Preview only show first 10 pages with watermark. For full document please download

Installation Diagrams

   EMBED


Share

Transcript

SECTION 6 (Rev. A) INSTALLATION DIAGRAMS Download from www.urmet.com Technical Manuals area. INSTALLATION DIAGRAMS This section contains basic connection diagrams for 2VOICE systems. All technical diagrams are available in the site www.urmet.com in the Reserved Area – system technical diagrams. 2 VOICE - Technical Manual sec.6 −−−−  SECTION 6 INDEX INDEX Description Diagram Page DIAGRAMS NUMERIC INDEX....................................................................................................................................................................................3 DIAGRAMS SELECTION TABLES . ...........................................................................................................................................................................4 LIST OF DIAGRAMS NOTES......................................................................................................................................................................................7 DEVICES LIST .........................................................................................................................................................................................................10 Call stations replacement in diagrams...................................................................................................................................................12 Connection of a door phone riser to 1 call station (floor connection in parallel)........................................................................................................................................... SC124-0278......................13 Connection of a column with 4 door phone risers max to 2 call stations (floor connection in parallel)........................................................................................................................................... SC124-0280......................14 Connection of a column with 4 door phone risers max. to 4 call stations (floor connection in parallel).........................................................................................................................................SC124-0281A......................15 Connection of 16 columns max. with door phones to 1 main call station Each group is connected to 1 or 2 secondary call stations (floor connection in parallel)........................................................................................................................................... SC124-0296......................16 Connection of N columns with door phones to 4 main call stations max. Each group is connected to 1 or 2 secondary call stations (floor connection in parallel).........................................................................................................................................SC124-0282A......................18 Connection of a riser with video door phones and door phones to 1 call station (floor connections with 4-user distributor) ..................................................................................................................SV124-0954B......................20 CONNECTION OF A COLUMN WITH 4 VIDEO DOOR PHONES/DOOR PHONES RISERS MAX. TO 2 Call stations. (floor connections with 4-user distributor)...................................................................................................................SV124-0955B......................21 CONNECTION OF A COLUMN WITH 4 VIDEO DOOR PHONES/DOOR PHONES RISERS MAX. TO 4 MAIN Call stations................................................................................................................SV124-0997B......................22 CONNECTION OF N COLUMNS, EACH ONE WITH 4 VIDEO DOOR PHONES/DOOR PHONES RISERS MAX., TO 1 MAIN Call station. (each column is connected to 1 or 2 secondary call stations).....................................................................................SV124-0962B......................24 CONNECTION OF N COLUMNS, EACH ONE WITH 4 VIDEO DOOR PHONES/DOOR PHONES RISERS MAX., TO 4 MAIN Call stations. (each column is connected to 1 or 2 secondary call stations).....................................................................................SV124-0963C......................26 Connection of a riser with video door phones and door phones to 1 switchboard and 1 call station............................................................................................................... SV124-1098......................28 Connection of a column with 4 risers max. of video door phones and door phones to 1 switchboard and 4 call stations............................................................................................................. SV124-1155......................29 CONNECTION OF A RISER WITH VIDEO DOOR PHONES AND DOOR PHONES TO 1 SWITCHBOARD AND TO 4 MAIN CALL STATIONS MAX.................................................................................... SV124-1156......................30 Connection of 16 columns max. with video door phones and door phones to 1 switchboard and 1 main call station (each column is connected to 1 or 2 secondary call stations)..................................................................................... SV124-1100A......................32 INSTALLATION DIAGRAMS Connection of N columns with video door phones and door phones to 1 switchboard and 4 main call stations max. (each column is connected to 1 or 2 secondary call stations)..................................................................................... SV124-1099A......................34 Connection of a door phone riser to 1 switchboard and 1 call station (floor connection in parallel)........................................................................................................................................... SC124-0307......................36 CONNECTION TO A Call station WITH: A1) 2 CONTROL CAMERAS B1) 5 CONTROL CAMERAS......................................................................................................................................... SV124-1020A......................37 CALL REPEAT EXAMPLES: A) C) D) Without timing B) With timing from 1 to 30s........................................................................................................................................... SV124-1024......................39 Examples of switchboard call repeat: A) With additional ringer Ref. 1072/59 B) With electronic ringer Ref. 9854/40 and timing from 1 to 30s.................................................................................. SV124-1118......................40  −−−− sec.6 2 VOICE - Technical Manual SECTION 6 INDEX Examples of switchboard call repeat: C) With 5A/100Vdc max. load with relay box Ref. 788/52 D) With 1A/24Vdc max. load with relay box Ref. 788/52............................................................................................... SV124-1118......................41 CONNECTION OF A RELAY TO A Call station TO ACTIVATE AN ADDITIONAL ELECTRIC LOCK..................... SV124-1026A......................42 CONNECTION OF AN ADDITIONAL ELECTRIC LOCK A) activated at the same time as the system one B) manual independent activation (button).................................................................................................................. SV124-1029A......................43 Connection of 5 control cameras to one call station........................................................................ SV124-1089A......................44 Connection of 5 control cameras to one call station.......................................................................... SV124-1113......................45 Special decoder connection and programming with connection derived by the distributor.................................................................................................................................................. SV124-1157......................46 Special decoder connection and programming with connection between door units interface and column interface .............................................................................................. SV124-1157......................49 Connection of N columns with video door phones and door phones with 8 distributors max. to one riser of the door units interface ............................................................. SV124-1164......................52 Connection of N columns with video door phones and door phones with 4 distributors max. to one riser of the door units interface.............................................................. SV124-1165......................54 Replacement of a video door phone call station with a door phone one equipped with an additional camera................................................................................................................ SV124-1158......................56 DIAGRAMS NUMERIC INDEX SV124-0954B...........................................................................................................................................................................................................20 SV124-0955B...........................................................................................................................................................................................................21 SV124-0962B...........................................................................................................................................................................................................24 SV124-0963C...........................................................................................................................................................................................................26 SV124-0997B...........................................................................................................................................................................................................22 SV124-1020A...........................................................................................................................................................................................................37 SV124-1024..............................................................................................................................................................................................................39 SV124-1026A...........................................................................................................................................................................................................42 SV124-1029A...........................................................................................................................................................................................................43 SV124-1089A...........................................................................................................................................................................................................44 SV124-1098..............................................................................................................................................................................................................28 SV124-1099A...........................................................................................................................................................................................................34 SV124-1100A...........................................................................................................................................................................................................32 SV124-1113..............................................................................................................................................................................................................45 SV124-1118..............................................................................................................................................................................................................41 SV124-1155..............................................................................................................................................................................................................29 SV124-1156..............................................................................................................................................................................................................30 SV124-1157..............................................................................................................................................................................................................46 SV124-1158..............................................................................................................................................................................................................56 SV124-1164..............................................................................................................................................................................................................52 SV124-1165..............................................................................................................................................................................................................54 2 VOICE - Technical Manual sec.6 −−−−  INSTALLATION DIAGRAMS Diagrams Page SC124-0278.............................................................................................................................................................................................................13 SC124-0280.............................................................................................................................................................................................................14 SC124-0281A...........................................................................................................................................................................................................15 SC124-0282A...........................................................................................................................................................................................................18 SC124-0296.............................................................................................................................................................................................................16 SC124-0307.............................................................................................................................................................................................................36 DIAGRAM SELECTION TABLES DIAGRAM SELECTION TABLES DOOR PHONE SYSTEMS DIAGRAMS Secondary Main Call stations (PE) No. of columns (K) Max. distance between PE and apartment station System max. extension No. of column interfaces Ref.1083/50 No. of door units interfaces Ref.1083/75 Diagram Page 1with switchboard 800m 800m 0 0 SC124-0307 (*) 36 800m 800m 1000m 1600m 800m 800m 800m 800 + 400m 800 + 600 + 400m 800xK +200m 0 1 0 1 K 0 0 1 1 0 SC124-0278 (*) SC124-0280 SC124-0281A SC124-0282A SC124-0296 13 14 15 18 16 1400m 800xK + 400 + 400m K 1 SC124-0282A 18 1400m 800xK + 800 + 400m K 1 SC124-0282A 18 1600m 800xK + 2400 + 400m K 1 SC124-0282A 18 800m 800xK +200m K 0 SC124-0296 16 1400m 800xK + 400 + 400m K 1 SC124-0282A 18 1400m 800xK + 800 + 400m K 1 SC124-0282A 18 1600m 800xK + 2400 + 400m K 1 SC124-0282A 18 < 800m 1000m 800m 800 + 800m 1 0 0 1 SC124-0280 SC124-0281A 14 15 1400m 800xK + 400 + 800m K 1 SC124-0282A 18 1400m 800xK + 800 + 800m K 1 SC124-0282A 18 1600m 800xK + 2400 + 800m K 1 SC124-0282A 18 1000m 800 + 1200 m 0 1 SC124-0281A 15 1400m 800xK + 400 + 1200m K 1 SC124-0282A 18 1400m 800xK + 800 + 1200m K 1 SC124-0282A 18 1600m 800xK + 2400 + 1200m K 1 SC124-0282A 18 1000m 800 + 1600m 0 1 15 1400m 800xK + 400 + 1600m K 1 1400m 800xK + 800 + 1600m K 1 1600m 800xK + 2400 + 1600m K 1 SC124-0281A SC124-0282A (*) SC124-0282A (*) SC124-0282A (*) 1 0 1 2xK max 0 2 2xK max 0 3 2xK max 0 INSTALLATION DIAGRAMS 4 2xK max 16 max 20 max on 1 branch 32 max on 2 branches 32 max on 4 branches 16 max 20 max on 1 branch 32 max on 2 branches 32 max on 4 branches 1 20 max on 1 branch 32 max on 2 branches 32 max on 4 branches 1 20 max on 1 branch 32 max on 2 branches 32 max on 4 branches 1 20 max on 1 branch 32 max on 2 branches 32 max on 4 branches 18 18 18 (*) not expandable system  −−−− sec.6 2 VOICE - Technical Manual DIAGRAM SELECTION TABLES no 0 1 yes no 2xK max yes no 0 yes 2 no 2xK max yes 0 3 no yes no 2xK max yes 0 4 no yes no 2xK max yes No. of columns (K) Max. distance between PE and apartment station System max. extension No. of column interfaces Ref.1083/50 No. of door units interfaces Ref.1083/75 Diagram Page 1 1 1 1 16 max 20 max on 1 branch 32 max on 2 branches 32 max on 4 branches 1 1 1 1 16 max 20 max on 1 branch 32 max on 2 branches 32 max on 4 branches 16 max 20 max on 1 branch 32 max on 2 branches 32 max on 4 branches 16 max 20 max on 1 branch 32 max on 2 branches 32 max on 4 branches 1 1 1 1 20 max on 1 branch 32 max on 2 branches 32 max on 4 branches 20 max on 1 branch 32 max on 2 branches 32 max on 4 branches 1 1 20 max on 1 branch 32 max on 2 branches 32 max on 4 branches 20 max on 1 branch 32 max on 2 branches 32 max on 4 branches 1 1 20 max on 1 branch 32 max on 2 branches 32 max on 4 branches 20 max on 1 branch 32 max on 2 branches 32 max on 4 branches 400m 400m 400m 1000m 400m 800m 800m 1000m 400m 400m 400m 1000m 400m 800m 800m 1000m 400m 800m 800m 1000m 400m 800m 800m 1000m 400m 400m 400m 400m 800m 800m 1000m 800m 800m 1000m 400m 400m 800m 800m 1000m 800m 800m 1000m 400m 400m 800m 800m 1000m 800m 800m 1000m 800m 800m 800 + 200m 800 + 600 + 200m 800xK +200m 800xK + 400 + 200m 800xK + 800 + 200m 800xK + 2400 + 200m 800m 800m 800 + 200m 800 + 600 + 200m 800xK +200m 800xK + 400 + 200m 800xK + 800 + 200m 800xK + 2400 + 200m 800xK +200m 800xK + 400 + 200m 800xK + 800 + 200m 800xK + 2400 + 200m 800xK +200m 800xK + 400 + 200m 800xK + 800 + 200m 800xK + 2400 + 200m 800m 800 + 400m 800m 800 + 400m 800xK + 400 + 400m 800xK + 800 + 400m 800xK + 2400 + 400m 800xK + 400 + 400m 800xK + 800 + 400m 800xK + 2400 + 400m 800 + 600 m 800 + 600 m 800xK + 400 + 600m 800xK + 800 + 600m 800xK + 2400 + 600m 800xK + 400 + 600m 800xK + 800 + 600m 800xK + 2400 + 600m 800 + 800m 800 + 800m 800xK + 400 + 800m 800xK + 800 + 800m 800xK + 2400 + 800m 800xK + 400 + 800m 800xK + 800 + 800m 800xK + 2400 + 800m 0 1 0 1 K K K K 0 1 0 1 K K K K K K K K K K K K 1 0 1 0 K K K K K K 0 0 K K K K K K 0 0 K K K K K K 0 0 1 1 0 1 1 1 0 0 1 1 0 1 1 1 0 1 1 1 0 1 1 1 0 1 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 SV124-0954B (*) SV124-0955B SV124-0997B SV124-0963C SV124-0962B SV124-0963C SV124-0963C SV124-0963C SV124-1098 (*) SV124-1155 SV124-1156 SV124-1099A SV124- 1100A SV124-1099A SV124-1099A SV124-1099A SV124-0962B SV124-0963C SV124-0963C SV124-0963C SV124- 1100A SV124-1099A SV124-1099A SV124-1099A SV124-0955B SV124-0997B SV124-1155 SV124-1156 SV124-0963C SV124-0963C SV124-0963C SV124-1099A SV124-1099A SV124-1099A SV124-0997B SV124-1156 SV124-0963C SV124-0963C SV124-0963C SV124-1099A SV124-1099A SV124-1099A SV124-0997B SV124-1156 SV124-0963C SV124-0963C SV124-0963C SV124-1099A (*) SV124-1099A (*) SV124-1099A (*) 20 21 22 26 24 26 26 26 28 29 30 34 32 34 34 34 24 26 26 26 32 34 34 34 21 22 29 30 26 26 26 34 34 34 22 30 26 26 26 34 34 34 22 30 26 26 26 34 34 34 (*) not expandable system 2 VOICE - Technical Manual sec.6 −−−−  INSTALLATION DIAGRAMS Secondary Main Call stations (PE) Switchboard VIDEO DOOR PHONE SYSTEM DIAGRAMS DIAGRAM SELECTION TABLES CONNECTION EXAMPLE CONNECTION EXAMPLE • Control cameras connection SV124-1020A Page 37 es. A 2 max with switching device Ref. 1083/69 5 max with switching device Ref. 1083/69 5 max with switching device Ref. 1038/69 4 max with BUS interface Ref. 1783/69 Sv124-1089A Page 44 SV124-1113 Page 45 es. B ¸ ¸ ¸ ¸ • Call repeat SV124-1024 Page 39 ex. A With ringer Ref.1072/59 ex. B ex. C ex. D ¸ With electronic ringer and timing from 1 to 30” With electric charge up to 5A/100Vdc With electric charge up to 1A/24Vdc ¸ ¸ ¸ With electric charge up to 1A/24Vcc SV124-1118 Page 40 ex. A With ringer Ref.1072/59 ex. B ex. C ex. D ¸ With electronic ringer and timing from 1 to 30” With electric charge up to 5A/100Vdc With electric charge up to 1A/24Vdc ¸ ¸ ¸ • Activation of an additional electric lock SV124-1029 Page 43 ex. A Activated with dedicated button Activate at the same time as the pedestrian door lock ex. B SV124-1026A Page 42 ex. C ¸ ¸ Activated with relay for gate ¸ INSTALLATION DIAGRAMS • Connection of the street side branch with 4-user distributors SV124-1164 Pag. 52 With 8 distributors max. on a branch With 4 distributors max. on a branch SV124-1165 Pag. 54 ¸ ¸ • Ref.1083/80 special decoder connection SV124-1157 Pag. 46 Some examples of connection and programming  −−−− sec.6 ¸ 2 VOICE - Technical Manual LIST OF DIAGRAMS NOTES LIST OF DIAGRAMS NOTES VV.001 - WIRE CROSS-SECTION AREA. C4 .013 - Fit a 9V (MN1604/6LR61) battery in the ringer. The ringer is equipped with two ju mpers indicated by W1 and W2. Re move one of the two jumpers for tw o-tone or one-tone operation as sh own in the following table: FROM OUTDOOR STATION TO POWER SUPPLY OR TO RISER INTERFACE OR TO DOOR UNIT INTERFACE Distance Wires LINE m 200 - - - - - - Used only cable Ref.1083/90 FROM LAST INDOOR SET TO POWER SUPPLY OR RISER INTERFACE Distance TV.001 - For wiring and trimming follow the instructions provided with the device. Wires LINE TV.031 UNTWIST THE CABLES OF ABOUT 20 mm TO MAKE INSTALLATION EASY UTP CAT5 CABLE 200 - - - - - - Used only cable Ref.1083/90 FROM INDOOR SET TO DISTRIBUTOR Distance TV.008 - Insulate the camera from the bracket and/or enclosure with appropriate isolators provided with product. m Wires LINE m 50 - - - - - - Used only cable Ref.1083/90 FROM POWER SUPPLY TO DOOR UNIT INTERFACE OR TO RISER INTERFACE Distance Wires LINE m 5 - - - - - - Used only cable Ref.1083/90 FROM DOOR UNIT INTERFACE TO LAST RISER INTERFACE Distance Wires LINE VD.001 - MINIMUM WIRE SECTION BETWEEN POWER UNIT AND VIDEO DEVICES DISTANCES m Wires R1, R2, +TC Sq.mm COAXIAL CABLE 75 Ohm 50 100 200 400 0,75 1 1,5 2,5 Use a RG 59 coaxial wire for up to 300 m. Use a RG 11 coaxial wire for up to 600 m. Use video amplification devices for longer distances. m 200 - - - - - - Used only cable Ref.1083/90 The maximum distance between the call outdoor station and the most distant indoor set must be: a) 400 m. with or without riser interface. b) 600 m. using door unit interface and riser interface. IMPORTANT NOTES In all cases, to improve interference immunity, do not arrange the system wires near 230V~ and 400V~ power wires which generate strong electromagnetic fields. VD.007 = Floor call button. INSTALLATION DIAGRAMS VD.017 - On switching device set the jumper as written in the table according to the number of used cameras. JUMPER SETTING N. of JP1 cameras JP2 JP3 JP4 Video signal switching 2 ON -- -- -- A1÷A2 3 -- ON -- -- A1÷A2÷A3 4 -- -- ON (*) -- -- A1÷A2÷A3÷A4 5 --ON A1÷A2÷A3÷A4÷A5 (**) (loop through) (*) default setting (**) the pass through camera (A5) must be directly powered 2 VOICE - Technical Manual sec.6 −−−−  LIST OF DIAGRAMS NOTES VV.002 - WIRE CROSS-SECTION AREA FOR AUXILIAR SIGNAL. FROM OUTDOOR STATION TO: - ELECTRIC LOCK Distance m 10 20 30 Wires SE-, SE+ sq.mm 0,28 0,5 1 m 25 - - - - sq.mm 0,28 - - - - m 25 - - - - sq.mm 0,28 - - - - - DOOR OPENER BUTTON Distance Wires PA, CT VV.003 - EXTENSION LIMITS. Following extension limit is suggested: A = Connection between door unit interface and call stations must not exceed 800m. B = Connections between door unit interface and riser interface must not exceed 800m. C = Connections between indoor sets of backbones with riser interface + connections between riser interface with call stations must not exceed 800m. - DOOR SENSOR CONTACT Distance Wires SP, CT C - DEVICE FOR CAMERA TVCC Distance Wires T-, T+ m 300 - - - - sq.mm 0,28 - - - - m 30 50 100 sq.mm 0,28 0,5 1 BACKBONES - DRIVEWAY Distance Wires SE2 Outdoor station (pins ILL) can power maximum 32 name tags. If the number of name tags is greater than 32, use a transfomer of suitable power, with the following sections and maximum distances. Distance m 100 200 300 - - Wires ~0, ~12 sq.mm 1 1,5 2,5 - - B A FROM INDOOR SET TO: - FLOOR CALL BUTTON Distance m 10 - - - - Wires CP sq.mm 0,28 - - - CALL STATION - ADDITIONAL RINGER Distance Wires S-, S+ INDOOR SET m 10 - - - - sq.mm 0,28 - - - - RISER INTERFACE DOOR UNIT INTERFACE INSTALLATION DIAGRAMS VV.004 - Attention: Don't remove the jumper between pins "Z" of the last riser interface.  −−−− sec.6 2 VOICE - Technical Manual LIST OF DIAGRAMS NOTES VV.009 - WIRE CROSS-SECTION . AREA VV.006 - EXTENSION LIMITS. Following extension limit is suggested: A = Connection between outdoor station and last riser interface must not exceed 200m. C = Connections between indoor sets of riser with riser interface + connections between riser interface with outdoor stations must not exceed 800m. FROM OUTDOOR STATION TO POWER SUPPLY OR TO RISER INTERFACE OR TO DOOR UNIT INTERFACE Distance 200 - - - - - - Wires LINE Used only cable Ref.1083/90 FROM LAST INDOOR SET TO POWER SUPPLY OR RISER INTERFACE Distance Wires LINE C m m 200 - - - - - - Used only cable Ref.1083/90 FROM POWER SUPPLY TO DOOR UNIT INTERFACE OR TO RISER INTERFACE Distance BACKBONES Wires LINE m 5 - - - - - - Used only cable Ref.1083/90 FROM DOOR UNIT INTERFACE TO LAST RISER INTERFACE m 200 - - - Distance Wires LINE The maximum distance between the call outd oor station and the most distant ind oor set must be: a) 40 0 m. with or without riser interface. b) 6 00 m. using door unit interface and riser interface. A INDOOR SET IMPORTANT NOTES In a ll cases, to improve interference immu nity, do not arrange the system wires near 230V~ and 400V~ power wires whic h generate strong electromagnetic fields. RISER INTERFACE VV.007 - If door open warning service is needed, the following connection has to be carried out on the call station (for preset devices only). PA CT Lock release SP NC CONTACT = CLOSED DOOR VV.008 - Setting the dip-switch “1” in position OFF. VX.006 - See the instruction book provided with the product for fitting the accessory in the device. VX.008 - Connect the devices to a filter and power line protection device. N 2 2 Ref.1332/86 FILTER 2 LIVE 1 IN 1 OUT 1 IN VX.032 - Minimum wire section. Power supply cords and length (12Vdc) have to be configured according to cameras consumption. See following table: Camera Consumption Wire Section (Sq.mm) max 300mA 0,75 1,5 2,5 4 Wire lenght (m) 50 100 150 240 VX.033 - Minimum wire section. Power supply cords and length (12Vdc) have to be configured according to cameras consumption. See following table: Camera Consumption Wire Section (Sq.mm) 1 2,5 4 Wire lenght (m) 50 125 200 VX.037 - On device setting the jumper/dip-switch "Z" in position ON. 1 OUT VX.021 - Cut or remove the jumpers on the device(s): a) Between pins "Z". max 500mA 2 EARTH L VX.014 - Dusk switch or similar device for switching lights on, where relevant. L N UTILITY 2 VOICE - Technical Manual sec.6 −−−−  INSTALLATION DIAGRAMS CALL STATION Ref.1332/85 PROTECTION NEUTRAL - - Used only cable Ref.1083/90 DEVICES LIST DEVICES LIST To implement diagrams described in this section, the following devices can be used: APARTMENT STATIONS VIDEO DOOR PHONE Signo Model Ref.1740/1.......................... Black/White video door phone (white) Ref.1740/40........................ Colour video door phone (white) Ref.1740/41........................ Colour video door phone (anthracite) Ref.1740/42........................ Colour video door phone (platinum) Ref.1740/83........................ Bracket Accessories Ref.1083/96........................ Add-on buttons unit Folio Model Ref.1706/5.......................... Hands-free colour video door phone (black) Ref.1706/6.......................... Hands-free colour video door phone (white) Accessories Ref.1706/60........................ Embedding box Ref.1706/61........................ Kit for plasterboard installation Aiko Model Ref.1716/1.......................... Hands-free colour video door phone (black) Ref.1716/2.......................... Hands-free colour video door phone (white) Accessories Ref.1716/60........................ Embedding box Ref.1716/51........................ Coloured mask BASIC DOOR PHONE Atlantico Model Ref.1183/1.......................... Door phone with 1 additional button COMFORT DOOR PHONE Signo Model Ref.1183/2.......................... Door phone with 3 additional buttons Ref.1183/3.......................... Door phone with 10 additional buttons concierge switchboard VIDEO DOOR PHONE Ref.1083/40........................ Concierge switchboard Ref.1732/41........................ Colour video module Ref.1732/91........................ Bracket for video module DOOR PHONE Ref.1083/40........................ Concierge switchboard Call station ELECTRIC VIDEO DOOR ENTRANCE PANEL Sinthesi Model Ref.1083/72........................ Camera module and door unit with 2 buttons Ref.1145/11-/12-/13-/14.... Button module Ref.1038/17........................ 16-user expander module INSTALLATION DIAGRAMS Exigo Model Ref.1083/8.......................... Loudspeaking unit Ref.1810/40........................ TV camera unit Ref.1038/17........................ 16-user expander module Ref.1743/xxx o 1721/xxx... Exigo push button panel Mikra Model Ref.1783/1.......................... Push button panel with colour camera Ref.1783/2.......................... Push button panel with b/w camera ELECTRIC DOOR ENTRANCE PANEL Sinthesi Model Ref.1083/7.......................... Door unit module with 2 buttons Ref.1145/11-/12-/13-/14.... Button module Ref.1038/17........................ 16-user expander module Modello Exigo Ref.1083/8.......................... Loudspeaking unit Ref.1038/17........................ 16-user expander module Ref.1143/xxx o 1121/xxx... Exigo push button panel 10 −−−− sec.6 2 VOICE - Technical Manual DEVICES LIST TC CALL MODULE Sinthesi Model Ref.1083/13........................ Call module Accessories Ref.1745/40........................ Colour camera module Ref.1745/70........................ Black/white camera module For other products necessary for call stations installation, see the other sections of the manual. ACCESSORIES Ref.1072/59........................ Additional ringer Ref.9854/40........................ Electronic ringer POWER SUPPLY UNITS, RELAY INTERFACES Ref.1083/20........................ System power supply A A Ref.1083/50........................ Column interface B B Ref.1083/75........................ Door units interface C C Ref.1083/69........................ Video switch D D Ref.1783/69........................ BUS interface for CCTV Ref.788/52.......................... Relay box A A Ref.9000/230...................... Transformer B B Ref.789/2............................ Additional power supply C C Ref.1032/81........................ Timing relay D D Ref.1090/850...................... Additional power supply Ref.1083/55........................ 4-user distributor Ref.1038/69........................ Video switch Ref.788/22.......................... Relay call repeater Ref.1083/90-/92.................. Cable for 2VOICE system Generic transformer INSTALLATION DIAGRAMS 12Vac / 15VA electric lock + + - Ref.1092/300A.................... Transmitter / 1 channel passive receiver Ref.1092/801...................... 1200mA plug power supply 2 VOICE - Technical Manual sec.6 −−−− 11 Call stations replacement in diagrams Sinthesi Video Entrance Panel Sinthesi call module with camera module CAMERA MODULE To following modules ~12 ~0 ~0 ~12 G/T U4 U3 U2 U1 G/T G/T ~12 ~0 ~0 ~12 U4 U3 U2 U1 G/T +TC R1 V3 V5 Max 4 expansions 16 users P8 P9 . . . . P3 P14 P2 P15 P16 P1 C C Output Input 2 LINE To the system T+ TV3 V5 ILA ILA Name tag lighting ~12 ~0 ~0 ~12 G/T U4 U3 U2 U1 G/T G/T ~12 ~0 ~0 ~12 U4 U3 U2 U1 G/T + - 8 P8 P9 . . . . P3 P14 P2 P15 P16 P1 C C Output Input Lock release SP PA CT SE2 SE2 C NC NO SE+ SE- 8 ILL ILL TC TC EXP + - ILA T+ T- Electric lock 2 LINE V3B V5B V3A V5A SP PA CT SE2 SE2 SE+ SE- To the system Lock release Electric lock Exigo Video Entrance Panel Mikra Video Entrance Panel Max 2 expansions 16 users ~0 ~12 Camera module ~ 12 ~ (VX.014) TC SP Electric lock 8 (VX.008) Ref.9000/230 TC SE+ SE- SE2 SE2 ~ LINE ~ To the system Lock release PA PA SP A ~ 2 LINE 8 P8 P9 . . . . P3 P14 P2 P15 P16 P1 C C Output Input EXP T+ T- LINE CT SP PA CT V3 V5 2 To the system Lock release SE+ SE- Electric lock Sinthesi Entrance Panel Sinthesi Call Module Exigo Entrance Panel INSTALLATION DIAGRAMS To following modules ~12 ~0 ~0 ~12 G/T U4 U3 U2 U1 G/T G/T ~12 ~0 ~0 ~12 U4 U3 U2 U1 G/T ~12 ~0 ~0 ~12 G/T Name tag lighting V3 V5 ILA ILA SP PA CT 8 P8 P9 . . . . P3 P14 P2 P15 P16 P1 C C Output Input 8 SE+ SE- Electric lock ~ 12 ~ ~ 8 8 A EXP ~ LINE ~ (VX.008) Ref.9000/230 T+ T- V3 V5 LINE CT SP PA CT 2 To the system Lock release SE+ SE- Electric lock ESP ILA T+ T- (VX.014) SE2 SE2 C NC NO P8 P9 . . . . P3 P14 P2 P15 P16 P1 C C Output Input ~0 ~12 Lock release + - U4 U3 U2 U1 G/T ILL Max 2 expansions 16 users To the system T+ T- P8 P9 . . . . P3 P14 P2 P15 P16 P1 C C Output Input U4 U3 U2 U1 G/T G/T ~12 ~0 ~0 ~12 2 LINE Max 4 expansions 16 users LINE V5 V3 A V5 V3 B SP PA CT SE2 SE+ SE- 2 To the system Lock release Electric lock 12 −−−− sec.6 2 VOICE - Technical Manual Connection of a door phone riser to 1 call station (floor connection in parallel) SC124-0278 BACKBONE 2 LINE SS+ 2 LINE CP CP (VD.007) A (VD.007) 2 2 LINE 2 LINE CP (VD.007) 2 SS+ SS+ S+ SRef.1072/59 (C4.013) TO FOLLOWING DOOR PHONES 2 2 LINE SS+ 2 LINE CP CP (VD.007) A LINE (VD.007) 2 2 2 LINE CP (VD.007) To following modules SS+ S+ S- ~12 ~0 ~0 ~12 G/T U4 U3 U2 U1 G/T G/T ~12 ~0 ~0 ~12 U4 U3 U2 U1 G/T ~12 ~0 ~0 ~12 G/T U4 U3 U2 U1 G/T G/T ~12 ~0 ~0 ~12 Ref.1072/59 (C4.013) 2 P8 P9 . . . . Max 4 P3 P14 expansions P2 P15 16 users P16 P1 (VX.006) C C Output Input Name tag lighting ~ P8 P9 . . . . P3 P14 P2 P15 P16 P1 C C Output Input U4 U3 U2 U1 G/T 8 ~ (VX.014) A Ref.9000/230 (VX.008) LINE ~ 8 ILL ESP LINE 2 ILA T+ T- ~12 ~0 INSTALLATION DIAGRAMS Name tag lighting SS+ 2 LINE V5 V3 A V5 V3 PA CT B SP SE2 SE+ SE- Lock release LINE 1 LINE ~ (VV.007) Ref.1083/20 (VX.008) 230 0 DIAGRAM NOTES C4.013 VD.007 VV.002 2 VOICE - Technical Manual VV.007 VV.009 VX.006 VX.008 VX.014 sec.6 −−−− 13 Connection of a column with 4 door phone risers max to 2 call stations (floor connection in parallel) SC124-0280 RISER BACKBONE “1” 2 LINE SS+ 2 LINE CP CP (VD.007) A (VD.007) 2 2 LINE 2 LINE CP (VD.007) 2 SS+ SS+ S+ SRef.1072/59 (C4.013) TO FOLLOWING DOOR PHONES 2 2 LINE SS+ 2 LINE CP CP (VD.007) A (VD.007) 2 2 LINE 2 LINE CP (VD.007) SS+ S+ S- To following modules 2 ~12 ~0 ~0 ~12 G/T U4 U3 U2 U1 G/T G/T ~12 ~0 ~0 ~12 U4 U3 U2 U1 G/T ~12 ~0 ~0 ~12 G/T U4 U3 U2 U1 G/T G/T ~12 ~0 ~0 ~12 Name tag lighting SS+ Ref.1072/59 (C4.013) BACKBONE “2” P8 P9 . . Max 4 . . P3 P14 expansions P2 P15 16 users P16 P1 (VX.006) C C Output Input BACKBONE “3” EQUIPMENT/CONNECTIONS BACKBONES “2-3-4” AS BACKBONE “1” 2 P8 P9 . . . . P3 P14 P2 P15 P16 P1 C C Output Input U4 U3 U2 U1 G/T 2 LINE 2 LINE 3 LINE 1 LINE 4 ESP Z ILA T+ T- 2 8 8 ILL "A" BACKBONE “4” LINE V5 V3 A V5 V3 PA CT B SP SE2 SE+ SE- IN 0 Lock release Ref.1083/50 LINE OUT IN 1 (VV.007) A LINE IN POWER AUX 2 INSTALLATION DIAGRAMS 2 LINE 1 LINE 2 EQUIPMENT/CONNECTIONS AS OUTDOOR STATION “A” LINE ~ Ref.1083/20 (VX.008) 230 0 "B" Name tag lighting ~ 12 ~ ~ ~ (VX.014) (VX.008) LINE ~ DIAGRAM NOTES C4.013 VD.007 VV.002 14 −−−− sec.6 VV.007 VV.009 VX.006 VX.008 VX.014 2 VOICE - Technical Manual Connection of a column with 4 door phone risers max. to 4 call stations (floor connection in parallel) SC124-0281A RISER BACKBONE “1” 2 LINE SS+ BACKBONE “2” 2 CP A 2 2 LINE (VD.007) 2 SS+ LINE CP 2 BACKBONE “4” LINE CP (VD.007) BACKBONE “3” (VD.007) SS+ S+ S- TO FOLLOWING DOOR PHONES Ref.1072/59 (C4.013) 2 2 LINE SS+ 2 CP LINE CP (VD.007) A 2 2 LINE (VD.007) SS+ EQUIPMENT/CONNECTIONS BACKBONES “2-3-4” AS BACKBONE “1” 2 LINE CP (VD.007) SS+ S+ SRef.1072/59 (C4.013) 2 2 2 2 B Ref.1083/75 LINE 2 LINE 3 LINE 1 LINE 4 IN 0 To following modules IN 3 IN 1 ~12 ~0 ~0 ~12 G/T U4 U3 U2 U1 G/T G/T ~12 ~0 ~0 ~12 2 P8 P9 . . . . P3 P14 P2 P15 P16 P1 C C Output Input U4 U3 U2 U1 G/T IN 2 POWER LINE POWER IN 2 Max 4 expansions 16 users LINE 1 (VX.006) Ref.1083/20 (VX.008) LINE 2 2 Name tag lighting "A" ~12 ~0 ~0 ~12 G/T U4 U3 U2 U1 G/T G/T ~12 ~0 ~0 ~12 U4 U3 U2 U1 G/T LINE ~ 0 P8 P9 . . . . P3 P14 P2 P15 P16 P1 C C Output Input 8 LINE 1 2 LINE 2 LINE ~ 8 ILL 230 2 Ref.1083/20 (VX.008) 2 230 0 ESP ILA T+ T- Name tag lighting LINE V5 V3 A V5 V3 B SP SE2 SE+ SE- PA CT (VV.007) ~ 12 ~ ~ Lock release (VX.014) ~ (VX.008) LINE ~ A Ref.788/52 2 12~ S2 S1 S3 CA 0~ 6 EQUIPMENT/CONNECTIONS AS OUTDOOR STATION “A” Ref.9000/230 ~0 ~12 230 additional lock release EQUIPMENT/CONNECTIONS AS OUTDOOR STATION “A” EQUIPMENT/CONNECTIONS AS OUTDOOR STATION “A” "C" "D" LINE~ 0 "B" (VX.008) ADDITIONAL ELECTRIC LOCK DIAGRAM NOTES C4.013 VD.007 VV.002 2 VOICE - Technical Manual VV.007 VV.009 VX.006 VX.008 VX.014 sec.6 −−−− 15 INSTALLATION DIAGRAMS EXAMPLE Connection of 16 columns max. with door phones to 1 main call station Each group is connected to 1 or 2 secondary call stations (floor connection in parallel) SC124-0296 RISER BACKBONE “1” BACKBONE “2” TO FOLLOWING DOOR PHONES BACKBONE “3” BACKBONE “4” Ref. EQUIPMENT/CONNECTIONS BACKBONES “2-3-4” AS BACKBONE “1” Ref. Ref. EQUIPMENT/CONNECTIONS AS MAIN OUTDOOR STATION “A” EQUIPMENT/CONNECTIONS AS MAIN OUTDOOR STATION “A” EQ Ref. Name tag lighting SECONDARY SECONDARY To following modules Max 4 expansions 16 users INSTALLATION DIAGRAMS Name tag lighting Ref. Lock release MAIN Name tag lighting DIAGRAM NOTES C4.013 VD.007 VV.002 16 −−−− sec.6 VV.004 VV.006 VV.007 VV.008 VV.009 VX.006 VX.008 VX.014 VX.021 2 VOICE - Technical Manual Connection of 16 columns max. with door phones to 1 main call station Each group is connected to 1 or 2 secondary call stations (floor connection in parallel) SC124-0296 RISER “4” BACKBONE “5” BACKBONE “6” BACKBONE “7” EQUIPMENT/CONNECTIONS BACKBONES “5-6” AS BACKBONE “1” BACKBONE “8” EQUIPMENT/CONNECTIONS BACKBONES “7-8” AS BACKBONE “1” Ref. TO THE FOLLOWING INTERFACES EQUIPMENT/CONNECTIONS AS MAIN OUTDOOR STATION “A” EQUIPMENT/CONNECTIONS AS MAIN OUTDOOR STATION “A” Ref. Name tag lighting SECONDARY INSTALLATION DIAGRAMS SECONDARY 2 VOICE - Technical Manual sec.6 −−−− 17 Connection of N columns with door phones to 4 main call stations max. Each group is connected to 1 or 2 secondary call stations (floor connection in parallel) SC124-0282A RISER 1 BACKBONE “1” 2 LINE SS+ BACKBONE “2” 2 CP A (VD.007) 2 2 LINE 2 SS+ LINE CP (VD.007) 2 BACKBONE “4” LINE CP (VD.007) BACKBONE “3” SS+ S+ S- TO FOLLOWING DOOR PHONES Ref.1072/59 (C4.013) 2 2 LINE SS+ 2 LINE CP CP (VD.007) A (VD.007) 2 2 LINE 2 SS+ EQUIPMENT/CONNECTIONS BACKBONES “2-3-4” AS BACKBONE “1” 2 LINE CP (VD.007) 2 S+ S- 2 2 SS+ A Ref.1083/50 Ref.1072/59 (C4.013) 2 LINE 2 LINE 3 LINE 1 LINE 4 IN 0 IN 1 LINE IN EQUIPMENT/CONNECTIONS AS MAIN OUTDOOR STATION “A” LINE OUT POWER EQUIPMENT/CONNECTIONS AS MAIN OUTDOOR STATION “A” AUX 2 LINE 1 LINE 2 "I" "II" SECONDARY Ref.1083/20 (VX.008) 230 LINE ~ SECONDARY (VX.021) (VV.008) Z 2 0 Name tag lighting ~ 12 ~ 2 ~ ~ (VX.014) (VX.008) LINE ~ To following modules Name tag lighting 2 ~12 ~0 ~0 ~12 G/T U4 U3 U2 U1 G/T G/T ~12 ~0 ~0 ~12 U4 U3 U2 U1 G/T ~12 ~0 ~0 ~12 G/T U4 U3 U2 U1 G/T G/T ~12 ~0 ~0 ~12 U4 U3 U2 U1 G/T P8 P9 . . . . P3 P14 P2 P15 P16 P1 C C Output Input Max 4 expansions 16 users (VX.006) 8 B Ref.1083/75 8 ILL ESP "A" ILA T+ T- MAIN INSTALLATION DIAGRAMS P8 P9 . . . . P3 P14 P2 P15 P16 P1 C C Output Input 2 LINE V5 V3 A V5 V3 B PA CT SP SE2 SE+ SE- (VV.007) 2 12~ S2 S1 S3 CA 0~ 6 LINE 4 IN 3 IN 1 IN 2 POWER LINE 2 POWER IN 2 LINE 1 2 EQUIPMENT/CONNECTIONS AS MAIN OUTDOOR STATION “A” A Ref.788/52 LINE 3 LINE 1 IN 0 Lock release EXAMPLE LINE 2 Ref.1083/20 (VX.008) EQ LINE 2 230 LINE ~ 0 Ref.9000/230 ~0 ~12 230 0 additional lock release LINE 1 LINE~ LINE 2 "B" (VX.008) LINE ~ ADDITIONAL ELECTRIC LOCK Ref.1083/20 (VX.008) 230 0 MAIN Name tag lighting ~ 12 ~ ~ (b) ~ (VX.014) (VX.008) LINE ~ DIAGRAM NOTES C4.013 VD.007 VV.002 18 −−−− sec.6 VV.003 VV.004 VV.007 VV.008 VV.009 VX.006 VX.008 VX.014 VX.021 2 VOICE - Technical Manual Connection of N columns with door phones to 4 main call stations max. Each group is connected to 1 or 2 secondary call stations (floor connection in parallel) SC124-0282A RISER 2 E “4” BACKBONE “5” BACKBONE “6” BACKBONE “7” EQUIPMENT/CONNECTIONS BACKBONES “5-6” AS BACKBONE “1” 2 EQUIPMENT/CONNECTIONS BACKBONES “7-8” AS BACKBONE “1” 2 2 A 2 BACKBONE “8” 2 Ref.1083/50 LINE 2 LINE 3 LINE 1 LINE 4 IN 0 Z 2 IN 1 LINE IN EQUIPMENT/CONNECTIONS AS MAIN OUTDOOR STATION “A” LINE 1 "IV" LINE ~ SECONDARY TO THE FOLLOWING INTERFACES AUX 2 LINE 2 "III" 2 LINE OUT POWER EQUIPMENT/CONNECTIONS AS MAIN OUTDOOR STATION “A” (VX.021) (VV.004) (VV.008) SECONDARY 2 Ref.1083/20 (VX.008) 230 0 Name tag lighting ~ 12 ~ ~ ~ (VX.014) (VX.008) LINE ~ EQUIPMENT/CONNECTIONS AS MAIN OUTDOOR STATION “A” "C" 2 INSTALLATION DIAGRAMS 2 EQUIPMENT/CONNECTIONS AS MAIN OUTDOOR STATION “A” "D" MAIN 2 VOICE - Technical Manual MAIN sec.6 −−−− 19 Connection of a riser with video door phones and door phones to 1 call station (floor connetions with 4-user distributor) SV124-0954B BACKBONE Ref.1083/55 Ref.1072/59 TO FOLLOWING DISTRIBUTORS Ref.1083/55 Ref.1072/59 To following modules Max 4 expansions 16 users INSTALLATION DIAGRAMS Name tag lighting Ref.1083/20 Lock release Name tag lighting Ref.9000/230 DIAGRAM NOTES C4.013 VD.007 VV.001 20 −−−− sec.6 VV.002 VV.007 VX.006 VX.008 VX.014 VX.037 2 VOICE - Technical Manual CONNECTION OF A COLUMN WITH 4 VIDEO DOOR PHONES/DOOR PHONES RISERS TO 2 Call stations (floor connetions with 4-user distributor) INSTALLATION DIAGRAMS SV124-0955B DIAGRAM NOTES C4.013 VD.007 VV.001 2 VOICE - Technical Manual VV.002 VV.007 VX.006 VX.008 VX.014 VX.037 sec.6 −−−− 21 CONNECTION OF 1 COLUMN WITH VIDEO DOOR PHONES AND DOOR PHONES TO 4 MAIN Call stations MAX. INSTALLATION DIAGRAMS SV124-0997B 22 −−−− sec.6 2 VOICE - Technical Manual CONNECTION OF 1 COLUMN WITH VIDEO DOOR PHONES AND DOOR PHONES TO 4 MAIN Call stations MAX. INSTALLATION DIAGRAMS SV124-0997B DIAGRAM NOTES C4.013 VD.007 VV.001 2 VOICE - Technical Manual VV.002 VV.007 VX.006 VX.008 VX.014 VX.037 sec.6 −−−− 23 CONNECTION OF N COLUMNS WITH VIDEO DOOR PHONES AND DOOR PHONES, TO 1 MAIN Call station (Video call station). Each column is connected to 1 or 2 secondary video call stations. INSTALLATION DIAGRAMS SV124-0962B 24 −−−− sec.6 2 VOICE - Technical Manual CONNECTION OF N COLUMNS WITH VIDEO DOOR PHONES AND DOOR PHONES, TO 1 MAIN Call station (Video call station). Each column is connected to 1 or 2 secondary video call stations. INSTALLATION DIAGRAMS SV124-0962B DIAGRAM NOTES C4.013 VD.007 VV.001 2 VOICE - Technical Manual VV.002 VV.004 VV.006 VV.007 VV.008 VX.006 VX.008 VX.014 VX.021 VX.037 sec.6 −−−− 25 Connection of N columns with video door phones and door phones to 4 main call stations max. Each column is connected to 1 or 2 secondary video call stations. SV124-0963C RISER BACKBONE “1” Ref.1083/55 Ref.1072/59 TO FOLLOWING DISTRIBUTORS Ref.1083/55 Ref.1072/59 BACKBONE “2” BACKBONE “3” BACKBONE “4” EQUIPMENT/CONNECTIONS BACKBONES “2-3-4” AS BACKBONE “1” Ref.1083/50 EQUIPMENT/CONNECTIONS AS MAIN VIDEO OUTDOOR STATION “A” EQUIPMENT/CONNECTIONS AS MAIN VIDEO OUTDOOR STATION “A” Ref.1083/20 Name tag lighting SECONDARY SECONDARY Ref.1083/75 EQUIPMENT/CONNECTIONS AS LINE1 To following modules INSTALLATION DIAGRAMS Max 4 expansions 16 users Ref.1083/20 EQUIPMENT/CONNECTIONS AS MAIN VIDEO OUTDOOR STATION “A” Name tag lighting Ref.1083/20 Name tag lighting Lock release MAIN MAIN DIAGRAM NOTES C4.013 VD.007 VV.001 26 −−−− sec.6 VV.002 VV.003 VV.004 VV.007 VV.008 VX.006 VX.008 VX.014 VX.021 VX.037 2 VOICE - Technical Manual Connection of N columns with video door phones and door phones to 4 main call stations max. Each column is connected to 1 or 2 secondary video call stations. SV124-0963C BACKBONE “5” BACKBONE “6” BACKBONE “7” BACKBONE “8” EQUIPMENT/CONNECTIONS BACKBONES “5-6-7-8” AS BACKBONE “1” Ref.1083/50 TO THE FOLLOWING INTERFACES EQUIPMENT/CONNECTIONS AS MAIN VIDEO OUTDOOR STATION “A” EQUIPMENT/CONNECTIONS AS MAIN VIDEO OUTDOOR STATION “A” Ref.1083/20 Name tag lighting SECONDARY SECONDARY EQUIPMENT/CONNECTIONS AS MAIN VIDEO OUTDOOR STATION “A” EQUIPMENT/CONNECTIONS AS MAIN VIDEO OUTDOOR STATION “A” MAIN MAIN 2 VOICE - Technical Manual INSTALLATION DIAGRAMS ECTIONS sec.6 −−−− 27 Connection of a riser with video door phones and door phones to 1 switchboard and 1 call station SV124-1098 To following modules SUPPLIED SWITCHBOARD WIRING JUNCTION BOX (Black) Max 4 expansions 16 users (Red) INSTALLATION DIAGRAMS Name tag lighting Lock release Name tag lighting DIAGRAM NOTES C4.013 VD.007 VV.001 VV.002 VV.007 VX.006 VX.008 VX.014 VX.037 VV.010 - Parameters configuration Switchboard: - System in column: 1 (YES). - Associated monitor: 1 (YES). 28 −−−− sec.6 2 VOICE - Technical Manual Connection of a column with 4 risers max. of video door phones and door phones to 1 switchboard and 4 call stations RISER BACKBONE “1” SV124-1155 Ref.1083/55 Ref.1072/59 TO FOLLOWING DISTRIBUTORS Ref.1083/55 Ref.1072/59 BACKBONE “2” BACKBONE “3” BACKBONE “4” EQUIPMENT/CONNECTIONS BACKBONES “2-3-4” AS BACKBONE “1” Ref.1083/55 To following modules SUPPLIED SWITCHBOARD WIRING JUNCTION BOX Max 4 expansions 16 users Ref.1083/40 Ref.1732/41 (Black) (Red) Ref.1083/20 Name tag lighting Ref.1083/50 EQUIPMENT/CONNECTIONS AS MAIN VIDEO OUTDOOR STATION “A” INSTALLATION DIAGRAMS Lock release Ref.1083/20 Name tag lighting DIAGRAM NOTES C4.013 VD.007 VV.001 VV.002 VV.007 VX.006 VX.008 VX.014 VX.037 VV.010 - Parameters configuration Switchboard: - System in column: 1 (YES). - Associated monitor: 1 (YES). 2 VOICE - Technical Manual sec.6 −−−− 29 CONNECTION OF A RISER WITH VIDEO DOOR PHONES AND DOOR PHONES TO 1 SWITCHBOARD AND TO 4 MAIN CALL STATIONS MAX SV124-1156 RISER BACKBONE “1” BA Ref.1083/55 Ref.1072/59 TO FOLLOWING DISTRIBUTORS Ref.1083/55 Ref.1072/59 To following modules Max 4 expansions 16 users EQUIPMENT/CONNECTIONS AS VIDEO OUTDOOR STATION “A” INSTALLATION DIAGRAMS Name tag lighting Lock release 30 −−−− sec.6 2 VOICE - Technical Manual CONNECTION OF A RISER WITH VIDEO DOOR PHONES AND DOOR PHONES TO 1 SWITCHBOARD AND TO 4 MAIN CALL STATIONS MAX SV124-1156 SER BACKBONE “2” BACKBONE “3” BACKBONE “4” EQUIPMENT/CONNECTIONS BACKBONES “2-3-4” AS BACKBONE “1” SUPPLIED SWITCHBOARD WIRING JUNCTION BOX Ref.1083/40 Ref.1732/41 (Black) (Red) Ref.1083/55 B Ref.1083/75 Ref.1083/20 EQUIPMENT/CONNECTIONS AS VIDEO OUTDOOR STATION “A” Ref.1083/20 EQUIPMENT/CONNECTIONS AS VIDEO OUTDOOR STATION “A” INSTALLATION DIAGRAMS Ref.1083/20 Name tag lighting DIAGRAM NOTES C4.013 VD.007 VV.001 VV.002 VV.007 VX.006 VX.008 VX.014 VX.037 VV.010 - Parameters configuration Switchboard: - System in column: 1 (YES). - Associated monitor: 1 (YES). 2 VOICE - Technical Manual sec.6 −−−− 31 Connection of 16 columns max. with video door phones and door phones to 1 switchboard and 1 main call station (each column is connected to 1 or 2 secondary call stations) SV124-1100A RISER 1 BACKBONE “1” Ref.1083/55 Ref.1072/59 TO FOLLOWING DISTRIBUTORS Ref.1083/55 Ref.1072/59 BACKBONE “2” BACKBONE “3” BACKBONE “4” EQUIPMENT/CONNECTIONS BACKBONES “2-3-4” AS BACKBONE “1” Ref.1083/50 EQUIPMENT/CONNECTIONS AS MAIN VIDEO OUTDOOR STATION “A” EQUIPMENT/CONNECTIONS AS MAIN VIDEO OUTDOOR STATION “A” EQ AS Ref.1083/20 Name tag lighting SECONDARY SECONDARY Ref.1083/40 SUPPLIED SWITCHBOARD WIRING JUNCTION BOX To following modules Ref.1732/41 (Black) (Red) INSTALLATION DIAGRAMS Max 4 expansions 16 users Ref.1083/55 Ref.1083/20 Name tag lighting Ref.1083/20 Lock release Name tag lighting A Ref.9000/230 MAIN 32 −−−− sec.6 2 VOICE - Technical Manual Connection of 16 columns max. with video door phones and door phones to 1 switchboard and 1 main call station (each column is connected to 1 or 2 secondary call stations) SV124-1100A RISER 2 BACKBONE “4” BACKBONE “5” “2-3-4” BACKBONE “6” BACKBONE “7” BACKBONE “8” EQUIPMENT/CONNECTIONS BACKBONES “5-6-7-8” AS BACKBONE “1” Ref.1083/50 TO FOLLOWING INTERFACES EQUIPMENT/CONNECTIONS AS MAIN VIDEO OUTDOOR STATION EQUIPMENT/CONNECTIONS AS MAIN VIDEO OUTDOOR STATION Ref.1083/20 Name tag lighting SECONDARY SECONDARY Ref.1732/41 (Black) INSTALLATION DIAGRAMS (Red) DIAGRAM NOTES C4.013 VD.007 VV.001 VV.002 VV.004 VV.006 VV.007 VV.008 VX.006 VX.008 VX.014 VX.021 VX.037 VV.010 - Parameters configuration Switchboard: - System in column: 0 (NO). - Associated monitor: 1 (YES). 2 VOICE - Technical Manual sec.6 −−−− 33 Connection of N columns with video door phones and door phones to 1 switchboard and 4 main call stations max. (each column is connected to 1 or 2 secondary call stations) RISER 1 SV124-1099A BACKBONE “1” Ref.1083/55 Ref.1072/59 TO FOLLOWING DISTRIBUTORS BACKBONE “2” BACKBONE “3” BACKBONE “4” EQUIPMENT/CONNECTIONS BACKBONES “2-3-4” AS BACKBONE “1” Ref.1083/55 Ref.1083/50 Ref.1072/59 EQUIPMENT/CONNECTIONS AS MAIN VIDEO OUTDOOR STATION “A” EQUIPMENT/CONNECTIONS AS MAIN VIDEO OUTDOOR STATION “A” Ref.1083/20 SECONDARY SECONDARY SUPPLIED SWITCHBOARD WIRING JUNCTION BOX Ref.1083/40 Ref.1732/41 Name tag lighting Ref.1083/55 Ref.1083/20 Ref.1083/75 To following modules Max 4 expansions 16 users INSTALLATION DIAGRAMS Ref.1083/20 EQUIPMENT/CONNECTIONS AS MAIN VIDEO OUTDOOR STATION “A” Name tag lighting Ref.1083/20 Name tag lighting Lock release MAIN MAIN DIAGRAM NOTES C4.013 VD.007 VV.001 VV.002 VV.003 VV.004 VV.007 VV.008 VX.006 VX.008 VX.014 VX.021 VX.037 VV.010 - Parameters configuration Switchboard: - System in column: 0 (NO). - Associated monitor: 1 (YES). 34 −−−− sec.6 2 VOICE - Technical Manual Connection of N columns with video door phones and door phones to 1 switchboard and 4 main call stations max. (each column is connected to 1 or 2 secondary call stations) RISER 2 ACKBONE “4” BACKBONE “5” 2-3-4” SV124-1099A BACKBONE “6” BACKBONE “7” BACKBONE “8” EQUIPMENT/CONNECTIONS BACKBONES “5-6-7-8” AS BACKBONE “1” Ref.1083/50 TO FOLLOWING INTERFACES EQUIPMENT/CONNECTIONS AS MAIN VIDEO OUTDOOR STATION “A” EQUIPMENT/CONNECTIONS AS MAIN VIDEO OUTDOOR STATION “A” Ref.1083/20 Name tag lighting SECONDARY SECONDARY EQUIPMENT/CONNECTIONS AS MAIN VIDEO OUTDOOR STATION “A” EQUIPMENT/CONNECTIONS AS MAIN VIDEO OUTDOOR STATION “A” MAIN MAIN 2 VOICE - Technical Manual INSTALLATION DIAGRAMS .1732/41 sec.6 −−−− 35 Connection of a door phone riser to 1 switchboard and 1 call station (floor connection in parallel) BACKBONE SC124-0307 Ref.1072/59 TO FOLLOWING DOOR PHONES Ref.1072/59 TO FOLLOWING MODULES SUPPLIED SWITCHBOARD WIRING JUNCTION BOX Max 4 expansions 16 users Ref.1083/55 Ref.1083/20 INSTALLATION DIAGRAMS Name tag lighting Ref.1083/20 Lock release Name tag lighting Ref.9000/230 DIAGRAM NOTES C4.013 VD.007 VV.002 VV.007 VV.009 VX.006 VX.008 VX.014 VV.010 - Parameters configuration Switchboard: - System in column: 1 (YES). - Associated monitor: 0 (NO). 36 −−−− sec.6 2 VOICE - Technical Manual Connection to a call station with: A1) 2 control cameras B1) 5 control cameras SV124-1020A EXAMPLE A1) TO THE SYSTEM Max 4 expansions 16 users Name tag lighting Lock release Or CONTROL STATION EXAMPLE B1) TO THE SYSTEM Max 4 expansions 16 users B Power supply Ref.789/2 Name tag lighting SWITCHING DEVICE Ref.1038/69 Lock release Or INSTALLATION DIAGRAMS CONTROL STATION Or DIAGRAM NOTES VD.001 VV.002 VX.006 2 VOICE - Technical Manual VX.008 VX.032 VX.033 TV.001 TV.008 sec.6 −−−− 37 Connection to a call station with: A2) 2 control cameras B2) 5 control cameras SV124-1020A EXAMPLE A2) TO THE SYSTEM TO THE SYSTEM x 4 nsions users Camera module Red Black Lock release TO THE SYSTEM EXAMPLE B2) B x 4 nsions users Power supply Ref.789/2 TO THE SYSTEM Red Black Camera module SWITCHING DEVICE Ref.1038/69 Or CONTROL STATION INSTALLATION DIAGRAMS Lock release Or DIAGRAM NOTES VD.001 VV.002 38 −−−− sec.6 VX.006 VX.008 VX.032 VX.033 TV.001 TV.008 2 VOICE - Technical Manual Call repeat examples A) C) D) Without timing B) With timing from 1 to 30s SV124-1024 Ref.1072/59 C A Ref.9000/230 Ref.1032/81 Ref.9854/40 Ref.9000/230 A LOAD MAINS INSTALLATION DIAGRAMS Ref.788/52 Ref.1090/850 D LOAD MAINS Ref.788/22 DIAGRAM NOTES C4.013 VD.007 VX.008 2 VOICE - Technical Manual sec.6 −−−− 39 Examples of switchboard call repeat: A) With additional ringer Ref. 1072/59 B) With electronic ringer Ref. 9854/40 and timing from 1 to 30s SV124-1118 FROM: SUPPLIED SWITCHBOARD WIRING JUNCTION BOX Ref.1083/40 - 4 USERS DISTRIBUTOR Ref.1083/55 - COLUMN INTERFACE Ref.1083/50 - DOOR UNITS INTERFACE Ref.1083/75 FROM: - 4 USERS DISTRIBUTOR Ref.1083/55 - COLUMN INTERFACE Ref.1083/50 - DOOR UNITS INTERFACE Ref.1083/75 Ref.1732/41 FROM: - 4 U Ref - COL Ref - DOO Ref (Black) (Red) Ref.1072/59 SUPPLIED SWITCHBOARD Ref.1083/40 Ref.1732/41 WIRING JUNCTION BOX Ref.1083/20 (Black) FROM - 4 Re - CO Re - DO Re (Red) Ref.1072/59 Ref.1083/20 INSTALLATION DIAGRAMS FROM: - 4 USERS DISTRIBUTOR Ref.1083/55 - COLUMN INTERFACE Ref.1083/50 - DOOR UNITS INTERFACE Ref.1083/75 FROM: - 4 USERS DISTRIBUTOR Ref.1083/55 - COLUMN INTERFACE Ref.1083/50 - DOOR UNITS INTERFACE Ref.1083/75 SUPPLIED SWITCHBOARD WIRING JUNCTION BOX Ref.1083/40 Ref.1732/41 (Black) (Red) SUPPLIED SWITCHBOARD Ref.1083/40 WIRING JUNCTION BOX Ref.1083/20 Ref.1732/41 C (Black) A (Red) Ref.9000/230 DIAGRAM NOTES C4.013 VX.008 VV.010 - Parameters configuration Switchboard: - Associated monitor: 1 (YES). 40 −−−− sec.6 FROM: - 4 U Ref - COL Ref - DOO Ref Ref.1032/81 Ref.9854/40 C Ref.1083/20 A Ref.9000/230 Ref.1032/81 Ref.9854/40 2 VOICE - Technical Manual FROM - 4 Re - CO Re - DO Re Examples of switchboard call repeat: C) With 5A/100Vdc max. load with relay box Ref. 788/52 D) With 1A/24Vdc max. load with relay box Ref. 788/52 SV124-1118 FROM: - 4 USERS DISTRIBUTOR Ref.1083/55 - COLUMN INTERFACE Ref.1083/50 - DOOR UNITS INTERFACE Ref.1083/75 FROM: - 4 USERS DISTRIBUTOR Ref.1083/55 - COLUMN INTERFACE Ref.1083/50 - DOOR UNITS INTERFACE Ref.1083/75 SUPPLIED SWITCHBOARD WIRING JUNCTION BOX Ref.1083/40 Ref.1732/41 (Black) (Red) SUPPLIED SWITCHBOARD WIRING JUNCTION BOX Ref.1083/40 Ref.1732/41 (Black) Ref.9000/230 (Red) A LOAD Ref.1083/20 MAINS Ref.9000/230 Ref.788/52 A LOAD Ref.1083/20 MAINS Ref.788/52 FROM: - 4 USERS DISTRIBUTOR Ref.1083/55 - COLUMN INTERFACE Ref.1083/50 - DOOR UNITS INTERFACE Ref.1083/75 SUPPLIED SWITCHBOARD WIRING JUNCTION BOX Ref.1083/40 Ref.1732/41 SUPPLIED SWITCHBOARD WIRING JUNCTION BOX Ref.1083/40 Ref.1732/41 Ref.1090/850 D Ref.1083/20 LOAD Ref.1090/850 9854/40 Ref.788/22 Ref.1083/20 D MAINS LOAD MAINS 9854/40 Ref.788/22 DIAGRAM NOTES C4.013 VX.008 VV.010 - Parameters configuration Switchboard: - Associated monitor: 1 (YES). 2 VOICE - Technical Manual sec.6 −−−− 41 INSTALLATION DIAGRAMS FROM: - 4 USERS DISTRIBUTOR Ref.1083/55 - COLUMN INTERFACE Ref.1083/50 - DOOR UNITS INTERFACE Ref.1083/75 Relay connection to a call station to activate an additional electric lock SV124-1026A EXAMPLE A1 EXAMPLE A2 TO THE SYSTEM TO THE SYSTEM To following modules Max 4 expansions 16 users Max 4 expansions 16 users Name tag lighting Name tag lighting Lock release System lock release Additional lock release ADDITIONAL ELECTRIC LOCK ADDITIONAL ELECTRIC LOCK Additional lock release SYSTEM ELECTRIC LOCK SYSTEM ELECTRIC LOCK Ref.788/52 Ref.788/52 Ref.9000/230 Ref.9000/230 EXAMPLE B1 EXAMPLE B2 TO THE SYSTEM TO THE SYSTEM Red Black INSTALLATION DIAGRAMS Lock release SYSTEM ELECTRIC LOCK ADDITIONAL ELECTRIC LOCK Lock release Additional lock release SYSTEM ELECTRIC LOCK ADDITIONAL ELECTRIC LOCK Additional lock release Ref.788/52 Ref.788/52 Ref.9000/230 Ref.9000/230 DIAGRAM NOTES VV.002 VX.006 42 −−−− sec.6 VX.008 2 VOICE - Technical Manual Connection of an additional electric lock A) Activation in parallel with the system one B) Manual activation independent (button) SV124-1029A EXAMPLE A) TO THE SYSTEM Lock release SYSTEM ELECTRIC LOCK ADDITIONAL ELECTRIC LOCK Ref.9000/230 Ref.788/52 Ref.9000/230 EXAMPLE B) TO THE SYSTEM SYSTEM ELECTRIC LOCK ADDITIONAL ELECTRIC LOCK Ref.9000/230 Ref.788/52 Ref.9000/230 Additional lock release DIAGRAM NOTES VV.002 VX.008 2 VOICE - Technical Manual sec.6 −−−− 43 INSTALLATION DIAGRAMS System lock release Connection of 5 control cameras to one call station SV124-1089A TO FOLLOWING MODULES Max 4 expansions 16 users Ref.789/2 Name tag lighting C Ref.1083/69 TO THE SYSTEM Lock release Or CONTROL STATION A Name tag lighting Ref.9000/230 INSTALLATION DIAGRAMS Or DIAGRAM NOTES VD.017 VV.001 44 −−−− sec.6 VV.002 VV.007 VX.006 VX.008 VX.014 VX.032 VX.033 TV.001 TV.008 2 VOICE - Technical Manual Connection of 5 control cameras to one call station SV124-1113 To the next distributors or to IN0 - IN1 terminal pins of a column interface Ref.1083/50 D (Black cable) (B/W cable) INSTALLATION DIAGRAMS From door units interface or from column interface or from power supply DIAGRAM NOTES VX.008 VX.032 VX.033 2 VOICE - Technical Manual TV.031 sec.6 −−−− 45 Special decoder connection and programming with connection derived by the distributor SV124-1157 RISER “0” BACKBONE “1” BACKBONE 2 as BACKBONE 1 RISER “1” BACKBONE 3 as BACKBONE 1 BACKBONE 4 as BACKBONE 1 BACKBONE “1” BACKBONE “2” BACKBONE 3 as BACKBONE 2 BACKBONE 4 as BACKBONE 2 BLOCK A USER 0 SECONDARY SECONDARY MAIN 2 VOICE CABLE INSTALLATION DIAGRAMS 2(a) = 2 VOICE CABLE (+2 WIRES AND DEDICATED TRANSFORMER (b) IN THE NUMBER OF NAME TAGS IS GREATER THAN 32) DIAGRAM NOTES V5.006 VD.007 VX.008 46 −−−− sec.6 VX.021 2 VOICE - Technical Manual Special decoder connection and programming with connection derived by the distributor SV124-1157 BLOCCO A TO FOLLOWING DISTRIBUTORS FROM COLUMN INTERFACE LOAD SPECIAL DECODER INSTALLATION DIAGRAMS USER 4 2 VOICE - Technical Manual sec.6 −−−− 47 Special decoder connection and programming with connection derived by the distributor SV124-1157 RISER “0” BACKBONE “1” BACKBONE 2 as BACKBONE 1 RISER “1” BACKBONE 3 as BACKBONE 1 DORSALE "1" BACKBONE 4 as BACKBONE 1 BACKBONE 2 as BACKBONE 1 BACKBONE 3 as BACKBONE 1 BACKBONE 4 as BACKBONE 1 USER 0 USER 4 BLOCK B 2 VOICE CABLE 2(a) = 2 VOICE CABLE (+2 WIRES AND DEDICATED TRANSFORMER (b) IN THE NUMBER OF NAME TAGS IS GREATER THAN 32) MAIN 2 INSTALLATION DIAGRAMS MAIN 1 48 −−−− sec.6 2 VOICE - Technical Manual Special decoder connection and programming with connection between door units interface and column interface SV124-1157 BLOCK B TO COLUMN INTERFACES DOOR UNIT INTERFACE TO THE SWITCHBOARD TO MAIN VIDEO OUTDOOR STATION SPECIAL DECODER MAX No. 2 LOAD POWER SUPPLY INSTALLATION DIAGRAMS POWER SUPPLY DIAGRAM NOTES V5.006 VD.007 VX.008 2 VOICE - Technical Manual sec.6 −−−− 49 Special decoder connection and programming with connection between door units interface and column interface SV124-1157 STANDARD PROGRAMMING (EXAMPLES) Example 1: activation of special decoder after pressing the pedestrian door lock release button of any system user. Example 2: activation of special decoder after pressing the driveway door lock relese button of any system user in riser 1. VV.016 - Special service decoder must be configured as follows: VV.016 - Special service decoder must be configured as follows: VV.016 - Special service decoder must be configured as follows: Program the event: Program the event: Program the event: 1)press the pedestrian door lock release button from apartment station (default) 2) press the driveway door lock release button from apartment station 3) press the call button to switchboard from apartment station 4) press the special function button from apartment station 1)press the pedestrian door lock release button from apartment station (default) 2) press the driveway door lock release button from apartment station 3) press the call button to switchboard from apartment station 4) press the special function button from apartment station 1)press the pedestrian door lock release button from apartment station (default) 2) press the driveway door lock release button from apartment station 3) press the call button to switchboard from apartment station 4) press the special function button from apartment station 5) sending the pedestrian door lock release command from switchboard 6) sending the driveway door lock release command from switchboard 5) sending the pedestrian door lock release command from switchboard 6) sending the driveway door lock release command from switchboard 5) sending the pedestrian door lock release command from switchboard 6) sending the driveway door lock release command from switchboard CODE CODE 1 (DIP-SWITCH) (JUMPER) SCQ (JUMPER) MT CODE ON OFF ON OFF (irrelevant for events 5-6) Toggle time: ON OFF 1 8 00:00 Follow the indications provided in the instruction booklet in the "OPERATING MODE" chapter. Example 4: activation of special decoder after pressing the intercom call button of any system user. VV.017 - Special service decoder must be configured as follows: (DIP-SWITCH) 8 1 (JUMPER) (irrelevant for events 5-6) (JUMPER) Toggle time: SCQ MT 00:00 (JUMPER) Toggle time: SCQ MT 00:00 Example 5: activation of special decoder after pressing the intercom call button of any system user in riser 1. Example 6: activation of special decoder after pressing the intercom call button of user 4 in riser 1. VV.017 - Special service decoder must be configured as follows: VV.017 - Special service decoder must be configured as follows: CODE (DIP-SWITCH) 8 (irrelevant for events 5-6) Follow the indications provided in the instruction booklet in the "OPERATING MODE" chapter. CODE ON OFF 1 (DIP-SWITCH) (JUMPER) Follow the indications provided in the instruction booklet in the "OPERATING MODE" chapter. CODE ON OFF 8 ON OFF 1 (DIP-SWITCH) 8 1 (DIP-SWITCH) 8 Set a unique code on decoder with the dip-switch 1 in OFF position. Set a unique code on decoder with the dip-switch 1 in OFF position. Set a unique code on decoder with the dip-switch 1 in OFF position. Program the apartment station button to perform a direct intercom call to the decoder Program the apartment station button to perform a direct intercom call to the decoder Program the apartment station button to perform a direct intercom call to the decoder Program the event: Program the event: Program the event: intercom call sending from apartment station to special decoder intercom call sending from apartment station to special decoder (JUMPER) INSTALLATION DIAGRAMS Example 3: activation of special decoder after pressing the driveway door lock release button of user 4 in riser 1. (JUMPER) SCQ (JUMPER) SCQ (JUMPER) MT Toggle time: SCQ (JUMPER) 00:00 Follow the indications provided in the instruction booklet in the "OPERATING MODE" chapter. 50 −−−− sec.6 intercom call sending from apartment station to special decoder MT Toggle time: (JUMPER) 00:00 Follow the indications provided in the instruction booklet in the "OPERATING MODE" chapter. MT Toggle time: 00:00 Follow the indications provided in the instruction booklet in the "OPERATING MODE" chapter. 2 VOICE - Technical Manual Special decoder connection and programming with connection between door units interface and column interface Example 7: activation of special decoder after pressing the pedestrian door lock release command from switchboard. SV124-1157 VV.016 - Special service decoder must be configured as follows: Program the event: 1)press the pedestrian door lock release button from apartment station (default) 2) press the driveway door lock release button from apartment station 3) press the call button to switchboard from apartment station 4) press the special function button from apartment station 5) sending the pedestrian door lock release command from switchboard 6) sending the driveway door lock release command from switchboard CODE ON OFF 1 (DIP-SWITCH) 8 (JUMPER) (irrelevant for events 5-6) (JUMPER) Toggle time: SCQ MT 00:00 Follow the indications provided in the instruction booklet in the "OPERATING MODE" chapter. Example 8: activation of special decoder after sending special code from main outdoor station or switchboard. Example 9: activation of special decoder after sending special code from any secondary outdoor station. Example 10: activation of special decoder after sending special code from any secondary outdoor station in riser 1. VV.018 - Special service decoder must be configured as follows: VV.019 - Special service decoder must be configured as follows: VV.019 - Special service decoder must be configured as follows: Program the event: Program the event: Program the event: sending of special code from outdoor station or switchboard sending of special code from outdoor station or switchboard CODE CODE CODE ON OFF ON OFF 1 (DIP-SWITCH) (JUMPER) ON OFF 1 8 (DIP-SWITCH) 8 1 (JUMPER) (irrelevant) (JUMPER) Toggle time: 00:00 Follow the indications provided in the instruction booklet in the "OPERATING MODE" chapter. 8 SCQ (JUMPER) MT (DIP-SWITCH) (JUMPER) SCQ SCQ MT sending of special code from outdoor station or switchboard Toggle time: 00:00 Follow the indications provided in the instruction booklet in the "OPERATING MODE" chapter. (JUMPER) MT Toggle time: 00:00 Follow the indications provided in the instruction booklet in the "OPERATING MODE" chapter. PROGRAMMING ALARM SIGNALS INSTALLATION DIAGRAMS Example 11: panic alarm signal to switchboard by pressing the remote button (PC) and activation of special decoder. VV.020 - Special service decoder must be configured as follows: CODE ON OFF 1 (DIP-SWITCH) 8 Set apartment station code in the riser decoder and set the dip-switch 1 to ON. Follow the indications provided in the instruction booklet in the "OPERATING MODE" chapter. 2 VOICE - Technical Manual sec.6 −−−− 51 Connection of N columns with video door phones and door phones with 8 distributors max. to one riser of the door units interface SV124-1164 RISER 1 BACKBONE “1” Ref.1083/55 Ref.1072/59 TO FOLLOWING DISTRIBUTORS BACKBONE “2” AS BACKBONE “1” BACKBONE “3” AS BACKBONE “1” BACKBONE “4” AS BACKBONE “1” Ref.1083/50 Ref.1083/55 Ref.1072/59 EQUIPMENT/CONNECTIONS AS MAIN VIDEO OUTDOOR STATION “A” Ref.1083/20 AS RISER 1 SECONDARY VIDEO OUTDOOR STATION To following modules AS RISER 1 AS RISER 1 Ref.1083/55 Ref.1083/55 Max 4 expansions 16 users AS RISER 1 Name tag lighting DO NOT CONNECT AS RISER 1 AS RISER 1 AS RISER 1 DO NOT CONNECT INSTALLATION DIAGRAMS DO NOT CONNECT Lock release Ref.1083/75 MAIN VIDEO OUTDOOR STATION EQUIPMENT/CONNECTIONS AS MAIN VIDEO OUTDOOR STATION “A” Ref.1083/20 Name tag lighting Ref.9000/230 SECONDARY VIDEO OUTDOOR STATION 52 −−−− sec.6 Ref.1083/20 2 VOICE - Technical Manual Connection of N columns with video door phones and door phones with 8 distributors max. to one riser of the door units interface SV124-1164 AS RISER 1 AS RISER 1 AS RISER 1 AS RISER 1 Ref.1083/55 Ref.1083/55 TO DISTRIBUTORS 3, 4, 5 AND 6 RISERS AS DISTRIBUTOR 1 AS RISER 1 AS RISER 1 AS RISER 1 INSTALLATION DIAGRAMS AS RISER 1 DIAGRAM NOTES C4.013 VD.007 VV.001 2 VOICE - Technical Manual VV.002 VV.007 VV.008 VX.006 VX.008 VX.014 VX.037 sec.6 −−−− 53 Connection of N columns with video door phones and door phones with 4 distributors max. to one riser of the door units interface SV124-1165 RISER 1A BACKBONE “1” Ref.1083/55 Ref.1072/59 TO FOLLOWING DISTRIBUTORS BACKBONE “2” AS BACKBONE “1” BACKBONE “4” AS BACKBONE “1” BACKBONE “3” AS BACKBONE “1” Ref.1083/55 Ref.1083/50 Ref.1072/59 EQUIPMENT/CONNECTIONS AS MAIN VIDEO OUTDOOR STATION “A” Ref.1083/20 SECONDARY VIDEO OUTDOOR STATION AS RISER 1A AND 1B AS RISER 1 AND 2 AS RISER 1 AND 2 Ref.1083/55 To following modules Ref.1083/55 Max 4 expansions 16 users AS RISER 1A AND 1B AS RISER 1A AND 1B AS RISER 1 AND 2 AS RISER 1 AND 2 Name tag lighting DO NOT CONNECT DO NOT CONNECT INSTALLATION DIAGRAMS DO NOT CONNECT Lock release Ref.1083/75 MAIN VIDEO OUTDOOR STATION EQUIPMENT/CONNECTIONS AS MAIN VIDEO OUTDOOR STATION “A” Ref.1083/20 Ref.1083/20 MAIN VIDEO OUTDOOR STATION 54 −−−− sec.6 Ref.9000/230 2 VOICE - Technical Manual Connection of N columns with video door phones and door phones with 4 distributors max. to one riser of the door units interface SV124-1165 RISER 1B AS RISER 1A BACKBONE “5” AS BACKBONE “1” BACKBONE “8” AS BACKBONE “1” BACKBONE “7” AS BACKBONE “1” BACKBONE “6” AS BACKBONE “1” EQUIPMENT/CONNECTIONS AS MAIN VIDEO OUTDOOR STATION “A” Ref.1083/50 SECONDARY VIDEO OUTDOOR STATION Ref.1083/20 AS RISER 1A AND 1B AS RISER 1A AND 1B AS RISER 1 AND 2 AS RISER 1 AND 2 Ref.1083/55 AS RISER 1A AND 1B AS RISER 1 AND 2 AS RISER 1 AND 2 INSTALLATION DIAGRAMS AS RISER 1A AND 1B Ref.1083/55 DIAGRAM NOTES C4.013 VD.007 VV.001 2 VOICE - Technical Manual VV.002 VV.007 VV.008 VX.006 VX.008 VX.014 VX.021 VX.037 sec.6 −−−− 55 Replacement of a video door phone call station with a door phone one equipped with an additional camera SV124-1158 TO THE SYSTEM Lock release TO THE SYSTEM INSTALLATION DIAGRAMS Plug Mains Lock release DIAGRAM NOTES VV.002 VX.006 56 −−−− sec.6 VX.008 2 VOICE - Technical Manual