Preview only show first 10 pages with watermark. For full document please download

Installation Guide

   EMBED


Share

Transcript

www.elementalled.com [email protected] 877.490.4897 ® LED LIGHT GUIDE PANEL INSTALLATION GUIDE WARNING DO NOT CONNECT DIRECTLY TO HIGH VOLTAGE POWER! Read all warnings and installation instructions thoroughly. Safety & Warnings • Install in accordance with the National Electric Code, and local regulations. • This product is intended to be installed and serviced by a qualified, licensed electrician. • Only install with a Class 2 DC Constant Voltage LED driver. • Only use copper wiring. • This product is not suitable for outdoor/wet location environments. • Do not install if product has any visible damage. • Do not modify or disassemble this product beyond instructions or the warranty will be void. Quick Specs Included Models Input Voltage Varies per LED Light Guide Panel Indoor/Dry Location Models Ambient Temperature † -4°F ~ 140°F (-20°C ~ 60°C) EL-LG-PAN †† Do not install product in an environment outside the listed ambient temperature. 12VDC 24VDC DIMMABLE DRY LOCATION Installation Handle panels larger than 24 x 36 in. vertically or frame may bend. Prior to installation, ensure all components are a compatible system. Configure and pre-test your LED system prior to permanent installation to ensure all components are operating correctly. Plug-in-Adapter Systems Hard-Wired Systems Utilize DC plug accessories to build your system. Follow steps 1-5 for all hard-wired systems. AC Power 50/60Hz Class 2 Low Voltage Plug-In Adapter (Driver) Turn OFF High Voltage AC Power at the main breaker. Inline Accessory§ WARNING (Extensions, splitters, controls, etc.) Shock Hazard. May result in serious injury or death. Insertion points for DC accessories LED Light Guide Panels DC Splitter Plug Continue to page 2. IG021216-2.0 [email protected] 1 OF 4 www.elementalled.com www.elementalled.com [email protected] 877.490.4897 ® LED LIGHT GUIDE PANEL INSTALLATION GUIDE Installation Continued 2 3 Continued Determine locations to install 3 main components. Refer to ‘System Diagrams.’ Multiple Panel Mounting: 1) Compatible Control L V+ N V- To achieve even light distribution, install a diffuser or place the graphic image a reasonable distance from the panel. Distance will vary as each panel is built to custom specifications. 2) Driver 3) Fixture iFIT Panels 3 Front Profile Mount LED Light Guide Panel to surface. Option 1 - Mount with mirror clips: (must be purchased at local hardware store). Measure thickness of light panel and purchase clips with matching depth. Mount panel just like mounting a mirror. Option 2 - Mount with pre-drilled holes: DO NOT drill additional holes or the warranty will be void. Purchase mounting screws at local hardware store. Display Graphic Side Profile 4 Attach LED driver and additional components to light panel(s). Refer to ‘System Diagrams’. 5 Verify connections, and Turn Main Power ON at Breaker. Pre-drilled hole Mounting hardware (not included) Option 1 Option 2 Turn OFF main power at breaker and verify all connections. Review ‘System Diagrams’, ‘Troubleshooting’, and component installation guides. IG021216-2.0 [email protected] 2 OF 4 www.elementalled.com www.elementalled.com [email protected] 877.490.4897 ® LED LIGHT GUIDE PANEL INSTALLATION GUIDE System Diagrams The following diagrams are provided as example system designs. Always review each component installation guide for detailed and up-to-date wiring instructions. Install in accordance with NEC and local regulations. REIGN™ 12-24V Dimmer System L N V+ V− G* AC Power 50/60Hz Install applicable wire gauge / type L N Class 2 Low Voltage Driver** Installed in Junction Box‡ 120VAC On/Off Switch VLED Light Guide Panels‡‡ V+ V- L L N N Input V− G* AC Power 50/60Hz V+ (Red) V+ Output V- (Black) Class 2 Low Voltage Driver*** Installed in Junction Box‡ REIGN 12-24V Dimmer**** V- LED Light Guide Panels‡‡ V+ V- V+ Install applicable wire gauge / type ON/OFF System V+ OMNIDRIVE™ Electronic Dimmable Driver System Magnetic Dimmable Driver System Compatible Dimming Control or On/Off Switch ^ OMNIDRIVE Dimmable Driver ^^ N N V+ N V− GND* Some dimmers may require an additional neutral wire connection. VLED Light Guide Panels‡‡ N L AC Power 50/60Hz V+ V- L (Black) N (White) V+ (Red) V- (Blue) GND (Green) VLED Light Guide Panels‡‡ V+ VV+ V+ RGB Color Changing System Install applicable wire gauge / type AC Power 50/60Hz L Install applicable wire gauge / type L Magnetic Dimmable Driver†† 120VAC Magnetic Low Voltage Dimmer† DMX System Not Pictured. L N V+ V+ V− V− G* RUN AC Power 50/60Hz L N Class 2 Low Voltage Driver*** Installed in Junction Box‡ V+ B G R RGB Color Controller**** The LED Light Guide Panel is compatible with all of our RGB and DMX controller systems. See each controller installation guide for additional system diagrams. SYSTEM DIAGRAM NOTES LED Light Guide Panels‡‡ (color-changing model) See next page for important notes pertaining to each system diagram. IG021216-2.0 [email protected] 3 OF 4 www.elementalled.com www.elementalled.com [email protected] 877.490.4897 ® LED LIGHT GUIDE PANEL INSTALLATION GUIDE System Diagram Notes * Driver may not require a framed ground connection. Refer to driver specifications for additional information. ** Install a compatible Class 2 constant voltage driver. Refer to each driver specification sheet for full power ratings & load deratings. *** Install a Class 2 constant voltage driver compatible with a low voltage PWM controller/dimmer switch. Refer to each driver specification sheet for full power ratings & load deratings. **** Determine the number of low voltage outputs of the driver when installing multiple PWM controllers/dimmer switches. No more than one PWM controller/dimmer switch can be attached to a single output of the driver. ^ Install a compatible dimming control or switch. See the ‘OMNIDRIVE Compatibility List’ for compatible dimming controls. See the dimming control manufacturer installation guide for complete wiring instructions. ^^ Ensure to load OMNIDRIVE driver at least 60% the labeled load for proper dimming performance (required for dimmable installations only). † Install a compatible magnetic low voltage dimmer switch. See the MFG installation guide for complete wiring instructions. †† Magnetic dimmable drivers require a compatible magnetic low voltage dimmer switch to supply the driver and fixture with appropriate input voltage. Do not test or install directly connected to an AC power source or to an On/Off switch. Refer to each driver specification sheet for full power ratings & load deratings. See dimming control manufacturer specifications for minimum load recommendations. ‡ Refer to driver or controller specifications for a compatible junction box. ‡‡ See fixture specifications for maximum series run limits. § See in-line accessories specifications for maximum amperage ratings. §§ See fixture accessories for a compatible adapter connector. Troubleshooting Fixture does not illuminate • Ensure the system is wired correctly and polarities are correct. • Ensure the driver and fixture have the same voltage specifications (12V & 12V, or 24V & 24V). Shift in brightness / kelvin • Ensure appropriate gauge wire is installed between driver & fixture. Uneven light distribution when installing multiple panels (dim areas, halo effects, etc.) • When installing multiple panels, the display graphic must be placed a reasonable distance from the light panels to achieve even light distribution. Fixture does not dim • Ensure a compatible dimming control is installed and wired correctly. See driver installation guide for compatible dimming controls. Fixture is quickly flashing or flickering • Verify a compatible dimming control is installed. • Ensure all connections are properly secured. • Ensure fixture is receiving the correct input voltage. Fixture is slowly flashing • Ensure driver is not overloaded. An overloaded driver will cause the internal auto-reset to trip repeatedly. Installation Trips Main Breaker • Check wiring for short circuit. If breaker continues to trip there may be a short in the driver. Call customer support for a replacement driver. Additional Resources Visit the online product page at www.elementalled.com for additional product specifications & warranty information: • LED Light Guide Panel Specification & Sales Sheet For full specifications. • Voltage Drop Charts Use to specify appropriate wire gauge for installation. Available on the ‘Learn’ page at www.elementalled.com. QUESTIONS? Visit www.elementalled.com or contact Customer Support at [email protected] or 877.490.4897 Monday through Friday, 7:00am - 5:00pm PST. IG021216-2.0 [email protected] 4 OF 4 www.elementalled.com