INPUT NODE
Correct in: September 2008
INPUT NODE Page 2
1.0 PRODUCT NAME. _____________________________________3 1.1 ORDER CODE ____________________________________________ 3
2.0 WARNING. ___________________________________________3 2.1 SAFETY _________________________________________________ 3 2.1 FUNCTION TEST __________________________________________ 3
3.0 DESCRIPTION OF FUNCTION. ___________________________4 3.1 MODE OF OPERATION_____________________________________ 4 3.2 CIRCUIT DIAGRAM ________________________________________ 4 3.3 PICTURES AND REPRESENTATIONS ________________________ 4
4.0 COMMISSIONING. _____________________________________5 4.1 CONFIGURATION OF WN.CN.UR.SCHALT ____________________ 5 4.2 POWER SUPPLY: POWER SUPPLY UNIT _____________________ 6
5.0 TECHNICAL DATA. ____________________________________6
Note: SimonsVoss Technologies AG reserves the right to make modifications to the product without notice. Consequently, descriptions and representations in this documentation may vary from the most recent product and software versions. As a general principle, the original German version shall apply in the event of any doubt. Subject to errors and misspellings.
© Copyright SimonsVoss Technologies AG All rights reserved
INPUT NODE Page 3
1.0
PRODUCT NAME.
1.1
ORDER CODE WN.CN.UR.SCHALT, hereafter referred to as INPUT NODE.
2.0
WARNING.
2.1
SAFETY
2.1
In order to install a SimonsVoss INPUT NODE you must be familiar with access control systems, door mechanics, door approvals, electronic assembly, and working with SimonsVoss software. For this reason, installation should only be undertaken by trained specialists.
SimonsVoss Technologies AG shall assume no liability for damage caused by incorrect installation.
Access through a door may be denied if an INPUT NODE is incorrectly installed. SimonsVoss AG shall assume no liability for the consequences of incorrect installation, such as denied access to injured persons or persons at risk, damage to property or any other form of damage.
ESD (electrostatic discharge) guidelines must be observed when installing the INPUT NODE. In particular, avoid touching the PCBs and the integrated circuits on them.
People with electronic medical implants (pacemakers, hearing aids etc.) must always maintain a distance of at least 30 cm between the implant and the INPUT NODE. Specific instructions should be provided to this effect. In the interests of safety, people with electronic implants should seek medical advice as to the potential hazards of radio units (868 MHz).
FUNCTION TEST Perform a function test at least once per week. Make sure that all components can be operated faultlessly.
INPUT NODE Page 4
3.0
DESCRIPTION OF FUNCTION.
3.1
MODE OF OPERATION The INPUT NODE can transmit either a remote opening or emergency activation to a lock node or directly networked cylinder by radio. An external switching contact (normally open contact, see 3.2) initiates transmission of a remote opening or emergency activation. This function replaces the switching transponder (TRA.SCHALT), and no wiring is therefore required.
3.2
CIRCUIT DIAGRAM
white = emergency activation
USB interface
green = remote opening
brown = earth
•
External contact (potential-free)
230V/USB Power supply (5V DC) 3.3
PICTURES AND REPRESENTATIONS The pictures or schematic representations used in this manual may vary in some of their details from the devices supplied.
INPUT NODE Page 5
4.0
COMMISSIONING.
4.1
CONFIGURATION OF WN.CN.UR.SCHALT Connect the WN.CN.UR.SCHALT to the PC / laptop with the USB data cable.
Install USB driver; see manual for WN.CN.U(X)
Initial programming of lock with SmartCD
Network configuration; see system manual
Network Æ Activation of lock Æ Remote opening
Enter locking plan password and click on “Execute”
After executing, the INPUT NODE is fully configured
Perform function test using the switching contacts provided!!!
INPUT NODE Page 6
4.2
5.0
POWER SUPPLY: POWER SUPPLY UNIT
Remove USB data cable
Connect supplied plug-in power supply (230V / USB 5V DC controlled)
Left LED flashes red twice
Test to make sure unit is functioning properly
TECHNICAL DATA. Order number
WN.CN.UR.SCHALT
Description
WaveNet central node with 868 MHz radio interface and external antenna
Dimensions (L*W*H)
100 x 65 x 40 mm or 100 x 65 x 130 mm (with antenna)
Power supply
Power supply unit, 230V AC / USB 5V DC, controlled
Output
Min. 3 VA (250 mA with continuous load)
Maximum transmission power
5 dBm (3.16 mW) at antenna socket
Sensitivity
-90 dBm at 19.2 kBaud
Frequency band
868 MHz
Power consumption in receiver mode 12 mA at 9 V