Transcript
Quick Installation Guide
Infortrend
R
SANWatch Management Software
1
Conceptual Basics: Direct-attached
via LAN/WAN SANWatch +
Data Host agent
Management Host agent
Application Server
Direct-attached Server
LAN/WAN
in-band
Remote station RAID
RAID
One-to-many, Centralized Management Storage Management Task Scheduler Performance monitoring Physical View Logical View ....
Portal: Collective View
Notification Manager
LAN
LAN/WAN
SANWatch Full mode
Management Host agent
RAID
SANWatch console c 2007 by Infortrend Technology, Inc. All rights reserved. * Any information provided herein is without warranties of any kind and is subject to change by Infortrend without prior notice. * Infortrend offers a 3-year limited warranty on subsystems and a 1-year warranty on battery backup units. * Infortrend and the Infortrend logo are registered trademarks of Infortrend Technology, Inc. * EonStor and SANWatch are registered trademarks of Infortrend Technology, Inc. * All other names, brands, products, or services are trademarks or registered trademarks of their respective owners.
AMERICAS Infortrend Corporation 2200 Zanker Road, Unit D, San Jose, CA. 95131, USA Tel:+1-408-988-5088 Fax:+1-408-988-6288
[email protected] http://esupport.infortrend.com http://www.infortrend.com/americas
ASIA PACIFIC Infortrend Technology, Inc. 8F, No. 102 Chung-Shan Rd., Sec. 3 Chung-Ho City, Taipei Hsien, Taiwan Tel:+886-2-2226-0126 Fax:+886-2-2226-0020
[email protected] [email protected] http://esupport.infortrend.com.tw http://www.infortrend.com
CHINA Infortrend Technology, Ltd. Room 1210, West Wing, Tower One, Junefield Plaza, No. 6 Xuanwumen Street, Xuanwu District, Beijing, China. 100052 Tel:+86-10-63106168 Fax:+86-10-63106188
[email protected] [email protected] http://esupport.infortrend.com.tw http://www.infortrend.com/china
JAPAN EUROPE (EMEA) Infortrend Japan, Inc. Infortrend Europe Ltd. 6F Okayasu Bldg., 1-7-14 Shibaura, 1 Cherrywood, Stag Oak Lane Minato-ku, Tokyo, 105-0023 Japan Chineham Business Park TEL:+81-3-5730-6551 Basingstoke, Hampshire FAX:+81-3-5730-6552 RG24 8WF, UK
[email protected] Tel:+44-1256-707-700
[email protected] Fax:+44-1256-707-889 http://esupport.infortrend.com.tw http://www.infortrend.com/japan
[email protected] [email protected] http://esupport.infortrend-europe.com http://www.infortrend.com/europe
SAN GERMANY Infortrend Deutschland GmbH Werner-Eckert-Str.8 81829 Munich Germany Tel: +49 (0)89 45 15 18 7 - 0 Fax: +49 (0)89 45 15 18 7 - 65
[email protected] [email protected] http://www.infortrend.com/germany
Management Host agent
Event notification
RAID Independent RAID (access via TCP/IP)
Data Host agent
SANWatch Connection Concerns:
Installation Options: 1. Under a Windows environment, locate and run the setup.exe program. 2. For Solaris and Linux platforms, please execute the associated “*.sh” batch files.
Installation Modes: Depending on your topological requirement, you can either select a Full mode or select the Custom mode to install an independent agent.
Installation Modes:
** On Linux, use the “modeprobe –v sg” command to start SCSI generic service to facilitate in-band connection. Windows Messaging (MAPI) for Windows 2003/XP if fax notification support is needed. TCP/IP with a valid IP assigned to each controller/subsystem. Consult your network administrator for configuration of network IPs. A public IP or the use of VPN will be necessary if you prefer a remote session with the arrays located within a private network. Some network security measures may prevent you from querying array statuses. For example, your Windows Firewall can disable the access from your Management Host agent to individual arrays. You can configure exceptional access in your firewall utility using exception rules to allow Java agent negotiation.
Custom Mode:
Below are the port numbers for use if you need to manually configure secure access:
Full mode: All SANWatch components
TCP/IP Port Assignments
58641
Port for receiving the “auto discovery” responses.
58699
Port for listening to the SANWatch Portal requests.
Software
Custom mode: Select component(s)
Data Host Agent (in-band)
58630
SSL port for connecting RAID.
58632
Non-SSL port for connecting RAID.
58632
Non-SSL port for a console to connect.
58641
Port for receiving the “auto discovery” responses.
58640
Port for listening to the “auto discovery” requests.
58630
VSS agent
Management Host Agent (TCP/IP) 58634
SSL port for a console to connect.
Port for listening to the Notification Manager requests.
58650
Port for listening to VSS requests.
MPIO agent
58635
2
Port for synchronizing Management Host Agent in a
58670
Port for listening to MPIO requests.
redundant SANWatch installation. UDP Port Assignments
Requirements
58640
RAID Management GUI:
? Computer must be Pentium or above PC compatible running
58641
- Windows 2003 R2 sp1 (32/64), Windows XP, Vista - RedHat AS 3.0, ES 4 (32/64), - SUSE Linux Enterprise 9 (64), Professional 9.1, SLES 10 (32/64) - Fedora Linux 3 (64), Fedora Linux 5 (32/64) - FreeBSD 5 - Solaris 8/9/10 Sparc
- Valid Ethernet link through TCP/IP
- Mac OS X 10.4.x
- A monitor capable of 16 bit color mode
Java Runtime Environment: - Java Runtime v1.6 comes with SANWatch rev.1.2.C. On Solaris and Linux platforms, make sure to update your previously-installed environment.
Data Service: (snapshot)
? The Data Service, Snapshot function is supported on Windows 2003, Solaris 10, and some Linux platforms.
1
6
Both should be enabled for all modules.
3 from previous page.
Installation:
Caution! Close other applications before installation to avoid incompatibility.
Proceed with one of the following to initiate the SANWatch installer program.
1. MS Windows:
1
Single click on the product CD’s Autorun screen. - or Locate and execute the ‘Setup.exe” installation program
2. Linux: Open the file manager and change the directory
4-4. Reset your computer to complete the installation.
to /mnt/cdrom. Locate and execute ./linux.sh to start the installer program.
2
3. Solaris:
5
Locate and execute the “unix.sh” batch file
An application server using the snapshot
in the File Manager window.
functions must be a direct- or SAN-attached server using either the Full mode or the Custom ->
Type “y” in the Run window to continue.
Remote console
Local console
Data Host agent installation.
NOTE: The Data Host agents installed will function as the intermediate RAID management agents
vi a
Data Host Agent
TC PI/ P
DAS/SAN server
4. Mac OS X 10.4 w/ Safari:
LAN/WAN
and also the flush agents
The installer batch will automatically install a Java Runtime.
enacted before automated
Enabling Root Access.
snapshots. 4-1. Log in using the Admin account. A remote SANWatch console is
Firmware
available by connecting the
RAID
4-2. Locate the GO menu from Mac OS’s finder menu.
server IP instead of RAID
Access the Utilities folder and
controller IP.
start the NetInfo Manager.
5
2
4 4-3. Click on the Lock icon on the lower left of the screen. 4-4. Locate the Security command menu from the top menu bar, and select.
4-5. Log in and log out to verify that it works.
Installer Program Options: 4-2. Read the statement carefully, and
4-1. Click Next on the welcome screen.
click Accept to proceed.
4-6. Select “Other” from the login screen and manually enter “root” as the user name and its password.
“Enable root user.” Enter administrator’s password.
You may now start installing SANWatch to your Mac machine.
4-7. Initiating the installer program. Simply locate and double-click on the “installshield.jar” installer file.
4-3. Select either the Full or Custom mode installation.
Custom Mode:
Full Mode:
5. Mac OS X 10.5 Leopard: Enabling Root Access. 5-1. Log in using the Admin account. 5-2. Open the Directory Utility from the GO ->
Select one or more components:
Utilities menu. SANWatch:
5-3. Unlock to make configuration changes.
Checked if this is where a SANWatch console is run.
5-4. Provide the Admin password.
Data Host
On a DAS/SAN server or
5-5. Execute the Enable Root User
agent:
a machine using snapshot functions over in-band
command from the Edit menu.
protocols.
5-6. Enter Root user password. 5-7. Log out and then log in using the root account. 5-8. Run the installshield.jar to begin
Magt. Host:
A Management center to
agent
collect info from multiple RAID arrays.
installation. Select Single or enter the IP addresses if you
To next page. 3
prefer to install SANWatch redundantly on two servers.
4