Transcript
Infrastructure components PROFINET Indu-Sol GmbH – Specialist for Industrial Networks
PROFINET cable Cat5 type B, flexible +FE Function The +FE PROFINET cable is a flexible data cable for transmission of analog and digital signals on cabling according to PROFINET standard in industrial environments. The double shield braiding ensures maximum shielding values.
Standards • EN 50288-2-2; EN 50173; ISO/IEC 11801 2. edition; IEC 61156-5; PROFInet Draft • EN 60332-1; UL 444 CMX/CMH
Applications • IEEE 802.3: Ethernet 10Base-T; Fast Ethernet 100Base-T; Gigabit Ethernet 1000Base-T • IEEE 802.5: ISDN; FDDI; ATM
Construction • Conductor: Cu AWG 22/7, tinned • Insulation: PE • Diameter: 1,54 ± 0,02 mm • Stranding: Quad • Inner jacket: Spezial PVC • Shielding total: Plastic laminted Aluminium foil • Inner screen: Copper, wire 0,10 • Outer screen: Copper, wire 0,10 Opt. coverage > 85% • Screen section: > 1,5 mm² • Carrying capacity: max. 10 A (outer screen): • Jacket: Spezial PVC • Colour: Green, RAL 6018 • Diameter: 7,0 ± 0,2 mm
Electrical data
PROFINET-Cable Cat5 Typ B, flexible +FE Shielding braid Outer jacket Shielding braid Shielding foil Inner jacket Insulation 7 conductors
Cross section PROFINET-Cable Cat5 Typ B, flexible +FE
• Loop resistance: • Insulation resistance: • Operating capacity: • Char. impedance at 1000 MHZ: • Test voltage: • Velocity of propagation: • Signal term: • Running time difference: • Screen attenuation: • Couling attenuation: • Transfer impedance:
Max. 120 Ohm/km according to VDE 0812 Min. 5 GOhm x km at +20°C Nom. 50nF/km 100 Ohm ± 5Ohm 700 V/DC ca. 0,67 c max. 510 ns/100m < 25ns/100m > 85 dB > 95 dB < 10 mOhm/m at 1 MHz < 10 mOhm/m at 10 MHz < 30 mOhm/m at 30 MHz
Mechanical and thermal data 120 N 10 x diameter during installation 5 x diameter fixed -30°C to +75°C 0°C to +50°C
Ordering details Art. No. +FE PROFINET cable flexible
Indu-Sol GmbH
•
Blumenstrasse 3 • 04626 Schmoelln • Phone: +49 (0) 34491 5818-0 • Fax: +49 (0) 34491 5818-99 •
[email protected]
114060003 •
www.indu-sol.com
Updated 05/2016
• Max. tractive force: • Bending radius: • Temperatur range: ○fixed: during installation: