Preview only show first 10 pages with watermark. For full document please download

Inpower Llc

   EMBED


Share

Transcript

OWER InP the systems people Power Products Accessories Mega Fuses Mega fuse, 32 volt, fast acting. Use fuse holder FH-01. Amps Part No. FM-080 FM-100 FM-125 FM-150 FM-175 FM-200 FM-225 80 100 125 150 175 200 225 The Mega fuses and FH-01 fuse holder are recommended for use with InPower’s ABS Series Auxiliary Battery Switches. Note that each battery cable between the two batteries and the ABS module must contain a fuse within 16 inches of the battery. Mega Fuse Holder Part No. FH-01 Fuse holder for Mega fuses. • Maximum amperage 250 amps @ 12 volts • Red glass-filled nylon base • 5/16 - 18 stainless steel studs • Includes two red TB25-2 terminal boots • For cable sizes 8 - 2 gage The Mega fuses and FH-01 fuse holder are recommended for use with InPower’s ABS Series Auxiliary Battery Switches. Note that each battery cable between the two batteries and the ABS module must contain a fuse within 16 inches of the battery. Terminal Insulator Boots Power terminal insulator boots for use on InPower products for protection against accidental shorting. • Molded red vinyl • Tapered cable entry seal Part No. TB28-2 TB28-3 TB25-2 Cable Size 8 - 2 Gage 2 - 2/0 Gage 8 - 2 Gage InPower Product Reference SSC20, SSC42, LVD20, ABS SSC20, SSC42, LVD20, ABS FH-01 These terminal insulating boots are recommended for use with InPower SSC Series Solid State Contactors, LVD20 Series Low Voltage Disconnects and ABS Series Auxiliary Battery Switches. Product Data Sheet PDS-125A Power Products Accessories Power Distribution Post Part No. PDP-01 • • • • Red, glass-filled Nylon 3/8 inch stainless steel stud Maximum voltage 48 Vdc Maximum current 160 amps Used to terminate multiple high current DC cables. Recommended for use in electrical systems containing InPower SSC Series Solid State Contactors, LVD20 Series Low Voltage Disconnects and ABS Series Auxiliary Battery Switches (these products are not intended to have more than one cable per terminal). Fuse/Distribution Module Part No. FDM-01 • Ground terminal pad with #10-32 threaded stud • #10-32 threaded power input stud • Six power circuit positions • Uses ATC fuses (not supplied with product) • 100 amps maximum (combined circuits) • 1/4 inch push-on terminals • 20 amp maximum per output circuit Recommended for use in InPower VCMS switch panel systems to provide fused power to the VCMS power modules (each power module requires three 20 amp fused power inputs). The FDM-02 contains a ground distribution circuit. Fuse/Distribution Module Part No. FDM-02 • • • • • • #10-32 threaded power input stud Six power circuit positions Uses ATC fuses (not supplied with product) 100 amps maximum (combined circuits) 1/4 inch push-on terminals 20 amp maximum per output circuit Recommended for use in InPower VCMS switch panel systems to provide fused power to the VCMS power modules (each power module requires three 20 amp fused power inputs). InPower LLC 3555 Africa Road Galena, Ohio 43021 Tel: 740-548-0965 Fax: 740-548-2302 www.InPowerDirect.com PDS-125A 111017 © Copyright 2011 InPower LLC Specifications subject to change without notice. Offered by: