Preview only show first 10 pages with watermark. For full document please download

Ingen Lysbildetittel

   EMBED


Share

Transcript

® Interactive Fire Alarm System ID: AutroSafe_intro_eng, 2002-05 Protecting life, environment and property... 1 Milestones in the development of Fire Alarm System by Autronica: 1959: The first fully transistorised Conventional Fire Alarm System in the world (BS-10) 1969: The first low voltage smoke detector (BJ-1) 1979: Autronica introduces the first Analogue Addressable Fire Alarm System (BS-3) 1989: Autronica launches the first Analogue Addressable Fire Alarm System with active handling of detector signals (DYFI) 1999: Autronica delivers the first self-verifying Fire Alarm System capable of controlling itself, interactive AutroSafe SelfVerify 2 Protecting life, environment and property... Traditional AnalogueAddressable centralized Fire Alarm System: Autronica FIRE MORE ALARMS PREWARNING FAULT SILENCE BUZZER POWER 4th floor KNUS GLASSET TRYKK HER PRESS HERE KNUS GLASSET TRYKK HER PRESS HERE BREAK GLASS BREAK GLASS FIRE Autronica KNUS GLASSET TRYKK HER PRESS HERE MORE ALARMS PREWARNING FAULT POWER SILENCE BUZZER BREAK GLASS 3rd floor FIRE Autronica MORE ALARMS PREWARNING FAULT SILENCE BUZZER POWER KNUS GLASSET TRYKK HER PRESS HERE KNUS GLASSET TRYKK HER PRESS HERE BREAK GLASS BREAK GLASS 2nd floor Autronica FIRE MORE ALARMS PREWARNING FAULT SILENCE BUZZER POWER KNUS GLASSET TRYKK HER PRESS HERE 1st floor BREAK GLASS Autronica FIRE MORE ALARMS PREWARNING FAULT SILENCE BUZZER POWER KNUS GLASSET TRYKK HER PRESS HERE KNUS GLASSET TRYKK HER PRESS HERE BREAK GLASS BREAK GLASS BRANN S O P R E T L F IC M A N Y D SLOKKEANLEGG AKTIVERT AVSTILL KLOKKER BRANNVENTILASJON AKTIVERT BRANNVESEN MOTTATT MELDING FLERE ALARMER TILBAKESTILL ALARMSTED UTKOBLET FORVARSEL Ground floor FEIL DELER AV ANLEGGET UTKOBLET BS 100 NETT Basement Autronica 3 Protecting life, environment and property... AutroSafe, the unique distributed system Booster AutroLON communication network LAN LON Operator Panel Controller Controller Info Panel ALARM ALARM Fire ext.. acktivated Fire Brig. recvd. Prewarning Earlywarning Fault Systemfault Functiondisabled Test Fire ext. aktivated Silence buzzer Fire vent. activ. Power More Alarms INFORMASJONSPANEL Silence buzzer Fire vent. activ. Silence sounders Fire Brig. recvd. Reset More Alarms Autronica Power 1 2 3 4 5 6 7 8 9 BN- 35 Autronica B RANN ALAR M C 0 Tilpasningsenhet FIRE ALARM Interface unit Nr. No. ? Self Verify KNUS GLASSET TRYKK HER I/O PRESS HERE BREAK GLASS Autronica BN- 35 B RANNALARM Tilpasningsenhet FIRE ALARM KNUS GLASSET TRYKK HER KNUS GLASSET Autronica PRESS HERE TRYKKHER BREAK GLASS PRESS HERE BREAK GLASS Interface unit KNUS GLASSET TRYKK HER PRESS HERE N r. BREAK GLASS No. Autronica BN- 35 BN- 35 BRANNALARM BRANNALARM Tilpasningsenhet Tilpasningsenhet FIRE ALARM FIRE ALARM Interface unit Interface unit BN- 35 BRANNALARM Tilpasningsenhet FIRE ALARM Interface unit KNUS GLASSET Nr. TRYKK HER Nr. No. No. PRESS HERE BREAK GLASS Nr. No. Autronica ALARM Repeater Panel ALARM INFORMASJONSPANEL Fire ext.. acktivated Fire Alarm Fire Brig. recvd. Prewarning Earlywarning Fault Systemfault Functiondisabled Test Controller Fire ext. aktivated Silence buzzer Fire vent. activ. Fire Brig. recvd. Power More Alarms Panel Autromaster 5000 Silence buzzer Fire vent. activ. Power More Alarms Silence sounders Reset 1 2 3 4 5 6 7 8 9 C 0 ? Self Verify 4 Protecting life, environment and property... EN-54 Regulations ALARM Fire ext.. acktivated Silence buzzer Fire vent. activ. More Alarms Fire Brig. recvd. Silence sounders Reset Power Prewarning Early warning Fault Systemfault Function disabled 1 2 3 4 5 6 7 8 9 C 0 Test ? Self Verify Autronica Construction General system requirements: • Maximum 512 points shall be lost at one system failure (main processor failure) • One fault in a random loop ( i.g. detector or alarm loop), shall not affect the control panel unit or any other loop • One fault in a random loop ( i.g. detector or alarm loop), shall not affect the control panel unit or any other loop • When more than 32 points are installed in one loop, one failure shall not cause the loss of more than 32 points Autronica KNU S G LASSET TRYKK HER PRESS HERE BREAK GLASS BN- 35 B RANNALARM Tilpasningsenhet FIRE ALARM Interface unit N r. No. Autronica 5 Protecting life, environment and property... Interactive Fire Alarm System: ALARM Î Duplex communication in the detector loop Fire ext.. acktivated Silence buzzer Fire vent. activ. More Alarms Fire Brig. recvd. Silence sounders Reset Power Prewarning Early warning Fault Systemfault Functiondisabled 1 2 3 4 5 6 7 8 9 C 0 Test ? Self Verify Î Data processing in every point Î Decision about incidents is taken by the point in the detector loop Autronica Î Display must show Alarm, Fault, Disablement and test at the same time Autronica K NU S G LA SSET TRYKK HER Î Safety-polling from the control panel PRESS HERE B REAK GLASS BN- 35 B R AN N ALA RM Tilpasningsenhet FIRE ALARM Interfa ce unit N r. N o. Autronica 6 Protecting life, environment and property... Automatic Addressing: ALARM Fire ext.. acktivated Each detector has a uniqe ID, and automatic addressing gives fast commissioning, fewer faults and easy retrofit Silence buzzer Fire vent. activ. Fire Brig. recvd. IDENTITETSKORT Multi Sensor Silence sounders More Alarms Reset Power Prewarning Early warning Fault Systemfault Function disabled SENSOR MULTI 1 2 3 14 05 17 4 5 6 NRR <123 004 567 8< 246 DES 00 7 8 9 C 0 Test ? Self Verify 7 When powering up, the system will automatically find all units “ID’s”, register and “remember”... 1 008199827600125 001199828000346 2 004199828001125 …and simultaneously register each detectors place in the loop 3 006199828001025 6 KNUS GLASSET TRYKK HER PRESS HERE BREAK GLASS 4 BN- 35 BRANNALARM Tilpasningsenhet 007199828000725 008199827600126 FIRE ALARM Interface unit Nr. No. 5 001199828000025 7 Protecting life, environment and property... ID Panels, displays and controllers with SelfVerify: Maximum flexibility. Simple to read, understand and operate. Operator’s Panel Connected to AUTROLON Operates/controls the whole Fire Alarm System, or parts of it All panels have 16x40 character information displays Repeater panel Connected to AUTROLON Controls part of the Fire Alarm System Information Panel Connected to AUTROLON System information only Loop Controller Connected to AUTROLON Controls detector loops and I/O-functions 8 Protecting life, environment and property... Complete range of products for any application Series Units Heat detectors Optical smoke detectors High sensitive smoke detectors Multisensor smoke detectors Manual call points Interface/ address units Sounder Series 200 Standard Interactive Addressable units Series 300 With SelfVerify functions Series 500 With special protection for marine-, offshore-, exi-applications 9 Protecting life, environment and property... SelfVerify, why? Statistics from Offshore: 40% of all critical faults are faults on detectorchamber or electronics. Depending of system type, some or none of these failures are not detected. 45% of all critical faults are functions left disconnected after manual testing. 5% are detectors painted over and hence do not function. Life Cycle Cost: Depending on system type, test periods, etc: Savings 30 – 70% Same type of faults are expected on landbased systems, savings in Life Cycle Costs are however not supposed to be the same. Better service should mean savings. 10 Protecting life, environment and property... Why Self Verification onshore • Onshore security – Same failure rates expected – Inhibit problem, due to testing – Higher system reliability. Simpler and more reliable maintenance • Onshore cost. – Not the same figures, but still possible to reduce cost on service 11 Protecting life, environment and property... What is Self Verification ® 12 Protecting life, environment and property... Standard analogue, addressable Fire Alarm System Power supply Supply Detector Loop Monitored parts Communication Communication interface interface Smoke detector Communication interface Fault Warning warning Fault Fault Signal signal Fault ALARM! Fire Alarm Fire Alarm Signal signal STOP! Detector smoke chamber Operation Alarm Alarm signal signal Signal handling Detector test with test gas 13 Protecting life, environment and property... SelfVerify: Fail safe detectors gives increased reliability and reduce maintenance cost dramatically Power supply SVcontrol Communicationinterface Communicationinterface Smoke detector Signal processing Fault warning Fault signal ALARM! Fire Alarm Fire Alarm Signal STOP! Operating SelfVerify stimulator Detector smokechamber Alarmsignal Monitored part 14 Protecting life, environment and property... MultiSensor Smoke Detector: Fastest and most reliable notification of an incipient fire SENSITIVITY Heat compensated PARTICLE SIZE = Ion Smoke Detector = Optical Smoke Detector = MultiSensor Detector 15 Protecting life, environment and property... Detectors adapted to the local environment: Faster warning and fewer unwanted alarms T NT N E E NM O NM VIR RO N I V LE N A E RI L T S A DU RM N I NO EN VI RO NM EN T A A CL EA N SENSITIVITY ENVIRONMENT ADAPTATION SMOKE DENSITY 16 Protecting life, environment and property... DYFI+ functions: Reliable and fast alarm of slow fire development SENSITIVITY SMOLDERING FIRE FILTER A A TIME = MEASURED VALUE = PROCESSED VALUE 17 Protecting life, environment and property... DYFI+ functions: Filters out misleading phenomena that result in unwanted alarms SENSITIVITY TRANSIENT FILTER A A TIME = MEASURED VALUE = PROCESSED VALUE 18 Protecting life, environment and property... DYFI+ functions: Fault warning before unwanted alarm or “dying” detector SENSITIVITY POLLUTION FILTER A A TIME = MEASURED VALUE = PROCESSED VALUE 19 Protecting life, environment and property...