Preview only show first 10 pages with watermark. For full document please download

Injectors Data Sheet

   EMBED


Share

Transcript

DATA SHEET ExtremeSwitching™ Industrial Power Over Ethernet (PoE) Injectors Industrial Networking Designed for industrial use, Extreme mid-span Power over Ethernet Injectors provide continuous uptime, manageability and operational efficiency. With models supporting IEEE 802.3af and 802.3at and a model support a dedicated 75W output the devices are excellent choice to power PoE devices such as IP cameras, WLAN access points and sensors. Features • INJ-75W-24 Model • Up to 75 Watts Power-over-Ethernet • INJ-30W-24 Model • IEEE802.3af/at Compliant • Up to 30 Watts of High Power-over-Ethernet • 10/100/1000Mbps for PoE OUT and DATA IN • Two DC Inputs for Power Redundancy • 20VDC – 60VDC • Industrial Rated IP30 • -40 to 75°C Operating Temperature Range • Din-Rail and Wall Mount INJ-30W-24 Output Input A and B 54V 54V Rated Current 0.6A 1.4A Current Range 0~0.6A 0~1.4A Rated Power 30W 75W 4-Pair Powering 4/5 (+), 7/8 (-) 1/2 (-) and 3/6 (+) Spare Pairs 4/5 (+), 7/8 (-) Gigabit LAN Port Yes Yes IEEE 802.3af/at Compliant Yes No Operation Voltage 20Vdc~60Vdc 20Vdc~60Vdc DC Current (Full Load) Operating Temperature Environment Operating Humidity Storage Temperature, Humidity Other INJ-75W-24 DC Voltage 4A/24Vdc -40~ 75°C 5 ~ 90% RH Non-condensing -40 ~ +85°C, 10 ~ 95% RH 4A/24Vdc -40~ 75°C 5 ~ 90% RH Non-condensing -40 ~ +85°C, 10 ~ 95% RH Dimension 100 *31* 140mm (L*W*H) 100 *31* 140mm (L*W*H) Weight 350g 350g DC Connector 6-Contact Terminal Block 6-Contact Terminal Block Data In / PoE Out RJ45 Shielded Socket RJ45 Shielded Socket Industrial PoE Injectors – Data Sheet 1 REGULATORY AND SAFETY International EMC Certifications • CISPR 32 Class A (International Emissions) North American ITE • UL 60950-1 2nd Ed., Listed Device (U.S.) • CISPR 24 Class A (International Immunity) • UL 61010-2-201, Listed Device (U.S.) • IEC/EN 61000-4-2 Electrostatic Discharge, 6kV Contact, 8kV Air, Criteria B • CSA 22.2 #60950-1-03 2nd Ed. (Canada) • IEC/EN 61000-4-3 Radiated Immunity 20V/m, Criteria A International ITE • CB Report & Certificate per IEC 60950-1 2nd Ed. + National • IEC/EN 61000-4-4 Transient Burst, 4 kV, Criteria A • IEC/EN 61000-4-5 Surge, 1kV DC Input, 2kV Ethernet Ports Differences Criteria B European Safety • IEC/EN 61000-4-6 Conducted Immunity, 0.15-80 MHz, 10V • EN 60950-1 RMS, Criteria A • 2014/35/EU LVD Directive • IEC/EN 61000-4-8 Power Frequency Magnetic Field Immunity, 300 A/m, Criteria A EMI/EMC STANDARDS • IEC/EN 61000-4-9 Pulsed Magnetic Field Immunity, 300 North American EMC for ITE • FCC CFR 47 part 15 Class A (USA) • ICES-003 Class A (Canada) European EMC Standards A/m, Criteria A • BSMI (Taiwan) • KCC (Korea) • CU (Russia, Belarus, Kazakhstan) • EN 61000-6-2 ROHS AND WEEE • EN 55011 • 2011/65/EU RoHS Directive (Pb free) and WEEE compliant • EN 55032 • EN EN 55024 • 2014/30/EU EMC Directive Order Information PART NUMBER NAME DESCRIPTION 16805 POE INJ–75W–24 24VDC GbE PoE injector with 60/75W output Operating Temperature -40C - +75C 16806 POE INJ–30W-24 24VDC GbE PoE injector with 30W output Operating Temperature -40C - +75C http://www.extremenetworks.com/contact Phone +1-408-579-2800 ©2016 Extreme Networks, Inc. All rights reserved. Extreme Networks and the Extreme Networks logo are trademarks or registered trademarks of Extreme Networks, Inc. in the United States and/or other countries. All other names are the property of their respective owners. For additional information on Extreme Networks Trademarks please see http://www.extremenetworks.com/company/legal/trademarks. Specifications and product availability are subject to change without notice. 10928-0916-23 WWW.EXTREMENETWORKS.COM Industrial PoE Injectors – Data Sheet 2