Preview only show first 10 pages with watermark. For full document please download

Install Drawing For Model 3144p Temp. Transmitter 14 1

   EMBED


Share

Transcript

1 A 2 4 3 6 5 9 8 7 10 14 13 12 11 15 16 REVISION TABLE ROSEMOUNT 3144P TEMPERATURE TRANSMITTER REVISION ECO NO. APP'D DATE AD RTC1056398 JR 4/3/13 A DESCRIPTION CONVERT TO PRO-E B B SHOWN WITH 1/2-14 NPT CONDUIT THREAD SHOWN WITHOUT OPTIONAL DIGITAL DISPLAY SHOWN WITH OPTIONAL DIGITAL DISPLAY 4.33 [110] 4.02 [102] 5.12 [130] C C .43 [11] D FIELD TERMINALS (THIS SIDE) .63 [16] D 1/2-14 NPT CONDUIT CONNECTION (2 PLACES) 4.37 [111] EXPLOSION/FLAME PROOF CLAMP (OPTION CODE DEPENDENT) E E .89 [22] 1/2-14 NPT 4.40 [112] F DIGITAL DISPLAY COVER TRANSMITTER ELECTRONICS (THIS SIDE) 3/8-16 UN-2B F G G SHOWN WITH OPTIONAL JIS G 1/2 CONDUIT ADAPTER SHOWN WITH OPTIONAL M20 X 1.5 OR PG 13.5 CONDUIT ADAPTER CAL. CERTIFICATION LABEL H H NOT INSTALLED JIS G 1/2 CONDUIT ADAPTER M20 X 1.5 OR PG 13.5 CONDUIT ADAPTER NOT INSTALLED 03144-0111 J TAG NO. EXTERNAL GROUND SCREW (OPTION CODE DEPENDENT) 1. FORM REV AA M .75 [19] CLEARANCE REQUIRED TO REMOVE COVERS. ROSEMOUNT INC. CERTIFIES THESE DRAWINGS ARE IN ACCORDANCE WITH ROSEMOUNT ENGINEERING SPECIFICATIONS AND ACCURATELY REPRESENT THE EQUIPMENT FURNISHED. NOTES: L CUSTOMER INFORMATION WITHIN THIS DOCUMENT MAY CHANGE WITHOUT NOTICE. NOT INTENDED FOR ENGINEERING USE. REFERENCE ROSEMOUNT PRODUCT DATA SHEETS FOR ENGINEERING INFORMATION. 2. 7.00 [178] CONFIDENTIAL AND PROPRIETARY INFORMATION IS CONTAINED HEREIN AND MUST BE HANDLED ACCORDINGLY. EMERSON L 6.81 [173] UNLESS OTHERWISE SPECIFIED DIMENSIONS IN INCHES [mm]. 2.20 [56] K DRAWING NO. K J CUSTOMER DWG NO. P.O. No. S.O. No. PROJECT NAME DO NOT SCALE PRINT 3RD ANGLE *** SIZE D SCALE REV 1/1 AD *** *** TITLE *** DR. *** APP'D INSTALL DRAWING FOR MODEL 3144P TEMP. TRANSMITTER JLA JR CAD MAINTAINED, (PRO/E) PRODUCT CODE 4/3/13 DRAWING NO. 4/3/13 - DOC TYPE D SHEET 03144-0111 1 OF 2 M 1 A 2 4 3 5 6 7 9 8 10 11 13 12 14 15 16 ROSEMOUNT 3144P TEMPERATURE TRANSMITTER MOUNTING CONFIGURATIONS WITH OPTIONAL MOUNTING BRACKET A PIPE MOUNTING B B C C D D E E F F G G CAL. 4.00 [101] H H 2.00 [51] 3/8-16 BOLT FOR TRANSMITTER MOUNTING 03144-0111 TAG NO. J 3/8-16 BOLT FOR TRANSMITTER MOUNTING K 2 INCH U-BOLT FOR PIPE MOUNTING L CUSTOMER INFORMATION WITHIN THIS DOCUMENT MAY CHANGE WITHOUT NOTICE. NOT INTENDED FOR ENGINEERING USE. REFERENCE ROSEMOUNT PRODUCT DATA SHEETS FOR ENGINEERING INFORMATION. CONFIDENTIAL AND PROPRIETARY INFORMATION IS CONTAINED HEREIN AND MUST BE HANDLED ACCORDINGLY. EMERSON FORM REV AA UNLESS OTHERWISE SPECIFIED DIMENSIONS IN INCHES [mm]. L M K DRAWING NO. 2 INCH U-BOLT FOR PIPE MOUNTING J CUSTOMER DWG NO. P.O. No. S.O. No. PROJECT NAME DO NOT SCALE PRINT 3RD ANGLE *** SIZE D SCALE REV 1/1 AD *** *** TITLE *** DR. *** APP'D INSTALL DRAWING FOR MODEL 3144P TEMP. TRANSMITTER JLA JR CAD MAINTAINED, (PRO/E) PRODUCT CODE 4/3/13 DRAWING NO. 4/3/13 - DOC TYPE D SHEET 03144-0111 2 OF 2 M