 Bracket MX5000 Terminating resistor 1.8 K / 0.5 W 904701 904757 675235 Connection / mounting Technical specifications Detection method Sensitivity class Viewing angle 1 90° Operating voltage 7.6 V - 30 V DC Quiescent current 2.3 mA Alarm current Alarm indication Fault indication current Fault indication Operating temperature IP rating (EN 60529) Enclosure material Relative humidity (IEC721-3-3) Speci¿cation according to P31.312.330 - 1en / 02.13 3 IR Sensors Weight Dimensions Connection cable standard detector 2-lead Additional fault line connection 2-lead External indication 2-lead Recommended cable JY (St) Y 2x2x0.8 mm (0.03 inch) Conductor cross-section max. 2.5 mm2 (0.004 square inch) Approvals / marking G 209141 0786-CPD-20784 approx. 15 mA 1 LED red approx. 15 mA 1 LED yellow -20 °C to +80 °C (-4 °F to +176 °F) IP 67 Diecast aluminium 0 to 95% no condensation EN 54 Part 10 820 g (1.8 lbs) 100 x 50 mm (dia. x H) 3.9 x 2 inch (dia. x H) © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 5 Product Sheet | Detecon Industrial detectors UniVario IR flame detector FMX5000 IR HR Art.-Nr.: 909404 Triple IR Àame detector for the detection of typical ¿res. Including 3 channel optic test monitoring all functional characteristics of detector. Variante HR (high ressistance) designed for use in highly rough industrial environments such as chemical industry. Designed for operation as a conventional detector. Expansion to a detector with Loop AP protocol via KMX5000 AP communication module. Product features Optional accessories • Highly reliable against false alarms, e.g. from hot surfaces or sunlight • A microcontroller monitors the functionality and analyses the recorded data. Faults can be indicated on the detector or on a separate line Parallel indicator LMX5000 Weather protection MX5000 complete KMX5000 AP communication module Silicone-free design • Service interface, history memory • Connection of remote indicator possible • 3-channel optic test Sensitivity class Viewing angle Operating voltage Quiescent current Alarm current Alarm indication Fault indication current Fault indication Operating temperature IP rating (EN 60529) P31.312.330 - 2en / 02.13 Enclosure material Relative humidity (IEC721-3-3) Speci¿cation according to Weight Dimensions Not included in delivery Base UniVario MX5000 HR Bracket MX5000 Mounting device bracked MX5000 HR Terminating resistor 1.8 K / 0.5 W 909406 904757 909359 675235 Connection / mounting Technical specifications Detection method 908499 910134 905883 3 IR Sensors 1 90° 7.6 V - 30 V DC 2.3 mA Connection cable standard detector 2-lead Additional fault line connection 2-lead External indication 2-lead Recommended cable JY (St) Y 2x2x0.8 mm (0.03 inch) Approvals / marking G 209141 0786-CPD-20784 approx. 15 mA 1 LED red approx. 15 mA 1 LED yellow -20 °C to +80 °C (-4 °F to +176 °F) IP 67 Diecast aluminium 0 to 95% no condensation EN 54 Part 10 820 g (1.8 lbs) 100 x 50 mm (dia. x H) 3.9 x 2 inch (dia. x H) © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 6 Product Sheet | Detecon Industrial detectors UniVario UV flame detector FMX5000 UV Order no.: 904702 UV Àame detector for the detection of typical ¿res. Including UV optic test monitoring all functional characteristics of detector. Designed for use in rough industrial environments. Designed for operation as a conventional detector. Expansion to a detector with Loop AP protocol via KMX5000 AP communication module. Product features Optional accessories • Parallel indicator Weather protection MX5000 complete KMX5000 AP communication module Silicone-free design • • • Highly reliable against false alarms, e.g. from lightning Àashes or strong sunlight. A microcontroller monitors the functionality and analyses the recorded data. Faults can be indicated on the detector or on a separate line. Service interface, history memory. Connection of remote indicator possible. Technical specifications Detection method Sensitivity class Viewing angle UV sensor 1 90° Operating voltage 7.6 V - 30 V DC Quiescent current approx. 0.25 mA Alarm current Alarm indication Fault indication current Fault indication Operating temperature IP rating (EN 60529) Enclosure material Relative humidity (IEC721-3-3) Speci¿cation according to Weight Not included in delivery Base UniVario MX5000 Bracket MX5000 Terminating resistor 1.8 K / 0.5 W Connection cable standard detector 2-lead Additional fault line connection 2-lead External indication 2-lead Recommended cable JY (St) Y 2x2x0.8 mm (0.03 inch) Conductor cross-section max. 2.5 mm2 (0.004 square inch) Approvals / marking 1 red LED approx. 15 mA 904701 904757 675235 Connection / mounting G 206132 0786-CPD-20286 1 yellow LED -20 °C to +80 °C (-4 °F to +176 °F) IP 67 Diecast aluminium 0 to 95% no condensation EN 54 Part 10 820 g (1.8 lbs) 100 x 50 mm (dia. x H) 3.9 x 2 inch (dia. x H) P31.312.310en / 02.13 Dimensions approx. 15 mA 908499 910134 905883 © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 7 Product Sheet | Detecon Industrial detectors UniVario UV flame detector FMX5000 UVs Order no.: 907375 UV Àame detector for the detection of typical ¿res. Designed for use in rough industrial environments. Designed for operation as a conventional detector. Expansion for a detector with Loop AP protocol via KMX5000 AP communication module. Product features Optional accessories • Parallel indicator Weather protection MX5000 complete KMX5000 AP communication module Silicone-free design • • • Highly reliable against false alarms, e.g. from lightning Àashes or strong sunlight. A microcontroller monitors the functionality and analyses the recorded data. Faults can be indicated on the detector or on a separate line. Service interface, history memory. Connection of external signal indication possible. Technical specifications Detection method Sensitivity class Viewing angle UV sensor 1 90° Operating voltage 7.6 V - 30 V DC Quiescent current approx. 0.25 mA Alarm current Alarm indication Fault indication current Fault indication Operating temperature IP rating (EN 60529) Enclosure material Relative humidity (IEC721-3-3) Speci¿cation according to Weight 1 red LED approx. 15 mA Not included in delivery Base UniVario MX5000 Bracket MX5000 Terminating resistor 1.8 K / 0.5 W 904701 904757 675235 Connection / mounting Connection cable standard detector 2-lead Additional fault line connection 2-lead External indication 2-lead Recommended cable JY (St) Y 2x2x0.8 mm (0.03 inch) Conductor cross-section max. 2.5 mm2 (0.004 square inch) Approvals / marking G 206132 0786-CPD-20286 1 yellow LED -20 °C to +80 °C (-4 °F to +176 °F) IP 67 Diecast aluminium 0 to 95% No condensation EN 54 Part 10 820 g (1.8 lbs) 100 x 50 mm (dia. x H) 3.9 x 2 inch (dia. x H) P31.312.310en / 02.13 Dimensions approx. 15 mA 908499 910134 905883 © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 8 Product Sheet | Detecon Industrial detectors UniVario Heat detectors, standard WMX5000 Order no.: 905441 The WMX5000 heat detectors are designed to detect open ¿res with rapid rise of temperature, e.g.: – Flammable liquids and gases – Highly Àammable plastics. They are designed speci¿cally for operation in polluted industrial environments, both indoors and outdoors. In addition to static temperature detection, rapid rises in temperature can also be registered by the rate-of-rise method, for early ¿re detection. Designed for operation as a conventional detector. Expansion to a detector with Loop AP protocol via KMX5000 AP communication module. Product features Optional accessories • Robust stainless steel heat sensor, resistant against impact and vibration. • Freely con¿gurable response temperatures and classes in accordance with EN54-5, along with rate-of-rise and static responses. Con¿guration via DIP switches on the detector. Detector remote indicator Weather protection MX5000 complete KMX5000 AP communication module Silicone-free design • Service interface, history memory. • Connection of remote indicator possible. Detection method NTC sensor Response classes Operating voltage A1, A2, B, C, indices S, R 0 °C to +90 °C (+32 °F to +194 °F) 7.6 V - 30 V DC Quiescent current approx. 0.15 mA Response temperatures Alarm current consumption Alarm indication Normal operation indication Current indication Fault indication Fault indication Operating temperature IP rating (EN 60529) Enclosure material Relative humidity (IEC721-3-3) Speci¿cation according to P31.312.110 - 1en / 02.14 Weight Dimensions Not included in delivery Base UniVario MX5000 Bracket MX5000 Terminating resistor 1.8 K / 0.5 W Technical specifications approx. 15 mA 904701 904757 675235 Connection / mounting Connection cable standard detector 2-lead Additional fault line connection 2-lead External indication 2-lead Recommended cable JY (St) Y 2x2x0.8 mm (0.03 inch) Conductor cross-section max. 2.5 mm2 (0.004 square inch) Approvals / marking 1 red LED 1 green LED, Àashing 801297 910134 905883 G 207090 0786-CPD-20280 approx. 15 mA 1 yellow LED (2nd line) -20 °C to +80 °C (-4 °F to +176 °F) IP 67 Diecast aluminium 0 to 95% no condensation EN 54 Part 5 520 g (1.2 lbs) 130 x 84 mm (dia. x H) 5.1 x 3.3 inch (dia. x H) WMX5000 CN Order no.: 909375 Version China Approvals / marking Technical data see Order no 905441 © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 9 Product Sheet | Detecon Industrial detectors UniVario Heat detectors, standard UniVario WMX5000 single hole Order no.: 905847 The single hole mounted WMX5000 heat detectors are speci¿cally designed for use in dryer and ventilation ducts for the detection of ¿res with rapid rise in temperature, e.g.: – Flammable liquids and gases – Highly Àammable plastics. In addition to ¿xed temperature detection, rapid rises in temperature can also be registered by the rate-of-rise method, for early ¿re detection. Designed for operation as a conventional detector. Expansion to a detector with Loop AP protocol via KMX5000 AP communication module. Product features Optional accessories • Robust stainless steel heat sensor, resistant to impact and vibration. • Freely con¿gurable response temperatures and classes in accordance with EN54-5, along with rate-of-rise and static responses. Con¿guration via DIP switches on the detector. Parallel indicator Weather protection MX5000 complete KMX5000 AP communication module Silicone-free design • Service interface, history memory. • Connection of remote indicator possible. Detection method NTC sensor Response classes Operating voltage A1, A2, B, C, D indices S, R 0 °C to +105 °C (+32 °F to +221 °F) 7.6 V - 30 V DC Quiescent current approx. 0.15 mA Response temperatures Alarm current consumption Alarm indication Normal operation indication Current indication Fault indication Fault indication Operating temperature IP rating (EN 60529) Enclosure material Relative humidity (IEC721-3-3) Speci¿cation according to P31.312.110 - 3en / 02.14 Weight Dimensions Not included in delivery Base UniVario MX5000 Single hole mounting ¿xture Single hole mounting tool Terminating resistor 1.8 K / 0.5 W Technical specifications approx. 15 mA 1 red LED 1 green LED, Àashing 908499 910134 905883 904701 800034 800388 675235 Connection / mounting Connection cable standard detector 2-lead Additional fault line connection 2-lead External indication 2-lead Recommended cable JY (St) Y 2x2x0.8 mm (0.03 inch) Conductor cross-section max. 2.5 mm2 (0.004 square inch) Approvals / marking G 207090 0786-CPD-20280 approx. 15 mA 1 yellow LED (2nd line) -20 °C to +80 °C (-4 °F to +176 °F) IP 67 Diecast aluminium 0 to 95% no condensation EN 54 Part 5 580 g (1.3 lbs) 130 x 133 mm (dia. x H) 5.1 x 5.2 inch (dia. x H) WMX5000 single hole CN Order no.: 909376 Version China Approvals / marking Technical data see Order no 905847 © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 10 Product Sheet | Detecon Industrial detectors UniVario High temperature heat detector FS WMX5000 FS 400°C (752 °F) Order no.: 905505 The WMX5000 FS high temperature heat detectors have been specially designed for operation in industrial environments with aggressive media and very high application temperatures in the monitoring area. For example in exhaust ducts, engine test stands or machine tools. In addition to ¿xed temperature detection, rapid rises in temperature can also be registered by the rate-of-rise method, for early ¿re detection. Designed for operation as a conventional detector. Expansion to a detector with Loop AP protocol via KMX5000 AP communication module. Product features Optional accessories • • Parallel indicator KMX5000 AP communication module Silicone-free design • • Robust stainless steel heat rod sensor Freely con¿gurable response temperatures and classes in accordance with EN54-5, along with rate-of-rise and static responses. Con¿guration via DIP switches on the detector. Service interface, history memory. Connection of remote indicator possible. Technical specifications Detection method Operating voltage PT1000 sensor A1, A2, B, C, D, E, F, G, indices S, R 0 °C to +400 °C (+32 °F to +752 °F) 7.6 V - 30 V DC Quiescent current approx. 0.25 mA Response classes Response temperatures Alarm current consumption approx. 15 mA Alarm indication 1 red LED Normal operation indication Current consumption Fault indication Fault indication 1 green LED, Àashing approx. 15 mA 1 yellow LED (2nd line) -20 °C to +80 °C (-4 °F to +176 °F) IP 67 Operating temperature IP rating (EN 60529) Enclosure material Relative humidity (IEC721-3-3) Speci¿cation according to Weight P31.312.130en / 02.14 Dimensions 908499 905883 Not included in delivery Base UniVario MX5000 Single hole mounting ¿xture Single hole mounting tool Terminating resistor 1.8 K / 0.5 W 904701 800034 800388 675235 Connection / mounting Connection cable standard detector 2-lead Additional fault line connection 2-lead External indication 2-lead Recommended cable JY (St) Y 2x2x0.8 mm (0.03 inch) Conductor cross-section max. 2.5 mm2 (0.004 square inch) Note The desired length of the sensor rod must be speci¿ed in millimetres at the time of placing the order. Alternatively, ¿xed standard rod lengths are available to choose from. Approvals / marking G 207091 0786-CPD-20281 Diecast aluminium 0 to 95% no condensation EN 54 Part 5 520 to 1600 g (1.2 to 3.5 lbs) 130 x 150 to 1500 mm (dia. x H) 5.1 x 5.9 x 59.1 inch (dia. x H) WMX5000 FS 400 °C (752 °F) CN Order no.: 909378 Version China Approvals / marking Otherwise like Order no 905505 © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 11 Product Sheet | Detecon Industrial detectors UniVario High temperature heat detector FS WMX5000 FS 400 °C 200 mm (752 °F 7.9 inch) Order no.: 906401 Version with ¿xed rod length of 200 mm (7.9 inch) Otherwise like Order no.: 905505 Technical specifications Response temperatures Weight Dimensions 0 °C to +400 °C (+32 °F to +752 °F) 680 g (1.5 lbs) 130 x 260 mm (dia. x H) 5.1 x 10.2 inch (dia. x H) WMX5000 FS 400 °C 400 mm (752 °F 15.8 inch) Order no.: 906402 Version with ¿xed rod length of 400 mm (15.8 inch) Otherwise like Order no.: 905505 Technical specifications Response temperatures Weight Dimensions 0 °C to +400 °C (+32 °F to +752 °F) 840 g (1.9 lbs) 130 x 460 mm (dia. x H) 5.1 x 18.1 inch (dia. x H) WMX5000 FS 400 °C 600 mm (752 °F 23.6 inch) Order no.: 906403 Version with ¿xed rod length of 600 mm (33.6 inch) Otherwise like Order no.: 905505 Technical specifications Response temperatures Weight P31.312.130en / 02.14 Dimensions 0 °C to +400 °C (+32 °F to +752 °F) 1000 g (2.2 lbs) 130 x 660 mm (dia. x H) 5.1 x 26 inch (dia. x H) © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 12 Product Sheet | Detecon Industrial detectors UniVario High temperature heat detector FS WMX5000 FS 850°C (1562 °F) Order no.: 906454 The WMX5000 FS high temperature heat detectors have been specially designed for operation in industrial environments with aggressive media and very high application temperatures in the monitoring area. For example in exhaust ducts, engine test stands or machine tools. In addition to ¿xed temperature detection, rapid rises in temperature can also be registered by the rate-of-rise method, for early ¿re detection. Designed for operation as a conventional detector. Expansion to a detector with Loop AP protocol via KMX5000 AP communication module. Product features Optional accessories • • Parallel indicator KMX5000 AP communication module • • Robust stainless steel heat rod sensor Freely con¿gurable response temperatures and classes in accordance with EN54-5, along with rate-of-rise and static responses. Con¿guration via DIP switches on the detector. Service interface, history memory. Connection of remote indicator possible. Technical specifications Detection method Operating voltage PT1000 sensor A1, A2, B, C, D, E, F, G, indices S, R 0 °C to +840 °C (+32 °F to +1544 °F) 7.6 V - 30 V DC Quiescent current approx. 0.35 mA Response classes Response temperatures Alarm current consumption Alarm indication Normal operation indication Current consumption Fault indication Fault indication Operating temperature IP rating (EN 60529) Enclosure material Relative humidity (IEC721-3-3) Speci¿cation according to Weight P31.312.130en / 02.14 Dimensions approx. 15 mA 1 red LED 1 green LED, Àashing 908499 905883 Silicone-free design Not included in delivery Base UniVario MX5000 Single hole mounting ¿xture Single hole mounting tool Terminating resistor 1.8 K / 0.5 W 904701 800034 800388 675235 Connection / mounting Connection cable standard detector 2-lead Additional fault line connection 2-lead External indication 2-lead Recommended cable JY (St) Y 2x2x0.8 mm (0.03 inch) Conductor cross-section max. 2.5 mm2 (0.004 square inch) Note The desired length of the sensor rod must be speci¿ed in millimetres at the time of placing the order. approx. 15 mA 1 yellow LED (2nd line) -20 °C to +80 °C (-4 °F to +176 °F) IP 67 Diecast aluminium 0 to 95% no condensation EN 54 Part 5 520 to 1600 g (1.2 to 3.5 lbs) 130 x 150 to 1500 mm (dia. x H) 5.1 x 5.9 x 59.1 inch (dia. x H) Approvals / marking © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 13 Product Sheet | Detecon Industrial detectors UniVario High temperature heat detector FS Flex WMX5000 FS Flex 400°C (752 °F) Order no.: 906176 The WMX5000 FS high temperature heat detectors have been specially designed for operation in industrial environments with aggressive media and very high application temperatures in the monitoring area. For example in exhaust ducts, engine test stands or machine tools. In addition to ¿xed temperature detection, rapid rises in temperature can also be registered by the rate-of-rise method, for early ¿re detection. Designed for operation as a conventional detector. Expansion to a detector with Loop AP protocol via KMX5000 AP communication module. Product features Optional accessories • • Parallel indicator KMX5000 AP communication module • • Robust Àexible stainless steel heat sensor Freely con¿gurable response temperatures and classes in accordance with EN54-5, along with rate-of-rise and static responses. Con¿guration via DIP switches on the detector. Service interface, history memory. Connection of remote indicator possible. Technical specifications Detection method Operating voltage PT1000 sensor A1, A2, B, C, D, E, F, G, indices S, R 0 °C to +400 °C (+32 °F to +752 °F) 7.6 V - 30 V DC Quiescent current approx. 0.25 mA Response classes Response temperatures Alarm current consumption Alarm indication Normal operation indication Current consumption Fault indication Fault indication Operating temperature IP rating (EN 60529) Enclosure material Relative humidity (IEC721-3-3) Speci¿cation according to Weight 1 red LED 1 green LED, Àashing approx. 15 mA 1 yellow LED (2nd line) -20 °C to +80 °C (-4 °F to +176 °F) IP 67 Diecast aluminium 0 to 95% no condensation EN 54 Part 5 Silicone-free design Not included in delivery Base UniVario MX5000 Holder WMX FS, from 250 °C (482 °F) to 600 °C (1112 °F) Terminating resistor 1.8 K / 0.5 W 904701 894679 675235 Connection / mounting Connection cable standard detector 2-lead Additional fault line connection 2-lead External indication 2-lead Recommended cable JY (St) Y 2x2x0.8 mm (0.03 inch) Conductor cross-section max. 2.5 mm2 (0.004 square inch) Note The desired length of the Àexible sensor rod must be speci¿ed in metres at the time of placing the order. The sensor rod holder is designed for application temperatures of up to 250 °C (482 °F). In case of higher application temperatures, the holder WMX FS from 250 °C (482 °F) to 600°C (1112 °F) Order no. 804679 is to be used. Approvals / marking G 207091 0786-CPD-20281 520 to 1600 g (1.2 to 3.5 lbs) 130 x 2000 to 9000 mm (dia. x H) 5.1 x 78.7 x 354.3 inch (dia. x H) P31.312.150en / 01.14 Dimensions approx. 15 mA 908499 905883 © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 14 Product Sheet | Detecon Industrial detectors UniVario High temperature heat detector FS Flex WMX5000 FS Flex 400 °C 2 m (752 °F 79 inch) Order no.: 906404 Version with Àexible hose of 2 m length (79 inch) Otherwise like Order no.: 906176 Technical specifications Response temperatures Weight Dimensions 0 °C to +400 °C (+32 °F to +752 °F) 680 g (1.5 lbs) 130 x up to 2000 mm (dia. x H) 5.1 x up to 78.73 inch (dia. x H) WMX5000 FS Flex 400 °C 6 m (752 °F 236 inch) Order no.: 906405 Version with Àexible hose of 6 m length (236 inch) Otherwise like Order no.: 906176 Technical specifications Response temperatures Weight Dimensions 0 °C to +400 °C (+32 °F to +752 °F) 840 g (1.9 lbs) 130 x up to 6000 mm (dia. x H) 5.1 x up to 236.2 inch (dia. x H) WMX5000 FS Flex 400 °C 9 m (752 °F 354 inch) Order no.: 906406 Version with Àexible hose of 9 m length (354 inch) Otherwise like Order no.: 906176 Technical specifications Response temperatures Weight P31.312.150en / 01.14 Dimensions 0 °C to +400 °C (+32 °F to +752 °F) 1000 g (2.2 lbs) 130 x up to 9000 mm (dia. x H) 5.1 x up to 354.3 inch (dia. x H) © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 15 Product Sheet | Detecon Industrial detectors UniVario High temperature heat detector FS Flex WMX5000 FS Flex 850°C (1562 °F) Order no.: 906455 The WMX5000 FS high temperature heat detectors have been specially designed for operation in industrial environments with aggressive media and very high application temperatures in the monitoring area. For example in exhaust ducts, engine test stands or machine tools. In addition to ¿xed temperature detection, rapid rises in temperature can also be registered by the rate-of-rise method, for early ¿re detection. Designed for operation as a conventional detector. Expansion to a detector with Loop AP protocol via KMX5000 AP communication module. Product features Optional accessories • • Parallel indicator KMX5000 AP communication module Silicone-free design • • Robust Àexible stainless steel heat sensor. Freely con¿gurable response temperatures and classes in accordance with EN54-5, along with rate-of-rise and static responses. Con¿guration via DIP switches on the detector. Service interface, history memory. Connection of remote indicator possible. Operating voltage PT1000 sensor A1, A2, B, C, D, E, F, G, indices S, R 0 °C to +840 °C (+32 °F to +1544 °F) 7.6 V - 30 V DC Quiescent current approx. 0.35 mA Response classes Response temperatures Alarm current consumption Alarm indication Normal operation indication Current consumption Fault indication Fault indication Operating temperature IP rating (EN 60529) Enclosure material Relative humidity (IEC721-3-3) Speci¿cation according to Weight P31.312.150en / 01.14 Dimensions Not included in delivery Base UniVario MX5000 Terminating resistor 1.8 K / 0.5 W 904701 675235 Connection / mounting Technical specifications Detection method 908499 905883 approx. 15 mA 1 red LED Connection cable standard detector 2-lead Additional fault line connection 2-lead External indication 2-lead Recommended cable JY (St) Y 2x2x0.8 mm (0.03 inch) Conductor cross-section max. 2.5 mm2 (0.004 square inch) Note The desired length of the Àexible sensor rod must be speci¿ed in metres at the time of placing the order. Approvals / marking 1 green LED, Àashing approx. 15 mA 1 yellow LED (2nd line) -20 °C to +80 °C (-4 °F to +176 °F) IP 67 Diecast aluminium 0 to 95% no condensation EN 54 Part 5 520 to 1600 g (1.2 to 3.5 lbs) 130 x 2000 to 9000 mm (dia. x H) 5.1 x 78.7 x 354.3 inch (dia. x H) © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 16 Product Sheet | Detecon Industrial detectors UniVario IR flame detector, Ex UniVario FMX5000 IR 3GD Order no.: 909481 Triple IR Àame detector for the detection of typcal ¿res. Including 3 channel optic test monitoring all functionalties of detector. ATEX-approved for category 3, Gas and Dust, suitable for use in Ex zones 2 and 22. The detector must not connected with a safety barrier and a blue ¿re alarm cable. Designed for use in rough industrial environments. Equipped for operation as a conventional detector. Expansion to a detector with Loop AP protocol via KMX5000 AP communication module. Product features Optional accessories • Highly reliable against false alarms, e.g. from hot surfaces or sunlight. • A microcontroller monitors the functionality and analyses the recorded data. Faults can be indicated on the detector or on a separate line. Parallel indicator LMX5000 KMX5000 AP communication module Weather protection MX5000 complete Silicone-free design • Service interface, history memory. • Connection of remote indicator possible. • 3-channel optic test. • For use in Ex zones 2 and 22, ATEX category 3 Gas/ Dust Sensitivity class Viewing angle 1 90° Quiescent current 2.3 mA Fault indication current Fault indication Operating temperature IP rating (EN 60529) Enclosure material Relative humidity (IEC721-3-3) Speci¿cation according to P31.312.340 - 1en / 01.14 3 IR Sensors 7.6 V - 30 V DC Alarm indication Weight Dimensions 904701 904757 675235 Connection / mounting Operating voltage Alarm current Not included in delivery Base UniVario MX5000 Bracket MX5000 Terminating resistor 1.8 K / 0.5 W Technical specifications Detection method 908499 905883 910134 approx. 15 mA 1 LED red Connection cable standard detector 2-lead Additional fault line connection 2-lead External indication 2-lead Recommended cable JY (St) Y 2x2x0.8 mm (0.03 inch) Conductor cross-section max. 2.5 mm2 (0.004 square inch) Note The detector will be delivered with two Ex cable glands. These cable glands have to be used at the base. Approvals / marking Ex conformity in acc. with 94/9/EG: x II 3G Ex nAc IIC T4 x II 3D Ex tc IIIC T110°C IP65 approx. 15 mA 1 LED yellow -20 °C to +80 °C (-4 °F to +176 °F) IP 67 Diecast aluminium 0 to 95% no condensation EN 54 Part 10 Type examination certi¿cate: BVS 11 ATEX E135 Ex conformity Russia in acc. with TP TC 012/2011: 1Ex ia IIC T6/T4 Gb 0Ex ia IIC T6/T4 Ga Ex ia IIIC T95°C Da G 209141 0786-CPD-20784 820 g (1.8 lbs) 100 x 50 mm (dia. x H) 3.9 x 2 inch (dia. x H) © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 17 Product Sheet | Detecon Industrial detectors UniVario IR flame detector, Ex FMX5000 IR Ex Order no.: 911674 Triple IR Àame detector for the detection of typical ¿res. Including 3 channel optic test monitoring all functionalties of detector. ATEX and IECEx approved for category 2 Gas and 1, 2 Dust, suitable for use in Ex zones 1, 20 and 21. The detectors must be connected via a safety barrier. Designed for use in tough industrial environments. Equipped for operation as a conventional detector. Extension to a detector with Loop AP protocol via the KMX5000 AP Ex. communication module. Product features Optional accessories • Highly reliable against false alarms, e.g. from hot surfaces or sunlight. • A microcontroller monitors the functionality and analyses the recorded data. Faults can be indicated on the detector or on a separate line. Safety barrier IS conventional 9 V Safety barrier IS addressable 24 V KMX5000 AP Ex communication module Weather protection MX5000 complete Silicone-free design • Service interface, history memory. Not included in delivery • Connection of remote indicator possible. • 3-channel optic test. • For use in Ex zones 1, 20 and 21, ATEX category 2 Gas/1, 2 Dust. Base UniVario MX5000 Ex Bracket MX5000 Terminating resistor 1.8 K / 0.5 W Sensitivity class Viewing angle Operating voltage Quiescent current Alarm current Alarm indication Fault indication current Fault indication P31.312.340 - 1en / 01.14 3 IR Sensors 1 7.6 V - 30 V DC 4.5 mA 1 LED red approx. 15 mA Enclosure material Relative humidity (IEC721-3-3) Speci¿cation according to Diecast aluminium 0 to 95% no condensation EN 54 Part 10 Dimensions Approvals / marking Ex conformity in acc. with 94/9/EG: x II 2G Ex ia IIC T6/T4 Gb x II 1D Ex ia IIIC T95°C Da approx. 15 mA IP rating (EN 60529) Weight Connection cable standard detector 2-lead Additional fault line connection 2-lead External indication 2-lead Recommended cable JY (St) Y 2x2x0.8 mm (0.03 inch) Conductor cross-section max. 2.5 mm2 (0.004 square inch) 90° 1 LED yellow -25 °C to +80 °C (-13 °F to +176 °F) IP 67 Operating temperature 912082 904757 675235 Connection / mounting Technical specifications Detection method 904991 901324 912086 910134 Type examination certi¿cate: BVS 12 ATEX E088 IECEx conformity: IECEx BVS 12.0056 Ex conformity Russia in acc. with TP TC 012/2011: 1Ex ia IIC T6/T4 Gb 0Ex ia IIC T6/T4 Ga Ex ia IIIC T95°C Da G 209141 0786-CPD-20784 860 g (1.9 lbs) 100 x 50 mm (dia. x H) 3.9 x 2 inch (dia. x H) © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 18 Product Sheet | Detecon Industrial detectors UniVario UV flame detector Ex FMX5000 UV 3GD Order no.: 907267 UV Àame detector for detection of typical ¿res. Designed for use in harsh industrial environments. Fitted for use as a conventional detector. The WMX5000 UV 3GD UV Àame detectors are Atex approved for Category 3 gas and dust and are intended for use in Ex Zones 2 and 22. Expansion to a detector with Loop AP protocol via the KMX5000 AP communications module. The Àame detector features a built-in optical channel function test. Product features Optional accessories • High degree of immunity against false alarms, such as storm lightning or strong sunlight. • Function monitoring and evaluation of measured values by microcontroller, faults can be displayed on the detector or a separate line. Parallel indicator LMX5000 KMX5000 AP communication module Weather protection MX5000 complete Silicone-free design • Service interface, history memory. • Connection of external display possible. • Use in Ex Zones 2 and 22 Atex Categorie 3 gas/dust. Not included in delivery Base UniVario MX5000 Bracket MX5000 Terminating resistor 1,8 K / 0,5 W Technical specifications Detection method Sensitivity class Viewing angle 1 90° Quiscent current approx. 0.25 mA approx. 15 mA Alarm indication 1 LED red Fault indication current ca. 15 mA Operating temperature IP rating (EN 60529) Enclosure material Relative humidity (IEC721-3-3) Speci¿cation according to Weight P31.312.320 - 1en / 01.14 UV-Sensor 7.6 V - 30 V DC Fault indication Dimensions 904701 904757 675235 Connection / mounting Operating voltage Alarm current 908499 905883 910134 1 LED yellow -20 °C to +80 °C (-4 °F to +176 °F) IP 67 Diecast aluminium 0 to 95% no condensation EN 54 Part 10 820 g (1.8 lbs) 100 x 50 mm (DxH) 3.9 x 2 inch (dia. x H) Connection cable standard detector 2-lead Additional fault line connection 2-lead External indication 2-lead Recommended cable JY (St) Y 2x2x0.8 mm (0.03 inch) Conductor cross-section max. 2.5 mm2 (0.004 square inch) Note The detector will be delivered with two Ex cable glands. These cable glands have to be used at the base. Approvals / marking Ex conformity in acc. with 94/9/EG: x II 3G Ex nAc IIC T4 x II 3D Ex tc IIIC T110°C IP65 EC type approval certi¿cate: BVS 11 ATEX E137 Ex conformity Russia in acc. with TP TC 012/2011: 2Ex nAc IIC T4 Ex tc IIIC T110°C IP65 applied fo © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | applied fo Chapter 6 - 19 Product Sheet | Detecon Industrial detectors UniVario Heat detectors, Ex standard WMX5000 3GD Order no.: 907268 The WMX5000 3GD heat detectors are ATEX-approved for category 3, gas and dust, and are suitable for use in Ex zones 2 and 22. They are designed to detect open ¿res with rapid rise of temperature, e.g.: – Flammable liquids and gases – Highly Àammable plastics. They are designed speci¿cally for operation in dirty industrial environments, both indoors and outdoors. In addition to stated temperature detection, rapid rises in temperature can also be registered by the rate-of-rise method, for early ¿re detection. Product features Equipped for operation as a conventional detector. Extension to a detector with Loop AP protocol via the KMX5000 AP communication module. • • Optional accessories • • • Robust stainless steel heat sensor. Freely con¿gurable response temperatures and classes in accordance with EN54-5, along with rate-of-rise and static responses. Setting via DIP switches on the detector or SMX5000 service device. Service interface, history memory. Connection of remote indicator possible. For use in Ex zones 2 and 22, ATEX category 3 Gas/ Dust. Technical specifications NTC sensor Response classes Operating voltage A1, A2, B, C, indices S, R 0 °C to +90 °C (+32 °F to +194 °F) 7.6 V - 30 V DC Quiescent current approx. 0.15 mA Alarm current consumption Alarm indication Normal operation indication Current indication Fault indication Fault indication Operating temperature IP rating (EN 60529) P31.312.120 - 1en / 01.14 Enclosure material Relative humidity (IEC721-3-3) Speci¿cation according to Weight Dimensions 908499 905883 Not included in delivery Base UniVario MX5000 Bracket MX5000 Terminating resistor 1.8 K / 0.5 W 904701 904757 675235 Connection / mounting Detection method Response temperatures Parallel indicator KMX5000 AP communication module Silicone-free design approx. 15 mA 1 red LED 1 green LED, Àashing approx. 15 mA 1 yellow LED (2nd line) -20 °C to +80 °C (-4 °F to +176 °F) IP 67 Connection cable standard detector 2-lead Additional fault line connection 2-lead External indication 2-lead Recommended cable JY (St) Y 2x2x0.8 mm (0.03 inch) Conductor cross-section max. 2.5 mm2 (0.004 square inch) Approvals / marking Ex conformity in acc. with 94/9/EC: x II 3G Ex nA II T4 x II 3D Ex tD A22 IP65 T110°C Type examination certi¿cate: BVS 07 ATEX E 156 Ex conformity Russia in acc. with TP TC 012/2011: 2Ex nAc IIC T4 Ex tc IIIC T110°C IP65 G 207090 0786-CPD-20280 Diecast aluminium 0 to 95% no condensation EN 54 Part 5 520 g (1.2 lbs) 130 x 84 mm (dia. x H) 5.1 x 3.3 inch (dia. x H) © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 20 Product Sheet | Detecon Industrial detectors UniVario Heat detectors, Ex standard WMX5000 Ex Order no.: 912117 The WMX5000 3 Ex heat detectors are ATEX and IECEx approved for category 2 gas and 1,2 dust, and are suitable for use in Ex zones 1, 20 and 21. They are designed to detect open ¿res with rapid rise of temperature, e.g.: – Flammable liquids and gases – Highly Àammable plastics. They are designed speci¿cally for operation in dirty industrial environments, both indoors and outdoors. In addition to stated temperature detection, rapid rises in temperature can also be registered by the rate-of-rise method, for early ¿re detection. Product features Equipped for operation as a conventional detector. Extension to a detector with Loop AP protocol via the KMX5000 AP Ex communication module. • • Optional accessories • • • Robust stainless steel heat sensor. Freely con¿gurable response temperatures and classes in accordance with EN54-5, along with rate-of-rise and static responses. Setting via DIP switches on the detector or SMX5000 service device. Service interface, history memory. Connection of remote indicator possible. For use in Ex zones 1, 20 and 21, ATEX category 2 Gas/1, 2Dust. Technical specifications Detection method NTC sensor Response classes Operating voltage A1, A2, B, C, indices S, R 0 °C to +90 °C (+32 °F to +194 °F) 7.6 V - 30 V DC Quiescent current approx. 2.8 mA Alarm current consumption approx. 15 mA Response temperatures Alarm indication Normal operation indication Current indication Fault indication Fault indication Operating temperature IP rating (EN 60529) P31.312.120 - 1en / 01.14 Enclosure material Relative humidity (IEC721-3-3) Speci¿cation according to Weight Dimensions 1 red LED 1 green LED, Àashing approx. 15 mA 1 yellow LED (2nd line) -25 °C to +80 °C (-13 °F to +176 °F) IP 67 Diecast aluminium 0 to 95% no condensation EN 54 Part 5 Safety barrier IS conventional 9 V Safety barrier IS addressable 24 V KMX5000 AP Ex communication module Weather protection MX5000 complete Silicone-free design 904991 901324 912086 910134 Not included in delivery Base UniVario MX5000 Ex Bracket MX5000 Terminating resistor 1.8 K / 0.5 W 912082 904757 675235 Connection / mounting Connection cable standard detector 2-lead Additional fault line connection 2-lead External indication 2-lead Recommended cable JY (St) Y 2x2x0.8 mm (0.03 inch) Conductor cross-section max. 2.5 mm2 (0.004 square inch) Approvals / marking Ex conformity in acc. with 94/9/EG: x II 2G Ex ia IIC T6/T4 Gb x II 1D Ex ia IIIC T95°C Da Type examination certi¿cate: BVS 12 ATEX E121 IECEx conformity: IECEx BVS 12.0074 Ex conformity Russia in acc. with TP TC 012/2011: 1Ex ia IIC T6/T4 Gb 0Ex ia IIC T6/T4 Ga Ex ia IIIC T95°C Da G 207090 0786-CPD-20280 520 g (1.2 lbs) 130 x 84 mm (dia. x H) 5.1 x 3.3 inch (dia. x H) © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 21 Product Sheet | Detecon Industrial detectors UniVario Heat detectors, Ex standard WMX5000 3GD single hole Order no.: 907269 The single hole mounted WMX5000 3GD heat detectors are ATEX-approved for category 3, gas and dust, and are suitable for use in Ex zones 2 and 22. They are speci¿cally suited for use in dryer and ventilation ducts for the detection of ¿res with rapid rise in temperature, e.g.: – Flammable liquids and gases – Highly Àammable plastics. In addition to stated temperature detection, rapid rises in temperature can also be registered by the rate-of-rise method, for early ¿re detection. Equipped for operation as a conventional detector. Extension to a detector with Loop AP protocol via the KMX5000 AP communication module. Product features • • • • • Robust stainless steel heat sensor, resistant against impact and vibration. Freely con¿gurable response temperatures and classes in accordance with EN54-5, along with rate-of-rise and static responses. Con¿guration via DIP switches on the detector or SMX5000 service device. Service interface, history memory. Connection of remote indicator possible. For use in Ex zones 2 and 22, ATEX category 3, Gas/ Dust. Technical specifications Detection method NTC sensor Response classes Operating voltage A1, A2, B, C, D, indices S, R 0 °C to +105 °C (+32 °F to +221 °F) 7.6 V - 30 V DC Quiescent current approx. 0.15 mA Response temperatures Alarm current consumption Alarm indication Normal operation indication Current indication Fault indication Fault indication Operating temperature IP rating (EN 60529) P31.312.120 - 2en / 01.14 Enclosure material Relative humidity (IEC721-3-3) Speci¿cation according to Weight Dimensions approx. 15 mA 1 red LED 1 green LED, Àashing approx. 15 mA 1 yellow LED (2nd line) -20 °C to +80 °C (-4 °F to +176 °F) IP 67 Optional accessories Parallel indicator Weather protection MX5000 complete KMX5000 AP communication module Silicone-free design 908499 910134 905883 Not included in delivery Base UniVario MX5000 Single hole mounting ¿xture Single hole mounting tool Terminating resistor 1.8 K / 0.5 W 904701 800034 800388 675235 Connection / mounting Connection cable standard detector 2-lead Additional fault line connection 2-lead External indication 2-lead Recommended cable JY (St) Y 2x2x0.8 mm (0.03 inch) Line cross-section max. 2.5 mm2 (0.004 square inch) Approvals / marking Ex conformity in acc. with 94/9/EC: x II 3G Ex nA II T4 x II 3D Ex tD A22 IP65 T110°C Type examination certi¿cate: BVS 07 ATEX E 156 Ex conformity Russia in acc. with TP TC 012/2011: 2Ex nAc IIC T4 Ex tc IIIC T110°C IP65 G 297090 0786-CPD-20280 Diecast aluminium 0 to 95% no condensation EN 54 Part 5 580 g (1.3 lbs) 130 x 133 mm (dia. x H) 5.1 x 5.2 inch (dia. x H) © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 22 Product Sheet | Detecon Industrial detectors UniVario Heat detectors, Ex standard WMX5000 Ex single hole Order no.: 912118 The single hole mounted WMX5000 Ex heat detectors are ATEX-approved for category 2, gas and 1, 2 dust, and are suitable for use in Ex zones 1, 20 and 21. They are speci¿cally suited for use in dryer and ventilation ducts for the detection of ¿res with rapid rise in temperature, e.g.: – Flammable liquids and gases – Highly Àammable plastics. In addition to stated temperature detection, rapid rises in temperature can also be registered by the rate-of-rise method, for early ¿re detection. Equipped for operation as a conventional detector. Extension to a detector with Loop AP protocol via the KMX5000 AP Ex communication module. Product features • • • • • Robust stainless steel heat sensor, resistant against impact and vibration. Freely con¿gurable response temperatures and classes in accordance with EN54-5, along with rate-of-rise and static responses. Con¿guration via DIP switches on the detector or SMX5000 service device. Service interface, history memory. Connection of remote indicator possible. For use in Ex zones 1, 20 and 21, ATEX category 2, Gas/ 1, 2 Dust. Technical specifications NTC sensor Response classes Operating voltage A1, A2, B, C, D, indices S, R 0 °C to +105 °C (+32 °F to +221 °F) 7.6 V - 28 V DC Quiescent current approx. 3.0 mA Alarm current consumption approx. 15 mA Alarm indication Normal operation indication Current indication Fault indication Fault indication Operating temperature P31.312.120 - 2en / 01.14 IP rating (EN 60529) Enclosure material Relative humidity (IEC721-3-3) Speci¿cation according to Weight Dimensions Safety barrier IS conventional 9 V Safety barrier IS addressable 24 V KMX5000 AP Ex communication module Silicone-free design 904991 901324 912086 Not included in delivery Base UniVario MX5000 Ex Single hole mounting ¿xture Single hole mounting tool Terminating resistor 1.8 K / 0.5 W 912082 800034 800388 675235 Connection / mounting Detection method Response temperatures Optional accessories Connection cable standard detector 2-lead Additional fault line connection 2-lead Recommended cable JY (St) Y 2x2x0.8 mm (0.03 inch) Line cross-section max. 2.5 mm2 (0.004 square inch) Approvals / marking Ex conformity in acc. with 94/9/EG: x II 2G Ex ia IIC T6/T4 Gb x II 1D Ex ia IIIC T95°C Da 1 red LED 1 green LED, Àashing approx. 15 mA 1 yellow LED (2nd line) -25 °C to +80 °C (-13 °F to +176 °F) IP 67 Diecast aluminium 0 to 95% no condensation EN 54 Part 5 Type examination certi¿cate: BVS 12 ATEX E121 IECEx conformity: IECEx BVS 12.0074 Ex conformity Russia in acc. with TP TC 012/2011: 1Ex ia IIC T6/T4 Gb 0Ex ia IIC T6/T4 Ga Ex ia IIIC T95°C Da G 207090 0786-CPD-20280 580 g (1.3 lbs) 130 x 133 mm (dia. x H) 5.1 x 5.2 inch (dia. x H) © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 23 Product Sheet | Detecon Industrial detectors UniVario High temperature heat detector FS, Ex WMX5000 FS 3GD 400°C (752 °F) Order no.: 907270 The WMX5000 FS 3GD high temperature heat detectors are ATEX-approved for category 3, gas and dust, and are suitable for use in Ex zones 2 and 22. They have been specially designed for operation in industrial environments with aggressive media and very high application temperatures in the monitoring area. For example in exhaust ducts, engine test stands or machine tools. In addition to stated temperature detection, rapid rises in temperature can also be registered by the rate-of-rise method, for early ¿re detection. Equipped for operation as a conventional detector. Extension to a detector with Loop AP protocol via the KMX5000 AP communication module. Product features • • • • • Robust stainless steel heat rod sensor. Freely con¿gurable response temperatures and classes in accordance with EN54-5, along with rate-of-rise and static responses. Con¿guration via DIP switches on the detector or SMX5000 service device. Service interface, history memory. Connection of remote indicator possible. For use in Ex zones 2 and 22, Atex category 3, Gas/Dust. Technical specifications Detection method Operating voltage Quiescent current approx. 0.25 mA Response temperatures Alarm current consumption Alarm indication Normal operation indication Current consumption Fault indication Fault indication Operating temperature IP rating (EN 60529) Enclosure material Relative humidity (IEC721-3-3) Speci¿cation according to P31.312.140en / 01.14 Weight Dimensions Parallel indicator KMX5000 AP communication module Silicone-free design 908499 905883 Not included in delivery Base UniVario MX5000 Single hole mounting ¿xture Single hole mounting tool Terminating resistor 1.8 K / 0.5 W 904701 800034 800388 675235 Connection / mounting PT1000 sensor A1, A2, B, C, D, E, F, G, indices S, R 0 °C to +400 °C (+32 °F to +752 °F) 7.6 V - 30 V DC Response classes Optional accessories approx. 15 mA 1 red LED 1 green LED, Àashing Connection cable standard detector 2-lead Additional fault line connection 2-lead External indication 2-lead Recommended cable JY (St) Y 2x2x0.8 mm (0.03 inch) Conductor cross-section max. 2.5 mm2 (0.004 square inch) Note The desired length of the sensor rod must be speci¿ed in millimetres at the time of placing the order. Alternatively, ¿xed standard rod lengths are available to choose from. The detector will be delivered with two Ex cable glands. These cable glands have to be used at the base. approx. 15 mA 1 yellow LED (2nd line) -20 °C to +80 °C (-4 °F to +176 °F) IP 67 Diecast aluminium 0 to 95% no condensation EN 54 Part 5 520 to 1600 g (1.2 to 3.5 lbs) 130 x 150 to 1500 mm (dia. x H) 5.1 x 5.9 to 59.1 inch (dia. x H) Approvals / marking Ex conformity in acc. with 94/9/EC: x II 3G Ex nA II T4 x II 3D Ex tD A22 IP65 T110°C Type examination certi¿cate: BVS 07 ATEX E 157 Ex conformity Russia in acc. with TP TC 012/2011: 2Ex nAc IIC T4 Ex tc IIIC T110°C IP65 G 207091 © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | 0786-CPD-20281 Chapter 6 - 24 Product Sheet | Detecon Industrial detectors UniVario High temperature heat detector FS, Ex WMX5000 FS 3GD 400 °C 200 mm (752 °F 7.9 inch) Order no.: 907281 With ¿xed rod length of 200 mm (7.9 inch). Otherwise like Order no.: 907270 Technical specifications Response temperatures Weight Dimensions 0 °C to +400 °C (+32 °F to +752 °F) 680 g (1.5 lbs) 130 x 260 mm (dia. x H) 5.1 x 10.2 inch (dia. x H) WMX5000 FS 3GD 400 °C 400 mm (752 °F 15.8 inch) Order no.: 907282 With ¿xed rod length of 400 mm (15.8 inch). Otherwise like Order no.: 907270 Technical specifications Response temperatures Weight Dimensions 0 °C to +400 °C (+32 °F to +752 °F) 840 g (1.9 lbs) 130 x 460 mm (dia. x H) 5.1 x 18.1 inch (dia. x H) WMX5000 FS 3GD 400 °C 600 mm (752 °F 23.6 inch) Order no.: 907283 With ¿xed rod length of 600 mm (23.6 inch). Otherwise like Order no.: 907270 Technical specifications Response temperatures Weight P31.312.140en / 01.14 Dimensions 0 °C to +400 °C (+32 °F to +752 °F) 1000 g (2.2 lbs) 130 x 660 mm (dia. x H) 5.1 x 26 inch (dia. x H) © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 25 Product Sheet | Detecon Industrial detectors UniVario High temperature heat detector FS, Ex WMX5000 FS Ex 400°C Order no.: 912108 The WMX5000 FS Ex high temperature heat detectors are ATEX- and IEC approved for category 2 gas and 1, 2 dust, and are suitable for use in Ex zones 1, 20 and 21. They have been specially designed for operation in industrial environments with aggressive media and very high application temperatures in the monitoring area. For example in exhaust ducts, engine test stands or machine tools. In addition to stated temperature detection, rapid rises in temperature can also be registered by the rate-of-rise method, for early ¿re detection. Equipped for operation as a conventional detector. Extension to a detector with Loop AP protocol via the KMX5000 AP Ex communication module. Product features • • • • • Robust stainless steel heat rod sensor. Freely con¿gurable response temperatures and classes in accordance with EN54-5, along with rate-of-rise and static responses. Con¿guration via DIP switches on the detector or SMX5000 service device. Service interface, history memory. Connection of remote indicator possible. For use in Ex zones 1, 20 and 21, Atex category 3 Gas/ 1, 2 Dust. Technical specifications Detection method Operating voltage PT1000 sensor A1, A2, B, C, D, E, F, G, indices S, R 0 °C to +400 °C (+32 °F to +752 °F) 7.6 V - 30 V DC Quiescent current approx. 2.8 mA Alarm current consumption approx. 15 mA Response classes Response temperatures Alarm indication Normal operation indication Current consumption Fault indication Fault indication Operating temperature IP rating (EN 60529) Enclosure material Relative humidity (IEC721-3-3) Speci¿cation according to P31.312.140en / 01.14 Weight Dimensions 1 red LED 1 green LED, Àashing approx. 15 mA 1 yellow LED (2nd line) -25 °C to +80 °C (-13 °F to +176 °F) IP 67 Diecast aluminium 0 to 95% no condensation EN 54 Part 5 520 to 1600 g (1.2 to 3.5 lbs) 130 x 150 to 1500 mm (dia. x H) 5.1 x 5.9 to 59.1 inch (dia. x H) Optional accessories Safety barrier IS conventional 9 V Safety barrier IS addressable 24 V KMX5000 AP Ex communication module Weather protection MX5000 complete Silicone-free design 904991 901324 912086 910134 Not included in delivery Base UniVario MX5000 Ex Single hole mounting ¿xture Single hole mounting tool Terminating resistor 1.8 K / 0.5 W 912082 800034 800388 675235 Connection / mounting Connection cable standard detector 2-lead Additional fault line connection 2-lead External indication 2-lead Recommended cable JY (St) Y 2x2x0.8 mm (0.03 inch) Conductor cross-section max. 2.5 mm2 (0.004 square inch) Note The desired length of the sensor rod must be speci¿ed in millimetres at the time of placing the order. Alternatively, ¿xed standard rod lengths are available to choose from. Approvals / marking Ex conformity in acc. with 94/9/EC: x II 2G Ex ia IIC T6/T4 Gb x II 1D Ex ia IIIC T95°C Da Type examination certi¿cate: BVS 12 ATEX E120 IECEx conformity: IECEx BVS 12.0073 Ex conformity Russia in acc. with TP TC 012/2011: 1Ex ia IIC T6/T4 Gb 0Ex ia IIC T6/T4 Ga Ex ia IIIC T95°C Da G 207091 © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | 0786-CPD-20281 Chapter 6 - 26 Product Sheet | Detecon Industrial detectors UniVario High temperature heat detector FS, Ex WMX5000 FS Ex 400 °C 200 mm (752 °F 7.9 inch) Order no.: 912110 With ¿xed rod length of 200 mm (7.9 inch). Otherwise like Order no.: 912108 Technical specifications Response temperatures Weight Dimensions 0 °C to +400 °C (+32 °F to +752 °F) 680 g (1.5 lbs) 130 x 260 mm (dia. x H) 5.1 x 10.2 inch (dia. x H) WMX5000 FS Ex 400 °C 400 mm (752 °F 15.8 inch) Order no.: 912111 With ¿xed rod length of 400 mm (15.8 inch). Otherwise like Order no.: 912108 Technical specifications Response temperatures Weight Dimensions 0 °C to +400 °C (+32 °F to +752 °F) 840 g (1.9 lbs) 130 x 460 mm (dia. x H) 5.1 x 18.1 inch (dia. x H) WMX5000 FS Ex 400 °C 600 mm (752 °F 23.6 inch) Order no.: 912112 With ¿xed rod length of 600 mm (23.6 inch). Otherwise like Order no.: 912108 Technical specifications Response temperatures Weight P31.312.140en / 01.14 Dimensions 0 °C to +400 °C (+32 °F to +752 °F) 1000 g (2.2 lbs) 130 x 660 mm (dia. x H) 5.1 x 26 inch (dia. x H) © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 27 Product Sheet | Detecon Industrial detectors UniVario High temperature heat detector FS Flex, Ex WMX5000 FS Flex 3GD 400°C (752 °F) Order no.: 907284 The WMX5000 FS 3GD high temperature heat detectors are ATEX-approved for category 3, gas and dust, and are suitable for use in Ex zones 2 and 22. They have been specially designed for operation in industrial environments with aggressive media and very high application temperatures in the monitoring area. For example in exhaust ducts, engine test stands or machine tools. In addition to stated temperature detection, rapid rises in temperature can also be registered by the rate-of-rise method, for early ¿re detection. Designed for operation as a conventional detector. Expansion to a detector with Loop AP protocol via the KMX5000 AP communications module. Product features Optional accessories • Robust Àexible stainless steel heat sensor. • Freely con¿gurable response temperatures and classes in accordance with EN54-5, along with rate-of-rise and static responses. Con¿guration via DIP switches on the detector or SMX5000 service device. Parallel indicator KMX5000 AP communication module Silicone-free design • Service interface, history memory. • Connection of remote indicator possible. • For use in Ex zones 2 and 22, Atex category 3, Gas/Dust. 908499 905883 Not included in delivery Base UniVario MX5000 Holder WMX FS, from 250 °C (482 °F) to 600 °C (1112 °F) Terminating resistor 1.8 K / 0.5 W 904701 894679 675235 Connection / mounting Technical specifications Detection method Operating voltage PT1000 sensor A1, A2, B, C, D, E, F, G, indices S, R 0 °C to +400 °C (+32 °F to +752 °F) 7.6 V - 30 V DC Quiescent current approx. 0.25 mA Response classes Response temperatures Alarm current consumption Alarm indication Normal operation indication Current consumption Fault indication Fault indication Operating temperature IP rating (EN 60529) P31.312.160en / 02.14 Enclosure material Relative humidity (IEC721-3-3) Speci¿cation according to Weight Dimensions approx. 15 mA 1 red LED 1 green LED, Àashing approx. 15 mA 1 yellow LED (2nd line) -20 °C to +80 °C (-4 °F to +176 °F) IP 67 Diecast aluminium 0 to 95% no condensation EN 54 Part 5 520 to 1600 g (1.2 to7.5 lbs) 130 x 2000 to 9000 mm (dia. x H) 5.1 x 78.7 x 354.3 inch (dia. x H) Connection cable standard detector 2-lead Additional fault line connection 2-lead External indication 2-lead Recommended cable JY (St) Y 2x2x0.8 mm (0.03 inch) Conductor cross-section max. 2.5 mm2 (0.004 square inch) Note The desired length of the Àexible sensor must be speci¿ed in metres at the time of placing the order. The sensor rod holder is designed for operation temperatures of up to 250 °C (482 °F). For higher operation temperatures, the WMX FS holder from 250 °C (482 °F) to 600 °C (1112 °F) Order no. 894679 is to be used. The detector will be delivered with two Ex cable glands. These cable glands have to be used at the base. Approvals / marking Ex conformity in acc. with 94/9/EC: x II 3G Ex nA II T4 x II 3D Ex tD A22 IP65 T110°C Type examination certi¿cate: BVS 07 ATEX E 157 Ex conformity Russia in acc. with TP TC 012/2011: 2Ex nAc IIC T4 Ex tc IIIC T110°C IP65 G 207091 © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | 0786-CPD-20281 Chapter 6 - 28 Product Sheet | Detecon Industrial detectors UniVario High temperature heat detector FS Flex, Ex WMX5000 FS Flex 3GD 400 °C 2 m (752 °F 79 inch) Order no.: 907285 Version with Àexible hose of 2 m length (79 inch). Otherwise like Order no.: 907284 Technical specifications Response temperatures Weight Dimensions 0 °C to +400 °C (+32 °F to +752 °F) 680 g (1.5 lbs) 130 x up to 2000 mm (dia. x H) 5.1 x up to 78.73 inch (dia. x H) WMX5000 FS Flex 3GD 400 °C 6 m (752 °F 236 inch) Order no.: 907286 Version with Àexible hose of 6 m length (236 inch). Otherwise like Order no.: 907284 Technical specifications Response temperatures Weight Dimensions 0 °C to +400 °C (+32 °F to +752 °F) 840 g (1.9 lbs) 130 x up to 6000 mm (dia. x H) 5.1 x up to 236.2 inch (dia. x H) WMX5000 FS Flex 3GD 400 °C 9 m (752 °F 354 inch) Order no.: 907287 Version with Àexible hose of 9 m length (354 inch). Otherwise like Order no.: 907284 Technical specifications Response temperatures Weight P31.312.160en / 02.14 Dimensions 0 °C to +400 °C (+32 °F to +752 °F) 1000 g (2.2 lbs) 130 x up to 9000 mm (dia. x H) 5.1 x up to 354.3 inch (dia. x H) WMX5000 FS Flex 3GD 400 °C (752 °F) CN Order no.: 909387 Approvals / marking Version China Otherwise like Order no.: 907284 © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 29 Product Sheet | Detecon Industrial detectors UniVario High temperature heat detector FS Flex, Ex WMX5000 FS Flex Ex 400°C Order no.: 912113 The WMX5000 FS Ex high temperature heat detectors are ATEX and IEC approved for category 2 gas and 1, 2 dust, and are suitable for use in Ex zones 1, 20 and 21. They have been specially designed for operation in industrial environments with aggressive media and very high application temperatures in the monitoring area. For example in exhaust ducts, engine test stands or machine tools. In addition to stated temperature detection, rapid rises in temperature can also be registered by the rate-of-rise method, for early ¿re detection. Designed for operation as a conventional detector. Expansion to a detector with Loop AP protocol via the KMX5000 AP Ex communications module. Optional accessories Product features Robust Àexible stainless steel heat sensor. • Freely con¿gurable response temperatures and classes in accordance with EN54-5, along with rate-of-rise and static responses. Con¿guration via DIP switches on the detector or SMX5000 service device. • Service interface, history memory. Not included in delivery • For use in Ex zones 1, 20 and 21, Atex category 2, Gas/1,2 Dust. Base UniVario MX5000 Ex Holder WMX FS, from 250 °C (482 °F) to 600 °C (1112 °F) Terminating resistor 1.8 K / 0.5 W Technical specifications Detection method Operating voltage PT1000 sensor A1, A2, B, C, D, E, F, G, indices S, R 0 °C to +400 °C (+32 °F to +752 °F) 7.6 V - 28 V DC Quiescent current approx. 2.8 mA Alarm current consumption approx. 15 mA Response classes Response temperatures Alarm indication Normal operation indication Current consumption Fault indication Fault indication Operating temperature IP rating (EN 60529) Enclosure material Relative humidity (IEC721-3-3) Speci¿cation according to Weight P31.312.160en / 02.14 Safety barrier IS conventional 9 V Safety barrier IS addressable 24 V KMX5000 AP Ex communication module Weather protection MX5000 complete Silicone-free design • Dimensions 1 red LED 1 green LED, Àashing approx. 15 mA 1 yellow LED (2nd line) -25 °C to +80 °C (-13 °F to +176 °F) IP 67 Diecast aluminium 0 to 95% No condensation EN 54 Part 5 520 to 1600 g (1.2 to7.5 lbs) 130 x 2000 to 9000 mm (dia. x H) 5.1 x 78.7 x 354.3 inch (dia. x H) 904991 901324 912086 910134 912082 894679 675235 Connection / mounting Connection cable standard detector 2-lead Additional fault line connection 2-lead External indication 2-lead Recommended cable JY (St) Y 2x2x0.8 mm (0.03 inch) Conductor cross-section max. 2.5 mm2 (0.004 square inch) Note The desired length of the Àexible sensor must be speci¿ed in metres at the time of placing the order. The sensor rod holder is designed for operation temperatures of up to 250 °C (482 °F). For higher operation temperatures, the WMX FS holder from 250 °C (482 °F) to 600 °C (1112 °F) Order no. 894679 is to be used. Approvals / marking Ex conformity in acc. with 94/9/EG: x II 2G Ex ia IIC T6/T4 Gb x II 1D Ex ia IIIC T95°C Da Type examination certi¿cate: BVS 12 ATEX E120 IECEx conformity: IECEx BVS 12.0073 Ex conformity Russia in acc. with TP TC 012/2011: 1Ex ia IIC T6/T4 Gb 0Ex ia IIC T6/T4 Ga Ex ia IIIC T95°C Da G 207091 © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | 0786-CPD-20281 Chapter 6 - 30 Product Sheet | Detecon Industrial detectors UniVario High temperature heat detector FS Flex, Ex WMX5000 FS Flex 3GD 400 °C 2 m (752 °F 79 inch) Order no.: 912114 Version with Àexible hose of 2 m length (79 inch). Otherwise like Order no.: 912113 Technical specifications Response temperatures Weight Dimensions 0 °C to +400 °C (+32 °F to +752 °F) 680 g (1.5 lbs) 130 x up to 2000 mm (dia. x H) 5.1 x up to 78.73 inch (dia. x H) WMX5000 FS Flex 3GD 400 °C 6 m (752 °F 236 inch) Order no.: 912115 Version with Àexible hose of 6 m length (236 inch). Otherwise like Order no.: 912113 Technical specifications Response temperatures Weight Dimensions 0 °C to +400 °C (+32 °F to +752 °F) 840 g (1.9 lbs) 130 x up to 6000 mm (dia. x H) 5.1 x up to 236.2 inch (dia. x H) WMX5000 FS Flex 400 °C 9 m (752 °F 354 inch) Order no.: 912116 Version with Àexible hose of 9 m length (354 inch). Otherwise like Order no.: 912113 Technical specifications Response temperatures Weight P31.312.160en / 02.14 Dimensions 0 °C to +400 °C (+32 °F to +752 °F) 1000 g (2.2 lbs) 130 x up to 9000 mm (dia. x H) 5.1 x up to 354.3 inch (dia. x H) © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 31 Product Sheet | Detecon Industrial detectors UniVario Detector accessories KMX5000 AP communication module Order no.: 905883 Communication module for the operation of UniVario detectors on ¿re alarm panels with Loop AP protocol. By simply plugging the module into the detector, a conventional detector is turned into an analogue addressable detector. The detector address is set via a DIP switch. Power supply and communications are connected via the ring bus; no additional power supply is required. The KMX5000 AP communication module is designed for integration into UniVario series detectors and must not be used in hazard areas. Product features Included in delivery • Communication module for constant signalling of operating condition, alarms and faults via Loop AP protocol. 1 KMX5000 AP communication module Pan-head screw and Spacer • Ring bus connection, no additional power supply. Connection / mounting • Integration in UniVario series detectors. Plug-in module in UniVario series detectors Technical specifications Connection 10 spring contacts (module/detector) Operating voltage 17 V - 28 V DC Operating current approx. 0,3 mA Communication protocol Addressing Operating temperature Relative humidity (IEC721-3-3) Loop AP 8 position DIP switch -20 °C to +80 °C (-4 °F to +176 °F) 5 to 85% no condensation Speci¿cation according to Weight Dimensions EN 54 Part 18 15 g (0.03 lbs) 54 x 28 x 19.5 mm (LxWxH) 2.1 x 1.1 x 0.8 inch (LxWxH) Approvals / marking 0786-CPD-20315 P31.312.810 - 1en / 01.14 G 207032 © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 32 Product Sheet | Detecon Industrial detectors UniVario Detector accessories KMX5000 AP Ex communication module Order no.: 912086 Communication module for the operation of UniVario detectors on ¿re alarm panels with Loop AP protocol. By simply plugging the module into the detector, a conventional detector is turned into an analogue addressable detector. The detector address is set via a DIP switch. Power supply and communications are connected via the ring bus; no additional power supply is required. The KMX5000 AP Ex communication module is designed for integration into UniVario series detectors and may be used in hazard areas. Product features Included in delivery • Communication module for constant signalling of operating condition, alarms and faults via Loop AP protocol. 1 KMX5000 AP Ex communication module Pan-head screw and Spacer • Ring bus connection, no additional power supply. Connection / mounting • Integration in UniVario Ex series detectors. Plug-in module in UniVario Ex series detectors Technical specifications Connection 10 spring contacts (module/detector) Operating voltage 14 V - 22 V DC Operating current approx. 0,3 mA Communication protocol Loop AP Addressing 8 position DIP switch -20 °C to +80 °C (-4 °F to +176 °F) 5 to 85% no condensation Operating temperature Relative humidity (IEC721-3-3) Speci¿cation according to Weight Dimensions EN 54 Part 18 15 g (0.03 lbs) 54 x 28 x 19.5 mm (LxWxH) 2.1 x 1.1 x 0.8 inch (LxWxH) Approvals / marking Ex conformity Russia in acc. with TP TC 012/2011: 1Ex ib IIC T5/T4 Gb applied for P31.312.810 - 1en / 01.14 applied for © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 33 Product Sheet | Detecon Industrial detectors UniVario Detector accessories Base MX5000 Order no.: 904701 Retaining base for all UniVario industrial ¿re detectors. Contains cable entries, EMC and environmental seals, connecting terminals and space for the optional relay module KMX5000 RK. Enables replacement of a detector without any terminal work. Not included in delivery End of line resistor 1.8 K / 0.5 W 675235 Spare parts Seal 127 x 2.9 / 1.6 mm Gland M 16 x 1.5 Ms Sealing cord 8 mm Vitron 0.036 m Technical specifications Material Aluminium Relative humidity Conductor cross-section max. 100 % 904752 901861 800605 Approvals / marking max. 2.5 mm2 (0.004 square inch) Colour red -40 °C to +100 °C (-40 °F to +212 °F) 310 g (0.7 lbs) Ambient temperature Weight Base MX5000 SF Order no.: 914235 Silicon free base. Otherwise like Order no. 904701 Base MX5000 3M16 Order no.: 907011 Retaining base for all UniVario industrial ¿re detectors. Contains cable entries, EMC and environmental seals, connecting terminals and space for the optional relay module KMX5000 RK. The third cable gland allows the interface connection with detector remote indicators or similar devices. Not included in delivery End of line resistor 1.8 K / 0.5 W 675235 Spare parts Seal 127 x 2.9 / 1.6 mm Gland M 16 x 1.5 Ms Sealing cord 8 mm Vitron 0.036 m Technical specifications P31.312.810 - 1en / 01.14 Material Aluminium Relative humidity Conductor cross-section Colour Ambient temperature Weight max. 100 % max. 2.5 mm (0.004 square inch) 2 Approvals / marking red -40 °C to +100 °C (-40 °F to +212 °F) 350 g (0.8 lbs) © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 34 904752 901861 800605 Product Sheet | Detecon Industrial detectors UniVario Detector accessories Base MX5000 LCD Order no.: 906127 Base for displaying status and signal messages from industrial ¿re alarms of the UniVario series. The LCD display gives information about sensor temperature, alarms or other operating states, depending on the detector type. Includes cable entries, EMC and environmental seals and connecting terminals. Enables replacement of a detector without any terminal work. The LCD base must not be used in hazard areas. Not included in delivery End of line resistor 1.8 K / 0.5 W Spare parts Technical specifications Operating voltage By means of the detector Operating current 0.3 mA Material Aluminium Relative humidity Conductor cross-section 675235 max. 100 % Seal 127 x 2.9 / 1.6 mm Gland M 16 x 1.5 Ms Sealing cord 8 mm Vitron 0.036 m 904752 901861 800605 Approvals / marking max. 2.5 mm2 (0.004 square inch) Colour red -20 °C to +70 °C (-4 °F to +158 °F) 350 g (0.8 lbs) Ambient temperature Weight Base MX5000-I Order no.: 912493 Detector base for installation of the UniVario industrial ¿re detectors in the LoopAP ringbus. Contains cable inlets, EMC and environmental sealing as well as terminals. Not suitable for use in explosion-prone areas. The installed dual isolator increases the operational safety of the LoopAP ringbus in the event of a short-circuit. The third cable screw connection is available for connecting detector mimic panels or similar devices. Spare parts Seal 127 x 2.9 / 1.6 mm Gland M 16 x 1.5 Ms Ex Sealing cord 8 mm Vitron 0.036 m Technical specifications Material Aluminium P31.312.810 - 1en / 01.14 Relative humidity Conductor cross-section Colour Ambient temperature Weight max. 100 % max. 2.5 mm (0.004 square inch) 2 red -20 °C to +80 °C (-4 °F to +176 °F) 530 g (1.2 lbs) © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 35 904752 904652 800605 Product Sheet | Detecon Industrial detectors UniVario Detector accessories Base MX5000 Ex Order no.: 912082 Detector base for installation of the UniVario industrial ¿re detectors of the Ex series. Contains cable inlets, EMC and environmental sealing as well as terminals. In this way, detectors can be replaced without requiring connecting work. Not included in delivery End of line resistor 1.8 K / 0.5 W 675235 Spare parts Seal 127 x 2.9 / 1.6 mm Gland M 16 x 1.5 Ms Ex Sealing cord 8 mm Vitron 0.036 m Technical specifications Material 904752 904652 800605 Aluminium Relative humidity Conductor cross-section max. 100 % max. 2.5 mm2 (0.004 square inch) Colour Ambient temperature Weight red -40 °C to +100 °C (-40 °F to +212 °F) 530 g (1.2 lbs) Bracket MX5000 Approvals / marking Ex conformity Russia in acc. with TP TC 012/2011: 1Ex ib IIC T5/T4 Gb Order no.: 904757 Mounting bracket for UniVario MX5000 base. Included in delivery 1 bracket UniVario MX5000 2 x screws M8, hex socket size 5 mm (0.2 inch). Not included in delivery Mounting screws for wall/ceiling-mounted installation. Technical specifications Material Bracket retention P31.312.810 - 1en / 01.14 Weight Spare parts Stainless steel, 2 mm (0.08 inch) thick Plastic (POM), black Screw M 8 904355 110 g (0.2 lbs) Bracket MX5000 SF Order no.: 914234 Silicon free bracket. Otherwise like Order no. 904757 © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 36 Product Sheet | Detecon Industrial detectors UniVario Detector accessories Isolator ISX 284 3GD Order no.: 915864 Isolator XP and DIS for the separation of individual line sections in the event of short circuits in ring bus operation with approval for ATEX category 3 gas and dust. Are suitable for use in Ex zones 2 and 22. Approvals / marking Technical specifications Material Aluminium Fault indication inside IP rating (EN60529) Colour Ambient temperature Weight x II 2G Ex d IIB T6 Gb x II 2D Ex tb IIIC T80°C Db Yellow LED IP 66 EC type approval certi¿cate: grey -20 °C to +60 °C (-4 °F to +140 °F) 1.2 kg (2.6 lbs) 90 mm (dia.) 3.5 inch (dia.) P31.312.810 - 1en / 01.14 Dimensions Ex conformity in acc. with 94/9/EG: © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 37 BVS 11 ATEX E114 Product Sheet | Detecon Industrial detectors UniVario Detector accessories Relay module KMX5000 RK Order no.: 906361 Communication module for the operation of UniVario detectors, independent of any ¿re detection system. Dry contacts for alarm and fault signalling allow the detectors to be used as stand-alone units, in any ¿re and hazard detection system or in building management and control systems. The KMX5000 RK communication module is designed to be integrated into the UniVario detector base MX5000 and must not be used in hazard areas. Product features Included in delivery • • Relay module KMX5000 RK Jumper Installation material Dry changeover contacts for alarm and fault signalling. Integration into MX5000 detector base. Technical specifications Connection Operating voltage Quiescent current Current consumption with alarm relay active Current consumption with alarm relay and fault relay active Voltage load, contacts Current load, contacts Fault indication Operating temperature Relative humidity (IEC721-3-3) 6-conductor ribbon cable 24 V (14 V - 29 V) DC Dimensions Conductor cross-section approx. 7 mA min. 0.5 mm2 (0.0008 square inch) Max. 2.5 mm2 (0.004 square inch) approx. 20 mA approx. 30 mA Max. 60 V DC, 25 V AC max. 1 A 1 yellow LED (2nd line) -20 °C to +80 °C (-4 °F to +176 °F) 5 to 85% no condensation Speci¿cation according to Weight Connection / mounting EN 54 Part 18 50 g (0.1 lbs) 64 x 24 x 57 mm (LxWxH) 2.5 x 0.9 x 2.2 inch (LxWxH) Approvals / marking 0786-CPD-20314 P31.312.810 - 1en / 01.14 G 208058 © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 38 Product Sheet | Detecon Industrial detectors UniVario Detector accessories Console MX5000 Flame detector Order no.: 904758 Console for the installation of UniVario Àame detectors outside of monitored areas, e.g. air ducts, machine tools, containers or silos. Easy access to the detector. Bayonet socket for reliable, vibration-proof hold. Antistatic material for use in hazard areas up to zones 1 and 21. Included in delivery Technical specifications Material Dimensions Colour Ambient temperature Weight PA6 99/0701 EC 138 x 15 mm (WxH) 6.6 x 0.6 inch (WxH) Black -20 °C to +100 °C (-4 °F to +212 °F) 145 g (0.3 lbs) Console MX5000 Heat detector Mount with Àat sealing and springs Screw M5 Self-tapping screw Blind rivets O-ring Installation drawing 906148 904341 765233 885078 904759 906970 Order no.: 906969 Console for the installation of UniVario heat detectors on e.g. air ducts, dryers or machine tools. Easy access to the detector. Bayonet socket for reliable, vibration-proof hold. Antistatic material for use in hazard areas up to zones 1 and 21. Included in delivery Technical specifications Material Dimensions Colour P31.312.810 - 1en / 01.14 Ambient temperature Weight PA6 99/07001 EC 138 x 16.2 mm (WxH) 5.4 x 0.6 inch (WxH) Black -20 °C to +100 °C (-4 °F to +212 °F) 145 g (0.3 lbs) Console with Àat sealing and springs Screw M5 Self-tapping screw Blind rivets O-ring Installation drawing © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 39 906148 904341 765233 885078 904759 906970 Product Sheet | Detecon Industrial detectors UniVario Detector accessories Weather protection MX5000 complete Order no.: 910134 Additional equipment – weather protection for Àame detectors of the Uni Vario series for use in case of increased solar radiation or exposure to harsh weather conditions. Connection / mounting Fasten the weather protection to the detector. Technical specifications Colour Stainless steel, 0.5 mm (0.02 inch) thick 140 x 110 x 220 mm (BxHxL) 5.5 x 4.3 x 8.7 inch (BxHxL) internally black Weight 300 g (0.67 lbs) Material P31.312.810 - 1en / 01.14 Dimensions © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 40 Product Sheet | Detecon Industrial detectors UniVario Test equipment Service device SMX5000 Order no.: 906136 The service device is for the simpli¿ed con¿guration, diagnostics and function testing of the UniVario detectors, and for indicating events from the history memory. The SMX5000 can be used on UniVario detectors with software version V01 Exx or higher. An RS-232 interface can be used to transmit data from the history memory to the UniVario View software. Product features Included in delivery • • • 1 service device SMX5000 1 connection cable, 30-pin 2 1.5 V batteries, type AA (LR6) Display with 3 rows of 12 characters each. Simple operation with clear menu structure. Operation and fault indication. Accessories Technical specifications LCD display Operating current (depends on the detector type) Operation time (depends on the detector and battery types) Batteries required IP rating 3 rows of 12 characters each approx. 80 mA at 3 V (with background lighting) approx. 25 mA at 3 V (without background lighting) approx. 5 mA at 3 V (in detector mode) approx. 25 hrs (with background lighting) approx. 80 hrs (without background lighting) approx. 400 hrs (in detector mode) 2 x 1.5 V Mignon, type AA (LR6) Battery 1.5 V Mignon, type AA (LR6) Connection cable, 30-pin Not included in delivery UniVario View software IP 20 Enclosure material Operating temperature Relative humidity (IEC721-3-3) Speci¿cation according to Weight Dimensions ABS plastic, RAL 7038 grey 0 °C to +50 °C (-32 °F to +122 °F) 5 to 85% no condensation EN 55022/CISPR22 CL. B, EN 55024, EN 61000-6-3, EN 61000-4-2, EN 61000-4-3, 26 g (0.1 lbs) 165 x 92 x 30 mm (LxWxH) 6.5 x 3.6 x 1.2 inch (LxWxH) P31.312.911en / 02.13 Approvals / marking © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 41 906751 906198 Product Sheet | Detecon Industrial detectors IR flame detector FMX3511 Order no.: 801618 Double infrared Àame detector FMX3511 for the detection of open Àames. Optic test monitors the functionality of the detector. Designed for use in raugh industrial environments. Equipped for operation as a conventional detector. Product features Not included in delivery • Highly reliable against false alarms, e.g. from hot surfaces. • A microcontroller monitors the functionality. Faults can be indicated on the detector or on a separate line. • Connection of remote indicator possible. Mounting device bracket with insulation Mounting device console 125x80Ø60 End of line-resistor 1.8 K / 0.5 W Sun screen Parallel indicator LMX5000 Plug for the pollution test • Single optic test. 801284 801280 675235 801277 908499 801079 Connection / mounting Connection cable standard detector 2-lead Recommended cable LiYCY 5x0.5 mm2 (0.0008 square inch) Cable gland M16x1.5, Brass nickel-plated, EMV Technical specifications Detection method Sensitivity class Viewing angle 3 7.6 V - 15 V DC Quiescent current approx. 3 mA Alarm indication Fault indication 1 LED yellow Operating temperature IP rating (EN 60529) Enclosure material Relative humidity (IEC721-3-3) Weight Dimensions 0786-CPD-20312 1 LED red approx. 7 mA Electrostatic shielding G 296016 approx. 18 mA Fault indication current Number of detectors per line Approvals / marking 60 ° Operating voltage Alarm current P31.312.330 - 3en / 02.13 2 IR Sensoren max. 4 Required -25 °C to +80 °C (-13 °F to +176 °F) IP 65 Diecast aluminium, RAL5009-blue max. 100% at + 35 °C (+95 °F) 600 g (1.3 lbs) 127 x 125 x 70 mm (BxHxT) 5 x 4.9 x 2.8 inch (BxHxT) © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 42 Product Sheet | Detecon Industrial detectors IR flame detector FMX3511 SF Order no.: 801619 Silicone-free Àame detector FMX3511 0.2 sec Order no.: 902532 Flame detectors with fast response within range of milsecounds are used for object monitoring (e.g. tooling machine). Technical specifications Criterion of detection FMX3511 0.2 sec SF Change of intensity Order no.: 902767 P31.312.330 - 3en / 02.13 Silicone-free Àame detector © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 43 Product Sheet | Detecon Industrial detectors IR flame detector FMX3511 BG Order no.: 891319 Double infrared Àame detector FMX3511 for the detection of open Àames. Optic test monitors the functionality of the detector. Designed for use in raugh industrial environments. Equipped for operation as a conventional detector. Product features Not included in delivery • Highly reliable against false alarms, e.g. from hot surfaces. • A microcontroller monitors the functionality. Faults can be indicated on the detector or on a separate line. End of line-resistor 1.8 K / 0.5 W Sun sreen Parallel indicator LMX5000 Plug for the pollution test • Connection of remote indicator possible. • Single optic test. Connection /mounting Connection cable standard detector 2-lead Recommended cable LiYCY 5x0.5 mm2 (0.0008 square inch) Cable gland M16x1.5, brass nickel-plated, EMV Technical specifications Detection method Sensitivity class Viewing angle Operating voltage Quiescent current Alarm current Alarm indication 3 Enclosure material Relative humidity (IEC721-3-3) Weight Dimensions 0786-CPD-20312 approx. 3 mA approx. 18 mA 1 LED red 1 LED yellow IP rating (EN 60529) G 296016 7.6 V - 15 V DC Fault indication Operating temperature Approvals / marking 60 ° approx. 7 mA Electrostatic shielding P31.312.330 - 4en / 02.13 2 IR Sensoren Fault indication current Number of detectors per line 675235 801277 908499 801079 max. 4 Required -25 °C to +80 °C (-13 °F to +176 °F) IP 65 Diecast aluminium, RAL5009-blue max. 100% at + 35 °C (+95 °F) 750 g (1.7 lbs) 127 x 155 x 92 mm (BxHxT) 5 x 6.1 x 3.6 inch (BxHxT) © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 44 Product Sheet | Detecon Industrial detectors IR flame detector FMX3511 BG SF Order no.: 800029 Silicone-free Àame detector FMX3511 BG 0.2 sec Order no.: 902533 Flame detectors with fast response within range of miliseconds are used for object monitoring (e.g. tooling machine). Technical specifications Criterion of detection FMX3511 BG 0.2 sec SF Change of intensity Order no.: 902768 P31.312.330 - 4en / 02.13 Silicone-free Àame detector © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 45 Product Sheet | Detecon Industrial detectors IR flame detector FMX3511 Console Order no.: 801609 Double infrared Àame detector FMX3511 for the detection of open Àames. Optic test monitors the functionality of the detector. Version Brachet mounting. Designed for use in rough industrial environments. Equipped for operation as a conventional detector. Product features Not included in delivery • Highly reliable against false alarms, e.g. from hot surfaces. • A microcontroller monitors the functionality. Faults can be indicated on the detector or on a separate line. • Connection of remote indicator possible. Mounting device bracket with insulation End of line-resistor 1.8 K / 0.5 W Sun sreen Parallel indicator LMX5000 Plug for the pollution test • Single optic test. Connection / mounting Connection cable standard detector 2-lead Recommended cable LiYCY 5x0.5 mm2 (0.0008 square inch) Cable gland M16x1.5, brass nickel-plated, EMV Technical specifications Detection method Sensitivity class Viewing angle 3 60 ° 7.6 V - 15 V DC Quiescent current approx. 3 mA Alarm indication Fault indication 1 LED yellow Operating temperature IP rating (EN 60529) Enclosure material Relative humidity (IEC721-3-3) Weight Dimensions G 296016 0786-CPD-20312 1 LED red approx. 7 mA Electrostatic shielding Approvals / marking approx. 18 mA Fault indication current Number of detectors per line P31.312.330 - 5en / 02.13 2 IR Sensoren Operating voltage Alarm current 801284 675235 801277 908499 801079 max. 4 Required -25 °C to +80 °C (-13 °F to +176 °F) IP 65 Diecast aluminium, RAL5009-blue max. 100% at + 35 °C (+95 °F) 950 g (2.1 lbs) 127 x 150 x 75 mm (BxHxT) 5 x 5.9 x 3 inch (BxHxT) © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 46 Product Sheet | Detecon Industrial detectors IR flame detector FMX3511 Console 0.2 sec Order no.: 902534 Flame detectors with fast response within range of miliseconds are used for object monitoring (e.g. tooling machine). Technical specifications Change of intensity P31.312.330 - 5en / 02.13 Criterion of detection © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 47 Product Sheet | Detecon Industrial detectors IR flame detector FMX3511 Console LSP Order no.: 801610 Double infrared Àame detector FMX3511 for the detection of open Àames. Optic test monitors the functionality of the detector. Version Brachet mounting and air Àushing function. Designed for use in rough industrial environments. Equipped for operation as a conventional detector. Product features Not included in delivery • Highly reliable against false alarms, e.g. from hot surfaces. • A microcontroller monitors the functionality. Faults can be indicated on the detector or on a separate line. • Connection of remote indicator possible. Mounting device bracket with insulation End of line-resistor 1.8 K / 0.5 W Sun sreen Parallel indicator LMX5000 Plug for the pollution test Compressed air supply • Single optic test. 801284 675235 801277 908499 801079 Connection / mounting Connection cable standard detector 2-lead Recommended cable LiYCY 5x0.5 mm2 (0.0008 square inch) Cable gland M16x1.5, brass nickel-plated, EMV Technical specifications Detection method Sensitivity class Viewing angle 3 7.6 V - 15 V DC Quiescent current approx. 3 mA Alarm indication Fault indication 1 LED yellow Operating temperature IP rating (EN 60529) Enclosure material Relative humidity (IEC721-3-3) Weight Dimensions Compressed air supply on site 0786-CPD-20312 1 LED red approx. 7 mA Electrostatic shielding G 296016 approx. 18 mA Fault indication current Number of detectors per line Approvals / marking 60 ° Operating voltage Alarm current P31.312.330 - 6en / 02.13 2 IR Sensoren max. 4 Required -25 °C to +80 °C (-13 °F to +176 °F) IP 65 Diecast aluminium, RAL5009-blue max. 100% at +35 °C (+95 °F) 970 g (2.1 lbs) 141 x 150 x 75 mm (BxHxT) 5.6 x 5.9 x 3 inch (BxHxT) Pressure range 0.8 - 1.5 bar © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 48 Product Sheet | Detecon Industrial detectors IR flame detector FMX3511 Console LSP 0.2 sec Order no.: 902535 Flame detectors with fast response within range of miliseconds are used for object monitoring (e.g. tooling machine). Technical specifications Change of intensity P31.312.330 - 6en / 02.13 Criterion of detection © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 49 Product Sheet | Detecon Industrial detectors IR flame detector Ex FMX3501 Ex Order no.: 903133 Infrared Àame detector FMX3501 Ex for the detection of open Àames. Optic test monitors the functionality of the detector. Designed for use in rough industrial environments. Equipped for operation as a conventional detector. Infrared Àame detector FMX3501 Ex are ATEX-approved for category 2 gas and 3 dust and are suitable for use in Ex zones 1 and 22. Intrinsically safe Àame detectors must be connected by correspondingly marked cables to explosion hazard barriers. Product features Not included in delivery • Highly reliable against false alarms, e.g. from hot surfaces. • A microcontroller monitors the functionality. Faults can be indicated on the detector or on a separate line. • Connection of remote indicator possible. Mounting device bracket with insulation Safety barrier IS conventional 9 V End of line-resistor 1.8 K / 0.5 W Sun screen Plug for the pollution test • Single optic test. Connection / mounting Connection cable standard detector 2-lead recommended cable LiYCY 5x0.5 mm2 (0.0008 square inch) Cable gland M16x1.5, Brass nickel-plated, EMV Technical specifications Detection method Sensitivity class Viewing angle 3 60 ° 7.6 V - 15 V DC Quiescent current approx. 3 mA Alarm indication approx. 18 mA 1 LED red Fault indication current approx. 7 mA Fault indication 1 LED yellow Number of detectors per line Electrostatic shielding Operating temperatur IP rating (EN 60529) Enclosure material Relative humidity (IEC721-3-3) Weight P31.312.340 - 2en / 01.14 2 IR Sensoren Operating voltage Alarm current Dimensions 801284 904991 675235 801277 801079 Approvals / marking Ex conformity in acc. with 94/9/EG: x II 2G 3G Ex ib IIC T6/T4 Type examination certi¿cate: DMT 02 ATEX E224 Ex conformity Russia in acc. with TP TC 012/2011: 1Ex ib IIC T6/T4 Gb G 296016 0786-CPD-20312 max. 4 Required -25 °C to +80 °C (-4 °F to +176 °F) IP 65 Diecast aluminium, RAL5009-blue max. 100% at +35 °C (+95 °F) 600 g (1.3 lbs) 127 x 125 x 70 mm (BxHxT) 3.9 x 2 inch (dia. x H) © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 50 Product Sheet | Detecon Industrial detectors IR flame detector Ex FMX3501 Ex SF Order no.: 903134 Silicone-free Àame detector FMX3501 Ex 0.2 sec Order no.: 903135 Flame detectors with fast response within range of miliseconds are used for object monitoring (e.g. tooling machine). Technical specifications Criterion of detection Change of intensity FMX3501 Ex 0.2 sec SF Order no.: 903136 Silicone-free Àame detector FMX3501 Ex T Order no.: 903137 Flame detector with non-latching alarm FMX3501 Ex T SF Order no.: 903138 Silicone-free Àame detector FMX3501 Ex T 0.2 sec Order no.: 903139 Flame detectors with fast response within range of miliseconds are used for object monitoring (e.g. tooling machine). P31.312.340 - 2en / 01.14 Technical specifications Criterion of detection FMX3501 Ex T 0.2 sec SF change of intensity Order no.: 903140 Silicone-free Àame detector © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 51 Product Sheet | Detecon Industrial detectors IR flame detector Ex FMX3501 Ex BG Order no.: 800000 Infrared Àame detector FMX3501 Ex for the detection of open Àames. Optic test monitors the functionality of the detector. Designed for use in rough industrial environments. Equipped for operation as a conventional detector. Infrared Àame detector FMX3501 Ex are ATEX-approved for category 2 gas and 3 dust and are suitable for use in Ex zones 1 and 22. Intrinsically safe Àame detectors must be connected by correspondingly marked cables to explosion hazard barriers. Product features Not included in delivery • Highly reliable against false alarms, e.g. from hot surfaces. • A microcontroller monitors the functionality. Faults can be indicated on the detector or on a separate line. Safety barrier IS conventional 9 V End of line-resistor 1.8 K / 0.5 W Sun screen Plug for the pollution test • Connection of remote indicator possible. • Single optic test. Connection / mounting Connection cable standard detector 2-lead Recommended cable LiYCY 5x0.5 mm2 (0.0008 square inch) Cable gland M16x1.5, brass nickel-plated, EMV Technical specifications Detection method Sensitivity class Viewing angle 3 60 ° 7.6 V - 15 V DC Quiescent current approx. 3 mA Alarm inducation 1 LED red approx. 7 mA Fault indication 1 LED yellow Electrostatic shielding Operating temperature IP rating (EN 60529) Enclosure material Relative humidity (IEC721-3-3) Weight Dimensions Approvals / marking Ex Conformity in acc. with 94/9/EG: x II 2G 3G Ex ib IIC T6/T4 Type examination certi¿cate: DMT 02 ATEX E224 Ex conformity Russia in acc. with TP TC 012/2011: 1Ex ib IIC T6/T4 Gb approx. 18 mA Fault indication current Number of detektors per line P31.312.340 - 3en / 02.14 2 IR Sensoren Operating voltage Alarm current 904991 675235 801277 801079 G 296016 0786-CPD-20312 max. 4 Required -25 °C to +80 °C (-4 °F to +176 °F) IP 65 Diecast aluminium, RAL5009-blue max. 100% at +35 °C (+95 °F) 750 g (1.6 lbs) 127 x 155 x 92 mm (BxHxT) 5 x 6.1 x 3.6 inch (BxHxT)) FMX3501 Ex BG CN Order no.: 907436 Version China Approvals / marking Otherwise like Order no 800000 © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 52 Product Sheet | Detecon Industrial detectors IR flame detector Ex FMX3501 Ex SF BG Order no.: 902769 Silicone-free Àame detector Otherwise like Order no 800000 FMX3501 Ex 0.2 sec BG Order no.: 902721 Flame detectors with fast response within range of miliseconds are used for object monitoring (e.g. tooling machine). Otherwise like Order no 800000 Technical specifications Criterion of detection Change of intensity FMX3501 Ex 0.2 sec SF BG Order no.: 902770 Silicone-free Àame detector Otherwise like Order no 800000 FMX3501 Ex T BG Order no.: 903141 Flame detector with non-latching alarm Otherwise like Order no 800000 FMX3501 Ex T SF BG Order no.: 903142 Silicone-free Àame detector Otherwise like Order no 800000 FMX3501 Ex T 0.2 sec BG Order no.: 903143 Flame detectors with fast response within range of miliseconds are used for object monitoring (e.g. tooling machine). Otherwise like Order no 800000 P31.312.340 - 3en / 02.14 Technical specifications Criterion of detection Change of intensity FMX3501 Ex T 0.2 sec SF BG Order no.: 903151 Silicone-free Àame detector Otherwise like Order no 800000 © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 53 Product Sheet | Detecon Industrial detectors UV flame detector Ex UMX3001 Ex Order.-no.: 903802 UV Àame detector for the detection of open Àames. Designed for use in rough industrial environments. Equipped for operation as a conventional detector. The UMX3001 Ex Àame detectors are ATEX-approved for category 2 gas and dust and are suitable for use in Ex zones 1 and 21. The UMX3001 Ex has a pressure resistant casing. Product fetures Not included in delivery • Wide ¿eld of view. End of line-resistor 1.8 K / 0.5 W • Fast Àame response. • High water and dust protection (IP67). Connection / mounting Technical specifications Detections method Viewing angle Number of detectors per line UV-Sensor 110 ° max. 4 Operating voltage 7.6 V - 13.2 V DC Quiescent cuttent approx. 1 mA Alarm current Alarm indication Electrostatic shielding Operating temperature IP rating (EN 60529) Enclosure material Relative humidity (IEC721-3-3) Weight approx. 20 mA Connection cable standard detector 2-lead Additional connection latching indication 1-lead Recommended cable LIYCY grey 5x0.5 mm2 (0.0008 square inch) Conductor cross-section max. 2.5 mm2 (0.004 square inch) Conducting cable diameter 5 mm to 9 mm (0.20 to 0.35 inch) Cable gland metal, EMV, Ex M16x1.5 Approvals / marking Ex conformity in acc. with 94/9/EG: x II 2G Ex d e IIC T6 x II 2D Ex tD A21 IP67 T80°C 1 LED red requiered -20 °C to +70 °C (-4 °F to +158 °F) IP 67 Diecast aluminium, silver grey Type examination certi¿cate: BVS 04 ATEX E 168 X max. 95% to +35 °C (95 °F) 3 kg (6.6 lbs) 88 x 190 mm (BxH) 3.5 x 7.5 inch (dia. x H) P31.312.320 - 2en / 02.13 Dimensions 675235 © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 54 Product Sheet | Detecon Industrial detectors Detector accessories Mounting device console 80x75 Ø54 (3.1x2.9 Ø 2.1 inch) Order no.: 902898 Mounting device to support gas emission detectors GMX1001CO I. Included in delivery 1 Mounting device console 80x75 Ø54 complete 2 Countersunk screw DIN923-M5x10 St 5 Self-taping screw DIN7981 C4.2x16 5 Blind rivet 3.2x16 alu 1 O-ring 60x3 Viton 2 Hex screw DIN933-M8x20-A2 2 Spring washer DIN127 B8-1.4310 Technical specifications Material Not included in delivery Plastic POM Colour black Weight 160 g (0.4 lbs) 112 x 112 mm (LxB) (4.4 x 4.4 inch (LxB) Adhesive LoctiteAVX 586, 50 ml 886226 Note Do not install the mounting device console in explosionhazard zone 1 P31.312.810 - 2en / 02.13 Dimensions 902896 835703 885080 885078 132587 772552 820707 © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 55 Product Sheet | Detecon Industrial detectors Detector accessories Mounting device console 125x80 Ø60 (4.9x3.1 Ø 2.3 inch) Order no.: 801280 Mounting device to support Àame detector FMX3511. Included in delivery 1 Mounting device console 125x80 Ø60 2 Countersunk screw DIN923-M5x10 St 5 Self-taping screw DIN7981 C4.2x16 5 Blind rivet 3.2x16 alu 1 O-ring 70x3 Viton 70°SH 2 Hex screw DIN933-M8x20-A2 2 Spring washer DIN127 B8-1.4310 Not included in delivery Technical specifications Material 801069 835703 885080 885078 800774 772552 820707 Adhesive LoctiteAVX 586, 50 ml 886226 Plastic PETP Colour black Weight 350 g (0.8 lbs) 120 x 150 mm (LxB) (4.7 x 5.9 inch (LxB) Dimensions Mounting device console 125x80 Ø60 (4.9x3.1 Ø 2.3 inch) LSP Note Do not install the mounting device console in explosionhazard zone 1. Order no.: 801281 Mounting device with air Àushing to support and preventive cleaning of the detector optics of Àame detectors FMX3511. Included in delivery 1 Mounting device console 125x80 Ø60 LSP 2 Countersunk screw DIN923-M5x10 St 5 Self-taping screw DIN7981 C4.2x16 5 Blind rivet 3.2x16 alu 1 O-ring 60x3 Viton 70°SH 2 Hex screw DIN933-M8x20-A2 2 Spring washer DIN127 B8-1.4310 Not included in delivery Technical specifications Medium Compressed air P31.312.810 - 2en / 02.13 Pressure range Connection thread Material Adhesive LoctiteAVX 586, 50 ml 886226 Air Àushing has to be supplied with compressed air on site. 0.8 - 1.5 bar G1/8“, DIN ISO228 Plastic PEPT Colour black Weight 370 g (0.8 lbs) 120 x 150 mm (LxB) (4.7 x 5.9 inch (LxB) Dimensions 801298 835703 885080 885078 800774 772552 820707 Note Do not install the mounting device console in explosionhazard zone 1. © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 56 Product Sheet | Detecon Industrial detectors Detector accessories Mounting device bracket with insulation Order no.: 801284 Mounting device to support gas emission detectors, Àame detectors, spark detectors and spark test light detectors. Included in delivery 1 Mounting device complete with 2 oval-head screw M8x12 for ¿xing the detector on the bracket. Not included in delivery Clamping screw for wall/ceiling mounting. Technical specifications Material bracket Material clamp Insulating Weight Oval-head screw M8x12-1.4301 Hex. nut DIN934-M8-A2/A4 Spring washer DIN127 B8-1.4310 160 g (0.4 lbs) 81.5 x 86 x 31 mm (LxBxH) (3.2 x 3.4 x1.2 inch (LxBxH) P31.312.810 - 2en / 02.13 Dimensions Spare parts Stainless steel, 2 mm (0.08 inch) thick Stainless steel, 1.5 mm (0.06 inch) thick Plastic POM © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 57 800596 820781 820707 Product Sheet | Detecon Industrial detectors Detector accessories Support disk mounting 90 °C (194 °F) Order no.: 891848 Quick installation device to support detections with single-hole. The installation is allowed up to a wall thickness of 8 mm (0.3 inch). Technical specifications Enclosure material: -mounting coupling -hex. nut -oval washer -tapered block Operating temperature stainless steel brass stainless steel Polyamid PA12, black to +90 °C (+194 °F) Weight Support disk mounting 250 °C (482 °F) 120 g (0.3 lbs) Order no.: 800034 Quick installation device to support detections with single-hole and ¿bre options. Technical specifications Enclosure material: -tapered block 250 °C (482 °F) Operating temperature Peck / Mod, black to +250 °C (+482 °F) Otherwise like Order no. 891848. Flushing air device Order no.: 907822 Quick installation device to support detections with single-hole and air Àushing. . Technical specifications Enclosure material: V2A and PA 12 -10 °C to +60 °C (-14 °F to +140 °F) 0.2 to 10 bar Operating temperature Operating pressure Weight 200 g (0.4 lbs) 55 x 48 mm (DxL) 2.2 x 1.9 inch (DxL) Dimensions Mounting tool mounting socket - F180 Order no.: 843474 Technical specifications P31.312.810 - 2en / 02.13 Enclosure material stainless spring band steel Weight © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | 90 g (0.2 lbs) Chapter 6 - 58 Product Sheet | Detecon Industrial detectors Flame detector accessories Sun screen FMX3511/FMX3501 Ex Order no.: 801277 Protection against skewness parasitic radiation (e.g. sunlight for outside applications) for the Àame detector FMX3511 and FMX3501 Ex. Connection / mounting Plug sun screen onto detector optic. Note After mounting the sunscreen can not be removed. Technical specifications Colour Stainless steel, 2.5 mm (0.09 inch) thick 62.5 x 53 mm (WxH) 2.5 x 2.1 inch (WxH) internally black Weight 90 g (0.2 lbs) Material Dimensions Cleaning kit optic Order no.: 916644 To clean the optic and reÀective surface by Àame detectors. Included in delivery P31.312.391en / 02.14 1 packaging unit (20 cleaning cloth and 10 cleaning sponge) © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 59 Product Sheet | Detecon Industrial detectors Gas emission detector GMX1001CO I Order no.: 900960 Multi sensor ¿re gas detector GMX1001CO I for the early detection of smoldering ¿res. Designed for use in rough industrial environments (e.g. silos, chip bunkers). The GMX1001CO I detects the burning characteristic substance carbon monoxide and temperature. False alarms are nearly impossible. Equipped for operation as a conventional detector. Product features Not included in delivery • A microcontroller monitors the functionality and values. • Multi sensor carbon monoxide and temperature. • Connection of remote indicator possible. Mounting device bracket with insulation Mounting device console 80x75 Ø54 End of line-resistor 1.8 K / 0,5 W Test device smoke generator RG2000 Parallel indicator LMX5000 Technical specifications Detection method Alarm threshold: - Carbon monoxide - Temperature - Rate of rise measurement CO (carbon monoxide) and temperature Operating voltage • 40 ppm > 60 °C (140 °F) dT > 3 °C/min. at T > 36 °C (96,8 °F) 7,6 V - 40 V DC Quiescent current approx. 0.15 mA Alarm current Alarm indication Electrostatic shielding Operating temperature IP rating (EN 60529) Enclosure material Relative humidity (IEC721-3-3) Weight Connection / mounting Connection cable standard detector 2-lead Conductor cross-section max. 2.5 mm2 (0.004 square inch) Fire detection cable with static shield 606061 LIYCY grey 5x0.5 mm2 (0.0008 square inch) Cable gland M16x1.5, Brass nickel-plated, EMV Spare parts Screwed mounting GMX1001COI complete Sensor GMX1002CO 1 LED red Required -20 °C to +50 °C (-4 °F to +122 °F) IP 65 Diecast aluminium, RAL5009-blue max. 15 to +90 % no condensation 480 g (1.1 lbs) 122 x 80 x 69 mm (BxHxT) 4.8 x 3.2 x 2.7 inch (BxHxT) Note Simple one man calibration. Approvals / marking G 204121 0786-CPD-20135 P31.312.610 - 1en / 02.13 Dimensions approx. 18 mA 801284 902898 675235 902671 908499 © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 60 902923 900968 Product Sheet | Detecon Industrial detectors Gas emission detector GMX1001CO 300ppm Order no.: 909139 Special detector for application in areas with emissions of carbon monoxide increased due to operating conditions. Approvals / marking Technical specifications • 300 ppm > 100 °C (212 °F) dT > 3 °C/min. at T > 80 °C (176 °F) P31.312.610 - 1en / 02.13 Response monoxide: - Carbon monoxide - Temperature - Differential measurement © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 61 Product Sheet | Detecon Industrial detectors Gas emission detector GMX1001CO I BG Order no.: 902891 Multi sensor ¿re gas detector GMX1001CO I BG for the early detection of smoldering ¿res. Designed for use in rough industrial environments (e.g. silos, chip bunkers). The GMX1001CO I detects the burning characteristic substance carbon monoxide and temperature. False alarms are nearly impossible. Designed for operation as a conventional detector. Product features Not included in delivery • A microcontroller monitors the functionality and values. • Multi sensor carbon monoxide and temperature. • Connection of remote indicator possible. Mounting device console 80x75 Ø54 End of line-resistor 1.8 K / 0.5 W Test device smoke generator RG2000 Parallel indicator LMX5000 Connection / mounting Technical specifications Detection method Alarm threshold: - Carbon monoxide - Temperature - Rate of rise measurement CO (carbon monoxide) and temperature Operating voltage • 40 ppm > 60 °C (140 °F) dT > 3 °C/min. at T > 36 °C (96,8 °F) 7.6 V - 40 V DC Quiescent current approx. 0.15 mA Alarm current Alarm indication Electrostatic shielding Operating temperature IP rating (EN 60529) Enclosure material Relative humidity (IEC721-3-3) Weight Connection cable standard detector 2-lead Conductor cross-section max. 2.5 mm2 (0.004 square inch) Fire detection cable with static shield 606061 LIYCY grey, 5x0.5 mm2 (0.0008 square inch) Cable gland M16x1.5, Brass nickel-plated, EMV Spare parts Screwed mounting GMX1001COI complete Sensor GMX1002CO approx. 18 mA 1 LED red Required -20 °C to +50 °C (-4 °F to +122 °F) IP 65 Diecast aluminium, RAL5009-blue max. 15 to +90 % no condensation 600 g (1.3 lbs) 122 x 106 x 88 mm (BxHxT) 4.8 x 4.2 x 3.5 inch (BxHxT) Note Simple one man calibration. Approvals / marking G 204121 0786-CPD-20135 P31.312.610 - 2en / 02.13 Dimensions 902898 675235 902671 908499 © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 62 902923 900968 Product Sheet | Detecon Industrial detectors Gas emission detector GMX1001CO 300ppm BG Order no.: 909161 Special detector for application in areas with emissions of carbon monoxide increased due to operating conditions. Approvals / marking Technical specifications • 300 ppm > 100 °C (212 °F) dT > 3 °C/min. at T > 80 °C (176 °F) P31.312.610 - 2en / 02.13 Response values: - Carbon monoxide - Temperature - Differential measurement © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 63 Product Sheet | Detecon Industrial detectors Gas emission detector GMX1001CO I Console Order no.: 902893 Multi sensor ¿re gas detector GMX1001CO I Console for the early detection of smoldering ¿res. Designed for use in rough industrial environments (e.g. silos, chip bunkers). Version bracket mount. The GMX1001CO I detects the burning characteristic substance carbon monoxide and temperature. False alarms are nearly impossible. Designed for operation as a conventional detector. Product features Not included in delivery • A microcontroller monitors the functionality and values. • Multi sensor carbon monoxide and temperature. • Connection of remote indicator possible. Mounting device bracket with insulation End of line-resistor 1.8 K / 0.5 W Test device smoke detector RG2000 Parallel indicator LMX5000 Connection / mounting Technical specifications Detection method Alarm threshold: - Carbon monoxid - Temperature - Rate of rise measurement CO (carbon monoxide) and temperature Operating voltage • 40 ppm > 60 °C (140 °F) dT > 3 °C/min. at T > 36 °C (96.8 °F) 7.6 V - 40 V DC Quiescent current approx. 0.15 mA Alarm current Alarm indication Electrostatic shielding Operating temperature IP rating (EN 60529) Enclosure material Relative humidity (IEC721-3-3) Weight approx. 18 mA 1 LED red Required -20 °C to +50 °C (-4 °F to +122 °F) IP 65 Diecast aluminium, RAL5009-blue max. 15 at +90 % no condensation 600 g (1.3 lbs) 122 x 112 x 75 mm (BxHxT) 4.8 x 4.4 x 3 inch (BxHxT) Connection cable standard detector 2-lead Conductor cross-section max. 2.5 mm2 (0.004 square inch) Fire detection cable with static shield 606061 LIYCY grey, 5x0.5 mm2 (0.0008 square inch) Cable gland M16x1.5, Brass nickel-plated, EMV Spare parts Screwed mounting GMX1001COI complete Sensor GMX1002CO Note Simple one man calibration. Approvals / marking P31.312.610 - 3en / 02.13 Dimensions 801284 675235 902671 908499 © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 64 902923 900968 Product Sheet | Detecon Industrial detectors Gas emission detector GMX1001CO 300ppm Console Order no.: 909162 Special detector for application in areas with emissons of carbon monoxide increased due to operating conditions. Approvals / marking Technical specifications • 300 ppm > 100 °C (212 °F) dT > 3 °C/min. at T > 80 °C (96.8 °F) P31.312.610 - 3en / 02.13 Response values: - Carbon monoxide - Temperature - Differential measurement © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 65 Product Sheet | Detecon Industrial detectors Gas emission detector Ex GMX1001CO Ex Dust Order no.: 905642 Multi sensor ¿re gas detector GMX1001CO Ex Dust for the early detection of smoldering ¿res. Designed for use in raugh industrial environments (e.g. silos, chip bunkers). The GMX1001CO I detects the burning characteristic substance carbon monoxide and temperature. False alarms are nearly impossible. Designed for operation as a conventional detector. The GMX1001CO Ex Dust gas detectors are ATEX-approved for category 1 and 2 dust and are suitable for use in Ex zone 20 and 21. Product features Not included in delivery • A microcontroller monitors the functionality and values. • Multi sensor carbon monoxide and temperature. • Connection of remote indicator possible. Mounting device bracket with insulation Mounting device console 80x75Ø54 End of line-resistor 1.8 K / 0.5 W Test device smoke generator RG2000 Parallel indicator LMX5000 Technical specifications Detection method Alarm threshold: - Carbon monoxide - Temperature - Rate of rise measurement Number of detectors per line CO (carbon monoxide) and temperature • 40 ppm > 60 °C (140 °F) dT > 3 °C/min. at T > 36 °C (96.8 °F) max. 32 Operating voltage 7.6 V - 40 V DC Quiescent current approx. 0.15 mA Alarm current Alarm indication Electrostatic shielding Operating temperature IP rating (EN 60529) Enclosure material Relative humidity (IEC721-3-3) Weight 1 LED red Required -20 °C to +50 °C (-4 °F to +122 °F) IP 65 Diecast aluminium, RAL5009-blue max. 15 at + 90 % no condensation 480 g (1.1 lbs) 122 x 80 x 69 mm (BxHxT) 4.8 x 3.2 x 2.7 inch (BxHxT) Connection / mounting Connection cable standard detector 2-lead Conductor cross-section max. 2.5 mm2 (0.004 square inch) Fire detection cable with static shield 606061 LIYCY grey, 5x0.5 mm2 (0.0008 square inch) Cable gland M16x1.5, Brass nickel-plated, EMV, Ex Spare parts Screwed GMX1001COI complete Sensor GMX1002CO 902923 900968 Hinweis Simple one man calibration Approvals Ex conformity in acc. with 94/9/EG: x II 1/2D Ex tD A20/21 IP65 T136°C x II 1D Ex tD A20 IP65 T136°C Type examination certi¿cate: BVS 05 ATEX E179 Approvals / marking G 204121 0786-CPD-20135 P31.312.620 - 1en / 02.13 Dimensions appro. 18 mA 801284 902898 675235 902671 908499 © Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 66