Transcript
CB1210A Battery Charger
Technical features
Input Data
The CB series is a “Switching technology” and “Battery Care philosophy”, since years parts of the core know-how at ADEL system, led to the development of this advanced multi-stage battery charging method, completely automatic and suited to meet the most advanced requirements of battery manufacturers. The Battery Care concept is base on algorithms that implement rapid and automatic charging, battery charge optimization during time, flat batteries recovery and real time diagnostic during installation and operation. The Real Time Autodiagnostic system, monitoring battery faults such as, elements in short circuit, accidental reverse polarity connection, disconnection of the battery, they can easily be detected and removed by help of Blink Code of Diagnosis Led; during the installation and after sell. Each device is suited for all battery types, by means of jumpers it is possible setting predefined curves for Open Lead Acid, Sealed Lead Acid, Gel, NiCd(option). They are programmed for two charging levels, boost and trickle. A rugged casing with bracket for DIN rail mounting provide IP20 protection degree.
General Data
Insulation voltage (In /Out) Insulation voltage (In / PE) Insulation voltage (Out / PE) Protection Class (EN/IEC 60529) Protection class Reliability: MTBF IEC 61709 Pollution Degree Environment Connection Terminal Blocks screw Type Dimensions (w-h-d) Weight
3000 Vac 1605 Vac 500 Vac IP20 I, with PE connected > 300.000 h 2 2,5mm(24–14AWG) 65x115x135 mm 0.65 Kg approx
Ambient temperature (operation) De Rating Ta > 50°C Ambient temperature Storage Humidity at 25 °C no condensation Cooling
-25 ÷ +70°C - 2.5%(In) / °C -40 ÷ +85°C 95% to 25°C Auto Convention
Climatic Data
Norms and Certifications
Conforming to:IEC/EN 60335-2-29,EN60950/UL1950,Electrical safety,89/336/EEC,EMCDirective,2006/95/EC (Low Voltage),DIN41773 (Charging cycle),Emission:IEC 61000-6-4,Immunity: IEC 61000-6-2.CE
Signal Output (free switch N°2 contact) Main or Backup Power Low Battery Fault Battery
Input: Single-phase 115 230 Vac Output: Battery charging 12 Vdc; 10 A Suited for the following battery types: Open Lead Acid, Sealed Lead Acid, lead Gel and Ni-Cd (option) Automatic diagnostic of battery status. Charging curve IUoUo, constant voltage and current Switching technology, output voltage 14.4 Vdc Three charging levels: Boost, Trickle, Recovery. Protected against short circuit, inverted polarity, over Load. Signal output (contact free) for fault battery state Protection degree IP20 - DIN rail
Yes Yes Yes
Nominal Input Voltage (2 x Vac) Input Voltage range (Vac) Inrush Current (Vn and In Load) I2t Frequency Input Current (115 – 230 Vac) Internal Fuse External Fuse (recommended)
115 – 230 90 – 305 16 A 5 msec. 47 – 63 Hz 6% 2.4 – 1.2 A 4A 10 A (MCB curve B)
Battery Output (Battery Care) Boost charge (25 °C) (Typ. at In) Max. time Bust Charge (tpy. At In) Min. time Bust Charge (tpy. At In) Trickle charge (25 °C) (Typ. at In) Jumper Configuration battery type (V cell) Ni-Cd (optional) Recovery Charge Charging. Max Ibatt (In) Efficiency (50% of In) Charging current limiting Iadj Quiescent Current Charging Curve automatic: IUoUo Detection of element in short circuit Short-circuit protection) Over Load protection Over Voltage Output protection
14.4 Vdc 15 h 1 min. 13.75 Vdc 2.23;2,25;2,27;2,3; 1,41–1,5 (20 elem.) 2 – 9 Vdc 10 A 5% 89% 20 ÷ 100 % / In 5 mA 3 stage Yes Yes Yes Yes
Charging Aautomatic multi-stage charging and real time diagnostic allow fast recharge and recovery of deep discharged batteries, adding value and reliability to the system hosting. Type of charging it is Voltages and current stabilized IUoUo. The state of charging battery and Autodiagnosis of the systems are identified by a flashing code on a Diagnosis LED and Fault Battery LED: State Diagnosis LED Battery Fault LED Trickle 1 Blink/sec OFF Charging Boost 2 Blink/sec OFF Type Recovery 5 Blink/sec OFF Reverse polarity ON 1Blink Battery No connect 2Blink ON Auto ON diagnosis Element in Short C. 3Blink Replace Battery ON 5Blink
Type of Signal Output Contact Max. current can be switched (EN60947.4.1): Max. DC1: 30 Vdc 1 A; AC1: 60 Vac 1A Min.1mA at 5 Vdc
Resistive load Min. load
All specifications are subject to change without notice